Você está na página 1de 2

Totally Integrated

Automation Portal

Trabalho_15_02_2023 / PLC_1 [CPU 314C-2 PN/DP] / Program blocks


LADER [FB1]
LADER Properties
General
Name LADER Number 1 Type FB Language LAD
Numbering automatic
Information
Title Author Comment Family
Version 0.1 User-defined
ID

LADER
Name Data type Offset Default value Accessible Visible in Setpoint Comment
from HMI HMI
Input
Output
InOut
Static
Temp
Constant

Network 1:

%I136.0 %I136.1 %Q136.1 %Q136.0


"LigaLD" "DesligaLD" "Motor2LD" "Motor1LD"

%Q136.0
"Motor1LD"

%M3.0
"Reinicia_
processo"

Symbol Address Type Comment


"DesligaLD" %I136.1 Bool
"LigaLD" %I136.0 Bool
"Motor1LD" %Q136.0 Bool
"Motor2LD" %Q136.1 Bool
"Reinicia_processo" %M3.0 Bool

Network 2:

%DB1
"T01"
%Q136.0 TON
"Motor1LD" Time
IN Q
T#3S PT ET ...

Symbol Address Type Comment


"Motor1LD" %Q136.0 Bool

Network 3:

%M3.0
%DB1.DBX6.0 %I136.1 "Reinicia_ %Q136.1
"T01".Q "DesligaLD" processo" "Motor2LD"

%Q136.1
"Motor2LD"

Symbol Address Type Comment


"DesligaLD" %I136.1 Bool
"Motor2LD" %Q136.1 Bool
"Reinicia_processo" %M3.0 Bool
"T01".Q %DB1.DBX6.0 Bool

Network 4:
Totally Integrated
Automation Portal

%DB2
"T02"
%Q136.1 TON
"Motor2LD" Time
IN Q
T#5S PT ET ...

Symbol Address Type Comment


"Motor2LD" %Q136.1 Bool

Network 5:

%M3.1 %M3.0
%DB2.DBX6.0 "MemoriaDesliga "Reinicia_
"T02".Q M2" processo"

%M3.0
"Reinicia_
processo"

Symbol Address Type Comment


"MemoriaDesligaM2" %M3.1 Bool
"Reinicia_processo" %M3.0 Bool
"T02".Q %DB2.DBX6.0 Bool

Network 6:

%M3.0 %M3.1
"Reinicia_ %Q136.0 "MemoriaDesliga
processo" "Motor1LD" M2"

Symbol Address Type Comment


"MemoriaDesligaM2" %M3.1 Bool
"Motor1LD" %Q136.0 Bool
"Reinicia_processo" %M3.0 Bool