Escolar Documentos
Profissional Documentos
Cultura Documentos
Catálogo Furukawa
Catálogo Furukawa
Institucional
ndice
7 17
18 19 20 21 21 22 23 23 27 28 29 30
33 38 39
39 39 40 40 41 41 41 42 42 42 43 43 43 44 44 44 45 45 46 46 47 48 48 49 49 50 50 50
GigaLan Augmented
PatcH cOrD MetlIcO GIGalan auGMenteD cat.6a cOnectOr FMea BlInDaDO GIGalan auGMenteD cat.6a cOnectOr FMea GIGalan auGMenteD cat.6a caBO eletrnIcO GIGalan auGMenteD cat.6a F/utP 23aWGX4P caBO eletrnIcO GIGalan auGMenteD cat.6a u/utP 23aWG X 4P
51
51 52 52 53 54
GigaLan Categoria 6
PatcH cOrD MetlIcO F/utP GIGalan cat.6 PatcH cOrD MetlIcO u/utP GIGalan cat.6 PatcH cOrD InDustrIal F/utP GIGalan cat.6 PatcH cOrD InDustrIal u/utP GIGalan cat.6 cOnectOr FMea BlInDaDO GIGalan cat.6 cOnectOr FMea GIGalan PreMIuM cat.6 cOnectOr FMea GIGalan stanDarD cat.6 cOnectOr FMea InDustrIal BlInDaDO F/utP GIGalan cat.6 cOnectOr FMea InDustrIal u/utP GIGalan cat.6 caBO eletrnIcO BlInDaDO GIGalan cat.6 F/utP 23aWG X4P caBO eletrnIcO GIGalan cat.6 u/utP 23aWG X 4 P caBO eletrnIcO GIGalan stanDarD cat.6 u/utP 24aWG X 4 P caBO eletrnIcO GIGalan InDOOr/OutDOOr cat.6 u/utP 23aWGX4P caBO eletrnIcO GIGalan InDustrIal cat.6 F/utP 23aWG X4P caBO eletrnIcO GIGalan InDustrIal cat.6 u/utP 23aWG X4P taBela De PerFOrMance Para caBOs eletrnIcOs cat. 6 PatcH Panel GIGalan cat.6 PatcH Panel GIGalan stanDarD cat.6
55
55 56 57 58 59 60 61 61 62 63 64 64 65 66 66 67 68 69
MultiLan Categoria 5e
PatcH cOrD MetlIcO F/utP MultIlan cat.5e PatcH cOrD MetlIcO u/utP MultIlan cat.5e PatcH cOrD InDustrIal F/utP MultIlan cat.5e PatcH cOrD InDustrIal u/utP MultIlan cat.5e cOnectOr FMea BlInDaDO MultIlan cat.5e cOnectOr FMea MultIlan PreMIuM cat.5e cOnectOr FMea MultIlan stanDarD cat.5e cOnectOr FMea InDustrIal BlInDaDO F/utP MultIlan cat.5e cOnectOr FMea InDustrIal u/utP MultIlan cat.5e caBO eletrnIcO BlInDaDO MultIlan cat.5e F/utP 24aWGX4P caBO eletrnIcO MultIlan cat.5e u/utP 24aWGX4P caBO eletrnIcO MultIlan cat.5e u/utP 24aWGX25P caBO eletrnIcO BlInDaDO MultIlan InDOOr/OutDOOr cat.5e F/utP 24aWGX4P caBO eletrnIcO MultIlan InDOOr/OutDOOr cat.5e u/utP 24aWGX4P caBO eletrnIcO MultIlan InDustrIal cat.5e F/utP 24aWGX4P taBela De PerFOrMance Para caBOs eletrnIcOs cat. 5e caBO eletrnIcO MultIlan InDustrIal cat.5e u/utP 24aWGX4P PatcH Panel MultIlan cat.5e PatcH Panel MultIlan stanDarD cat.5e
70
70 71 72 73 74 75 76 76 77 78 79 79 80 81 81 82 82 83 84
Fisaflex
vOIce Panel cat.3 PaInel De cOneXO 110IDc BlOcO De cOneXO 110IDc KIt BlOcO De cOneXO 110IDc cOnectOr FMea 110IDc (cOnnectInG BlOcK) PatcH cOrD 110IDc u/utP FIsaFleX cat.6 PatcH cOrD 110IDc u/utP FIsaFleX cat.5e PatcH cOrD vOz MetlIcO u/utP POntO De telecOMunIcaO 110IDc caBO eletrnIcO FIslan cat.3
85
85 86 86 87 87 88 89 90 90 91
Fisacesso
racK 2P aBertO 19 45u ItMaX racK 4P aBertO 19 45u ItMaX racK aBertO 19 racK aBertO De PareDe (BracKet artIculaDO) caIXa - centrO De DIstrIBuIO MultIMDIa (cDM) GuIa vertIcal 200MM ItMaX GuIa vertIcal entre racKs 315MM ItMaX taMPa lateral ItMaX GuIa De caBOs vertIcal FecHaDO 140MM Face sIMPles GuIa De caBOs vertIcal GuIa HOrIzOntal 2u ItMaX GuIa HOrIzOntal 4u ItMaX GuIa De caBOs HOrIzOntal FecHaDO alta DensIDaDe GuIa De caBOs HOrIzOntal aBertO alta DensIDaDe GuIa De caBOs HOrIzOntal FecHaDO PlstIcO GuIa De caBOs HOrIzOntal FecHaDO GuIa De caBOs HOrIzOntal aBertO PerFuraDO GuIa De caBOs HOrIzOntal zerO-u BanDeja suPerIOr e InFerIOr ItMaX GuIa De caBOs suPerIOr GuIa De caBOs InFerIOr GuIa De caBOs traseIrO Barra De aterraMentO ItMaX acOMODaDOr raDIal PlstIcO ItMaX PrateleIras Para racK GraMPO Para OrGanIzaO vertIcal PaInel De FecHaMentO anGular PaInel De FecHaMentO MDulO Para DaDOs cat.6 8 POrtas - cDM MDulO Para DaDOs cat.5e 8 POrtas - cDM MDulO DIstrIBuIO De vDeO vertIcal - cDM MDulO telecOM seGurana - cDM MDulO DIstrIBuIO De uDIO stereO 6 aMBIentes - cDM MDulO telecOM 8 POrtas - cDM MDulO eXPansO telecOM 8 POrtas - cDM Placa De MOntaGeM - cDM rGua MODular - cDM PatcH Panel anGular 24P e 48P BlInDaDO PatcH Panel anGular 24P e 48P PatcH Panel DescarreGaDO BlInDaDO cOM cOnes PatcH Panel DescarreGaDO 24P cOM cOnes PatcH Panel MODular lGX
92
92 92 93 93 93 94 94 94 95 95 95 96 96 96 97 97 97 98 98 98 99 99 99 100 100 100 101 101 101 101 102 102 103 103 103 104 104 104 105 105 106 106
PatcH Panel DescarreGaDO alta DensIDaDe POntO De cOnsOlIDaO alta DensIDaDe - zDa POntO De cOnsOlIDaO 24 POsIes POntO De cOnsOlIDaO 12 POsIes BlInDaDO caIXa De aParente InDustrIal IP67 caIXa aParente MultIMDIa caIXa aParente tOMaDa aParente esPelHO anGular esPelHO InDustrIal IP67 esPelHO PlanO esPelHO MODular MDulO Para esPelHO KIt Placa Para aDaPtaDOres rj-45 lGX cOnjuntO aDaPtaDOr cOne De IDentIFIcaO Base Para trIlHO DIn aDaPtaDOr Para trIlHO DIn
106 107 107 108 108 109 109 110 110 111 111 111 112 112 113 113 114 114
PatchView
Master Master eXPanDer eXPanDer scanner MInI-scanner cOntrOlaDOr InDIcaDOr Para racK cOntrOlaDOr De seGurana cOntrOl PaD caBO rOunD Flat sOFtWare De GerencIaMentO PatcHvIeW aPlIcaes OPcIOnaIs PatcH Panel GerencIvel MODular PatcH Panel GerencIvel MODular BlInDaDO PatcH Panel GerencIvel cat.6 48P 2u anGular PatcH Panel GerencIvel alta DensIDaDe cat.6 PatcH Panel GerencIvel cat.6 DIstrIBuIDOr InternO PtIcO (DIO) GerencIvel DIO GerencIvel lc DuPleX/MPO 48F 24P 1u DIO GerencIvel lc DuPleX 48F 24P 1u PatcH cOrD IntelIGente sMart cOnnect cat.6a s/FtP PatcH cOrD IntelIGente sMart cOnnect cat.6a u/FtP PatcH cOrD IntelIGente sMart cOnnect cat.6 u/utP PatcH cOrD IntelIGente cat.6 u/utP cOrDO PtIcO IntelIGente
115
115 115 116 116 117 117 118 118 118 119 119 120 120 121 121 121 122 122 122 123 123 124 124 125
FBS
arMrIO OrBItal arMrIO trIBOX DGOI - DIstrIBuIDOr Geral PtIcO InternO MDulO De terMInaO lGX OFs GraMPO Para caBOs lGX OFs MDulO De eMenDa lGX BanDeja De eMenDa lGX OFs DIO Bt48
126
126 126 127 127 127 128 128 128
caIXa De DIstrIBuIO Interna PtIca - cDOI POntO De terMInaO PtIca rOseta PtIca sPlItters FBt e Plc sPlItter DesBalanceaDO sPlItters 2Xn sPlItters cOnectOrIzaDOs FIltrOs WDM (WavelenGtH DIvIsIOn MultIPleXInG) GePOn stanDarD - cHassIs e cartO De InterFace GePOn stanDarD - Onu GePOn PreMIuM - cHassIs Olt e cartO De InterFace (PIF) GePOn PreMIuM - Onu DaDOs GePOn PreMIuM - Onu DaDOs InDustrIal GePOn PreMIuM - Onu sFP GePOn PreMIuM - Onu eXtensOr
129 129 130 130 131 131 132 132 133 134 135 136 137 137 138
Cabos pticos
caBO PtIcO FIBer-lan InDOOr/OutDOOr caBO PtIcO FIBer-lan-ar caBO PtIcO FIs-OPtIc-DG caBO PtIcO OPtIc-lan caBO PtIcO OPtIc-lan-ar (PFv) caBO PtIcO OPtIc-lan-ar caBO PtIcO De terMInaO InternO/eXternO caBO PtIcO DrOP FIG.8 FttH caBO PtIcO DrOP FIs-OPtIc FttH caBO PtIcO DIeltrIcO autOssustentaDO cFOa-as80 MInI-ra FttH caBO PtIcO FIBer-lan InDOOr caBO PtIcO sIMPluslan caBO PtIcO InternO cOrDO PtIcO caBO PtIcO DIeltrIcO autOssustentaDO ncleO secO caBO PtIcO DIeltrIcO autOssustentaDO ncleO GeleaDO caBO PtIcO DIeltrIcO autO-sustentaDO Para lOnGOs vOs caBO PtIcO DIeltrIcO autO-sustentaDO as120-ra caBO PtIcO FIs-OPtIc-as caBO PtIcO DIeltrIcO Para DutOs ncleO secO caBO PtIcO DIeltrIcO Para DutOs ncleO GeleaDO caBO PtIcO DIeltrIcO Para DutOs cOM PrOteO cOntra rOeDOres - PFv caBO PtIcO Para DutOs cOM PrOteO MetlIca cOntra rOeDOres caBO PtIcO DIretaMente enterraDO cOM PrOteO MetlIca cOntra rOeDOres caBO PtIcO DIeltrIcO DIretaMente enterraDO caBO PtIcO DIeltrIcO DIretaMente enterraDO cOM PrOteO cOntra rOeDOres - PFv caBO PtIcO DIeltrIcO DIretaMente enterraDO cOM PrOteO cOntra rOeDOres - PPu caBO PtIcO DIeltrIcO cOM DutO nOMenclatura aBnt
139
139 140 141 142 143 144 145 146 147 148 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167
168
caBO teleFnIcO MetlIcO Fast-cIt 168 caBO teleFnIcO MetlIcO Fast-cIt XDsl 40MHz 169 caBO teleFnIcO MetlIcO Fast-cIt XDsl 8,5MHz 169 caBO teleFnIcO MetlIcO ctP-aPl-as 170 caBO teleFnIcO MetlIcO cce-aPl 171 caBO teleFnIcO MetlIcO cce-aPl-G 171 caBO teleFnIcO HBrIDO cHP-aPl-XDsl-40MHz 172 caBO teleFnIcO HBrIDO cHP-aPl-XDsl-8,5MHz 172 caBO teleFnIcO MetlIcO ctP-aPl 173 caBO teleFnIcO MetlIcO ctP-aPl-XDsl-40MHz 174 caBO teleFnIcO MetlIcO ctP-aPl-XDsl-40MHz 174 caBO teleFnIcO MetlIcO ctP-aPl-G 175 caBO teleFnIcO MetlIcO ctP-aPl-G-XDsl 40MHz 176 caBO teleFnIcO MetlIcO ctP-aPl-G-XDsl 8MHz 176 caBO teleFnIcO MetlIcO cts-aPl-G 177 caBO teleFnIcO MetlIcO cts-aPl-G-XDsl-40 MHz 178 caBO teleFnIcO MetlIcO cts-aPl-G-XDsl-8 MHz 178 caracterstIcas eltrIcas 179 caBO teleFnIcO MetlIcO ctP-aPl-sn 179 FaMlIa De caBOs Para transMIsses eM BanDa larGa (valOres tPIcOs) 180 cDIGO De cOres 180 FOrMaes cOncntrIcas 180 FOrMaes MltIPlas 180 IDentIFIcaO DOs Pares eXtras 181 QuantIDaDe De Pares PIlOtO (QuanDO eXIstIr) e Pares eXtras 181 FatOres De cOrrees e clculO De sOMa De POtncIa De DIaFOnIa (POWer suM) 182
Normas
183
Glossrio
191
Institucional
Liderana
1974 1977
1982
No seria nenhum exagero dizer que a histria da fabricao de cabos no Brasil comeou h mais de 35 anos, com o investimento feito pela Furukawa Industrial S.A. Produtos Eltricos no pas. Parte do Grupo Furukawa e destaque no segmento de telecomunicaes, a empresa iniciou suas atividades com a fabricao de cabos, e hoje possui conhecimento e desenvolvimento suficientes para oferecer solues completas, adaptadas s mais diversas necessidades para Infraestrutura de Telecomunicaes e TI - Tecnologia da Informao. Em todo este tempo, os cabos da Furukawa acompanharam e conduziram grandes avanos na rea de TI. Muitos destes avanos partiram de uma estrutura reconhecida hoje como um Centro de Excelncia para a Amrica Latina na fabricao de cabos pticos e metlicos a Unidade Industrial de Curitiba. Na fbrica, alm do compromisso com o desenvolvimento de novos produtos, existe a preocupao constante com o investimento em pesquisa, de forma tica e transparente. dessa maneira que a Furukawa consegue oferecer sempre produtos de qualidade, que respeitam o meio ambiente e contribuem para o seu desenvolvimento.
Cabos pticos
1997
1998
1999 2001
Loja Eletrnica
2002 2003
Mercado Externo
2004 2006
2007 2008
2009
2010
10
Pesquisa e Desenvolvimento
Laboratrio Component Level
Campo de Testes
Neste ambiente so reproduzidas as reais condies de instalao de cabos e acessrios, com informaes importantes sobre suas caractersticas, aplicabilidade e comportamento. Tudo isso torna possvel antecipar e corrigir possveis restries das tecnologias, garantindo a sua eficcia e conformidade com normas locais e internacionais antes do lanamento no mercado.
Garantia Estendida
Qualidade Comprovada
Todos os certificados nacionais e internacionais conquistados pela Furukawa so resultado do comprometimento com uma filosofia: para se obter um produto final de excelncia reconhecida, preciso dedicar ateno qualidade em todas as etapas do processo. Desde o momento de obteno da matria-prima, passando pelo manuseio e produo, na Furukawa a qualidade um fator fundamental. Este compromisso tambm comprovado pelos mais importantes certificados para produtos e meio ambiente, conferidos pela UL - Underwriters Laboratories, ETL e Anatel.
Logstica
Cuba
Portugal
Espanha
Ecuador
Paraguai Chile
Argentina
Uruguai
Centro de Excelncia Mundial para atender a Amrica Latina Capacidade Industrial em Escala 2 Centros de Distribuio 28 Distribuidores Autorizados Integradores Credenciados Gerentes Regionais e Engenheiros de Suporte Centros de Treinamento
Escritrio Regional Planta Industrial Distribuidores Autorizados Integradores Credenciados Centro de Treinamento
Brasil 0800 41 21 00 | Argentina 0800 800 9701 | Bolvia 800 10 2222 5445 | Chile 123 00209395 | Colmbia 01800 518 1160 Paraguai 00 812 800 5446 | Peru 0800 54089 | Uruguai 0004 019 0337 | Venezuela 0800 1008511
Filiao
A Furukawa tambm tem participao ativa nos principais rgos e comits da rea.
11
12
www.furukawa.com.br
Treinamento
Responsabilidade Sociambiental
Abrir caminho para a informao atravs da tecnologia, protegendo o meio ambiente, uma das filosofias na qual se fundamenta o trabalho da Furukawa. Prova disso o Certificado ISO 14001:2004 de Gesto Ambiental, conferido pela UL Underwriters Laboratories do Brasil - Unidade Industrial de Curitiba, no Paran. Ele refora o compromisso adotado pela empresa junto ao planeta, com o desenvolvimento de aes responsveis e produtos ecologicamente corretos. Bons exemplos so a reciclagem interna de resduos e os cabos Lead Free. Livres de metais pesados, os cabos LSZH (Low Smoke Zero Halogen) usam componentes sem halognios, o que contribui para a baixa emisso de gases txicos e fumaa e influencia diretamente na conservao do meio ambiente.
Diretiva RoHS
A Diretiva Europia RoHS restringe a utilizao de determinadas substncias nocivas, fomenta a reutilizao dos equipamentos e determina uma gesto adequada, com o objetivo de melhorar a eficcia da proteo ambiental, reduzir a quantidade de resduos industriais e a periculosidade dos componentes. Apesar de no existir uma legislao restritiva como a Diretiva RoHS na Amrica Latina, a Furukawa j implantou, desde 2007, esse modelo como padro para toda sua linha de produtos de cabeamento estruturado.
