Você está na página 1de 6

A UTILIZAO DE MICROTURBINA A GS NATURAL COMO COGERAO

Gervsio Saraiva Lara, Amncio R. da Silva Junior, Wellington Rocha Arajo, Saulo Gomes Moreira, Rafael Nishimura, Rafael D. Torres, Rodrigo C. Minari Laboratrio de Eficincia Energtica, Departamento de Engenharia Eltrica, Universidade Federal de Mato Grosso do Sul UFMS Campus Universitrio, Caixa Postal 549, CEP 79.070-900 Campo Grande-MS eficiencia@del.ufms.br Abstract: The Hospital (HU) of the Federal University of Mato Grosso do Sul (UFMS), located in Campo Grande, bought a microturbine of 100 kW of electrical generation, including a 587.000BTUh unity of termical production, with the purpose of optimizing the generation of electrical energy, operating in Stand alone or in paralel with the State Enterprise of Electrical Energy, so as to supply loads and produce heat for the laundry and the kitchen. We present herein a proposal of a cogeneration system, with the use of natural gas microturbine, aiming at the optimization of primary energy use in a study case in this Hospital. The Requirement Revenues method is utilized with the objective of evaluating the efficient use of natural gas. Copyright 2007 CBEE/ABEE Keywords: Energy Efficiency, Cogeneration, Requirement Revenue. Resumo: O Hospital Univeristrio da UFMS adquiriu uma microturbina de 100kW de gerao eltrica, dotada de uma unidade de produo de calor de 587.000BTUh (172kW), com a finalidade de gerao de energia eltrica, operando em Stand Alone ou em paralelo com a concessionria, para suprir cargas e produzir calor para as necessidades da lavanderia e da cozinha. Apresenta-se uma proposta de sistema de cogerao, com o uso de microturbina a gs natural, visando otimizar a utilizao da energia primria em um estudo de caso nesse Hospital, utilizando o mtodo de Receitas Requeridas para avaliar o uso eficiente do gs natural. Palavras Chaves: Eficincia Energtica, Cogerao, Receitas Requeridas.

INTRODUO

O Hospital da UFMS tem atendido a populao local e regional dando suporte aos cursos de medicina. O aumento do custo da energia eltrica no Brasil e a procura de fontes de energia renovveis e de baixa emisso de poluentes propiciaram o uso de outras fontes de energia antes consideradas inviveis, entre as quais o gs natural. A utilizao de microturbinas movidas a gs natural uma alternativa que se apresenta como fonte de suprimento para cargas de pequeno porte. O desenvolvimento da tecnologia das microturbinas, aliado ao fcil acesso do uso ao gs natural nas regies servidas pelo gasoduto BolviaBrasil, possibilita a utilizao de tais dispositivos em sistemas de gerao distribuda.

Nessa perspectiva, os principais objetivos a serem alcanados para a obteno de uma melhor eficientizao da energia eltrica consumida no Hospital Universitrio (HU), com a cogerao atravs da utilizao de microturbina a gs natural, so: 1) Avaliar alternativas tcnico-econmicas de cogerao possveis, com a utilizao da microturbina a gs natural instalada no HU. 2) Propor solues para otimizar a utilizao da microturbina a gs natural na produo de energia eltrica e trmica, reduzindo emisses poluentes da caldeira a leo existente. As figuras 1 e 2 apresentam a forma de interligao da Microturbina no Hospital Universitrio (HU/UFMS).

Renda lquida
Concessionria local leo tipo BPF gua Caldeira gua quente para cozinha e lavanderia: 2000 kg/hora

Projeta-se esses custos ao longo da vida til (considerada igual vida contbil) do investimento, utilizando regras clssicas de contabilidade. O processo de nivelao de valores (levelization) uma tcnica que consiste, para facilidade de anlise, em tomar uma srie de valores irregulares de despesas anuais, por motivos de aumentos reais ou de inflao, convert-los em uma soma (valor presente), no incio do perodo estudado, e redistribu-los de forma uniforme ao longo dos anos. Um pagamento equivalente anual submetido ao processo de nivelao, como gastos com combustvel em uma planta de cogerao, por exemplo, forma uma base para comparao entre alternativas de um determinado investimento.

Instalaes eltricas do Hospital: Potncia instalada de 3,3 MVA

Figura 1: Sistema Atual (Caldeira + Energia Electrica da Concessionria).


