SISTEMA DE SEGURANA
ndice de Contedo
Seco 1: Instalao e Cablagem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Instalao . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Ligao do sistema PC1616/1832/1864 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.1 Ligao do Keybus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.2 Ligao das zonas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.3 Expansores de zonas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.4 Ligao da Sirene . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.5 Ligao da alimentao AUX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.6 Ligao PGM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.7 Ligao do detector de monxido de carbono . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.8 Ligao da linha telefnica . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.9 Ligao Terra . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.10 Bateria . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.11 Conexo CA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.12 Procedimento Registo Rpida . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
1
2
3
3
3
4
4
4
4
5
5
5
5
5
6
6
6
6
6
8
Seco 3: Programao . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3.1 Como programar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3.2 Programao de opes de alternncia: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3.3 Programao de dados decimais e hexadecimais (HEX): . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3.4 Como sair da programao do instalador: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3.5 Visualizao da programao . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3.6 Programao DLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3.7 Diagnstico da tenso da bateria DLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Seco 4 Descries da programao . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Seco 5: Folhas de programao . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Apndice A: Cdigos de transmisso . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Apndice B: Guia de soluo de problemas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Apndice C: Programao de modelos . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Apndice D: Opes de Formato do Comunicador . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
INSTRUES DE SEGURANA PARA PROFISSIONAIS DE ASSISTNCIA TCNICA . . . . . . . . . . . . . . . . . . . . . . . . . 67
ii
'HWHFWRUHVGHIXPDD
Pesquisas tem mostrado que todos os incndios em residncias geram fumaa em quantidades maiores ou menores. Experincias com incndios tipicamente
residenciais tm mostrado que fumaa em uma quantidade detectvel precede o calor em uma quantidade detectvel, na maioria dos casos. Por estes motivos,
alarmes de fumaa devem ser instalados do lado de fora de cada quarto e em cada local de depsito de produtos da casa. A informao a seguir somente uma
directriz geral, e recomenda-se que cdigos e regulamentos de incndio locais sejam consultados quando determinar os locais e instalar alarmes de fumaa.
recomendado que alarmes de fumaa adicionais, alm daqueles necessrios para uma proteco mnima, sejam instalados. reas adicionais que devem ser
protegidas incluem: o poro; quartos, principalmente onde dormem fumantes; salas de jantar; salas onde h a presena de um equipamento de aquecimento e
locais de armazenamento de materiais; e qualquer corredor no protegido por unidades necessrias.
Em tetos lisos, os detectores devem estar espaados em distncias de 9,1m um do outro, como directriz geral. Outras distncias podero ser necessrias,
dependendo da altura do teto, movimentao do ar, presena de juntas, isolao trmica, etc. Consulte o Cdigo de Alarme de Incndio Nacional NFPA 72, CAN/
ULC-S553-02 ou outras normas nacionais aplicveis sobre as recomendaes de instalao.
No instale detectores de fumaa no alto de tetos pontudos ou em formato triangular; o espao de ar morto nestes locais podero fazer com que a unidade no
detecte a fumaa
Evite reas com fluxo de ar turbulento, como prximo a portas, ventiladores ou janelas. A movimentao rpida do ar ao redor do detector poder fazer com
que a fumaa no entre na unidade
No instale detectores em reas de grande humidade
No instale detectores em reas onde a temperatura possa ultrapassar 38C (100F) ou possa cair abaixo de 5C (41F)
Onde exigido pelas leis, cdigos ou normas aplicveis para um tipo especfico de ocupao, os detectores de fumaa de estaes individuais e mltiplas aprovados
devem ser instalados como segue:
1. Em todos os dormitrios e dormitrios de hspedes.
2. No lado externo de cada dormitrio da casa/apartamento dentro de uma distncia de 6.4 m de qualquer porta de um dormitrio, com a distncia medida ao
longo de um trajeto a ser percorrido.
3. Em cada andar da casa/apartamento, incluindo pores.
4. Em cada andar de uma casa de repouso (pequena) incluindo os pores e excluindo espaos de teto baixo e ticos no acabados.
5. Na(s) rea(s) sociais do dormitrio de hspedes.
6. Na(s) rea(s) sociais de uma casa de repouso (pequena).
Dormitrio
Sala da famlia
Dormitrio
Dormitrio
Dormitrio
Sala de
jantar
Dormitrio
Sala de
estar
Dormitrio
Sala de
jantar
Sala de
estar
Cozinha
Cozinha
Sala de
estar
Poro
Dormitrio
Dormitrio
Figura 3
Figura 2
Figura 1
Teto
Dormitrio Corredor Dormitrio
Sala de estar
Opcional
Aceitvel
aqui
,
Mx.
NUNCA
AQUI
Sala de recreao
Poro
ORGANIZAO DOS
NVEIS DE DIVISO
Figura 3a
Mx.
Topo do detector
aceitvel aqui
NOTA: as medidas exbidas
so referentes borda mais
prxima do detector
Parede
Figura 4
'HWHFWRUHVGH&2
O gs CO se movimenta livremente no ar. Locais sugeridos so aqueles em ou o mais prximo possvel dos
dormitrios da residncia. O corpo humano fica mais vulnervel aos efeitos do gs CO durante as horas de sono.
Para garantir a mxima proteo, um alarme de CO deve ser instalado fora dos dormitrios ou em cada andar da
residncia. A figura 3 indica os locais sugeridos na residncia. O sensor eletrnico detecta monxido de carbono,
mede a concentrao e emite um alarme em alto volume antes que um nvel potencialmente prejudicial seja atingido.
NO instale o alarme de CO nas reas a seguir:
Onde a temperatura possa atingir menos de -10C ou mais de 40C.
Prximo a fumaas resultantes de diluentes de tinta.
Dentro da distncia de 1,5 m de aparelhos de chama aberta, como fornos, foges e lareiras.
Prximo a fluxos de exausto de motores a gs, ventiladores, tubos ou chamins.
No instale o dispositivo prximo a um escapamento de automvel. Isso danifica o detector.
iii
Dormitrio
Dormitrio
Dormitrio
Cozinha
Trreo
Garagem
Poro
Detector de monxide de carbono
Figura 5
Resumo tcnico
Este produto adequado para uso
em sistemas com as seguintes
opes de notificao:
A (O uso de dois dispositivos de
aviso e de um comunicador interno
necessrio)
B (Um dispositivo de aviso e auto
alimentado e um comunicador
interno so necessrios)
D (O uso de um comunicador
Ethernet encriptado modelo TL/GS
TL250, TL260, TL260GS, GS2060
da DSC necessrio)
COMPONENTES FORNECIDOS
Qde 1
Qde 1
Qde 1
Qde 1
Qde 2
Qde 1
Qde 5
Qde 16
Qde 1
Qde 1
Qde 1
Qde 1
Armrio
Mdulo PC
Manual de instalao
Manual de utilizador
Identificao do Armrio
Plugue da Porta do
Armrio
Espaadores
Resistncias de 5,6K
Resistncia de 2,2K
Resistncia de 1,0K
Resistncia de 10
Kit para ligao Terra
CARACTERISTICAS
PC1616
PC1832
PC1864
Zonas na Placa
Zonas com Fio
Zonas sem Fio
Suporte para as zonas
de teclado
6
16 (1xPC5108)
32
8
32 (3xPC5108)
32
8
64 (7xPC5108)
64
PGM 1 - 50mA
PGM 2 - 300mA
PGM 1 - 50mA
PGM 2 - 300mA
PGM 1, 3, 4 - 50mA
PGM 2 - 300mA
8x50mA (PC5208)
8x50mA (PC5208)
4x500 mA (PC5204) 4x500 mA (PC5204)
8
8
2
4
47 + cdigos mestre 71 + cdigos mestre
500 Eventos
500 Eventos
Expanso PGM
Teclados
Parties
Cdigos de Utilizador
Memria de Eventos
Transformador
Necessrio
Bateria Necessria
Sada de Sirene
8x50mA (PC5208)
4x500 mA (PC5204)
8
8
94 + cdigos mestre
500 Eventos
16,5VCA/40VA
16,5VCA/40VA
16,5VCA/40VA
4Ah/7Ah/14AHr
4Ah/7Ah/14AHr
4Ah/7Ah/14AHr
12V/700mA (cont)
12V/700mA (cont)
12V/700mA (cont)
Mdulos
TL-250/TL300........................................................................... 275/350mA
GS2060/GS2065 (somente GPRS/GSM) ......................................... 65mA
GS2060-SM (somente GPRS) .......................................................... 90mA
TL260GS/TL265GS (Ethernet/GPRS) ............................................ 100mA
TL260-SM (somente Ethernet) ....................................................... 100mA
TL260GS-SM (somente Ethernet/GPRS) ....................................... 120mA
Interface de 2 fios PC5100............40mA mais dispositivos at 170mA max
Receptor sem fios RF5132-433 ..................................................... 125mA
Receptor sem fios RF5108-433 ...................................................... 125mA
Transceptor sem fio TR5164............................................................. 60mA
Expansor de zonas PC5108 ............................................................ 30mA
Fonte de alimentao PC5200.......................................................... 20mA
Fonte de alimentao PC5204 com 4 sadas programveis ........... 30mA
Mdulo de sada programvel de baixa corrente PC5208 ............... 50mA
Escort5580 Mdulo de Interface Telefnica ................................... 130mA
Armrios
PC5003C ................................................................ 222 x 298 x 78 mm
Modelo PowerUC1..................................................... 315x319x100mm
PC500C (solamente roubo residencial) .................. 213 x 235 x 78 mm
PC4050CAR (roubo comercial UL)....................... 305 x 376 x 124 mm
CMC-1 (roubo comercial UL) .................................. 287 x 297 x 76 mm
Suttle, SAE 14 ........................355.6 x 362 x 95mm (14x14.25x 3.75in)
Suttle, SAE 21 ........................533.4 x 362 x 95mm (21x14.25x 3.75in)
Suttle, SAE 28 ........................711.2 x 362 x 95mm (28x14.25x 3.75in)
Suttle, SAE 42 ......................1066.8 x 362 x 95mm (42x14.25x 3.75in)
Instalao
Inicie a instalao montando os mdulos adicionais no Armrio utilizando os espaadores fornecidos e, em seguida, monte o Armrio em
um local seco protegido com acesso alimentao CA no bloqueada. Instale o hardware na sequncia indicada nas pginas a seguir.
NO ligue a alimentao at que a instalao esteja concluda.
NOTA: Todos os pontos de entrada do cabeamento esto determinados por setas. Todos os circuitos esto classificados com a limitao de
potncia UL, exceto para os condutores das baterias. Uma separao mnima de 6,4 mm deve ser mantida em todos os pontos entre o cabeamento da alimentao limitada, o cabeamento sem limitao de alimentao e as conexes.
1
PowerSeries - PC1616/PC1832/PC1864
Espaador
Placa PC
DSC
UA503
PC1616/1832/1864
220
ADVERTNCIA:
NOTA: No conecte o
transformador uma tomada
controlada por um interruptor.
PC1864
Only
PC1864
PC1832
Only
CON1
BAT+BAT-
TB-2
AC AC
AUX+
BELL+
PGM1
PGM3
AUXBELL- RED BLK YEL GRN
PGM2
PGM4 Z1 COM Z2
Z3 COM Z4
Z5 COM Z6
Z7 COM Z8 EGND
RING
TIP
R-1
T-1
CON1
BAT+BAT-
AC AC
12V / 7 AHr
Ao terminal
EGND
12V / 7 AHr
PRETO
16,5VCA/40VA
VERMELHO
Modelo DSC BD7-12
ou equivalente
Tempo de Standby
(Espera) da bateria:
24 horas no mnimo
FUSVEL
A conexo incorreta das baterias pode resultar na ruptura da bateria ou perigo de incndio.
NO deixe que objetos metlicos conectem-se aos terminais positivo e negativo.
Certifique-se de que as baterias sejam conectadas com a polaridade correta, Preto (-) e Vermelho (+).
Do contrrio, poder provocar a ruptura da bateria ou perigo de incndio.
Todos os circuitos tm a classificao de instalaes UL como Potncia limitada/Potncia
limitada da classe II, exceto para circuitos de bateria com potncia ilimitada.
IMPORTANTE:
NO passe qualquer cabo sobre as placas de circuito impresso. Mantenha uma separao de pelo menos 25,4 mm.
Uma distncia mnima de 6,4 mm deve ser mantida em todos os pontos entre o cabeamento
de potncia limitada e todos os outros fios sem potncia limitada.
UA503
220
PC1616/1832/1864
PC-LINK
DSC
REV XX
Conectados Internamente
Somente
PC1616
CON1
BAT+BAT-
AC AC
+AUX
AC
AUX
Somente
PC1835
PC1864
TB-2
_
+BELL
Sirene
Keybus
PGM1
PGM3
PGM2
PGM4 Z1 COM Z2
PGM
Z3 COM Z4
Z5 COM Z6
Zonas
Z7 COM Z8 EGND
RING
TIP
R-1
Telefone
T-1
2 CONTATOS NORMALMENTE
FECHADOS COM RESISTOR
DE FIM-DE-LINHA
QUALQUER
QUALQUER
TERMINAL Z TERMINAL COM
QUALQUER
QUALQUER
TERMINAL Z TERMINAL COM
QUALQUER
TERMINAL Z
QUALQUER
QUALQUER
TERMINAL Z TERMINAL COM
QUALQUER
TERMINAL COM
1 CONTATO NORMALMENTE
ABERTO COM RESISTOR
DE FIM-DE-LINHA DE
5600 OHMS
1 CONTATO NORMALMENTE
FECHADO COM RESISTOR
DE FIM-DE-LINHA DE
5600 OHMS
1 CONTATO NORMALMENTE
FECHADO SEM RESISTOR
DE FIM-DE-LINHA
QUALQUER
QUALQUER
TERMINAL Z TERMINAL COM
QUALQUER
TERMINAL COM
Contato
de Alarme
CIRCUITO DEOL
1 CONTATO NORMALMENTE
FECHADO COM RESISTOR
DE FIM-DE-LINHA DE
5600 OHMS
QUALQUER
TERMINAL Z
Contato
de Alarme
QUALQUER
TERMINAL COM
CIRCUITOS DEOL
2 CONTATOS NORMALMENTE
FECHADOS COM RESISTOR
Contato
de Anti-Violao DE FIM-DE-LINHA DE 5600
OHMS E RESISTOR
DE ANTI-VIOLAO
J1
ON
OFF
ON
OFF
ON
OFF
ON
OFF
J2
ON
ON
OFF
OFF
ON
ON
OFF
OFF
J3
ON
ON
ON
ON
OFF
OFF
OFF
OFF
Zonas atribudas
Zonas desativadas
Zonas 09-16
Zonas 17-24
Zonas 25-32
Zonas 33-40
Zonas 41-48
Zonas 49-56
Zonas 57-64
Consulte a folha de instalao associada para saber os locais dos jumpers para o mdulo PC5108 ver. 1
PowerSeries - PC1616/PC1832/PC1864
SIRENE/CIGARRA
700 mA (mx.)
Esses terminais fornecem 700 mA de corrente a 12 V CC para instalaes comerciais e 11,1-12,6 VCC
para instalaes residenciais (ex.: DSC SD-15 WULF). Para atender os requisitos do padro de trs
tempos NFPA 72: Programe Seo [013] Opo [8] ATIVADA.
NOTA: Alarmes contnuos, pulsantes tambm so suportados.
A sada da Sirene supervisionada e tem a alimentao limitada por 2A PTC. Se no for utilizada,
ligue um resistor de 1000 entre Bell+ e Bell- para que a Central no exiba uma mensagem de problema. Consulte [][2].
RESPEITE A
POLARIDADE
SIRENE
VERMELHO
Resistncia Indicador
de 680 ohms de LED
(valor nominal)
PRETO
BRANCO AMA.
VERDE
N.F N.A
A identificao de compatibilidade UL para a srie FSA-210B : FS200. Para as instalaes com certificao ULC utilize as sries FSA-210A e FSA-410A.
FSA-210C
FSA-210CT
FSA-210CS
FSA-210CST
FSA-210CLST
FSA-210CR
FSA-210CRT
FSA-210CRS
FSA-210CRST
FSA-210CLRST
NOTA:
Consulte o Manual de Instalao e
Folha de Instrues do Detector de
Fumo quando posicionar os detectores.
Entrada
de Zona
RESISTNCIA DE
FIM-DE-LINHA 2200
OHMS EOLR-3
NOTA: NO combine modelos de Fabricantes diferentes
no mesmo circuito. A operao poder ser instvel.
ALIMENTAO
12 Vcc PARA
DETECTOR DE
FUMAA
RESISTNCIA DO
CIRCUITO DE
INICIALIZAO DO
ALARME DE
100 OHMS
RESISTNCIA DE
FIM-DE-LINHA EOLR-2
5600 OHMS 0,5W
FSA-410C
FSA-410CT
FSA-410CS
FSA-410CST
FSA-410CLST
FSA-410CR
FSA-410CRT
FSA-410CRS
FSA-410CRST
FSA-410CLRST
DETECTOR DE CO
Qualquer
COM Z
DG009561
+-
AUX
Alimentao
Alarme
Problema
Os seguintes modelos de Detectores de CO podem ser utilizados com os painis
- + NC C NO NC C NO
de controle PC1616/PC1832/PC1864 v4.7 (e verses mais recentes):
PC1616/1832/1864
Modelo Potter CO-12/24, UL File E321434
Modelo Quantum 12-24SIR, UL File E186246
Modelo NAPCO FW-CO12 or FW-CO1224, UL File E306780
Modelo System Sensor CO1224, UL File E307195
RESISTOR
NOTA: Os detectores de CO sem fio tambm esto disponveis, por favor, refira-se ao
DE SEOL
Entrada
(5600 ohm)
Manual de Instalao do modelo RF5132 para maias detalhes
de zona
NOTA: Para proceder ligao de diversas unidades, no enrole o fio por baixo dos
RESISTNCIA
(SEOL TIPO 4)
DO CIRCUITO
terminais de controlo do sistema de alarme. Interrompa o curso do fio para poder
DE NICO
REL PILOTO RM-1/RM-2
DO ALARME
supervisionar as conexes.
DO CIRCUITO DE
100 ohm
ALIMENTAO
Para instalaes sem fios, use apenas detectores de CO sem fios DSC, modelos
(12V CC, 35 mA)
WS4913 e WS8913. necessrio um receptor sem fios DSC, modelo RF5132433/RF5132-868 (v5.1 ou mais alto), DSC tranceptor sem fio TR5164-433 (v1.0 ou mais alto) ou teclados RFK (v1.2 ou mais alto)
para os modelos sem fios. Para mais informaes consulte os respectivos manuais de instalao.
T-1
R-1
TIP
RING
CASTANHO
Sada para o
aparelho telefnico
CINZA
VERDE
VERMELHO
RJ-31X
Entrada do fio
telefnico da rede
1.10 Bateria
De acordo com a Norma EN50131-1, para Sistemas com Fonte de Alimentao Tipo A com
limites para Grau 2, o tempo necessrio da bateria em repouso, em caso da falha da fonte
de alimentao primria, deve ser de no mnimo 12 h. A Tabela abaixo indica as cargas
mximas para tempos em Repouso indicados. A carga inclui AUX+/-, Keybus (Vermelho,
Preto), PGM 1-4 e mdulos (consulte a tabela no incio desta publicao), no inclui uma
margem de segurana da bateria.