14
Responsabilidade Social
O compromisso da Furukawa no est unicamente traado na direo da evoluo da tecnologia. Projetos que contribuem para a evoluo das pessoas, com o objetivo de ajudar a tornar o Brasil um pas melhor, tambm recebem ateno especial na empresa. Atravs da interao com a comunidade local, o incentivo a aes voluntrias dos colaboradores e campanhas sociais - como doao de sangue, roupas e medula ssea - a Furukawa reafirma seu compromisso com o progresso, mostrando que a evoluo e o futuro passam pelos nossos cabos, mas vo muito alm deles. Conhea alguns programas e atitudes da Furukawa: O programa Formando Crianas para o Futuro desenvolve o potencial da criana e da cidadania em diversas comunidades. O projeto de Incluso Digital da Comunidade j entregou diversos computadores para a comunidade carente vizinha unidade de Curitiba, no Paran. Bolsas de estudos para vrios pblicos relacionados Furukawa e a comunidade onde ela est inserida. Programa Menor Aprendiz. Atravs do Programa Vamos Correr, os colaboradores recebem incentivo e treinamento para participarem de corridas e maratonas. Patrocnio a atletas. Ginstica Laboral.
15
16
17
18
Tecnologia
Fibra ptica
O cabeamento ptico perfeito para quem procura solues que ofeream alta qualidade e grande variedade de protocolos compatveis. Entre eles, o mais popular padro Ethernet, no qual a tecnologia ptica oferece uma performance melhor em grandes distncias e para elevadas taxas de transmisso. Uma performance que supera a do tradicional cabeamento metlico e depende nica e exclusivamente do tipo de fibra a ser utilizada nos produtos que compem a rede. A instalao em redes locais seguem os mesmos requisitos das normas para edifcios comerciais, Data Center ou residncias. A tabela abaixo mostra os tipos de fibras multimodo (MM) disponveis considerando as aplicaes necessrias da rede e o tamanho de suas taxas de transmisso:
275 m
320 m
10 Gbps
OM4
LaserWave 550
550 m
10 Gbps
19
20
Par Metlico
O EIA/TIA 568, de 1991, foi o primeiro padro americano para os sistemas de cabeamento estruturado. Em 1995, o padro sofreu a primeira reviso e passou a demominar-se EIA/TIA 568 A, e em maio de 2001 a segunda, transformando-se em 568 B. Uma nova reviso est em vigor e recebeu a nomenclatura EIA/TIA 568 C. Todas estas normas foram baseadas no padro ISO/IEC 11801, revisado em 2002. Estes padres tem como objetivo prover um sistema de cabeamento flexvel e confivel,capaz de ser utilizado por diversos equipamentos de diversos fabricantes. Outro diferencial a fcil expanso de uma rede j existente.
CAT.5e CAT.6
100 MHz
1 Gbps
1 Gbps
CAT.6A
10 Gbps
Categoria 6A
21
22
No mundo, os sistemas de gerenciamento de camada fsica esto presentes em empresas que necessitam de segurana total no ambiente corporativo como instituies financeiras e Data Centers.
Solues Furukawa
Alta Disponibilidade
Modularidade
Performance
Gerenciamento Segurana
Mais eficincia na utilizao do seu espao fsico, melhorando a dissipao de calor e reduzindo o consumo de energia.
23
24
O mais importante que seja escolhido um cabeamento capaz de suportar as novas tecnologias e servios futuros, e no somente o cumprimento da demanda presente da rede.
Optar por um produto que oferea o melhor benefcio a longo prazo, pois a construo fsica de um Data Center s se d uma nica vez; Considerar um produto que se adeqe infra-estrutura existente ou planejada e que no oferea um aumento expressivo nos custos, caso sejam necessrias algumas modificaes de dutos ou eletrocalhas; Estudar antecipadamente as performances dos produtos, verificando se os mesmos possuem certificaes em laboratrios independentes e compatibilidade com os demais acessrios e equipamentos da rede; Atentar para o grau de flamabilidade e emisso de gases txicos dos cabos, para garantir a segurana das pessoas e dos equipamentos; Verificar se a tecnologia aplicada aos cabos tambm se estende aos equipamentos ativos e seus mdulos de transmisso; Estar seguro que a tecnologia selecionada est prevista na norma, para que esteja bem informado em caso de mudanas nos parmetros de desempenho. Os projetos devem considerar os seguintes sistemas: Arquitetura Eltrica Ar-condicionado Telecomunicaes Gesto Manuteno Segurana
Sistemas Eltricos
Sistemas de Aterramento
Passagem de Cabos
Racks e Gabinetes
25
26
TIER II
TIER III
TIER IV
Commercial Building
Os elementos funcionais do cabeamento genrico so: a) Distribuidor de campus (CD); b) Backbone de campus; c) Distribuidor de edifcio (BD); d) Backbone de edifcio; e) Distribuidor de piso (FD); f) Cabeamento horizontal; g) Ponto de consolidao (CP); h) Cabo do ponto de consolidao (Cabo do CP); i) Tomada de telecomunicaes multiusurio (MUTO); j) Tomada de telecomunicaes (TO).
27
28
Industrial
Telecomunicaes
Rede de Acesso
Basicamente, as redes externas pticas so divididas em redes de longa distncia, que podem atingir centenas de milhares de quilmetros, redes metropolitanas, que abrangem desde vrias quadras de uma cidade at cidades inteiras, redes de acesso, mais prximas dos usurios finais e derivadas das extremidades das redes metropolitanas, e premises, redes de curta distncia predominantes em ambientes internos. Quando uma rede premise tem sua capacidade de transmisso completa, alm de ampliar a prpria rede premise, preciso investir nas redes de acesso, metropolitana e de longas distncias sucessivamente.Ao fazer este investimento preciso considerar o futuro e seus novos servios, ressaltando alguns pontos bsicos na escolha de qual tecnologia e produto utilizar na implantao desta nova rede.
As redes
Rede Troncal: composta por cabos que levam o sinal entre as centrais, onde ficam armazenados os equipamentos de transmisso e majoritariamente so aplicados em redes de dutos subterrneos. Rede Primria: composta por cabos que levam o sinal de uma central ao ponto de distribuio, sendo que estes cabos podem ser de aplicao em dutos subterrneos, instalao area espinados em cordoalha ou auto-sustentados, Rede Secundria: formada por cabos que levam o sinal dos pontos de distribuio s reas especficas de atendimento. Estes cabos geralmente so do tipo auto-sustentado com ncleo seco para facilidade de instalao.
Armrio de Distribuio Rede Primria
Central Telefnica
Rede Secundria
Pontos bsicos
Planejamento: Auxiliam na determinao do crescimento da rede em funo da demanda por servios. Provisionar: Detalhamento do projeto das partes componentes da rede, ou seja, da infraestrutura. Instalao: Implantao e teste das diversas partes componentes. Administrao: Compatibilidade para superviso e gerncia das redes dos servios de telecomunicaes. Manuteno: Facilidade nos servios de reparos para manter o funcionamento ininterrupto do sistema.
29
30
FTTx
Nomenclaturas
FTTH - Fiber-to-the-Home
Esta soluo pode ser definida como uma arquitetura de rede de transmisso ptica, onde a rede de distribuio adentra a residncia do assinante, que servido por uma fibra ptica exclusiva para este acesso. Geralmente, entre a rede de distribuio e a rede interna do assinante usado um mini-Dio ou um bloqueio ptico, para realizar a transio do sinal para o interior da residncia. Aps esta transio, o sinal disponibilizado atravs de uma extenso ou cordo ptico diretamente para o receptor do assinante.
Esta soluo pode ser definida como uma arquitetura de rede de transmisso ptica, onde a rede de distribuio termina na entrada de um edifcio, seja ele comercial ou residencial. A partir deste ponto terminal, o acesso interno aos usurios realizado geralmente atravs de uma rede metlica de cabeamento estruturado.
FTTB - Fiber-to-the-Building
FTTA - Fiber-to-the-Apartment
Esta soluo pode ser definida como uma arquitetura de rede de transmisso ptica, onde a rede de distribuio adentra o edifcio - comercial ou residencial - chegando a uma sala de equipamentos. A partir desta sala, o sinal ptico pode sofrer uma diviso atravs do uso de splitters pticos, sendo encaminhado individualmente a cada apartamento ou escritrio. Outras alternativas de diviso interna podem ser implementadas, mas cada unidade ser sempre atendida por uma nica e exclusiva fibra ptica. Ou seja, nesta soluo o ponto terminal de acesso interno aos usurios levado para dentro do apartamento ou escritrio.
O mercado da construo civil vem investindo cada vez mais em condomnios residenciais horizontais de alto padro em todo o mundo. Esses empreendimentos trazem servios diferenciados, como segurana integrada, automao nas residncias e disponibilizao de uma infraestrutura adequada que suporta avanadas tecnologias, como o FTTH.
Composto basicamente por cabos pticos que levam o sinal da central aos centros de distribuio. Para aplicao PON, as fibras so do tipo monomodo.
De maneira a otimizar o aproveitamento das fibras pticas, redes PON geralmente se apresentam em topologia Estrela-Distribuda. Neste local so instalados pequenos armrios pticos de distribuio associados a splitters pticos. Neste ponto de distribuio so realizados a diviso, distribuio e gerenciamento do sinal ptico associados a esta rea.
Formada por cabos pticos, levam o sinal dos centros de distribuio s reas especficas de atendimento. Associadas a estes cabos so utilizadas caixas de emenda denominadas NAP/Network Access Point para a distribuio do sinal, realizando a transio da rede ptica feeder rede terminal denominada de rede drop.
Composta por cabos pticos auto-sustentados de baixa formao de nmero de fibra. A partir da caixa de emenda terminal - NAP, leva o sinal ptico at o assinante propriamente dito. Podem terminar em pequenos DIOs (Distribuidor Interno ptico - para transio do cabo para cordo ptico) ou em pequenos bloqueios pticos no interior da casa/prdio. Devido s grandes restries de espao e utilizao de dutos j existentes, geralmente so utilizadas fibras pticas de caractersticas especiais, para se evitar perda de sinal por curvaturas acentuadas (fibra ptica tipo Bend Insensitive - G.657.A/B).
Rede Interna
A partir do bloqueio ptico (FOB) ou distribuidor interno ptico (DIO), so utilizadas extenses pticas ou cordes pticos para realizar a transio do sinal ptico da fibra ao receptor interno do assinante. Pelas mesmas razes de restrio de espao e utilizao de dutos existentes internamente casa do assinante, as extenses e cordes pticos so confeccionados com fibra ptica especial tipo Bend Insensitive - G.657.A/B.
31
32
A Furukawa teve em 2008 seus produtos certificados pelo Cisco Developer Networking Program - o programa de mais alto nvel entre todos os programas globais da Cisco Systems, destinado aos fornecedores de tecnologias complementares e compatveis com seus equipamentos e sistemas. Desde ento os fabricantes passaram a atuar em colaborao para o desenvolvimento tecnolgico de solues completas para redes avanadas de comunicao. Esta parceria agrega alta performance e dimensionalidade aos projetos de redes corporativas e, particularmente, ao mercado brasileiro e latino-americano de Data Center.
Produtos
33
34
GigaLan Augmented
GigaLan Categoria 6
MultiLan Categoria 5e
Fisacesso Infraestrutura
35
36
Redes Internas
Cabos telefnicos multipares de condutores de cobre isolados em termoplsticos, com construo em materiais adequados ao uso em ambientes internos, com caractersticas de retardncia a chamas.
Cabos telefnicos multipares de condutores de cobre isolados em termoplsticos, protegidos contra as intempries externas, indicados preferencialmente para instalao subterrnea no interior de linhas de dutos ou sub-dutos, e em instalaes areas, espinados junto ao mensageiro. Recomendados para a infra-estrutura de redes externas, como redes de cabos tronco, redes primrias e redes secundrias.
Cabos telefnicos multipares de condutores de cobre isolados em termoplsticos, protegidos contra as intempries externas, dotados de elementos de sustentao que permitem a instalao diretamente nos postes da linha de distribuio da rede eltrica. So recomendados para a infra-estrutura de redes externas nas redes secundrias.
Cabos pticos
Redes Internas
Cabos pticos com construo em materiais adequados ao uso em ambientes internos, com caractersticas de retardncia a chamas. O rpido avano tecnolgico ocorrido nas telecomunicaes e a necessidade de maiores taxas de transmisso que permitam diversos servios, como multimdia, internet, teleconferncia e outros, fazem das fibras e cabos pticos o melhor meio de transmisso.
Famlia de cabos pticos projetados com caractersticas adequadas para a terminao de sistemas pticos, fazendo a ligao entre o anel ptico metropolitano externo e o equipamento ptico localizado no interior das edificaes. Cabos aplicveis tanto para projetos de redes FTTH como para redes MAN/LAN.
Famlia de cabos pticos indicados preferencialmente para instalao subterrnea no interior de linhas de dutos ou sub-dutos, e em instalaes areas, espinados junto ao mensageiro. Estes cabos so aplicados em redes de entroncamentos, redes de assinantes e redes especiais, sendo os cabos com capacidade superior a 72 fibras pticas preferencialmente aplicados em redes de assinantes.
Rede composta por cabos pticos dotados de elementos de sustentao que permitem a instalao diretamente nos postes e torres da linha de distribuio ou transmisso da rede eltrica. Esta famlia de cabos possui desde cabos muito leves, para ligao do cliente final em reas urbanas, at cabos extremamente robustos, para instalao de backbones pticos em Linhas de Transmisso em reas sujeitas a condies ambientais muito severas de neve e vento.
Linha de cabos pticos projetados para serem instalados diretamente enterrados, sem a necessidade da existncia de infra-estrutura de canalizaes. Estes cabos so construtivamente mais robustos, para suportar os esforos mecnicos de compresso inerentes ao processo de instalaes diretamente enterradas. So indicados para instalaes de backbones pticos em regies de difcil acesso ou de locais desprovidos de infra-estrutura de dutos, ou ainda em situaes onde o uso da tcnica do uso de plow (arado adaptado para instalao simultnea) fornece uma excelente relao custo-benefcio da soluo.
37
38
Produtos
Dados Tcnicos
CASSETE HDMPO
Caractersticas construtivas Altura Largura Profundidade Tipo de pintura Cor Tipo de conector traseiro Tipo de conector frontal Codificao 35260150 CASSETE HDMPO 24F MM (50.0) OM3 10 GIGABIT LC-UPC CASSETE HDMPO 24F SM LC-UPC CASSETE HDMPO 12F MM (50.0) OM3 10 GIGABIT SC-UPC CASSETE HDMPO 12F SM SC-UPC Tipo de polimento Tipo da fibra Quantidade de fibras Performance Tipo de fibra SM MM OM3 Quantidade de ciclos Certificaes Anatel LC-APC LC-PC SC-APC SC-PC 0583-08-0256 1344-06-0256 0483-02-0256 1365-06-0256
39
29,2 mm 129,6 mm 101,50 mm (atende padro LGX) Pintura epxi p de alta resistncia a riscos Preta MPO (macho) 12 fibras LC-Duplex SC Simplex UPC (Multimodo) APC (Monomodo) Multimodo OM3 (50,0/125 m) Monomodo G.652D LC - duplex SC - simplex Perda de Insero Tpica 0,65dB 0,45dB > 500 inseres 24 fibras 12 fibras Perda de Insero Mxima 1,00dB 0,80dB
35260186 35260329
35260165
40
41
42
43
44
Pr-Conectorizados
35200279
35200278
35200329
35260165
45
46
33900032
Cordes e Extenses
PC ou SPC, UPC e APC (somente para fibras monomodo) Monomodo (9/125) Monomodo NZD (9/125) Multimodo (50/125) Multimodo (62.5/125) G.652.B, G.652.D, G.657.A G.655 OM4, OM3, OM2 OM1
Classe de flamabilidade Perda de Insero Perda de Retorno Quantidade de ciclos Certificaes Anatel
COG (fornecimento padro), COR e COG LSZH Os valores de performance esto em conformidade com a Norma ABNT NBR 14433. As perdas podem ser otimizadas por tipo de conector e polimento sob consulta. > 500 (por conector) LC-APC LC-PC SC-APC SC-PC FC-APC FC-PC ST-PC MT-RJ E2000-APC 0583-08-0256 1344-06-0256 0483-02-0256 1365-06-0256 0485-02-0256 1366-06-0256 0484-02-0256 1364-06-0256 0482-02-0256
47
48
CORDO PTICO
Caractersticas construtivas Dimetro nominal Comprimento Embalagem Codificao Sistema de codificao alfa-numrico para cordes e extenses pticas (vide tabela pg. 79) (1) Outros comprimentos sob consulta. 2,0 mm (fornecimento padro) 3,0mm De 0,5m a 100,0m Caixa de papelo
EXTENSAO OPTICA CONECTORIZADA 02F D2.0 (PARA DIO A270) - polimento SPC
49
50
35085011
35085012
12,0m: 10 peas 15,0m: 06 peas 20,0m: 05 peas Lote mnimo e mltiplo Certificaes ETL 3 conexes (U/UTP) ETL 4 conexes (F/UTP) 3132754CRT-003 3132755CRT-003 1 caixa
51
52
Codificao 23370016 CABO ELET. GIGALAN AUGMENTED CAT.6A F/UTP VD LSZH IEC 60332-3 (305M) CABO ELET. GIGALAN AUGMENTED CAT.6A 23AWGX4P F/UTP CZ CMR 305M
Dimetro nominal Peso do cabo Classe de flamabilidade Quantidade de pares Temperatura de instalao Temperatura de armazenamento Temperatura de operao Performance Desequilbrio resistivo mximo Resistncia eltrica CC mxima do condutor de 20C Capacitncia mtua mxima em 1kHz Desequilbrio capacitivo par x terra 1kHz mximo Impedncia caracterstica nom. de 1MHz a 250MHz Atraso de propagao mximo Diferena entre o atraso de propagao entre os pares 1 a 500 MHz Mximo Prova de tenso eltrica entre condutores Prova de tenso condutor-blindagem NVP Resistncia de isolamento Embalagem Lance padro Certificaes ETL Listed ETL Verified ETL 4 conexes (F/UTP) Anatel
23370005
Freq. (MHz) 1 4 8 10 16 20 25 31,25 62,5 100 200 250 300 400 500
RL (dB) Tpico 91,4 80,2 78 73,8 72,6 71,8 72,8 69,4 60,8 61 56,2 53,8 51,9 49,6 48,6
PSAACRF (dB) Min 20 23 24,5 25 25 25 24,3 23,6 21,5 20,1 18 17,3 16,8 15,9 15,2 Tpico 35,4 37,2 42,3 36,9 40,5 39,9 38,2 39,5 31,3 31,2 30,2 26,2 29,5 26,5 21,8 Min 67 67 67 67 67 67 67 67 65,6 62,5 58 56,5 55,3 53,5 52 Tpico 90 90,8 92,8 92,4 91,9 85,3 86,5 86,2 85,6 86,6 83,6 83,9 81,8 79,7 76,7 Min 67 66,2 60,1 58,2 54,1 52,2 50,2 48,3 42,3 38,2 32,2 30,2 28,7 26,2 24,2 Tpico 88 87,3 87 87,1 84,7 79,3 77,8 76,9 72,3 68,9 60,5 56,9 52,8 46,8 38,6
53
54
Dimetro nominal Peso do cabo Classe de flamabilidade Quantidade de pares Temperatura de instalao Temperatura de armazenamento Temperatura de operao Performance Desequilbrio Resistivo Resistncia eltrica CC mxima do condutor de 20C Capacitncia mtua mxima em 1kHz Desequilbrio capacitivo par x terra 1kHz mximo Impedncia caracterstica nom. de 1MHz a 250MHz Atraso de propagao mximo Diferena entre o atraso de propagao entre os pares 1 a 500 Mhz Mximo Prova de tenso eltrica entre condutores NVP Resistncia de Isolamento Embalagem Lance padro(1) Certificaes ETL Listed ETl Verified ETL 3 conexes (u/uTP) Anatel
Freq. (MHz) 1 4 8 10 16 20 25 31,25 62,5 100 200 250 300 400 500
Atenuao (dB) Max 2,1 3,8 5,3 5,9 7,5 8,4 9,4 10,5 15 19,1 27,6 31,1 34,3 40,1 45,3
N E X T (dB) Tpico 1,7 3,2 4,7 5,4 6,6 7,5 8,5 9,4 13,6 17,3 25,1 28,4 31,3 36,6 41,4
PSNEXT (dB) Min 74,3 65,3 60,8 59,3 56,2 54,8 53,3 51,9 47,4 44,3 39,8 38,3 37,1 35,3 33,8
ACRF (dB) Tpico 102,9 90,5 86 81,6 79 75,6 80,2 77,7 71,4 65,8 62,6 62,8 57,5 58 53
PSACRF (dB) Min 72,3 63,3 58,8 57,3 54,2 52,8 51,3 49,9 45,4 42,3 37,8 36,3 35,1 33,3 31,8
RL (dB) Tpico 89,7 80,4 77,8 73,8 71,5 68,2 69 68 64,8 59,8 50,6 49,1 48,2 48,5 40,8
PSANEXT (dB) Min 67,8 55,8 49,7 47,8 43,7 41,8 39,8 37,9 31,9 27,8 21,8 19,8 18,3 15,8 13,8 Tpico 95,9 69 60,2 57,3 51,5 48,2 44,6 42,8 38,9 37,8 34,3 32,7 30,5 36 28,5 Min 64,8 52,8 46,7 44,8 40,7 38,8 36,8 34,9 28,8 24,8 18,8 16,8 15,3 12,8 10,8 Tpico 85,1 73,8 67,1 65,1 61,3 59,3 56,3 54 47 45,6 38,3 39,9 37,3 35,6 28,3
PSAACRF (dB) Min 20 23 24,5 25 25 25 24,3 23,6 21,5 20,1 18 17,3 16,8 15,9 15,2 Tpico 34,2 34,2 33,8 32,5 38,7 35,9 35,5 37,8 35,2 34,3 29,9 27,8 28,7 24,7 23,6 Min 67 67 67 67 67 67 67 67 65,6 62,5 58 56,5 55,3 53,5 52 Tpico 89,1 89,9 87,1 86,7 84,3 81,8 79,7 79,8 76,2 71,2 65,7 63,6 62,4 60,8 59,5 Min 67 66,2 60,1 58,2 54,1 52,2 50,2 48,3 42,3 38,2 32,2 30,2 28,7 26,2 24,2 Tpico 86,9 79,4 72,8 70,2 66,5 64,5 62,6 61 54,5 50 40,9 38,3 34,8 30,6 26,6
Patch Cord
Tipo de conector Tipo de cabo Tipo de condutor Classe de flamabilidade Quantidade de pares Material do contato eltrico Material do corpo do produto Padro de montagem Temperatura de instalao Temperatura de armazenamento Temperatura de operao Performance Resistncia eltrica CC mxima do condutor a 20C Capacitncia mtua mxima a 1kHz Impedncia caracterstica nominal de 1MHz a 250MHz Prova de tenso entre condutores e blindagem NVP Diferena no atraso de propagao entre os pares Embalagem Caixa de papelo Quantidade por caixa
35125901
35125902
35125903
35125904
Outras configuraes sob consulta. Utilize tambm o codificador alfanumrico disponvel no site, na pgina web do produto.
