Você está na página 1de 1

RELATÓRIO Nº: 002-2022

Report nº: 002-2022


RELATÓRIO DE ENSAIO NÃO DESTRUTIVO
FOLHA: 01/01
PARTÍCULAS MAGNÉTICAS Sheet: 01/01
MPI Report DATA: 04/07/2022
Date: 04/07/2022

CLIENTE: Locsolo Locadora de Equipamentos OBRA / CONTRATO: RS-035-22-00 PLATAFORMA: N/A


Client: Locsolo Locadora de Equipamentos Works / Contract: RS-035-22-00 Plataform: N/A
LOCAL DO ENSAIO: Locsolo Serra DESCRIÇÃO/EQUIPAMENTO: N/A
Test Site: Locsolo Serra Description/Equipment: N/A
NORMA DE REFERÊNCIA: N-1598 REVISÃO: G PROCEDIMENTO Nº: PR-TEC-PM-01 REVISÃO.: 08 AS: N/A
Reference Standard: N-1598 Rev.: G Procedure nº: PR-TEC-PM-01 Rev.: 08 S. Authorization: N/A
NOTA/ SEP/OM: N/A DESENHO/ISOMÉTRICO DE REFERÊNCIA/REV.: N/A TAG/IDENTIFICAÇÃO: NP-012
Note/SEP/OM: N/A Drawing/Isometric Reference/ Rev.: N/A Tag/Identification: NP-012
PROCESSO DE SOLDAGEM: N/A METAL BASE: N/A METAL ADIÇÃO: N/A
Welding Process: N/A Base Metal: N/A Metal Addition: N/A

EQUIPAMENTO DE ILUMINAÇÃO: N/A NÍVEL DE ILUMINAÇÃO: >1000 ESPESSURA: 21mm


Lighting/Equipment: N/A Lighting Level: >1000 Thickness: 21mm
MARCA: Metal-check CONDIÇÃO SUPERFICIAL: Escovada TEMPO DE ENSAIO: >30 min
Mark: Metal-check Surface Condition: brushed Time Test: >30 min
TÉCNICA DE MAGNETIZAÇÃO: Yoke APARELHO/FABRICANTE/MODELO: CORRENTE: ( ) CC ( X ) CA
Magnetization Technique: Yoke Yoke / Metal-Check / HMM-06 Corrent: ( ) DC ( X ) AC
VIA: ( )SECA ( X )COLORIDA PART./FABRICANTE.: Metal-Check TINTA DE CONTRASTE/FABRICANTE: 104
Method: ( )Dry ( X ) Visible Magnetic Particles: Metal-Check Contrast paint: 104
( X )ÚMIDA ( )FLUORESCENTE CONCENTRAÇÃO DA SUSPENSÃO: W 222/0
( X )Wet ( )Fluorescente Suspension Concentration: W 222/0
PREPARAÇÃO/Preparation: N/A DECANTAÇÃO/Decantation: N/A

REGISTRO DE RESULTADOS LOCALIZAÇÃO DO DEFEITO: N/A


SOLDA / PEÇA Fault Location: N/A
Weld/ Part Extensão % Ensaio Número Tipo Cota Compr. Laudo
Extension of Test Nr Type Height Length Status
Ponta do Eixo 100% - - - - A

Croqui

OBSERVAÇÕES: Ensaio realizado apenas


na ponta do eixo do motor.

Comment: Test performed only on the


motor shaft end.

LEGENDA Legend:
A - Aprovado / Aproved: TL - Trinca longitudinal / Longitudinal Crack FP - Falta de penetração/Insuficient Penetration

R - Reprovado / Rejected TT - Trinca transversal / Transverse Crack MO - Mordedura / Undercut

REC - Recomendação de exame complementar TR - Trinca ramificada / branched crack SP - Sobreposição / Overlap

Recommended Examination FF- Falta de Fusão / Lack Fusion PO - Poro ou porosidade / Porosity

INSPETOR: Raimundo Pires de Araújo COORDENADOR DA QUALIDADE: CLIENTE:


Inspector: Raimundo Pires de Araújo Control Coordinator: Client:
Assinatura: Assinatura: Assinatura:
Signature: Signature: Signature:
Identificação: SNQC-END.: 1005 Identificação: Identificação:
Identification: PM-N2-S-Y / LP-N2-G Identification: Identification:
US-N2-S2.1 / US-N2-S4
Data: 04/07/2022 Data: Data:
Date: 04/07/2022 Date: Date:

FM-TEC-PM-01 REV.08 Data: 17/03/2018

Você também pode gostar