CALCULOS 15m A

2m

O E

M
Cal baño

22 kW

0.33333333 CAIDA PRESIÓN OB<= 1MBAR


AP OA =0,33 mbar
0.9338 AP AB= 0,33 mbar
0.4669 AP BC= 0,33 mbar

AP(OC) = 1 mbar= AP(OA) +AP(AB) +AP (BC)

AP(OA) =0,2495
0.7505
0.37525

0.5506

Long real long. Equiv pot simul cuadal sim


TRAMO
TRAZADO m m kW m3/h
OA 15 18 34.5 3.1944
OC AB 12 14.4 15 1.3889
BC 8 9.6 5 0.4630
OD BD 3 3.6 10 0.9259
OE AE 2 2.4 22 2.0370
0.7115
0.35575
12m B 8m
0.4531
3m

D C

COC HOR

10 Kw Rad
5 kW

AP = 1 - 0,2495= 0.7055 AP(AB) = 0.35275


AP(BC)= 0.35275

1.0000
0.5

0.84
0.42

caida de Diametro Diametro Diámetro Caida de


presion interno asumido interno AP presion del
teorica teorico nominal asumido trazado
mbar mm pulg mm mbar mbar
0.3300 25.9066 1 26.64 0.2885
0.35575 17.7807 3/4 20.96 0.1610 0.5069
0.5506 9.8607 1/2 15.76 0.0574
0.5506 10.4519 1/2 15.76 0.0761 0.5255
0.7115 12.2702 1/2 15.76 0.2129 0.5014
0.67 0.7115 0.5506
0.35575
CALCULOS

25m A

3m

O C

M COC HOR
15 kW

0.33333333 CAIDA PRESIÓN OB<= 1MBAR


AP OA =0,33 mbar
0.9338 AP AB= 0,33 mbar
0.4669 AP BC= 0,33 mbar

AP(OC) = 1 mbar= AP(OA) +AP(AB) +AP (BC)

AP(OA) =0,2495
0.7505
0.37525

0.3104

Long real long. Equiv pot simul cuadal sim


TRAMO
TRAZADO m m kW m3/h
OA 25 30 50 4.6296
OB AB 7 8.4 35 3.2407
0
OC AC 3 3.6 15 1.3889
0.4531

7m

CAL BAÑO
35 kW

AP = 1 - 0,2495= 0.7055 AP(AB) = 0.35275


AP(BC)= 0.35275

1.0000
0.5

0.84
0.42

caida de Diametro Diametro Diámetro Caida de


presion interno asumido interno AP presion del
teorica teorico nominal asumido trazado
mbar mm pulg mm mbar mbar
0.5000 30.3982 1 1/4 35.08 0.2507
0.7493 18.7590 3/4 20.96 0.4390 0.6896

0.7493 11.4267 1/2 15.76 0.1591 0.4098


0.7493
CALCULOS 8m A
PA-PO= 0,2495

1,8m

O E

M
COC HOR

15 kW

0.33333333 CAIDA PRESIÓN OB<= 1MBAR


AP OA =0,33 mbar
0.9338 AP AB= 0,33 mbar
0.4669 AP BC= 0,33 mbar

AP(OC) = 1 mbar= AP(OA) +AP(AB) +AP (BC)

AP(OA) =0,2495
0.7505
0.37525

0.4531

Long real long. Equiv pot simul cuadal sim


TRAMO
TRAZADO m m kW m3/h
OA 8 9.6 45 4.1667
OC AB 5 6 34 3.1481
BC 6 7.2 8 0.7407
OD BD 1.5 1.8 26 2.4074
OE AE 1.8 2.16 15 1.3889
5m B 6m
0.4531
PB-PA= 0,2974 1,5m

D C

CAL BAÑO

26 kW Rad
8 kW

AP = 1 - 0,2495= 0.7055 AP(AB) = 0.35275


AP(BC)= 0.35275

1.0000
0.5

0.84
0.42

caida de Diametro Diametro Diámetro Caida de


presion interno asumido interno AP presion del
teorica teorico nominal asumido trazado
mbar mm pulg mm mbar mbar
0.3300 25.1387 1 26.64 0.2495
0.3528 20.2312 3/4 20.96 0.2974 0.6483
0.4531 11.5509 1/2 15.76 0.1013
0.4531 13.5207 1/2 15.76 0.2164 0.7634
0.6700 10.5190 1/2 15.76 0.0954 0.3450
0.67
CALCULOS 8m A