De 12,0 a 15,0m: 06 peas Acima de 15,0m: 05 peas Certificaes Anatel UL Listed ETL 3 conexes (F/UTP) 1271-07-0256, 1273-07-0256 E173971 3102620CRT-03
55
56
35123303
Tipo de conector Tipo de cabo Tipo de Condutor Classe de Flamabilidade Quantidade de pares Material do contato eltrico Material do corpo do produto Padro de montagem Temperatura de instalao Temperatura de armazenamento Temperatura de operao Performance Resistncia Eltrica CC Mxima do Condutor a 20C Capacitncia Mtua Mxima a 1kHz Impedncia Caracterstica Nominal de 1MHz a 250MHz Prova de Tenso entre condutores e blindagem NVP Diferena no atraso de propagao entre os pares Embalagem Caixa de papelo Quantidade por caixa
35123304
35123305
35123306
35123307
Outras configuraes sob consulta. Utilize tambm o codificador alfanumrico disponvel no site, na pgina web do produto.
De 12,0 a 15,0m: 06 peas Acima de 15,0m: 05 peas Certificaes Anatel Anatel (LSZH) UL Listed ETL 4 conexes (U/UTP) ETL 6 conexes (U/UTP) ETL Verified 1276-07-0256, 1278-07-0256 2520-09-0256;2521-09-0256 E173971 3073041CRT-003 3118430CRT-003 3126372CRT-002C
35129001
35129003
35129018
35129008
35129004
Outras configuraes sob consulta. Utilize tambm o codificador alfanumrico disponvel no site, na pgina web do produto.
57
58
35129010
35129012
35129015
35129006
35129009
Outras configuraes sob consulta. Utilize tambm o codificador alfanumrico disponvel no site, na pgina web do produto.
Conector
59
60
35060602
35060603
35060604
35060605
35060606
35060607
35060608
35060609
35060610
35060611
35030602
Dimetro do condutor Padro de montagem ndice de proteo Performance Quantidade de ciclos Resistncia de isolamento Resistncia de contato Resistncia DC Prova de tenso dieltrica Fora de contato Temperatura de armazenamento Embalagem Quantidade por caixa Certificaes uL Listed
62
Dimetro do condutor Padro de montagem ndice de proteo Performance Quantidade de ciclos Resistncia de isolamento Resistncia de contato Resistncia DC Prova de tenso dieltrica Fora de contato Temperatura de armazenamento Embalagem Quantidade por caixa Certificaes UL Listed
Codificao 23360001
63
64
23400045
23400021
23400067
23420000
65
66
23360002
23400068
Freq. (MHz)
Atenuao dB TIA/EIA Mx. 2,0 3,8 5,3 6,0 7,6 8,5 9,5 10,7 15,4 19,8 29,0 32,8 Tpico 1,5 3,2 4,6 5,2 6,7 7,5 8,5 9,5 13,8 17,8 26,1 29,3 32,5 35,3 38,0 42,8 45,0 47,0
NEXT dB TIA/EIA Min. 74,3 65,3 60,8 59,3 56,2 54,8 53,3 51,9 47,4 44,3 39,8 38,3 Tpico 94,0 86,2 81,9 80,9 76,7 74,5 73,6 71,5 70,2 66,9 62,4 60,1 57,5 55,8 53,0 52,0 50,0 48,0
PSNEXT dB TIA/EIA Min. 72,3 63,3 58,8 57,3 54,2 52,8 51,3 49,9 45,4 42,3 37,8 36,3 Tpico 88,3 80,0 75,2 74,1 70,9 69,1 67,7 65,4 62,7 61,4 56,5 53,2 51,6 49,5 47,6 48,5 47,5 46,1
ACR dB TIA/EIA Min. 72,3 61,5 55,4 53,3 48,7 46,3 43,8 41,2 32,0 24,5 10,8 5,5 Tpico 88,5 77,1 70,0 68,8 64,0 60,9 59,5 57,6 48,9 43,9 29,2 23,4 18,9 12,5 7,0 5,0 2,0 -2,0
PSACR dB TIA/EIA Min. 70,3 59,5 53,4 51,3 46,7 44,3 41,8 39,2 30,0 22,5 8,8 3,5 Tpico 86,9 76,8 70,7 69,0 64,3 61,7 59,3 55,9 49,1 43,6 30,3 25,0 19,6 13,9 9,8 5,4 3,3 0,0
ELFEXT dB TIA/EIA Min. 67,8 55,8 49,7 47,8 43,7 41,8 39,8 37,9 31,9 27,8 21,8 19,8 Tpico 89,8 78,3 71,8 69,5 65,5 64,2 62,2 59,9 53,3 49,2 42,2 39,7 36,8 32,7 29,8 25,3 23,3 19,6
PSELFEXT dB TIA/EIA Min. 64,8 52,8 46,7 44,8 40,7 38,8 36,8 34,9 25,9 24,8 18,8 16,8 Tpico 82,5 70,3 64,6 62,4 58,6 57,0 55,0 52,6 45,6 40,6 33,8 31,7 29,3 26,0 24,4 19,5 17,6 13,7
RL dB TIA/EIA Min. 20,0 23,0 24,5 25,0 25,0 25,0 24,3 23,6 21,5 20,1 18,0 17,3 Tpico 35,0 35,7 38,7 37,6 41,9 38,4 39,1 38,5 35,9 31,9 28,4 26,5 25,2 23,9 23,9 24,9 25,7 24,0
1 4 8 10 16 20 25 31,25 62,5 100 200 250 300 350 400 500 550 600
67
68
Patch Panel
Dimetro do condutor Performance Fora de reteno entre jack e plug Quantidade de ciclos Resistncia de isolamento Resistncia de contato Resistncia DC Prova de tenso dieltrica Fora de contato Embalagem
Dimetro do condutor Performance Fora de reteno entre jack e plug Quantidade de ciclos Resistncia de isolamento Resistncia de contato Resistncia DC Prova de tenso dieltrica Fora de contato Embalagem
69
70
Patch Cord
Tipo de conector Tipo de cabo Tipo de condutor Classe de flamabilidade Quantidade de pares Material do contato eltrico Material do corpo do produto Padro de montagem Temperatura de instalao Temperatura de armazenamento Temperatura de operao Performance
35105903
35105910
35105904
35105909
Vide tabela de performance para cabos CAT.5e - pg. 116 Embalagem Quantidade por caixa Caixa de papelo De 0,5 a 2,5m: De 3,0 a 4,0m: De 4,0 a 6,0m: De 6,0 a 12,0m: 40 peas 25 peas 15 peas 10 peas
Outras configuraes sob consulta. Utilize tambm o codificador alfanumrico disponvel no site, na pgina web do produto.
De 12,0 a 15,0m: 06 peas Acima de 15,0m: 05 peas Certificaes Anatel UL listed ETL 3 conexes (F/UTP) 1272-07-0256, 1275-07-0256 E173971 3102621CRT-003
35103604
35103605
35103607
35103612
35103614
Outras configuraes sob consulta. Utilize tambm o codificador alfanumrico disponvel no site, na pgina web do produto.
De 12,0 a 15,0m: 06 peas Acima de 15,0m: 05 peas Certificaes Anatel uL Listed ETl Verified ETL 4 conexes (u/uTP) 1277-07-0256, 1279-07-0256 E173971 3126372CRT-001c 3075278CRT-003
71
72
35109000
35109008
35109003
35109001
35109009
Outras configuraes sob consulta. Utilize tambm o codificador alfanumrico disponvel no site, na pgina web do produto.
35109002
Material da capa Classe de flamabilidade Quantidade de pares Material do contato eltrico Material do corpo do produto
35109013
35109016
35109007
35109006
Outras configuraes sob consulta. Utilize tambm o codificador alfanumrico disponvel no site, na pgina web do produto.
73
74
Conector
35060505
35060502
35060501
35060504
35060509
35060510
35060503
35060507
35060508
75
76
35030502
Dimetro do condutor Padro de montagem ndice de proteo Performance Quantidade de ciclos Resistncia de isolamento Resistncia de contato Resistncia DC Prova de tenso dieltrica Fora de contato Temperatura de armazenamento Embalagem Quantidade por caixa Certificaes uL Listed
Dimetro do condutor Padro de montagem ndice de proteo Performance Quantidade de ciclos Resistncia de isolamento Resistncia de contato Resistncia DC Prova de tenso dieltrica Fora de contato Temperatura de armazenamento Embalagem Quantidade por caixa Certificaes UL Listed
77
78
Dimetro nominal Peso do cabo Classe de flamabilidade Quantidade de pares Temperatura de instalao Temperatura de armazenamento Temperatura de operao Performance
Vide tabela de performance para cabos CAT.5e - pg. 116 Embalagem Quantidade por Bobina Dimensionais Certificaes ETL 3 conexes (F/UTP) UL Listed Anatel 3102621 E160837 0037-08-0256 Caixa de papelo FASTBOX 305 metros 430 x 430 x 250 mm (LAP)
23200080
23200005
23200138
79
80
23350010
O desenvolvimento de cabos para uso externo soluciona os problemas em relao ao ambiente onde sero instalados, porm, de fundamental importncia a instalao de sistemas de proteo eltrica contra descargas atmosfricas, surtos e transientes, compatvel com a categoria do cabo que est sendo instalado.
23200134
O desenvolvimento de cabos para uso externo soluciona os problemas em relao ao ambiente onde sero instalados, porm, de fundamental importncia a instalao de sistemas de proteo eltrica contra descargas atmosfricas, surtos e transientes, compatvel com a categoria do cabo que est sendo instalado.
233550025
81
82
5% 93,8 /km 56 pF/m 3,3pF/m 10015% 545ns/100m @ 10MHz 45ns/100m 68 % 10000 M .km F/uTP 1.000 VDC/3s 500 VDC/3s
ELFEXT dB TIA/EIA Min. 63,8 51,7 45,7 43,8 39,7 37,7 35,8 33,9 27,8 23,8 Tpico 84,8 74,2 68,1 66,5 61,4 59,7 56,8 53,3 47,9 43,3 40,0 37,0 35,0 31,0
u/uTP 2.500 VDC/3s PSELFEXT dB TIA/EIA Min. 60,8 48,7 42,7 40,8 36,7 34,7 32,8 30,9 24,8 20,8 Tpico 76,5 65,3 59,2 57,4 53,2 51,3 48,9 45,6 40,2 35,7 31,0 29,0 27,0 24,0 RL dB TIA/EIA Min. 20,0 23,1 24,5 25,0 25,0 25,0 24,3 23,6 21,5 20,1 Tpico 35,7 39,1 36,3 35,1 36,0 37,5 37,7 34,8 34,1 32,3 31,2 29,4 29,0 28,1
Patch Panel
83
84
Codificao 35030151
Dimetro do condutor Performance Fora de reteno entre jack e plug Quantidade de ciclos Resistncia de isolamento Resistncia de contato Resistncia DC Prova de tenso dieltrica Fora de contato Embalagem
85
86
35050697
Estrutura metlica: Preto (epxi) Blocos de conexo: Bege 110 IDC Ao / TermoPlstico alto impacto UL94V-0 Caixa de papelo Quantidade por caixa: 01 pea Lote mnimo e mltiplo: 01 caixa
35050644
35050173
35050191
35050374
35050373
87
88
35120167
35120277
35120243
Outras configuraes sob consulta. Utilize tambm o codificador alfanumrico disponvel no site, na pgina web do produto.
De 12,0 a 15,0m: 06 peas Acima de 15,0m: 05 peas Certificaes Anatel UL Listed ETL 4 conexes (U/UTP) 1276-07-0256 E173971 3073041CRT-003
35101649
Outras configuraes sob consulta. Utilize tambm o codificador alfanumrico disponvel no site, na pgina web do produto.
