SISTEMA: TRIFÁSICO
CORRIGIR TEMPERATURA PARA: 30 °C
FATOR DE TEMPERATURA 1 Iz TENSÃO PARA
Ib<=In? In<=Iz? OBTENÇÃO DA
CORRIGIDA CORRENTE
FA
TIPO DE
POTÊNCIA FATOR TENSÃO CORRENTE DISJUNTOR CONDUTOR (mm²) BALANCEAMENTO TOTAL DEMANDA
QTDE. FA CARGA CIRCUITO FINALIDADE GERAL MONO TRI MONO TRI
(VA) DEMANDA (V) (A) A kA NP F N PE R S T R S T R S T
1 1 K QFAC-1 QUADRO DE FORÇA DE AR CONDICIONADO 1 75000 0.8 220 - 3φ 196.82 200 5 3 95 16 16 1 1 1 1 232 207 381.1 QFAC-1 X X 196.82 196.82 - 157.46 157.46 -
1 1 M QLT QUADRO DE LUZ E TOMADAS 5467.2 1 220 - 3φ 14.35 25 5 3 4 4 4 1 1 1 1 32 28 381.1 QLT X X 14.35 14.35 - 14.35 14.35 -
1 1 N RES RESERVA - - 220 - 3φ - 25 5 3 - - - 1 #N/A #N/A #N/A #N/A #N/A 381.1 RES X X - - - - - -
1 1 N RES RESERVA - - 220 - 3φ - 25 5 3 - - - 1 #N/A #N/A #N/A #N/A #N/A 381.1 RES X X - - - - - -
1 1 L NB NO-BREAK 8000 1 220 - 2φ 36.36 40 5 2 10 - 10 1 1 1 1 57 50 220.0 NB X X - 36.36 36.36 - 36.36 36.36
1 1 N BP BY-PASS 8000 - 220 - 2φ 36.36 40 5 2 10 - 10 1 1 1 1 57 50 220.0 BP X X - 36.36 36.36 - #VALUE! #VALUE!
1 1 M ESTAB. ESTABILIZADOR 4000 1 220 - 2φ 18.18 20 5 2 4 - 4 1 1 1 1 32 28 220.0 ESTAB. X X 18.18 18.18 - 18.18 18.18 -
1 1 N RES RESERVA - - 220 - 2φ - 40 5 2 - - - 1 #N/A #N/A #N/A #N/A #N/A 220.0 RES X X - - - - - -
- N RES RESERVA - - 220 - 2φ - 40 5 2 - - - 1 #N/A #N/A #N/A #N/A #N/A 220.0 RES X X - - - - - -
- N RES RESERVA - - 220 - 2φ - 20 5 2 - - - 1 #N/A #N/A #N/A #N/A #N/A 220.0 RES X X
FA
TIPO DE
POTÊNCIA FATOR TENSÃO CORRENTE DISJUNTOR CONDUTOR (mm²) BALANCEAMENTO TOTAL DEMANDA
QTDE. FA CARGA CIRCUITO FINALIDADE GERAL MONO TRI MONO TRI
(VA) DEMANDA (V) (A) A kA NP F N PE R S T R S T R S T
3 0.7 M PE-1 PDGM 250 0.5 220 - 2φ 1.14 10 5 2 2.5 - 2.5 1 1 1 1 16.8 14.7 220.0 PE-1 X X 1.14 1.14 - 0.57 0.57 -
3 0.7 M PE-2 PE-AA-04 1142 1 220 - 2φ 5.19 10 5 2 2.5 - 2.5 1 1 1 1 16.8 14.7 220.0 PE-2 X X 5.19 5.19 - 5.19 5.19 -
3 0.7 M PE-3 PE-AA-05 1142 1 220 - 2φ 5.19 10 5 2 2.5 - 2.5 1 1 1 1 16.8 14.7 220.0 PE-3 X X 5.19 5.19 - 5.19 5.19 -
