Escolar Documentos
Profissional Documentos
Cultura Documentos
201-Durabilidade de Estruturas de Concreto PDF
201-Durabilidade de Estruturas de Concreto PDF
Abstract
The durability of concrete structures is dependent on a series of requirements for design,
construction and maintenance practices. However, these requirements are not an easy task.
For example, the maintenance that must be undertaken regularly and its efficiency depend
on the correct selection and implementation of conservation and repair techniques. This
paper presents the consequences of an ineffective maintenance practice of two reinforced
concrete piers exposed to a marine environment. One of the piers was built recently (New
Pier) and the other one existes for over 40 year (Old Pier). In both piers, pathological
manifestations were observed, most of them being investigated in futher testing. In the Old
Pier, the original concrete as well the repaired concrete, frequently presented manifestations
related to corrosion of the reinforced steel, a process confirmed by the results of tests of
potencial and corrosion rate and the achievement of critical levels of chloride near the bar.
The the New Pier presented construction problems, and it was an early profile of
penetration of chlorides in the concrete cover.
Resumo
A durabilidade das estruturas de concreto dependente do atendimento de uma srie de
requisitos de projeto, execuo e manuteno. No entanto, este atendimento no uma
tarefa fcil, como exemplo a manuteno que tem de ser realizada periodicamente e tem sua
eficincia dependente da correta seleo e execuo das tcnicas de conservao e
recuperao. Neste trabalho, so apresentadas as conseqncias da ausncia de uma
manuteno peridica eficiente em estruturas de concreto expostas ao ambiente marinho,
com base na avaliao do estado de conservao de dois peres: um existente h mais de 40
anos (Per Velho) e outro recm-construdo (Per Novo). Em ambos os peres,
manifestaes patolgicas foram observadas, sendo parte delas investigadas em ensaios
complementares. No Per Velho, tanto no concreto original como recuperado era freqente
a presena de anomalias relacionadas corroso, processo este confirmado pelos resultados
de ensaios de potencial e taxa de corroso e pela obteno de teores crticos de cloreto na
armadura. No Per Novo, era frequente a presena de falhas construtivas, tendo-se um
incio de perfil de penetrao de cloretos no concreto de cobrimento.
Palavras-chave: corroso ambiente marinho, per, concreto armado e medidas
eletroqumicas.
1
Mestre em Habitao: Tecnologia das Construes, Pesquisadora do Laboratrio de Corroso e Proteo
do Instituto de Pesquisas Tecnolgicas IPT (e-mail: aaraujo@ipt.br).
2
Doutora em Cincias, Responsvel pelo Laboratrio de Corroso e Proteo do Instituto de Pesquisas
Tecnolgicas IPT (e-mail: zep@ipt.br).
INTERCORR2010_349
1. Introduo
Neste trabalho, so apresentados os resultados da avaliao do estado de conservao de
dois peres, um existente h mais de 40 anos (denominado neste trabalho como Per Velho)
e outro recm-construdo (denominado neste trabalho como Per Novo).
Os trabalhos foram iniciados com o reconhecimento do local, sendo realizada uma inspeo
visual preliminar das estruturas de ambos os peres e uma anlise tanto da documentao
tcnica disponvel como das condies de exposio local. Com base nos resultados
obtidos, as principais atividades realizadas foram as seguintes:
inspeo visual detalhada da estrutura principal dos peres;
ensaios em campo e em laboratrio para a determinao da profundidade de
carbonatao e do teor de cloreto e de parmetros eletroqumicas e para a
caracterizao do concreto;
anlise dos resultados e concluso e recomeno de conservao das estruturas.
2. Reviso bibliogrfica
Em ambiente marinho, as estruturas de concreto esto sujeitas corroso pela penetrao
externa de ons cloreto no concreto de cobrimento. Esta penetrao ocorre devido
constante presena de nvoa salina na atmosfera, a qual a condio mais caracteristica do
ataque de cloretos neste ambiente. Alm desta condio de exposio, destaca-se o contato
direto do concreto com a gua do mar e suas ondas e respingos, que ocorre em estruturas
localizadas beira mar, como peres.
Perante essas condies de exposio, o ambiente marinho apresentado na NBR 12655
(1) como uma condio especial, sendo que, na NBR 6118 (2), este ambiente classificado
como de agressividade forte a muito forte s estruturas de concreto. Em tal agressividade,
as normalizaes estabelecem alguns parmetros para a obteno de um concreto de
qualidade, como os descritos na Tabela 1.
Em funo da alta agressividade, h uma constante preocupao quanto durabilidade das
estruturas de concreto no ambiente marinho. Considerando que a deteriorao da estrutura
pode ocorrer em curto intervalo de tempo, a estratgia mais apropriada para este ambiente
seria adotar um concreto de qualidade e tambm uma proteo (3). Isto porque, em
ambiente contaminado com cloretos, dificilmente uma adequada durabilidade garantida
somente com a especificao das caractersticas do concreto, como resistncia,
porcentagem de cimento e relao gua/cimento (4).