De 12,0 a 15,0m: 06 peas Acima de 15,0m: 05 peas Certificaes Anatel UL Listed ETL 4 conexes 1277-07-0256 (certificado do cabo flexvel de 4 pares CAT.5e) 0645-10-0256 (certificado do cabo flexvel de 2 pares CAT.5e) E173971 3075278CRT-003
89
90
Codificao 23000002 23000010 23000018 23000026 CABO ELET. FIS-LAN 24AWGX2P -100- CZ CABO ELET. FIS-LAN 24AWGX4P -100- CZ CABO ELET. FIS-LAN 24AWGX12P -100- CZ CABO ELET. FIS-LAN 24AWGX25P -100- CZ
91
92
Racks e Gabinetes
RACK ABERTO 19
Produtos relacionados Guia de Cabos VerTical Fechado 140mm face simples (pg. 95) Guia de Cabos Horizontal Aberto Perfurado (pg. 97), Guia de Cabos Horizontal Fechado (pg. 97) Guia de Cabos Superior (pg. 98) e Guia de Cabos Inferior (pg. 99) Caractersticas construtivas Altura Largura Profundidade (base) Cor Material do corpo do produto Embalagem 44U (2169,6 mm) 36U (1774 mm) 540 mm 300 mm Preto (epxi) Ao SAE1020 Caixa de papelo Quantidade por caixa Lote mnimo e mltiplo Codificao 35150048 35150034 RACK ABERTO 19IN x 36U PRETO RACK ABERTO 19IN x 44U - PRETO 01 pea 01 caixa
35600032
93
94
Organizador de Cabos
95
96
35050287
97
98
99
100
PAINEL DE FECHAMENTO
Caractersticas construtivas 4u 2u 1u Codificao 35150084 35150086 35150118 PAINEL DE FECHAMENTO 1U PAINEL DE FECHAMENTO 2U PAINEL DE FECHAMENTO 4U Cor Material do corpo do produto Embalagem Largura Profundidade Largura Profundidade Largura Profundidade Preto (epxi) Ao SAE1020 Caixa de papelo Quantidade por caixa Lote mnimo e mltiplo 01 pea 01 caixa 482 mm 12 mm 482 mm 12 mm 482 mm 12 mm
101
102
35600045
103
104
35050322
35050323
35050269
105
106
107
108
CAIXA APARENTE
Produtos relacionados Caractersticas construtivas Dupla (4x4) Altura Largura Profundidade Simples (4x2) Altura Largura Profundidade Cor Material do corpo do produto Embalagem Bege / Branco Termoplstico ABS de alto impacto Caixa de papelo Quantidade por caixa Lote mnimo e mltiplo Codificao 35060029 35060028 35060042 35060050 CAIXA APARENTE PARA ESPELHO (4X4) - BEGE CAIXA APARENTE PARA ESPELHO (4X2) - BEGE CAIXA APARENTE PARA ESPELHO (4X2) - BRANCA CAIXA APARENTE PARA ESPELHO (4X4) - BRANCA 06 peas (Caixa 4x2) 04 peas (Caixa 4x4) 01 caixa 114 mm 116,2 mm 48 mm 114 mm 69 mm 48 mm Espelho Plano (pg. 111) Espelho Modular (pg. 111)
109
110
TOMADA APARENTE
Produtos relacionados Opo para F/UTP e U/UTP Conector Fmea GigaLan Standard CAT.6 (pg. 61), Conector Fmea GigaLan Premium CAT.6 (pg. 60) Conector Fmea GigaLan Standard CAT.6 (pg. 61), Conector Fmea GigaLan Premium CAT.6 (pg. 60) Conector Fmea Blindado GigaLan CAT.6 (pg. 59) Conector Fmea Blindado MultiLan CAT.5e (pg. 74) Caractersticas construtivas Codificao 35050256 35050255 35050257 35050259 35050258 35050260 35050510 35050511 TOMADA 1P - BEGE TOMADA 1P - BRANCO TOMADA 1P - CINZA TOMADA 2P - BEGE TOMADA 2P - BRANCO TOMADA 2P - CINZA TOMADA 1P - BEGE SOLUO BLINDADA TOMADA 2P - BEGE SOLUO BLINDADA Quantidade de posies Cor Tipo do conector Material do corpo do produto Embalagem 2P 1P Altura Largura Profundidade Altura Largura Profundidade 1 e 2 posies Bege, Branco, Cinza RJ-45, SC, LC, F, Tampa Cega TermoPlstico Caixa de papelo Quantidade por caixa Lote mnimo e mltiplo 20 peas para 1P 15 peas para 2P 01 caixa 44,5 mm 65 mm 19 mm 75,5 mm 65 mm 19 mm
ESPELHO ANGuLAR
Produtos relacionados Conector Fmea GigaLan Standard CAT.6 (pg. 61), Conector Fmea GigaLan Premium CAT.6 (pg. 60) Conector Fmea GigaLan Standard CAT.6 (pg. 61), Conector Fmea GigaLan Premium CAT.6 (pg. 60) Conector Fmea GigaLan Augmented CAT.6A (pg. 52) Caractersticas construtivas 3x3 4x4 ESPELHO ANGULAR 8P BEGE (4X4) ESPELHO ANGULAR 8P BRANCO (4X4) ESPELHO ANGULAR 8P CINZA (4X4) ESPELHO ANGULAR 2P BRANCO (3X3) ESPELHO ANGULAR 2P BEGE (3X3) Cor Tipo de conector Quantidade de posies Material do corpo do produto Embalagem Altura Largura Codificao 35050150 35050151 35050152 35050489 35050488 Altura Largura RJ-45 Tampa cega 2 8 Termoplstico resistente UL 94 V-0 Caixa de papelo Quantidade por caixa Lote mnimo e mltiplo 20 peas para 2P 10 peas para 8P 01 caixa 75 mm 75 mm 114,5mm 116,8 mm
ESPELHO PLANO
Produtos relacionados Caixa Aparente (pg. 109) cone de Identificao (pg. 113) Conector Fmea GigaLan Standard CAT.6 (pg. 61) e Conector Fmea GigaLan Premium CAT.6 (pg. 60) Conector Fmea MultiLan Standard CAT.5e (pg. 76) e Conector Fmea MultiLan Premium CAT.5e (pg. 75) Codificao 35050046 35050093 35050045 35050039 35050053 35050037 35050249 35050090 35050248 ESPELHO PLANO 6P BEGE (4X4) ESPELHO PLANO 6P BRANCO (4X4) ESPELHO PLANO 6P CINZA (4X4) ESPELHO PLANO 2P BEGE (4X2) ESPELHO PLANO 2P BRANCO (4X2) ESPELHO PLANO 2P CINZA (4X2) ESPELHO PLANO 4P BEGE (4X2) ESPELHO PLANO 4P BRANCO (4X2) ESPELHO PLANO 4P CINZA Simples (4x2) Caractersticas construtivas Duplo (4x4) Altura Largura Profundidade Altura Largura Profundidade Cor Tipo de conector Bege, Branco, Cinza RJ-45, SC, LC, F, Tampa cega 114,3 mm 114,3 mm 10 mm 114,3 mm 69,8 mm 10 mm
Quantidade de posies (4x4) 6 Quantidade de posies (4x2) 2 e 4 Material do corpo do produto Embalagem Termoplstico resistente UL 94 V-0 Caixa de papelo Quantidade por caixa Lote mnimo e mltiplo 25 peas (2 e 4 posies) 15 peas (6 posies 01 caixa
ESPELHO MODuLAR
Produtos relacionados Caractersticas construtivas Dimenso Cor Codificao 35060031 35060032 35060033 35060034 ESPELHO PLANO MODULAR (4X2) BEGE ESPELHO PLANO MODULAR (4X2) BRANCO ESPELHO PLANO MODULAR (4X4) BEGE ESPELHO PLANO MODULAR (4X4) BRANCO 4x4 (Duplo) 4x2 (Simples) Bege Branco Quantidade de posies (4x4) 06 mdulos Quantidade de posies (4x2) 03 mdulos Material do corpo do produto Embalagem Termoplstico resistente UL 94 V-0 Caixa de papelo Quantidade por caixa Lote mnimo e mltiplo 25 peas (4x2) 15 peas (4x4) 01 caixa 116x114x9,5 mm (LAP) 70x114x9,5 mm (LAP) Caixa Aparente (pg. 109) Mdulo para Espelho (pg. 112)
111
112
Adaptadores e Suportes
CONjuNTO ADAPTADOR
Produtos relacionados Patch Panel Descarregado 24P com cones (pg. 106) Espelho Plano (pg. 111) Cor Bege Branco Cinza Quantidade de posio Embalagem Codificao 35050344 35050379 35050376 35050663 35050662 35050664 35050250 CONJ. ADAPTADOR F BEGE (5 PCS) CONJ. ADAPTADOR F BRANCO (5 PCS) CONJ. ADAPTADOR F CINZA (5 PCS) DIVISOR DE VOZ DIVISOR MODULAR P/ CABO 4 PARES DIVISOR 10BASE-T ADAPTADOR DE FACEPLATE EUROPEU 45X22.5MM - BRANCO TAMPA CEGA - BEGE (10 PCS) TAMPA CEGA - BRANCA (10 PCS) TAMPA CEGA - CINZA (10 PCS) TAMPA CEGA - PRETA (10 PCS) Quantidade de posio Embalagem Tampa Cega Cor Conjunto Adaptador para Espelho Plano Cor Quantidade de posio Tipo de conector Embalagem Embalagem Adaptador Y (Rj-45) Cor Quantidade de posies Padro de montagem 01 posio Caixa de papelo Quantidade por caixa Lote mnimo e mltiplo Branca 01 para 02 posies Voz Modular 10BaseT Caixa de papelo Quantidade por caixa Lote mnimo e mltiplo Branco 01 posio RJ-45 Caixa de papelo Quantidade por caixa Lote mnimo e mltiplo Bege Cinza Branco Preto 01 posio Caixa de papelo Quantidade por caixa Lote mnimo e mltiplo Material do corpo do produto Termoplstico / Metlico 50 peas 01 caixa 25 peas 01 caixa 25 peas 01 caixa 25 peas 01 caixa
CONE DE IDENTIFICAO
Produtos relacionados Patch Panel Descarregado 24P com cones (pg. 106) Espelho Plano (pg. 111) e Espelho Angular (pg. 110) Tomada Aparente (pg. 110) Caractersticas construtivas Embalagem Material do corpo do produto Saco plstico Quantidade por caixa Lote mnimo e mltiplo Codificao 35050334 35050331 35050330 35050329 35050375 35050338 35050337 35050336 35050335 CONE DE IDENTIFICAO S5 - AMARELO CONE DE IDENTIFICAO S5 - AZUL CONE DE IDENTIFICAO S5 - BRANCO CONE DE IDENTIFICAO S5 - CINZA CONE DE IDENTIFICAO S5 - LARANJA CONE DE IDENTIFICAO S5 - MARROM CONE DE IDENTIFICAO S5 - VERDE CONE DE IDENTIFICAO S5 - VERMELHO CONE DE IDENTIFICAO S5 - VIOLETA 50 peas 01 caixa Termoplstico resistente UL 94 V-0
113
114
Ferramentas
Codificao 35060301 35060302 FERRAMENTA DE CRIMPAGEM RAPIDA PREMIUM MODULO DE CRIMPAGEM RAPIDA PREMIUM
A A B C B Codificao ALICATE DE CRIMPAGEM RJ-45 FERRAMENTA DE CONEXO 110 IDC FERRAMENTA DE TERMINAO 110 IDC LMINA PARA FERRAMENTA DE INSERO (110TYPE) 35050324 35050332 35050027 C 35300001
Equipamentos
MASTER
Produtos relacionados Software de Gerenciamento Patchview (pg. 119) Aplicaes Opcionais (pg. 119) Expander (pg. 116) Scanner (pg. 116) Mini-Scanner (pg. 117) Caractersticas construtivas Altura Codificao 35710006 PATCHVIEW - MASTER Largura Profundidade Cor Material do corpo do produto Quantidade de posies 44,4mm / 1,75 (1U) 482,6mm / 19 159,3mm / 6,27 Azul Ao SAE 01 Porta RJ-45 FTP (padro Ethernet) 01 Porta DB-9 macho (RS-232) 04 Portas RJ-45 FTP (RS-485) Alimentao Conexes Embalagem 100~240 VAC Automtico Monitora at 4 Scanners ou Expanders Caixa de papelo Quantidade por caixa 01 pea
MASTER EXPANDER
Produtos relacionados Software de Gerenciamento Patchview (pg. 119) Aplicaes Opcionais (pg. 119) Expander (pg. 116) Scanner (pg. 116) Mini-Scanner (pg. 117) Caractersticas construtivas Altura Codificao 35710012 PATCHVIEW - MASTER EXPANDER Largura Profundidade Cor Material do corpo do produto Quantidade de posies 44,4mm / 1,75 (1U) 482,6mm / 19 159,3mm / 6,27 Azul Ao SAE 01 Porta RJ-45 FTP (padro Ethernet) 01 Porta DB-9 macho (RS-232) 08 Portas RJ-45 FTP (RS-485) Alimentao Conexo Embalagem 100~240 VAC Automtico Monitora at 8 Scanners ou Expanders Caixa de papelo Quantidade por caixa 01 pea
115
116
EXPANDER
Produtos relacionados Master (pg. 115) ou Master Expander (pg. 115) Scanner (pg. 116) Mini-Scanner (pg. 117) Caractersticas construtivas Altura Largura Profundidade Codificao 35710016 PATCHVIEW - EXPANDER Cor Material do corpo do produto Quantidade de posies 44,4mm / 1,75 (1U) 482,6mm / 19 159,3mm / 6,27 Azul Ao SAE 08 Portas RJ-45 FTP (RS-485) para down link 01 Porta DB-9 macho (RS-232) 01 Portas RJ-45 FTP (RS-485) para uplink Alimentao Conexo Embalagem 100~240 VAC Automtico Controla diretamente at 8 Scanners ou outros Expanders. Caixa de papelo Quantidade por caixa 01 pea
SCANNER
Produtos relacionados Master (pg. 115) ou Master Expander (pg. 115) Expander (pg. 116) Patch Panel Gerencivel Modular (pg. 120) DIO Gerencivel LC DUPLEX 48F 24P 1U (pg. 122) e DIO Gerencivel LC DUPLEX/MPO 48F 24P 1U (pg. 122) Cabo Round Flat (pg. 118) Control PAD (pg. 118) Codificao 35710007 PATCHVIEW - SCANNER Caractersticas construtivas Altura Largura Profundidade Cor Material do corpo do produto Quantidade de posies 44,4mm / 1,75 (1U) 482,6mm / 19 191,7mm / 7,547 Azul Ao SAE 01 Porta RJ-45 para Control Pad 01 Portas RJ-45 FTP (RS-485) 01 Porta DB-9 macho (RS-232) 12 conectores traseiro com 26 pinos para cabo de conexo Round Flat Alimentao Conexo Embalagem 100~240 VAC Automtico Monitora at 24 Patch Panels / DIOs Gerenciveis de 24 portas. Caixa de papelo Quantidade por caixa 01 pea
MINI-SCANNER
Produtos relacionados Master (pg. 115) ou Master Expander (pg. 115) Expander (pg. 116) Cabo Round Flat (pg. 118) Patch Panel Gerencivel Modular (pg. 120) DIO Gerencivel LC DUPLEX 48F 24P 1U (pg. 122) e DIO Gerencivel LC DUPLEX/MPO 48F 24P 1U (pg. 122) Caractersticas construtivas Altura Largura Profundidade Cor Material do corpo do produto Quantidade de posies 44,4mm / 1,75 (1U) 482,6mm / 19 191,7mm / 7,547 Azul Ao SAE 01 Porta RJ-45 para Control Pad 01 Portas RJ-45 FTP (RS-485) 01 Porta DB-9 macho (RS-232) 06 conectores traseiro com 26 pinos para cabo de conexo Round Flat Alimentao Embalagem 100~240 VAC Automtico Monitora at 12 Patch Panels / DIOs Gerenciveis de 24 portas Caixa de papelo Quantidade por caixa Codificao 35710014 PATCHVIEW - MINI-SCANNER 01 pea
117
118
CONTROLADOR DE SEGuRANA
Produtos relacionados Master Expander (pg. 115) Expander (pg. 116) Caractersticas construtivas Altura Largura Profundidade Cor Codificao 35710176 CONTROLADOR DE SEGURANA Material do corpo do produto Quantidade de posies 44,4mm / 1,75 (1U) 482,6mm / 19 159,3mm / 6,27 Azul Ao SAE 01 Porta RJ-45 FTP (RS-485) 01 Porta DB9 macho (RS-232) 16 Portas I/O 08 sadas para Indicador para Rack 08 sadas para controle de cargas externas Alimentao Monitora at 8 RACKs Embalagem Caixa de papelo Quantidade por caixa 01 pea 100~240 VAC Automtico
CONTROL PAD
Produtos relacionados Scanner (pg. 116) Mini-Scanner (pg. 117) Caractersticas construtivas Cor Material do corpo do produto Quantidade de posies Codificao 35710008 PATCHVIEW - CONTROL PAD Embalagem Bege Termoplstico 01 Porta RJ-45 FTP (RS-485) Caixa de papelo Quantidade por caixa 01 pea
Suporta at 2 Patch Panel/DIO gerenciveis com 24 portas cada ou 1 Patch Panel com 48 portas. Embalagem Codificao 35710018 35710005 35710019 35710020 35710021 PATCHVIEW - CABO ROUND FLAT - TIPO B -1.5M PATCHVIEW - CABO ROUND FLAT - TIPO B - 2.5M PATCHVIEW - CABO ROUND FLAT - TIPO B -4.0M PATCHVIEW - CABO ROUND FLAT - TIPO B - 6.0M PATCHVIEW - CABO ROUND FLAT - TIPO B - 12.0M Caixa de papelo
Softwares
APLICAES OPCIONAIS
Funcionalidades Dashboard 360 Site Pro Anlise em tempo real, com medidores grficos de fcil visualizao. Gerao de relatrios grficos O SitePRO permite a integrao do PatchView com computadores de mo, os PDAs ou PALMTOPs Interao em tempo real na palma da mo, utilizando tecnologia de comunicao sem fio Suporte a envio e recebimento de mensagens on-line. Permite execuo e programao de ordens de servio eletrnicas Lote mnimo Codificao Licena para 1 ponto (DashBoard) ou 01 usurio (Site Pro) Codificao sob consulta
119
120
Patch Panel
121
122
Distribuidor ptico
35710211
35710212
35710193
35710194
123
124
35710187
35710188
35710002
35710031
125
126
Racks e Gabinetes
ARMRIO ORBITAL
Aplicao Armrio pr-montado e pr-terminado em fbrica, utilizado como ponto de distribuio local de fibras pticas em Redes FTTx. Caractersticas construtivas Altura Largura Profundidade Codificao 36100140 GABINETE OFS MODELO ORBITAL COM LC/APC ENTRADA 24 FIBRAS LOOSE E SADA 2X144 FIBRAS LOOSE GABINETE OFS MODELO ORBITAL COM LC/APC ENTRADA 48 FIBRAS LOOSE E SADA 2X144 FIBRAS LOOSE Material do corpo do produto Cor Quantidade de posies Tipo de fibra Tipo de conector Tipo de polimento Tipo de cabo (rabicho) ndice de proteo 920 mm 610 mm 460 mm Alumnio Bege(Epxi) 288 portas para Acesso e 48 portas para interconexo Monomodo (SM) LC, SC PC (SPC/UPC) / APC Cabos pticos de construo loose ou ribbon IEC IP-56 (equivalente a NEMA 4)
36100021
ARMRIO TRIBOX
Aplicao utilizado como ponto de distribuio local ou distribuio interna de fibras pticas em Redes FTTx, Redes HFC (Hbrido Fibra-Coaxial) ou redes de cabeamento estruturado. Caractersticas construtivas Altura Largura Profundidade Material do corpo do produto Cor Quantidade de posies Tipo de conector ndice de proteo 330 mm 600 mm 300 mm Ao Cinza (Epxi) 144 posies para adaptadores pticos tipo SC ou LC 12 slots para acomodao de splitters modulares ou painis LGX LC, SC IEC IP-54 (equivalente a NEMA 3R, 12 & 13) NEMA 3R, 12 & 13
Codificao 35260054 35260053 35260052 35250019 35260056 35260055 ARMRIO PTICO TRIBOX SUPORTE PARA BANDEJA DE EMENDA ARMRIO TRIBOX BANDEJA DE EMENDA PARA ARMRIO TRIBOX CONJUNTO DE 12 ADAPTADORES PTICOS SC PARA ARMRIO TRIBOX KIT PARA INSTALAO DE CABOS ARMRIO TRIBOX PAINEL PARA ADAPTADORES PTICOS SC 18F PARA ARMRIO TRIBOX
127
128
DIO BT48
Caractersticas construtivas Altura Largura Profundidade Cor Quantidade de posies 44 mm (1U) 484 mm 290 mm Cinza claro RAL 7035 12 adaptadores pticos, utilizando rgua 12F 24 adaptadores pticos, utilizando rgua 24F 48 adaptadores pticos, utilizando rgua 48F Codificao 35261002 35265014 35265016 35265017 35265018 35265019 DIO BT48 48F - MODULO BASICO DIO BT48 12F SM SC-APC ABNT - COMPLETO DIO BT48 48F SM SC-APC ABNT - COMPLETO DIO BT48 12F SM SC-UPC ABNT - COMPLETO DIO BT48 48F SM SC-UPC ABNT - COMPLETO DIO BT48 24F SM SC-APC ABNT - COMPLETO Material do corpo do produto Tipo de conector Tipos de polimentos Tipo de cabos Configurao Ao SAE1020 SC PC (Physical Contact) APC (Angled Physical Contact) Cabos pticos com construo tipo "tight" Cabos pticos com construo tipo "loose" Abraadeiras plsticas Cartes de identificao de fibras Parafusos e porcas gaiolas Bandejas de emenda Protetores de emenda Anilhas para identificao de tubo loose Adaptadores pticos (de encaixe) Extenses pticas
129
130
ROSETA PTICA
Caractersticas construtivas Altura Largura Profundidade Cor Tipo de conector Tipo de polimentos Quantidade de posies Codificao 35250163 ROSETA OPTICA 2P 4X2 SOBREPOR - BEGE Material do corpo do produto Classe de flamabilidade 114,9mm 79,8mm 22,5mm Bege (Ral 1015) SC e LC-Duplex PC (SPC/UPC) / APC 2 posies para emendas pticas por fuso ou mecnicas. 2 posio para adaptador ptico SC simplex ou LC duplex. Plstico ABS UL 94 V0 - queima cessa em 10 segundos numa amostra vertical; queda de partcula permitida desde que no infladas.
