Você está na página 1de 28

OVERWIER

WCDMA ERICSSON
AGENDA

Viso geral da rede


Descrio dos equipamentos (HW)
Teste de transmisso IP e ATM entre RNC x Tellabs x BTS (VLAN, PING,
TRACE, PDH, SONET, LOOP)
Testes de sincronismo NodeB x RNC (Alarmes de IP Synch Ref)
Verificao de trfego / usurios alocados
VSWR (alarmes, testes, configurao)
RETs verificao do status se esta enable ou disable
Testes / configurao NTP Server
AGENDA

Verificao de placas com defeitos, mal conectadas (comandos CAB,


CABX, INVH, INVHR)
Verificao / SET de CV
Verificao de frequncia e potncia (NodeB e RNC)
Verificar status de licena do site (definitiva, emergencial)
Verificar status do site RNC (transmisso, VLAN, setores, interface
O&M)
Verificar status de TX do site (IUB, NBAP e Packet ABIS) se o site IP
ou ATM
Verificao de status das portas LAN (GIGA, FAST e NEGOCIAO)
VISO GERAL DA REDE (WCDMA
RAN)
External
Core Network Management
System

Radio Access Iu Mun


Network
Mur
OSS-RC
Iur Mut TEMS
RNC/
RNC/ EVO
Network
RXI EVO Mub
Iub Management
Environment
Uu

NodeB User Equipment


NodeB

NodeB
Iub ATM based
User Equipment
RBS 6601 HW
ARCHITECTURE

Foot print: 350mm x 19


Height: 1.5U (66,25mm)
Weight (fully equipped): 10kg
Power System: -48VDC
Capacity: Up to 2 Digital Units
Up to 6 RRUs (connected)
Power Cons AC (max): 415W
Heat generation (max): 405W
Temperature Range: 5C to +50C
Radio configurations (max)
WCDMA: 3x2 MIMO 2x2
(2 6601 can be combined to 3x4)
for DUL (GSM) 3x8-TRX
RBS 6601 TECHNICAL SPECIFICATIONS

Main unit supporting WCDMA

Main unit supporting GSM and LTE


DIGITAL UNITS WCDMA
(DUW)
Main Capacity characteristics Units

DUW variant DUW10 DUW20 DUW30 DUW11 DUW31 DUW41


6 6 6 12 12 12 Units
Max. Nr. of IQ Streams D
128 384 768 192 768 768 Units
Max. number of CE DL

128/192 (EUL) 384/576 (EUL) 512/768 (EUL) 128/192 (EUL) 512/768 (EUL) 768/1152 (EUL) Units
Max. number of CE UL
1.25/2.5 1.25/2.5 1.25/2.5 1.25/2.5/5/10 1.25/2.5/5/10 1.25/2.5/5/10 Gbps
Supported RI Connections
350 350 350 350 350 350 mm
Height
62 62 62 31 62 62 mm
Width
280 280 280 280 280 280 mm
Depth
< 4.5 < 4.5 < 4.5 < 2.7 < 4.5 < 4.5 kg
Weight
DIGITAL UNITS WCDMA CONTINUED

current
selection of
Swisscom
DUW Interface Description
Optical
Marking Connector Description Indicator Interface
-V48 ET20 A -48 V DC Power No -
GPS RJ-45 Global Positioning System (GPS) No External
EC RJ-45 Enclosure Control Bus (ECB) Yes Internal
AUX RJ-45 Auxiliary Bus No Internal
LMT A RJ-45 Console No Internal
Both
LMT
Local Maintenance Terminal together Yes External
LMT B RJ-45
TN A RJ-45 Transmission, Ethernet Yes External
TN B SFP Transmission, Ethernet (or STM-1) Yes External
TN C SFP Transmission, Ethernet Yes External
F/O/I - Fault / Operation / Information Yes -
! / P/ - Fault / Operation / Maintenance Yes -
ET A RJ-45 Transmission, 2xE1/T1/J1 Yes External
ET B RJ-45 Transmission, 2xE1/T1/J1 Yes External
IDL HSIO Inter DU Link No Internal
A SFP Radio Interface A Yes
B SFP Radio Interface B Yes
Internal between DU
C SFP Radio Interface C Yes and RU, electrical

D SFP Radio Interface D Yes External between DU


and RRU, optical
E SFP Radio Interface E Yes
F SFP Radio Interface F Yes
DIGITAL UNITS LTE (DUL /
DUS)

Main Capacity characteristics Units

DU variant DUL20 DUS31 (01/02) DUS41 (01/02)


