| Unidade Internas
Unidades Internas Manual de Projeto
Cassette Compacto DC
1. Características....................................................................................................................................................................68
2. Especificações....................................................................................................................................................................70
3. Dimensões..........................................................................................................................................................................72
4. Espaço de Serviço..............................................................................................................................................................73
5. Esquema de Tubulação......................................................................................................................................................74
6. Esquema Elétrico................................................................................................................................................................75
7. Tabelas de Capacidades.....................................................................................................................................................77
8. Características Elétricas.....................................................................................................................................................81
9. Níveis de Ruído..................................................................................................................................................................81
10. Acessórios.........................................................................................................................................................................83
Dutado Standard
1. Características.................................................................................................................................................................. 111
2. Especificações..................................................................................................................................................................113
3. Dimensões........................................................................................................................................................................116
4. Espaço de Serviço............................................................................................................................................................118
5. Diagrama de Tubulação....................................................................................................................................................119
6. Esquema Elétrico..............................................................................................................................................................120
7. Curvas de Performance do ventilador..............................................................................................................................121
8. Tabelas de Capacidade.....................................................................................................................................................128
9. Características Elétricas...................................................................................................................................................134
10. Níveis de Ruído..............................................................................................................................................................134
11. Acessórios.......................................................................................................................................................................138
5
VRF MIDEA MDV4+ Unidades Internas Manual de Projeto
1. Características
• A pressão estática externa da unidade interna pode ser de até 200Pa (20mmca), o que permite a extensiva
utilização de dutos para aplicações que necessitem flexibilidade. O ar condicionado pode ser distribuído em toda
extensão da sala, até mesmo quando utilizado em ambientes com pé direito altos (6,5m). A distância máxima do
fornecimento de ar é de cerca de 14m.
Permite comprimento de
até 14 m de duto
Induto de ar de renovação
Un Id Ad E In TERn A
Insuflamento
Retorno
Permite insuflamento de
até 6,5m de altura em
relação ao solo
139
VRF MIDEA
MIDEA MDV4+
| Unidade Internas
Unidades Internas Manual de Projeto
• Graças ao motor de ventilador DC, a unidade duto de alta pressão estática pode satisfazer as recentes exigências
de certificação CE.
Teto
• Fácil acesso para manutenção e ao motor. Isso significa que o motor pode ser substituído sem a remoção da
unidade;
• Saída de sinal 12V para intertravamento com dispositivos externos.
• Entrada ON/OFF (contato seco, sem tensão) para intertravamento com dispositivo externos como, por exemplo,
chave de cartão de hotel.
• Estrutura da caixa de controle elétrica integrada para conveniência de instalação e manutenção.
140
VRF
VRF MIDEA MDV4+
| Unidade Internas
Unidades Internas Manual de Projeto
2. Especificações
Modelo MI-160T1/DHN1-BA MI-200T1/DHN1-BA
Alimentação V- Ph-Hz 220-240V - 1 - 50/60Hz
kW 16 20.0
Capacidade
Btu/h 54600 68200
Refrigeração
Consumo W 700 800
Corrente A 4.5 7.5
kW 17 22.5
Capacidade
Btu/h 58000 76800
Aquecimento
Consumo W 700 800
Corrente A 4.5 7.5
Modelo WZDK750-38GS-W WZDK750-38GS-W
Motor Ventilador Tipo DC MOTOR
Interno Marca Pansonic/ Welling Pansonic/ Nidec
Entrada W 680 790
Número de filas 4 4
Passo do tubo(a) × Passo da fila(b) mm 1×7/8 (25.4×22)
Espaçamento aleta mm 1.6 1.8
Serpentina Interna Aleta tipo Alumínio hidrófilo
Diâmetro Externo do Tubo e Tipo in (mm) 3/8 (Ф9.53) Tubo com ranhuras internas
Dimensão (LxAxP) 996×356×88 1125×512×88
Número de circuitos 7 20
m3/h 3400/2660/2400 4820/4660/4620
Vazão (A/M/B)
CFM 2002/1567/1413 2839/2744/2721
*Pressão estática nominal (Limites de operação) Pa 50(0~ 196) 62(40~200)
Nível de Ruído (A/M/B) dB(A) 54/52/50 57/53/50
Dimensão sem embalagem (L×A×P) mm 1300 × 420 × 690 1440 × 505 × 925
Unidade Interna Dim ensão com embalagem (L×A×P) mm 1436 × 450 × 768 1509 × 550 × 990
Peso Liq / Bruto kg 63/71 108/120
Fluido Refrigerante Tipo R410A
Válvula de Expansão EXV
Pressão de Projeto (A/B) MPa 4.4/2.6 4.4/2.6
Ф3/8/ Ф5/8 Ф3/8 (Ф9.53)/
Conexões de Líquido / Gás in (mm)
(Ф9.53/ Ф15.9) Ф5/8 (Ф15.9 )(×2)
Tubulações
Dreno in (mm) OD 63/64 (Ф25) OD 1-17/64 (Ф32)
Controlador com fio KJR-29B/BK-E
Controle
(6 metros de fio)
Notas:
1. Capacidades nominais de refrigeração são baseadas nas seguintes condições: Temperatura ar de retorno:
27°C (Bulbo Seco), 19°C (Bulbo Úmido); Temperatura externa: 35°C (Bulbo Seco); Tubulação equivalente de
referência: 7.5m (horizontal).
