Você está na página 1de 20

LAPORAN PRAKTIKUM

MESIN-MESIN LISTRIK
SLIP-RING INDUCTION MOTOR 1

DISUSUN OLEH
DIKI RIANDY
2105031045
EL-5A

PRODI TEKNIK LISTRIK


JURUSAN TEKNIK ELEKTRO
POLITEKNIK NEGERI MEDAN
TAHUN AJARAN 2023/2024
LEMBAR PENILAIAN

Judul Praktikum : SLIP-RING INDUCTION MOTOR 1


Nomor Jobsheet :8
Nama Praktikan : Diki Riandy
kelas : EL-5A
NIM : 2105031045
Nama Kelompok : 1. Ajeng Ardyanti Syahputri
2. Calvin Winata
3. Deny Ahmad Fadilla
4. Desika
5. Diki Riandy
6. Dito H. Sigalingging
Kelompok : A1
Nama Instruktur : 1. Darwis Tampubolon, ST., MT.
2. Suprianto, ST., MT.
Tanggal Praktikum : 29 November 2023
Tanggal Kumpul Laporan : 6 Desember 2023
Nilai :

i
DAFTAR ISI

LEMBAR PENILAIAN ......................................................................................................... i


DAFTAR ISI ........................................................................................................................ ii
SLIP-RING INDUCTION MOTOR 1 ................................................................................... 3
A. Equipment .................................................................................................................. 3
B. Procedure ................................................................................................................... 4
C. Problems and exercises ............................................................................................... 5
D. Tables ......................................................................................................................... 6

ii
PRAKTIKUM MESIN-MESIN LISTRIK
SLIP-RING INDUCTION MOTOR 1

K L M
rpm

U2 V2 W2 I2
F2 A2
A A
K
L
G TG M
M

F1 A1

U1 V1 W1

U1 V1 W1
Y
R S T

U V W
Z
R S T

V P

I
RB
V
I1

L1 L2 L3
220 V = 3 x 0-230 V
F MV 1300 F MV 1300

A. Equipment

G = Electric torque meter MV 1036


M = Induction motor MV 1007
TG = Tachometer generator MV 1025
𝑅𝐵 = Load resisitor MV1100
R = Rotor starter MV 1013(or MV 2636)
V = Voltmeter 500 V MV 1926
𝐼1 = Ammeter 6 A MV 1923
𝐼2 = Ammeter 20-0-20 A MV 1924
𝑃 = Wattmeter 1 A MV 1927

3
𝑇 = Current transformer 10/1 A MV 1931
Y = Star-delta switch MV 1503
Z = Reversing stanter MV 1502
S = Switch MV 1500
F = Power Pack MV 1300

B. Procedure
a) Connecting up

1. Connect the torque meter as generator and the induction motor as motor as shown
in figure 6-3. Switch S must be off and the other two switches is position “Forwad”
and “∆”.
2. Make a node of the ratings of the induction motor shown on the rating plate.
3. The supervisor should now check all connections before switching on power.

b) Measurement of starting current

1. Set the rotor Starter to minimum resistance and switch on the AC Voltage. Hold
the rotor (use protection gloves) with the hand and turn up the voltage to 50V.
Make a note of current. Turndown the voltage to zero.
2. Set the rotor starter to maximum resistance. Hold the rotor with the hand an turn
up the voltage to 50V. Make a note of the current 𝐼𝑎 . Turn down the voltage to
zero.
3. Set the rotor starter to minimum resistance and the star/delta-switch to Y. Hold the
rotor with the hand and turn up voltage to 50V. Make a note of the current. Turn
down the voltage and turn off the voltage switch.

