PENDENCIAS 2022 CHECK LIST FO 060 330 003 - INSPE

O.S. DATA DE ABERTURA

1993730 9/3/2022

1993729 9/3/2022
1993734_x001E_ 9/3/2022
1993745 9/4/2022

1993750 9/4/2022
1993744 9/4/2022
1993748 9/4/2022

2000256 9/11/2022

2000253 9/11/2022

2000255 9/11/2022
2021736 10/1/2022
2021739 10/1/2022

2021748 10/1/2022
2021754 10/1/2022
2055208 11/2/2022
2055214 11/2/2022

2069329_x001E_ 11/16/2022
2088640 12/4/2022
2088641 12/4/2022
2088643 12/4/2022

2088645 12/4/2022
2088648 12/4/2022
2088649 12/4/2022

2088647 12/4/2022
2088669 12/4/2022

2088671 12/4/2022
2088672 12/4/2022
2088639 12/4/2022
2101719 12/16/2022

2101717 12/16/2022
2101720 12/16/2022
2114021 12/28/2022

2114066 12/28/2022
2114016 12/28/2022
2114055 12/28/2022
2114008 12/28/2022
2114010 12/28/2022

PENDENCIAS 2022 CHECK LIST FO 060 330 003 - INSPE


O.S. DATA DE ABERTURA

1931675 7/2/2022

2088670 12/4/2022
2114008 12/28/2022
2114010 12/28/2022

2114054 12/28/2022
PENDENCIAS 2022 CHECK LIST FO 060 330 003 - INSPEÇÃO EQUIP. DETECÇÃO DE AMON
DESCRIÇÃO DO SERVIÇO
EQ99 L03 SIRENE DA BOTOEIRA AO LADO DO DESINFETANTE DE CAMINHOES DA RECPCAO DE
AVES NAO ACIONA