2. Capacidades nominais de aquecimento são baseadas nas seguintes condições: temperatura ar de retorno: 20°C
(Bulbo Seco), temperatura externa: 7°C (Bulbo Seco), 6°C (Bulbo Úmido); Tubulação equivalente de referência:
7.5m (horizontal).
3. *Cada modo de funcionamento (baixa/média/alta) tem seu respectivo limite de operação. Para maiores
informações, verificar seção 07 desse manual. Os riscos de selecionar uma unidade fora da faixa ideal incluem
níveis de ruído mais altos, baixo volume de fluxo de ar etc.
141
VRF MIDEA
MIDEA MDV4+
| Unidade Internas
Unidades Internas Manual de Projeto
Notas:
1. Capacidades nominais de refrigeração são baseadas nas seguintes condições: Temperatura ar de retorno:
27°C (Bulbo Seco), 19°C (Bulbo Úmido); Temperatura externa: 35°C (Bulbo Seco); Tubulação equivalente de
referência: 7.5m (horizontal).
2. Capacidades nominais de aquecimento são baseadas nas seguintes condições: temperatura ar de retorno: 20°C
(Bulbo Seco), temperatura externa: 7°C (Bulbo Seco), 6°C (Bulbo Úmido); Tubulação equivalente de referência:
7.5m (horizontal).
3. *Cada modo de funcionamento (baixa/média/alta) tem seu respectivo limite de operação. Para maiores
informações, verificar seção 07 desse manual. Os riscos de selecionar uma unidade fora da faixa ideal incluem
níveis de ruído mais altos, baixo volume de fluxo de ar etc.
142
VRF
VRF MIDEA MDV4+
| Unidade Internas
Unidades Internas Manual de Projeto
3. Dimensões
3.1. Unidades: MI-140T1/DHN1-BA e MI-160T1/DHN1-BA.
Vista frontal, vista superior e vista traseira: Unidade: in (mm)
SAÍdA dE AR
13-11/32(339mm)
3 -7/32 (82mm)
3-7/32 (82mm)
31
143
VRF MIDEA
MIDEA MDV4+
| Unidade Internas
Unidades Internas Manual de Projeto
Vista lateral:
• Vista esquerda
COnEXÃO TUBULAÇÃO
dE dREnO
(189mm)
COnEXÃO dA
7-7/16
TUBULAÇÃO dE 1-11/16
REFRIGERAnTE (43mm)
Ф9.53 (3/8)
(123mm)
4-27/32
COnEXÃO dA
TUBULAÇÃO dE
REFRIGERAnTE
Ф16 (5/8)
2-13/32(61mm)
(75mm)
2-15/16
COnEXÃO dA TABULAÇÃO
dO dREnO dE SEGURAnÇA
• Vista direita
Vista direita
2-1/16 (52mm)
19/32(15mm)
6-21/32
(169mm)
(123mm) (179mm)
7-1/16
1-3/32
(28mm)
27-7/32 (691mm)
4-27/32
7/16
(11mm)
1-3/8 (35mm)
(136mm)
5-11/32
4-29/32
144
(125mm)
VRF
VRF MIDEA MDV4+
| Unidade Internas
Unidades Internas Manual de Projeto
1121 75
60
96
343
Conexões de comunicação
entre unidade interena
e externa
Saída de ar
4-12*25
Suporte para
parafusos 1440
Caixa elétrica
4-Φ10 parafuso
Saída de
(configurar no local)
ar do duto
925
Conexão flangeada para
tubo de refrigerante Φ9.52 (3/8) Entrada de
ar do duto
66
1270
Entrada de ar
936 200
378
50
145
MCAC-VTSM-2017-01 Built in de alta pressão estática com motor dC
VRF MIDEA
MIDEA MDV4+
| Unidade Internas
Unidades Internas Manual de Projeto
Conexão da
tubulação de dreno
4 Espaços de serviço