c) Plugging

1. Set the rotor starter to maximum resistance,star/delta-switch to Y and the reversing


starter to 0. Switch on the AC voltage and turn it up to 230 V
2. Turn the reversing starter to Forward and the motor starts.When the motor has
reached full speed,turn the star/delta-swtich to ∆
3. Switch to back star connection,Switch the reversing starter to Reverse and measure
the time before the motor stops,Swtich off the AC voltage

d) Measurment of efficiency and torque characteristics

1. Set the rotor starter to maximum resistance, star/delta-switch to “∆” and the
reversing satarter to forwad. Switch on the AC voltage, the motors starts. Slowly
turn off the rotor starter.
2. Adjust the voltage V to 230 V and keep it constant during the measurements. Read
V, 𝐼1 , P,T, 𝑛2 , and the rotor frequency on the ammeter 𝐼2 . Check that the load
resistor 𝑅𝑠 is set to minimum current. Turn on switch S and the DC voltage.

4
3. Vary the load with the shunt rheostat of thetorque meter and the load resistor 𝑅𝑆 in
steps of 1 Nm up to 7.5 Nm. For each step,make a note of V, 𝐼1 P, T, 𝑛2 and 𝑓2 .
4. Adjust the load resistor to minimum current. Turn off switch S.

e) Speed control

1. Adjust the rotor starter so that roughlty half of its resitance is connected to the rotor
circuit. When using starter MV 2636, set the switch to R2.
2. Repeat measurments A to D.
3. Switch off the 220v DC and 230/133V AC.

C. Problems and exercises

1. Fill in “Calculated values” in the table.


2. Draw the graphs ŋ = f(P out) for measurments D and E.
3. Draw the graph T = f(S) for measurments D and E. Extrapolate the graph to T = 0.
What is the slip when T = 0? Explain the difference.
4. Calculate the percentage of no-load current in relation to the rated current.
5. Calculated the power factor at full load. Explainn the low Value.
6. Draw the circuit diagram for star/delata and reversing started and describe the
fuctions of the switches.
7. Calculated the starting current ratio between delta and star connection. What is the
theoretical value?.

5
D. Tables
Rated power = 1,5 KW
Rated speed = 1440 rpm

Rotor stator pada posisi full.


Means Measured values
no
V (v) Im 𝐼𝑅 (A) P (w) T N S (%)
(A) (Nm) (rpm)
230 6,10 0,14 952 1 1450 0,033
230 6,16 0,14 1020 2 1450 0,033
230 6,03 0,14 1116 3 1450 0,033
230 6,48 0,14 1028 4 1450 0,033
D
230 6,63 0,14 1295 5 1450 0,033
230 6,87 0,14 1386 6 1450 0,033
230 7,1 0,14 1470 7 1450 0,033
230 7,21 0,14 1512 7,5 1450 0,033

Rotor stator pada posisi ½.


Means Measured values
no
V (v) Im (A) 𝐼𝑅 (A) P (w) T (Nm) N (rpm) S(%)
230 6 0,08 928 1 1400 0,067
230 6,12 0,23 1009 2 1350 0,1
230 6,19 0,70 1090 3 1280 0,147
230 6,38 1,1 1185 4 1240 0,173
E
230 6,52 1,46 1264 5 1180 0,213
230 6,81 1,81 1370 6 1120 0,253
230 7,04 2,21 1455 7 1050 0,3
230 7,16 2,3 1505 7,5 1020 0,32

6
E. Analisis

Hasil perhitungan 6.4.4


(rotor stator pada kondisi full)