EQ103 L06 SIRENE DA BOTOEIRA DA ESCALDAGEM L1 EM FRENTE A SALA DE PATAS NAO ACIONA
EQ103 L07 SIRENE DA BOTOEIRA DO MEZANINO NAO ACIONA
EQ03 L05 SUBSTITUIR BOTOEIRA DE EMERGENCIA DO LOCAL PROCURAR BOMBEIRO SAMUEL
_x001C_EQ10 L05 BOTOEIRA FAIXADA AO LADO DA PORTA DE ACESSO DOS VISITANTES ESTA
SEM VALOR
EQ42 L05 SENSOR DE FUMACA NO ESCRITORIO DA PRODUCAO DO SIF ESTA SOLTO
EQ64 L07 SENSOR DE FUMACA FABRICA DE GELO 1 ESTA EM FALHA VALOR 08
EQ95 L04 SIRENE DA BOTOEIRA NO TUNEL DE ENTRADA DOS FUNCIONARIOS AO LADO DA
ESCADA ESTA COM DEFEITO
EQ95 L02 SIRENE DA BOTOEIRA DO VESTIARIO BRANCO FEMININO APRESENTA DEFEITO NO
SISTEMA
_x001C_EQ36 L02 SENSOR DE FUMACA LAVANDERIA BRANCA ESTA COM VALOR 44 PRE ALARME
E NAO RESETA NO SISTEMA
EQ98 L03 SIRENE DA BOTOEIRA AO LADO DO BANHEIRO DA RECEPCAO DE AVES NAO ACIONA
EQ94 L05 SIRENE DA BOTOEIRA DO RESFRIAMENTO 1 NAO ACIONA
EQ113 L05 SIRENE DA BOTOEIRA NO CORTES 2 PROXIMO A SAIDA PARA O CORREDOR NAO
ACIONA
EQ100 L06 SIRENE DA BOTOEIRA DA ESCALDAGEM L2 NAO ACIONA
EQ07 L06 BOTOEIRA DO CARREGAMENTO DE GAIOLAS NAO ACIONA
EQ13 L16 SENSOR DE FUMACA PORAO DA UIC MEIO ESTA SEM VALOR
EQ99 L02 SIRENE DA BOTOEIRA DO CORREDOR DA LAVANDERIA VERDE ACESSO A UFO ESTA
DANIFICADA
EQ14 L04 BOTOEIRA DENTRO DA CAMARA C EXPEDICAO NAO ACIONA
EQ96 L05 SIRENE AUDIO VISUAL DO RESFRIAMENTO L1 NAO ACIONA
EQ103, 104, E 105 DO LACO 05 SIRENES DAS BOTOEIRAS DA FACHADA NAO ACIONA
EQ98 L06 FAVOR TROCAR SIRENE DA BOTOEIRA DA ESCALDAGEM L2 DE LOCAL PROCURAR
BOMBEIRO SAMUEL
EQ12 L06 BOTOEIRA DA PENDURA NAO ACIONA
EQ14 L06 BOTOEIRA DA DESCARGA DE GAIOLAS RECEPCAO DE AVES NAO ACIONA
_x001C_EQ110 L05 SIRENE DA BOTOEIRA DO RESFRIAMENTO L2 PROXIMO A PORTA DE ACESSO
PARA A FABRICA DE GELO 2 NAO ACIONA
EQ65 L07 SENSOR DE FUMACA NA FABRICA DE GELO 1 ESTA SEM VALOR
_x001C_EQ97 L16 SIRENE DA BOTOEIRA DA SUBESTACAO DA UIC LADO EXTERNO SENTIDO DOCA
DO RECEBIMENTO NAO ACIONA
EQ17 L16 SENSOR DE FUMACA NO PORAO DA UIC ENTRADA ESTA COM VALOR 59
EQ47 L03 SENSOR DE FUMACA NO ALMOXARIFADO FUNDOS ESTA COM O VALOR 59
EQ100 L05 SIRENE DA BOTOEIRA DENTRO DO CMS ESTA EM FALHA NO SISTEMA
EQ94 L07 SIRENE AUDIO VISUAL NA EMBALAGEM PRIMARIA AO LADO DO BEBEDOURO ESTA
COM FALHA NO SISTEMA
EQ01 L15 BOTOEIRA DO EMPANAMENTO L2 ESTA EM FALHA VALOR 04
EQUIPAMENTOS DO LACO 4 ESTAO SEM VALOR
EQ02 L04 BOTOEIRA TUNEL DE ENTRADA DOS FUNCIONARIOS AO LADO DO ELEVADOR DE
PESSOAS PRECISA SER REALOCADA PARA OUTRO LOCAL
EQUIPAMENTOS DO LACO 05 ESTAO SEM VALOR
EQ07 L05 BOTOEIRA FACHADA LADO ESQUERDO ESTA SEM VALOR
EQUIPAMENTOS DO LACO 7 ESTAO SEM VALOR
EQUIPAMENTOS DO LACO 8 ESTAO SEM VALOR

PENDENCIAS 2022 CHECK LIST FO 060 330 003 - INSPEÇÃO EQUIP. DETECÇÃO DE AMON
DESCRIÇÃO DO SERVIÇO
EQ28 L04 DETECTOR DE AMONIA LOCALIZADO NA CENTRAL DE ASPIRACAO DA SALA DE PAINEIS
DO CORTES L1 ESTA COM O VALOR 17 NAO RESETA NO SISTEMA
EQ90 L09 PAINEL NA CASA DE MAQUINAS REFERENTE A ZONA L DOS DETECTORES DE NH3 DO
CONGELADOR DE PLACAS CMS ESTA EM FALHA
EQUIPAMENTOS DO LACO 7 ESTAO SEM VALOR
EQUIPAMENTOS DO LACO 8 ESTAO SEM VALOR
EQ16 L13 DETECTOR DE AMONIA DA ASPIRACAO LOCALIZADA NO DEPOSITO DE PAPELAO ESTA
SEM VALOR (DETECTOR LADO DIREITO)
EÇÃO EQUIP. DETECÇÃO DE AMONIA E INCENDIO
MAFOZ OBSERVAÇÃO EQUIPE RESPONSAVEL PELA EXECUÇÃO