A mencionada proteo reconhecida com uma tcnica que pode garantir e estender a vida
til das estruturas. No Brasil, a nica tcnica disseminada a proteo superficial do
concreto com revestimentos por pintura ou por argamassa cimentcia, os quais, no exterior,
tm normalizao especfica para seleo e controle da qualidade de aplicao, como as
Partes 2, 3 e 10 da BS EN 1504 (5-7). Outra tcnica bastante disseminada, embora de uso
restrito e pouco estudada no Brasil, a proteo catdica. Como referncia de
normalizao, cita-se a NACE SP0290 (8) para aplicao de sistema de corrente impressa e
a NACE 01105 (9) para sistema de proteo galvnica.
Dentre outros parmetros relacionados durabilidade das estruturas de concreto, destaca-se
a importncia da manuteno peridica da edificao como um todo. No entanto, segundo a
NBR 5674 (10), frequente a sua omisso nas edificaes brasileiras, como pontes e
-2-
INTERCORR2010_349
-3-
INTERCORR2010_349
neoprene como aparelho de apoio. Este ltimo tipo de aparelho tambm adotado no Per
Novo, a cada seis vos.
O Per Novo no sofreu nenhuma interveno deste a sua construo, enquanto, em 1993, o
Per Velho teve a sua primeira grande manuteno de recuperao, sendo a maioria das
estacas da Ponte de Acesso encamisada por apresentavam anomalias relacionadas
corroso. A mesmo interveno foi feita nos demais elementos desta estrutura e na do Per
de Atracao 1 em 1998. Com base nestes dados e considerando que a fissurao de
corroso no concreto de cobrimento ocorre, geralmente, aps 10 anos do seu incio (12), a
despassivao da armadura no Per Velho ocorreu, provavelmente, antes de 1985. Nesta
hiptese, a vida til de projeto da estrutura foi esgostada em torno 20 anos da sua
construo.
A documentao disponvel tambm aponta a ocorrncia de muitas intervenes de
recuperao e reforo devido ocorrncia de acidentes, tendo-se o maior deles ocorrido no
Per de Atracao 2. Alm da recuperao geral de grande trecho desta estrutura, o projeto
apontou a substituio de parte das vigas protendidas.
-4-
INTERCORR2010_349
tambm colabora para a secagem do concreto e, ao longo dos anos, com o seu desgaste
superficial;
insolao: em clima tropical, os raios solares podem elevar bastante a temperatura
ambiente e, tambm, a temperatura superficial do concreto, reduzindo o grau de sua
umidade. Cita-se que a umidade relativa na regio oscila bastante, sendo estimado que
durante o dia, esteja entre 60 % e 75 % o que superado no perodo noturno. A
temperatura ambiente oscila em torno de 15 o C (julho) e de 39 o C (janeiro);
condensao da gua: gotculas de gua podem se depositar na superfcie da face
inferior dos elementos das estruturas, o que ocorre de forma mais intensa nos
elementos de maior prximidade ao mar. Neste caso, e considerando que na face
inferior no h incidncia direta de raios solares e h pouca ao do vento, pode ser
estabelecido facilmente um microclima adequado para a manuteno da umidade
superficial, o que acelera a penetrao de cloretos e o desenvolvimento de fungos e de
limo;
carbonatao: sabido que as reaes qumicas entre o dixido de carbono e
compostos do cimento reduz o pH do concreto de cobrimento, sendo que, quando esta
reduo atinge a armadura, h condies para a sua despassivao e o incio de um
processo corrosivo. Este fenmeno, denominado carbonatao, ocorre em velocidade
significativa quando o concreto se mantm mido, entre teores de 50 % a 75 % (13).
Em ambiente marinho, estes teores so comuns no concreto dos elementos mais
sujeitos insolao e ao vento. No entanto, na proximidade ao mar, so esperados
perodos longos de manuteno da umidade superficial do concreto, em teores
superiores aos descritos.
4. Metodologia
4.1 Inspeo visual
A inspeo visual consistiu do exame, a olho desarmado, da parte inferior exposta da
estrutura principal de cada um dos peres, exclundo as estacas metlicas. Para tanto, foi
utilizada uma embarcao, sendo que no perodo de mar-baixa era priorizado o exame da
infra-estrutura e, o de mar-alta, o da superestrutura.
Embora a inspeo visual tenha sido feita ao longo de toda a extenso dos peres, a
concepo da estrutura principal, com muitos vos idnticos, permitiu adotar uma
metodologia em que somente alguns deles, com anomalias representativas, fossem
examinados detalhadamente. Para tanto, era feito, alm do registro e a quantificao das
anomalias, um registro fotogrfico e elaborados croquis. Tais determinaes e muitas das
outras definidas no presente estudo foram feitas com base nos termos de contrato do
trabalho, no Anexo A na NBR 9452 (14), bem como na experincia das pesquisadoras.
Para o exame visual, foi considerada a verificao na inspeo preliminar, da necessidade
de tratamento superficial geral da superfcie do concreto das estruturas, incluindo a
remoo das pinturas (tinta preta betuminosa e amarela alqudica), consideradas
inadequadas como proteo superficial do concreto. Esta pintura estava presente na
estrutura da Ponte de Acesso, Per de Atracao 2 e parte do Per de Atracao 1. O exame
tambm considerou a identificao dos tipos de anomalias existentes nas estruturas durante
-5-
INTERCORR2010_349
a inspeo preliminar. A Tabela 2 foi elaborada com base nessa identificao e a consulta
ao Glossrio Tcnico da empresa Maubertec (15).