Verificar
4. Espaço de Serviçose:
Verificar se:
• Há espaço suficiente
Há espaço para instalação
suficiente e manutenção;
para instalação e manutenção;
• éOhorizontal
O teto teto é horizontal e sua estrutura
e sua estrutura consegueconsegue
suportarsuportar o peso
o peso da da unidade
unidade interna; interna;
4 Espaços
• As entradas
ser a
e de
saídaseserviço
As entradas
menor
saídas
de
possível
depodem
ar não ar não estar
(10% -
podem
máximo
(10% - máximo de Ar Externo da vazão manual); de
estar obstruídas
obstruídas
Ar
e a influência
e a influência
Externo da vazão
do artem
do ar externo
manual)
externo tema que
que ser menor possível
Isolation booth
500mm or up
Espaço de manutenção
Maintenance space
600mm or up
Espaço de manutenção
Maintenance space
600mm* 600mm
Porta de verificação
checking port
5. Esquemas de Tubulação
5.1MI-140T1/DHN1-B,
Unidades:MI-160T1/DHN1-B
MI-140T1/DHN1-BA e MI-160T1/DHN1-BA.
motor
fan
T2B T1: Sensor de Temperatura do
flare nut
ambiente
gas side T2: Sensor de temperatura central da
T1 EXV
T2 serpentina
T2B: Temperatura na saída da
serpentina do evaporador
heat exchanger flare nut
liquid side
motor
fan
T1 gas side
T2
EXV
T1: Sensor de Temperatura do
T1
T2 ambiente
flare nut
T2: Sensor de temperatura central
da serpentina
liquid side
T2B: Temperatura na saída da
heat exchanger serpentina do evaporador
flare nut
147
4 MDV4+
VRF MIDEA
MIDEA | Unidade Internas
Unidades 5
Internas 6 7 8 Manual de Projeto 9
MI-140T1/DHN1-B, MI-160T1/DHN1-B
6. Esquema Elétrico
6.1 Unidades: MI-140T1/DHN1-BA, MI-160T1/DHN1-BA. 170
202085690112 TA T1 T2 T2B C.S XP4 XS4
OLD DISPLAY W IR E DC FAN
BOARD C ON T RO LL E R
WIRING DIAGRAM FAN1
(INDOOR UNIT) XP5 XS5
NEW DISPLAY W IR E
XP1 XS1
XP2 XS2
BOARD C ON T RO LL E R
CODE TITLE
WHITE BLACK
FAN1 DC FAN MOTOR
TA OUTLET AIR TEMP.
CN13
ROOM TEMP.
CN3
T1
T2 MIDDLE PIPE TEMP. C N2 3 C N2 4 CN 25 CN 26 CN 10 CN1 5 CN16
T2B OUTER PIPE TEMP.
C.S WATER LEVEL SWITCH DC motor
ELECTRONIC driver module
EEV.
EXPANSION VALVE
MAIN CONTROL BOARD CN29 BD-1 ~ -
RED
XP1-XP5 CONNECTOR + ~
CONNECTOR ON F 01 ON ON ON
XS1-XS5 RED(BLUE)
23
CDE
TERMINAL
4 56
XT1
AB
1 2 1 2 1 2
7 9
1 2 3 4 8
XT2 TERMINAL
SW6 ENC2 SW4 SW3 SW2 BLACK
XT3 TERMINAL CN30
PUMP PUMP MOTOR F 01 BROWN
23
CDE
7 9 BROWN
Y/G GND
8 CN58
ENC1
ENC1 Toggle For set
switch horsepower
Code Capacity CN20 CN8 CN18 CN27 CN28 CN19 CN50 CN1 CN2
0 2200W REACTOR
1 2800W
RED BLACK NOTE:
2 3600W
If no DC motor driver module,
BLACK
YELLOW
F 01
BLACK
WHITE
3 4500W Z1C
BLUE
GRAY
BLACK
ORANGE
N=1
WHITE
BLACK
GRAY
4 5600W
4 56
Y/G CN16.
AB
XP3 XS3
XT3
7 9
8 5 7100W XT1
ENC1 XT2
6 8000W Y/G
7 9000W PUMP
170
8 10000/11200W
12500/14000W
X- WHITE
9
A 16000W
Y- BLUE
EEV. ALARM COM ON/OFF
POWER INPUT (E)-BLACK
EEV.