FECHADA INCENDIO ELETRICA 1º TURNO

ABERTA INCENDIO ELETRICA 1º TURNO


ABERTA INCENDIO ELETRICA 1º TURNO
ABERTA INCENDIO ELETRICA 1º TURNO

FECHADA INCENDIO ELETRICA 1º TURNO


ABERTA INCENDIO ELETRICA 1º TURNO
ABERTA INCENDIO ELETRICA 2º TURNO

ABERTA INCENDIO ELETRICA 1º TURNO

ABERTA INCENDIO UTILIDADES

ABERTA INCENDIO UTILIDADES


FECHADA INCENDIO ELETRICA 1º TURNO
ABERTA INCENDIO ELETRICA 2º TURNO

ABERTA INCENDIO ELETRICA 2º TURNO


ABERTA INCENDIO
FECHADA INCENDIO ELETRICA 1º TURNO
ABERTA INCENDIO UIC

ABERTA INCENDIO UTILIDADES


FECHADA INCENDIO CASSIANO EXPEDIÇÃO
ABERTA INCENDIO ELETRICA 1º TURNO
FECHADA INCENDIO ELETRICA 1º TURNO

ABERTA INCENDIO ELETRICA 1º TURNO


ABERTA INCENDIO ELETRICA 1º TURNO
FECHADA INCENDIO ELETRICA 1º TURNO

ABERTA INCENDIO ELETRICA 2º TURNO


ABERTA INCENDIO ELETRICA 2º TURNO

ABERTA INCENDIO UIC PAULO


ABERTA INCENDIO UIC PAULO
ABERTA INCENDIO UTILIDADES
ABERTA INCENDIO ELETRICA 1º TURNO

ABERTA INCENDIO CASSIANO EXPEDIÇÃO


ABERTA INCENDIO UIC PAULO
ABERTA INCENDIO CASSIANO EXPEDIÇÃO

ABERTA INCENDIO UTILIDADES


ABERTA INCENDIO ELETRICA 1º TURNO
ABERTA INCENDIO UTILIDADES
ABERTA INCENDIO CASSIANO EXPEDIÇÃO
ABERTA INCENDIO CASSIANO EXPEDIÇÃO