-6-
INTERCORR2010_349
diferentes extraes. Nestas, foi determinado o teor de ons cloreto solveis em gua
conforme ASTM C 1218 (17) e expresso em relao massa de cimento.
Os resultados obtidos foram avaliados para verificar a probabilidade de ocorrncia da
despassivao da armadura e para determinar o perfil da profundidade de penetrao no
concreto de cobrimento. Para tal avaliao, foram adotados os valores limites de teores de
cloreto apresentados na Tabela 1, os quais so similares aos apresentados pelo Building
Code 318 (18), que define a concentrao limite de teor de cloreto de 0,15 % sobre a massa
do cimento em concreto armado e 0,06 % em concreto protendido.
Com base no estudo dos projetos das estruturas, foram marcados nos elementos
selecionados alguns estribos e uma a duas das barras principais de sua armadura, sendo
sempre priorizada a regio de quinas entre faces, a qual est mais exposta ao agressiva
do ambiente. Como a grade formada pela a armadura no era uniforme e, ainda, havia
limitaes de trabalho no local, as medidas eletroqumicas foram feitas sem uma seqncia
lgica. Para tanto, foram estabelecidos e numerados pontos nas barras e dos estribos,
evitando locais de seu cruzamento. Nas Figuras 2 a 4 e nas Figuras 5 a 7 so apresentados
desenhos esquemticos da grade da armadura com os pontos de medio na Ponte de
Acesso e no Per Novo respectivamente. Na Figura 8, pode-se visualizar a grade em alguns
elementos.
Antes da marcao, a superfcie do concreto foi tratada para limpeza e remoo de
revestimentos e de resduos de concreto. Na Ponte de Acesso e no Per de Atracao 2, o
tratamento consistiu da remoo manual de uma grossa camada de tinta betuminosa e,
posteriormente, lixamento mecnico. No Per de Atracao 1 e no Per Novo, o tratamento
consistiu somente de um lixamento mecnico para limpeza superficial.
Em um trecho exposto e limpo da armadura foi fixado o terminal do equipamento (jacar)
do Gecor 8 para estabelecer contato eltrico, o qual tinha sua eficincia verificada com uso
de um multmetro. Tambm antes da medio, a superfcie do concreto era umidecida com
pulverizao manual de gua potvel por perodo de trinta minutos. Caso durante a medio
fosse observada a secagem superficial do concreto, novas pulverizaes eram realizadas.
Na Figura 9, pode-se visualizar a realizao de medio no Per Velho.
5. Resultados e discusso
5.1 Inspeo visual
A inspeo visual da Ponte de Acesso e do Per de Atracao 1 do Per Velho apontou um
estado avanado de degradao da sua estrutura principal. Nesta, foi observada a presena
constante de reas localizadas de concreto disgregado com armadura exposta (em estado
avanado de corroso) nas vigas, em destaque na sua face inferior e quinas com as faces
laterais. Nestas vigas e nas estacas, tambm era frequente a presena de intervenes de
recuperao consideradas inadequadas, estando a grande maioria das estacas encamisadas.
-8-
INTERCORR2010_349
Na face inferior das vigas transversais, ainda era expressiva a presena de concreto
segregado (na regio de engaste) e, nas laterais das vigas longitudinais, de fissurao
vertical eqidistante, cuja causa provvel seria a retrao do concreto. Como somente parte
destas fissuras estava recuperada, foi suposto que parte ocorreu, posteriormente, tendo
como causa o travamento dos aparelhos de apoio que se apresentavam com intensa
corroso. Devido presena de corroso e de outras anomalias na regio destes aparelhos e,
ainda, anomalias nos revestimentos de acabamento, no sistema de drenagem de gua fluvial
e nas juntas de dilatao, todos estes foram considerados inadequados. Sobre os
revestimentos, frequentemente, eram observadas manchas e algumas reas superficiais
localizadas de concreto segregado e de porosidade superficial (vazios de bolhas de ar
aprisionado). Nas Figuras 10 e 11, podem-se visualizar algumas destas anomalias.
A inspeo do Per de Atracao 2 apontou tambm a presena de anomalias similares s
descritas para as outras estruturas do Per Velho. No entanto, era preocupante a presena de
fissurao sistemtica nas vigas longitudinais protendidas, sendo parte delas sobre os
revestimentos de reparo, considerados tambm ineficientes. Nestas vigas, ainda havia reas
localizadas de concreto disgregado com armadura corroda, algumas com exposio de
bainhas de protenso. Na Figura 12, podem-se visualizar algumas destas anomalias.
Embora a inspeo do Per Novo no apontasse o estabelecimento de um processo
corrosivo, frequentemente observou-se, ao longo da estrutura, anomalias relacionadas a
falhas construtivas. A presena de fissurao sistemtica ao longo das vigas longitudinais
era a anomalia mais significativa, sendo parte destas (fissuras verticais equidistantes)
julgada como resultante da retrao do concreto e, outra parte (fissuras verticais
concentradas na regio de mximo momento fletor), resultante da flexo prematura das
vigas, possivelmente durante transporte. Alm disto, tambm era freqente nestas vigas e
nas transversais, a presena de reas localizadas de manchas de eflorescncias e umidade
(com acmulo de limo e fuligem), de porosidade superficial e de concreto segregado e,
ainda, a presena de material residual de formas de concretagem e furos remanescentes de
sua fixao. Nas estacas, era comum a presena de manchas localizadas de umidade, e de
oxidao e de incrustaes. Na Figura 13, podem-se visualizar algumas destas anomalias.
