SIKORSKY S-76C+
SISTEMA ELTRICO
PRINCIPAL SECUNDRIO
CORRENTE CONTNUA CORRENTE ALTERNADA
DC DC EXT
POWER
ESS BUS
EXT POWER
CONTACTOR
BUS-TIE
DC ESS BUS
RECOVERY
CONTACTOR
No. 1 CONTACTOR
START No.1 GEN No.1 DC PRIMARY
GEN CONTACTOR BUS
No.2 AC
PRIMARY BUS
INV BUS
No. 2 INVERTER
CONTACTOR
No. 2 26-VAC AC
BUS GEN
TRANSFORMER
AC GEN
AC
CONTACTOR
INV
CONTACTOR
AC MONITOR
BUS
No. 1 AC
PRIMARY BUS
INV BUS No.1
CONTACTOR INVERTER
No.1 26-VAC BUS TRANSFORMER
LOCALIZAO DOS COMPONENTES DC
CONTROLES E INDICADORES
PAINEL DE DISJUNTORES
SUPERIOR INFERIOR
BARRAS PRIMRIAS DC BARRAS ESSENCIAL e115 AC
TETO
BARRAS
26 VAC
BATT
OFF
ON
ESS BUS
BUS-TIE
RECOVERY
CONTACTOR
No. 1 CONTACTOR
START No.1 GEN No.1 DC PRIMARY
GEN CONTACTOR BUS
No.2 AC
PRIMARY BUS
INV BUS
No. 2 INVERTER
CONTACTOR
No. 2 26-VAC AC
BUS TRANSFORMER
GEN
AC GEN
"BATT OFF"
CONTACTOR
INV
CONTACTOR
AC MONITOR
BUS
No. 1 AC
PRIMARY BUS
INV BUS No.1
CONTACTOR INVERTER
No.1 26-VAC BUS
TRANSFORMER
No. 2
No. 2 GEN No.2 DC PRIMARY
START
GEN CONTACTOR BUS
ON BATT BUS
BATT
BATT
CONTACTOR
EXT POWER
DC EXT
POWER CONTACTOR
DC ESS BUS
ESS BUS
BUS-TIE
RECOVERY
CONTACTOR
No. 1 CONTACTOR
START No.1 GEN No.1 DC PRIMARY
GEN CONTACTOR BUS
AC GEN
CONTACTOR
OFF
ON
No.2 AC
PRIMARY BUS
INV BUS
No. 2 INVERTER
CONTACTOR
No. 2 26-VAC AC
BUS GEN
TRANSFORMER
AC GEN
CONTACTOR
RESET RESET
OFF OFF
ON ON
STARTER / GENERATORS
MONTADO NA CAIXA DE ACESSRIOS DE CADA MOTOR.
FUNCIONA COMO MOTOR DE PARTIDA AO RECEBER
CORRENTE CONTNUA DA BATERIA OU FONTE EXTERNA.
COM O MOTOR EM MARCHA LENTA TRABALHA COMO
GERADOR DE CORRENTE CONTNUA.
A UNIDADE DE CONTROLE DO GERADOR REGULA A
VOLTAGEM DE SADA E PROTEGE CONTRA O EXCESSO OU
QUEDA DE VOLTAGEM, CORRENTE REVERSA E FALHAS DE
TERRA.
CHAVE (SWITCH) DO GERADOR DC
POSSUI TRS POSIES:
ON LIGA O GERADOR LINHA DE
GEN
DISTRIBUIO QUANDO A UNIDADE DE
DC 1
CONTROLE SENTE QUE A SADA DE FORA
EST DENTRO DOS LIMITES, E APAGA A LUZ DC
RESET GEN.
OFFREMOVE O GERADOR DA LINHA E O
OFF DESLIGA. (LUZ DC GEN ACENDE)
RESETQUANDO O GERADOR SAI DA LINHA
ON POR PROBLEMA MOMENTNEO (E A LUZ DC
GEN ACENDE) COLOCAR O SWITCH EM
RESET E DEPOIS EM ON RESTAURAR A
OPERAO DO GERADOR. OS CIRCUITOS
RESET SO LIGADOS BARRA ESSENCIAL E
PROTEGIDOS PELOS DISJUNTORES DC GEN
RESET.