EÇÃO EQUIP. DETECÇÃO DE AMONIA E INCENDIO


MAFOZ OBSERVAÇÃO EQUIPE RESPONSAVEL PELA EXECUÇÃO

ABERTA AMONIA MANUTENÇÃO SALA DE MAQUINAS

FECHADA AMONIA MANUTENÇÃO SALA DE MAQUINAS


ABERTA AMONIA MANUTENÇÃO SALA DE MAQUINAS
ABERTA AMONIA MANUTENÇÃO SALA DE MAQUINAS

ABERTA AMONIA MANUTENÇÃO SALA DE MAQUINAS


PENDENCIAS 2022 CHECK LIST FO 060 330 021 - I
O.S. DATA DE ABERTURA

1815042 2/26/2022

1979231 8/21/2022

1979223 8/21/2022

1979224 8/21/2022

1979225 8/21/2022

1979228 8/21/2022

1979230 8/21/2022

2006515 9/16/2022

2006553 9/16/2022

2006546 9/16/2022

2006549 9/16/2022

2006540 9/16/2022

2006544 9/16/2022

2016149 9/26/2022

2016197 9/26/2022
2016193 9/26/2022

2016184 9/26/2022

2016203 9/26/2022

2016204 9/27/2022

2041721 10/20/2022

2050492 10/28/2022
2060396 11/7/2022

2083260 11/29/2022
PENDENCIAS 2022 CHECK LIST FO 060 330 021 - INSPEÇÃO LUMINÁRIAS DE EMERG
DESCRIÇÃO DO SERVIÇO

REALIZAR A COLOCACAO DE UMA LUMINARIA DE EMERGENCIA DE BATERIA INTEGRADA NO


INTERNO DA PORTARIA PRINCIPAL/LUMINARIA DE COD 196772/ SERA NECESSARIO A
COLOCACAO DE UMA TOMADA PARA A ALIMENTACAO DA MESMA/ DUVIDAS TRATAR COMIGO
BOMBEIRO LUCAS BERENGUEL
REALIZAR A IMPLEMENTACAO DE UMA LUMINARIA DE EMERGENCIA DIRECIONAL COM
INDICATIVO DE SAIDA NO INTERNO DA PORTA DE SAIDA DA SALA DE SALADAS DO REFEITORIO/
LUMINARIA DE COD 124573 ATT BOMBEIRO LUCAS BERENGUEL
REALIZAE A IMPLEMENTACAO DE UMA LUMINARIA DE EMERGENCIA DIRECIONAL COM
INDICATIVO DE SAIDA NO INTERNO DA PORTA DE ACSSO A LAVANDERIA BRANCA/LUMINARIA DE
COD 124573 ATT BOMBEIRO LUCAS BERENGUEL
REALIZAR A IPLEMENTACAO DE UMA LUMINARIA DE EMERGENCIA COM INDICATIVO DE SAIDA
NO INTERNO DA PORTA DE ACESSO DA LAVANDERIA VERDE/ LUMINARIA DE COD 124573 ATT
BOMBEIRO LUCAS BERENGUEL
REALIZAR A IMPLEMENTACAO DE 01 REFLETOR DE COD 148908 NO INTERNO DA AREA SUJA DA
LAVANDERIA E 01 LUMINARIA COM INDICATIVO DE SAIDA NO INTERNO DA PORTA DE ACESSO A
AREA SUJA/ LUMINARIA DE COD 124573 ATT BOMBEIRO LUCAS
REALIZAR A IMPLEMENTACAO DE 1 REFLETOR DE COD 148908 NO INTERNO DA ZELADORIA E 1
LUMINARIA DIRECIONAL COM INDICATIVO DE SAIDA NO INTERNO DA PORTA DE ACESSO DA
ZELADORIA DE COD 124573 ATT BOMBEIRO LUCAS BERENGUEL

REALIZAR A IMPLEMENTACAO DE 01 REFLETOR DE COD 148908 NO INTERNO DO ALMOXARIFADO


DO REFEITORIO E 1 LUMINARIA DIRECIONAL COM INDICATIVO DE SAIDA DE COD 124573 NO
INTERNO DA PORTA DE EMERGENCIA TAMBEM DO ALMOXARIFADO DO REFEITORIO ATT
BOMBEIRO LUCAS BERENGUEL