De forma geral, em ambos os Peres havia uma tendncia de concentrao de manchas em
regio de acmulo de gua de escorrimento e de condensao e de gua de infiltrao (rede
de drenagem e juntas de dilatao). Na regio de falhas de execuo, tambm era comum a
concentrao de manchas em destaque fissurao e concreto segregado. Estes dois tipos de
anomalias tambm estavam presentes em ambos os peres, sendo similar a configurao da
fissurao nas vigas longitudinais de concreto armado e, a localizao das reas de concreto
segregado, comum nos engastes das estacas, nas quinas das faces das vigas e na unio de
tbuas de formas de concretagem.
-9-
INTERCORR2010_349
- 10 -
INTERCORR2010_349
- 12 -
INTERCORR2010_349
6. Concluses
As concluses principais quanto s condies ambientais que as estruturas dos peres esto
expostas so as seguintes:
a anlise do ambiente local (Item 3.2) indicou que as estruturas esto sujeitas uma
condio especial de exposio, sendo o ambiente classificado de agressividade muito
forte, conforme as normalizaes nacionais mencionadas (NBR 6118 e NBR 12655);
a inspeo visual (Item 5.1) indicou como crtica a exposio nvoa salina, associada
tanto aos respingos como gua de condensao e/ou ao acmulo ou infiltrao da
gua pluvial contaminada. Os locais mais caracteristicos desta exposio so: topo das
estacas, quinas entre faces e face inferior das vigas, juntas de dilatao e rede de
drenagem. Destes locais, cita-se a estaca como sendo o elemento mais crtico para a
corroso, conforme indicou o histrico de intervenes (Item 3.1) no Per Velho.
No Per Velho, a inspeo visual e os ensaios complementares indicaram, claramente, a
avanada deteriorao das estruturas, estando a sua durabilidade comprometida. As
concluses principais do estudo deste Per so as seguintes:
a inspeo visual (Item 5.1) indicou a presena de diversas anomalias ao longo das
estruturas, muitas delas devido corroso da armadura por ataque de ons cloreto. A
corroso era crtica na armadura aparente em reas localizadas do concreto e tambm
em reas com bainhas e cabos de protenso aparentes em algumas vigas longitudinais
do Per de Atracao 2. A corroso tambm era crtica nos aparelhos de apoio;
a inspeo visual indicou que as anomalias estavam relacionadas no somente
agressividade local do ambiente (Item 3.2), com tambm a falhas de execuo,
- 13 -
INTERCORR2010_349
- 14 -
INTERCORR2010_349
8. Referncias bibliogrficas
- 15 -
INTERCORR2010_349
6. ________. BS EN 1504-3: products and systems for the protection and repair of concrete
structures: definitions, requirements, quality control and evaluation of conformity:
structural and non-structural repair. British Standards Institution. London, 2005.
7. ________. BS EN 1504-10: products and systems for the protection and repair of concrete
structures: definitions, requirements, quality control and evaluation of conformity: site
application of products and systems and quality control of the works. British Standards
Institution. London, 2005.
8. NACE - NACE INTERNATIONAL. NACE STANDART SP0290: impressed current
cathodic protection of reinforcing. Nace International. Houston, 2005. 12p.
9. NACE - NACE INTERNATIONAL. NACE STANDART SP1105: sacrificial cathodic
proctection of reinforced concrete elements: a state-of-the-art report. Nace International.
Houston, 2005. 15p
10. ABNT - ASSOCIAO BRASILEIRA DE NORMAS TCNICAS. NBR 5674:
manuteno de edificaes: procedimento. ABNT. Rio de Janeiro. 1999. 6p.
11. ________. NBR 14037: manual de operao, uso e manuteno das edificaes:
contedo e recomendaes para elaborao e apresentao. ABNT. Rio de Janeiro. 1998.
5p.
12. NACE - NACE INTERNATIONAL. NACE STANDART SP0187: design
consideration for corrosion control steel in concrete. Nace International. Houston, 2008.
19p.
13. VERBECK, G.J.; LANDGREN, R. Influence of physical characteristics of aggregates
on the frost resistance of concrete. Proceedings, ASTM, West Conshohocken, Pa., v. 30,
p.1063-1079 1960 (apud ACI 201.2r, AMERICAN CONCRETE INSTITUTE. Guide to
durable concrete. In: ACI manual of concrete practice, 2001. Michigan: ACI, 2001. 41
p.)
14. ABNT - ASSOCIAO BRASILEIRA DE NORMAS TCNICAS. NBR 9452: vistoria
de pontes e viadutos de concreto. ABNT. Rio de Janeiro. 1986. 13p.
- 16 -
INTERCORR2010_349
- 17 -
INTERCORR2010_349
27. JAMES INSTRUMENTS. The Gecor 8 corrosion rate meter: instruction manual.
James Instruments S.A. Chicago, USA, 2002. 2ed. 83 p.
28. ABNT - ASSOCIAO BRASILEIRA DE NORMAS TCNICAS. NBR 5739:
Concreto: ensaio de compresso de corpos-de-prova cilndricos. Rio de Janeiro. 1994.
4p.