1,8m

O E COC HOR

M
COC HOR

15 kW

0.33333333 CAIDA PRESIÓN OB<= 1MBAR


AP OA =0,33 mbar
0.9338 AP AB= 0,33 mbar
0.4669 AP BC= 0,33 mbar

AP(OC) = 1 mbar= AP(OA) +AP(AB) +AP (BC)

AP(OA) =0,2495
0.7505
0.37525

0.4531

Long real long. Equiv pot simul cuadal sim


TRAMO
TRAZADO m m kW m3/h
OA 8 9.6 45 4.1667
OC AB 5 6 34 3.1481
BC 6 7.2 8 0.7407
OD BD 1.5 1.8 26 2.4074
OE AE 1.8 2.16 15 1.3889
5m B 6m

1,5m

D C

CAL BAÑO

26 kW Rad
8 kW

AP = 1 - 0,2012= 0,7988 mbar

1.0000
0.5

0.84
0.42

caida de Diametro Diametro Diámetro Caida de


presion interno asumido interno AP presion del
teorica teorico nominal asumido trazado
mbar mm pulg mm mbar mbar
0.3300 25.1387 1 26.64 0.2495
0.3750 19.9761 3/4 20.96 0.2974 0.6483
0.4531 11.5509 1/2 15.76 0.1013
0.4531 13.5207 1/2 15.76 0.2164 0.7634
0.7505 10.2743 1/2 15.76 0.0954 0.3450
CALCULOS 12 m A

4m

0 C COC HOR

M
COC HOR

10 kW

CAIDA PRESIÓN OB<= 1MBAR


AP OA =0,5 mbar
AP AB= 0,5 mbar

Long real long. Equiv pot simul cuadal sim


TRAMO
TRAZADO m m kW m3/h
OA 12 14.4 32 2.9630
OB AB 7 8.4 22 2.0370
OC AC 4 4.8 10 0.9259
7m

CAL BAÑO

22 kW

AP = 1 - 0,2012= 0,7988 mbar

1.0000
0.5

0.84
0.42

caida de Diametro Diametro Diámetro Caida de


presion interno asumido interno AP presion del
teorica teorico nominal asumido trazado
mbar mm pulg mm mbar mbar
0.5000 22.0562 1 26.64 0.2012
0.7988 15.5350 3/4 20.96 0.1886 0.3898
0.7988 10.2705 1/2 15.76 0.1014 0.3026
CALCULOS

N de equipos
1

Long real long. Equiv pot simul cuadal sim


TRAZADO TRAMO
m m kW m3/h
OA 7 8.4 38.5 3.5648
OC AB 4 4.8 32 2.9630
BC 3 3.6 25 2.3148
OD BD 2 2.4 7 0.6481
OE AE 1 1.2 10 0.9259

Long real long. Equiv pot simul cuadal sim


TRAMO
TRAMO
m m kW m3/h
OA 7 8.4 38.5 3.5648
AB 4 4.8 32 2.9630
BC 3 3.6 25 2.3148
BD 2 2.4 7 0.6481
N de equipos 3
mbar

caida de Diametro Diametro Diámetro


presion interno asumido AP
asumido
teorica teorico nominal
mbar mm pulg mm mbar
0.3333 23.0050 1" 26.64 0.1644 0.8356
0.4200 18.2076 3/4" 20.96 0.41782091
0.6300 14.3653 1/2" 15.76
0.63 8.1664 1/2" 15.76
#DIV/0!
0.84
0.42

caida de Diametro Diametro Diámetro


presion interno asumido AP
asumido
teorica teorico nominal
mbar mm pulg mm mbar
0.3333 23.0050 1" 26.64 0.1644
0.4200 18.2076 3/4" 20.96
0.6300 14.3653 1/2" 15.76
0.63 8.1664 1/2" 15.76