1. 𝑃𝑜𝑢𝑡 = 952 W

𝑃𝑖𝑛 = √3 𝑥 𝑉𝑥 𝐼 𝑥 cos 𝜃
= √3 𝑥 230 𝑥 6,10 𝑥 0,85
= 2065,56 W

𝑃𝑜𝑢𝑡
%𝑛 = 𝑥 100%
𝑃𝑖𝑛
952
= 2065,56 𝑥 100%
= 0,461

50
𝑁𝑠 = 120 𝑥 4
= 1500

𝑁𝑠−𝑁
%𝑆 = 𝑥 100%
𝑁𝑠
1500 − 1450
= 𝑥 100%
1500

= 0,033

2. 𝑃𝑜𝑢𝑡 = 1020 W

𝑃𝑖𝑛 = √3 𝑥 𝑉𝑥 𝐼 𝑥 cos 𝜃
= √3 𝑥 230 𝑥 6,16 𝑥 0,85
= 2085,87 W

𝑃𝑜𝑢𝑡
%𝑛 = 𝑥 100%
𝑃𝑖𝑛
1020
= 𝑥 100%
2085,87
= 0,489

50
𝑁𝑠 = 120 𝑥 4
= 1500

𝑁𝑠−𝑁
%𝑆 = 𝑥 100%
𝑁𝑠
1500 − 1450
= 𝑥 100%
1500

7
= 0,033

3. 𝑃𝑜𝑢𝑡 = 1116 W

𝑃𝑖𝑛 = √3 𝑥 𝑉𝑥 𝐼 𝑥 cos 𝜃
= √3 𝑥 230 𝑥 6,03 𝑥 0,85
= 2041,85 W

𝑃𝑜𝑢𝑡
%𝑛 = 𝑥 100%
𝑃𝑖𝑛
1116
= 2041,85 𝑥 100%
= 0,546

50
𝑁𝑠 = 120 𝑥 4
= 1500

𝑁𝑠−𝑁
%𝑆 = 𝑥 100%
𝑁𝑠
1500 − 1450
= 𝑥 100%
1500

= 0,033

4. 𝑃𝑜𝑢𝑡 = 1028 W

𝑃𝑖𝑛 = √3 𝑥 𝑉𝑥 𝐼 𝑥 cos 𝜃
= √3 𝑥 230 𝑥 6,48 𝑥 0,85
= 2194,23 W

𝑃𝑜𝑢𝑡
%𝑛 = 𝑥 100%
𝑃𝑖𝑛
1028
= 2194,23 𝑥 100%
= 0,468

50
𝑁𝑠 = 120 𝑥 4
= 1500

𝑁𝑠−𝑁
%𝑆 = 𝑁𝑠
𝑥 100%
1500 − 1450
= 𝑥 100%
1500

8
= 0,033

5. 𝑃𝑜𝑢𝑡 = 1386 W

𝑃𝑖𝑛 = √3 𝑥 𝑉𝑥 𝐼 𝑥 cos 𝜃
= √3 𝑥 230 𝑥 6,87 𝑥 0,85
= 2326,29 W

𝑃𝑜𝑢𝑡
%𝑛 = 𝑥 100%
𝑃𝑖𝑛
1386
= 2326,29 𝑥 100%
= 0,596

50
𝑁𝑠 = 120 𝑥 4
= 1500

𝑁𝑠−𝑁
%𝑆 = 𝑥 100%
𝑁𝑠
1500 − 1450
= 𝑥 100%
1500

= 0,033

6. 𝑃𝑜𝑢𝑡 = 1386 W

𝑃𝑖𝑛 = √3 𝑥 𝑉𝑥 𝐼 𝑥 cos 𝜃
= √3 𝑥 230 𝑥 6,87 𝑥 0,85
= 2528,58 W

𝑃𝑜𝑢𝑡
%𝑛 = 𝑥 100%
𝑃𝑖𝑛
1386
= 2528,58 𝑥 100%
= 0,548

50
𝑁𝑠 = 120 𝑥 4
= 1500

𝑁𝑠−𝑁
%𝑆 = 𝑥 100%
𝑁𝑠
1500 − 1450
= 1500
𝑥 100%

= 0,033

9
7. 𝑃𝑜𝑢𝑡 = 1470 W

𝑃𝑖𝑛 = √3 𝑥 𝑉𝑥 𝐼 𝑥 cos 𝜃
= √3 𝑥 230 𝑥 7,1 𝑥 0,85
= 2404,17 W