LUZ DE PRECAUO DO GERADOR DC
1 DC GEN 2 DC GEN
No.2 AC
PRIMARY BUS
INV BUS
No. 2 INVERTER
CONTACTOR
No. 2 26-VAC AC
BUS GEN
TRANSFORMER
AC GEN
# 1 DC GEN "ON"
CONTACTOR
INV
CONTACTOR
AC MONITOR
BUS
No. 1 AC
PRIMARY BUS
INV BUS No.1
CONTACTOR INVERTER
No.1 26-VAC BUS
TRANSFORMER
DISTRIBUIO DA CORRENTE CONTNUA
ATRAVS DE TRS BARRAS
PRIMRIA DC N 1 GERADOR DC # 1
PRIMRIA DC N 2 GERADOR DC # 2
ESSENCIAL DC GERADOR DC # 1 (ATRAVS CONTACTOR
BUS TIE)
NA FALHA DE QUALQUER GERADOR, O OUTRO ASSUME AS
TRS BARRAS, MESMO COM A CHAVE DO GERADOR QUE
FALHOU EM OFF;
EM VO NORMAL O GERADOR #1 CARREGA A BATERIA E
ALIMENTA A BARRA DA BATERIA;
A FONTE EXTERNA ALIMENTA AS TRS BARRAS, A MENOS QUE
UM OU AMBOS OS GERADORES ESTEJAM NA LINHA;
COM OS DOIS GERADORES INOPERANTES E SEM A FONTE
EXTERNA, APENAS A BARRA ESSENCIAL SER ALIMENTADA
PELA BATERIA. ESTA CONDIO ANUNCIADA PELO
ACENDIMENTO DA AMBAS AS LUZES DC GEN E A BUS TIE
OPEN.
O No. 2
START
No. 2 GEN
CONTACTOR
No.2 DC PRIMARY
BUS
P
GEN
BATT BUS
BATT
E
BATT
CONTACTOR
R
DC EXT EXT POWER
DC ESS BUS
POWER CONTACTOR
A ESS BUS
RECOVERY
BUS-TIE
CONTACTOR
No. 1 CONTACTOR
START No.1 GEN No.1 DC PRIMARY
No.2 AC
O PRIMARY BUS
INV BUS
No. 2 INVERTER
CONTACTOR
No. 2 26-VAC
N
AC
BUS GEN
TRANSFORMER
O
AC GEN
CONTACTOR
M
AC MONITOR BUS
No. 1 AC
A PRIMARY BUS
INV BUS No.1
BATT HOT
BATT OFF
#2 DC
GEN
ESS BUS
VOLTS
#1 DC LOW
GEN
BUS TIE
OPEN
#1 DC WARNING LIGHT
GEN HOT
CONTACTOR FUNO
1. Liga o gerador barra primria se a sada aceitvel
GENERATOR pela unidade de controle.
(2) 2. Liga qualquer gerador a ambas as barras primrias se
o outro gerador falhou ou estiver desligado.
OFF
ON
GERADOR AC (OPCIONAL)
MONTADO NA TRANSMISSO E POR ELA ACIONADO.
UNIDADE DE CONTROLE DO GERADOR REGULA A SADA E
PROTEGE CONTRA EXCESSO DE VOLTAGEM, QUEDA DE
VOLTAGEM, QUEDA DE FREQNCIA E FALHA DE
ALIMENTAO.
POSSUI UM ENTRELAAMENTO COM O SISTEMA DE ALARME
DE PERDA DE MOTOR (ENG OUT) QUE TIRAR O AC GEN
DA LINHA, A MENOS QUE O KIT DE PROTEO CONTRA A
NEVE ESTEJA INSTALADO E OPERANDO.
A CORRENTE TRIFSICA NECESSRIA QUANDO O
AQUECIMENTO DO PAR-BRISAS EST INSTALADO.
AC
TANEAMENTE ;
O GERADOR DEVER SAIR UNDER
VOLT
DA LINHA, CONFIRMADO FEEDER
VOLT
PELO ACENDIMENTO DA LUZ
AC GEN;
PARA RESTAURAR A
OPERAO PASSAR SW
PARA OFF E DEPOIS ON.
LUZ DE PRECAUO DO GERADOR AC
AC GEN
ACENDE (NOS DISPLAYS DO MOTOR OU COMPOSTO
DO IIDS) QUANDO A BARRA ESSENCIAL EST
ALIMENTADA E O GERADOR AC INOPERANTE OU
FORA DA LINHA DE DISTRIBUIO.
A DETECO DE UMA FALHA DE MOTOR TAMBM
RESULTAR NA PERDA DO GERADOR AC, A MENOS
QUE O SISTEMA DE PROTEO CONTRA A NEVE
ESTEJA INSTALADO E FUNCIONANDO (ON).
A LUZ AC GEN EST LIGADA S BARRAS PRIMRIA
DC #2 E ESSENCIAL, ATRAVS DOS DISJUNTORES AC
GEN WARN.