Corrente de Carga da Bateria: 400 mA (4Ah, bateria 7Ah)
Conexo de
ligao terra
Cabo de ligao terra
da instalao el ctr ica
do edif cio
Parafuso
Tamanho Bateria
4Hr
12Hr
24Hr
36Hr
4Ah
500mA
220mA
7Ah
500mA
480mA
150mA
14Ah
500mA
480mA
280mA
24Ah
500mA
500mA
Seco de Programao [701] Opo [7] para ligado se bateria de 14Ah ou 24Ah for
utilizada.
NOTA: Substitua as baterias a cada 3-5 anos. Se duas baterias forem necessrias para atender
ao tempo de reserva, utilize o Gabinete DSC Modelo Power UC1. A capacidade da bateria ser
reduzida com o tempo e com o nmero de ciclos de cargas e descargas executadas.
1.11 Conexo CA
Fonte de Alimentao: De acordo com a EN50131-6, Tipo A/Grau 2.
Primrio:220-240VCA/50Hz/0.2A
Secundrio: 16.5VAC/40VA min.
AVISO!: A ligao incorrecta das baterias pode resultar na ruptura da bateria ou em risco
de incndio. NO permita que objetos de metal toquem nos terminais positivo e negativo.
Insira [][8] [Cdigo do Instalador][898]. O visor LCD exibe o seguinte: Wireless Enrollment Mode. (Modo de registro sem fio).
Posicione o dispositivo sem fio no local desejado.
Ative o dispositivo conforme descrito na folha de instalao associada. O nmero de srie eletrnico (ESN) exibido.
Pressione [] para confirmar o ESN. Se o nmero de srie estiver incorreto, pressione [#] para descart-lo, e repita este passo.
Aps a confirmao do nmero de srie correto, o sistema solicitar o nmero da zona. A prxima zona disponvel ser exibida.
5. Insira um nmero de zona (01-64) e, em seguida, pressione [] para aceitar. A prxima zona disponvel ser pr-carregada.
NOTA: Somente um dispositivo pode ser registrado em cada zona. Se uma zona j tiver um dispositivo registrado, pressione [ ] para substituir a zona ou [#] para inserir outro nmero da zona.
6. Aps a insero bem-sucedida do nmero da zona, o sistema ir solicitar o tipo de zona. (O tipo de zona recomendada exibido).
Pressione [] para aceitar o tipo de zona ou insira:
Tipo de dispositivo
2 Contato de Janela/Porta
3 PIR ou Quebra de vidro
4 Detector de fumaa
5 Pendente
8 Detector de CO
Definio da zona
[01] Retardo 1
[05] Ambiente interno, Presena-Ausncia
[88] Incndio 24 horas padro (Sem fio)
[16] Pnico 24 horas
[81] Deteco de CO 24 horas
PowerSeries - PC1616/PC1832/PC1864
2.3 Desarmar
O utilizador deve entrar por uma porta programada como Retardo. Aps a entrada, o teclado emitir um tom fixo (e emitir um tom
pulsante durante os ltimos 10 segundos do retardo de entrada) para alertar o utilizador para desarmar o sistema. Digite um cdigo
de utilizador vlido para desarmar o sistema. Se algum alarme ocorrer enquanto a Central estiver armado, a luz da memria e as
zonas que entrarem em alarme comearo a piscar (teclado com LED) ou o teclado exibir Alarm in Memory (Alarme na memria)
(teclado com LCD). Pressione a tecla [#] para retornar o teclado ao estado Pronto.
Reactivar zonas no modo Stay/Away: Pressione [][1] quando o sistema estiver armado no modo Presente para mudar o estado
de armado para o modo Ausente. O sistema adicionar as zonas no modo Stay/Away de volta ao sistema depois que o tempo de
retardo de sada se esgotar.
6
Veja Anexo B - Guia de soluo de problemas, para assistncia a problemas e descrio detalhada de todos as condies de problema.
NOTA: Prima [9] para conhecer e reviso de todos os problemas existentes. Premir [9] permite Central armar, e gerar um histrico
de eventos. Uma superviso geral do Sistema causada por um expansor de zones cabladas ou via radio no pode ser gerada e visualizada com este mtodo. Se a seco [701] opo 3 estiver ON o armar sera inibido quando for detectado um problema de alimentao AC ou bateria fraca e este mtodo no poder ser executado.
NOTA: Prima [8] no Menu Problema de qualquer teclado da nova srie Power para inserir a data e hora no menu de programao.
Esta opo estar disponvel se um problema de falha de relgio estiver presente no sistema.
A luz de memria ACENDER quando um alarme ocorrer durante o ltimo perodo armado. Pressione [][3]. A luz de memria piscar e o teclado exibir as zonas que entraram em alarme.
NOTA:
Pressione [][4]. O teclado emitir trs bips rpidos se o recurso do som da porta estiver habilitado, e um tom fixo de dois segundos se
estiver desabilitado. A mesma funo pode ser executada pressionando e mantendo pressionada a tecla de funo Chime por dois
segundos.
Cdigo
Tipo
Funo
[01]-[39], [41]-[95]
Cdigos de utilizador
Armar, Desarmar
[40]
Todas as funes
PowerSeries - PC1616/PC1832/PC1864
Pressione [][6] seguido pelo cdigo de Utilizador Principal e pressione o nmero correspondente s funes.
[1]
Programao de hora e data: Digite a hora e a data utilizando o seguinte formato: [HH:MM] [MM/DD/AA]. Programe a hora
utilizando o padro militar (ex.: 8:00 PM = 20 horas).
[2]
Habilitar/Desabilitar o Armar/Desarmar automtico: O teclado emitir trs bips rpidos se o recurso de arme/desarme
automtico estiver habilitado, e um tom fixo de dois segundos se estiver desabilitado.
[3]
Hora dia do Armar Automtico: Pressione o nmero correspondente ao dia da semana (1=domingo, 2=segunda, etc.)
seguido pela hora do armar automtico. Programe a hora utilizando o padro militar (ex.: 8:00 PM = 20 horas).
[4]
Teste do sistema: A Central proceder da seguinte forma: activar a sada da sirene, o besouro do teclado e todas as luzes
de estado do teclado por dois segundos; testar a bateria de emergncia e transmitir um cdigo de transmisso Central
Receptora (se programado).
[5]
Habilitar o DLS: A Central habilitar temporariamente o DLS por um ou seis horas, dependendo da programao na seo
[702], Opc [7].
[6]
Pressione [][7][x]. Se a opo de cdigo de sada de comando necessria, para ACTIVAR, digite um cdigo de utilizador vlido. A
Central activar qualquer sada PGM atribuda sada de comando.
Pressione [][8] seguido pelo cdigo do instalador para entrar na programao do instalador. Consulte a Seco Como programar
para obter mais informaes.
Pressione [][9] seguido por um cdigo de utilizador vlido. O sistema ser armado no modo Stay (Presente) e depois que o tempo
do retardo de sada expirar, o sistema remover o retardo de entrada. Todas as zonas programadas como Retardo funcionaro como
zonas instantneas. O sistema piscar a luz Armed (Armado) para indicar que o sistema est armado sem retardo de entrada.
Arme rpido: Quando desarmado, pressione [][0] para armar o sistema. O sistema ser armado se um cdigo de utilizador vlido
for digitado.
Sada rpida: Quando armado, pressione [][0] para activar a sada rpida. O sistema permitir que uma nica zona programada
como Retardo seja violada uma vez durante o perodo de dois minutos seguinte sem mudar o estado do sistema.
Seco 3: Programao
Seco 3: Programao
Esta Seco fornece as informaes necessrias para programar todas as funes necessrias para um sistema bsico bem como
aplicaes comuns.
Opo ON
Opo OFF
LED
Indicador # ACESO
Indicador # APAGADO
# Exibido
Digite
Comunicador Telefnico
Hex[A]
Pressione [][1][]
No suportado
Hex[B]
Pressione [][2][]
Hex[C]
Pressione [][3][]
Hex[D]
Pressione [][4][]
Hex[E]
Pressione [][5][]
Hex[F]
Pressione [][6][]
Fim do nmero
Dgitos HEX (ou hexadecimais) s vezes so necessrios. Para inserir dgitos HEX, pressione a tecla [] para iniciar a programao
HEX. A luz Ready (Pronto) ir PISCAR. Consulte a tabela abaixo e pressione o nmero correspondente ao dgito HEX necessrio. A
luz Ready (Pronto) continuar a PISCAR. Pressione [] novamente para retornar programao decimal normal. A luz Pronto ser
ACESA.
NOTA: Alm dos dgitos padro 0-9, dgitos HEX tambm podem ser programados se necessrio.
PowerSeries - PC1616/PC1832/PC1864
10
Desarmar Global
Quando esta Tecla de funo for premida o painel ir perguntar por um cdigo de acesso de utilizador. O painel ir desarmar todas as
parties associadas a esse cdigo de acesso.
Descrio
[00]
[01]
Retardo 1: Quando armado, permite o retardo da entrada quando violado (segue o retardo de entrada 1)
[02]
Retardo 2: Quando armado, permite o retardo da entrada quando violado (segue o retardo de entrada 2)
[03]
[04]
Interno: Quando armado, alarme instantneo se a zona for violada primeiro, seguir o retardo de entrada se estiver activado
[05]
Interno, Stay/Away: Similar ao Interno, excepto pelo fato de que a Central ir inibir automaticamente a zona se armado no
modo Stay
[06]
Retardo, Stay/Away: Similar ao Retardo 1, excepto pelo fato de que a Central ir inibir automaticamente a zona se armado
no modo Stay
[07]
Incndio com retardo 24 horas (com fio): Alarme audvel instantneo quando violado, comunicao com retardo em 30
segundos se o alarme for detectado durante esse perodo (pressionando uma tecla), o alarme ser silenciado por 90
segundos e repetir o ciclo caso contrrio, o alarme ser travado e comunicado aps o retardo de 30 segundos
[08]
Incndio padro 24 horas (com fio): Alarme instantneo e comunicao quando violado
[09]
Superviso 24 horas (com fio): Alarme instantneo e comunicao quando violado. No accionar a sirene nem o besouro
do teclado.
[10]
Besouro de superviso 24 horas: Alarme instantneo, a Central activar o besouro do teclado ao invs da sada da sirene
[11]
Roubo 24 horas: Alarme instantneo quando violado, alarme audvel no modo padro. Cdigo de transmisso BA, BH
[12]
Assalto 24 horas: Alarme instantneo quando violado, alarme silenciado no modo padro. Cdigo de transmisso HA, HH
[13]
Gs 24 horas: Alarme instantneo quando violado, alarme audvel no modo padro. Cdigo de transmisso GA, GH
[14]
Calor 24 horas: Alarme instantneo quando violado, alarme audvel no modo padro (tambm conhecido como alta
temperatura). Cdigo de transmisso KA, KH
[15]
Urgncia mdica 24 horas: Alarme instantneo quando violado, alarme silenciado no modo padro. Cdigo de transmisso
MA, MH
[16]
Pnico 24 horas: Alarme instantneo quando violado, alarme audvel no modo padro. Cdigo de transmisso PA, PH
[17]
Emergncia 24 horas: Alarme instantneo quando violado, alarme audvel no modo padro. Cdigo de transmisso QA, QH
[18]
Extintor de incndio 24 horas: Alarme instantneo quando violado, alarme audvel no modo padro. Cdigo de transmisso
SA, SH
[19]
gua 24 horas: Alarme instantneo quando violado, alarme audvel no modo padro (tambm conhecido como nvel de
gua). Cdigo de transmisso WA, WH
[20]
Congelamento 24 horas: Alarme instantneo quando violado, alarme audvel no modo padro (tambm conhecido como
baixa temperatura). Cdigo de transmisso ZA, ZH
[21]
Travamento anti sabotagem 24 hrs: Alarme instantneo quando violado, a Central no pode ser armada at que se entre na
programao do instalador
[22]
[23]
Arme por chave para manuteno: Arma o sistema quando violado, desarma o sistema quando restaurado
11
PowerSeries - PC1616/PC1832/PC1864
[24]
[25]
Interno/Retardo: A zona funcionar como uma zona interna quando armada no modo Away, e como uma zona de retardo
quando armada no modo Stay
[26]
Sem alarme 24 horas: A zona NO criar um alarme. Pode ser utilizada com a funo de seguimento de zona para
aplicaes de automao
[29]
Incndio verificado automaticamente: Quando violado, o sistema reiniciar todos os detectores de fumos por 20 segundos e,
em seguida, aguardar 10 segundos para que os detectores fixem-se em seu estado. Se outro alarme de incndio for
detectado dentro de 60 segundos, a zona accionar o alarme imediatamente
[30]
Superviso: Alarme instantneo, o sistema activar o besouro do teclado. Um cdigo de utilizador vlido necessrio para
silenciar o besouro do teclado.
[31]
Zona diurna: Alarme instantneo quando o sistema est armado, cigarra do teclado (sem alarme) quando o sistema est
desarmado
[32]
Away/Stay instantneo: Similar ao Instantneo, excepto pelo fato de que a Central ir inibir automaticamente a zona se
armado no modo Stay
[35]
Sirene/Besouro 24 horas: Alarme instantneo quando violado, o sistema activar a sada da sirene quando armado, o
besouro do teclado quando desarmado
[36]
Zona sem travamento anti sabotagem 24 horas: Condio de sabotagem instantnea quando violado. Activa tanto no estado
armado quanto desarmado.
[37]
Zona nocturna: Funciona como o Interno, Stay/Away, mas permanecer inibido se o utilizador pressionar [][1] para
Reactivar as zonas Stay/Away quando armado no modo Stay
[41]
Deteco de monxido de carbono (CO) 24 horas. Esse tipo de zona utilizado com um detector de CO sem fio. Essa definio
de zona possui uma cadncia de campainha diferenciada em caso de alarme. A cadncia desse alarme 4 ciclos de pulsos de
ativao/desativao de 100 ms, seguido por uma pausa de 5 segundos e em seguida a cadncia repetida. Aps 4 minutos, a
pausa de 5 segundos estendida para 60 segundos de durao. A campainha ser silenciada quando um cdigo de acesso for
especificado ou quando o tempo da campainha se esgotar. Consulte o manual de detector de CO para informao adicionais.
[81]
Deteco de CO (sem fio) 24 horas. Esse tipo de zona utilizado com um detector de CO sem fio. Essa definio de zona
possui uma cadncia de campainha diferenciada em caso de alarme. A cadncia desse alarme 4 ciclos de pulsos de
ativao/desativao de 100 ms, seguido por uma pausa de 5 segundos e em seguida a cadncia repetida. Aps 4
minutos, a pausa de 5 segundos estendida para 60 segundos de durao. A campainha ser silenciada quando um cdigo
de acesso for especificado ou quando o tempo da campainha se esgotar.
[87]
Incndio com retardo 24 horas (sem fio/enderevel): O mesmo que Incndio com retardo 24 horas (com fio), mas deve ser
utilizado para detectores de fumos sem fio ou endereveis
[88]
Incndio padro 24 horas (sem fio/enderevel): O mesmo que Incndio padro 24 horas (com fio), mas deve ser utilizado
para detectores de fumos sem fio ou endereveis
12
[04]
[05]
[06]
[07]
[08]
[09]
[10]
[11]
[12]
[13]
[14]
[15]
[16]
[17]
[18]
[19]
[20]
[21]
[22]
[23]
[24]
[25]
[26]
[28]
[29]
[30]
[31]
[32]
[33]
[34]
Entrada silenciosa 24 horas: Muda a PGM para uma zona silenciosa 24 horas (somente PGM2).
Entrada audvel 24 horas: Muda a PGM para uma zona audvel 24 horas (somente PGM2).
Incndio e roubo com retardo: Funciona como uma sada de incndio e roubo, mas no ACTIVADA at que o tempo de
retardo da transmisso expire.
Sada de teste da bateria: A sada ACTIVADA por 10 segundos ao meio-dia de cada dia.
Sada de assalto: ACTIVADA quando ocorre um alarme de assalto (hold-up) em uma partio atribuda. Permanece activa
at que todas as parties atribudas sejam armadas ou desarmadas. No ser ACTIVADA se uma zona de assalto entrar
em uma condio de sabotagem ou falha.
Acompanhador de zona (Zonas 1-8): Activo quando uma das zonas Seleccionadas estiver activa, e desactiva quando todas
as zonas Seleccionadas forem restauradas.
Memria do alarme de estado da partio: ACTIVADA quando a partio Seleccionada estiver armada. A sada ir pulsar
um segundo a indicao ON / um segundo a indicao OFF quando ocorrer um alarme.
Comunicador alternativo: activado quando o evento do sistema Seleccionado ocorrer. Se for activado no estado armado,
permanecer activo at que o sistema seja desarmado. Se for activado no estado desarmado, permanecer activo at que
um cdigo de acesso vlido seja digitado dentro do tempo de interrupo da sirene, ou quando o sistema for armado depois
que o tempo de interrupo da sirene expirar.
Abrir aps alarme: ACTIVADA por cinco segundos quando o sistema desarmado aps um alarme.
Estado da sirene e sada de acesso programao: Activa-se quando o modo e programao do instalador, sirene ou DLS
est activo. Permanece activo at que a sirene no esteja mais activa, o modo de programao do instalador seja encerrado
e a programao DLS seja desconectada.
Armado no modo Away (Ausente) sem estado de zona inibida: Activa-se quando armado com zonas no modo Stay/Away
activas e nenhuma zona inibida.
13
PowerSeries - PC1616/PC1832/PC1864
[35]
Acompanhador de zona (Zonas 9-16): Activo quando uma das zonas Seleccionadas estiver activa, e desactiva quando todas as
[36]
Acompanhador de zona (Zonas 17-24): Activo quando uma das zonas Seleccionadas estiver activa, e desactiva quando todas as
[37]
Acompanhador de zona (Zonas 25-32): Activo quando uma das zonas Seleccionadas estiver activa, e desactiva quando todas as
[38]
Acompanhador de zona (Zonas 33-40): Activo quando uma das zonas Seleccionadas estiver activa, e desactiva quando todas as
[39]
Acompanhador de zona (Zonas 41-48): Activo quando uma das zonas Seleccionadas estiver activa, e desactiva quando todas as
[40]
Acompanhador de zona (Zonas 49-56): Activo quando uma das zonas Seleccionadas estiver activa, e desactiva quando todas as
[41]
Acompanhador de zona (Zonas 57-64): Activo quando uma das zonas Seleccionadas estiver activa, e desactiva quando todas as
[4]
[5]
[6]
[7]
[8]
ON (ACTIVADO): o sistema emite um rudo da sada da sirene uma vez quando a partio armada, duas vezes quando
desarmada. OFF (DESACTIVADO): a sada da sirene no ACTIVADA.
ON (ACTIVADO): o sistema emite um rudo da sada da sirene a cada 10 segundos durante o precavera de arme automtico.
OFF (DESACTIVADO): a sada da sirene no ACTIVADA.
ON (ACTIVADO): o sistema emitir um rudo da sada da sirene uma vez por segundo durante o retardo de sada, 3 rudos por
segundo nos ltimos 10 segundos. OFF (DESACTIVADO): a sada da sirene no ser ACTIVADA.
ON (ACTIVADO): o sistema emitir um rudo da sada da sirene uma vez por segundo durante o retardo de entrada, 3 rudos por
segundo nos ltimos 10 segundos. OFF (DESACTIVADO): a sada da sirene no ser ACTIVADA.
ON (ACTIVADO): o sistema emitir um rudo da sada da sirene uma vez a cada 10 segundos sob a presena de uma condio
de problema. OFF (DESACTIVADO): a sada da sirene no ACTIVADA.