𝑃𝑜𝑢𝑡
%𝑛 = 𝑥 100%
𝑃𝑖𝑛
1470
= 2404,17 𝑥 100%
= 0,611

50
𝑁𝑠 = 120 𝑥 4
= 1500

𝑁𝑠−𝑁
%𝑆 = 𝑥 100%
𝑁𝑠
1500 − 1450
= 𝑥 100%
1500

= 0,033

8. 𝑃𝑜𝑢𝑡 = 1512 W

𝑃𝑖𝑛 = √3 𝑥 𝑉𝑥 𝐼 𝑥 cos 𝜃
= √3 𝑥 230 𝑥 7,21 𝑥 0,85
= 2441,42 W

𝑃𝑜𝑢𝑡
%𝑛 = 𝑥 100%
𝑃𝑖𝑛
1512
= 2441,42 𝑥 100%
= 0,619

50
𝑁𝑠 = 120 𝑥 4
= 1500

𝑁𝑠−𝑁
%𝑆 = 𝑥 100%
𝑁𝑠
1500 − 1450
= 1500
𝑥 100%

= 0,033

10
Hasil perhitungan 6.4.5
(rotor stator pada kondisi 1⁄2)

1. 𝑃𝑜𝑢𝑡 = 928 W

𝑃𝑖𝑛 = √3 𝑥 𝑉𝑥 𝐼 𝑥 cos 𝜃
= √3 𝑥 230 𝑥 6 𝑥 0,85
= 2031,69 W

𝑃𝑜𝑢𝑡
%𝑛 = 𝑥 100%
𝑃𝑖𝑛
928
= 2031,69 𝑥 100%
= 0,457

50
𝑁𝑠 = 120 𝑥 4
= 1500

𝑁𝑠−𝑁
%𝑆 = 𝑥 100%
𝑁𝑠
1500 − 1400
= 𝑥 100%
1500

= 0,067

2. 𝑃𝑜𝑢𝑡 = 1009 W

𝑃𝑖𝑛 = √3 𝑥 𝑉𝑥 𝐼 𝑥 cos 𝜃
= √3 𝑥 230 𝑥 6,12 𝑥 0,85
= 2072,33 W

𝑃𝑜𝑢𝑡
%𝑛 = 𝑥 100%
𝑃𝑖𝑛
1009
= 2072,33 𝑥 100%
= 0,487

50
𝑁𝑠 = 120 𝑥 4
= 1500

𝑁𝑠−𝑁
%𝑆 = 𝑥 100%
𝑁𝑠
1500 − 1350
= 𝑥 100%
1500

= 0,1

11
3. 𝑃𝑜𝑢𝑡 = 1090 W

𝑃𝑖𝑛 = √3 𝑥 𝑉𝑥 𝐼 𝑥 cos 𝜃
= √3 𝑥 230 𝑥 6,19 𝑥 0,85
= 2096.03 W

𝑃𝑜𝑢𝑡
%𝑛 = 𝑥 100%
𝑃𝑖𝑛
1090
= 2096.03 𝑥 100%
= 0,52

50
𝑁𝑠 = 120 𝑥 4
= 1500

𝑁𝑠−𝑁
%𝑆 = 𝑥 100%
𝑁𝑠
1500 − 1280
= 𝑥 100%
1500

= 0,147

4. 𝑃𝑜𝑢𝑡 = 1185 W

𝑃𝑖𝑛 = √3 𝑥 𝑉𝑥 𝐼 𝑥 cos 𝜃
= √3 𝑥 230 𝑥 6,38 𝑥 0,85
= 2160,37 W

𝑃𝑜𝑢𝑡
%𝑛 = 𝑥 100%
𝑃𝑖𝑛
1185
= 2160,37 𝑥 100%
= 0,55

50
𝑁𝑠 = 120 𝑥 4
= 1500

𝑁𝑠−𝑁
%𝑆 = 𝑥 100%
𝑁𝑠
1500 − 1240
= 1500
𝑥 100%

= 0,173

12
5. 𝑃𝑜𝑢𝑡 = 1264 W

𝑃𝑖𝑛 = √3 𝑥 𝑉𝑥 𝐼 𝑥 cos 𝜃
= √3 𝑥 230 𝑥 6,52 𝑥 0,85
= 2207,77 W

𝑃𝑜𝑢𝑡
%𝑛 = 𝑥 100%
𝑃𝑖𝑛
1264