3 0.7 M PE-4 PE-AA-06 1142 1 220 - 2φ 5.19 10 5 2 2.5 - 2.5 1 1 1 1 16.8 14.7 220.0 PE-4 X X 5.19 5.19 - 5.19 5.19 -
3 0.7 M PE-5 PE-TS-03 1142 1 220 - 2φ 5.19 10 5 2 2.5 - 2.5 1 1 1 1 16.8 14.7 220.0 PE-5 X X 5.19 5.19 - 5.19 5.19 -
3 0.7 N RES RESERVA - - 220 - 2φ - 10 5 2 - - - 1 #N/A #N/A #N/A #N/A #N/A 220.0 RES X X - - - - - -
3 0.7 N RES RESERVA - - 220 - 2φ - 10 5 2 - - - 1 #N/A #N/A #N/A #N/A #N/A 220.0 RES X X - - - - - -
3 0.7 N RES RESERVA - - 220 - 2φ - 10 5 2 - - - 1 #N/A #N/A #N/A #N/A #N/A 220.0 RES X X - - - - - -
FATORES DE DEMANDA
FINALIDADE DO CIRCUITO
L NO-BREAK
DADOS ELÉTRICOS
TENSÃO DE ALIMENTAÇÃO: 220/127V
SISTEMA: 3F+N+PE
CORRENTE MÍNIMA DOS BARRAMENTOS: 100A
FREQUÊNCIA: 60Hz
Icc MÍNIMA DOS BARRAMENTOS: 15kA
DISJUNTORES DE ENTRADA: 50A
Icu DISJUNTORES DE ENTRADA: 15kA
220/127 V 381.0511777
TRIFÁSICO
30 °C
1 In 1,25xIn
Ib<=In? In<=Iz?
15000 VA 39.36 A 49.21 A
,
FATOR TENSÃO CORRENTE DISJUNTOR CONDUTOR (mm²)
GERAL
DEMANDA (V) (A) A kA NP F N PE
1 220 - 2φ 2.73 16 5 2 2.5 - 2.5 1 1
- 220 - 2φ 2.73 16 5 2 2.5 - 2.5 1 1
1 220 - 2φ 5.45 16 5 2 2.5 - 2.5 1 1
- 220 - 2φ 5.45 16 5 2 2.5 - 2.5 1 1
1 220 - 2φ 8.18 16 5 2 2.5 - 2.5 1 1
- 220 - 2φ 8.18 16 5 2 2.5 - 2.5 1 1
1 220 - 2φ 2.18 16 5 2 2.5 - 2.5 1 1
1 220 - 2φ 2.73 16 5 2 2.5 - 2.5 1 1
1 220 - 2φ 3.07 16 5 2 2.5 - 2.5 1 1
1 220 - 2φ 4.77 16 5 2 2.5 - 2.5 1 1
1 220 - 2φ 3.18 16 5 2 2.5 - 2.5 1 1
1 220 - 2φ 3.18 16 5 2 2.5 - 2.5 1 1
1 220 - 2φ 2.20 16 5 2 2.5 - 2.5 1 1
1 220 - 2φ 1.09 16 5 2 2.5 - 2.5 1 1
1 220 - 2φ 1.36 16 5 2 2.5 - 2.5 1 1
1 220 - 2φ 2.46 16 5 2 2.5 - 2.5 1 1
1 220 - 2φ 1.12 16 5 2 2.5 - 2.5 1 1
1 220 - 2φ 2.27 16 5 2 2.5 - 2.5 1 1
- 220 - 2φ - 16 5 2 - - - 1 1
- 220 - 2φ - 16 5 2 - - - 1 1
- 220 - 2φ - 16 5 2 - - - 1 1
- 220 - 2φ - 16 5 2 - - - 1 1
POTÊNCIAS DEMANDADAS
FD (VA)
1.0 NO-BREAK 10118 10118.00
POTÊNCIA DEMANDADA TOTAL: 0 10118.00
RESERVA: 0 4882.00
220/127V DEMANDA + RESERVA: 0 15000.00
3F+N+PE TENSÃO: 0 220/127V
100A CORRENTE (A): 0 39.36
60Hz
15kA
50A
15kA
Iz
In<=Iz? TENSÃO PARA OBTENÇÃO DA CORRENTE