ON (ACTIVADO): o sistema emitir bips nos teclados uma vez por segundo, e 3 trs vezes por segundo durante os ltimos 10
segundos, durante o retardo de sada quando o sistema for armado com um cdigo de utilizador ou armado no modo Away
(Ausente). OFF (DESACTIVADO): o teclado no emitir bips.
ON (ACTIVADO): o retardo de sada ser encerrado (reduzido a cinco segundos) quando a zona Retardo 1 for violada e restaurada aps o arme do sistema. OFF (DESACTIVADO): a contagem regressiva do retardo de sada ocorrer normalmente.
ON (ACTIVADO): a sada da sirene no ser interrompida se ocorrer um alarme de incndio. O utilizador dever DESACTIVAR
a sirene digitando um cdigo de utilizador vlido.
OFF (DESACTIVADO): a sada da sirene ser interrompida normalmente.
14
[5]
[6]
[7]
[8]
ON (ACTIVADO): o sistema supervisiona a entrada de CA e exibe um problema caso alguma falha seja detectada. OFF (DESACTIVADO): a entrada de CA no ser supervisionada.
ON (ACTIVADO): a luz de problema piscar quando um problema de CA for detectado. OFF (DESACTIVADO): a luz de problema acende, e no pisca.
ON (ACTIVADO): o teclado se apaga (no as luzes indicadores) se nenhuma tecla for pressionada em 30 segundos.
OFF (DESACTIVADO): o teclado no se apaga.
ON (ACTIVADO): um cdigo de utilizador vlido deve ser digitado para restaurar o funcionamento normal do teclado aps seu
apagamento. OFF (DESACTIVADO): pressionar qualquer tecla retorna o teclado ao funcionamento normal.
ON (ACTIVADO): a iluminao de fundo do teclado ACTIVADA. OFF (DESACTIVADO): a iluminao de fundo do teclado
DESACTIVADA.
ON (ACTIVADO): o sistema habilita temporariamente a funo de apagamento das luzes do teclado se uma falha de CA detectada (para preservar a bateria de emergncia). OFF (DESACTIVADO): o sistema funcionar normalmente.
ON (ACTIVADO): o teclado ACENDE a luz Bypass (Excluso) se as zonas forem inibidas enquanto o sistema estiver armado.
OFF (DESACTIVADO): a luz Bypass (Excluso) se APAGA quando o sistema for armado.
ON (ACTIVADO): o sistema supervisiona as violaes do teclado. OFF (DESACTIVADO): o sistema no supervisiona as violaes do teclado.
[2]
[3]
[4]
NOTA: Esta funo deve ser desabilitada para que esteja em conformidade com a norma DD243.
Esta uma extenso flexvel do Cdigo de polcia existente.
Esta funo diretamente afetada pelo Timer da zona de travessia.
[5]
[6]
[7]
[8]
ON (ACTIVADO): o sistema registra e comunica um evento Tarde para fechar quando armado automaticamente no tempo programado (so se o arme automtico tiver sido provocado pela funo de arme de no atividade).
OFF (DESACTIVADO): o sistema no transmite nem registra um evento Tarde para fechar.
ON (ACTIVADO): habilita a funo de ajuste automtico do relgio para o horrio de vero.
OFF (DESACTIVADO): o sistema no ajusta o relgio automaticamente para o horrio de vero.
Para uso futuro
ON (ACTIVADO): o sistema emitir o rudo da sada da sirene somente quando o sistema estiver armado no modo Ausente.
OFF (DESACTIVADO): o sistema emitir o rudo da sirene quando o sistema estiver armado em qualquer modo. Consulte a Seco [14].
15
PowerSeries - PC1616/PC1832/PC1864
[3]-[4]
[5]
[6]
[7]
[8]
ON (ACTIVADO): o sistema transmite um cdigo de transmisso de teste somente se nenhum outro evento for transmitido Central Receptora durante o tempo programado. OFF (DESACTIVADO): o sistema sempre transmite um cdigo de transmisso de
teste conforme o programado.
ON (ACTIVADO): Emisso de relatrios de excluso em tempo real habilitada. Quando [*][1] for utilizado para excluir uma zona
que no seja 24 horas, o sistema registrar as informaes imediatamente e comunicar o status de excluso da zona.
OFF (DESACTIVADO): Emisso de relatrios de excluso em tempo real desabilitada. Quando [*][1] for utilizado para excluir
uma zona que no seja 24 horas, o sistema registrar as informaes e comunicar o status de excluso da zona aps o arme da
partio. Os status de excluso de zonas de 24 horas sero imediatamente registrados e comunicados
Para uso futuro
ON (ACTIVADO): o besouro do teclado acompanha a sada da sirene para todos os alarmes.
OFF (DESACTIVADO): o sistema activa somente a sada da sirene para todos os alarmes.
ON (ACTIVADO): Quando um alarme detectado em uma zona (com o atributo do cruzamento de zona habilitado), um temporizador iniciado. O alarme no transmitido e a sada da sirene no ACTIVADA a menos que uma segunda zona de cruzamento de zona habilitada seja violada antes de o temporizador do cruzamento de zona expirar. OFF (DESACTIVADO): o sistema
transmite todos os alarmes normalmente e registra e transmite um cdigo policial se um alarme em uma segunda zona for detectado durante o perodo em que estiver armado.
ON (ACTIVADO): o sistema reinicia o retardo de sada (uma vez) se a zona de retardo for violada e restaurada durante o tempo
de retardo de sada. OFF (DESACTIVADO): o retardo de sada no reiniciado.
ON (ACTIVADO): o sistema activa os bips de problema quando um problema de CA detectado.
OFF (DESACTIVADO): o sistema no anuncia problemas de CA utilizando o besouro do teclado.
[2]
[3]
[4]
[5]
[6]
[7]
[8]
ON (ACTIVADO): a sirene ir tocar durante o perodo de tempo definido se ocorrer uma falha de uma zona via rdio
enquanto o sistema tiver armado.
OFF (DESACTIVADO): A falha de uma zona via rdio no ser indicada pelo tocar da sirene.
Para uso futuro
ON (ACTIVADO): Quando desarmar, o teclado exibir somente o primeiro alarme que ocorreu durante o ltimo perodo de
arme. OFF (DESACTIVADO): Quando desarmar, o teclado exibir todas as zonas que entraram em alarme durante o ltimo
perodo de arme.
Para uso futuro
ON (ACTIVADO): um problema na superviso de um mdulo ser indicado pelo tocar da sirene.
OFF (DESACTIVADO): um problema na superviso de um mdulo no activar o toque da sirene
ON (ACTIVADO): o indicador do LED verde nos teclados indica o estado de CA no sistema.
OFF (DESACTIVADO): o indicador de LED verde nos teclados indica o estado de partio pronta.
ON (ACTIVADO): Todos os cdigos de acesso de utilizador podem entrar no menu de funes do utilizador.
OFF (DESACTIVADO): Somente o cdigo de Utilizador Principal pode entrar no menu de funes do utilizador.
Para uso futuro
ON (ACTIVADO): Os cdigos de acesso no sero aceitos pelo sistema durante o retardo de entrada.
OFF (DESACTIVADO): Um cdigo de acesso pode ser utilizado para desarmar o sistema durante o retardo de entrada.
ON (ACTIVADO): Procedimento de Entrada EU (esta funo s ser ativada quando a partio estiver armada). Se uma violao de zona ocorrer porm o retardo de entrada no estiver ativado, a sirene ir soar e o alarme ser comunicado imediatamente, dependendo do tipo de zona acionada. Quando o retardo da entrada estiver ativado, todos os alarmes de zona do tipo
roubo que ocorrerem iro acionar a sirene porm no sero comunicados. Todos os alarmes do tipo intruso que ocorrerem
durante o retardo de entrada sero considerados alarmes falsos, com exceo do modo Incndio. Quando o retardo de
entrada expirar, o painel retarda a comunicao do alarme durante 30 segundos a mais para permitir que o usurio tenha
tempo de desarmar. O temporizador do cdigo de polcia no ser iniciado at que o retardo de transmisso de 30 segundos
tenha expirado sem um procedimento de desarme vlido. O cdigo de polcia no gerado como resultado de alarmes gerados durante o retardo de entrada, embora o temporizador do cdigo de polcia seja iniciado quando o retardo de entrada e o
retardo de comunicao de 30 segundos expirarem. Se o temporizador do cdigo de polcia j estiver ativo quando o retardo
de entrada for iniciado, as zonas de intruso violadas no sero contadas como eventos de cdigo de polcia. Aps o retardo
de entrada e a extenso de 30 segundos expirar, a violao de uma zona de roubo (zona do tipo no-entrada) gerar um
cdigo de polcia.
Se o temporizador do cdigo de polcia expirar durante o retardo de entrada ou a extenso de 30 segundos, o temporizador
ser interrompido at que estes perodos tenham-se esgotado. O contador ser ento reinicializado. Um novo alarme de roubo
dever ocorrer aps o retardo de entrada e a extenso do retardo de transmisso de 30 segundos antes que o cdigo de polcia seja gerado. Os alarmes ocorridos durante o retardo de entrada no resultam na gerao de um cdigo de polcia.
Os alarmes de tipo de zona a seguir iro ativar a sirene e iro retardar as comunicaes para a estao de monitoramento se
a violao da zona ocorrer enquanto o retardo de entrada estiver ativo na partio: Instantneo, Interna, Presente/Ausente
16
Interna, Presente/Ausente com Retardo, Supervisor 24 horas, Cigarra 24 Horas, Roubo 24 Horas, Emergncia 24 Horas,
gua 24 Horas, Congelamento 24 Horas, Retardo Interno, Zona Diria, Presente/Ausente Instantneo, Zona Noturna.
NOTA: O procedimento de entrada EU tem prioridade sobre a operao do retardo de campainha ou retardo de transmisso. Se um
alarme ocorrer em uma zona de roubo 24 Horas quando o retardo de entrada NO estiver ativo, as funes de retardo da campainha ou
retardo de transmisso iro operar normalmente. Se um alarme ocorrer durante o retardo de entrada quando esta funo estiver habilitada, a campainha ir soar imediatamente e a transmisso do alarme ser suprimida durante o tempo de retardo de entrada remanescente
mais 30 segundos.
OFF (DESACTIVADO): Procedimento de Entrada Padro. Os alarmes de roubo que ocorrerem durante o retardo de entrada
ativaro a sirene. Se o temporizador de retardo da campainha estiver programado, um alarme da zona do tipo roubo seguir
o temporizador de retardo da campainha independentemente se o retardo de entrada estiver ativado. Quando esta funo
estiver desativada, os alarmes de roubo que ocorrerem durante o retardo de entrada sero comunicados imediatamente.
Contudo, se o retardo da transmisso estiver habilitado, um alarme de uma zona com o atributo de retardo de transmisso
habilitado ser retardado independentemente se o retardo de entrada estiver ativado.
[3]-[5] Para uso futuro
[6]
ON (ACTIVADO): Chaves de teclado e teclas sem fio podem desarmar o sistema somente durante um retardo de entrada.
OFF (DESACTIVADO): As chaves de teclado e teclas sem fio podem desarmar o sistema independentemente se o retardo
de entrada estiver activo ou no.
[7]
ON (ACTIVADO): Programao do Instalador acessvel apenas quando a janela DLS estiver aberta.
OFF (DESACTIVADO): Programao do Instalador acessvel a qualquer momento.
[8]
ON (ACTIVADO): O Armar ser inibido at que as condies de problemas tenham sido restauradas.
OFF (DESACTIVADO):O sistema pode ser Armado com condies de problema presentes.
[7]
[8]
ON (ACTIVADO): Um cdigo de acesso necessrio para aceder os menus [][1], [][2], [][3].
OFF (DESACTIVADO): Nenhum cdigo de acesso necessrio para aceder os menus [][1], [][2], [][3].
ON (ACTIVADO): Quando o sistema Armar, o teclado ir ficar em branco aps o tempo programado expirar.
OFF (DESACTIVADO): Aps o Armar, o teclado no ir ficar em branco.
Para uso futuro
ON (ACTIVADO): Somente o cdigo de Utilizador Principal pode ser utilizado para inibir uma zona de assalto.
OFF (DESACTIVADO): Qualquer cdigo de acesso vlido pode inibir uma zona de assalto.
ON (ACTIVADO): As sadas PGM tipo 5, 6, 17 e 18 sero desactivadas se o teclado ficar em branco.
OFF (DESACTIVADO): As sadas no sero desactivadas.
ON (ACTIVADO): Delinquncia Sem Fio Desabilitada. Problemas de Delinquncia no Dispositivo RF no so gerados.
OFF (DESACTIVADO): Delinquncia Sem Fio Habilitada. Se uma transmisso de superviso sem fio no for recebida de
todas as zonas sem fio, teclados e sirenes durante um perodo de 12 minutos, o sistema ir entrar no modo No Pronto para
Armar. O LED de Prontido ser desativado e o LED de Problema ser ativado. O painel ir gerar um problema silencioso
(nenhum bip de problema, porm com o LED de Problema ativado) denominado Delinquncia no Dispositivo RF visualizado
em [][2][5]. O usurio pode ignorar esta condio para armar o painel..
ON (ACTIVADO): Aps o tempo de sada expirar, o Armar ser cancelado se uma zona estiver aberta.
OFF (DESACTIVADO): Aps o tempo de sada expirar, o Armar ser executado, mesmo se uma zona estiver aberta.
ON (ACTIVADO): Quando o sistema estiver armado no modo Stay (Presente), durante o retardo de sada, o sistema emitir
um bip a cada trs segundos. OFF (DESACTIVADO): Quando o sistema estiver armado no modo Stay (Presente), o sistema
permanecer silencioso durante o retardo de sada.
ON (ACTIVADO): a tecla de emergncia [F] do teclado emitir um bip trs vezes para informar que a tecla foi pressionada. O
sistema no activar a sada da sirene. OFF (DESACTIVADO): o sistema activar a sada da sirene e o bip do teclado.
Para uso futuro.
ON (ACTIVADO): o sistema ir transmitir o cdigo de transmisso de teste somente se o sistema for armado na hora em que
o sistema estiver programado para transmitir o evento.
OFF (DESACTIVADO): o sistema sempre transmitir o cdigo de transmisso de teste na hora programada.
ON (ACTIVADO): o sistema mudar o tempo do ciclo de transmisso de teste de dias para horas.
OFF (DESACTIVADO): o tempo do ciclo de transmisso de teste ser em dias.
ON (ACTIVADO): o utilizador no pode mudar do modo armado em Away (Ausente) para armado no modo Stay (Presente)
utilizando as teclas de funo. OFF (DESACTIVADO): o utilizador pode mudar os modos de armar.
ON (ACTIVADO): o sistema desliga uma sesso de escuta/duas vias se ocorrer um novo evento.
OFF (DESACTIVADO): o sistema NO desligar. Novos eventos sero transmitidos somente depois que a sesso for encerrada.
ON (ACTIVADO): o sistema NO activa o besouro do teclado para qualquer condio de problema (excepto problemas de
incndio). OFF (DESACTIVADO): o sistema anuncia problemas atravs do besouro do teclado (dois bips a cada 10 segundos) normalmente.
Para uso futuro.
17
PowerSeries - PC1616/PC1832/PC1864
18
Os dados [000] indicam que o dia do ms que ser programado na Seco Dia abaixo. Os dados de [001] a [005] representam as semanas de 1 a 5 do ms. A semana 5 sempre representa a ltima semana do ms, independentemente do
nmero de semanas do ms.
Dia
Os dados de [001] a [031] representam o dia do ms se [000] for programado na Seco da semana acima. Se [001] a
[005] for programado na Seco semana acima, os dados de [000] a [006] representaro domingo a sbado.
Hora
Os dados [000] ou [023] representam a hora em que o horrio padro entrar em vigor.
Incremento Os dados [001] ou [002] representam o nmero de horas para atrasar o relgio para o horrio padro.
Semana
19
PowerSeries - PC1616/PC1832/PC1864
Todas as sees de nmeros de telefone so de 32 dgitos de extenso. Os dgitos hexadecimais podem ser programados no
nmero de telefone para executar funes adicionais como segue:
Digite [][2][] HEX B para discar
Digite [][3][] HEX C para discar #
Digite [][4][] HEX D para uma busca de tons de discagem adicionais, conforme necessrio para sistemas de telefonia
PABX.
Digite [][5][] HEX E para inserir uma pausa de 2 segundos no nmero de telefone.
NOTA: Haver uma pausa automtica de 2 segundos antes que as buscas de tom de discagem adicionais sejam iniciadas.
HEX A no utilizada.
HEX F representa o trmino do nmero de telefone (qualquer caractere aps F ser ignorado)
Se [#] for pressionada nessas sees, o sistema ir sair e salvar todo o nmero de telefone. O painel no tentar realizar a
comunicao se nenhum nmero de telefone for programado. Isso se aplica aos nmeros de telefone 1 e 2.
20
ria fraca sem fio para a estao central. Entradas vlidas: [000] a [255]. Programe os dados [000] para no haver retardo.
Retardo da transmisso de delinquncia: Nmero de horas (actividade de delinquncia) ou dias (arme de delinquncia) em que a Cen-
tral retardar a transmisso do evento para a Central Receptora. Entradas vlidas: [001] a [255].
Janela de cancelamento da comunicao: O tempo, em segundos, aps a ocorrncia de um alarme que o sistema transmitir um
evento de cancelamento de comunicao se o sistema for desarmado. O teclado emitir um bip rpido para indicar que o evento de
cancelamento de comunicao foi transmitido com sucesso. Entradas vlidas: [001] a [255].
21
PowerSeries - PC1616/PC1832/PC1864
Descrio
ON (ACTIVADO): o teclado emite bips oito vezes aps a transmisso bem sucedida do evento de abertura aps alarme.
OFF (DESACTIVADO): o teclado no emitir bips.
ON (ACTIVADO): a sada da sirene emite rudos oito vezes aps a transmisso bem sucedida do evento de abertura aps alarme. OFF
(DESACTIVADO): a sada da sirene no ACTIVADA.
ON (ACTIVADO): o sistema utiliza cdigos de transmisso programados na transmisso utilizando o formato SIA.
OFF (DESACTIVADO): o sistema gera automaticamente todos os cdigos transmitidos.
ON (ACTIVADO): o sistema emite bips do teclado oito vezes aps a transmisso bem sucedida de um evento de fechamento.
OFF (DESACTIVADO): o teclado no emitir bips.
ON (ACTIVADO): o sistema solicita uma sesso de escuta/duas vias na prxima vez que chamar o 1/3 nmero de telefone quando o
PC59xx transmitir uma solicitao.
OFF (DESACTIVADO): o sistema ignora a solicitao do PC59xx. Esta opo utilizada em mdulos da srie PC59xx.
ON (ACTIVADO): o sistema solicita uma sesso de escuta/duas vias na prxima vez que chamar o 2 nmero de telefone quando o
PC59xx transmitir uma solicitao.
OFF (DESACTIVADO): o sistema ir ignorar a solicitao do PC59xx. Esta opo utilizada em mdulos da srie PC59xx.
ON (ACTIVADO): o sistema utiliza cdigos de transmisso programados no formato Contact ID para transmitir cdigos.
ON (ACTIVADO): o sistema utilizar o dgito [5] como o primeiro dgito do cdigo de transmisso de fechamento parcial na transmisso
de cdigos no formato Contact ID (ID de contacto). OFF (DESACTIVADO): o sistema utilizar o dgito [4] como o primeiro dgito do
cdigo de transmisso de fechamento parcial na transmisso de cdigos no formato Contact ID (ID de contacto).
ON (ACTIVADO): o sistema transmitir todos os alarmes durante o teste de caminhada.