= 2207,77 𝑥 100%
= 0,57

50
𝑁𝑠 = 120 𝑥 4
= 1500

𝑁𝑠−𝑁
%𝑆 = 𝑁𝑠
𝑥 100%
1500 − 1180
= 𝑥 100%
1500

= 0,213

6. 𝑃𝑜𝑢𝑡 = 1370 W

𝑃𝑖𝑛 = √3 𝑥 𝑉𝑥 𝐼 𝑥 cos 𝜃
= √3 𝑥 230 𝑥 6,81 𝑥 0,85
= 2305,97 W

𝑃𝑜𝑢𝑡
%𝑛 = 𝑥 100%
𝑃𝑖𝑛
1370
= 2305,97 𝑥 100%
= 0,59

50
𝑁𝑠 = 120 𝑥 4
= 1500

𝑁𝑠−𝑁
%𝑆 = 𝑥 100%
𝑁𝑠
1500 − 1120
= 𝑥 100%
1500

= 0,253

13
7. 𝑃𝑜𝑢𝑡 = 1455 W

𝑃𝑖𝑛 = √3 𝑥 𝑉𝑥 𝐼 𝑥 cos 𝜃
= √3 𝑥 230 𝑥 7,04 𝑥 0,85
= 2383,86 W

𝑃𝑜𝑢𝑡
%𝑛 = 𝑥 100%
𝑃𝑖𝑛
1455
= 2383,86 𝑥 100%
= 0,61

50
𝑁𝑠 = 120 𝑥 4
= 1500

𝑁𝑠−𝑁
%𝑆 = 𝑁𝑠
𝑥 100%
1500 − 1050
= 𝑥 100%
1500

= 0,3

8. 𝑃𝑜𝑢𝑡 = 1505 W

𝑃𝑖𝑛 = √3 𝑥 𝑉𝑥 𝐼 𝑥 cos 𝜃
= √3 𝑥 230 𝑥 7,16 𝑥 0,85
= 2424,49 W

𝑃𝑜𝑢𝑡
%𝑛 = 𝑥 100%
𝑃𝑖𝑛
1505
= 𝑥 100%
2424,49
= 0,62

50
𝑁𝑠 = 120 𝑥 4
= 1500

𝑁𝑠−𝑁
%𝑆 = 𝑥 100%
𝑁𝑠
1500 − 1020
= 𝑥 100%
1500

= 0,32

14
F. Jawaban
1. Sudah ada pada bagian analisis di halaman sebelumnya.

2. Diketahui pada tabel 6.4.4 dan tabel 6.4.5 adalah sebagai berikut.
Pout η = f.(Pout) Pout η = f.(Pout)
No f Tabel 6.4.4 Tabel 6.4.5
1 50 952 47600 928 46400

2 50 1020 51000 1009 50450

3 50 1116 55800 1090 54500

4 50 1028 51400 1185 59250

5 50 1295 64750 1264 63200

6 50 1386 69300 1370 68500


7 50 1470 73500 1455 72750

8 50 1512 75600 1505 75250

Jadi, Grafik nilai efisiensi η adalah sebagai berikut:

Grafik nilai efisiensi η


160000

140000

120000

100000

80000

60000

40000

20000

0
1 2 3 4 5 6 7 8 9

η = f.(Pout) η = f.(Pout)