29. ______. NBR 9778: Argamassas e concretos endurecidos: determinao da absoro de
gua, ndice de vazios e massa especfica. Rio de Janeiro. 2005. 4p.
30. ______. NBR 7680: Extrao, preparo, ensaio e anlise de testemunhos de estruturas
de concreto: procedimento. Rio de Janeiro. 2007. 12p.
31. ARAUJO, A. Estudo para o estabelecimento de metodologia de seleo de vernizes
na proteo ao concreto armado contra a penetrao de agentes agressivos. So
Paulo, SP: IPT, 2004. 403 f. Originalmente parte do estudo foi apresentada como
dissertao de mestrado, Instituto de Pesquisas Tecnolgicas de So Paulo, 2004
(Projeto FAPESP 2001/12.256-2)
32. HELENE, P. R.L. La Agressividad del Medio y la Durabilidad del Hormign.
Hormign, AATH, n. 10 p. 25-35, ago. 1983
33. TESTANI, L. Memorial Descritivo Um guia prtico para elaborao de documentos
tcnicos. So Paulo. 2009. 96p. (referncia para os planos de ao e desenvolvimento dos
trabalhos).
AGRADECIMENTO
Os autores agradecem Pedro C. Bilesky, Srgio C. ngulo, Alessandra L. de Castro e
Valdecir A. Quarcioni, do Laboratrio de Matreiais de Cosntruo Civil do IPT, pela
realizao e anlise dos resultados dos ensaios de caracterizao do concreto.
Parmetro
Relao gua Resistncia Teor de cloreto em Espessura do
Norma cimento compresso relao massa de concreto de
ABNT (a/c) (MPa) cimento (%) cobrimento (cm)
concreto concreto concreto concreto concreto concreto concreto concreto
armado protendido armado protendido armado protendido armado protendido
NBR
6118
- 18 -
INTERCORR2010_349
TABELA 2 Descrio das anomalias e falhas na estrutura dos peres na inspeo visual dos Peres
Alterao Tpica na
Desenvolvimento
Anomalia Descrio genrica Superfcie do Localizao Tpica
Tpico
Concreto
Engastes, quinas
Concentrao Vazios na massa do
entre faces e/ou linhas
Concreto heterognea dos Falha de especificao, concreto e exposio
entre tbuas de
segregado componentes da mistura projeto e/ou execuo. e/ou concentrao de
formas e/ou juntas de
do concreto. agregados.
construo etc.
Exposio a agentes Desgaste superficial
externos como sulfatos e progressivo em que
Perda da integridade do Drenos, canaletas,
gua (pluvial, mar, so expostos
concreto por ataque bordas, variao de
Concreto lenol fretico, industrial agregados (midos
qumico, lixiviao, altas mar, juntas e/ou
desagregado e armazenada, e/ou grados) e/ou
temperaturas, eroso, unies entre pr-
contaminadas ou no) fissurao aleatria
cavitao e/ou abraso. moldados etc.
e/ou ao vento (partculas com perda da coeso
em suspenso). do concreto.
Quinas entre faces,
Ocorrncia de choque, Fissurao de trao
abas, engastes,
Perda da geometria do impacto, esmagamento por foras internas,
Concreto apoios, unies, juntas
elemento devido a foras e/ou reaes expansivas concreto lascado com
disgregado e/ou em regies de
internas e externas. de corroso ou de lcali- ou sem exposio da
falhas construtivas e
agregado. armadura.
de manuteno etc.
Visualizao das
Segregado e/ou reaes Lascamento e/ou
armaduras, bainhas e
Armadura expansivas (corroso, perda de coeso do reas de concreto
cabos de protenso
exposta lcali-agregado e ataque concreto de segregado,
insertes metlicos e/ou
de sulfato). cobrimento. disgregado e
ancoragens.
desagregado, com
Processo de corroso falhas construtivas ou
estabelecido na Colorao alterada, armadura com
Alterao da colorao do insignificante de
Mancha de armadura e/ou em outros tendo-se manchas
concreto pelo afloramento cobrimento.
oxidao elementos metlicos vermelho-marrom-
da armadura.
presentes na massa do acastanhadas.
concreto.
Aumento do teor de Colorao alterada,
umidade do concreto, por tendo-se um
reaes de escurecimento do
Mancha de Alterao da colorao
carbonatao, contato concreto, podendo
umidade superficial do concreto
com a gua (infiltrao, estar esverdeado pela
escorrimento, presena de fungos
condensao etc). e/ou limo.
Alterao da colorao
pela deposio de Percolao, infiltrao e Colorao alterada,
Mancha de
partculas (fuligem), escorrimento de gua tendo-se acmulo de
escorrimento Faces em geral, abas,
associoada ou no a contaminada. fuligem.
quinas entre faces,
mancha de umidade.
juntas de dilatao,
Colorao alterada, unies e/ou na rede
tendo-se manchas de drenagem.
Precipitao e acmulo Reaes do dixido de
Mancha de esbranquiadas e,
de sais na superfcie do carbono com compostos
eflorescncia conforme o acmulo
concreto. do cimento.
de sais,
protuberncias.
Presena de
Presena de
componentes do concreto Arraste e acmulo de
agregados midos e
Mancha de na superfcie, podendo o componentes do
compostos da pasta
lixiviao concreto estar em concreto na superfcie
de cimento na
processo de por infiltrao de gua.
superfcie.
desagregao.