LUZ DE PRECAUO DO ROLAMENTO
DO GERADOR AC
AC GEN BEARING
O EIXO DO GERADOR AC POSSUI ROLAMENTOS
PRINCIPAIS E ROLAMENTOS AUXILIARES.
QUANDO FALHAM OS ROLAMENTOS PRINCIPAIS, OS
AUXILIARES ASSUMEM A CARGA DO EIXO E FAZEM
ACENDER A LUZ AC GEN BEARING NO DISPLAY DO
MOTOR OU NO DISPLAY COMPOSTO DO IIDS.
A OPERAO COM OS ROLAMENTOS AUXILIARES EST
LIMITADA EM 5 HORAS (DA A IMPORTNCIA DE
REGISTRAR O MOMENTO DA FALHA).
A LUZ AC GEN BEARING LIGADA S BARRAS
PRIMRIAS DC #2 E ESSENCIAL ATRAVS DOS
DISJUNTORES AC GEN WARN.
-- INVERTERS ---
NO. 1 NO. 2
OFF OFF
ON ON
INVERSORES ESTTICOS
O SISTEMA AC POSSUI DOIS INVERSORES
MONOFSICOS; CADA UM COM SEU SWITCH DE
DUAS POSIES ON/OFF NO PAINEL MESTRE DE
SWITCHES DO TETO.
OS INVERSORES TM SUAS FASES SINCRONIZADAS
PARA NO CAUSAR DISTRBIOS NO SISTEMA AC.
O INVERSOR N 1 ALIMENTADO PELA BARRA
PRIMRIA DC #2, E O INVERSOR NO. 2 PELA BARRA
ESSENCIAL.
LUZ DE PRECAUO DO INVERSOR
P
GEN
BATT BUS
BATT
E
BATT
CONTACTOR
R
DC EXT EXT POWER
DC ESS BUS
POWER CONTACTOR
A ESS BUS
RECOVERY
BUS-TIE
CONTACTOR
No. 1 CONTACTOR
START No.1 GEN No.1 DC PRIMARY
No.2 AC
O PRIMARY BUS
INV BUS
No. 2 INVERTER
CONTACTOR
No. 2 26-VAC
N
AC
BUS GEN
TRANSFORMER
O
AC GEN
CONTACTOR
M
AC MONITOR BUS
No. 1 AC
A PRIMARY BUS
INV BUS No.1
N 2 AC PRIMARY
BUS
INV BUS
N 2 INVERTER
CONTACTOR
AC
N 2 26-VAC BUS GEN
TRANSFORMER
AC GEN
CONTACTOR
No.2 AC
PRIMARY BUS
INV BUS
No. 2 INVERTER
CONTACTOR
No. 2 26-VAC AC
BUS GEN
TRANSFORMER
AC GEN
CONTACTOR
BSICO DO
SISTEMA DE NO. 2
INVERTER
INVERSORES
AC #1 INV
NO. 1
INVERTER
#1 INV FAIL
PROCEDIMENTOS NORMAIS (1)
Sintoma:
Luz de alarme BATT HOT acesa.
Ao:
Cheque se a luz de precauo
BATT OFF est acesa. Se estiver
apagada, passe o switch da bateria
para OFF.
Pouse logo que praticvel.
Se houver odores ou fumaa,
pouse logo que possvel.
FALHA DE UM GERADOR
Sintoma:
Luz de precauo 1 ou 2 DC GEN acesa.
Ao:
Passe a chave do gerador para OFF, aguarde 5
segundos e mova para RESET, depois ON.
Repita se necessrio.
Se no restaurar sada do gerador, passe a
chave para OFF.
Se IMC VMC logo que praticvel e continue o
vo.
O gerador remanescente suprir toda a carga.
Apenas por precauo desligar equipamentos
no necessrios.
Se instalada, utilizar Chave Mestra para desligar
avinicos no essenciais.
FALHA DOS DOIS GERADORES DC (1)
CUIDADO A FALHA EM RECUPERAR A BARRA ESSENCIAL
REDUNDA EM APENAS 30 MINUTOS DE OPERAO PARA O
INDICADOR DE ATITUDE DE RESERVA.
AES:
TENTE RECICLAR AMBOS OS GERADORES, UM DE CADA VEZ,
PASSANDO O SWITCH PARA OFF, AGUARDANDO 5
SEGUNDOS, LEVANDO PARA RESET E DEPOIS PARA ON.
FALHA DOS DOIS GERADORES DC (2)
COM A PERDA DE AMBOS OS GERADORES DC: SE EM
IMC, PASSE PARA VMC LOGO QUE POSSVEL.
SE EM OPERAO NOTURNA LIGUE AS LUZES DO
GLARESHIELD.