15
3. Gambar grafik nilai torsi pada tabel percobaan 6.4.4 dan 6.4.5

grafik torsi
0.35

0.3

0.25

0.2
S(%)

0.15

0.1

0.05

0
0 1 2 3 4 5 6 7 8

T ( Nm )
S ( % ) TABEL 6.4.5 S (%) TABEL 6.4.4

4. Presentasenya strating current tanpa beban


 Hubungan delta
1) Minimal rotor stater :
1,55 A
IM = 𝑥100% = 38,75 %
4𝐴
2) Maksimal rotor stater :
7,9 A
IM = 𝑥100% = 197,5%
4𝐴
 Hubungan star
1) Minimal rotor stater :
0,52 A
IM = 𝑥100% = 13%
4A

5. Sesuai dengan hasil percobaan


V = 230 V
𝐼𝑚 = 7,21 A
𝑃 = 1512 W
𝑃
Maka, cos 𝜑 = 𝑉𝑋𝐼
1512
cos 𝜑 = 230 𝑥 7,21
cos 𝜑 = 0,91

16
6. Gambar diagram rangkaian start delta dan revesing starter
 Diagram rangkaian Start Delta

 Gambar start pembalik ( revesing starter)

Keterangan gambar:

17
 gambar A: Saya sudah menambahkan thermal overload dan 2 kontaktor dalam
rangkaian, yaitu K1 dan K2. Dalam gambar A ini K1 dalam posisi NC atau
sedang dalam kondisi ON, dan K2 dalam posisi Off. Lihatlah bagaimana urutan
phasa input R-S-T masuk dalam rangkaian, sehingga putaran motor menjadi
kearah kanan.
 gambar B: Dalam gambar B ini urutan phasa input yang masuk dalam rangkaian
adalah kebalikannya, yaitu T-S-R bila K2 dalam posisi NC atau ON, dan K1
dalam posisi Off. Dan membuat arah putaran motor menjadi kearah kiri.
 Fungsi dari saklar tersebut ialah Untuk membalik arah putaran motor star delta
sebenarnya sama saja dengan membalik putaran motor induksi 3 fasa yang
beroperasi dalam koneksi delta ataupun motor induksi 3 fasa yang beroperasi
dalam koneksi star, yaitu dengan membalik salah satu tegangan yang masuk ke
motor. Namun dalam metode start star delta, motor 3 fasa tersebut dioperasikan
dalam kedua koneksi yaitu koneksi star pada mula startnya dan setelah itu
berganti dengan koneksi delta. karena hal itu akan ada 6 terminal pada motor
yang didesain untuk metode start star delta.

7. Starting current
 Hubungan delta
3) Minimal rotor stater :
IM = 1,55 A
IR = 0,66 A
4) Maksimal rotor stater :
IM = 7,9 A
IR = 4,6 A
 Hubungan star
2) Minimal rotor stater :
IM = 0, ,52 A
IR = 0,39 A

18
G. Kesimpulan
1. Motor induksi 3 fasa rotor lilit adalah motor induksi yang lilitan rotor disambung
di luar motor. Sedangkan motor induksi 3 fas rotor sangkar adalah motor induksi
yang lilitan rotornya disambungkan di dalam bodi motor.
2. Motor rotor lilit, juga dikenal sebagai motor rotor cincin slip adalah jenis motor
induksi yang belitan rotornya terhubung melalui cincin slip ke tantangan luar.
3. Motor rotor sangkar memiliki putaran yang lebih tinggi dibandingkan motor

induksi rotor lilit. Dengan putaran yang lebih tinggi, berarti motor sangkar
memiliki torsi yang lebih rendah dibandingkan motor lilit.
4. Karakteristik kecepatan dan torsi motor rotor lilit dapat ditur dengan mengubah
hambatan luar, tidak seperti motor sangkar yang mempunyai karakteristik tetap.
5. Motor slip ring atu sering disebut motor rotor lilit termasuk motor induksi 3 phasa
dengan rotor belitan dan dilengkapi dengn slip ring yang dihubungkan dengan sikat
arang ke terminal. Motor slip ring dirancang untuk daya besar.

Medan, 06 Desember 2023

Diki Riandy
2105031045

19