- 19 -
INTERCORR2010_349
TABELA 2 Descrio das anomalias e falhas em estruturas de concreto e siglas adotadas na inspeo visual
dos Peres (continuao)
Alterao Tpica na
Desenvolvimento
Anomalia Descrio genrica Superfcie do Localizao Tpica
Tpico
Concreto
Grandes poros e
Vazios Bolhas de ar aprisionado, vazios de dimenes
Falhas de especificao,
(porosidade durante a concretagem, e de profundidade Faces laterais.
projeto e execuo.
superficial) na superfcie do concreto. variveis na
superfcie.
Fratura do concreto com Mudana de volume do
abertura e profundidade concreto e atuao de Descontinuidade local Ao longo das faces ou
varivel, bem como, cargas estruturais ou global do elemento somente na regio de
Fissura configurao: longitudinal, (retrao, tores, flexo, e manchas de maior solicitao
horizontal, vertical, movimentao eflorescncia e/ou (fissuras passantes ou
transversal, inclinada, higrotrmica, umidade e oxidao. no).
aleatria e mapeada. cisalhamento etc).
Fissura - Fratura tamponada por Deposio de partculas
Colorao alterada na
colmatada por partculas depositadas na carreadas (gua de _
abertura da fissura.
fuligem sua abertura. escorrimento e vento).
Fissura - Fratura tamponada por Colorao alterada,
Formo e lixiviao de
colmatada por sais resultantes de tendo-se manchas _
sais.
eflorescncia reaes de carbonatao. esbranquiadas.
Fissura - Colorao alterada na
Consolidao da fissura
colmatada por _ abertura da fissura e _
com produtos especficos.
injeo presena de resinas.
Fissura -
Fratura tamponada com Argamassa na
colmatada por _ _
argamassas. superfcie do concreto.
argamassa
Fissuras, manchas e
concreto disgregado e
Presena de anomalias
Falhas - segregado nas
em reas recuperadas e
intervenes argamassas, grautes
adjacncia.
e concretos de reparo
e de reforo.
Fissuras, corroso,
Falhas - Falha na especificao,
Presena de anomalias deslocamentos e
aparelho de projeto, execuo,
na regio do apoio. deformaes.
apoio manuteno e/ou Na sua rea e regio
Anomalias no entorno.
utilizao (cargas e adjacente.
Presena de alteraes e movimentaes no- Manchas de
Falhas - juntas anomalias no concreto da previstas). infiltrao,
e unies regio e no material carbonatao,
isolante. lixiviao e fissurao.
Manchas de umidade,
Presena de alteraes e
Falhas - fuligem,
anomalias na rede de
drenagem eflorescncias e
drenagem e regio.
lixiviao.
- 20 -
INTERCORR2010_349
Elementos e especificao de
projeto: tipo, resistncia do Condies de Identificao Identificao
Local
concreto (MPa), consumo de exposio Ponte de Per de
selecionado
cimento (kg/m3) e espessura caracterstica Acesso Atracao 1
de cobrimento (cm)
Engaste da _
Estaca Respingos e nvoa salina E 41 RN
3 estaca
(pr-moldada, 30 MPa, 400 kg/m e
4 cm) Regio acima da
Respingos e marolas E 41 RM _
variao de mar
Viga Longitudinal Lateral externa Intempries L 41 FE L 112 FE
(pr-moldada, 20 MPa, 350 kg/m3 e Lateral interna gua de condensao L 41 FI L 112 FI
4 cm) Inferior gua de escorrimento L 41 FCI L 112 FCI
Inferior balano T 41 IB T 112 IB
gua de escorrimento e
Inferior engaste T 41 IE T 112 IE
de condensao
Inferior central T 41 IC T 112 IC
Viga Transversal Lateral inferior
(parte inferior: pr-moldada, T 41 LB T 112 LB
3 balano
20 MPa, 350 kg/m e 4 cm. Lateral inferior Intempries e gua de
parte superior: moldada no local, T 41 LI T 112 LI
central escorrimento
30 MPa, 400 kg/m3 e 4 cm) Lateral superior
T 41 LS T 112 LS
central
Lateral superior
Intempries T 41 LE T 112 LE
engaste
Elementos e especificao de
projeto: tipo, resistncia do
Condies de Identificao
concreto (MPa), consumo de Local
exposio Per de
cimento (kg/m3), espessura de selecionado
caracterstica Atracao 2
cobrimento (cm) e relao gua
cimento (a/c)
Lateral externa Intempries L 209 FE
Viga Longitudinal
(pr-moldada e protendida, 20 MPa, gua de
Lateral interna L 209 FI
350 kg/m3, 4 cm e condensao
gua de
a/c 0,45) Inferior L 209 FCI
escorrimento
Inferior balano gua de T 209 IB
Inferior engaste escorrimento e de T 209 IE
Viga Transversal Inferior central condensao T 209 IC
(pr-moldada, 15 MPa, 350 kg/m3, Lateral inferior
4 cm e a/c 0,45) T 209 LB
balano Intempries e gua
Lateral inferior de escorrimento