Splitter
35500112
35500109
SPLITTER DESBALANCEADO
Caractersticas construtivas Tipo de splitter Comprimento Dimetro nominal Comprimento do pigtail Dimetro da fibra nua Tecnologia de fabricao Performance Tipo de splitter Perda de Insero Mxima (dB) Sensibilidade Polarizao Mxima (PDL) Banda ptica Passante Diretividade Perda de Retorno Certificao Anatel Codificao 35500123 35500127 35500141 35500142 35500143 35500144 35500145 35500146 35500138 35500139 35500140 SPLITTER OPTICO FBT 1X2 01/99 G.657A NC/NC 2M/2M SPLITTER OPTICO FBT 1X2 02/98 G.657A NC/NC 2M/2M SPLITTER OPTICO FBT 1X2 05/95 G.657A NC/NC 2M/2M SPLITTER OPTICO FBT 1X2 10/90 G.657A NC/NC 2M/2M SPLITTER OPTICO FBT 1X2 15/85 G.657A NC/NC 2M/2M SPLITTER OPTICO FBT 1X2 20/80 G.657A NC/NC 2M/2M SPLITTER OPTICO FBT 1X2 25/75 G.657A NC/NC 2M/2M SPLITTER OPTICO FBT 1X2 30/70 G.657A NC/NC 2M/2M SPLITTER OPTICO FBT 1X2 35/65 G.657A NC/NC 2M/2M SPLITTER OPTICO FBT 1X2 40/60 G.657A NC/NC 2M/2M SPLITTER OPTICO FBT 1X2 45/55 G.657A NC/NC 2M/2M 2101-07-0256 1/99 21,6 0,30 0,2 dB 1260~1360nm e 1480~1580nm >55 dB >55 dB 2/98 18,7 0,4 5/95 14,6 0,5 10/90 11,0 0,7 15/85 9,6 1,0 20/80 7,9 1,4 25/75 6,95 1,7 30/70 6,0 1,9 35/65 5,35 2,3 40/60 4,7 2,7 45/55 4,15 3,15 1/99 50 mm 3 mm 2m 0,25 mm FBT 2/98 5/95 10/90 15/85 20/80 25/75 30/70 35/65 40/60 45/55
SPLITTERS 2XN
Caractersticas construtivas Tipo de splitter Comprimento Dimetro nominal Largura Codificao 35500121 SPLITTER OPTICO FBT 2X2 50/50 G.657A NC/NC 2M/2M SPLITTER OPTICO PLC 2X4 G.657A NC/NC 2M/2M SPLITTER OPTICO PLC 2X8 G.657A NC/NC 2M/2M SPLITTER OPTICO PLC 2X16 G.657A NC/NC 2M/2M SPLITTER OPTICO PLC 2X32 G.657A NC/NC 2M/2M SPLITTER OPTICO PLC 2X64 G.657A NC/NC 2M/2M Altura Tecnologia de fabricao Comprimento do pigtail Dimetro da fibra nua Performance Tipo de splitter Perda de Insero Mxima (dB) uniformidade (dB) Sensibilidade Polarizao Mxima (dB) Banda ptica Passante Diretividade Certificao Anatel 2101-07-0256 2x2 4,0 0,6 0,20 2x4 7,3 0,8 0,20 2x8 10,8 1,3 0,25 2x16 14 1,5 0,30 2x32 17,7 2,1 0,4 2x64 21,3 2,5 0,5 2x2 50mm 3mm N/A N/A FBT 2 metros 0,25mm 2x4 45mm N/A 5mm 4mm PLC 2x8 45mm N/A 5mm 4mm PLC 2x16 55mm N/A 7mm 4mm PLC 2x32 55mm N/A 7mm 4mm PLC 2x64 55mm N/A 12mm 4mm PLC
35500115
35500114
131
132
SPLITTERS CONECTORIZADOS
Performance Tipo de splitter Perda de Insero Mxima uniformidade Sensibilidade Polarizao Mxima (PDL) Banda ptica Passante Diretividade Certificao Anatel Codificao 35500101 35500103 35500106 35500117 35500111 35500107 35500110 35500122 35500129 35500128 35500126 35500133 35500134 35500135 35500136 35500137 35500130 35500131 35500132 SPLITTER OPTICO FBT 1X2 50/50 G.657A SC-APC/SC-APC 0.6D0.9/0.6D0.9 SPLITTER OPTICO PLC 1X4 G.657A SC-APC/SC-APC 0.6D0.9/0.6D0.9 SPLITTER OPTICO PLC 1X8 G.657A SC-APC/SC-APC 0.6D0.9/0.6D0.9 SPLITTER OPTICO PLC 1X16 G.657A SC-APC/MPO-APC 0.5D0.9/0.5 SPLITTER OPTICO PLC 1X32 G.657A SC-APC/MPO-APC 0.5D0.9/0.5 SPLITTER OPTICO PLC 1X16 G.657A SC-APC/SC-APC 1.5D2/ 1.5D2 SPLITTER OPTICO PLC 1X32 G.657A SC-APC/SC-APC 1.5D2/ 1.5D2 SPLITTER OPTICO PLC 1X64 G.657A SC-APC/SC-APC 1.5D2/ 1.5D2 SPLITTER OPTICO FBT 1X2 01/99 G.657A SC-APC/SC-APC 0.6D0.9/0.6D0.9 SPLITTER OPTICO FBT 1X2 02/98 G.657A SC-APC/SC-APC 0.6D0.9/0.6D0.9 SPLITTER OPTICO FBT 1X2 05/95 G.657A SC-APC/SC-APC 0.6D0.9/0.6D0.9 SPLITTER OPTICO FBT 1X2 10/90 G.657A SC-APC/SC-APC 0.6D0.9/0.6D0.9 SPLITTER OPTICO FBT 1X2 15/85 G.657A SC-APC/SC-APC 0.6D0.9/0.6D0.9 SPLITTER OPTICO FBT 1X2 20/80 G.657A SC-APC/SC-APC 0.6D0.9/0.6D0.9 SPLITTER OPTICO FBT 1X2 25/75 G.657A SC-APC/SC-APC 0.6D0.9/0.6D0.9 SPLITTER OPTICO FBT 1X2 30/70 G.657A SC-APC/SC-APC 0.6D0.9/0.6D0.9 SPLITTER OPTICO FBT 1X2 35/65 G.657A SC-APC/SC-APC 0.6D0.9/0.6D0.9 SPLITTER OPTICO FBT 1X2 40/60 G.657A SC-APC/SC-APC 0.6D0.9/0.6D0.9 SPLITTER OPTICO FBT 1X2 45/55 G.657A SC-APC/SC-APC 0.6D0.9/0.6D0.9 2101-07-0256 1x2 3,7 dB 0,5 dB 0,2 dB 1x4 7,1 dB 0,6 dB 0,2 dB 1x8 10,5 dB 1,0 dB 0,25 dB 1x16 13,7 dB 1,3 dB 0,3 dB 1x32 17,1 dB 1,5 dB 0,4 dB
Equipamentos
35510021
Conector Cabo Porta de Gerenciamento Serial Nmero de Portas Interface Conector Cabo Portas do Carto EPON Porta uplink Nmero de portas Interface Conector Cabo Porta PON Nmero de portas Interface Modo de transmisso Conector Cabo Comprimento de onda de transmisso Comprimento de onda de recepo
100BASE-TC / 1000BASE-T Auto Negotiation Auto MDIX Flow control for Full duplex RJ-45 UTP categoria 5e ou superior 1 porta por Carto de OLT 1000BASE-PX20 de acordo com IEEE802.3ah Downstram At 970 Mbps Upstream At 950 Mbps SC/BiDi 1.3mSMF (SM9.51/125m) 1310 nm 1490 nm
133
134
Codificao 35510022
35510023
UNI2
RJ-45 UTP categoria 5e ou superior 1 Porta 10Km 1000BASE-PXU (EPON)De acordo com IEEE802.3ah ITU-T G.652
20Km Modo de transmisso Conector Cabo Comprimento de onda de transmisso Comprimento de onda de recepo
Downstream 970 Mbps Upstream 950 Mbps SC-SPC (BiDi) 1.3mSMF (SM9.51/125m) 1310 nm 1490 nm
Conector Cabo Porta de Gerenciamento #2 Nmero da Porta Interface Conector Portas do Carto EPON Porta uplink Nmero de Portas Interface
135
136
RJ-45
Downstream 1000 Mbps em modo contnuo Upstream 1000 Mbps em modo Burst SC-SPC 1.3mSMF (SM9.51/125m) 1260 a 1360 nm 1480 a 1500 nm 10Km 20Km 20Km 10Km 20Km -0,5a+5,5 dBm -0,5a+5,5 dBm -0,5a+5,5 dBm -3 dBm a -26 dBm -3 dBm a -26 dBm
Conector Cabo Comprimento da onda de Transmisso Comprimento da onde de Recepo Nvel de Potncia de Transmisso Variao
LAN2 RJ-45
UTP categoria 5e ou superior 1 porta 10KM 20KM 1000BASE-PX10 De acordo com IEEE802.3ah 1000BASE-PX20 De acordo com IEEE802.3ah
Downstream 1000 Mbps em modo contnuo Upstream 1000 Mbps em modo Burst SC-SPC 1.3mSMF (SM9.51/125m) 1260 a 1360 nm 1480 a 1500 nm -0,5a+5,5 dBm -0,5a+5,5 dBm -3 dBm a -26 dBm -3 dBm a -26 dBm ITU-T G.652
Comprimento da onda de Transmisso Comprimento da onda de Recepo Nvel de Potncia de Transmisso Variao 10Km 20Km 10Km 20Km
137
138
Cabo ptico
Aplicao
Performance Conforme ABNT NBR 14772 e ET 1030 Certificao Embalagem Anatel UL OFNR Bobina de madeira Lance padro 2100 m(1) E179420
(1) Tolerncia de +/- 5%. Outros comprimentos de lances sob consulta *Nomenclatura ABNT (pg. 167)
139
140
Aplicao
02 a 12 Fibras dieltricas Material termoplstico no propagante chama e resistente "UV". Material hidroexpansvel Fita de ao corrugado Fio dieltrico para abertura longitudinal do cabo Material termoplstico no-propagante chama e resistente a UV. COG Dimetro externo nominal (mm) 11,7 Massa lquida Nominal (kg/km) 150 180 13,8 186 192 Raio mnimo de Curvatura (mm) Aps instalao 10 x dimetro do cabo
FIBER-LAN-AR 12 FIBRAS
Performance Conforme ABNT NBR 14772 e ET 2063 Embalagem Bobina de madeira Lance padro (1) Tolerncia de +/- 5%. Outros comprimentos de lances sob consulta 2100 m(1)
Aplicao
Aps a instalao 80 90
FIS-OPTIC-DG
Performance Conforme ABNT NBR 14772 e ET 690 Embalagem Bobina de madeira Lance padro (1) Tolerncia de +/- 5%. Outros comprimentos de lances sob consulta 2100 m(1)
141
142
Aplicao
OM1
CFOT-UT 12 FIBRAS
Performance Conforme ABNT NBR 14772 e ET 330 Certificao Embalagem Anatel Bobina de madeira Lance padro 2100 m(1)
Performance Conforme ABNT NBR 14772 e ET 2040 Embalagem Bobina de madeira Lance padro (1) Tolerncia de +/- 5%. Outros comprimentos de lances sob consulta. *Nomenclatura ABNT (pg. 167) 2100 m(1)
143
144
Performance Conforme ABNT NBR 15110, ABNT NBR 15108 e ET 1468 Certificao Embalagem Anatel Bobina de madeira Lance padro 2100 m(1)
(1)Tolerncia de +/- 5%. Outros comprimentos de lances sob consulta *Nomenclatura ABNT (pg. 167)
Raio mnimo de curvatura (mm) Durante a instalao 20 x dimetro do cabo Aps a instalao 10 x dimetro do cabo
Capa Externa Elemento de Trao Revestimento Externo Tubo de Proteo
Cordes pticos
Elemento Central Dieltrico Fibras pticas Material de Preenchimento Fios de Bloqueio de gua Rip Cord
CFOT-X-MF 6 FIBRAS
CFOT-X-UB 36 FIBRAS
Performance Conforme ABNT NBR 14772 e ET 1174 Certificao Embalagem Anatel Bobina de madeira Lance padro 2100 m(1)
(1) Tolerncia de +/- 5%. Outros comprimentos de lances sob consulta. *Nomenclatura ABNT (pg. 167)
145
146
Aplicao
Aps a instalao 75
Capa Externa
Performance Conforme ABNT NBR 15596 e ET 1659 Certificao Embalagem Anatel Bobina de madeira Lance padro (1) Tolerncia de +/- 1%. Outros comprimentos de lances sob consulta *Nomenclatura ABNT (pg. 167) 500 m(1)
Aplicao
OM1
(1) Tolerncia de +/- 5%. Outros comprimentos de lances sob consulta *Nomenclatura ABNT (pg. 167)
147
148
Aplicao Caractersticas Construtivas Tipo de fibra ptica, com revestimento em acrilato Quantidade de fibras Elemento de trao e sustentao Cordo de rasgamento Capa externa Cor
(1) Tolerncia de +/- 5%. Outros comprimentos de lances sob consulta. *Nomenclatura ABNT (pg. 167)
Cabo ptico
Rede Interna
Aplicao
149
150
Aplicao
CFOI-X-MF 6 FIBRAS
CFOI-X-UB 36 FIBRAS
Performance Conforme ABNT NBR 14771 e ET 696 Certificao Embalagem Anatel Bobina de madeira Lance padro 2000 m(1)
(1) Tolerncia de +/- 5%. Outros comprimentos de lances sob consulta *Nomenclatura ABNT (pg. 167)
151
152
CORDO PTICO
Designao Descrio COA-MF/DP* Cordo ptico formado com fibra isolada tipo Tight, por elemento de trao dieltrico e por capa externa em material termoplstico retardante chama Ambiente de instalao interno: Interligao de rede interna Monomodo (9/125) G.652.B G.652.D G.657 (BLI) Multimodo (50/125) OM4 OM3 OM2 Multimodo (62.5/125) Quantidade de fibras 02 para duplex (COA-DP) Cor do revestimento externo ABNT Cor do revestimento interno Elemento de trao Capa externa Classe de flamabilidade Branco (monofibra) Vermelho e Branco (duplex) Fibras dieltricas Material termoplstico restardante chama COG (fornecimento padro) LSZH Tipo do cordo Dimetro nominal externo (mm) 1,8 Monofibra (simplex) 2,0 (fornecimento padro) 2,9 1,8x3,7 Duplex 2,0x4,1 (fornecimento padro) 2,9x5,9 Tipo do cordo Monofibra (simplex) Duplex Carga mxima durante instalao (N) 200 400 Raio mnimo de curvatura (mm) 50
Revestimento Externo
OM1
0,9
COA-X-MF
Performance Conforme ABNT NBR 14106 e ET 1246 Certificao Embalagem Anatel Bobina de madeira Lance padro 1000 m(1)
(1) Tolerncia de +/- 5%. Outros comprimentos de lances sob consulta. *Nomenclatura ABNT (pg. 167)
Cabo ptico
Caractersticas Construtivas
OM1
02 a 144 At 200 m Material no metlico Seco - Material hidroexpansvel Fibras sintticas de aramida
NR RC Massa lquida nominal (kg/km) Vo (m) Dimetro externo nominal (mm) Massa lquida nominal (kg/km)
Fora de Trao sem Acrscimo de Atenuao (N) Vo (m) 80 120 200 Carga Mxima de Operao 1,5 x Peso do cabo /km 2 x Peso do cabo /km 3 x Peso do cabo /km
Raio Mnimo de Curvatura (mm) Durante instalao Carga Mxima de Operao aps instalao
Mxima 0,2
Recomendao para acessrios Utilize somente acessrios pr-formados na ancoragem dos cabos. A Furukawa no recomenda outros tipos de acessrios para este fim. Para maiores informaes, favor contatar a Furukawa.
Capa Externa Elemento de Trao Dieltrico Material de preenchimento
Elemento Central Dieltrico Tubo de Proteo Fibras pticas Fios de Bloqueio de gua Rip Cord
CFOA-X-ASY-S 36 FIBRAS
Performance Conforme ABNT NBR 14160 e ET 953 Certificao Embalagem Anatel Bobina de madeira
Lance padro 4000 m(1) (1) Tolerncia de +/- 3%. Outros comprimentos de lances sob consulta. *Nomenclatura ABNT (pg. 167)
153
154
Caractersticas Construtivas
OM1
02 a 144 At 200 m Material no metlico Geleado Polietileno ou copolmero Fibras sintticas de aramida Polietileno ou copolmero na cor preta com ou sem retardncia chama (NR ou RC)
NR RC Massa nominal (kg/km) Dimetro externo nominal (mm) Vo (m) Massa nominal (kg/km)
Fora de Trao sem Acrscimo de Atenuao (N) Vo (m) 80 120 200 Carga Mxima de Operao 1,5 x Peso do cabo /km 2 x Peso do cabo /km 3 x Peso do cabo /km
Raio Mnimo de Curvatura (mm) Durante instalao 20 x Dimetro Externo do Cabo Aps instalao 10 x Dimetro Externo do Cabo
Mxima 0,2
Recomendao para acessrios Utilize somente acessrios pr-formados na ancoragem dos cabos. A Furukawa no recomenda outros tipos de acessrios para este fim. Para maiores informaes, favor contatar a Furukawa.