OFF (DESACTIVADO): o sistema no transmitir eventos de alarme durante o teste de caminhada.
ON (ACTIVADO): o teclado exibir a mensagem Communications Cancelled (Comunicao cancelada) (LCD programvel) ou "CC"
(LCD de mensagens fixas) aps a transmisso bem sucedida do evento de comunicao cancelada.
OFF (DESACTIVADO): o teclado no exibir essas mensagens.
ON (ACTIVADO): o sistema disca a sequncia de cancelamento de chamada em espera na primeira tentativa de chamada para a Central Receptora. OFF (DESACTIVADO): o sistema no disca a sequncia de cancelamento de chamada em espera.
ON (ACTIVADO): habilita o suporte para o mdulo TL/GS. OFF (DESACTIVADO): desabilita o TL/GS.
ON (ACTIVADO): o temporizador do retardo de transmisso de falha CA utilizar horas.
OFF (DESACTIVADO): o retardo ser em minutos.
ON (ACTIVADO): Define o nmero de tentativas de chamada para 1 quando utilizar o formato de chamada residencial.
OFF (DESACTIVADO): A chamada residencial acompanha o contador de tentativas de chamada.
Para uso futuro
ON (ACTIVADO): Eventos programados para comunicar o n. de telefone 1 utilizaro o nmero da conta da partio da Seco [311].
Eventos programados para comunicar o n. de telefone 2 utilizaro o nmero da conta da partio da Seco [312].
OFF (DESACTIVADO): Cada evento utilizar o cdigo de conta de sua respectiva partio.
[2-8]
ON (ACTIVADO): o sistema atender as chamadas de entrada para download (nmero de toques programados ou chamada dupla).
OFF (DESACTIVADO): o sistema no atende as chamadas recebidas utilizando a rotina de chamada dupla para download.
Essas configuraes no afectam a janela de download DLS de seis horas na activao.
[2]
ON (ACTIVADO): o utilizador pode habilitar o download para a janela DLS utilizando o comando [][6]. OFF (DESACTIVADO): o utili[3]
[4]
[5]
[6]-[8]
HEX [A]
HEX [B]
HEX [C]
HEX [D]
HEX [E]
HEX [F]
No utilizado
Simula o pressionar da tecla []
Simula o pressionar da tecla [#]
Busca do tom de chamada adicional
Pausa de dois segundos
Final do marcador do nmero de telefone
23
PowerSeries - PC1616/PC1832/PC1864
Opo de sada PGM [01], [03] a [08], [11] a [22], [25],[26], [28], [30], [33], [34]
Opo Descrio
[3]
ON (ACTIVADO): a sada PGM funcionar normalmente (muda para Teraa quando ACTIVADA). OFF (DESACTIVADO): a
sada PGM ser aterrada normalmente e mudar para colector aberto (circuito aberto) quando ACTIVADA.
ON (ACTIVADO): a sada PGM ser ACTIVADA na durao do temporizador de sada PGM quando o comando [][7][x] for
executado. OFF (DESACTIVADO): a sada PGM ficar travada at que o comando [][7][x] seja executado novamente.
ON (ACTIVADO): um cdigo de utilizador vlido dever ser digitado aps o comando [][7][x].
OFF (DESACTIVADO): o cdigo de utilizador no necessrio.
ON (ACTIVADO): a sada PGM ACTIVADA na presena de uma condio de problema de servio necessrio.
[2]
[3]
[4]
[5]
[6]
[7]
[8]
24
ON (ACTIVADO): configura o sistema para CA de 50 Hz. OFF (DESACTIVADO): configura o sistema para CA de 60 Hz.
ON (ACTIVADO): o sistema utiliza o cristal interno para o relgio da Central interno. OFF (DESACTIVADO): o sistema utiliza a frequncia de CA para o relgio interno da Central.
ON (ACTIVADO): o sistema inibir o arme na presena de uma condio de problema de CA ou de bateria fraca. OFF (DESACTIVADO): o arme no ser inibido.
ON (ACTIVADO): todos os problemas de violao sero travados e o arme ser inibido. Entre na programao do instalador para apagar a condio de problema e retornar operao normal. OFF (DESACTIVADO): os problemas de violao no sero parados e no
inibiro o armar.
ON (ACTIVADO): todos os cdigos de acesso possuem seis dgitos. OFF (DESACTIVADO): todos os cdigos de acesso possuem
quatro dgitos.
ON (ACTIVADO): o sistema desligar se um tom de ocupado for detectado. Essa tentativa no ser contada como parte das tentativas
mximas de chamada programadas. OFF (DESACTIVADO): a Central no detectar tons de ocupado.
ON (ACTIVADO): o sistema carregar a bateria a aproximadamente 700mA. DESACTIVADO: o sistema carregar a bateria a 400 mA.
ON (ACTIVADO): o sistema cancelar uma sesso DLS, um acesso ao Escort, uma sesso de escuta/duas vias se ocorrer um evento
de comunicao com a Central Receptora. OFF (DESACTIVADO): eventos no crticos (transmisso de teste, teste peridico e teste do
sistema) no cancelaro a sesso. Os eventos sero comunicados aps a concluso da sesso.
25
PowerSeries - PC1616/PC1832/PC1864
[6]
[7]
[8]
Programao de modelos para obter uma descrio detalhada dos modelos disponveis e os cdigos de 5 dgitos correspondentes.
Aps digitar um cdigo de programao de 5 dgitos vlido, voc ser solicitado a digitar o seguinte na sequncia abaixo:
5. Retardo de entrada 1 da partio 1, Retardo de sada da partio 1, digite o tempo de retardo com trs dgitos
Programe o retardo de entrada desejado da partio 1 com trs dgitos (em segundos) seguido pelo retardo de sada desejado da
partio 1 (em segundos). Pressione [#] para completar sua entrada. Esses valores sero inseridos na Seco de programao
[005], subSeco [01], entradas 1 e 3 respectivamente.
6. Cdigo do instalador
Digite o cdigo de acesso do instalador com quatro ou seis dgitos (que depende da Seco [701], opo 5). Pressione [#] para
completar sua entrada. Esse cdigo de acesso do instalador ser inserido na Seco de programao [006].
Aps programar o cdigo do instalador, o teclado retornar ao menu base de programao do instalador.
NOTA: Todas as informaes de programao de modelos devem ser inseridas novamente aps a restaurao das configuraes
padro do hardware ou software.
26
Luz do indicador
(zona)
[01] to [08]
[09] to [14]
[15]
[16]
[17]
[18]
Mdulo
Luz do indicador
(zona)
[19]
[20]
[21]
[22]
[24]
[26] to [29]
Mdulo
Mdulo PC5204
Mdulo PC5400
Mdulo PC59xx
Comunicador alternativo
Escort5580 ou Escort5580TC
PC5200 N.o 1 a N.o 4
27
PowerSeries - PC1616/PC1832/PC1864
[<]
[>]
[*]
[#]
[0]
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
[9]
Exemplo:
Pressione a tecla "2" 3 vezes para inserir a letra F.
Pressione a tecla "2" 4 vezes para inserir o nmero 2.
4. Pressione [*] para acessar as opes de programao de
as identificaes.
Pressione [*] para selecionar a opo.
WORDS
SALVAR - Salva a nova identificao. Se esta funo no for selecionada antes de fechar a seo de programao de identifica-
(a, b, c).
INSERO ASCII - Esta opo se destina insero de caracteres incomuns, ou como um mtodo primrio para a programao
de identificaes. Inseres de 255 caracteres esto disponveis, embora algumas inseres sejam duplicadas. Utilize as teclas
[<][>] para rolar atravs dos caracteres ou inserir um nmero de 3 dgitos de 000-255. Pressione a tecla [*] para inserir um caractere na identificao.
CLEAR TO END (APAGAR AT O FIM) - Esta opo apaga os caracteres do visor desde o ponto do cursor at a extremidade do
visor.
CLEAR DISPLAY (APAGAR TELA) - Esta opo ajusta todos os caracteres em uma identificao para "espaio" ou apagado.
Biblioteca de identificaes
A Biblioteca de identificaes um banco de dados de palavras comumente usadas quando da programao de identificaes. Palavras individuais podem ser combinadas conforme a necessidade. por exemplo, Porta + Frontal. Cada linha do visor suporta uma exibio de no mximo 14 caracteres. Se uma palavra no se encaixar em uma linha, role o cursor para a direita at que o mesmo aparea
no primeiro caractere da segunda linha, em seguida, adicione a palavra.
Para programar uma identificao personalizada usando a Biblioteca de identificaes:
1. Acesse a programao do teclado e selecione a identificao a ser trocada. por exemplo, [][8] [Cdigo do Instalador][][001]
(para programar a identificao para a zona 01).
2. Pressione [] para abrir o menu "Select Options" (Selecionar opes)
3. Pressione [] novamente para selecionar a opo, insero de palavra).
4. Digite o nmero de 3 dgitos correspondentes a uma palavra (ver a Tabela de Insero de palavras abaixo) ou use as teclas de
rolagem [<][>] para visualizar palavras na biblioteca.
5. Pressione [] para selecionar a palavra.
6. Para adicionar mais uma palavra, repita o procedimento acima a partir do passo 2.
7. Para adicionar um espao, pressione a tecla de rolagem direita [>].
8. Para excluir caracteres, selecione "Clear to End" (Apagar at o final) ou "Display Clear" (Apagar tudo que est sendo exibido) a
partir do menu "Select Options" (Selecionar opes).
9. Para salvar a identificao atual, pressione [] para acessar o menu "Select Options" (Selecionar opes), role o cursor para a
esquerda [<] para "Save" (Salvar) e pressione [] novamente.
28
Palavras
#
001
002
003
004
005
006
007
008
009
010
011
012
013
014
015
016
017
018
019
020
021
022
023
024
025
026
027
028
029
030
031
032
033
034
035
036
037
038
039
040
041
042
Palavra
Abertura
Abortado
Abrir
Academia
Acender
Acesso
Acima
Adeus
Agora
Ajuda
Alarme
Alimentao
Alto
AM
Andar
Animal
rea
Armado
Armando
Armar
Armrio
Atividade
Ativo
Atrs
Ausente
Auxiliar
Baixo
Banheiro
Barra
Bateria
Beb
Biblioteca
Bnus
Bus
CA
Calor
Cancelado
Capacho
Caracterstica
Carbono
Carga
Carregando
#
043
044
045
046
047
048
049
050
051
052
053
054
055
056
057
058
059
060
061
062
063
064
065
066
067
068
069
070
071
072
073
074
075
076
077
078
079
080
081
082
083
084
Palavra
Carro
Casa
Central
Cerca
Chave
Choque
Coao
Cdigo
Computador
Comunicador
Congelar
Controle
Corrente
Corta
Corte
Cozinha
Crianas
Da
Da me
Da filha
Das
Data
De
Dentro
Desarmado
Descanso
Desligado
Deslizar
Desviado
Desviar
Desvio
Detector
Direita
Do
Do filho
Do pai
Domestico
Dos
Download
Duto
Economia
Edifcio
#
085
086
087
088
089
090
091
092
093
094
095
096
097
098
099
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
Palavra
Em
Energia
Entrada
Entrar
Erro
Escadas
Escritrio
Especial
Esquerda
Est
Estar
Exerccio
Exterior
Fbrica
Falha
Famlia
Favor
Fechado
Fechando
Fora
Forno
Frente
Fumaa
Fundo
Galeria
Garagem
Gs
Gaveta
Graus
Guarda-roupa
Hall
Hora
Horrio
Incndio
Inferior
Instalar
Interior
Invlido
Invaso
Janela
Jantar
Lar
#
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
29
Palavra
Lateral
Lavanderia
Leste
Ligado
Loja
Luzes
Master
Medico
Memria
Menu
Mesa
Monxido
Movimento
No
Nvel
Norte
Nmero
Oeste
OK
Ol
Panico
Para
Partio
Passarela
Ptio
Permanecer
Piscina
PM
Polcia
Por
Poro
Porta
Pressionar
Primeiro
Principal
Problema
Programa
Progresso
Quarto
Receptor
Relatrio
Reservada
#
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
Palavra
Retardo
RF
Sada
Sala
Segundo
Seguro
Sensor
Servio
Silencioso
Sirene
Sistema
Soar
Sol
Som
Sto
Sul
Superviso
Ttil
Teclado
Tela
Telefone
Temperatura
Teste
Todos
Traseiro
Unidade
Varanda
Vidro
Violao
Zona
0
1
2
3
4
5
6
7
8
9
A
B
#
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
Palavra
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
X
Y
Z
(Espao)
(Apstrofe)
- (Hfen)
_(Underline)
*
#
:
/
?
PowerSeries - PC1616/PC1832/PC1864
Pgina
Opo de programao
Pgina
[375] Direcionamento de chamadas do comunicador de manuteno do
sistema . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
[376] Direcionamento de chamadas do comunicador de transmisses
de teste do sistema . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
[377] Variveis de comunicao . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
[378] Horrio do dia de transmisso do teste . . . . . . . . . . . . . . . . . . . . . . . . . . 47
[379] Horrio do dia do DLS peridico . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
[380] Opes do 1 comunicador . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
[381] Opes do 2 comunicador . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
[382] Opes do 3 comunicador . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
[383] Opes do 4 comunicador . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
[401] Cdigos de opo de download do DLS . . . . . . . . . . . . . . . . . . . . . . . . . 48
[402] Nmero de telefone para download do DLS . . . . . . . . . . . . . . . . . . . . . . 48
[403]-[404] Cdigo de acesso para download do DLS/ Cdigo de
identificao da Central. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
[405] Temporizador de chamada dupla da secretria eletrnica . . . . . . . . . . . . 48
[406] Nmero de toques para atender . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
[499] Incio do download do PC-Link. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
[501]-[502] Atributos das sadas PGM 1 e 2 (Central principal) . . . . . . . . . . . 49
[503]-[504] Atributos das sadas PGM 3 e 4 (Central principal/PC5208) . . . . 49
[505]-[510] Atributos das sadas PGM 5-10 (5208) . . . . . . . . . . . . . . . . . . . . . 49
[511]-[514] Atributos das sadas PGM 11-14 (5204) . . . . . . . . . . . . . . . . . . . . 49
[551]-[552] Atribuio de parties s sadas PGM 1 e 2. . . . . . . . . . . . . . . . . 49
[553]-[554] Atribuio de parties s sadas PGM 3 e 4. . . . . . . . . . . . . . . . . 49
[555]-[560] Atribuio de parties s sadas PGM 5-10 (5208) . . . . . . . . . . . 50
[561]-[564] Atribuio de parties s sadas PGM 11-14 (5204) . . . . . . . . . . 50
[601]-[604] Cdigos de transmisso de fechamento (arme) . . . . . . . . . . . . . . . 51
[605]-[608] Cdigos de transmisso de abertura (desarme) . . . . . . . . . . . . . . . 52
[681]-[688] Programao do desarme automtico . . . . . . . . . . . . . . . . . . . . . . 52
[691]-[698] Programao de feriados para desarme automtico. . . . . . . . . . . . 52
[700] Ajuste automtico do relgio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
[701] Primeiras opes internacionais. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
[702] Segundas opes internacionais. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
[703] Retardo entre as tentativas de chamada . . . . . . . . . . . . . . . . . . . . . . . . . . 53
[801] Programao do mdulo de impresso PC5400 . . . . . . . . . . . . . . . . . . . 54
[802] Programao VOX PC59xx. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
[803] Programao do comunicador alternativo . . . . . . . . . . . . . . . . . . . . . . . . 54
[804] Programao de expanso sem fio RF5132. . . . . . . . . . . . . . . . . . . . . . . 54
[805] Programao PC5100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
[851] Programao TL/GS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
[898] Registo sem fio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
[899] Programao de modelos . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
[900] Exibio da verso da Central . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
[901] Habilitao/Desabilitao do modo de teste de caminhada
do instalador . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
[902] Restaurao da superviso do mdulo. . . . . . . . . . . . . . . . . . . . . . . . . . . 54
[903] Campo de superviso do mdulo. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
[904] Teste de localizao do mdulo sem fio . . . . . . . . . . . . . . . . . . . . . . . . . 54
[989] Reinicializao do Cdigo de Utilizador Principal para o padro. . . . . . 54
[990] Habilitao do bloqueio do instalador . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
[991] Desabilitao do bloqueio do instalador . . . . . . . . . . . . . . . . . . . . . . . . . 54
[993] Restaurao da programao padro do comunicador alternativo . . . . . 54
[995] Restaurao da programao padro do Escort5580 . . . . . . . . . . . . . . . . 54
[996] Restaurao da programao padro do RF5132/TR5164 . . . . . . . . . . . 54
[997] Restaurao da programao padro do PC5400 . . . . . . . . . . . . . . . . . . 54
[998] Restaurao da programao padro do PC59xx . . . . . . . . . . . . . . . . . . 54
[999] Restaurao da programao padro da Central de controlo. . . . . . . . . . 54
30
Partio/
Slot
[20] Zona
Atribuida
Tecla 1
Tecla 2
Tecla 3
Tecla 4
Tecla 5
11
00
03
04
06
14
16
18
00
03
04
06
14
16
TECLADO 1
00
TECLADO 2
00
TECLADO 3
00
TECLADO 4
00
TECLADO 5
00
TECLADO 6
00
TECLADO 7
00
TECLADO 8
00
13 Gs 24 horas*
01 Retardo 1*
14 Aquecimento 24 horas*
30 Superviso de incndio
02 Retardo 2*
15 Auxiliar 24 horas*
31 Zona diurna*
03 Instantneo*
16 Pnico 24 horas*
32 Away/Stay instantneo*
04 Interno*
17 Emergncia 24 horas*
35 Sirene/Cigarra 24 horas
05 Interno Presente/Ausente*
06 Retardo, Presente/Ausente*
19 gua 24 horas*
37 Zona noturna
20 Congelamento 24 horas*
09 Superviso 24 horas*
11 Roubo 24 horas*
25 Retardo interno*
31
PowerSeries - PC1616/PC1832/PC1864
Seo
[001]
Zona
01
Pad.
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
03
03
03
04
04
04
04
00
00
00
00
00
00
00
00
Seo
I_____I_____I
[002]
I_____I_____I
I_____I_____I
I_____I_____I
I_____I_____I
I_____I_____I
I_____I_____I
I_____I_____I
I_____I_____I
I_____I_____I
I_____I_____I
I_____I_____I
I_____I_____I
I_____I_____I
I_____I_____I
I_____I_____I
Zona
17
Pad.
00
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
Seo
I_____I_____I
[003]
I_____I_____I
I_____I_____I
I_____I_____I
I_____I_____I
I_____I_____I
I_____I_____I
I_____I_____I
I_____I_____I
I_____I_____I
I_____I_____I
I_____I_____I
I_____I_____I
I_____I_____I
I_____I_____I
I_____I_____I
Zona
33
Pad.
00
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
Seo
I_____I_____I
[004]
I_____I_____I
I_____I_____I
I_____I_____I
I_____I_____I
I_____I_____I
I_____I_____I
I_____I_____I
I_____I_____I
I_____I_____I
I_____I_____I
I_____I_____I
I_____I_____I
I_____I_____I
I_____I_____I
I_____I_____I
Zona
49
Pad.