NOTE: TO CCM COMM.BUS TO INDOOR COMM.BUS P- YELLOW
1.The functions in the dashed rectangle are Q- GRAY
available for particular Air-conditioner. NOTE:PLEASE USE 3-CORE SHIELDED WIRE
2.SW2-SW4,SW6 must be set as this diagram.
3.ENC2 is used for Static Pressure,must be SW3 Difinition Error code & indication
set according to the INSTALLATION MANUAL. SW6 Difinition
ON Timer LED and run LED flash No address when first time
l
SW3 00 means the time of stopping
l ON
together,or show "FE" power on
TERMAL fan is 4 mintues 1 means old display penal
l
1 2
1 2 3 4 0 means new display penal
l Defrost LED flash
l
J1J 2 Difin ition ON
SW6-1 or show "E0" Mode conflict
SW3 01 means the time of stopping
l
J1
TERMAL fan is 8 mintues
ON
Timer LED flash
l Communication error between
without jumper" J 1" for
l 1 2
1 means DC fan is chosen
l or sho w "E1" indoor and outdoor unit
auto restart function 1 2 3 4
0 means AC fan is chosen
l
ON SW6-2 Run LED flash
l Temp.sensor (T1) error(Split Duct Air Unit)
J1 SW3 10 means the time of stopping
l or show "E2" * Temp.sensor (TA) error(Fresh Air Unit)
with jumper"J1 " for
l 1 2 TERMAL fan is 12 mintues ON l1 means factory test mode
non-auto restart function l0 means auto addressing mode Run LED flash
l
Temp.sensor(T2)error
1 2 3 4
(default setting) or show "E3"
J2 ON SW6-3
SW3 11 means the time of stopping
l Run LED flash
l
reserved
l TERMAL fan is 16 mintues Temp.sensor(T2B)error
1 2 ON or show "E4"
1 2 3 4
reserved
l Timer LED flash slowly
l
DC FAN error
SW6-4 or show "E6"
SW2 Difinition SW4 Difinition
Defrost LED flash slowly
l
EEPROM error
or show "E7"
SW2
O
ONN
0 0 means shutting down the
l SW4
ON
00 means temp.compensation
l 0/1 Difinition
unit to" stop cold air" at 15℃ value is 6℃ under heat mode Alarm LED flash slowly
l
Outdoor unit error
or show "Ed"
1 2
1 2
ON
ON means0
l Alarm LED flash
l
SW2
ON
0 1 means shutting down the
l SW4 01 means temp.compensation
l Water level alarm
unit to" stop cold air" at 20℃ value is 2℃ under heat mode or show "EE"
1 2 1 2
本号:B,2012-2)
材 料 性 能 应 符 合QMZ-J53.011《 接 线 铭 牌 》 的 有 关 要
,其它印刷颜色如图纸标注(未注字体印刷颜色为黑
GB/T1804-v;
料应符合美的企业标准QMZ-J11.010《产品中限制使 ɼ
准》。 DESIGN
黎贵 整机型号
MODEL CE-MDV
ж
CO.BY 李运庆
名称
148 ¹Ò
卢国贵 PART
ÊÄ»½ÏÃÅ
PROESS
3 4 5 6 7 8
VRF
VRF MIDEA MDV4+
| Unidade Internas
Unidades Internas Manual de Projeto
XP8 XS8
XP6 XS6
XP7 XS7
WHITE BLACK
CN13
WHITE
CN3
BLACK
C N2 3 C N2 4 CN25 CN26 CN15 CN10 CN16
DC motor
driver module C N2 3 C N6 C N7 C N5 C N1 5 CN 10
MAIN CONTROL BOARD(A) CN29 RED BD-1 ~ -
A SYSTEM + ~ ON ON ON ON F 01
RED(BLUE) CN11
23
CDE
F 01 ON ON ON
ON
MAIN CONTROL BOARD(B)
4 56
23
CDE
AB
1 2 3
7 9
1 2 3 4 1 2 3 4 1 2 8
4 56
B SYSTEM
AB
1 2 3 4
7 9
8 1 2 1 2 1 2 BLACK SW1 SW2 SW5 SW6 ENC1
SW6 ENC2 SW4 SW3 SW2 CN30
F 01
BROWN
ON
23
CDE
BROWN
4 56
AB
Y/G GND
7 9 CN58
ENC1
8 1 2 CN1 TRANS
SW7
CN20 CN8 CN18 CN19 CN50 CN27 CN28 CN1 CN2 CN2 CN9 CN17 CN8 CN20
REACTOR
XP9 XS9
TA OUTLET AIR TEMP.