CORRIGIDA
BALANCEAMENTO
MONO TRI MONO TRI
R S
1 0 16.8 14.7 220.0 E1 X X
1 0 16.8 14.7 220.0 E2 X X
1 0 16.8 14.7 220.0 E3 X X
1 0 16.8 14.7 220.0 E4 X X
1 0 16.8 14.7 220.0 E5 X X
1 0 16.8 14.7 220.0 E6 X X
1 0 16.8 14.7 220.0 E7 X X
1 0 16.8 14.7 220.0 E8 X X
1 0 16.8 14.7 220.0 E9 X X
1 0 16.8 14.7 220.0 E10 X X
1 0 16.8 14.7 220.0 E11 X X
1 0 16.8 14.7 220.0 E12 X X
1 0 16.8 14.7 220.0 E13 X X
1 0 16.8 14.7 220.0 E14 X X
1 0 16.8 14.7 220.0 E15 X X
1 0 16.8 14.7 220.0 E16 X X
1 0 16.8 14.7 220.0 E17 X X
1 0 16.8 14.7 220.0 E18 X X
1 0 16.8 14.7 220.0 RES X X
1 0 16.8 14.7 220.0 RES X X
1 0 16.8 14.7 220.0 RES X X
1 0 16.8 14.7 220.0 RES X X
NCEAMENTO TOTAL DEMANDA
T R S T R S T
2.73 2.73 - 2.73 2.73 -
2.73 2.73 - #VALUE! #VALUE! -
5.45 5.45 - 5.45 5.45 -
5.45 5.45 - #VALUE! #VALUE! -
8.18 8.18 - 8.18 8.18 -
8.18 8.18 - #VALUE! #VALUE! -
2.18 2.18 - 2.18 2.18 -
2.73 2.73 - 2.73 2.73 -
3.07 3.07 - 3.07 3.07 -
4.77 4.77 - 4.77 4.77 -
3.18 3.18 - 3.18 3.18 -
3.18 3.18 - 3.18 3.18 -
2.20 2.20 - 2.20 2.20 -
1.09 1.09 - 1.09 1.09 -
1.36 1.36 - 1.36 1.36 -
2.46 2.46 - 2.46 2.46 -
1.12 1.12 - 1.12 1.12 -
2.27 2.27 - 2.27 2.27 -
- - - - - -
- - - - - -
- - - - - -
- - - - - -
FA
TIPO DE
POTÊNCIA FATOR TENSÃO CORRENTE DISJUNTOR CONDUTOR (mm²) BALANCEAMENTO TOTAL DEMANDA
QTDE. FA CARGA CIRCUITO FINALIDADE GERAL MONO TRI MONO TRI
(VA) DEMANDA (V) (A) ID A kA NP F N PE R S T R S T R S T
3 0.7 A RES EM 50 0.9 220 - 2φ 0.23 Q1 20 5 2 6 - 6 1 1 1 1 28.7 25.2 220.0 RES X X 0.23 0.23 - 0.20 0.20 -
3 0.7 D RES GERENTE 400 0.5 220 - 2φ 1.82 Q2 32 5 2 10 - 10 1 1 1 1 39.9 35 220.0 RES X X 1.82 1.82 - 0.91 0.91 -
3 0.7 D RES FECHADURA 150 0.5 220 0.68 Q3 32 5 1 10 10 10 1 1 1 1 39.9 35 220.0 RES X X 0.68 - 0.68 0.34 - 0.34
3 0.7 D RES ATM 560 0.5 127 4.41 Q4 20 5 1 4 4 4 1 1 1 0 22.4 19.6 127.0 RES X X 4.41 - 4.41 2.20 - 2.20
3 0.7 D RES MICR 900 0.5 127 7.09 Q5 20 5 1 6 6 6 1 1 1 1 28.7 25.2 127.0 RES X X - 7.09 7.09 - 3.54 3.54
3 0.7 N RES RESERVA - - 127 - Q6 16 5 1 - - - 1 #N/A #N/A #N/A #N/A #N/A 127.0 RES X X - - - - - -