00
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
I_____I_____I
I_____I_____I
I_____I_____I
I_____I_____I
I_____I_____I
I_____I_____I
I_____I_____I
I_____I_____I
I_____I_____I
I_____I_____I
I_____I_____I
I_____I_____I
I_____I_____I
I_____I_____I
I_____I_____I
I_____I_____I
030
045
120
I___I___I___I
I___I___I___I
I___I___I___I
030
045
120
Retardo de entrada 1
Retardo de entrada 2
Retardo de sada
030
045
120
I___I___I___I
I___I___I___I
I___I___I___I
I___I___I___I
I___I___I___I
I___I___I___I
030
045
120
I___I___I___I
I___I___I___I
I___I___I___I
I___I___I___I
I___I___I___I
I___I___I___I
Retardo de entrada 1
Retardo de entrada 2
Retardo de sada
030
045
120
Retardo de entrada 1
Retardo de entrada 2
Retardo de sada
030
045
120
Retardo de entrada 1
Retardo de entrada 2
Retardo de sada
Retardo de entrada 1
Retardo de entrada 2
Retardo de sada
030
045
120
I___I___I___I
I___I___I___I
I___I___I___I
I___I___I___I
I___I___I___I
I___I___I___I
Retardo de entrada 1
Retardo de entrada 2
Retardo de sada
030
045
120
Retardo de entrada 1
Retardo de entrada 2
Retardo de sada
I___I___I___I
I___I___I___I
I___I___I___I
Retardo de entrada 1
Retardo de entrada 2
Retardo de sada
004
I___I___I___I
NOTA: Retardo de entrada deve ser 45 segundos ou mais para sistemas complacente com padres EN50131-1/TS50131-3.
I_______I_______I_______I_______I
I_______I_______I_______I_______I
NOTA: Os tipos de sada [03], [04] e [20] no podem ser utilizados em conjunto no mesmo sistema.
32
19
Padro
I_________I_________I
PGM 1
10
I_________I_________I
PGM 2
Padro
01
I_________I_________I
01
I_________I_________I
01
I_________I_________I
01
I_________I_________I
01
I_________I_________I
01
I_________I_________I
01
I_________I_________I
01
I_________I_________I
PGM 7 (PC5208)
PGM 8 (PC5208)
PGM 9 (PC5208)
PGM 10 (PC5208)
NOTA: Essas duas seces permitem programar as sadas PGM3 e PGM4 na Central principal, e as duas primeiras sadas PGM no
PC5208. Se utilizar tanto as sadas da Central principal quanto as sadas do PC5208, a sada PGM3 funcionar da mesma forma que a
primeira sada do PC5208, e a sada PGM4 funcionar da mesma forma que a segunda sada do PC5208.
Padro
01
I_________I_________I
01
I_________I_________I
PGM 11
PGM 12
01
I_________I_________I
01
I_________I_________I
PGM 13
PGM 14
4
5
6
7
Desactivada
o do instalador
Falha de uma sada audvel habilitada
estiver armado
down
Sinal de incndio pulsado padro
4
5
7
8
tico
Desactivada
33
PowerSeries - PC1616/PC1832/PC1864
Padro
Activada
Desactivada
TLM habilitado
TLM Desabilitado
Problemas TLM emitir bips quando sistema armado
Padro
Activada
Desactivada
Desactivada
Desactivada
Emisso de relatrios de excluso em tempo real habilitada. Emisso de relatrios de excluso em tempo real desabilitada
34
Padro Activada
Desactivada
Indicao de pronto
00
00
00
00
00
00
00
I________I_______I
I________I_______I
I________I_______I
I________I_______I
I________I_______I
I________I_______I
I________I_______I
Padro Activada
Desactivada
Padro Activada
Desactivada
Delinquncia RF habilitada
Delinquncia RF desabilitada
35
PowerSeries - PC1616/PC1832/PC1864
Padro Activada
Desactivada
Padro Activada
Desactivada
Audvel
Silencioso
Fixo
Pulsado
N
Y
Y
Y
Y
Y
Y
Y
Y
N
N
Y
N
Y
Y
Y
Y
Y
Y
Y
Y
Y
N
N
Y
N
Y
N
Y
Y
Y
N
N
Y
Y
Y
Y
Y
Y
N
N
Y
Y
Y
Y
N
N
Y
Y
Y
Y
Y
Y
Y
N
N
Y
N
N
N
Y
Y
Y
Y
N
Y
Y
Y
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
Y
Y
Y
N
N
N
Forado
No
Impulso
No
N
Y
Y
Y
Y
Y
Y
N
N
N
Y
Y
N
N
N
N
N
N
N
N
N
N
N
N
Y
N
N
N
Y
Y
Y
N
N
N
N
N
N
Y
Y
N
N
Y
N
N
N
N
N
N
N
N
N
N
N
N
Y
Y
N
Y
N
N
Y
N
N
N
N
Y
Y
Y
Y
Y
Y
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
Y
N
N
N
Y
N
Y
Y
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
Y
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
Y
N
Y
N
Y
N
N
N
N
N
36
Atributos:
ACTIVADA
DESACTIVADA
Audvel
Silencioso
Fixo
Pulsado
Y
Y
N
N
N
N
Atributos:
ACTIVADA
DESACTIVADA
00 Zona nula (no utilizada)
01 Retardo 1
02 Retardo 2
03 Instantneo
04 Interno
05 Interno, Stay/Away
06 Retardo, Stay/Away
07 Incndio com retardo 24 horas (com fio)
08 Incndio padro 24hrs (com fio)
09 Superviso 24 horas
10 Cigarra de superviso 24hrs.
11 Roubo 24 horas
12 Assalto (hold-up) 24 horas
13 Gs 24 horas
14 Aquecimento 24 horas
15 Auxiliar 24 horas
16 Pnico 24 horas
17 Emergncia 24 horas
18 Extintor de incndio 24horas
19 gua 24 horas
20 Congelamento 24 horas
21 Travamento anti-sabotagem 24hr
22 Arme por chave momentneo
23 Arme por chave para manuteno
25 Retardo interno
26 Sem alarme 24 horas
29 Incndio verificado auto.
30 Superviso de incndio
31 Zona diurna
32 Away/Stay instantneo
35 Sirene/Cigarra 24 horas
36 Zona sem travamento anti-sabotagem 24 horas
37 Zona noturna
41 CO 24 horas (com fio)
81 CO 24 horas (sem fio)
87 Incndio com retardo 24 horas (sem fio/
enderevel)
88 Incndio padro 24 horas (sem fio/enderevel)
Seco
[101]
[102]
[103]
[104]
[105]
[106]
Zona #
01
02
03
04
05
06
Tipo de
zona**
(
(
(
(
(
(
)
)
)
)
)
)
Forado
No
Impulso
No
N
N
N
N
N
N
N
N
Y
Y
10
Zona X
No
11
12
13
14
15
16
N.F.
circ.
SEOL
DEOL
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
Audvel
Silencioso
Fixo
Pulsado
Som da
porta
Excluso
Forado
Impulso
Ret. da
transf.
Zona sem
fio
Cruze
Zona
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
37
PowerSeries - PC1616/PC1832/PC1864
Seco
[107]
[108]
[109]
[110]
[111]
[112]
[113]
[114]
[115]
[116]
[117]
[118]
[119]
[120]
[121]
[122]
[123]
[124]
[125]
[126]
[127]
[128]
[129]
[130]
[131]
[132]
[133]
[134]
[135]
[136]
[137]
[138]
[139]
[140]
[141]
[142]
[143]
[144]
[145]
[146]
[147]
[148]
[149]
[150]
[151]
[152]
[153]
[154]
[155]
[156]
[157]
[158]
[159]
[160]
[161]
[162]
[163]
Zona #
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
Tipo de
zona**
(
(
(
(
(
(
(
(
(
(
(
(
(
(
(
(
(
(
(
(
(
(
(
(
(
(
(
(
(
(
(
(
(
(
(
(
(
(
(
(
(
(
(
(
(
(
(
(
(
(
(
(
(
(
(
(
(
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
Audvel
Silencioso
Fixo
Pulsado
Som da
porta
Excluso
Forado
Impulso
Ret. da
transf.
Zona sem
fio
Cruze
Zona
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
38
Seco
[164]
Seco
[101]
[102]
[103]
[104]
[105]
[106]
[107]
[108]
Zona #
64
01
02
03
04
05
06
07
08
Fixo
Pulsado
Som da
porta
Excluso
Forado
Impulso
Ret. da
transf.
Zona sem
fio
Cruze
Zona
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
Tipo de
zona**
Zona #
Audvel
Silencioso
Para uso
futuro
Para uso
futuro
Para uso
futuro
Config.
NC
Config.
SEOL
Config.
SEOL
10
11
12
13
14
15
16
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
I_______I
Tipo de
zona
(
(
(
(
(
(
(
(
)
)
)
)
)
)
)
)
Temporizadores do sistema
[165] Tentativas mximas de chamada para cada nmero de telefone
Padro 005 I_______I_______I_______I As entradas vlidas so 001-005 tentativas
Ms
Semana
Dia
Hora
Incremento
I_______I_______I_______I
I_______I_______I_______I
I_______I_______I_______I
I_______I_______I_______I
I_______I_______I_______I
Ms
Semana
Dia
Hora
Decremento
I_______I_______I_______I
I_______I_______I_______I
I_______I_______I_______I
I_______I_______I_______I
I_______I_______I_______I
I__0__I__0__I__0__I
39
PowerSeries - PC1616/PC1832/PC1864
[181]
[182]
[183]
[184]
[185]
[186]
[187]
[188]
Quarta
Quinta
I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I I_______I_______I:I_______I_______I
Segunda
Tera
I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I I_______I_______I:I_______I_______I
Sexta
Sbado
I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I I_______I_______I:I_______I_______I
Comunicaes
[190] Pr-alerta do arme de nenhuma atividade
Padro
001
Partio
Todas
I________I________I________I
[191]
[192]
[193]
[194]
[195]
[196]
[197]
[198]
1
2
3
4
5
6
7
8
I_______I_______I_______I
I_______I_______I_______I
I_______I_______I_______I
I_______I_______I_______I
I_______I_______I_______I
I_______I_______I_______I
I_______I_______I_______I
I_______I_______I_______I
NOTA: Para os mdulos PC1864/PC1832, o padro a partio 1, zonas 1-16 activadas. Para o mdulo PC1616, o padro a partio 1, zonas
1-6 activadas.
Atribuio de zona partio 1
[202] 1-8
[210] 1-8
[218] 1-8
[226] 1-8
[203] 9-16
[211] 9-16
[219] 9-16
[227] 9-16
[204] 17-24
[212] 17-24
[220] 17-24
[228] 17-24
[205] 25-32
[213] 25-32
[221] 25-32
[229] 25-32
[206] 33-40
[214] 33-40
[222] 33-40
[230] 33-40
[207] 41-48
[215] 41-48
[223] 41-48
[231] 41-48
[208] 49-56
[216] 49-56
[224] 49-56
[232] 49-56
[209] 57-64
[217] 57-64
[225] 57-64
[233] 57-64
40
[234] 1-8
[242] 1-8
[250] 1-8
[258] 1-8
[235] 9-16
[243] 9-16
[251] 9-16
[259] 9-16
[236] 17-24
[244] 17-24
[252] 17-24
[260] 17-24
[237] 25-32
[245] 25-32
[253] 25-32
[261] 25-32
[238] 33-40
[246] 33-40
[254] 33-40
[262] 33-40
[239] 41-48
[247] 41-48
[255] 41-48
[263] 41-48
[240] 49-56
[248] 49-56
[256] 49-56
[264] 49-56
[241] 57-64
[249] 57-64
[257] 57-64
[265] 57-64
[304] Sequncia de cancelamento de chamada em espera (6 Dgitos) - Este recurso activado na seco 382 opo 4
I_______I_______I_______I_______I_______I_______I Padro
NOTA: Todos os seis dgitos devem ser inseridos para que as alteraes sejam salvas. Preencha os espaos dos dgitos no utilizados
com F.
Cdigos de conta
Digite um nmero de conta de seis dgitos para o cdigo de conta do sistema. O SIA utilizar esse cdigo de conta para todas as seis parties.
Somente o SIA suporta cdigos de conta com seis dgitos. Se os dois ltimos dgitos do cdigo de conta forem FF, a Central utilizar apenas os
primeiros quatro dgitos.
I________I________I________I________I________I________I
I________I________I________I________I
I________I________I________I________I
I________I________I________I________I
I________I________I________I________I
I________I________I________I________I
I________I________I________I________I
I________I________I________I________I
I________I________I________I________I
41
PowerSeries - PC1616/PC1832/PC1864
Cdigos de transmisso
[320]-[323] Cdigos de transmisso de alarme, zonas 01-64
Todos os cdigos de transmisso so padronizados em FF, a menos que indicado ao contrrio.
Seo
[320]
Zona 01
Zona 02
Zona 03
Zona 04
Zona 05
Zona 06
I_______I_______I
[321]
[322]
[323]
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
Zona 07
Zona 08
I_______I_______I
I_______I_______I
Zona 09
Zona 10
Zona 11
Zona 12
Zona 13
Zona 14
Zona 15
Zona 16
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
Zona 17
Zona 18
Zona 19
Zona 20
Zona 21
Zona 22
Zona 23
Zona 24
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
Zona 25
Zona 26
Zona 27
Zona 28
Zona 29
Zona 30
Zona 31
Zona 32
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
Zona 33
Zona 34
Zona 35
Zona 36
Zona 37
Zona 38
Zona 39
Zona 40
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
Zona 41
Zona 42
Zona 43
Zona 44
Zona 45
Zona 46
Zona 47
Zona 48
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
Zona 49
Zona 50
Zona 51
Zona 52
Zona 53
Zona 54
Zona 55
Zona 56
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
Zona 57
Zona 58
Zona 59
Zona 60
Zona 61
Zona 62
Zona 63
Zona 64
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
[325]
[326]
[327]
Zona 01
Zona 02
Zona 03
Zona 04
Zona 05
Zona 06
Zona 07
Zona 08
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
Zona 09
Zona 10
Zona 11
Zona 12
Zona 13
Zona 14
Zona 15
Zona 16
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
Zona 17
Zona 18
Zona 19
Zona 20
Zona 21
Zona 22
Zona 23
Zona 24
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
Zona 25
Zona 26
Zona 27
Zona 28
Zona 29
Zona 30
Zona 31
Zona 32
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
Zona 33
Zona 34
Zona 35
Zona 36
Zona 37
Zona 38
Zona 39
Zona 40
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
Zona 41
Zona 42
Zona 43
Zona 44
Zona 45
Zona 46
Zona 47
Zona 48
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
Zona 49
Zona 50
Zona 51
Zona 52
Zona 53
Zona 54
Zona 55
Zona 56
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
Zona 57
Zona 58
Zona 59
Zona 60
Zona 61
Zona 62
Zona 63
Zona 64
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
Alarme de coao
Abertura aps alarme
Fechamento recente
Alarme de superviso do expansor de zonas
Restaurao da superviso do expansor de zonas
Alarme de cruzamento de zona (cdigo policial)
Roubo no verificado
Alarme cancelado
42
Cdigos de transmisso
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
[331]
[332]
[333]
Zona 01
Zona 02
Zona 03
Zona 04
Zona 05
Zona 06
Zona 07
Zona 08
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
Zona 09
Zona 10
Zona 11
Zona 12
Zona 13
Zona 14
Zona 15
Zona 16
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
Zona 17
Zona 18
Zona 19
Zona 20
Zona 21
Zona 22
Zona 23
Zona 24
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
Zona 25
Zona 26
Zona 27
Zona 28
Zona 29
Zona 30
Zona 31
Zona 32
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
Zona 33
Zona 34
Zona 35
Zona 36
Zona 37
Zona 38
Zona 39
Zona 40
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
Zona 41
Zona 42
Zona 43
Zona 44
Zona 45
Zona 46
Zona 47
Zona 48
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
Zona 49
Zona 50
Zona 51
Zona 52
Zona 53
Zona 54
Zona 55
Zona 56
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
Zona 57
Zona 58
Zona 59
Zona 60
Zona 61
Zona 62
Zona 63
Zona 64
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
[335]
[336]
[337]
Zona 01
Zona 02
Zona 03
Zona 04
Zona 05
Zona 06
Zona 07
Zona 08
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
Zona 09
Zona 10
Zona 11
Zona 12
Zona 13
Zona 14
Zona 15
Zona 16
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
Zona 17
Zona 18
Zona 19
Zona 20
Zona 21
Zona 22
Zona 23
Zona 24
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
Zona 25
Zona 26
Zona 27
Zona 28
Zona 29
Zona 30
Zona 31
Zona 32
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
Zona 33
Zona 34
Zona 35
Zona 36
Zona 37
Zona 38
Zona 39
Zona 40
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
Zona 41
Zona 42
Zona 43
Zona 44
Zona 45
Zona 46
Zona 47
Zona 48
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
Zona 49
Zona 50
Zona 51
Zona 52
Zona 53
Zona 54
Zona 55
Zona 56
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
Zona 57
Zona 58
Zona 59
Zona 60
Zona 61
Zona 62
Zona 63
Zona 64
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_________I__________I
I_________I__________I
Bloqueio do teclado
43
PowerSeries - PC1616/PC1832/PC1864
[340]
Cdigo 1
Cdigo 2
Cdigo 3
Cdigo 4
Cdigo 5
Cdigo 6
Cdigo 7
Cdigo 8
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
Cdigo 9
Cdigo 10
Cdigo 11
Cdigo 12
Cdigo 13
Cdigo 14
Cdigo 15
Cdigo 16
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
Cdigo 17
Cdigo 18
Cdigo 19
Cdigo 20
Cdigo 21
Cdigo 22
Cdigo 23
Cdigo 24
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
Cdigo 25
Cdigo 26
Cdigo 27
Cdigo 28
Cdigo 29
Cdigo 30
Cdigo 31
Cdigo 32
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
[343]
Cdigo 1
Cdigo 2
Cdigo 3
Cdigo 4
Cdigo 5
Cdigo 6
Cdigo 7
Cdigo 8
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
Cdigo 9
Cdigo 10
Cdigo 11
Cdigo 12
Cdigo 13
Cdigo 14
Cdigo 15
Cdigo 16
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
Cdigo 17
Cdigo 18
Cdigo 19
Cdigo 20
Cdigo 21
Cdigo 22
Cdigo 23
Cdigo 24
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
Cdigo 25
Cdigo 26
Cdigo 27
Cdigo 28
Cdigo 29
Cdigo 30
Cdigo 31
Cdigo 32
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
[345] Cdigos de transmisso de alarme de manuteno [346] Cdigos de transmisso de restaurao de manuteno
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
Restaurao de TLM
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
Reinicializao do Sistema
I_______I_______I
44
Cdigos de transmisso
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I__0__I___0__I
I_______I_______I
I__0__I___0__I
I_______I_______I
Teste do sistema
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
Cdigo de delinqncia
I_______I_______I
I_______I_______I
I__0__I___0__I
I__0__I___0__I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
I_______I_______I
1 Nmero de Telefone
04
I_______I_______I
2 Nmero de Telefone
04 SIA FSK
05 Formato Pager
03 ID Contato DTMF
06 Discagem residencial**
**A falha na comunicao utilizando a marcao residencial no ir gerar um problema de falha na comunicao.
Seo
[351]
[352]
[353]
[354]
[355]
[356]
[357]
[358]
Opo 1
Opo 2
1 nmero de
2 nmero de
Partio
de telefone
de telefone (Padro
(Padro ATIVADO)
DESATIVADO)
1
2
3
4
5
6
7
8
Opo 3
No utilizado
(Padro
DESATIVADO)
Opo 4
No utilizado
(Padro
DESATIVADO)
Opo 5
Comunicador
alternativo
(Padro
ATIVADO)
Opes 6,7,8
Uso futuro
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
45
PowerSeries - PC1616/PC1832/PC1864
Seo
[359]
[360]
[361]
[362]
[363]
[364]
[365]
[366]
Opo 1
Opo 2
1 nmero de
2 nmero de
Partio
de telefone
de telefone (Padro
(Padro ATIVADO) DESATIVADO)
1
2
3
4
5
6
7
8
Opo 3
No utilizado
(Padro
DESATIVADO)
Opo 4
No utilizado
(Padro
DESATIVADO)
Opo 5
Comunicador
alternativo
(Padro
ATIVADO)
Opes 6,7,8
Uso futuro
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
Seo
[367]
[368]
[369]
[370]
[371]
[372]
[373]
[374]
Opo 1
Opo 2
1 nmero de
2 nmero de
Partio de telefone (Padro de telefone (Padro
DESATIVADO)
DESATIVADO)
1
2
3
4
5
6
7
8
Opo 3
No utilizado
(Padro
DESATIVADO)
Opo 4
No utilizado
(Padro
DESATIVADO)
Opo 5
Comunicador
alternativo
(Padro
DESATIVADO)
Opes 6,7,8
Uso futuro
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
Seo
[375]
Opo 1
Opo 2
1 nmero de
2 nmero de
de telefone (Padro de telefone (Padro
ATIVADO)
DESATIVADO)
I________I
I________I
Opo 3
No utilizado
(Padro
DESATIVADO)
Opo 4
No utilizado
(Padro
DESATIVADO)
Opo 5
Comunicador
alternativo
(Padro ATIVADO)
Opes 6,7,8
Uso futuro
I________I
I________I
I________I
I________I
Seo
[376]
Opo 1
Opo 2
1 nmero de
2 nmero de
de telefone (Padro de telefone (Padro
ATIVADO)
DESATIVADO)
I________I
I________I
Opo 3
No utilizado
(Padro
DESATIVADO)
Opo 4
No utilizado
(Padro
DESATIVADO)
Opo 5
Comunicador
alternativo
(Padro ATIVADO)
Opes 6,7,8
Uso futuro
I________I
I________I
I________I
I________I
46
Cdigos de transmisso
003
001-014 Transmisses
003
I___0__I__0__I___3__I
Desativao da zona (Sabotagem e Rest.)