Concessionria local leo tipo BPF gua Caldeira gua quente para cozinha e lavanderia: 2000 kg/hora

3
Instalaes Eltricas do Hospital Microturbina

ANLISE DO PROBLEMA E RESULTADOS

gua Gs Natural

0,3 MVA

3,0 MVA

Energia Eltrica

Figura 2 Interligao da microturbina a gs natural de 100kW.

FUNDAMENTOS TERICOS DO MTODO DAS RECEITAS REQUERIDAS

O Electric Power Research Institute (EPRI), entre outros trabalhos que constam de seu acervo, tem o Relatrio TR-100281, que apresenta mtodos para avaliar a viabilidade tcnico-econmica de investimentos de capital em sistemas trmicos de gerao de energia eltrica. Independente de ser da iniciativa privada ou de rgo pblico, o investidor em projetos de cogerao de energia eltrica tem a necessidade de realizar anlises tcnicas e econmicas antes de realizar o investimento. Em anlise econmica, o retorno do capital investido varia de acordo com as taxas de juros do mercado e tambm com o tipo de tecnologia utilizada para a gerao de energia eltrica. O mtodo da Receitas Requeridas foi utilizado para avaliao tcnico-econmica de uso da cogeraao em um hospital universitrio. Este mtodo contabiliza todos os custos dos servios de gerao de energia eltrica, tais como: Combustvel; Despesas de operao e manuteno; Depreciao; Impostos Juros

A utilizao do mtodo de Receitas Requeridas adequada para a implantao programas de conservao de energia por meio da cogerao e a anlise que se faz, neste estudo, incide sobre a utilizao da microturbina a gs natural de 100kW da Elliott em cogerao de 587.000BTU/h, com uma velocidade nominal de 68.000 rpm e um consumo nominal de 39 Nm3/h.. A gerao de energia eltrica atender parcialmente subestao da Maternidade do Hospital Universitrio (HU) da Universidade de Federal do Mato Grosso do Sul (UFMS), e a energia trmica gerada, de 587.000BTU/h (172kW), ser injetada no sistema de aquecimento do Hospital (lavanderia, nutrio, aquecimento e esterilizao). Foram analisadas duas condies no funcionamento da microturbina: i) de forma contnua, isto , 24 horas por dia; ii) somente no horrio da ponta (das 17h:30min. s 20h:30min.). A Tabela 1 apresenta os consumos de gs natural para a microturbina Elliott TA-100RGCHP instalada no HU, para as duas simulaes realizadas.
Tabela 1 Consumo de gs natural da Microturbina Elliott TA 100RGCHP.

Condio de operao Contnua Horrio da ponta

Consumo dirio de gs Nm3/h 850 117

Consumo mensal de gs Nm3/h 25.500 2.574

So as seguintes premissas e caractersticas principais consideradas neste trabalho:

utilizao do mtodo das Receitas Requeridas e comparao entre alternativas por meio do valor do MWh em reais, submetido ao processo de nivelao; obteno, inicialmente quanto ao sistema atual (caldeira + energia eltrica da concessionria), do valor que foi desembolsado, em 2004, pelo HU/UFMS, submetido ao processo de nivelao: MWh equivalente ao combustvel utilizado nas caldeiras existentes + MWh da energia eltrica pago concessionria; obteno, numa segunda etapa, do valor do MWh para propostas alternativas de operao da microturbina, em complementao ao sistema atual (caldeira + energia eltrica da concessionria), sendo que a tecnologia a ser empregada na nova gerao atender parcialmente s demandas por energia eltrica e energia trmica (utilizada na cozinha e na lavanderia).

3.2

Balano Energtico do HU

A tabela 2 apresenta os valores para o Balano Energtico do HU/UFMS nas alternativas estudadas, tendo como referncia o ano de 2004.
Tabela 2: Balano energtico do HU/UFMS.