Capa Externa Elemento de Trao Dieltrico
Capa Interna Material de Preenchimento Elemento Central Dieltrico Tubo de Proteo Fibras pticas
CFOA-X-ASY-G 36 FIBRAS
Performance Conforme ABNT NBR 14160 e ET 953 Certificao Embalagem Anatel Bobina de madeira Lance padro 4000 m(1)
(1) Tolerncia de +/- 3%. Outros comprimentos de lances sob consulta *Nomenclatura ABNT (pg. 167)
Aplicao
Caractersticas Construtivas Tipo de fibra ptica, com revestimento em acrilato G.652.B G.652.D G.655 02 a 72 De 5 a 20kN Material no metlico Seco - Material hidroexpansvel Polietileno ou copolmero Fibras sintticas de aramida Polietileno ou copolmero na cor preta com ou sem retardncia chama (NR ou RC) ou resistncia ao trilhamento (RT)
Tipo Resistente ao Trilhamento Retardante chama Normal N de Fibras pticas 02 a 12 5kN 18 a 36 48 a 72 02 a 12 10kN 18 a 36 48 a 72 02 a 12 15kN 18 a 36 48 a 72 02 a 12 20kN 18 a 36 48 a 72 Quantidade de fibras por tubo 2 6 12 2 6 12 2 6 12 2 6 12 Dimetro Externo Nominal (mm) 13,2 13,6 14,8 13,2 13,6 14,8 14,4 14,6 15,6 14,6 15 16,4 Marcao RT RC NR Massa Lquida Nominal (kg/km) 116 120 146 124 130 158 138 145 171 149 160 187
* CMO Carga Mxima de Operao (carga mxima que o cabo submetido com vento e temperatura coincidente de 15C) Carga de Compresso (N) 1 x Peso do cabo/km (Mnimo 1000) Raio Mnimo de Curvatura (mm) Durante instalao 20 x Dimetro Externo do Cabo Aps instalao 10 x Dimetro Externo do Cabo
Recomendao para acessrios Utilize somente acessrios pr-formados na ancoragem dos cabos. A Furukawa no recomenda outros tipos de acessrios para este fim. Para maiores informaes, favor contatar a Furukawa.
Capa Externa Elemento de Trao Dieltrico Fios de Bloqueio de gua Capa Interna Material de Preenchimento Elemento Central Dieltrico Tubo de Proteo Fibras pticas Rip Cord
CFOA-X-LVY-S 36 FIBRAS
Performance Conforme ABNT NBR 15330 e ET 949 Certificao Embalagem Anatel Bobina de madeira 4000 m
Lance padro (1) Tolerncia de +/- 3%. Outros comprimentos de lances sob consulta. *Nomenclatura ABNT (pg. 167)
155
156
Elemento de Trao
CFOA-X-AS120-RA 12 FIBRAS
Performance Conforme ABNT NBR 14160 e ET 352 Certificao Embalagem Anatel Bobina de madeira Lance padro (1) Tolerncia de +/- 5%. Outros comprimentos de lances sob consulta. *Nomenclatura ABNT (pg. 167) 3000 m(1)
Aplicao
CFOA-MM-ASU-80/120
Performance Conforme ABNT NBR 14160 e ET 631 Certificao Embalagem Anatel Bobina de madeira Lance padro 2100 m(1)
(1) Tolerncia de +/- 5%. Outros comprimentos de lances sob consulta *Nomenclatura ABNT (pg. 167)
157
158
Caractersticas Construtivas
OM1
02 a 288 Material no metlico Material hidro expansvel Fibras dieltricas Polietileno ou copolmero na cor preta Quantidade de fibras por tubo 2 6 Dimetro externo nominal (mm) 9,6 10,2 10,8 10,4 13 12 14,6 16,2 17 19,6 Durante instalao 20 x Dimetro Externo do Cabo Massa lquida Nominal (kg/km) 65 75 85 95 125 155 195 195 260 Aps instalao 10 x Dimetro Externo do Cabo
CFOA-X-DD-S 36 FIBRAS
Performance Conforme ABNT NBR 14566 e ET 119 Certificao Embalagem Anatel Bobina de madeira Lance padro 4000 m(1)
(1) Tolerncia de +/- 3%. Outros comprimentos sob consulta *Nomenclatura ABNT (pg. 167)
Aplicao
OM1
02 a 288 Material no metlico Geleado Fibras dieltricas Polietileno ou copolmero na cor preta Quantidade de fibras por tubo 2 6 Dimetro externo nominal (mm) 9,6 10 10,9 11,4 13,2 12 14,8 16,4 17 19,6 Durante instalao 20 x Dimetro Externo do Cabo Massa lquida Nominal (kg/km) 75 85 95 105 140 180 225 240 320 Aps instalao 10 x Dimetro Externo do Cabo
Rip Cord
CFOA-X-DD-G 36 FIBRAS
Performance Conforme ABNT NBR 14566 e ET 119 Certificao Embalagem Anatel Bobina de madeira Lance padro 4000 m(1)
(1) Tolerncia de +/- 3%. Outros comprimentos sob consulta *Nomenclatura ABNT (pg. 167)
159
160
CABO PTICO DIELTRICO PARA DuTOS COM PROTEO CONTRA ROEDORES - PFV
Designao Descrio CFOA-DDR* Cabo ptico de fibras pticas agrupadas em unidades bsicas preenchidas com gelia (tubo loose) e ncleo podendo ser geleado ou seco com materiais hidroexpansveis resistente penetrao de umidade, sendo este conjunto protegido por capa interna, camada de fibra de vidro e capa externa em polietileno. Ambiente de instalao externo - Subterrneas em dutos sujeito ao de roedores Ambiente de instalao interno e externo - Subterrneas em dutos sujeito a ao de roedores (Para os cabo seco com capa em material LSZH). Caractersticas Construtivas Tipo de fibra ptica, com revestimento em acrilato Monomodo (9/125) Monomodo NZD (9/125) Multimodo (50/125) G.652.B G.652.D G.655 OM4 OM3 OM2 Multimodo (62.5/125) Quantidade de fibras Elemento Central Ncleo Capa Interna Elemento de Trao Proteo contra roedores Capa Externa 02 a 288 Material no metlico Geleado Seco - Material hidro-expansvel Polietileno ou copolmero Fibras dieltricas Camada de fibra de vidro Polietileno ou copolmero na cor preta Copolimero LSZH preto N de Fibras pticas 2 a 12 18 a 36 48 a 60 72 96 120 144 216 288 Carga mxima de Instalao (N) 1000 Carga de Compresso (N) 2 x peso do cabo/km (mnimo 2000N)
Capa Externa Proteo Contra Roedores (PFV) Capa Interna Tubo de Proteo Fibras pticas Elemento Central Dieltrico Material de Preenchimento
Aplicao
OM1
Dimetro externo nominal (mm) 13,6 14,2 15 15,6 17,6 19,2 21,4 19,4 22,5
Massa lquida Nominal cabo geleado 175 190 205 230 280 330 405 395 475 Durante instalao 20 x Dimetro Externo do Cabo
Massa lquida Nominal cabo seco LSZH 203 218 235 258 310 363 443 425 510 Aps instalao 10 x Dimetro Externo do Cabo
Capa Externa Proteo Contra Roedores (PFV) Capa Interna Tubo de Proteo Fibras pticas Elemento Central Dieltrico Material de Preenchimento Fios de Bloqueio de gua
(kg/km)
12
Rip Cord
Rip Cord
CFOA-X-DDR-G 36 FIBRAS
CFOA-X-DDR-S 36 FIBRAS
Performance Conforme ABNT NBR 14773 e ET 945 Certificao Embalagem Anatel Bobina de madeira Lance padro 4000 m(1)
(1) Tolerncia de +/- 3%. Outros comprimentos de lances sob consulta. *Nomenclatura ABNT (pg. 167)
Cabo ptico CABO PTICO PARA DuTOS COM PROTEO METLICA CONTRA ROEDORES
Designao Descrio CFOA-ARD* Cabo ptico com armadura formado de fibras pticas agrupadas em unidades bsicas preenchidas com gelia (tubo loose) e ncleo podendo ser geleado ou com material hidro-expansvel resistente penetrao de umidade, elementos de trao, sendo este conjunto protegido por fita de ao corrugado anti-roedor e capa externa em polietileno. Ambiente de instalao externo - Subterrneo em dutos sujeito ao de roedores Monomodo (9/125) Monomodo NZD (9/125) MultImodo (50/125) G.652.B G.652.D G.655 OM4 OM3 OM2 MultImodo (62.5/125) Quantidade de fibras Elemento Central Ncleo Elemento de Trao Proteo contra roedores Capa Externa N de Fibras pticas 2 a 12 18 a 36 48 a 72 96 120 144 216 288 Carga mxima de Instalao (N) 2 x Peso do cabo/km (Mnimo 2000N) Carga de Compresso (N) 1 x Peso do cabo/km (Mnimo 1000) (Mximo 2200)
Capa Externa Rip Cord Tubo de Proteo Fibras pticas Elemento Central Dieltrico Elemento de Trao Material de Preenchimento Fita de Bloqueio de gua Fita de Ao Corrugado
Aplicao
OM1
02 a 288 Material no metlico Geleado Seco - Material hidro-expansvel Fibras dieltricas Fita de ao corrugado Polietileno ou copolmero na cor preta Quantidade de fibras por tubo 2 6 Dimetro externo nominal (mm) 11,5 12 13,5 15 12 16,5 18,7 20,4 23,4 Durante instalao 20 x Dimetro Externo do Cabo Massa lquida nominal (kg/km) 130 140 175 215 260 315 420 540 Aps instalao 10 x Dimetro Externo do Cabo
Capa Externa Rip Cord Tubo de Proteo Fibras pticas Elemento Central Dieltrico Elemento de Trao Material de Preenchimento Fios de Bloqueio de gua Fita de Bloqueio de gua Fita de Ao Corrugado
CFOA-X-ARD-G 36 FIBRAS
CFOA-X-ARD-S 36 FIBRAS
Performance Conforme ABNT NBR 15108 e ET 966 Certificao Embalagem Anatel Bobina de madeira Lance padro 4000 m(1)
(1) Tolerncia de +/- 3%. Outros comprimentos de lances sob consulta. *Nomenclatura ABNT (pg. 167)
161
162
Aplicao
OM1
Massa lquida nominal (kg/km) 165 175 215 260 310 365 500 630 Aps instalao 10 x Dimetro Externo do Cabo
Rip Cord
CFOA-X-ARE-G 36 FIBRAS
Performance Conforme ABNT NBR 15110 e ET 2009 Embalagem Bobina de madeira Lance padro 4000 m (1)
(1) Tolerncia de +/- 3%. Outros comprimentos de lances sob consulta *Nomenclatura ABNT (pg. 167)
Aplicao
OM1
Massa lquida Nominal (kg/km) 92 102 115 130 170 210 255 Aps instalao 10 x Dimetro Externo do Cabo
Rip Cord
CFOA-X-DE-G 36 FIBRAS
Performance Conforme ABNT NBR 14103 e ET 1177 Certificao Embalagem Anatel Bobina de madeira Lance padro 4000 m(1)
(1) Tolerncia de +/- 3%. Outros comprimentos de lances sob consulta. *Nomenclatura ABNT (pg. 167)
163
164
CABO PTICO DIELTRICO DIRETAMENTE ENTERRADO COM PROTEO CONTRA ROEDORES - PFV
Designao Descrio CFOA-DER-G (PFV)* Cabo ptico de fibras pticas agrupadas em unidades bsicas preenchidas com gelia (tubo loose) e ncleo geleado resistente penetrao de umidade, sendo este conjunto protegido por capa interna, revestimento interno em poliamida, camada de fibra de vidro e capa externa em polietileno. Instalao externa - Diretamente enterradas sujeita ao de roedores, formigas e cupins (termitas). Monomodo (9/125) Monomodo NZD (9/125) Multimodo (50/125) G.652.B G.652.D G.655 OM4 OM3 OM2 Multimodo (62.5/125) Quantidade de fibras Elemento Central Ncleo Capa Interna Revestimento interno Proteo contra roedores Capa Externa N de Fibras pticas 2 a 12 18 a 36 48 a 60 72 96 120 144 Carga mxima de Instalao (N) 1000 Carga de Compresso (N) 1 x Peso do cabo/km (Mnimo 1000) (Mximo 2200) 12 02 a 144 Material no metlico Geleado Polietileno ou copolmero Poliamida (Nylon) Camada de fibra de vidro Polietileno ou copolmero na cor preta Quantidade de fibras por tubo 2 6 Dimetro externo nominal (mm) 18,5 18,5 18,8 19,5 21,9 23,1 25,9 Durante instalao 20 x Dimetro Externo do Cabo
Capa Externa Proteo Contra Roedores (PFV) Revestimento de Nylon Capa Interna Tubo de Proteo Elemento Central Dieltrico Fibras pticas Material de Preenchimento Rip Cord
Aplicao
OM1
Massa lquida nominal (kg/km) 379 383 390 395 417 460 502 Aps instalao 10 x Dimetro Externo do Cabo
Performance Conforme ABNT NBR 14774 e ET 858 Certificao Embalagem Anatel Bobina de madeira Lance padro 4000 m(1)
(1) Tolerncia de +/- 3%. Outros comprimentos de lances sob consulta. *Nomenclatura ABNT (pg. 167)
Cabo ptico CABO PTICO DIELTRICO DIRETAMENTE ENTERRADO COM PROTEO CONTRA ROEDORES - PPu
Designao Descrio CFOA-DER-G (PPU)* Cabo ptico de fibras pticas agrupadas em unidades bsicas preenchidas com gelia (tubo loose) e ncleo geleado resistente penetrao de umidade, sendo este conjunto protegido por capa interna, revestimento interno em poliamida, camada de elementos pultrudados e capa externa em polietileno. Instalao externa - Diretamente enterrada sujeita ao de roedores, formigas e cupins (termitas). Monomodo (9/125) Monomodo NZD (9/125) Multimodo (50/125) G.652.B G.652.D G.655 OM4 OM3 OM2 Multimodo (62.5/125) Quantidade de fibras Elemento Central Ncleo Capa Interna Revestimento interno Proteo antiroedores Elemento de trao Capa Externa N de Fibras pticas 2 a 12 18 a 36 48 a 60 72 96 120 144 Carga mxima de Instalao (N) 1000 Carga de Compresso (N) 1 x Peso do cabo/km (Mnimo 1000) (Mximo 2200) 12 02 a 144 Material no metlico Geleado Polietileno ou copolmero Poliamida (Nylon) Camada de Fibra Reforada Plstica (FRP) Elemento Pultrudado Fibras dieltricas Polietileno ou copolmero na cor preta Quantidade de fibras por tubo 2 6 Dimetro externo nominal (mm) 19,8 19,8 20,1 20,9 22,8 24,7 26,7 Durante instalao 20 x Dimetro Externo do Cabo
Capa Externa Enfaixamento Proteo Contra Roedores (PPU) Revestimento de Nylon Capa Interna Elemento Central Dieltrico Tubo de Proteo Material de Preenchimento Fibras pticas
Aplicao
OM1
Massa lquida nominal (kg/km) 406 410 412 419 459 506 552 Aps instalao 10 x Dimetro Externo do Cabo
Performance Conforme ABNT NBR 14774 e ET 858 Certificao Embalagem Anatel Bobina de madeira Lance padro 4000 m(1)
(1) Tolerncia de +/- 3%. Outros comprimentos de lances sob consulta. *Nomenclatura ABNT (pg. 167)
165
166
Aplicao
OM1
Massa lquida Nominal (kg/km) Cabo 84 100 108 122 158 195 245 Duto 200 215 230 230 290 310 340
Revestimento Externo (Nylon) Capa Externa Elemento de Trao Tubo de Proteo Elemento Central Dieltrico Material de Preenchimento
Rip Cord
CFOA-X-DPE-G 36 FIBRAS
Performance Conforme ABNT NBR 14103 e ET 713 Certificao Embalagem Anatel Bobina de madeira Lance padro At 72F - 4000 m, 96F - 2500 m e 144F - 2000 m
(1) Tolerncia de +/- 3%. Outros comprimentos de lances sob consulta. *Nomenclatura ABNT (pg. 167)
C F O A- X - ASY - W - Z- K
Tipos de Revestimento NR - Normal RC - Retardante Chama Nmero de Fibras pticas G - Ncleo Geleado, S - Ncleo Seco Vo Mximo - (80, 120 e 200m) AS - Auto Sustentado ASU - Auto Sustentado Tubo nico MM - Multimodo Tipos de Fibras: SM - Monomodo NZD - Disperso no zero Revestimento de Fibra Acrilato ptica Fibra Cabo
C FO A - X- LV-AS-Y-W-Z-K
Tipos de Revestimento RT - Resistente ao Trilhamento NR - Normal RC - Retardante Chama Nmero de Fibras pticas G - Ncleo Geleado, S - Ncleo Seco Carga Mxima de Operao (5, 10, 12,15, 20 e 25kN) AS - Auto Sustentado Longos Vos MM - Multimodo Tipos de Fibras: SM - Monomodo NZD - Disperso no zero Revestimento de Fibra Acrilato ptica Fibra Cabo
C F O A - X -Y-W-Z (K)
C F O T- X - Y -Z - W
Caractersticas Especias PFV - Proteo com Fibra de Vidro PPU - Proteo com Elemento Pultrudado Nmero de Fibras pticas G - Ncleo Geleado, S - Ncleo Seco Aplicao DD - Dieltrico para Instalaes em Dutos do Cabo: DE - Dieltrico para Instalaes Diretamente Enterradas DPE - Dieltrico e Protegido para Instalaes Diretamente Enterradas ARD - Protegido com Armadura em Fita de Ao Corrugado, para Instalaes em Dutos ARE - Protegido com Armadura em Fita de Ao Corrugado, para Instalaes Diretamente Enterradas DER - Dieltrico e Proteo contra Roedores para Instalaes Diretamente Enterradas DDR - Dieltrico e Proteo contra Roedores para Instalaes em Dutos MM - Multimodo Tipos de Fibras: SM - Monomodo NZD - Disperso no zero Revestimento de Fibra Acrilato ptica Fibra Cabo Fibra Cabo
Grau de Proteo do Cabo Frente Chama COG - Cabo ptico Geral COR - Cabo ptico Riser COP - Cabo ptico Plenum LSZH - Cabo ptico com Baixa Emisso de Fumaa Low Smoke and Zero Halogen
Nmero de Fibras pticas MF- Monobra Formao do Ncleo: EO- Elemento ptico UB- Unidade Bsica MM - Multimodo Tipos de Fibras: SM - Monomodo NZD - Disperso no zero Terminao ptica
C O A -X - Y- Z - W
Grau de Proteo do Cabo Frente Chama COG - Cabo ptico Geral COR - Cabo ptico Riser COP - Cabo ptico Plenum LSZH - Cabo ptico com Baixa Emisso de Fumaa Low Smoke and Zero Halogen Dimetro do Cordo ptico: 16 - 1,6mm 18 - 1,8mm 20 - 2,0mm 25 - 2,5mm 29 - 2,9mm Formao: MF - Cordo Monofibra (Simplex) DP - Cordo Duplo (Duplex Zip Cord) MM - Multimodo Tipos de Fibras: SM - Monomodo NZD - Disperso no zero Revestimento da Fibra Acrilato ptico Cordo
REDE INTERNA
C F O I - X -Y - Z - W
Grau de Proteo do Cabo Frente Chama COG - Cabo ptico Geral COR - Cabo ptico Riser COP - Cabo ptico Plenum LSZH - Cabo ptico com Baixa Emisso de Fumaa Low Smoke and Zero Halogen Nmero de Fibras pticas MF- Monobra Ncleo do Cabo: EO- Elemento ptico UB- Unidade Bsica MM - Multimodo Tipos de Fibras: SM - Monomodo NZD - Disperso no zero Interno ptica Fibra Cabo
CF O AC - X -Y - W - Z - K