003
I___0__I__0__I___3__I
Desativao da zona (Manuteno e Rest.)
000
I___0__I__3__I___0__I
Retardo de comunicao
030
I___0__I__3__I___0__I
Retardo da comunicao de falha de CA
010
I___0__I__1__I___0__I
Retardo do problema de TLM
030
I___0__I__3__I___0__I
Ciclo de transmisso de teste (linha terrestre)
030
I___0__I__3__I___0__I
Para uso futuro
007
I___0__I__0__I___7__I
Retardo da bateria com carga baixa na zona
030
I___0__I__3__I___0__I
Ciclo de transmisso de delinquncia
000
I___0__I__0__I___5__I
Janela de cancelamento de comunicaes
Depende da programao da seo [702], opo [3].
I__________I__________I__________I__________I
I__________I__________I__________I__________I
Pad.
3
4
5
6
7
8
ATIVADA
DESATIVADA
Comunicaes habilitadas
Restaurao com o tempo da campainha esgotado
Discagem por pulso
Comutao para discagem por pulso aps 5 tentativas
3 nmero de telefone habilitado
Discagem alternativa (1 e 3)
Para uso futuro
Delinquncia acompanha a atividade da zona (horas)
Comunicaes desabilitadas
Restauraes acompanham zonas
Discagem DTMF
Discagem DTMF para todas as tentativas
3 nmero de telefone desabilitado
Chamada do 1 nmero, reserva para o 3
Pad.
3
4
5
6
7
8
ATIVADA
DESATIVADA
47
PowerSeries - PC1616/PC1832/PC1864
Pad. ATIVADA
4
5
6
DESATIVADA
* Um cancelamento de chamada em espera em uma linha sem a funo de chamada em espera impedir a Ligao bem sucedida com a Central
Receptora.
Pad.
ATIVADA
1
2-8
DESATIVADA
I_________I_________I_________I
Download do DLS
[401] Cdigos de opo de download
Op.
Pad.
1
2
3
4
5
6
7
8
ATIVADA
DESATIVADA
[403]-[404] Cdigo de acesso de download do DLS/Cdigo de identificao do painel (insira 6 digitos hexadecimais)
Painel
Padro
PC1616
161600
|_______|_______|_______|_______|_______|_______|
|_______|_______|_______|_______|_______|_______|
PC1832
183200
|_______|_______|_______|_______|_______|_______|
|_______|_______|_______|_______|_______|_______|
PC1864
186400
|_______|_______|_______|_______|_______|_______|
|_______|_______|_______|_______|_______|_______|
[405] Temporizador de chamada dupia da secretaria [406] Nmero de toques para atender
Padro 060 I_______I_______I_______I
(001-255 segundos)
48
Cdigos de transmisso
Atributo
ACTIVADO
DESACTIVADO
No
utilizado
No
utilizado
Sada
verdadeira
Invertida
Acompanhao
temporizador
Activados/
Desactivados
Cdigo nec.
No
utilizado
No
utilizado
No
utilizado
Opo de PGM
[01] Sada de incndio/roubo residencial
Nenhum cdigo
nec.
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Atributo
Opo de PGM
Y
Y
Y
Y
Y
Y
Y
N
N
N
Serv. nec.
Falha de
CA
Falha de
TLM
FTC
Falha de
Zona
Sabotagem
de zona
Bateria
fraca na
zona
Perda de
relgio
Desabilitado
Desabilitado
Desabilitado
Desabilitado
Desabilitado
Desabilitado
Evento de
incndio
Evento de
pnico
Evento
mdico
Evento de
superv.
Evento de
prioridade
Evento de
assalto
Acompanha o
temporizador*
Desabilitado
Desabilitado
Desabilitado
Desabilitado
Desabilitado
Travado
Alarme
mdico
Cdigo
Policial
Ativo quando
verdadeiro
Activada
Activada Evento de
roubo
[10] Evento do sistema
Activada
Alarme de Alarme de
incndio
pnico
Alarme de
roubo
Abertura/
Inhibio
fechament automatica
o
da zona
Desabilitado
Desabilitado
Desabilitado
Desabilitado
Desabilitado
Travado
Uso futuro
Uso
futuro
Uso futuro
Uso
futuro
Uso futuro
Uso futuro
Uso futuro
Uso futuro
Uso futuro
E Lgico
Desactivada
Acompanha o
temporizador
Uso futuro
Travado
Sada
Uso futuro
verdadeira
49
PowerSeries - PC1616/PC1832/PC1864
Atributo
Opo de PGM
Desactivada
Seco
PGM
#
Invertida
Tipo de
Saida*
OU Lgico
Placa principal
[501]
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
[502]
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
[503] **
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
[504] **
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
Placa principal/PC5208
Seco
PGM
#
Tipo de
Saida*
PC5208
[505]
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
[506]
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
[507]
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
[508]
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
[509]
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
[510]
10
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
[511]
11
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
[512]
12
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
[513]
13
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
[514]
14
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
PC5204
PGM
Partio:
#
Placa principal
[551]
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
[552]
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
[553]
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
[554]
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
[555]
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
[556]
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
[557]
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
Placa principal/PC5208
PC5208
50
Cdigos de transmisso
[558]
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
[559]
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
[560]
10
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
[561]
11
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
[562]
12
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
[563]
13
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
[564]
14
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
I____________I
PC5204
Zona 1
Zona 2
Zona 3
Zona 4
Zona 5
Zona 6
Zona 7
Zona 8
Zona 9
Zona 10
Zona 11
Zona 12
Zona 13
Zona 14
Zona 15
Zona 16
Zona 17
Zona 18
Zona 19
Zona 20
Zona 21
Zona 22
Zona 23
Zona 24
Zona 25
Zona 26
Zona 27
Zona 28
Zona 29
Zona 30
Zona 31
Zona 32
Zona 33
Zona 34
Zona 35
Zona 36
Zona 37
Zona 38
Zona 39
Zona 40
Zona 41
Zona 42
Zona 43
Zona 44
Zona 45
Zona 46
Zona 47
Zona 48
Zona 49
Zona 50
Zona 51
Zona 52
Zona 53
Zona 54
Zona 55
Zona 56
Zona 57
Zona 58
Zona 59
Zona 60
Zona 61
Zona 62
Zona 63
Zona 64
[602]
[603]
[604]
Cdigo 33
Cdigo 34
Cdigo 35
Cdigo 36
Cdigo 37
Cdigo 38
Cdigo 39
Cdigo 40
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
Cdigo 41
Cdigo 42
Cdigo 43
Cdigo 44
Cdigo 45
Cdigo 46
Cdigo 47
Cdigo 48
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
Cdigo 49
Cdigo 50
Cdigo 51
Cdigo 52
Cdigo 53
Cdigo 54
Cdigo 55
Cdigo 56
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
Cdigo 57
Cdigo 58
Cdigo 59
Cdigo 60
Cdigo 61
Cdigo 62
Cdigo 63
Cdigo 64
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
Cdigo 65
Cdigo 66
Cdigo 67
Cdigo 68
Cdigo 69
Cdigo 70
Cdigo 71
Cdigo 72
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
Cdigo 73
Cdigo 74
Cdigo 75
Cdigo 76
Cdigo 77
Cdigo 78
Cdigo 79
Cdigo 80
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
Cdigo 81
Cdigo 82
Cdigo 83
Cdigo 84
Cdigo 85
Cdigo 86
Cdigo 87
Cdigo 88
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
Cdigo 89
Cdigo 90
Cdigo 91
Cdigo 92
Cdigo 93
Cdigo 94
Cdigo 95
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
51
PowerSeries - PC1616/PC1832/PC1864
[606]
[607]
[608]
Cdigo 33
Cdigo 34
Cdigo 35
Cdigo 36
Cdigo 37
Cdigo 38
Cdigo 39
Cdigo 40
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
Cdigo 41
Cdigo 42
Cdigo 43
Cdigo 44
Cdigo 45
Cdigo 46
Cdigo 47
Cdigo 48
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
Cdigo 49
Cdigo 50
Cdigo 51
Cdigo 52
Cdigo 53
Cdigo 54
Cdigo 55
Cdigo 56
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
Cdigo 57
Cdigo 58
Cdigo 59
Cdigo 60
Cdigo 61
Cdigo 62
Cdigo 63
Cdigo 64
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
Cdigo 65
Cdigo 66
Cdigo 67
Cdigo 68
Cdigo 69
Cdigo 70
Cdigo 71
Cdigo 72
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
Cdigo 73
Cdigo 74
Cdigo 75
Cdigo 76
Cdigo 77
Cdigo 78
Cdigo 79
Cdigo 80
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
Cdigo 81
Cdigo 82
Cdigo 83
Cdigo 84
Cdigo 85
Cdigo 86
Cdigo 87
Cdigo 88
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
Cdigo 89
Cdigo 90
Cdigo 91
Cdigo 92
Cdigo 93
Cdigo 94
Cdigo 95
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
I_________I_________I
[681]
[682]
[683]
[684]
[685]
[686]
[687]
[688]
Segunda
Tera
Quarta
Quinta
Sexta
Sbado
I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I
I_______I_______I:I_______I_______I I_______I_______I:I_______I_______I
[691]
Feriado 1
Feriado 2
Feriado 3
Feriado 4
Feriado 5
Feriado 6
Feriado 7
Feriado 8
Feriado 9
Feriado 10
Feriado 11
Feriado 12
Feriado 13
Feriado 14
[692]
Feriado 1
Feriado 2
Feriado 3
Feriado 4
Feriado 5
Feriado 6
Feriado 7
Feriado 8
Feriado 9
Feriado 10
Feriado 11
Feriado 12
Feriado 13
Feriado 14
[693]
Feriado 1
Feriado 2
Feriado 3
Feriado 4
Feriado 5
Feriado 6
Feriado 7
Feriado 8
Feriado 9
Feriado 10
Feriado 11
Feriado 12
Feriado 13
Feriado 14
[694]
Feriado 1
Feriado 2
Feriado 3
Feriado 4
Feriado 5
Feriado 6
Feriado 7
52
Cdigos de transmisso
Feriado 8
Feriado 9
Feriado 10
Feriado 11
Feriado 12
Feriado 13
Feriado 14
[695]
Feriado 1
Feriado 2
Feriado 3
Feriado 4
Feriado 5
Feriado 6
Feriado 7
Feriado 8
Feriado 9
Feriado 10
Feriado 11
Feriado 12
Feriado 13
Feriado 14
[696]
Feriado 1
Feriado 2
Feriado 3
Feriado 4
Feriado 5
Feriado 6
Feriado 7
Feriado 8
Feriado 9
Feriado 10
Feriado 11
Feriado 12
Feriado 13
Feriado 14
[697]
Feriado 1
Feriado 2
Feriado 3
Feriado 4
Feriado 5
Feriado 6
Feriado 7
Feriado 8
Feriado 9
Feriado 10
Feriado 11
Feriado 12
Feriado 13
Feriado 14
[698]
Feriado 1
Feriado 2
Feriado 3
Feriado 4
Feriado 5
Feriado 6
Feriado 7
Feriado 8
Feriado 9
Feriado 10
Feriado 11
Feriado 12
Feriado 13
Feriado 14
PROGRAMAO INTERNACIONAL
[700] Ajuste automtico do relgio
Padro = 60
|__________|__________|
Pad.
ATIVADA
DESATIVADA
CA 50 Hz
Base de tempo Cristal interno
Excluso do arme CA/CC com habilitada
Todas as sabotagens do sistema requerem a reinicializao do instalador
Cdigos de acesso do usurio com 6 dgitos
Deteco de tom de linha ocupada habilitada
Carga da bateria de alta corrente
DLS/udio sem prioridade
CA 60 Hz
Base de tempo Linha CA
Excluso do arme CA/CC com desabilitada
Todas as sabotagens do sistema acompanham a restaurao
Cdigos de acesso do usurio com 4 dgitos
Deteco de tom de linha ocupada desabilitada
Descarga da bateria de corrente padro
DLS/udio com prioridade
Pad. ATIVADA
4
5
6
DESATIVADA
|__________|__________|__________|
Programao do mdulo
[801] Programao do mdulo de impresso PC5400
Consulte o manual de instalao do PC5400 para obter instrues sobre a instalao e a programao.
54
Para registrar
Para registrar
Cliente: _________________________________________________________________________________________________________
Endereo:__________________________________________________________________________________________
Telefone: ______________________________________________ Data de instalao: _____________________________________
Cdigo do instalador: _________________________________________________________________________________
55
Nome da Zona
Tipo de
Zona
Sistema
Zona
Nome da Zona
Tipo de
Zona
Zona 1
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 33
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 2
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 34
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 3
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 35
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 4
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 36
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 5
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 37
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 6
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 38
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 7
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 39
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 8
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 40
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 9
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 41
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 10
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 42
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 11
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 43
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 12
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 44
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 13
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 45
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 14
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 46
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 15
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 47
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 16
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 48
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 17
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 49
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 18
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 50
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 19
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 51
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 20
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 52
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 21
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 53
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 22
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 54
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 23
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 55
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 24
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 56
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 25
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 57
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 26
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 58
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 27
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 59
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 28
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 60
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 29
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 61
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 30
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 62
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 31
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 63
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 32
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
Zona 64
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I
56
O primeiro dgito (entre parnteses) ser automaticamente transmitido pelo controlo. Os dois dgitos seguintes so programados para indicar informaes especficas sobre o sinal. Por exemplo, se a zona 1 for um ponto de entrada/sada, voc pode programar o cdigo do evento como [34]. A
Central Receptora receberia o seguinte:
*BURG - ENTRY/EXIT 1 onde "1" indica que zona est sob alarme.
Formato SIA Nvel 2 (Codificado)
O formato de comunicao SIA utilizado neste sistema obedece s especificaes do nvel 2 da norma de comunicao digital SIA outubro de
1997. Este formato transmite o cdigo de conta juntamente com a data de transmisso. NOTA: Um evento de sistema ir utilizar o identificador de rea Ri00. A transmisso ser similar ao que segue no receptor:
N Ri01
N
Ri01
Seo n.
[320]-[323]
[324]-[327]
[328]
[328]
[328]
[328]
BA 01
= Novo evento
= Identificador da partio/rea
Cdigo de transmisso
[328]
Alarmes de zona
Restauraes de zonas
Alarme de coao
Abertura aps alarme
Fechamento recente
Alarme/Rest. da superviso do
expansor de zonas
Alarme de cruzamento de zona
(cdigo policial)
Roubo no verificado
[328]
[329]
Alarme cancelado
Alarme/Restaurao da tecla [F]
[329]
[329]
[329]
Alarme/Restaurao da entrada
auxiliar
[328]
[330]-[337]
Sabotagem/Restaurao de zona
[338]
Sabotagem/Restaurao geral do
sistema
Bloqueio do teclado
Fechamentos
Fechamento parcial
Fechamento especial
[338]
[339-341]
[341]
[341]
[341]
[341]
Falha de sada
[341]
[341]
[342-344]
[344]
[344]
Zona inibida
Aberturas
Cancel. do arme automtico
Abertura especial
[345]-[346]
Problema/Rest. da bateria
[345]-[346]
Problema/Restaurao da linha
CA
[345]-[346]
Problema/Restaurao do
circuito da campainha
Problema/Rest. de incndio
[345]-[346]
[345]-[346]
[345]-[346]
Problema/Rest. de alimentao
auxiliar
Falha/Restaurao no TLM
BA
01
= Alarme de roubo
= Zona 1
Cdigos de
identificao
automtica do
contato
Cdigos de
transmisso
automtica SIA**
Veja a tabela 3
Veja a tabela 3
HA-00
OR-UU
CR-00
UA-00/UH-00
A/R
E(1)21-000
E(4)58-000
E(4)59-UUU
E(1)43-000/
R(1)43-000
E(1)39-000
A/R
E(3)78-000
BG-00
A/R
A/R
BC-00
FA-00/FH-00
T/R
O/C
O/C
O/C
E(4)A6-UUU
E(1)1A-000/
R(1)1A-000
E(1)AA-000/
R(1)AA-000
E(1)2A-000/
R(1)2A-000
E(1)4A-000/
R(1)4A-000
E(1)11-000/
R(1)11-000
E(3)83-ZZZ/
R(3)83-ZZZ
E(1)45-000/
R(1)45-000
E(4)61-000
R(4)A1-UUU
E(4)56-000
R(4)AA-000
O/C
R(4)54-000
CI-00
O/C
E(3)74-ZZZ
EE-00
O/C
R(5)7A-ZZZ
UU-ZZ
O/C
O/C
O/C
O/C
E(5)7A-ZZZ
E(4)A1-UUU
E(4)55-000
E(4)AA-000
UB-ZZ
OP-UU
CI-00
OP-00
MA/R
E(3)A2-000/
R(3)A2-000
E(3)A1-000/
R(3)A1-000
YT-00/YR-00
E(3)21-000/
R(3)21-000
E(3)73-000/
R(3)73-000
E(3)12-000/
R(3)12-000
E(3)51-000/
R(3)51-000
YA-99/YH-99
Direcionamento do
discador*
A/R
A/R
A/R
A/R
A/R
A/R
A/R
A/R
A/R
A/R
T/R
T/R
MA/R
MA/R
MA/R
57
MA/R
MA/R
BM-00/BV-00
MA-00/MH-00
PA-00/PH-00
UA-99/UH-99
FA-99/FH-99
TA-ZZ/TR-ZZ
ES-00/EJ-00
JA-00
CL-UU
CG-00
CL-00
AT-00/AR-00
FT-99/FJ-99
YP-00/YQ-00
LT-01/LR-01
Cdigo de transmisso
[345]-[346]
Problema/Restaurao geral do
sistema
Problema/Restaurao da
superviso geral do sistema
Reinicializao do Sistema
MA/R
MA/R
[345]-[346]
[346]
[347]
[347]
[347]
[347]
[347]
[347]
Delinquncia
[347]
Cdigos de
identificao
automtica do
contato
Direcionamento do
discador*
Seo n.