VERIFICAR O MOTIVO PELO QUAL O O PAINEL 3170040 N2 ETA NAO ESTA REALIZANDO A
SIMULACAO DE QUEDA IMPOSSIBILITANDO A VERIFICACAO DE FUNCIONAMENTO DAS
LUMINARIAS DE EMERGENCIA CORRESPONDENTES AO BANCO DE BATERIAS DO LOCAL ATT
BOMBEIRO LUCAS
VERIFICAR O MOTIVO PELO QUAL A LUMINARIA DE EMERGENCIA NAO FUNCIONA NO INTERNO
DO VESTIARIO DO AUDITOR FISCAL DO SIF ATT BOMBEIRO LUCAS
REALIZAR A COLOCACAO DE UMA LUMINARIA DIRECIONAL COM INDICATIVO DE SAIDA SETA
PARA ESQUERDA EM FRENTE A PORTA DE ACESSO AO ESCRITORIO DO SIF/ LUMINARIA DE COD
124574 DUVIDAS A DISPOSICAO ATT BOMBEIRO LUCAS
REALIZAR A COLOCACAO DE UMA LUMINARIA DIRECIONAL COM INDICATIVO DE SAIDA DE COD
124573 NO INTERNO DA PORTA DE ACESSO AO VESTIARIO MASCULINO/FEMININO SIF DUVIDAS A
DISPOSICAO ATT BOMBEIRO LUCAS
REALIZAR A COLOCACAO DE UMA LUMINARIA DE EMERGENCIA A CIMA DA PORTA DE ACESSO DA
ENFERMARIA NA PARTE EXTERNA VOLTADA PARA A AMBULANCIA LUMINARIA DE CODIGO
137430 UTILIZAR DEVIDO SEU FOCO SER MAIS ABRANGENTE ATT BOMBEIRO LUCAS
REALIZAR A COLOCACAO DE DOIS 02 REFLETORES DE CODIGO 148908/ COLOCAR UM REFLETOR
EM CADA CORREDOR DE ACESSO A SALA DA FACULDADE/GERENCIA DUVIDAS A DISPOSICAO ATT
BOMBEIRO LUCAS
REALIZAR A SUBSTITUICAO DA LUMINARIA DE EMERGENCIA DIRECIONAL COM INDICATIVO DE
SAIDA LOCALIZADA NO INTERNO DA PORTA DE ACESSO DA PENDURA / UTILIZAR REFLETOR DE
COD 124573 DUVIDAS A DISPOSICAO ATT BOMBEIRO LUCAS
VERIFICAR O MOTIVO PELO QUAL A LUMINARIA DE EMERGENCIA DIRECIONAL COM INDICATIVO
DE SAIDA LOCALIZADA NA PORTA DE ACESSO AO RESFRIAMENTO DA LINHA 02 NAO ESTA
FUNCIONANDO/SUBSTITUIR SE NECESSARIO ATT BOMBEIRO LUCAS
VERIFICAR O MOTIVO PELO QUAL A LUMINARIA DE EMERGENCIA DIRECIONAL COM INDICATIVO
DE SAIDA LOCALIZADA NO INTERNO DA PORTA DE ACESSO DO CORTES L2 NÃO ESTA
FUNCIONANDO/ SUBSTITUIR SE NECESSARIO ATT BOMBEIRO LUCAS
REALIZAR A SUBSTITUICAO DA LUMINARIA DE EMERGENCIA DIRECIONAL COM INDICATIVO DE
SAIDA LOCALIZADA A CIMA DA PORTA DE EMERGENCIA DA EVISCERACAO L2 /SUBSTITUIR POR
LUMINARIA DE COD 124573 ATT BOMBEIRO LUCAS
REALIZAR O AJUSTE DA LUMINARIA DE EMERGENCIA LOCALIZADA NO INTERNO DA PORTA DE
ACESSO DA SALA DE ABASTECIMENTO IQF L2 / A MESMA ESTA SEM PARAFUSO E PENDURADA
NAO REALIZANDO SUA FUNCAO CORRETA DE ILUMINACAO ATT BOMBEIRO LUCAS
VERIFICAR O MOTIVO PELO QUAL A LUMINARIA DE EMERGENCIA LOCALIZADA A CIMA DA PORTA
DE EMERGENCIA DO IQF 3 NAO ESTA FUNCIONANDO / SUBSTITUIR SE NECESSARIO ATT
BOMBEIRO LUCAS
REALIZAR A SUBSTITUICAO DA LUMINARIA DE EMERGENCIA LOCALIZADA N INTERNO DO
ESCRITORIO DA EXPEDICAO/ SUBSTITUIR POR REFLETOR DE COD 148908 / ECORTAR A
TUBULACAO DEIXANDO CERCA DE 3M DO NIVEL DO CHAO ATT BPC LUCAS
VERIFICAR O MOTIVO PELO QUAL A LUMINARIA DE EMERGENCIA LOCALIZADA NA PORTA DE
ACESSO DO LADO COLORIDO DA NOVA SALA DOS BOMBEIROS/TEC SEGURANCA NAO ESTA DE
ACORDO/ A PRINCIPIO PARECE ESTAR SEM A FIACAO ATT BOMBEIRO LUCAS BERENGUEL
LUMINARIA DE EMERGENCIA DANIFICADA PORTA DE SAIDA CMS
REALIZAR A IMPLEMENTACAO DE UMA LUMINARIA COM INDICATIVO DE SAIDA DE COD 124573
NO INTERNO DA PORTA DE ACESSO A EMBALAGEM SECUNDARIA UIA/ DUVIDAS A DISPOSICAO
ATT BOMBEIRO LUCAS
INSPEÇÃO LUMINÁRIAS DE EMERGÊNCIA
MAFOZ OBSERVAÇÃO EQUIPE RESPONSAVEL PELA EXECUÇÃO

ELEIANE ESTAVA VERIFICANDO COM A


GERENCIA A QUESTAO DA AUTORIZAÇÃO UTILIDADES
PARA FURAR A LAGE, SERA QUE FOI VISTO?
ABERTA

UTILIDADES
ABERTA

UTILIDADES
ABERTA

UTILIDADES
FECHADA

UTILIDADES
FECHADA

UTILIDADES
FECHADA

UTILIDADES

FECHADA

UTILIDADES

FECHADA
UTILIDADES
FECHADA

UTILIDADES
FECHADA

UTILIDADES
FECHADA

UTILIDADES
FECHADA

UTILIDADES
ABERTA

ELETRICA 1º TURNO
ABERTA

ELETRICA 2º TURNO
FECHADA
ELETRICA 2º TURNO
FECHADA

ELETRICA 2º TURNO
FECHADA

ELETRICA 2º TURNO
ABERTA

ELETRICA 2º TURNO
ABERTA

EMBALAGEM CASSIANO
FECHADA

UTILIDADES
FECHADA
ABERTA ELETRICA 2º TURNO

ABERTA EMBALAGEM CASSIANO