REDUZA A CARGA ELTRICA DESLIGANDO
EQUIPAMENTOS NO NECESSRIOS.
DESLIGUE OS INVERSORES, SE O GERADOR AC
ESTIVER NA LINHA.
POUSE LOGO QUE PRATICVEL.
SE EQUIPADO COM SWITCH EMERGENCY LOAD SHED,
SER POSSVEL AT, APROXIMADAMENTE, UMA HORA
DE VO NOTURNO EM IMC.
SWITCH EMER LOAD SHED (1)
DESDE QUE A BATERIA ESTEJA TOTALMENTE CARREGADA, O
PROCEDIMENTO A SEGUIR PERMITIR AT UMA HORA DE VO
NOTURNO IMC, APROXIMADAMENTE.
AO:
DESLIGUE O SWITCH DO GERADOR AFETADO.
SE A LUZ DC GEN HOT PERMANECER ACESA,
POUSE LOGO QUE PRATICVEL.
SE A LUZ PERMANECER ACESA E INDICAES DE
FOGO FOREM EVIDENTES TAIS COMO FUMAA
OU CHEIRO DE QUEIMADO CORTE O MOTOR
AFETADO.
CONEXO COM A BARRA ESSENCIAL ABERTA
AO:
SW ESS BUS RCVRY-ON (A luz localizadora ajuda a achar o
switch).
Cheque as luzes de precauo BUS TIE OPEN e 1 DC GEN
acesas.
Cheque os sistema alimentados pela barra ESSENCIAL
normais.
Se em IMC, passe para VMC logo que praticvel e continue o
vo.
Nota: Com o sistema de recuperao da barra essencial ativado
todas as barras DC (primrias 1 e 2, e essencial) ficam
alimentadas pelo gerador DC#2. Considere desligar
equipamentos no necessrios .
FALHA DO INVERSOR
SINTOMA:
LUZ DE 1 INV FAIL ou 2 INV FAIL ON
PRECAUO
AO:
Se em IMC, considere a transio para VMC logo que
praticvel e continue o vo.
Se falharem os dois inversores, passe para VMC e
permanea VMC.
NOTA:
- A falha subseqente de um motor, ou do gerador AC,
causar a perda de toda a corrente alternada.
- A falha subseqente do segundo inversor, resultar no
gerador AC alimentando todos os sistema AC.
- A falha subseqente do segundo inversor pode resultar
em ambos os autopilots (ou SAS) desengajados. Os
autopilots podem ser reengajados manualmente.
FALHA DO GERADOR AC
Se em IMC, considere passar para VMC logo que praticvel e continuar
o vo.
Se depois vier a falhar um inversor, passe para VMC ou permanea
VMC.
O sistema eltrico AC supre automaticamente as barras afetadas,
usando as barras remanescentes. Durante a transio o autopilot da
barra afetada pode desengajar, mas poder ser religado quando a
transferncia se completar.
SINTOMA: LUZ DE PRECAUO AC GEN ON
AO: Passe o SW do gerador AC para OFF, depois para ON.
Se o gerador no recuperar, desligue o switch.
Se em IMC, considere a transio para VMC logo que praticvel e
continue o vo.
Se depois um inversor vier a falhar, passe para VMC e permanea em
VMC.
NOTA:
- Uma falha de motor resultar na perda do gerador AC, a no ser que o kit
de proteo contra a neve esteja instalado e funcionando.
- Os inversores so capazes de fornecer corrente alternada para todos os
equipamentos, exceto o aquecimento do pra-brisas que fica na barra
monitora e desalimentado automaticamente nesta condio.
FOGO ELTRICO
- Os indcios costumam ser: cheiro de isolamento queimando
e/ou fumaa acre.
- Ao perceber desligue todos os equipamentos eltricos no
necessrios.
SE EM VMC, PROCEDA DA SEGUINTE MANEIRA:
Desligue os dois geradores DC, o gerador AC, os inversores e
puxe os dois disjuntores BUS TIE das barras primrias DC.
Escolha a ao apropriada abaixo:
Se o fogo persistir, ligue todos os geradores e inversores, e
desligue a bateria. O fogo dever se extinguir. Pouse logo
que possvel, usando o sistema pneumtico para estender o
trem de pouso.
Se o fogo se extinguir, restaure os equipamentos na
seqncia abaixo e permitindo um intervalo para observar os
efeitos (se voltar o fogo, desligar e pousar logo que possvel).
Gerador AC
Gerador DC #1, se o fogo continuar apagado empurrar
para dentro os dois CBs BUS TIE.
SE EM IMC, USE O DIAGRAMA SEGUINTE.
PERDA
TOTAL
FORA DC
PROSSIGA
IMEDIAT.
ABAIXO