Y/G T1 ROOM TEMP.
PUMP
T2 MIDDLE PIPE TEMP.
T2B OUTER PIPE TEMP.
EEV. EEV. C.S WATER LEVEL SWITCH
EEV.(A) EEV.(B) EEV. ELECTRONIC
EXPANSION VALVE
XP1-XP9 CONNECTOR
YELLOW
YELLOW
For set
WHITE
WHITE
BLACK
BLACK
Toggle
BLACK
BLACK
ENC1
BLUE
BLUE
GRAY
GRAY
switch horsepower X- WHITE XS1-XS9 CONNECTOR
ORANGE
Y- BLUE
BLACK
XT1 TERMINAL
WHITE
BLACK
GRAY
Code Capacity
0 2200W
Z1C (E)-BLACK XT2,XT4 TERMINAL
N=1
1 2800W XT2 XT4 P- YELLOW XT3 TERMINAL
XT1
2 3600W Q- GRAY PUMP MOTOR
F 01 RED BLACK PUMP
3 4500W Y/G BRIDGE RECTIFIER
23
CDE
4 5600W
BD-1
4 56
AB
TRANS TRANSFORMER
7 9
8
ENC1
5 7100W
XT3 NOTE:
6 8000W
7 9000W
1.The functions in the dashed rectangle are
8 10000/11200W available for particular Air-conditioner.
9 12500/14000W TO CCM COMM. BUS TO OUTDOOR COMM. BUS TO CCM COMM. BUS TO OUTDOOR COMM. BUS 2.SW1-SW4,SW6-SW7 must be set as this diagram.
A 16000W ALARM COM ON/OFF NOTE:PLEASE USE
POWER INPUT
NOTE:PLEASE USE 3.ENC2 is used for Static Pressure,must be
3-CORE SHIELDED WIRE 3-CORE SHIELDED WIRE set according to the INSTALLATION MANUAL.
NOTE:(for factory)
1.For 200T1(8.0HP): Please dial switch ENC1 to
B for system A and 8 for B. FOR A SYSTEM: FOR B SYSTEM:
For 250T1(9.0HP): Please dial switch ENC1 to SW2 Difinition SW4 Difinition SW1 Difinition SW5 Difinition
C for system A and 9 for B. ON ON l1 means factory test mode ON
ON
For 280T1(10.0HP):Please dial switch ENC1to SW2 l0 0 means shutting down the SW4 00 means temp.compensation
l SW1
l0 means auto addressing mode
SW5 00 means temp.compensation
l
D for system A and 9 for B. 1 2 unit to" stop cold air" at 15℃ 1 2 value is 6℃ under heat mode 1 2 3 4 (default setting) 1 2 value is 6℃ under heat mode
IMPORTANCE:(for installation)
2. System A and system B must have SW2
ON
l0 1 means shutting down the SW4
ON
01 means temp.compensation
l SW1
ON
1 means DC fan is chosen
l SW5
ON
01 means temp.compensation
l
different unit address and need 1 2 unit to" stop cold air" at 20℃ 1 2
value is 2℃ under heat mode 1 2 3 4 0 means AC fan is chosen
l 1 2
value is 2℃ under heat mode
to be set different address alone.
3. System A and syetem B must have ON ON ON
different CCM net address and need SW2
ON
l10 means shutting down the SW4 10 means temp.compensation
l SW1 SW5 10 means temp.compensation
l
value is 4℃ under heat mode reserved
l value is 4℃ under heat mode
to be set different address alone. 1 2
unit to" stop cold air" at 24℃ 1 2 1 2 3 4 1 2
1 2 3 4
reserved
l
ON (default setting)
Timer LED flash slowly
l SW3 11 means the time of stopping
l SW6-3 SW2
ON
l11 means shutting down the 1 2 3
DC FAN error
or show "E6" 1 2 TERMAL fan is 16 mintues 1 2 3 4
unit to" stop cold air" at 26℃
ON
Defrost LED flash slowly
l
EEPROM error reserved
l SW7 Di finit ion
or show "E7" 1 2 3 4 ON
SW2 l00 means the time of stopping
SW6-4
Alarm LED flash slowly
l TERMAL fan is 4 mintues
Outdoor unit error J1 J2 D if ini tio n 1 2 3 4
SW7
ON
or show "Ed" standard configuration
l
J1 ON 1 2
* Show "H2"
Outdoor unit low tem-
perature protect
non-auto restart function
SYSTEM: 1 2 3 4 TERMAL fan is 12 mintues
J2 ON
Outdoor unit high tem- means1
* Show "H3" perature protect reserved
l l
SW2
ON
l11 means the time of stopping
1 2 3 4 TERMAL fan is 16 mintues
NOTE:The Error code with "*" is only used
for Fresh Air Handling Unit.