3 0.7 D RES TUG COPA 100 0.5 127 0.79 Q7 16 5 1 - - - 1 #N/A #N/A #N/A #N/A #N/A 127.0 RES X X 0.79 0.79 - 0.39 0.39 -
3 0.7 N RES RESERVA - - 127 - Q8 16 5 1 - - - 1 #N/A #N/A #N/A #N/A #N/A 127.0 RES X X - - - - - -
3 0.7 D RES WIFI 200 0.5 127 1.57 Q9 16 5 1 - - - 1 #N/A #N/A #N/A #N/A #N/A 127.0 RES X X 1.57 - 1.57 0.79 - 0.79
3 0.7 M RES AMT 560 0.5 127 4.41 Q10 16 5 1 - - - 1 #N/A #N/A #N/A #N/A #N/A 127.0 RES X X 4.41 - 4.41 2.20 - 2.20
3 0.7 N RES RESERVA - - 127 - Q11 16 5 1 - - - 1 #N/A #N/A #N/A #N/A #N/A 127.0 RES X X - - - - - -
3 0.7 K RES 3 2900 0.8 220 - 2φ 13.18 Q12 16 5 2 - - - 1 #N/A #N/A #N/A #N/A #N/A 220.0 RES X X - 13.18 13.18 - 10.55 10.55
2 0.8 N RES RESERVA - - 127 - Q13 16 5 2 - - - 1 #N/A #N/A #N/A #N/A #N/A 127.0 RES X X - - - - - -
3 0.7 K RES 1 1990 0.8 220 - 2φ 9.05 Q14 16 5 2 - - - 1 #N/A #N/A #N/A #N/A #N/A 220.0 RES X X - 9.05 9.05 - 7.24 7.24
2 0.8 K RES 2 2900 0.8 220 - 2φ 13.18 Q15 16 5 2 - - - 1 #N/A #N/A #N/A #N/A #N/A 220.0 RES X X 13.18 13.18 - 10.55 10.55 -
3 0.7 A RES ILU 870 0.9 220 - 2φ 3.95 Q5 20 5 2 6 - 6 1 1 1 1 28.7 25.2 220.0 RES X X - 3.95 3.95 - 3.56 3.56
3 0.7 A RES VIG 72 0.9 220 - 2φ 0.33 Q6 16 5 2 - - - 1 #N/A #N/A #N/A #N/A #N/A 220.0 RES X X - 0.33 0.33 - 0.29 0.29
3 0.7 N RES RESERVA - - 127 - Q7 16 5 1 - - - 1 #N/A #N/A #N/A #N/A #N/A 127.0 RES X X - - - - - -
3 0.7 C RES ESPERA 300 0.2 127 2.36 Q8 16 5 1 - - - 1 #N/A #N/A #N/A #N/A #N/A 127.0 RES X X 2.36 2.36 - 0.47 0.47 -
3 0.7 E RES IMPRES 1056 0.3 127 8.31 Q9 16 5 1 - - - 1 #N/A #N/A #N/A #N/A #N/A 127.0 RES X X 8.31 - 8.31 2.49 - 2.49
3 0.7 H RES RACK 400 1 127 3.15 Q10 16 5 1 - - - 1 #N/A #N/A #N/A #N/A #N/A 127.0 RES X X 3.15 - 3.15 3.15 - 3.15
3 0.7 D RES FRIGOBAR 400 0.5 127 3.15 Q11 16 5 1 - - - 1 #N/A #N/A #N/A #N/A #N/A 127.0 RES X X - 3.15 3.15 - 1.57 1.57
3 0.7 D RES EXP 80 0.5 127 0.63 Q12 16 5 1 - - - 1 #N/A #N/A #N/A #N/A #N/A 127.0 RES X X - 0.63 0.63 - 0.31 0.31
2 0.8 N RES RESERVA - - 127 - Q13 16 5 2 - - - 1 #N/A #N/A #N/A #N/A #N/A 127.0 RES X X - - - - - -