Grau de Proteo do Cabo Frente Chama COG - Cabo ptico Geral COR - Cabo ptico Riser COP - Cabo ptico Plenum LSZH - Cabo ptico com Baixa Emisso de Fumaa Low Smoke and Zero Halogen Nmero de Fibras pticas MF- Monobra Ncleo do Cabo: AS - Areo Auto Sustentado ASU - Subterrneo em Duto MM - Multimodo Tipos de Fibras: SM - Monomodo NZD - Disperso no zero Acesso ao assinante Revestimento de fibra "acrilato". ptica Cabo Fibra EO- Elemento ptico UB- Unidade Bsica
167
168
Rede Interna
10 a 1200 Seco Fio de cobre eletroltico, macio e estanhado Polietileno de alta densidade Material polimrico retardante chama (PVC) Cinza CM
Nmero de pares 10 15 20 25 30 40 50 Dimetro externo nominal (mm) 7,1 8,1 9,0 10,3 10,6 11,7 12,5 13,8 16,1 22,6 28,5 32,9 40,1 48,1 54,2 8,5 9,0 10,2 10,8 11,7 13,0 14,5 17,6 19,1 26,4 32,6 37,0 45,1 54,0 61,6 9,1 10,1 11,6 12,6 13,6 15,1 16,6 19,6 22,1 31,1 36,6 41,6 50,1 Massa lquida nominal (kg/km) 67 88 105 132 145 183 216 305 380 748 892 1293 1980 2831 3755 87 114 137 163 190 242 293 408 520 1033 1333 1750 2832 4172 5483 91 124 165 198 232 297 368 543 702 1450 2084 2746 3997 250 500 1000 250 500 1000 250 500 1000 Comprimento nominal (m)
FAST-CIT 40
0,4
FAST-CIT 50
0,5
FAST-CIT 60
0,6
169
170
171
172
173
174
175
176
177
178
CARACTERSTICAS ELTRICAS
CTP-APL; CTP-APL-G; CTP-APL-AS; CTS-APL-G; CCE-APL (1); CCE-APL-G (1); Slido Dimetro do Condutor (mm) Resistncia Eltrica Mxima (W / km a 20C) Desequilibrio Resistivo (%) Capacitncia Mtua (nF/km) Mdia Mxima Mximo Individual 20 pares > 20 pares RMS Mxima Mximo Individual Mdia Mxima Mximo Individual RMS Mnima Mnimo Individual RMS Mnima Mnimo Individual Mnimo Individual Mnimo Individual Geleado Mdia nominal 1024 kHz Seco Geleado Seco CxC Tenso Aplicada (Vcc/3s) CxB Geleado Seco Geleado Seco 11,8 12,0 25,7 27,0 2800 2500 10000 12,4 n/a 26,0 n/a 2400 n/a 10000 n/a 7,9 8,3 19,8 20,4 4000 3000 10000 8,0 n/a 20,0 n/a 3000 n/a 10000 n/a Foam Skin 0,40 147,2 2,0 5,0 Slido Foam Skin 0,50 94,0 1,5 5,0 51 5 51 3 45,3 181 574 2625 68 58 52 35 53 40 5,4 6,0 15,0 16,0 5000 3600 10000 n/a 9,3 n/a 23,5 n/a 3000 n/a 10000 31,4 13,4 n/a 11,6 n/a 30,1 n/a 1500 n/a 2800 23,9 8,7 Slido 0,65 55,8 1,5 4,0 CTP-APL-SN Slido 0,50 97,8 3,0 7,0 0,40 153,0 FAST -CIT Slido 0,50 97,8 3,0 7,0 70 0,60 67,9
Cabo
Mdia
150 kHz
179
180
8,5 MHz CTP-APL-xDSL; CTP-APL-G-xDSL; CTS-APL-G-xDSL; FAST-CIT-xDSL (1) Ncleo Seco ou Geleado e dimetro de condutor de 0,40 mm
Impedncia Caracterstica (W) Atenuao de Transmisso a 20C (dB/100m) 0,9 1,2 1,3 130 20 1,9 2,4 4,1 4,8 Perda de Retorno (dB) 36 32 30 28 26 24 18
40 MHz CTP-APL-xDSL; CTP-APL-G-xDSL; CTS-APL-G-xDSL; FAST-CIT-xDSL (1) Ncleo Seco ou Geleado e dimetro de condutor de 0,50 mm
Impedncia Caracterstica (W) Atenuao de Transmisso a 20C (dB/100m) 0,8 1,0 1,3 1,9 100 15 2,6 4,7 5,5 8,7 10,9 12,4 Perda de Retorno (dB) 39 36 34 32 31 29 21 18 15 14
Caractersticas de Transmisso
Frequncia (MHz) 0,15 0,30 0,50 1,1 2 6,3 8,5 PSNEXT (dB) 67 63 59 50 45 39 34 PSELFEXT (dB/100m) 66 63 58 52 47 38 34 Frequncia (MHz) 0,15 0,30 0,50 1,1 2 6,3 8,5 20 31,25 40 PSNEXT (dB) 73 69 66 58 53 46 42 39 34 32 PSELFEXT (dB/100m) 71 68 64 57 51 44 40 35 30 23
FORMAES MLTIPLAS
Nmero do Grupo ou Super-Grupo 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Cor de Amarrao do Grupo ou Super-Grupo B-Az B-L B-V B-M B-C E-Az E-L E-V E-M E-C P-Az P-L P-V P-M P-C Am-Az Am-L Am-V Am-M Am-C Vt-Az Vt-L Vt-V Vt-M Sequncia dos Pares nos Grupos 1 a 25 26 a 50 51 a 75 76 a 100 101 a 125 126 a 150 151 a 175 176 a 200 201 a 225 226 a 250 251 a 275 276 a 300 301 a 325 326 a 350 351 a 375 376 a 400 401 a 425 426 a 450 451 a 475 476 a 500 501 a 525 526 a 550 551 a 575 576 a 600 Sequncia dos Pares nos Super-Grupos 1 a 100 101 a 200 201 a 300 301 a 400 401 a 500 501 a 600 601 a 700 701 a 800 801 a 900 901 a 1000 1001 a 1100 1101 a 1200 1201 a 1300 1301 a 1400 1401 a 1500 1501 a 1600 1601 a 1700 1701 a 1800 1801 a 1900 1901 a 2000 2001 a 2100 2101 a 2200 2201 a 2300 2301 a 2400
Abreviao das cores utilizadas: B = Branco, Az = Azul, L = Laranja,V = Verde, M = Marrom, C = Cinza, E = Encarnado, P = Preto, Am = Amarelo,Vt = Violeta
181
182
Normas
INTRODUO
vrias organizaes desenvolvem padres para assegurar que todos os protocolos, eletrnica de sinais, tipo de mdia e a infra-estrutura de projeto sejam compatveis. Hoje essencial que os profissionais de telecomunicaes familiarizem-se com os padres existentes e em desenvolvimento para atender s necessidades atuais e requisitos futuros. Hoje existem normas americanas, europias, brasileiras, japonesas que estabelecem os requisitos mnimos para o funcionamento e a interoperabilidade das redes estruturadas. importante conhecer os principais aspectos das normas ansI/tIa/eIa 568 que trata do cabeamento estruturado, IsO/Iec 11801, aBnt/nBr 14565 para os produtos e desempenho dos sistemas montados e as normas eIa/tIa 942, eIa/tIa 569-B,eIa/tIa 570B, sobre infra-estrutura para suportar o cabeamento. Outras normas so a ansI/tIa/eIa 606, sobre administrao e identificao e a ansI/tIa/eIa 607 sobre aterramento.
ISO/IEC
a IsO (International Organization for standardization) e a Iec (International electrotechnical comission) formam o sistema de normatizao internacional. Para a rea de tecnologia de informao, IsO e Iec formaram um comit conjunto (IsO/Iec jtc 1). um subcomit chamado Interconnection of Information technology equipment elaborou a norma para cabeamento estruturado IsO/Iec 11801. essa norma especifica um cabeamento genrico para uso em edifcios comerciais que pode compreender um ou mais prdios em um campus, em reas de raio at 3 km e at 1.000.000 m2 de espao de escritrios, atendendo entre 50 e 50.000 pessoas. a edio atual foi publicada em 2002.
ANSI/TIA/EIA
no mbito de cabeamento e componentes, a ansI/tIa/eIa tem representado o grande avano nesta rea. um grupo foi formado em 1985 num esforo para enderear a falta de padres para cabeamento para prdios. sua inteno inicial foi identificar os requisitos mnimos que suportaro os ambientes multiprodutos e multiprovedores, permitindo o planejamento e a instalao de sistemas de telecomunicao sem o conhecimento do equipamento especfico a ser instalado. Desde ento, estas normas so continuamente atualizadas atravs de revises a cada 5 anos e a emisso de adendos e boletins tcnicos (tsBs) permitindo que as normas estejam sempre alinhadas e atualizadas em relao a evoluo da indstria.
184
Topologia:
estrela hierrquica (cada cross-connect horizontal cabeado a um cross-connect principal ou a um cross-connect intermedirio e ento a um cross-connect principal). no se passa mais do que um cross-connect do cross-connect horizontal para alcanar o cross-connect principal. cabeamentos para topologias barramento ou anel sero feitos se necessrios, em adio topologia estrela.
Cross-Connect x Interconexo
Cabos de manobra
Devem atender aos requisitos de transmisso horizontal. Os Patch Cords no podem ser confeccionados em campo.
Salas de Equipamentos
So consideradas distintas dos armrios de telecomunicaes devido a sua natureza ou a complexidade do equipamento que nelas esto contidas. Podem cumprir algumas ou todas as funes de um armrio de telecomunicao. Deve ser projetada conforme ANSI/TIA/EIA-569-B. Oferecem um ambiente controlado para armazenar equipamentos de telecomunicaes, hardware de conexo, facilidades de aterramento e aparatos para proteo onde for aplicvel. Pode conter o cross-connect principal ou cross-connect intermedirio e cross-connect horizontal para partes do edifcio. Frequentemente contm terminais auxiliares.
Cross-Connects
Cabos para equipamentos que consolidam muitas portas num nico conector (exemplo: conector de 25 pares) so terminados num hardware de conexo designado (especficos para o sistema). O hardware designado ento interconectado para terminaes horizontais ou backbone. Interconexes Cabos de equipamentos que estendem uma aparncia de porta nica (exemplo: hub modular) so permanentemente terminados ou interconectados diretamente s terminaes horizontais ou backbone.
Distncias:
O comprimento do cabo horizontal deve estar limitado a um mximo de 90 metros para todos os tipos. Patch Cords no cross-connect horizontal no devem exceder o comprimento de 5 metros. Para locais onde so aplicadas tomadas multimdia, o comprimento no deve exceder a 20 metros.
Armrios de Telecomunicaes
Devem ser projetados conforme a ANSI/TIA/EIA-569 B. Funo primria da terminao para distribuio do cabeamento horizontal (cross-connects horizontais). Podem conter cross-connects principais ou intermedirios. Proporciona um ambiente controlado para armazenar equipamentos de telecomunicaes, hardware de conexo.
Pontos de Transio/Consolidao:
No mximo um ponto de transio e 1 ponto de consolidao permitido para cada enlace horizontal. Um comprimento de 3 metros permitido para patch cords com a finalidade de conectar o equipamento na rea de trabalho. O comprimento total de cordes (patch cords) no deve exceder 10 metros. Obs.: seguindo-se a orientao de 5m e 3m ser evitada a obrigatoriedade de verificar se a limitao de 10m ser excedida quando forem realizadas modificaes.
185
186
CABEAMENTO HORIZONTAL
estende-se desde os conectores/tomadas da rea de trabalho ao cross-connect horizontal instalado na sala de telecomunicaes. a topologia fsica uma estrela (cada conector/tomada de telecomunicaes tm a sua prpria posio mecnica terminal no cross-connect horizontal no armrio de telecomunicao). Inclui: Cabos horizontais. Conectores/tomadas de telecomunicaes. Terminais mecnicos no armrio de telecomunicaes. Patch Cords na sala de telecomunicaes.
Mximo compriMximo commento dos caprimento do bos na rea de cabo na rea de trabalho, Patch trabalho cords e cabo do equipamento W C 5 10 9 14 13 18 17 22 22 27
rea de Trabalho
Os componentes estendem-se desde tomadas/conectores de telecomunicaes do cabeamento horizontal at os equipamentos da estao (estes se encontram fora do escopo das normas). adaptadores necessrios tais como: divisores, baluns, filtros etc. devem ser externos ao conjunto tomada/ conector.
Categoria 5e: at 100 MHz. (com requisitos adicionais); Categoria 6: at 250 MHz. equivalente classe e da IsO; Categoria 6A: at 500 MHz. Obs.: fortemente recomendado que as novas instalaes
sejam especificadas para satisfazer os requisitos da categoria 6.
Jumpers Cross-Connect
Devem atender aos requisitos de transmisso horizontal. Cdigo de cor: um condutor branco e um outro condutor decolorao distinta como o vermelho ou azul. Os Patch Cords no podem ser confeccionados em campo.
tipo de Fibra OM1 OM2 OM3 OM1 OM2 OM3 G-652B / G652D
atenuao Mxima (dB/km) 3,5 3,5 3,5 1,5 1,5 1,5 0,5
Prticas de Instalao
Descasque o isolamento do cabo somente o suficiente para aterminao e mantenha os pares tranados o mais perto possvel do ponto de terminao mecnica. A distncia mxima destranada do par na conexo no deve ser maior que 13 mm. Mantenha um raio de curvatura mximo de 4 vezes o dimetro do cabo (cabos de 4 pares). Use braadeiras com folga e em intervalos no regulares. Evite o tracionamento excessivo do cabo.
Patch Cord
Condutores tranados especificamente para terem flexibilidade. Cabos que atendem aos requisitos de performance de transmisso horizontal (so permitidos valores de atenuao 20% acima dos permitidos para os cabos permanentes horizontais e de backbone). Dimetro de condutor isolado recomendado: 0,8 mm at 1 mm, mximo = 1,2 mm. Terminais T568A ou T568B em ambas as extremidades. Use mtodos apropriados para acomodar os cabos: - Braadeiras para fixao - Bandejas para acomodar cabos - Painis para gerenciamento dos cabos - Bandas removveis de velcro No tora o cabo demais, isto pode provocar o rompimento da capa. No exceda 11 kgf de tenso de tracionamento No use um grampeador revlver para posicionar cabos.
Os cabos devem estar de acordo com as normas vigentes. acessrios de conexo a identificao visual dos conectores e adaptadores de fibras multimodo deve ser de cor bege enquanto que para os conectores e adaptadores de fibras monomodo a cor azul. as tomadas de telecomunicaes devem ser capazes de acomodar duas fibras pticas e suas terminaes e devem permitir a fixao do cabo com um raio de curvatura mnimo de 25mm. Os patch panels devem permitir a fixao em parede ou rack e possibilitar a acomodao e manuseio dos cabos de fibra ptica e gerenciamento de cordes pticos. um patch panel deve ser projetado para: Meio de cross-connect entre cabos e patch cords. Meio de conexo entre equipamentos e o cabeamento ptico. Meios de identificao do cabeamento para administrao de acordo com a ansI/tIa/eIa-606. Meio de acesso para medio e monitoramento do cabeamento ptico. Meio de proteo para conectores e adaptadores de acidentes.
187
188
Os prdios so dinmicos; Os sistemas de telecomunicaes e os meios so dinmicos; Telecomunicao mais do que voz e dados. embora a norma trate somente do aspecto das telecomunicaes do projeto do edifcio, este padro influencia significa-tivamente o projeto de outros servios do edifcio, tais como a energia eltrica e o Hvac. esta norma indica os elementos para espaos e percursos de telecomunicaes em construes, conforme abaixo: Percursos Horizontais; Percursos Verticais (Backbone); rea de Trabalho; Sala de Telecomunicaes; Sala de Equipamentos; Sala de Entrada de Servios; Armrios de Telecomunicaes. alm disto, a norma contm os seguintes anexos e informativos: Anexo A: Firestopping (normativo); Anexo B: seo de Informaes adicionais (Informativo); Anexo C: Guia para reduo de rudos (Informativo); Anexo D: Bibliografia e referncias (informativo).
rea de Trabalho
espao interno de um edifcio onde um ocupante interage com dispositivos de telecomunicaes.
Tomadas de Telecomunicaes
Localizao do ponto de conexo entre o cabo horizontal e os dispositivos de conexo do cabo na rea de trabalho. Refere-se caixa (alojamento) ou espelho em geral, ao contrrio das tomadas incluindo os conectores de telecomunicaes individuais. necessrio um ponto no mnimo, por rea de trabalho (duas tomadas por rea de trabalho). A alocao de espao de trabalho tipicamente uma a cada 10m2. Pelo menos uma tomada de energia deve ser instalada perto de cada tomada de telecomunicaes.
Percursos Horizontais
Implicam em infra-estruturas para a instalao de cabo de telecomunicaes proveniente do armrio de telecomunicaes e destinado a uma tomada/conector de telecomunicaes. Os percursos horizontais podem ser dos tipos: canaleta sob o piso, piso de acesso, condute, bandejas e tubulaes de fiao, forro e permetro. As diretrizes e os procedimentos de projeto so diretamente especificadas para esses tipos de percursos. Percursos verticais (Backbones) Consistem nos percursos internos (dentro de um edifcio) e entre edifcios (externos).
Sala de Telecomunicaes
Dedicado exclusivamente infra-estrutura das telecomunicaes. Equipamentos e instalaes estranhos s telecomunicaes no devem ser instalados nos armrios de telecomunicaes, nem passar atravs ou entrar neles. Mnimo de uma sala por andar. Devem ser providenciadas salas adicionais para cada rea acima de 1.000 m2 sempre que: - a rea atendida do andar for maior que 1.000 m2. - a distncia horizontal ultrapasse 90 m.
Armrio de Telecomunicaes
Espao dedicado s funes relacionadas a servios de telecomunicaes . O Armrio de Telecomunicaes deve ser capaz de conter o equipamento de telecomunicao, os cabos e os painis de conexo (cross-connect). Mnimo de um armrio por andar. Devem atender reas de at 335 m2. Deve atender a norma EIA-310-D.
Sala de Equipamentos
espao direcionado para equipamentos de telecomunicaes. acomoda somente equipamentos diretamente relacionados com o sistema de telecomunicaes e os sistemas de suporte ambiental correspondentes.