要求(版本号:B,2012-2)
观 质 量 、 材 料 性 能 应 符 合QMZ-J53.011《 接 线 铭 牌 》 的 有 关 要
为本色,其它印刷颜色如图纸标注(未注字体印刷颜色为黑
差应符合GB/T1804-v;
要求的物料应符合美的企业标准QMZ-J11.010《产品中限制使 ɼ
的技术标准》。 DESIGN
黎贵 整机型号
MODEL
ж
CO.BY 李运庆
¹Ò
名称
PROESS
卢国贵 PART
149
标准化 阶段标
STANDARD
吴田
VRF MIDEA
MIDEA MDV4+
| Unidade Internas
Unidades Internas Manual de Projeto
As capacidades de aquecimento e refrigeração são testados segundo a pressão estática padrão admissível;
A pressão estática de teste dos modelos 140/160 é 50Pa e a pressão estática de teste dos modelos 200/250/280 é de
62Pa.
• Se a pressão estática externa for muito alta, causada, por exemplo, por dutos muito extensos, a vazão de ar nas
saídas pode ser reduzida a níveis insuficientes, comprometendo a distribuição de ar e o atendimento da carga térmica
de projeto
• Existe um limite de vazão de ar mínima para cada velocidade Para cada limite, o ventilador atinge sua, respectiva,
máxima pressão estática e a unidade interna não corre risco de congelamento de serpentina.
• Existe o limite de vazão de ar máximo para cada velocidade. Isso requer que a unidade seja conectada ao duto tanto
pela entrada como saída de ar, para prevenir danos causados pela alta temperatura do motor/evaporador, se o calor
emitido não for corretamente dissipado
• Essas são as faixas que a unidade pode funcionar de formar estável . Para a faixa de pressão estática ideal, por
favor consulte o manual de instalação.
• Os riscos de selecionar uma unidade fora da faixa ideal incluem níveis de ruído mais altos, volume de fluxo de ar
baixo etc.
150
VRF
VRF MIDEA MDV4+
| Unidade Internas
Unidades Internas Manual de Projeto
8. Tabelas de Capacidade
8.1. Refrigeração
TC: capacidade total SC: capacidade sensível BU: Bulbo úmido BS: Bulbo seco
151
VRF MIDEA
MIDEA MDV4+
| Unidade Internas
Unidades Internas Manual de Projeto
152
VRF
VRF MIDEA MDV4+
| Unidade Internas
Unidades Internas Manual de Projeto
8.2 Aquecimento
TC: Capacidade total SC: Capacidade sensível BU: Bulbo úmido BS: Bulbo seco
153
VRF MIDEA
MIDEA MDV4+
| Unidade Internas
Unidades Internas Manual de Projeto
154
VRF
VRF MIDEA MDV4+
| Unidade Internas
Unidades Internas Manual de Projeto
9. Características Elétricas
Legenda:
MCA: Corrente mínima. (A)
MFA: Corrente máxima do fusível (A)
kW: Consumo nominal do motor do ventilador (kW)
FLA: Corrente a carga plena (A)
IFM: Motor do ventilador
Notas:
1. Faixa de tensão: As unidades são configuradas para o uso em sistemas elétricos onde a tensão nos terminais da
unidade não estão nem acima e nem abaixo dos limites.
2. O desequilíbrio de tensão máximo admissível entre as fases é de 2%.
3. MCA = 1.25 × FLA
4. Selecione o diâmetro de fio com base no MCA.
5. Ao invés de fusível, use um disjuntor.
2m 1m
1.4m
Microfone
*Valores medidos em câmara anecóica.