T 209 LI
central
- 21 -
INTERCORR2010_349
Elementos e especificao de
projeto: tipo, resistncia do
concreto (MPa), consumo de Condies de Identificao
Local
cimento (kg/m3), espessura de exposio
selecionado Per Novo
cobrimento (cm), relao gua caracterstica
cimento (a/c) e metacaulim
(kg/m3)
Estaca Respingos e nvoa
Engaste da estaca EP 97 RN
(pr-moldada e protendida, 50 MPa, salina
469 kg/m3, 5,5 cm, Regio acima da Respingos e
EP 97 RM
a/c 0,45 e 41 kg/m3) variao de mar marolas
Lateral externa Intempries L 43 FE
Viga Longitudinal gua de
Lateral interna L 43 FI
(pr-moldada 50 MPa, 469 kg/m3, condensao
5,0 cm, a/c 0,45 e 41 kg/m3) gua de
Inferior L 43 FCI
escorrimento
Inferior balano gua de T 43 IB
Inferior engaste escorrimento e de T 43 IE
Viga Transversal Inferior central condensao T 43 IC
(parte inferior: pr-moldada, Lateral inferior
50 MPa, 469 kg/m3, 5,5 cm, a/c T 43 LB
balano
0,45 e 41 kg/m3; parte superior: Lateral inferior Intempries e gua
moldada no local, 25 MPa, T 43 LI
central de escorrimento
360 kg/m3, 5,0 cm e Lateral superior
T 43 LS
a/c 0,50) central
Lateral superior
Intempries T 43 LE
engaste
- 22 -
INTERCORR2010_349
- 23 -
INTERCORR2010_349
Cloretos Cloretos
Profundidade Solveis Solveis
Local Local
(mm)
(%) (%)
- 24 -
INTERCORR2010_349
Cloretos Cloretos
Profundidade Solveis Solveis
Local Local
(mm)
(%) (%)
- 25 -
INTERCORR2010_349
Tabela 9 - Resultados de medidas eletroqumicas na Ponte de Acesso, face lateral da viga longitudinal
Potencial Taxa
Ponto
de corroso de corroso Observaes
(P)
(mV, ECSC) (A/cm2)
1E -222 0,91 O smbolo E identifica pontos nos estribos ( 9,50 mm) na face lateral norte.
O smbolo BI identifica pontos na barra longitudinal, de quina da face lateral
2BI -207 0,72
norte com a inferior ( 25,40 mm).
3BI -296 0,43 _
7E -250 0,74 _
8BI -343 0,91 Prximo aos Pontos 8 e 9, na face inferior, h uma fissura indicando a
9E -352 1,01 disgregao do concreto.
Tabela 10 - Resultados de medidas eletroqumicas na Ponte de Acesso, face inferior da viga longitudinal
Potencial Taxa
Ponto
de corroso de corroso Observaes
(P)
(mV, ECSC) (A/cm2)
1E -239 1,32 O smbolo E identifica pontos nos estribos ( 9,50 mm) na face inferior.
O smbolo BII identifica pontos na barra longitudinal de quina com a face
2BII -219 0,58
lateral sul da viga ( 25,40 mm).
O smbolo BI identifica pontos na barra longitudinal de quina com a face
3BI -198 0,16
lateral norte da viga ( 25,40 mm).
4BII -219 0,40 _
6E -187 0,32 _
7E -193 0,66
8BII -300 0,32 A regio entre os pontos P7 e P10 local de extrao de amostras de cloreto
9BI -295 0,32 (L41 FCI).
10E -339 1,82
Prximo ao Ponto 11 finaliza-se uma fissura indicando a disgregao do
11BII -349 0,55
concreto.
12BI -338 0,42 _
- 26 -
INTERCORR2010_349
Tabela 11 Resultados de medidas eletroqumicas na Ponte de Acesso, face lateral da viga transversal
Potencial Taxa
Ponto
de corroso de corroso Observaes
(P)
(mV, ECSC) (A/cm2)
1E -290 0,21 O smbolo E identifica pontos nos estribos ( 9,50 mm).
O smbolo BII identifica pontos na barra longitudinal mais superior da face
2BII -267 0,13
lateral da viga ( 19,00 mm).
O smbolo BI identifica pontos na barra longitudinal mais inferior da face
3BI -285 0,17
lateral da viga ( 22,20 mm).
4E -272 0,12
5BII -275 0,13 A regio aps os pontos P4 e P7, local de extrao de amostras de cloreto
6BI -279 0,16 (T41 LB).
7E -313 0,44
8E -273 0,21 _
Tabela 12 Resultados de medidas eletroqumicas na Ponte de Acesso, face inferior da viga transversal
Potencial Taxa
Ponto de corroso
de corroso Observaes
(P) (A/cm2)
(mV, ECSC)
1E -211 0,13 O smbolo E identifica pontos nos estribos ( 9,50 mm).
O smbolo BI identifica pontos na barra longitudinal de quina com a face
2BI -279 0,16
lateral norte da viga ( 19,00 mm).
3E -233 0,15 A regio entre os pontos P3 e P4, prxima do local de extrao de
4BI -280 0,16 amostras de cloreto (T41 IB).
5E -362 0,19 _
6E -362 0,13 _
- 27 -
INTERCORR2010_349
7E -263 0,41
8 _ _
9 _ _
12 _ _
14 -431 0,21
15 -355 0,16 A regio entre os pontos P14 e P18, local de extrao de amostras de cloreto,
16 -361 0,21 em zona de respingo e marolas (E41 RM).
17 -351 0,50
18E -346 0,71 Ponto de mar alta (mxima).