Operao Atual Ponta Fora de Ponta Anual Demanda (kW) Consumo (MWh) Demanda (kW) Consumo (MWh) Consumo (MWh) Total (R$) Custo (R$/MWh) 550 275 1.000 2.930 3.205
894.513,00

Operao contnua 450 203 900 2.224 2.427


716.621,16

Operao na ponta 450 203 1.000 2.930 3.133


825.494,63

3.1

Premissas

O trabalho visa analisar a influncia da variao do preo do gs natural (GN) considerando o Mtodo das Receitas Requeridas e para tanto se adotou que os ndices tanto na literatura internacional quanto na situao especfica do Brasil. 1) Para a vida contbil da nova tecnologia a ser implantada (microturbina a gs natural), bem como para sua depreciao, ser considerado o perodo de 30 anos. 2) Para os indicadores financeiros, sero levados em conta, ao longo da vida contbil: uma inflao de 5% ao ano; um aumento real de custos dos combustveis envolvidos de 1,6% ao ano, alm da inflao; uma taxa de desconto, antes do imposto, de 11,5%; uma taxa de desconto, depois do imposto, de 9,8%; e os impostos em 38 %. O fator de capacidade, por sua vez, foi considerado igual a 90 %, em funo das caractersticas de funcionamento da maternidade do Hospital Os valores nominais de eficincia da tecnologia utilizada (microturbina Elliott TA 100RGCHP) indicados nos manuais tcnicos chegam a 27%, para a gerao de energia eltrica, e a 74,5%, para cogerao (gerao de energia eltrica e trmica) nas condies ISO. O custo unitrio da microturbina foi considerado igual a R$ 2.500/kW. O custo total da planta (CTP) chegou a R$ 400.000,00, incluindo despesas com infraestrutura. Estimaram-se o prazo de construo em 1 ano e as despesas da instituio em R$ 8.000,00 (2% do CTP), o que corresponde aos gastos com terras, inventrio e partida da planta por unidade.

279,10

295,24 11.040 106 1.272 1,48


196.100,00

263,43 21.300 205 2.457 1,48


378.288,00

Consumo Mensal de leo BPF 2A 22.500 (kg) Equivalncia Eltrica Mensal 216 (MWh) Equivalncia Eltrica Anual 2.594 (MWh) Custo do leo BPF 1,48 2A (R$/kg) Gasto Anual com leo BPF 2A (R$) 399.600,00 Custo de Energia 154,02 Trmica (R$/MWh) Consumo Mensal de Gs Natural (Nm3) Gerao Mensal (MWh) Gerao Anual (MWh) Demanda (kW) Equivalncia Trmica Mensal (MWh) Equivalncia Trmica Anual (MWh) Gasto Anual com Gs Natural (R$) Custo de Energia de Cogerao (R$/MWh) Cogerao Anual (MWh) -

154,02 25.500 65 780 100 110 1.322 366.949,44 174,74 2.100

154,02 2.574 6 71 100 11 135 47.490,30 227,23 209

3.3

Clculo do Valor do MWh (Total) das Simulaes

3.3.2 Simulaes
Na segunda etapa, obter-se- o valor do MWh para uma proposta de planta em complementao ao sistema atual (caldeira + energia eltrica da concessionria), sendo que a tecnologia a ser empregada na nova planta suprir parcialmente as demandas por energia eltrica (atendendo subestao da maternidade do HU de forma isolada, inicialmente) e trmica (atendendo cozinha e lavanderia) e utilizar como combustvel o gs natural na microturbina Elliott TA 100RGCHP em duas simulaes, sendo que, na primeira, a microturbina funcionar continuamente e, na segunda, somente no horrio de ponta (das 17h30min. s 20h30min.). A microturbina do HU/UFMS operar continuamente no modo de cogerao, em complementao ao sistema atual, de acordo com o esquema apresentado na figura 2.

Para efeito de clculos, optou-se por analisar o efeito de uma inflao de 5% e um aumento real anual de 1,6%.

3.3.1 Primeira Etapa - Atual


Para o clculo do valor do MWh (total) do sistema atual (caldeira + energia eltrica da concessionria), utilizaram-se os dados contbeis e financeiros j indicados e da planta para a etapa atual, cujo esquema apresentado na Figura 1. A partir do clculo do custo de energia eltrica, do leo combustvel e do gs natural em R$/MWh, apresentados na tabela do Balano Energtico submeteu-se ao processo de nivelao e montou a tabela 3 com a utilizao do fator de nivelao para 30 anos igual a 2,076.
Tabela 3 Valor das Receitas Requeridas para todas as simulaes. Consumo anual em MWh Custo Total R$ Custo R$/ MWh Receitas Requeridas R$/MWh

3.3.3 Simulao da Variao do Preo do Gs Natural


Para a anlise de sensibilidade do custo do combustvel, cujo percentual em relao ao valor das Receitas Requeridas vai de 80%, para a operao contnua da microturbina, a 50%, na operao no horrio da ponta, ser considerada a variao do preo do gs natural de R$ 0,50 a R$ 2,00 por Nm3, j includo o processo de nivelao. A tabela 4 apresenta o resumo dessas variaes, e as figuras 3 e 4 mostram as curvas dessa simulao.
Tabela 4 Resumo da variao do gs natural versus Receitas Requeridas na operao contnua da microturbina.