155
VRF MIDEA
MIDEA MDV4+
| Unidade Internas
Unidades Internas Manual de Projeto
MI-160T1/DHN1-BA
156
VRF
VRF MIDEA MDV4+
| Unidade Internas
Unidades Internas Manual de Projeto
11. Acessórios
11.1. Acessórios básicos
Manual de Instalação 1 / /
7.1~16kW 2
Material para isolamento
Isolamento térmico
de tubos
20~28kW 4
7.1~16kW 1
Utilizada para a ligação de tubos de
Porca de cobre
instalação de engenharia
20~28kW 2
Conector válvula de
20~28kW 1 Conector elétrico A
expansão A
Conector válvula de
20~28kW 1 Conector elétrico B
expansão B
157
Manual de Projeto
Unidades Externas VRF
MDV4+ Mini
100% INVERTER
ÍNDICE
INFORMAÇÕES & CARACTERÍSTICAS
1. nomenclatura ............................................................................................................... .......................... 5
2. Organização do produto ......................................................................................................................... 6
3. Características ........................................................................................................................................ 7
4. Instalação e Manutenção mais conveniente ........................................................................................ 10
5. Capacidades das Unidades Internas .................................................................................................... 12
6. Aparência Externa e nomes dos modelos das Unidades Internas ....................................................... 13
PROCEDIMENTO DE INSTALAÇÃO
1. Resumo da instalação .......................................................................................................................... 29
2. Instalação das unidades externas ........................................................................................................ 30
3. Instalação da tubulação de refrigerante ............................................................................................... 34
4. Processamento e instalação do tubo de drenagem ............................................................................. 39
5. Obras de isolação ................................................................................................................................. 43
6. Instalação elétrica ................................................................................................................................. 46
7. Execução de testes .............................................................................................................................. 50
8. Precauções em termos de vazamento de refrigerante ........................................................................ 51
TROUBLESHOOTING
1. Fenômenos normais no sistema de ar-condicionado ........................................................................... 52
2. Proteção do ar-condicionado ................................................................................................................ 53
3. Códigos e diagnóstico de falhas ........................................................................................................... 54
SISTEMA ELÉTRICO
1. Sistema Elétrico ................................................................................................................................... 72
VRF MIdEA MdV4+ MInI Manual de Projeto
1. Nomenclatura
M D V - V 120 W / D
.V.N1
..
Refrigerante
n1:R410A
Fonte de alimentação
V: 208~230V-60 Hz, monofásica
C: 380~415V, 60 Hz, trifásica
Tipo do inversor
d: Inversor CC
Inverter
Midea VRF
5
VRF MIdEA MdV4+ MInI Manual de Projeto
2. Organização do produto
Modelo dimensões (mm) LXAXP Peso líquido/ bruto (kg) Fonte de alimentação
MdV-V105W/dnV1 990x966x396 78/85 208-230V1ph~60Hz
MdV-V160W/dVn1 102/113
MdV-V120W/dCn1 95/106
MdV-V160W/dCn1 102/113
6
VRF MIdEA MdV4+ MInI Manual de Projeto
3. Características
A Midea oferece uma variedade de unidades internas com mais de 100 modelos de 15 tipos. As faixas de capacidades
vão de 1,8 kW (0,6 HP) a 16 kW (7 HP). Elas são totalmente compatíveis com domicílios residenciais e pontos comerciais
de pequeno porte. nossos sistemas podem operar em até 130% da capacidade, permitindo o projeto de qualquer sistema
para atender às necessidades dos clientes e das aplicações.
7
VRF MIdEA MdV4+ MInI Manual de Projeto
Estrutura compacta
Como a relação de carga dos condicionadores de ar em construções é de 30 a 75%, a utilização de área é de 55% e
a maioria dos condicionadores de ar opera em carga parcial, o funcionamento em carga média controla a carga anual.
Enrolamento Enrolamento
centralizado distribuído
8
VRF MIdEA MdV4+ MInI Manual de Projeto
Sensor de pressão
Motor do ventilador CC
Pressão alta
A velocidade do rotor do motor varia em torno de ±5r pode igualar rapidamente a saída do Compressor do Inversor CC,
além de melhorar o rendimento em carga parcial.
O design diferenciado dos ventiladores e das grelhas de ar proporciona baixíssimos níveis de ruído.
defletor de ar
9
VRF MIdEA MdV4+ MInI Manual de Projeto
l
Frontal Latera
Parte traseira
Parte de baixo
Fácil instalação
O tubo de derivação e as quatro caixas de conexão diferentes estão disponíveis para o sistema de Mini VRF 100 %
Inverter. Eles podem ser escolhidos de acordo com as diferentes solicitações de projeto.
Endereçamento automático
O endereçamento das unidades externas e internas é efetuado automaticamente pelo simples acionamento do botão
do controlador.
• A unidade externa pode distribuir automaticamente o endereço às unidades internas sem nenhuma configuração manual.
• O controlador sem fio pode consultar e modificar o endereço de cada unidade interna.