2.5 2.5 /5 /10 2.5 /5 /10 Gbps
Supported RI Connections
350 350 350 mm
Height
31 31 31 mm
Width
280 280 280 mm
Depth
<3 <3 <3 kg
Weight
DUL / DUS Interface Description
Optical
Indicator
Marking Connector Description Interface
PWR ET20 A -48 V DC Power No -
GPS RJ-45 Global Positioning System (GPS) No External
EC RJ-45 Enclosure Control Bus (ECB) Yes Internal
AUX RJ-45 Auxiliary Bus No Internal
LMT A RJ-45 Console No Internal
Both
LMT
Local Maintenance Terminal together Yes External
LMT B RJ-45
TN A RJ-45 Transmission, Ethernet Yes External
TN B SFP Transmission, Ethernet (or STM-1) Yes External
TN C SFP Transmission, Ethernet Yes External
F/O/I - Fault / Operation / Information Yes -
! / P/ Fault / Operation / Maintenance Yes
- -
COMP SFP+ Transmission, Ethernet Yes External
IDL HSIO Inter DU Link No Internal
A SFP(+) Radio Interface A Yes
B SFP(+) Radio Interface B Yes Internal between
DU and RU,
C SFP(+) Radio Interface C Yes electrical

D SFP(+) Radio Interface D Yes External between


DU and RRU, optical
E SFP(+) Radio Interface E Yes
F SFP(+) Radio Interface F Yes
RADIO UNIT: INTERFACES
Power: -48 V DC

RUW RUW
Data1: CPRI Interface connection for connections to DUs
Data2: CPRI Interface connection for connections to DUs
or between RUs
Optical Indicators:
Power
Data 2
Power
Data 2
F Fault
DU
O Operational
Data 1
F
O
Data 1
F
O
I Information
I I

RFA: Transmitting/Receiving RF
TX A out TX B out
RX A in RX B in
DC power to ASC/TMA/RIU, modem data
RXA I/O
RF A
RXA I/O
RF A
RFB: (10er Versions Transmitting/)Receiving RF
DC power to ASC/TMA/RIU, modem data
RF B RF B
RXA Out RXA Out
RXA I/O: Crossconnect output external input
RXB I/O RXB I/O
RXA Out: RXA cosite output
RXB I/O: Crossconnect input RXB cosite output
RUW/RUS 01
RADIO UNIT MULTI STANDARD
Functions
RUS Multi standard radio including. clipping, PA, UL/DL
filtering, ASC/TMA/RET support
Capacity/Performance
Power Class 60W @ ARP
1 TX/RX and 1 RX branch
GSM: 1-4 carriers UL/DL with diversity
*First revision of RUW have DensiShield connector WCDMA: 1-4 carriers UL/DL with diversity
LTE: 20 MHz
60W total power DL (B7 40W)
RUW/ RUS Full operating BW, 20 MHz IBW
Power Digital RF + Ctrl
7/16"
Data 2
Frequency bands: B1 (2100 MHz), B3 (1800 MHz), B7
RF + Ctrl
7/16" (2600 MHz), B8 (900 MHz)
TX
CPRI & Gamma
Metrics
HSIO*
Data 1
QMA
RXA I/O Power consumption (W) 400 W
F
O QMA
RXA Out Power dissipation (W) 310 W
M
CPRI & Gamma Hotspots Yes
HSIO* RXB I/O
RX
QMA Airflow Front to Back
Max airflow 27 g/s
Min pressure drop 90 Pa
M
Temperature range 5 to +55
System Size (HxWxD) 8U x 62mm x 280mm
Voltage
ET 20A Power Weight <7,1 kg
RF A
RXA I/O

External Interfaces
Digital Interface Data1, Data2, 2xCPRI
RF B Antenna Interface RFA, RFB
RXA Out
RX Out RXA Out
RX In/Out RXA I/O, RXB I/O
Test LMT B (back)
-48VDC PWR
RXB I/O
Maintenance button M
MMI-LED FOM
RRUS 11 Remote RADIo Unit MS

B1 IBW-> 20 MHz POut-> 2*40W


B20 IBW-> 20 MHz POut-> 2*40W
B7 IBW-> 20 MHz POut-> 2*30W

Number of carriers -> 1-4


RBS 6000 SUPPORT
SYSTEM
Support System units:
SCU Support Control Unit
SHU Support Hub Unit
PSU Power Supply Unit
PDU Power Distribution Unit
SAU Support Alarm Unit
Climate Unit (internal FAN, optional heater, optional
external FAN)
PFU Power Filter Unit
PCF Power Connection Filter
PCU Power Connection Unit (AC or DC)
SUPPORT SYSTEM ARCHITECTURE
SCU
ECB RJ45 Minifit
4
Alarm
/Ctrl Power Fans
ECB+PowerModular10
Lamp Minfit 2 Ctrl
Ext Alarm SAU
Mini2
Door Minifit
fit 2 Tyco
Heater
RJ45 SmokeInternal
/ Alarm
Minifit
6 RJ45
Modular
10 EXT. TempSens
Microfit4
RJ45 AC from PCU AC
DC from PDU