Cdigos de
transmisso
automtica SIA**
YX-00/YZ-00
MA/R
E(3)AA-000/
R(3)AA-000
E(3)3A-000/
R(3)3A-000
R(3)A5-000
MA/R
R(3)54-000
YK-00
MA/R
MA/R
MA/R
MA/R
E(6)22-000
E(4)11-000
E(4)12-000
E(3)8A-ZZZ/
R(3)8A-ZZZ
E(6)54-000***
JL-00
RB-00
RS-00
UT-ZZ/UJ-ZZ
E(3)84-000/
R(3)84-000
XT-00/XR-00
XT-ZZ/XRZZ****
LB-00/LS-00
MA/R
MA/R
[347]
ET-00/ER-00
RR-00
CD-00
Entrada/Sada do com. do
O modo do instalador precisa ser ativado/desativado
MA/R
E(6)27-000/
instalador
E(6)28-000
[348]
Fim/Incio do teste de
Fim do teste/Incio do teste
T
R(6)A7-UUU/
TE-00/TS-00
caminhada
E(6)A7-UUU
[348]
Teste peridico com problema
Transmisso do teste peridico do sistema com problema
T
E(6)A8-000
RY-00
[348]
Teste peridico
Transmisso do teste peridico do sistema
T
E(6)A2-000
RP-00
[348]
Teste do sistema
[*][6] teste da campainha/comunicaes
T
E(6)A1-000
RX-00
[349]
Problema/Restaurao da falha Aterramento/Falha/Problema ocorre no mdulo PC5700
MA/R
E(3)1A-000
US-00/UR-00
do terra do PC5700
[349]
Problema/Restaurao da linha Problema/Restaurao de TLM ocorre no mdulo PC5700
MA/R
E(3)51-000/
LT-01/LR-01
1 de TLM do PC5700
R(3)51-000
[349]
Problema/Restaurao da linha Problema/Restaurao de TLM ocorre no mdulo PC5700
MA/R
E(3)52-000/
LT-02/LR-02
2 de TLM do PC5700
R(3)52-000
[601]-[604] Fechamentos
Sistema armado (usurio 33-95 indicado)
O/C
R(4)A1-UUU
CL-UU
[605]-[608] Aberturas
Sistema desarmado (usurio 33-95 indicado)
O/C
E(4)A1-UUU
OP-UU
*A/R = alarmes/restauraes; T/R = violaes/restauraes; O/C = aberturas/fechamentos; MA/R = alarmes/restauraes diversos; T = transmisses de teste
** UU = nmero do usurio (user01-42); ZZ = nmero da zona (01-64)
***Utilize o cdigo de evento "Fail to close" (Falha ao fechar) [(4)54] para relatar uma atividade de fechamento ou delinqncia. Assegure-se de que a estao central seja informada
de que este cdigo est sendo utilizado.
****As zonas so identificadas, porm pnico pendente, teclados sem fio e teclados portteis no so.
(1)34 Entrada/Sada
(1)35 Dia/Noite
(1)36 Externo
(1)37 Sabotagem
(1)38 Alarme de aproximao
Alarmes gerais
(1)4A Alarme geral
(1)43 Falha do mdulo exp.
(1)44 Sabotagem do sensor
(1)45 Sabotagem do mdulo
(1)4A Cdigo policial de cruzamento
de zona
No roubo 24 horas
(1)5A No roubo 24 Horas
(1)51 Gs detectado
(1)52 Refrigerao
(1)53 Perda de calor
(1)54 Vazamento de gua
(1)55 Invaso frustrada
(1)56 Problema no dia
(1)57 Nvel baixo de gs engarrafado
(1)58 Alta temperatura
(1)59 Baixa temperatura
(1)61 Perda do fluxo de ar
Cdigos de
transmisso
automtica SIA*
Cd. de trans.
auto. de ID de
contato*
Cd. de trans.
auto. rest. de ID
de contato*
Retardo 1
Retardo 2
Instantneo
Interno
Presente/Ausente interno
Presente/Ausente com retardo
Incndio 24 horas com retardo
Incndio 24 horas padro
Superviso 24 horas
Cigarra de superviso 24 horas
Roubo 24 horas
Assalto 24 horas
Gs 24 horas
Calor 24 horas
Mdico 24 horas
Pnico 24 horas
Emergncia 24 horas (no mdica)
Extintor de incndio 24 horas
gua 24 horas
Congelamento 24 horas
Fechamento 24 horas
Retardo interno
Incndio verificado auto.
Superviso de incndio 24 horas
Zona diurna
Presente/Ausente instantneo
Campainha/Cigarra 24 horas
Travamento anti-sabotagem 24hr
Zona noturna
Incndio 24 hr com retardo (sem fio)
Incndio 24 horas padro (sem fio)
Alarme de CO 24 horas
BA-ZZ/BH-ZZ
BA-ZZ/BH-ZZ
BA-ZZ/BH-ZZ
BA-ZZ/BH-ZZ
BA-ZZ/BH-ZZ
BA-ZZ/BH-ZZ
FA-ZZ/FH-ZZ
FA-ZZ/FH-ZZ
US-ZZ/UR-ZZ
UA-ZZ/UH-ZZ
BA-ZZ/BH-ZZ
HA-ZZ/HH-ZZ
GA-ZZ/GH-ZZ
KA-ZZ/KH-ZZ
MA-ZZ/MH-ZZ
PA-ZZ/PH-ZZ
QA-ZZ/QH-ZZ
SA-ZZ/SH-ZZ
WA-ZZ/WH-ZZ
ZA-ZZ/ZH-ZZ
UA-ZZ/UH-ZZ
BA-ZZ/BH-ZZ
FA-ZZ/FH-ZZ
FS-ZZ/FV-ZZ
BA-ZZ/BH-ZZ
BA-ZZ/BH-ZZ
UA-ZZ/UH-ZZ
UA-ZZ/UH-ZZ
BA-ZZ/BH-ZZ
FA-ZZ/FH-ZZ
FA-ZZ/FH-ZZ
GA-ZZ/GH-ZZ
E(1)3A-ZZZ
E(1)3A-ZZZ
E(1)3A-ZZZ
E(1)3A-ZZZ
E(1)3A-ZZZ
E(1)3A-ZZZ
E(1)1A-ZZZ
E(1)1A-ZZZ
E(1)5A-ZZZ
E(1)5A-ZZZ
E(1)3A-ZZZ
E(1)22-ZZZ
E(1)51-ZZZ
E(1)58-ZZZ
E(1)AA-ZZZ
E(1)2A-ZZZ
E(1)A1-ZZZ
E(1)13-ZZZ
E(1)54-ZZZ
E(1)59-ZZZ
E(1)4A-ZZZ
E(1)3A-ZZZ
E(1)1A-ZZZ
E(2)AA-ZZZ
E(1)3A-ZZZ
E(1)3A-ZZZ
E(1)5A-ZZZ
E(1)4A-ZZZ
E(1)3A-ZZZ
E(1)1A-ZZZ
E(1)1A-ZZZ
E(1)62-ZZZ
R(1)3A-ZZZ
R(1)3A-ZZZ
R(1)3A-ZZZ
R(1)3A-ZZZ
R(1)3A-ZZZ
R(1)3A-ZZZ
R(1)1A-ZZZ
R(1)1A-ZZZ
R(1)5A-ZZZ
R(1)5A-ZZZ
R(1)3A-ZZZ
R(1)22-ZZZ
R(1)51-ZZZ
R(1)58-ZZZ
R(1)AA-ZZZ
R(1)2A-ZZZ
R(1)A1-ZZZ
R(1)13-ZZZ
R(1)54-ZZZ
R(1)59-ZZZ
R(1)4A-ZZZ
R(1)3A-ZZZ
R(1)1A-ZZZ
R(2)AA-ZZZ
R(1)3A-ZZZ
R(1)3A-ZZZ
R(1)5A-ZZZ
R(1)4A-ZZZ
R(1)3A-ZZZ
R(1)1A-ZZZ
R(1)1A-ZZZ
R(1)62-ZZZ
* ZZ = zonas 01-64
58
Alimente o sistema.
Programe as opes conforme necessrio (Consulte a seco de programao)
Soluo de problemas:
Teclado com LCD de mensagens programveis
Pressione [,][2] para visualizar uma condio de problema.
A luz de problema ir piscar e o LCD exibir a primeira condio de problema presente.
Utilize as teclas de seta para navegar por todas as condies de problema presentes.
NOTA: Quando estiverem disponveis informaes adicionais para uma condio de problema especfica, um [ ]
ir aparecer no visor.
Pressione a tecla [,] para visualizar as informaes adiccionais.
Teclados com LED, teclados com LCD de mensagens fixas
Pressione [ ,][2] para visualizar uma condio de problema.
A luz de problema ir piscar.
Consulte a tabela de resumo de problemas para determinar a(s) condio(es) de problema presente(s).
Resumo de problemas:
Luz [1]
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
Bateria fraca
Circuito da campainha
Problema geral no sistema
Violao geral do sistema
Superviso do mdulo
Bloqueio de RF detectado
Bateria fraca no PC5204
Falha de CA no PC5204
Luz [6]
Luz [7]
, Bateria fraca no dispositivo sem fio Pressione [7] para obter mais informaes.
59
60
61
IMPORTANTE!
Certifique-se de que possui a documentao a seguir antes de contatar o suporte ao cliente.
- Tipo e verso da Central de controlo (exemplo: PC1864 v4.7).
NOTA: O nmero da verso pode ser visualizado digitando [][Cdigo do instalador][900] em qualquer teclado com LCD. Esta informao o tambm est localizada numa etiqueta na placa de circuito.
- Lista dos mdulos ligados Central de controlo (exemplo: PC5400, PC5204 etc.)
62
Opo
Zn1
Zn2
Zn3
Zn4
Zn5
Zn6
Zn7
Zn8
1 Retardo 1
2 Retardo 2
3 Instantneo
4 Interno
5 Presente/Ausente Interno
Opo
[013] Opo 1
[013] Opo 2
Circuitos normalmente
fechado
ON
OFF
SEOL (5,6
OFF
OFF
DEOL
OFF
ON
No da
Opo
Linha telefnica 1
Desabilitada
Cdigos de transmisso
automtica SIA habilitados
Seco de Programao
[380] Opo 1 DES.
Linha telefnica 2
Seco de Programao
Desabilitada
[350]
n . de telefone
[04]
[380] Opo 1 Act. (ON)
[381] Opo 3 Des. (OFF)
Cdigos de transmisso
automtica SIA habilitados
Cdigos de transmisso de
contacto ID habilitados
Cdigos de transmisso
automtica SIA habilitados
Cdigos de transmisso
automtica SIA habilitados
Marao residencial
habilitados
Cdigos de transmisso de
contacto ID habilitados
Marao residencial
habilitados
Cdigos de transmisso de
contacto ID habilitados
Contact ID Reporting
Codes Enabled
1o
63
PowerSeries - PC1616/PC1832/PC1864
Grupo
Comum
Problemas
seleccionados
Aberturas /
fechamentos
Restauraes
de zona
DLS/Instalador
Entrada/Saida do comando
1
2
3
4
5
6
7
8
indica incluse, campo em branco indica configurao padro, indica desabilitado
Grupo comum
Descrio
Tel. 1
Tel. 2
Sees
Problemas Seleccionados
Problemas
[345] Alarmes
[346] Restaurao
Bateria
FF
Falha de CA
00
Circuito de Sirene
FF
Incndio, alarme
FF
PS auxiliar
FF
TLM
00
Sistema geral
00
Superviso do sistema geral
FF
FF = Communicao em formato automtico, 00 = Desabilitado
FF
00
FF
FF
FF
FF
00
FF
Aberturas e Fechamentos
Utilizadores
Seco
1-8
51
52
53
54
55
56
57
58
[339]
9-16
61
62
63
64
65
66
67
68
[339]
17-24
71
72
73
74
75
76
77
78
[340]
25-32
81
82
83
84
85
86
87
88
[340]
33-40
FF
FF
FF
FF
FF
FF
FF
98
[601]
Utilizadores
Seco
1-8
11
12
13
14
15
16
17
18
[342]
9-16
21
22
23
24
25
26
27
28
[342]
17-24
31
32
33
34
35
36
37
38
[343]
25-32
41
42
43
44
45
46
47
48
[343]
33-40
FF
FF
FF
FF
FF
FF
FF
98
[605]
64
[367]
Restauraes de zona
Zonas
1-64
00
00
00
00
00
00
00
Seco
00
[324]-[327]
00 = Desabilitado
DEF
DEF
DEF
00
00
DEF
DEF
DEF
DEF
Seco
DEF
00
00
[347]
Seco de Programao
65
PowerSeries - PC1616/PC1832/PC1864
01
02
03
04
05
06
07
08
09
10
11
12
13
Formato da Comunicao
SIA (Nvel 2)
SIA um formato especializado que comunicar informao
rapidamente usando a modulao em frequncia por chaveamento (FSK) em vez de pulsos. O formato SIA gera automaticamente o tipo de sinal que est a ser transmitido, tal como
Assalto, Incndio, Pnico, etc. O Cdigo de reporte de dois dgitos usado para identificar o nmero de cdigo de zona ou de
acesso.
Se a opo Enviar Cdigos de Reporte Automticos SIA for activada, o painel funcionar da seguinte forma:
1. Se o cdigo de reporte de um evento for programado como
[00], o painel no tentar ligar para a estao central.
2. Se o cdigo de reporte de um evento for programado como
qualquer valor entre [01] e [FF], o painel gerar AUTOMATICAMENTE o nmero de cdigo de zona ou de acesso.
3. As zonas omitidas sero sempre identificadas quando o sistema parcialmente fechado.
As Opes Instruo de Chamada do Comunicador podem ser
usadas para desactivar o reporte de eventos tais como Aberturas/
Fechos. Da mesma forma, se todos os cdigos de reporte de Abertura/Fecho foram programados como [00], o painel no proceder
ao reporte. Se a opo Enviar Cdigos de Reporte Automticos SIA
for desactivada, o painel funcionar da seguinte forma: Se o cdigo
de reporte de um evento for programado como [00] ou [FF], o painel
no tentar chamar a estao central.
Se o cdigo de reporte de um evento for programado como qualquer valor entre [01] e [FF], o painel enviar o cdigo de reporte
programado.
As zonas omitidas no sero identificadas quando o sistema
parcialmente fechado..
NOTA: O nmero de zona para eventos Bateria Fraca de Zona e
Falha de Zona no ser identificado quando usado o formato SIA
Programado.
Cdigos de Reporte
SIA - 0 valido no Cdigo de Conta ou de Rep (contudo, 00
no o so num Cdigo de Reporte)
ADEMCO Contacto ID O 0 no vlido no Cdigo de Conta
ou de Rep (deve ser usado o A, o 10 no teste por soma)
Formatos BPS - O 0 no vlido num Cdigo de Conta ou de
Rep (tem que ser usado o A)
SIA Este formato usa uma FSK de 300 Baud como o meio
de comunicao. O Cdigo de Conta pode ter 4 ou 6 dgitos
hexadecimais de comprimento. Todos os cdigos de reporte
tm que ter 2 dgitos de comprimento. O formato SIA transmite um cdigo de conta com 4 (ou 6) dgitos, um cdigo de
identificao de 2 dgitos e um cdigo de reporte de 2 dgitos.
O identificador de 2 dgitos pr-programado pelo painel.
Contacto ID
O Contacto ID um formato especializado que comunicar informaes rapidamente usando tons em vez de pulsos. Para alm
de enviar informaes mais rapidamente, o formato permite
igualmente que sejam enviadas mais informaes. Por exemplo,
em vez de reportar uma zona de alarme 1, o formato do Contacto ID pode igualmente reportar o tipo de alarme, tal como
zona 1 de alarme de Entrada/Sada.
Se estiver seleccionada a opo Contacto ID Envia Cdigos de
Reporte Automticos, o painel gerar automaticamente um
cdigo de reporte para cada evento. Estes identificadores esto
listados no Apndice A. Se a opo Contacto ID Automtico no
estiver seleccionada, os cdigos de reporte tm que ser programados. A entrada de 2 dgitos determina o tipo de alarme. O painel gerar automaticamente todas as outras informaes,
incluindo o nmero de zona.
NOTA: Se a opo Contacto ID Automtico for seleccionada, o painel gerar automaticamente os nmeros da zona e do cdigo de
acesso eliminando a necessidade de programar estes itens.
NOTA: O nmero de zona para eventos de Bateria Fraca de Zona e
de Falha de Zona no ser identificado quando o Contacto ID Programado usado.
Se a opo Contacto ID usa Cdigos de Reporte Automticos
estiver activada, o painel funcionar da seguinte forma:
Se o cdigo de reporte de um evento for programado como
[00], o painel no tentar chamar a estao central.
Se o cdigo de reporte de um evento for programado como
qualquer valor entre [01] e [FF], o painel gerar automaticamente o nmero de zona ou do cdigo de acesso. Consulte o
Apndice A para obter a lista de cdigos que sero transmitidos.
66
Discagem Residencial
Formatos de Pulso
Consoante o formato de pulso seleccionado, o painel comunicar usando o seguinte:
3/1, 3/2, 4/1 ou 4/2
handshake de 1400 ou 2300 Hz
10 ou 20 bits por segundo
no estendido
O dgito 0 no enviar quaisquer pulsos e usado como um
dgito de preenchimento. Ao programar nmeros de conta introduza quarto dgitos. Ao programar um nmero de conta de trs
dgitos, o quarto dgito tem que ser programado como um 0
simples que actuar como um dgito de preenchimento.
Se um nmero de conta tiver um 0, substitua um dgito HEXADECIMAL A pelo 0. Exemplos:
nmero de conta com 3 dgitos [123] - programe [1230]
nmero de conta com 3 dgitos [502] - programe [5A20]
nmero de conta com 4 dgitos [4079] - programe [4A79]
Ao programar cdigos de reporte tm que ser introduzidos dois
dgitos. Se for utilizar cdigos de reporte de um dgito, o segundo
dgito tem que ser programado como um 0. Se precisar de
transmitir um 0, substitua o 0 por um dgito HEXADCIMAL
A.
Exemplos:
cdigo de reporte de 1 dgito [3] - programe [30]
cdigo de reporte de 2 dgitos [30] - programe [3A]
Para impedir que o painel reporte um evento, programe o cdigo
de reporte para o evento como [00] ou [FF].
Formato Pager
A opo Formato de Comunicador para qualquer dos nmeros
de telefone pode ser programada para o Formato Pager. Se
ocorrer um evento e as opes de Instruo de Chamada do
Comunicador encaminharem a chamada para um nmero de
telefone que tenha o Formato Pager seleccionado, o painel tentar efectuar a radiochamada.
Quando se liga para um pager sero necessrios dgitos extra
para que este funcione correctamente. Segue-se uma lista dos
dgitos Hexadecimais e qual a funo que desempenham:
Hex [A] - no usado
Hex [B] - simula a tecla [] num telefone de teclado digital (touch
tone),
Hex [E] - pausa de dois segundos
Hex [C] - simula a tecla [#] num telefone de teclado digital (touch
tone)
Hex [F] - fim do marcador do nmero de telefone
Hex [D] - fora o painel a procurar o tom de discagem
O painel tentar ligar para o pager uma vez. Depois de discar os
dgitos do nmero de telefone, o painel enviar o nmero de
conta e o cdigo de reporte seguidos da tecla [#] (Hex [C]).