Modelo
Configuração anterior Auto-identif.
manual de cada por controle
unidade V4 PLUS remoto
Aprimorado
10
VRF MIdEA MdV4+ MInI Manual de Projeto
É possível habilitar o uso compartilhado da fiação entre as unidades internas e externas, bem como o controle centralizado.
Conecte o amperímetro e CCM02 e nIM06 no Mini VRF para efetuar o cálculo de consumo de energia.
11
VRF MIdEA MdV4+ MInI Manual de Projeto
1. Especificações
Modelos 220V
Modelo MDV -V105W/D VN1 MDV -V120W/D VN1 MDV -V140W/D VN1 MDV -V160W/D VN1
Alimentação V-Ph-Hz 208-230V-1Ph~6 0Hz
15
VRF MIdEA MdV4+ MInI Manual de Projeto
Modelo MDV -V105W/D VN1 MDV -V120W/D VN1 MDV -V140W/D VN1 MDV -V160W/D VN1
nível sonoro de saída (nível de pressão
57
sonora) dB(A)
dimensões (L x A x P) 990x966x396 900x1327x320
Unidade mm
externa Embalagem (L x A x P) (1030x1456x435)
mm 1120x1100x435
Peso líquido/bruto kg 78/85 209.4/233.7 ( 95/106 ) 224.9/249.1(102/113)
Tipo R410A
Refrigerante
Volume carregado kg 3.0 3.3 3.9 3.9
diferença máximo no 8 8
m 8 8
nível
Fiação de força 2 3 condutores x 4,0
Fiação de mm
conexão Fiação de sinalização 2 Fiação isolada com 3 núcleos.diâmetro 0,50
mm
Temperatura ambiente (°C) Refrigeração -15~48°C Aquecimento -15~27°C
Notas:
1. Condições de refrigeração: temp. interna: 27°C BS(80,6°F), 19°C BU(60°F) temp. externa: 35°BS(95°F) comprimento
de tubo equivalente: 5 m comprimento de queda: 0 m.
2. Condições de aquecimento: temp. interna.: 20°C BS(68°F), 15°C BU(44,6F) temp. externa: 7°C BS(42,8°F) comprimento
de tubo equivalente: 5 m comprimento de queda: 0 m.
3. nível sonoro: Valor de conversão da câmara anecóica, medido em um ponto a 1,0 m na frente da unidade em uma
altura de 1,0 m. durante a operação real, esses valores serão normalmente um pouco mais altos como resultado das
condições ambientes.
4. Os dados acima poderão ser alterados sem aviso prévio para futuras melhorias em termos de qualidade e desempenho.
16
VRF MIdEA MdV4+ MInI Manual de Projeto
Modelos 380V
17
VRF MIdEA MdV4+ MInI Manual de Projeto
Pressão de
4.4/2.6 4.4/2.6
projeto MPa 4.4/2.6
Lado do líquido Ɏ3/8( Ɏ9.52 ) Ɏ3/8( Ɏ9.52 )
in.(mm ) Ɏ3/8( Ɏ9.52 )
Lado do gás Ɏ5/8( Ɏ15.9) Ɏ3/4(Ɏ19.1 )
Tubulação in.(mm ) Ɏ5/8( Ɏ15.9)
de Comprimento máximo da
refrigerante tubulação de refrigerante 100 100 100
m
diferença máximo no
m 8 8 8
nível
Fiação de força 2 5 condutores x 2,5
Fiação de mm
conexão Fiação de sinalização 2 Fio isolado com 3 núcleos. diâmetro
mm
Temperatura ambiente (°C) Refrigeração -15~48°C Aquecimento -15~27°C
Notas:
1. Condições de refrigeração: temp. interna: 27°C BS(80,6°F), 19°C BU(60°F) temp. externa: 35°C BS(95°F) comprimento
de tubo equivalente: 5 m comprimento de queda: 0 m.
2. Condições de aquecimento: temp. interna.: 20°C BS(68°F), 15°CBU(44,6F) temp. externa: 7°C BS(42,8°F) comprimento
de tubo equivalente: 5 m comprimento de queda: 0 m.
3. nível sonoro: Valor de conversão da câmara anecóica, medido em um ponto a 1,0 m na frente da unidade em uma
altura de 1,0 m. durante a operação real, esses valores serão normalmente um pouco mais altos como resultado das
condições ambientes.
4. Os dados acima poderão ser alterados sem aviso prévio para futuras melhorias em termos de qualidade e desempenho.
18
VRF MIdEA MdV4+ MInI Manual de Projeto
2. Dimensões
Unidade: in.(mm)
19