Situao atual leo BPF 2A Energia eltrica leo BPF 2A Energia eltrica Gs Natural da MT leo BPF 2A Energia eltrica Gs Natural da MT 2.592 3.208 399.600,00 985.298,79 154,17 279,08 320,05 579,38

Operao Contnua da Microturbina 1.272 2.428 2.100 196.100,00 717.061,37 370.260,00 154,17 295,33 176,31 320,05 613,10 366,03

Preo do GN
R$/Nm3

Operao Contnua
R$/MWh

Operao no Horrio da Ponta


R$/MWh

Operao da Microturbina, no horrio de ponta 2460 3136 204 379.247,04 826.032,01 47.490,30 154,17 263,44 232,77 320,05 546,91 483,24

0,50 0,75 1,00 1,25 1,50 1,75 2,00

229,52 305,15 380,77 456,40 532,02 607,65 683,28

551,42 630,00 708,57 787,15 865,72 944,30 1.022,87

O mtodo de nivelao, ao ser aplicado num determinado perodo, acaba por refletir uma espcie de mdia, que considera perspectivas de evoluo dos valores ao longo do tempo, captando o efeito da inflao e de outras taxas. Deve-se acrescentar que, sendo o mesmo mtodo utilizado para todas as alternativas, os valores relativos mostram-se adequados para comparao. Deve-se interpretar, ento, a situao atual como um reflexo dos gastos esperados em 30 anos e no como o valor realmente pago, na atualidade, pelo HU/UFMS.

1200,00 1000,00 800,00

COMPARATIVO DO PREO DO GN
Preo do GN (Fora) Preo do GN (Ponta) Receitas Requeridas da MT (Fora) Receitas Requeridas da MT (Ponta)

3.5

R$/MWh

Resumo dos Quantitativos com a Variao do Preo do Gs Natural

600,00 400,00 200,00 0,00 0,50 0,75 1,00

R$/Nm

Figura 3: Resumo da variao do gs natural versus Receitas Requeridas.

Realizou-se uma variao do custo total do gs natural, a fim de verificar a sensibilidade das Receitas Requeridas Totais para a operao contnua da microturbina e para o horrio da ponta, conforme se v na tabela 6 e nas figura 4 e 5.

1,25

1,50

1,75

2,00

OBS: A curva referente ao preo do GN (fora) coincide com o preo do GN (ponta). Para a operao contnua da microturbina, observa-se que o custo do GN tem uma influncia muito maior do que no horrio da ponta. Essa influncia vai de 63%, para o valor de US$ 0,20/Nm3, a 87%, para US$ 0,80 Nm3, passando por 80%, para US$ 0,48/Nm3. Para o funcionamento da microturbina somente no horrio da ponta, a influncia vai de 26%, para o preo do gs de R$ 0,5 Nm3, a 58%, para R$ 2,00/Nm3, passando por 52%, para R$ 1,55/Nm3.

Tabela 6 Variao do preo total do gs natural nas duas condies estudadas.

Preo do Gs Natural R$/Nm3 0,50 0,75 1,00 1,25 1,50

Operao Contnua (R$) 2.337.651,84 2.477.028,84 2.616.426,84 2.755.824.84 2.895.222,84 3.034.620,84 3.173.997,84

Operao na Ponta (R$) 2.607.533,97 2.621.458,74 2.635.382,52 2.649.306,80 2.663.231,12 2.667.155,34 2.689.890,93

3.4

Resumo dos Quantitativos de cada Simulao

1,75 2,00

A tabela 5, a seguir, apresenta os quantitativos anuais do balano energtico do HU/UFMS (com o processo de nivelao) das trs simulaes realizadas.
Tabela 5 Balano Energtico com a metodologia dos Requisitos de Receitas.
3.200.000 3.100.000 3.000.000 2.900.000