3 0.7 K RES 1 2900 0.8 220 - 2φ 13.18 Q14 16 5 2 - - - 1 #N/A #N/A #N/A #N/A #N/A 220.0 RES X X - 13.18 13.18 - 10.55 10.55
2 0.8 M RES PORTA 100 0.5 127 0.79 Q15 16 5 2 - - - 1 #N/A #N/A #N/A #N/A #N/A 127.0 RES X X 0.79 0.79 - 0.39 0.39 -
3 0.7 D RES RACK 400 0.5 127 3.15 Q6 16 5 1 - - - 1 #N/A #N/A #N/A #N/A #N/A 127.0 RES X X - 3.15 3.15 - 1.57 1.57
3 0.7 K RES AA 1626 0.8 220 - 2φ 7.39 Q7 16 5 2 - - - 1 #N/A #N/A #N/A #N/A #N/A 220.0 RES X X 7.39 7.39 - 5.91 5.91 -
3 0.7 K RES GAB 215 0.8 220 - 2φ 0.98 Q8 16 5 2 - - - 1 #N/A #N/A #N/A #N/A #N/A 220.0 RES X X 0.98 0.98 - 0.78 0.78 -
3 0.7 N RES RESERVA - - 220 - 2φ - Q9 16 5 2 - - - 1 #N/A #N/A #N/A #N/A #N/A 220.0 RES X X - - - - - -
3 0.7 N RES RESERVA - - 220 - 2φ - Q16 16 5 2 - - - 1 #N/A #N/A #N/A #N/A #N/A 220.0 RES X X - - - - - -
FA
TIPO DE
POTÊNCIA FATOR TENSÃO CORRENTE DISJUNTOR CONDUTOR (mm²) BALANCEAMENTO TOTAL DEMANDA
QTDE. FA CARGA CIRCUITO FINALIDADE GERAL MONO TRI MONO TRI
(VA) DEMANDA (V) (A) A kA NP F N PE R S T R S T R S T
3 0.7 A i01 ILUMINAÇÃO AGÊNCIA 1330 0.9 220 - 2φ 6.05 16 5 2 2.5 - 2.5 1 1 1 0 16.8 14.7 220.0 i01 X X 6.05 6.05 - 5.44 5.44 -
ILUMINAÇÃO RETAGUARDA / SANITÁRIOS / COPA / TESOURARIA /
3 0.7 A i02
SALA TÉCNICA
1197 0.9 220 - 2φ 5.44 16 5 2 2.5 - 2.5 1 1 1 0 16.8 14.7 220.0
3 0.7 B HL1 TESTEIRA 500 0.2 220 - 2φ 2.27 16 5 2 2.5 - 2.5 1 1 1 0 16.8 14.7 220.0
3 0.7 A HL2 ILUMINAÇÃO AUTOATENDIMENTO 368 0.9 220 - 2φ 1.67 16 5 2 2.5 - 2.5 1 1 1 0 16.8 14.7 220.0
3 0.7 B HL3 ILUMINAÇÃO EXTERNA 828 0.2 220 - 2φ 3.76 16 5 2 2.5 - 2.5 1 1 1 0 16.8 14.7 220.0
3 0.7 A EM ILUMINAÇÃO DE EMERGÊNCIA 205 0.9 220 - 2φ 0.93 16 5 2 2.5 - 2.5 1 1 1 0 16.8 14.7 220.0
3 0.7 M COM. COMANDO 100 0.5 220 - 2φ 0.45 16 5 2 2.5 - 2.5 1 1 1 0 16.8 14.7 220.0
3 0.7 N RES RESERVA - - 220 - 2φ - 16 5 2 - - - 1 #N/A #N/A #N/A #N/A #N/A 220.0
3 0.7 N RES RESERVA - - 220 - 2φ - 16 5 2 - - - 1 #N/A #N/A #N/A #N/A #N/A 220.0
3 0.7 N RES RESERVA - - 220 - 2φ - 16 5 2 - - - 1 #N/A #N/A #N/A #N/A #N/A 220.0