Battery BFU
TempSensor ECB
Minifit
2 RJ45
Terminal Anderson BusBar

PCF PCU DC
TempSens
dSUB dSUB
Battery
Terminal Terminal Anderson BusBar
-48VDC
SHU
PCF RJ45 ECB
-48VDC
Terminal BusBar RJ45 RJ45
From PBC RJ45 RJ45 ECB
RJ45 RJ45
+24 VDC
PCU DC PSU DC
-48/-60 VDC ECB
Terminal Terminal IEC RJ45
BusBar
PDU Cold+
PCU AC PSU AC Tyco
prio load
AC Main load
Terminal Cable
+IEC IEC RJ45 RJ45 Tyco
Prio Load
OUTDOOR IEC BusBar BusBar Tyco
Service Out
Sys.Voltage
PCU AC PFU
AC
Terminal Terminal Terminal
INDOOR RJ45
Control path to HW Units
Primary/Secondary node The Control of the Support Systems is done
by the Primary DU via the EC Bus.
concept The distribution of the Informations is done via the SHU

-only 1 DU controls the Cabinet


Support System (primary node)
-all other DUs are secondary
nodes

Note:
In configurations equipped with two
DU there is only one EC bus cable
connected to SHU from the master
DU. Large RBS
The IDL(DUW) / ESB(DUG) cable is
connected between the master and
the slave DU, but unfortunately as well
market with primary and secondary. Small RBS

The SHU 02 01 connects


up to 16 peripheral units
to the EC bus.
The SHU is a connection
field for RS 485
communication
ALARM & FAN HANDLING
OVPs are the connection points
Relays connection for external inputs like Alarms
field of PU200 (Water, external Doors ) or E1 Lines The SAU is an alarm supervision unit
that s placed inside an outdoor RBS Power connection
or For Fangroups
01
02
1- can be placed outside an indoor RBS
2- with the help of a DF-OVP
03
04
4-

Power
05

ECB
Al1
5-
Port
Alarm

Connector
Modular
06
07
SAU
7-
08 Al2
8-
09
10
10 -
11
11 -
12
13
13 -
14
14 -
15
16 The SAU is
16 - +12V
17
17 -
connected to
UART

485
RS-
18 DC/DC +3.3V the SCU through
19
20
19 - an EC-bus cable.
20 -
21
22
22 -
23
23 -
24

The SCU 02 01 is
Other one single unit
that controls and
External supervises
Alarms up to 4 fans

DF-OVP
DUAL-STACK RBS
The Ericsson Dual Stack RBS supports both Iub over ATM
and Iub over IP transport split for different traffic types

DUW x0 01

R99 user data, synch,


PWR

O&M, Signalling
GPS
EC
AUX
LMT B

ATM
LMT A
TN B

To RNC
ET B
ET A

IP
O
M
IDL
TN A
RI F
RI E
RI D

HSPA user data


RI C
RI B
RI A
ATM Transmission with more than 4 E1s
RPMR 102 RPMR 102
TIU ports 06/3 Pin no. Signal Direction 06/3 color 4 x RJ45
With four of these Sofix cables we A1 1A IN A White 1 Pin 1
can transfer 16 E1 to the TIU: B1 1A IN B Orange 1 Pin 2
C1 1A OUT A White 1 Pin 4
D1 1A OUT B Blue 1 Pin 5
A2 1B IN A White 2 Pin 1
TR:1A-1D= 1-4 E1 B3 1B IN B Brown 2 Pin 2
TR:2A-2D= 5-8 E1 TR:1A-1D C2 1B OUT A White 2 Pin 4
TR:2A-2D D3 1B OUT B Green 2 Pin 5
TR:3A-3D= 9-12 E1 TR:3A-3D A4 1C IN A Red 3 Pin 1
TR:4A-4D
TR:4A-4D= 13-16 E1 B5 1C IN B Orange 3 Pin 2
C4 1C OUT A Red 3 Pin 4
D5 1C OUT B Blue 3 Pin 5
From the TIU we transfer this A6 1D IN A Red 4 Pin 1
B6 1D IN B Brown 4 Pin 2
16E1s via an optical cable to the C6 1D OUT A Red 4 Pin 4
DU. D6 1D OUT B Green 4 Pin 5