RECEITAS REQUERIDAS x CUSTO DO GN


Operao Contnua Operao Contnua x Variao do GN

Simulao Atual Consumo Anual em MWh Custo do MWh em R$/MWh $ Gasto Anual Total em R$ Consumo Anual em MWh Custo do MWh em R$/MWh $ Gasto Anual Total em R$ Consumo Anual em MWh Custo do MWh em R$/MWh $ Gasto Anual Total em R$ Total Geral da Simulao em MWh

Operao Contnua 2.428 613,10


1.488.606,80

Operao na Ponta 3.136 546,91


1.714.842,89

Energia Eltrica Anual 3.208 579,38


1.858.651,04

R$

2.800.000 2.700.000 2.600.000 2.500.000 2.400.000 2.300.000 0,50 0,75 1,00

R$/Nm
1,25

3 1,50 1,75 2,00

Figura 4: Variao do preo do gs natural com operao contnua.

Energia Trmica Anual


3.200.000

RECEITAS REQUERIDAS x CUSTO DO GN


Operao na Ponta Operao na Ponta x Variao do GN

2592 320,05
829.569,60

1.272 320,05
407.103,60

2.460 320,05
R$

3.100.000 3.000.000 2.900.000 2.800.000 2.700.000 2.600.000 2.500.000

787.316,86

Cogerao Anual 2.688.220,64

2.400.000 2.300.000

R$/Nm
0,50 0,75 1,00 1,25

3 1,50 1,75 2,00

2.100 444,30 933.030,00


2.828.740,40

209 877,51
183.399,59

Figura 5: Variao do preo do gs natural com operao no horrio da ponta.

2.685.559,34

Verifica-se que a variao do custo do gs natural muito mais significativa para a operao contnua da microturbina quando se considera o mtodo das Receitas Requeridas Totais.

CONCLUSES E RECOMENDAES

Com a utilizao do mtodo das Receitas Requeridas e com as devidas adaptaes realidade brasileira, fez-se a avaliao da viabilidade tcnico-econmica das simulaes possveis para o funcionamento contnuo (24 horas/dia) da microturbina Elliott TA 100RGCHP, no HU/UFMS. Essa alternativa vivel para a eficincia energtica, pois contribui para a diminuio do efeito estufa, com a reduo, na ordem de 50%, das emisses da caldeira a leo BPF, apesar do valor final das Receitas Requeridas Totais ser superior ao da alternativa atual. Verificou-se tambm que a variao do preo do gs natural influencia fortemente nos valores das Receitas Requeridas Totais, na condio de operao contnua, sendo um fator econmico importante a ser considerado para a celebrao do contrato de compra desse insumo. Constata-se, portanto, que uma proposta da cogerao de energia um empreendimento que merece ateno especial, podendo representar uma forma atrativa de investimento e servindo ainda como alternativa de incremento na matriz energtica brasileira. Trata-se, alm disso, de uma forma de evitar restries de consumo de energia eltrica, como ocorreu durante o racionamento de 2001.

REFERNCIAS

COSTA, M. H. A. and BALESTIERI, J. A. P. (2001). Comparative study of cogeneration systems in a chemical industry, Applied Thermal Engineering, v.21, n.4, p. 523-533, Mar. 2001. TOLMASQUIM M.T.; SZKLO A.S.; SOARES, J. B. (2001). Economic potencial of natural gas tired cogeneration plants at malls in Rio de Janeiro. Energy Conversion & Management, v.42, n.6, p. 663-674. EPRI (Electric Power Research Institute). TR-100281. Revision 6. EUA, Dec,1991. v.3. CLEMENTINO, L., D. (2001). A conservao de energia por meio da cogerao de energia eltrica. Editora rica. So Paulo. ELLIOTT ENERGY SISTEMS, 100kW Turbo Alternator Gas Combined Heat and Guide Part 1 Product 2003. Inc. TARGCHP Recuperated Natural Power Application Description, Flrida,

ELLIOTT ENERGY SISTEMS, Inc. TARGCHP 100kW Turbo Alternator Recuperated Natural Gas Combined Heat and Power Application Guide Part 2 Basic Installation Electrical, Flrida, 2003.

Você também pode gostar