3 0.7 N RES RESERVA - - 220 - 2φ - 16 5 2 - - - 1 #N/A #N/A #N/A #N/A #N/A 220.0
FA
TIPO DE
CARGA CIRCUITO POTÊNCIA FATOR TENSÃO
QTDE. FINALIDADE
(VA) DEMANDA (V)
2 A L1 ILUM 1900000 0.9 220 - 2φ
7 B C1 TUG 500 0.2 127
2 A 139000 0.9
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
CORRENTE DISJUNTOR CONDUTOR (mm²) CONDUTOR (mm²)
CIRCUITO
(A) A kA NP F N PE F N PE
8636.36 16 2 2.5 - 2.5 2.5 - 2.5
3.94 32 1 2.5 2.5 2.5 C1 2.5 - 2.5
- - C3 25 - 25
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
DISJUNTOR CORRENTE TENSÃO FATOR CARGA
FINALIDADE
A kA NP (A) (V) DEMANDA (VA)
10 1 23.62 127 0.9 3000
20 1 3.94 127 0.2 500
50 1 47.24 127 0.9 6000
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
Iz
In<=Iz?
CORRIGIDA
TENSÃO PARA
Ib<=In? OBTENÇÃO DA
FA CORRENTE
TIPO DE
GERAL MONO TRI MONO TRI
QTDE. FA CARGA
1 1 E 0 0 1 0 24 21 127.0
2 0.8 A 1 1 1 1 19.2 16.8 127.0
2 0.8 A 1 1 1 1 80.8 71.2 127.0
#N/A - 0 0 0 0 0 0.0
#N/A - 0 0 0 0 0 0.0
#N/A - 0 0 0 0 0 0.0
#N/A - 0 0 0 0 0 0.0
#N/A - 0 0 0 0 0 0.0
#N/A - 0 0 0 0 0 0.0
#N/A - 0 0 0 0 0 0.0
#N/A - 0 0 0 0 0 0.0
#N/A - 0 0 0 0 0 0.0
#N/A - 0 0 0 0 0 0.0
#N/A - 0 0 0 0 0 0.0
#N/A - 0 0 0 0 0 0.0
#N/A - 0 0 0 0 0 0.0
#N/A - 0 0 0 0 0 0.0
#N/A - 0 0 0 0 0 0.0
#N/A - 0 0 0 0 0 0.0
#N/A - 0 0 0 0 0 0.0
#N/A - 0 0 0 0 0 0.0
DEMANDAS POTÊNCIAS DEMANDADAS (VA)
CAPACIDADES DE TENSÕES
RUPTURA
TENSÃO kA 220/127
380 4.5 380/220
380 12 230/115
380 240/120
380 254/127
380 220/110
220 5
220 25
220 20
220
220
FATORES DE
FATORES DE TEMPERATURA CÓD.
AGRUPAMENTO
TEMPERATURA FATOR CIRCUITOS FATOR A
20 1.12 B
25 1.06 1 1 C
30 1 2 0.8 D
35 0.94 3 0.7 E
40 0.87 4 0.65 F
5 0.6 G
6 0.57 H
7 0.5 I
8 0.52 J
9 0.5 K
10 0.5 L
M
N
O
SISTEMA
BIFÁSICO
TRIFÁSICO
TIPO DE CARGA FD
ILUMINAÇÃO INTERNA 0.9
ILUMINAÇÃO EXTERNA 0.2
TUG'S 0.2
TUE'S 0.5
IMPRESSORAS 0.3
SINALIZAÇÃO EXTERNA 0.2
TERMINAIS DE CAIXA 1.00
RACK DA TECNOLOGIA 1.00
CASH 1.00
COMPUTADORES 1.00
AR CONDICIONADO 0.80
NO BREAK 1.00
OUTROS EQUIPAMENTOS 0.5
RESERVA -
BACKUP RACK / BY-PASS 0.00