No h retorno da chamada quando utilizado o Formato Pager.
O painel no tem forma de confirmar se o pager foi chamado
com sucesso; s ser gerada uma falha na comunicao do problema assim que for atingido o nmero mximo de tentativas.
67
PowerSeries - PC1616/PC1832/PC1864
68
Falhas do Sistema
Este sistema foi cuidadosamente projetado para ser to eficaz quanto possvel. Entretanto, h
circunstncias que envolvem incndio, roubo ou outros tipos de emergncia, onde este poderia no
oferecer proteo. Qualquer sistema de alarme de qualquer tipo pode estar comprometido
deliberadamente ou pode falhar ao operar como esperado por uma variedade de razes. Algumas, mas
no todas destas razes podem ser:
Instalao Inadequada
Um sistema de segurana deve ser instalado adequadamente a fim de fornecer uma proteo adequada.
Cada instalao dever ser avaliada por um profissional de segurana para garantir que todos os pontos
e reas de acesso sejam cobertos. Fechaduras e trancas em janelas e portas devem ser fixadas e operar
como previsto. Janelas , portas, paredes, tetos e outros materiais de construo devem ser de suficiente
resistncia e construo para oferecer o nvel de proteo esperado. Uma reavaliao deve ser feita
durante e aps qualquer atividade de construo. Uma avaliao pelo departamento de incndio e/ou de
polcia extremamente recomendada se este servio estiver disponvel.
Conhecimento criminal
Este sistema contm recursos de segurana que so conhecidos como sendo eficazes no momento da
fabricao. possvel, para pessoas com pretenses criminais, desenvolver tcnicas que reduzam a
eficcia destes recursos. importante que um sistema de segurana seja revisado periodicamente para
garantir que os seus recursos permaneam eficazes e que sejam atualizados ou substitudos, se forem
encontrados de forma que no ofeream a proteo esperada.
Os intrusos podem entrar atravs de um ponto de acesso no protegido, evitando um dispositivo sensor,
esquivando-se de deteco pela movimentao atravs de uma rea de cobertura insuficiente,
desconectando um dispositivo de aviso ou interferindo ou evitando a operao adequada do sistema.
Falha de Energia
Os transmissores remotos deste sistema foram projetados para oferecer vrios anos de vida de bateria
sob condies normais. A vida esperada da bateria uma funo do ambiente do dispositivo, utilizao
e tipo. As condies ambientais, tais como alta umidade, alta ou baixa temperatura ou grandes
flutuaes de temperatura, podem reduzir a vida esperada da bateria. Enquanto cada dispositivo
transmissor tem um monitor de bateria baixa, o qual identifica quando as baterias necessitam ser
substitudas, este monitor pode falhar para operar como esperado. Teste e manuteno regulares
mantero o sistema em boas condies operacionais.
Os sinais podem no alcanar o receptor sob todas as circunstncias as quais poderiam incluir objetos
de metal posicionados sobre ou prximos do caminho do rdio ou considerar bloqueio ou outra
interferncia do sinal de rdio por inadvertncia.
Usurios do Sistema
Detectores de Fumaa
Os detectores de fumaa, que so uma parte deste sistema, podem no alertar adequadamente os
ocupantes de um incndio por vrias razes, algumas das quais citadas a seguir. Os detectores de
fumaa podem no ter sido instalados ou posicionados adequadamente. A fumaa pode no ser capaz
de alcanar os detectores de fumaa, tal como quando o fogo est em uma chamin, paredes ou
telhados, ou do outro lado de portas fechadas. Os detectores de fumaa podem no detectar a fumaa de
incndios em um outro pavimento da residncia ou do prdio.
Cada incndio diferente na quantidade de fumaa produzida e na proporo da queima. Os detectores
de fumaa podem no detectar igualmente bem todos os tipos de fogo. Os detectores de fumaa podem
no proporcionar aviso em tempo de incndios causados por imprudncia ou riscos de segurana, tais
como fumar na cama, exploses violentas, escape de gs, estocagem inadequada de materiais
inflamveis, circuitos eltricos sobrecarregados, crianas brincando com fsforos ou incndio culposo.
Mesmo se o detector de fumaa operar como planejado, pode haver circunstncias quando h aviso
insuficiente para permitir que todos os ocupantes escapem em tempo para evitar leses ou morte.
Detectores de Movimento
Os detectores de movimento podem detectar movimento somente dentro das reas designadas, como
mostrado nas suas respectivas instrues de instalao. Eles no podem discriminar entre intrusos e
ocupantes internos. Os detectores de movimento no oferecem proteo da rea volumtrica. Eles tm
mltiplos feixes de deteco e o movimento pode somente ser detectado em reas no obstrudas
cobertas por estes feixes. Eles no podem detectar movimento que ocorre atrs das paredes, tetos, pisos,
portas fechadas, parties de vidro, portas ou janelas de vidro. Qualquer tipo de violao, seja
intencional ou no-intencional, tais como mascaramento, pintura ou borrifao de qualquer material nos
sensores, espelhos, janelas ou qualquer outra parte do sistema de deteco, prejudicar sua operao
adequada.
Os detectores de movimento com infravermelho passivo operam detectando alteraes na temperatura.
Entretanto, a sua eficcia pode ser reduzida quando a temperatura ambiente aumentar para prximo ou
acima da temperatura do corpo ou se houver fontes de calor intencionais ou no-intencionais dentro ou
prximas da rea de deteco. Algumas destas fontes de calor poderiam ser aquecedores, radiadores,
estufas, churrasqueiras, lareiras, luz solar, vaporizadores, iluminao, etc.
Dispositivos de Aviso
Os dispositivos de aviso, tais como sirenes, buzinas ou luzes estroboscpicas podem no avisar ou
acordar algum que esteja dormindo, se houver interveno de uma parede ou porta. Se os dispositivos
de aviso estiverem localizados em um nvel diferente da residncia ou do prdio, ento, menos
provvel que os ocupantes sejam alertados ou acordados. Os dispositivos de aviso audveis podem ser
interferidos por outras fontes de rudo, como estreos, rdios, televisores, ares-condicionados ou outros
equipamentos ou trfego passante. Os dispositivos de aviso audveis, mesmo altos, podem no ser
ouvidos por uma pessoa com deficincia auditiva.
Linhas Telefnicas
Se as linhas telefnicas forem utilizadas para transmitir alarmes, elas podem estar fora de servio ou
ocupadas por certos perodos de tempo. Outrossim, um intruso pode cortar a linha telefnica ou anular
sua operao por meios mais sofisticados, os quais podem ser difceis de serem detectados.
Tempo Insuficiente
Pode haver circunstncias, quando o sistema ir operar como planejado, em que os ocupantes no
seriam protegidos de emergncia devido sua inabilidade de responder aos avisos em tempo. Se o
sistema for monitorado, a resposta pode no ocorrer em tempo para proteger os ocupantes ou os seus
pertences.
Falha de Componente
Embora todo esforo tenha sido feito para fazer este sistema to confivel quanto possvel, o sistema
pode falhar para funcionar como planejado devido falha de um componente.
Teste Inadequado
A maioria dos problemas, que evitariam um sistema de alarme de operar como planejado, pode ser
encontrada pelo teste e manuteno regulares. O sistema completo dever ser testado semanalmente e
imediatamente aps uma interrupo, uma interrupo intencional, um incndio, uma tempestade, um
terremoto, um acidente ou qualquer tipo de atividade de construo dentro ou fora das instalaes. O
teste dever incluir todos os dispositivos sensores, teclados, consoles, dispositivos que indicam alarme
e quaisquer outros dispositivos operacionais que fazem parte do sistema.
Segurana e Seguro
GARANTIA LIMITADA
A Digital Security Controls (DSC) garante ao comprador original que, por um perodo de doze meses a
partir da data de compra, o produto dever estar livre de defeitos de materiais e de mo-de-obra sob
utilizao normal. Durante o perodo de garantia, a Digital Security Controls ir, por opo sua, reparar
ou substituir qualquer produto defeituoso mediante devoluo do produto sua fbrica, sem nenhum
custo de mo-de-obra e materiais. Qualquer substituio e/ou partes reparadas so garantidas pelo
tempo remanescente da garantia original ou noventa (90) dias, qual durar mais. O proprietrio original
deve notificar prontamente a Digital Security Controls, por escrito, que h defeito no material ou na
mo-de-obra; tal notificao escrita dever ser recebida, em todos os eventos, antes da expirao do
perodo de garantia.
Garantia Internacional
A garantia para clientes internacionais a mesma como para qualquer cliente dentro do Canad e dos
Estados Unidos, com a exceo que a Digital Security Controls no dever ser responsvel por
quaisquer despesas de clientes, taxas ou VAT que possam ser devidas.
Procedimento de Garantia
Para obter servio sob esta garantia, favor devolver o(s) item(ns) em questo ao ponto de venda. Todos
os distribuidores e revendedores autorizados tm um programa de garantia. Qualquer pessoa que
devolve bens Digital Security Controls deve, primeiro, obter um nmero de autorizao. A Digital
Security Controls no aceitar nenhuma remessa que no tenha tido uma autorizao prvia.
Esta garantia aplica-se somente aos defeitos em partes e de mo-de-obra relativas utilizao normal.
Ela no cobre:
danos decorrentes de transporte ou manuseio;
danos causados por desastre, tais como incndio, inundaes, ventos, terremotos ou relmpagos;
danos devido a causas fora do controle da Digital Security Controls, tais como tenso excessiva,
choque mecnico ou danos com gua;
danos causados por adaptaes, alteraes, modificaes no-autorizadas ou objetos estranhos;
danos causados por perifricos (a menos que tais perifricos sejam fornecidos pela DSC);
defeitos causados por falha em proporcionar um ambiente adequado de instalao para os produtos;
danos causados por uso de produtos para objetivos diferentes daqueles para os quais ele foi projetado;
danos por manuteno inapropriada;
danos que surgem de qualquer outro abuso, mau trato ou aplicao indevida dos produtos.
A responsabilidade da Digital Security Controls por falha em reparar o produto sob esta garantia aps
um nmero razovel de tentativas ser limitada a uma substituio do produto, como a nica soluo
por violao da garantia. Sob circunstncia alguma a Digital Security Controls ser responsvel por
quaisquer danos especiais, incidentais ou conseqenciais baseados na violao da garantia, violao do
contrato, negligncia, responsabilidade estrita ou qualquer outra teoria legal. Tais danos incluem, mas
no so limitados a, perda de proveitos, perda do produto ou de qualquer equipamento associado, custo
de capital, custo do equipamento substitudo, recursos ou servios, tempo parado, tempo do comprador,
reclamaes de terceiros, incluindo clientes, e prejuzos propriedade.
Esta garantia contm a garantia completa e dever estar no lugar de quaisquer e todas as outras
garantias, expressas ou implcitas (incluindo todas as garantias implcitas de comerciabilidade ou
adequao a um objetivo em especial), e de todas as outras obrigaes ou responsabilidades por parte
da Digital Security Controls. A Digital Security Controls no assume nenhuma responsabilidade nem
autoriza qualquer outra pessoa que pretenda agir em seu nome para modificar ou alterar esta garantia,
nem para assumir por ela qualquer outra garantia ou responsabilidade referente a este produto. Esta
renncia das garantias e garantia limitada so controladas pelas leis da provncia de Ontrio, Canad.
AVISO: A Digital Security Controls recomenda que o sistema inteiro seja completamente testado
regularmente. No entanto, apesar do teste freqente e devido, mas no limitado a, violao criminal ou
interrupo eltrica, possvel que este produto falhe ao realizar o planejado.
Bloqueio do Instalador
Quaisquer produtos devolvidos DSC, que tiver a opo de Bloqueio do Instalador habilitada e no
exibir nenhum outro problema, estaro sujeitos a um custo de servio.
A Digital Security Controls Ir, por opo sua, reparar ou substituir os produtos fora de garantia, os
quais forem devolvidos sua fbrica, de acordo com as seguintes condies. Qualquer pessoa que
devolve bens Digital Security Controls deve, primeiro, obter um nmero de autorizao. A Digital
Security Controls no aceitar nenhuma remessa que no tenha tido uma autorizao prvia.
Os produtos que a Digital Security Controls determina como sendo reparveis, sero reparados e
devolvidos. Uma taxa estabelecida, a qual a Digital Security Controls predeterminou e que pode ser
revisada de tempos em tempos, ser cobrada para cada unidade reparada.
Os produtos que a Digital Security Controls determina como no sendo reparveis, sero substitudos
pelo produto equivalente mais prximo disponvel naquele momento. O preo de mercado atual do
produto de substituio ser cobrado para cada unidade de substituio.
IMPORTANTE - LEIA COM ATENO: O software DSC, adquirido com ou sem Produtos e Componentes, respeita leis de direitos
de autor e comprado com a aceitao dos seguintes termos de licenciamento:
Qualquer software fornecido com o PROGRAMA que esteja associado a um contrato de licena de
utilizador final em separado est licenciado a V. Exa. nos termos desse mesmo contrato de licena.
(g)
Marcas Registadas - Este CLUF (EULA) no concede a V.Exa. quaisquer direitos em relao
a quaisquer marcas registadas ou de servio da DSC ou seus fornecedores.
3. DIREITOS DE AUTOR.
Todos os ttulos e direitos de propriedade intelectual no e para o PROGRAMA (incluindo, mas no
limitando, quaisquer imagens, fotografias e texto incorporado no PROGRAMA), os materiais impressos
que o acompanham ou quaisquer cpias do PROGRAMA, so propriedade da DSC ou dos seus
fornecedores. V.Exa. no poder copiar os materiais impressos que acompanham o PROGRAMA. Todos os
ttulos e direitos de propriedade intelectual no e para o contedo que poder vir a ser acedido atravs do
uso do PROGRAMA so propriedade dos respectivos proprietrios do contedo e podero ser protegidos
por direitos de autor aplicveis ou outros tratados e leis de propriedade intelectual. Este CLUF (EULA) no
confere a V.Exa. quaisquer direitos sobre o uso desses contedos. A DSC e os seus fornecedores reservam
todos os direitos no expressos ao abrigo deste CLUF (EULA) .
4. RESTRIES EXPORTAO.
V.Exa. assume que no exportar ou reexportar o PROGRAMA para qualquer pas, individuo ou entidade
sujeito a restries de exportao Canadianas.
5. LEGISLAO APLICVEL:
Este Acordo de Licena de Software regido pelas leis da Provncia de Ontrio, Canada.
6. ARBITRAGEM
Todos os conflitos emergentes da relao com este Acordo sero determinados por arbitragem final e
mandatria ao abrigo do Arbitration Act, ficando as partes sujeitas deciso arbitral. O local designado para
a arbitragem ser Toronto, no Canada, e a lngua utilizada na arbitragem ser o Ingls.
7. LIMITES DE GARANTIA
(a) ISENO DE GARANTIA
A DSC FORNECE O SOFTWARE TAL COMO EST SEM GARANTIA. A DSC NO GARANTE QUE O
SOFWARE IR AO ENCONTRO DOS SEUS REQUISITOS OU QUE O FUNCIONAMENTO DO SOFTWARE
SEJA ININTERRUPTO OU LIVRE DE ERROS.
(b) ALTERAES AO AMBIENTE OPERATIVO
A DSC no se responsabiliza por problemas causados por alteraes s caractersticas operativas do
HARDWARE, ou por problemas na interaco do PROGRAMA com SOFTWARE ou HARDWARE no
produzido pela DSC.
(c) LIMITAES DE RESPONSABILIDADE; A GARANTIA REFLECTE A ALOCAO DE RISCO
EM QUALQUER CASO, SE ALGUM ESTATUTO IMPLICAR GARANTIAS OU CONDIES NO
MENCIONADOS NESTE ACORDO DE LICENA, A RESPONSABILIDADE TOTAL DA DSC NO SER
SUPERIOR AO VALOR EFECTIVAMENTE PAGO POR V.EXA. PELA LICENA DESTE PROGRAMA E CINCO
DOLARES CANADIANOS (CAD$5.00). PORQUE ALGUMAS JURISDIES NO PERMITEM A EXCLUSO
OU LIMITAO DE RESPONSABILIDADE PARA DANOS CONSEQUENTES OU ACIDENTAIS, A LIMITAO
ACIMA INDICADA PODER NO SE APLICAR A V.EXA..
(d) ISENO DE GARANTIAS
ESTA GARANTIA CONTM A GARANTIA COMPLETA E DEVER PREVALECER SOBRE TODA E
QUALQUER GARANTIA, EXPRESSA OU IMPLICITA (INCLUINDO TODAS AS GARANTIAS DE
COMERCIALIZAO OU ADAPTAO PARA UM DETERMINADO FIM.) E A TODAS AS OUTRAS
OBRIGAES OU RESPONSABILIDADES POR PARTE DA DSC. A DSC NO D QUAISQUER OUTRAS
GARANTIAS. A DSC NO ASSUME NEM AUTORIZA QUALQUER OUTRA PESSOA A AGIR EM SEU NOME
NA MODIFICAO DESTA GARANTIA, NEM PARA QUE POSSA ASSUMIR POR SI (DSC) QUALQUER
OUTRA GARANTIA OU RESPONSABILIDADE RELACIONADA COM ESTE PROGRAMA.
(e) DIREITOS EXCLUSIVOS E LIMITAO DE GARANTIA
EM NENHUMA CIRCUNSTNCIA SER A DSC RESPONSABILIZADA POR QUAISQUER DANOS
ESPECIAIS, ACIDENTAIS, CONSEQUENTES OU INDIRECTOS RESULTANTES DE FALHAS NA GARANTIA,
FALHAS NO CONTRATO, NEGLIGNCIA, RESPONSABILIDADE OBJECTIVA, OU QUAISQUER OUTRAS
TEORIAS LEGAIS. TAIS DANOS INCLUM, MAS NO LIMITAM, PERDA DE LUCROS, PERDA DO
PROGRAMA OU EQUIPAMENTO ASSOCIADO, CUSTO DE CAPITAL, CUSTOS COM EQUIPAMENTO DE
SUBSTITUIO, INSTALAES OU SERVIOS, TEMPO MORTO, TEMPO DE COMPRA, EXIGNCIAS DE
TERCEIROS, INCLUINDO CLIENTES, E PREJUZO SOBRE A PROPRIEDADE.
ATENO: A DSC recomenda que todo o sistema seja completamente testado numa base de
regularidade. Contudo, e apesar da testagem frequente, e devido a, mas no limitando,
comportamento criminoso ou falha elctrica, possvel que este PROGRAMA possa no
funcionar como esperado.
As marcas comerciais, logotipos e marcas de servio exibidos neste documento esto registrados nos Estados Unidos (ou outros pases). Qualquer uso inadequado das marcas comerciais
estritamente proibido e a Tyco International Ltd. ir aplicar agressivamente todos os seus direitos de propriedade intelectual at o limite da lei, incluindo a representao de ao criminal sempre
que necessrio. Todas as marcas comerciais que no sejam de propriedade da Tyco International Ltd. pertencem aos seus respectivos proprietrios e so utilizadas com permisso ou em
conformidade com as leis aplicveis.
As ofertas e especificaes de produtos esto sujeitas a mudana sem aviso prvio. Os produtos reais podem variar em relao s fotos. Nem todos os produtos incluem todas as caractersticas. As
disponibilidades variam por regio; entre em contato com o seu representante de vendas.