Dimensionamento:
Para atender aos requisitos conhecidos do equipamento especfico. se o equipamento for desconhecido planeje uma rea de 0,07 m de espao para cada 10 m de rea de trabalho. Dever ter uma rea mnima de 14 m. Para os edifcios com utilizao especial (hotis, hospitais, laboratrios) o dimensionamento deve basear-se no nmero de estaes de trabalho do seguinte modo: n de estaes de trabalho at 100 De 101 a 400 De 401 a 800 De 801 a 1.200 rea (m) 14 37 74 111
Espao Mnimo em Parede para Equipamento e Terminao Espao Bruto rea atendida (m) 10.000 20.000 40.000 50.000 60.000 80.000 100.000 rea atendida (m) 1.000 2.000 4.000 5.000 6.000 8.000 10.000 Dimenses da sala (mm) 3.660 x 1.930 3.660 x 2.750 3.660 x 3.970 3.660 x 4.775 3.660 x 5.588 3.660 x 6.810 3.660 x 8.440 comprimento da Parede (mm) 990 1.060 1725 2.295 2.400 3.015 3.630
189
190
Requisitos Internos
so todos os parmetros relacionados aos componentes de um canal e depois do canal completo. este canal pode ser testado ainda como canal e como Permanent link. Perda de Insero de cabos (IL) Near End Cross Talk - (NEXT) PowerSum Near End Cross Talk (PSNEXT) Attenuation to Cross Talk Far end (ACRF) Power Sum Attenuation to Cross Talk Far end (PSACRF) Far End Cross Talk (FEXT) Return Loss (RL) Propagation Delay (Delay skew) Tranverse Conversion Loss (TCL) Tranverse Conversion transfer Loss (TCTL) Resistncia DC desbalanceada Dentre as caractersticas de transmisso cabe destacar as medidas de Alien Cross Talk. O parmetro Alien CrossTalk simula a interferncia existente entre os cabos em uma instalao. esta medida consiste em avaliar a performance do cabo/ canal em relao a interferncia dos cabos adjacentes. a norma estabelece a configurao 6 ao redor de 1 mostrada abaixo. nestas configuraes so feitas as seguintes medidas:
rea de Trabalho
Armrio de Telecomunicaes, onde normalmente se encontra o cross-connect horizontal; Salas de Equipamentos, Principal e Intermedirias, onde se localizam os cross-connect principal e intermedirios, respectivamente; Sala de Entrada de Servios.
esta norma estabelece os requisitos especficos mnimos para cabeamento, cabos, cabos de manobra, connecting hardware, para suportar aplicaes com a Ieee 10GBase-t em lances de at 100 metros. alm desta norma todos os componentes de um cabeamento cat6a devem atender os requisitos das normas eIa/tIa 568. so especificados testes para o canal e enlace. O teste de enlace compreende entre o cross-connect horizontal (por exemplo patch panel), o cabo horizontal e a tomada de telecomunicaes e o teste de canal inclui os patch cords.
Cabeamento e componentes
categoria 6a aplicada para um cabeamento (cabos e componentes) cuja caracterstica de transmisso especificada at 500MHz para os parmetros internos e externos. estes parmetros so definidos no prximo item.
Requisitos de Transmisso
anexos com os descritivos dos ensaios de componentes e de performance
Glossrio
Adaptador duplex de fibra ptica: dispositivo mecnico projetado para alinhar e unir dois conectores duplex Administrao: metodologia que define os requisitos de documentao para administrar o sistema de cabeamento e seus componentes, a identificao dos elementos funcionais e os processos que requerem movimentaes, acrscimos e modificaes Aplicao: sistema, incluindo seu mtodo de transmisso associado, que suportado pelo cabeamento de telecomunicaes rea de trabalho: espao do edifcio no qual os ocupantes interagem com o equipamento terminal de telecomunicaes rea de trabalho individual: espao mnimo no edifcio que seria reservado a um ocupante Atenuao: perda de potncia de um sinal devido sua propagao por um meio fsico qualquer Atenuao de acoplamento: a relao entre a potncia transmitida atravs dos condutores e a potncia de pico mxima irradiada, conduzida e gerada por correntes de modo comum Backbone de campus: cabo que conecta o distribuidor de campus ao(s) distribuidor(es) de edifcio nOta Os cabos de backbone de campus podem tambm conectar diretamente os distribuidores de edifcio Backbone de edifcio: cabo que conecta o distribuidor de edifcio ao distribuidor de piso Cabeamento: sistema de cabos, cordes e hardware de conexo para telecomunicaes, que pode suportar a conexo de equipamentos de tecnologia da informao Cabeamento de fibra ptica centralizado: tcnica de distribuio de cabeamento ptico que prev o atendimento da rea de trabalho com fibras pticas a partir de um nico ponto centralizado no edifcio Cabeamento genrico: sistema de cabeamento estruturado de telecomunicaes, com capacidade de suportar um amplo espectro de aplicaes nOta O cabeamento genrico pode ser instalado sem conhecimento prvio dos requisitos das aplicaes. Cabo: conjunto de uma ou mais unidades de cabos do mesmo tipo e categoria, protegido por uma capa externa nOta este pode incluir, ainda, uma blindagem geral. Cabo balanceado: cabo constitudo de um ou mais elementos de cabo metlico simtrico (pares ou quadras tranadas) Cabo balanceado blindado: cabo balanceado com uma blindagem geral e/ou blindagem por pares Cabo balanceado no-blindado: cabo balanceado sem blindagem Cabo de fibra ptica (ou cabo ptico): cabo composto por uma ou mais fibras pticas Cabo do CP: cabo que conecta o ponto de consolidao (s) tomada(s) de telecomunicaes Cabo hbrido: conjunto de duas ou mais unidades de cabos e/ou cabos de diferentes tipos ou categorias, cobertos por uma capa externa
191
Glossrio
192
nOta O conjunto pode ser coberto por uma blindagem geral. Cabo horizontal: cabo que conecta o distribuidor de piso s tomadas de telecomunicaes Cabo horizontal permanente: cabo que conecta o distribuidor de piso ao ponto de consolidao se existir, ou tomada de telecomunicaes (tO) se no existir um cP Campus: local que contm um ou mais edifcios Canal: via de transmisso ponta-a-ponta conectando dois equipamentos de aplicao especfica nOta Os cordes de equipamento e da rea de trabalho fazem parte do canal. Conector duplex de fibra ptica: dispositivo mecnico projetado para a terminao de duas fibras Conector ptico compacto: conector de fibra ptica projetado para a terminao de duas fibras com dimenses similares as de um conector usado no cabeamento balanceado Conexo: unio de dispositivos ou combinao de dispositivos incluindo as terminaes usadas para conectar os cabos ou elementos do cabo a outros cabos, elementos do cabo ou equipamento de aplicao especfica Conexo cruzada: arranjo que possibilita a terminao de elementos do cabo basicamente atravs de patch cords ou jumpers Cordo: cabo, unidade de cabo ou elemento do cabo com no mnimo uma terminao Cordo da rea de trabalho: cordo para conexo da tomada de telecomunicaes ao equipamento terminal Cordo de equipamento: cordo para interconexo do equipamento ativo ao distribuidor Desvio de perda de insero: diferena entre a atenuao estimada de um enlace ou canal e atenuao medida Diferena de atraso de propagao: a diferena de atraso de propagao entre os pares mais rpido e mais lento dentro de um mesmo cabo balanceado de quatro pares Distribuidor: termo empregado para o conjunto de componentes (tais como patch panels e patch cords) usados para conectar cabos Distribuidor de campus: distribuidor a partir do qual origina-se o cabeamento de backbone de campus Distribuidor de edifcio: distribuidor no qual terminam os cabos do backbone de edifcio, onde podem ser feitas conexes com os cabos do backbone de campus Distribuidor de piso: elemento usado para a distribuio do cabeamento horizontal do piso em que se encontra e o
backbone de edifcio Elemento do cabo: menor unidade de construo (por exemplo, par, quadra ou fibra nica) em um cabo nOta um elemento de cabo pode conter uma blindagem. Emenda: a unio de condutores metlicos ou fibras pticas Enlace:se associado a enlace do cP ou enlace permanente, ver enlace do cP e enlace permanente Enlace do CP: parte permanente da ligao entre o distribuidor de piso e o ponto de consolidao, incluindo o cabo e o hardware de conexo em cada extremidade Enlace permanente:segmento de cabo entre a tomada de telecomunicaes e o distribuidor de piso Guia de polarizao: dispositivo guia para a correta insero do conector Hardware de conexo: o hardware de conexo consiste em um componente ou combinao de componentes usados para conectar cabos ou elementos do cabo Infraestrutura de entrada: local de entrada de todos os servios mecnicos e eltricos necessrios para o ingresso de cabos de telecomunicaes no edifcio ou em um complexo de edifcios, em conformidade com as regulamentaes especficas Interconexo: conexo direta entre o equipamento ativo e o subsistema de cabeamento Interface: ponto no qual as conexes so feitas com o cabeamento genrico Interface de rede externa: ponto de demarcao entre as redes pblica e privada Jumper: cabo, unidade de cabo ou elemento de cabo sem conectores usado para estabelecer uma interligao em uma conexo cruzada Patch Cord: cordo com conectores modulares em ambas as extremidades usado para estabelecer conexes em um patch panel Patch panel: painel com vrias tomadas usado para a distribuio dos subsistemas de cabeamento Par: linha de transmisso balanceada de dois condutores Par tranado: elemento do cabo que consiste de dois condutores isolados tranados juntamente com um passo de toro regular para formar uma linha de transmisso balanceada. Perda de converso longitudinal:relao entre as correntes de modo diferencial e comum medidas entre pares adjacentes na mesma extremidade de um cabo Perda de converso transversal: relao entre a
potncia de sinal de modo comum e a potncia injetada do sinal de modo diferencial Perda de insero: dB, atenuao devida insero de componentes do cabeamento em um canal Perda de transferncia de converso longitudinal: relao entre as correntes de modo diferencial e comum medidas entre pares adjacentes em extremidades opostas de um cabo Ponto de consolidao: ponto de conexo no sistema de cabeamento horizontal situado entre o distribuidor do andar e a tomada de telecomunicaes Preenchimento total de ncleo (OFL): trata-se de um mtodo de medio da largura de banda das fibras multimodo. neste mtodo, o equipamento de medio simula um leD que excita todos os modos da fibra permitindo a medio de sua largura da banda. Quadra: elemento do cabo que compreende quatro condutores isolados tranados conjuntamente. Sala de equipamentos: sala destinada a abrigar distribuidores e equipamentos de aplicao especfica
nOta: este espao dedicado aos equipamentos ativos de uso comum de todos os usurios da rede. Sala de telecomunicaes: espao destinado a acomodar equipamentos de telecomunicaes, terminaes de cabos, interconexes e conexes cruzadas Tomada de telecomunicaes: dispositivo de conexo fixo onde o cabo horizontal terminado na rea de trabalho Tomada de telecomunicaes multiusurio: dispositivo nico com vrias tomadas de telecomunicaes com a finalidade de atendimento de usurios de uma mesma rea de trabalho nOta: aplica-se quando utilizadas instalaes em ambientes abertos (tipicamente escritrios comerciais sem paredes divisrias) Unidade do cabo: conjunto nico de um ou mais elementos de cabo do mesmo tipo e categoria. nOta 1 a unidade de cabo pode conter uma blindagem. nOta 2 um feixe de cabos pode ser considerado um exemplo de unidade do cabo.
Referncias normativas:
IEC 60512-2:1985, Electromechanical components for electronic equipment; basic testing procedures and measuring methods Part 2: General examination, electrical continuity and contact resistance tests, insulation tests and voltage stress tests Amendment 1 (1994) IEC 60512-25-1, Connectors for electronic equipment Tests and measurements Part 25-1: Test 25a Crosstalk ratio IEC 60512-25-2:2002, Connectors for electronic equipment Tests and measurements Part 25-2: Test 25b Attenuation (insertion loss) IEC 60512-25-4:2001, Connectors for electronic equipment Tests and measurements Part 25-4: Test 25d Propagation delay IEC 60512-25-5, Connectors for electronic equipment Basic tests and measurements Part 25-5: Test 25e Return loss IEC 60603-7:1996, Connectors for frequencies below 3 MHz for use with printed boards Part 7: Detail specification for connectors, 8-way, including fixed and free connectors with common mating features, with assessed quality IEC 60603-7-1:2002, Connectors for electronic equipment Part 7-1: Detail specification for 8-way, shielded free and fixed connectors, with common mating features, with assessed quality IEC 60603-7-7:2002, Connectors for electronic equipment Part 7-7: Detail specification for 8-way, shielded, free and fixed connectors, for data transmission with frequencies up to 600 MHz (category 7, shielded) IEC 60825 (all parts), Safety of laser products IEC 60874-1:1999, Connectors for optical fibres and cables Part 1: Generic specification IEC 60874-14 (all parts), Connectors for optical fibres and cables Part 14: Sectional specification for fibre optic connector Type SC IEC 60874-19 (all parts), Connectors for optical fibres and cables Part 19: Sectional specification for fibre optic connector Type SC (Duplex) IEC 60874-19-1:1999, Connectors for optical fibres and cables Part 19-1: Fibre optic patch cord connector type SC-PC (floating duplex) standard terminated on multimode fibre type A1a, A1b Detail specification
Glossrio
193
194
IEC 60874-19-2:1999, Connectors for optical fibres and cables Part 19-2: Fibre optic adaptor (duplex) type SC for singlemode fibre connectors Detail specification IEC 60874-19-3:1999, Connectors for optical fibres and cables Part 19-3: Fibre optic adaptor (duplex) type SC for multimode fibre connectors Detail specification IEC/PAS 61076-3-104:2002, Connectors for electronic equipment Part 3-104: Detail specification for 8-way, shielded free and fixed connectors, for data transmissions with frequencies up to 600 MHz IEC 61935-2, Generic cabling systems Specification for the testing of balanced communication cabling in accordance with ISO/IEC 11801 Part 2: Patchcords and work area cords ISO/IEC TR 14763-1, Information technology Implementation and operation of customer premises cabling Part 1: Administration ISO/IEC TR 14763-2, Information technology Implementation and operation of customer premises cabling Part 2: Planning and installation ISO/IEC TR 14763-3, Information technology Implementation and operation of customer premises cabling Part 3: Testing of optical fibre cabling ISO/IEC 15018, Information technology Generic cabling for homes ISO/IEC 18010:2002, Information technology Pathways and spaces for customer premises cabling ITU-T Rec. G.652:1993, Characteristics of a single-mode optical fibre cable NBR 13989 Cabo ptico subterrneo - determinao do desempenho quando submetido ao ensaio de coeficiente de atrito esttico NBR 13990 Cabo ptico subterrneo - determinao do desempenho quando submetido vibrao NBR 14103 Cabo ptico dieltrico subterrneo NBR 14159 Cabo ptico com ncleo geleado protegido por capa apl especificao NBR 14160 Cabo ptico dieltrico areo auto-sustentado especificao NBR 14161 Cabo ptico dieltrico de emergncia especificao NBR 14433 Conectores montados em cordes ou cabos de fibras pticas e adaptadores especificao NBR 14565 Procedimento bsico para elaborao de projetos de cabeamento de telecomunicaes para rede interna estruturada NBR 14566 Cabo ptico dieltrico para aplicao subterrnea em duto e area espinado especificao NBR 14584 Cabo ptico com proteo metlica para instalaes subterrneas - verificao ou suscetibilidade a danos provocados por descarga atmosfrica - mtodo de ensaio NBR 14589 Cabo ptico com proteo metlica para instalaes subterrneas - determinao da capacidade de drenagem de corrente - mtodo de ensaio NBR 14703 Cabos de telemtica de 100 ohms para redes internas estruturadas - especificao NBR 14771 Cabo ptico interno especificao NBR 14772 Cabo ptico de terminao especificao NBR 14773 Cabo ptico dieltrico protegido contra ataque de roedores para aplicao em linhas de dutos especificao NBR 14774 Cabo ptico dieltrico protegido contra ataque de roedores para aplicao enterrada especificao NBR 15108 Cabo ptico com ncleo dieltrico e proteo metlica para aplicao em linhas de dutos NBR 15110 Cabo ptico com ncleo dieltrico e proteo metlica para aplicao enterrado NBR 6814 Fios e cabos eltricos ensaio de resistncia eltrica NBR 9130 Fios e cabos telefnicos ensaio de desequilbrio resistivo NBR 9133 cabos telefnicos ensaio de atenuao de sinal de transmisso mtodo de ensaio
BRASIL
ESCRITRIO NACIONAL DE VENDAS SO PAULO - SP Av. das Naes Unidas, 11.633 14 andar - Ed. Brasilinterpart CEP: 04578-901 Tel.: (11) 5501-5711 Fax: (11) 5501-5757 E-mail: saopaulo@furukawa.com.br BELO HORIZONTE - MG Cel.: (31) 9126-7066 E-mail: belohorizonte@furukawa.com.br BRASLIA - DF Cel.: (61) 8102-1919 E-mail: brasilia@furukawa.com.br CURITIBA - PR Tel.: (41) 3341 4275 E-mail: curitiba@furukawa.com.br
PORTO ALEGRE - RS Cel.: (51) 8206-5609 E-mail: portoalegre@furukawa.com.br RECIFE - PE Cel.: (81) 9631-8915 E-mail: recife@furukawa.com.br RIO DE JANEIRO - RJ Cel.: (21) 8128-2915 E-mail: riodejaneiro@furukawa.com.br SALVADOR - BA Cel.: (71) 9205-9877 E-mail: salvador@furukawa.com.br
CENTROS DE DISTRIBUIO
BRASIL
RECIFE - PE Rodovia BR 101 Sul km 80,7 Anexo A, Setor K - Prazeres CEP: 54345-160 Jaboato dos Guararapes - PE VITRIA - ES Rodovia BR 101 Norte km 10 Lote A - Parte - Carapina CEP: 29160-901 - Serra - ES
PANAM
Forwarding and Logistic Solution France Field - Zona Libre de Coln, Panam
ARGENTINA
BUENOS AIRES Ruta Nacional 2, km 37,5 Centro Industrial Ruta 2 Berazategui Provncia de Buenos Aires Tel.: (54 22) 2949-1930
ARGENTINA
ESCRITRIO - BUENOS AIRES Moreno, 850 - Piso 15B Cd. Postal C1091AAR Ciudad Autnoma de Buenos Aires Tel.: (54 11) 4331-2572 E-mail: argentina@furukawa.com.br
0800 412100
www.furukawa.com.br
As informaes tcnicas contidas neste catlogo foram baseadas em dados vigentes na poca de sua impresso. Durante a utilizao deste material promocional poder haver alterao sempre que as normas e o processo de fabricao forem modicados, assim como cdigos e descries dos produtos. Fotos meramente ilustrativas. Edio/reviso 3 - junho 2011.