19 -450 0,75 _
20 -380 0,71 _
22 _ _
_ _ Nos perodos de medio estes pontos estavam expostos a marolas constantes.
23
24E _ _
- 28 -
INTERCORR2010_349
Tabela 14 Resultados de medidas eletroqumicas no Per Novo, face lateral da viga longitudinal
Potencial Taxa
Ponto Resistividade
de corroso de corroso Observaes
(P) (mV, ECSC) (k/cm)
(A/cm2)
- 29 -
INTERCORR2010_349
Tabela 15 - Resultados de medidas eletroqumicas no Per Novo, face inferior da viga longitudinal
Potencial Taxa
Ponto Resistividade
de corroso de corroso Observaes
(P) (mV, ECSC) (k/cm)
(A/cm2)
- 30 -
INTERCORR2010_349
Tabela 16 Resultados de medidas eletroqumicas no Per Novo, face lateral da viga transversal
Potencial Taxa
Ponto Resistividade
de corroso de corroso Observaes
(P) (k/cm)
(mV, ECSC) (A/cm2)
4E -49 35 0,08
- 31 -
INTERCORR2010_349
Tabela 17 Resultados de medidas eletroqumicas no Per Novo, face inferior da viga transversal
Potencial Taxa
Ponto Resistividade
de corroso de corroso Observaes
(k/cm)
(P) (mV, ECSC) (A/cm2)
3E -135 26 0,02
A regio entre os pontos P3 e P5, prximo de local de
4BI -157 22 0,01
extrao de amostras de cloreto (T43 IB).
-115 25 _
5E
-73 18 _ _
6E
-174 22 _ _
7BI
-102 22 _ _
8E
-141 29 _ _
9BI
-71 17 0,01 _
10E
-82 21 0,00 _
11BI
-34 10 _ _
12E
-58 13 _ _
13BI
-21 17 _ _
14E
-21 26 _ _
15BI
16E -49 15 0,00 A regio entre os pontos P16 e P17 local de extrao de
-69 37 0,01 amostras de cloreto (T43 IC).
17BI
- 32 -
INTERCORR2010_349
Potencial Taxa
Ponto de corroso Resistividade
de corroso Observaes
(P) (mV, ECSC) (k/cm)
(A/cm2)
_ O smbolo E identifica pontos em estribos
1E -160 21
( 8,00 mm).
_ Os Pontos sem identificao corresponde a medies nas
2 -164 31
barras verticais ( 16,00 mm).
-170 28 _ _
3
-166 29 _
4 A regio entre os pontos P4 e P5, local de extrao de
5 -157 25 0,02 amostras de cloreto, em zona de respingo e nvoa (EP97 RN).
-188 23 0,00 _
6
-130 23 0,10 _
7E
-154 24 _ _
8
-120 29 _ _
9E
-160 23 _ _
10
-180 24 _ _
11
-159 49 _ _
12
192 24 _ _
13
196 19 0,01 _
14E
-121 32 _
15 A regio entre os pontos P15 e P16, local de extrao de
amostras de cloreto, em zona de respingo e marolas (EP97
16 -144 32 0,01
RM).
-192 29 _ _
17
-136 31 _ _
18
-122 20 _
19E Ponto de mar alta (mxima).
-285 23 _ _
20
-278 22 _ _
21
-252 15 _
22E Incio da exposio s marolas.
-233 49 _
23
-219 18 _
24
25E -243 26 0,01
Medio complementares feitas com mar bem mais baixa.
26 -323 21 0,01 Abaixo do ponto P28 inicia a presena de cracas na superfcie.
27 -272 24 0,00
- 33 -
INTERCORR2010_349
Vigas Longitudinais
Figura 1 Corte esquemtico da estrutura do Per Novo (a esquerda) e da Ponte de Acesso do Per Velho (a
direita)
Figura 2 Desenho esquemtico da marcao da grade da armadura da face lateral e inferior de viga
longitudinal da Ponte de Acesso para as medidas eletroqumicas
Figura 3 Desenho esquemtico da marcao da grade da armadura da face lateral e inferior de viga
transversal da Ponte de Acesso para as medidas eletroqumicas
- 34 -
INTERCORR2010_349
Figura 4 Desenho esquemtico da marcao da grade da armadura de uma das faces laterais de estaca
da Ponte de Acesso para as medidas eletroqumicas
Figura 5 Desenho esquemtico da marcao da grade da armadura da face lateral e inferior de viga
longitudinal do Per Novo para as medidas eletroqumicas
- 35 -
INTERCORR2010_349
Figura 6 Desenho esquemtico da marcao da grade da armadura da face lateral e inferior de viga
transversal do Per Novo para as medidas eletroqumicas
Figura 7 Desenho esquemtico da marcao da grade da armadura de uma das faces laterais de estaca
do Per Novo para as medidas eletroqumicas
- 36 -
INTERCORR2010_349
- 37 -
INTERCORR2010_349
Figura 14 Fratura em regio de uma fissura sem presena de anomalias na face lateral de uma viga
longitudinal da Ponte de Acesso do Per Velho, que mostra o estribo com local sem corroso (regio
acinzentada, trecho na face lateral da viga), despassivado (regio escurecida, trecho na face inferior da
viga ) e local com acmulo de produtos de corroso (regio verde, trecho de quina entre as faces)
- 39 -