Escolar Documentos
Profissional Documentos
Cultura Documentos
Vista Explodida - Onp 20 - 200 - 140 Psi B
Vista Explodida - Onp 20 - 200 - 140 Psi B
VE VE65
Modelo Model 8975 7010 52 8975 7010 54
Deslocamento Displacement
20 20
(PCM) (CFM)
Pressão Máx. Max. Pressure
140 140
(psi) (psi)
RPM 875 875
HP - 5
Pólos Poles - 2
Frequência (Hz) Frequency (Hz) - 60
Proteção Protection - 21
Tensão (V) Tension (V) - 220/380
Correia Belt 4PK-1178 4PK-1178
Volante Flywheel 260 260
Polia Pulley 65 65
Eixo Polia* Pulley shaft* 19,05 P 19,05 P
Óleo (ml) Oil (ml) 630 630
Massa (kg) Mass (kg) 140 160
Volume Tank
Reservatório Volume 200 200
(l) (l)
A (mm) 1445 1445
B (mm) 460 460
C (mm) 900 900
D (mm) 895 895
E (mm) 330 330
F (mm) - -
G (mm) - -
* P - Paralelo / Parallel; C - Cônico / Conical
COMPRESSOR FIXO 20PCM - 200 LITROS - 140 PSI VE65
20 CFM FIXED COMPRESSOR - 200 LITERS - 140 PSI REV 00
PLANO DE MANUTENÇÃO
PERÍODO HORAS DE FUNCIONAMENTO OPERAÇÃO
- Verificar o nível de óleo antes da partida. Após parada, drenar o
DIARIAMENTE -
condensado do reservatório.
TRIMESTRALMENTE 600 Estas ocorrências são possíveis devido a forma construtiva de todo
compressor a pistão que apresenta uma vibração natural. Desra forma, pode
ocorrer o comprometimento no torque de aperto original de fábrica em
parafusos e conexões.
MAINTENANCE PLAN
PERIOD OPERATING HOURS OPERATION
- Check the oil level before starting up. After stopping, drain the condensate
DAILY -
from the tank.
- Clean the filtering element with a blast of dry compressed air, and if there
WEEKLY - is oil on it, blast on the opposite direction of the air intake flow.
ATTENTION: never use pressure higher than 40 psi.
FIRST MONTH 50 - Fist oil change.
BIMONTHLY 200 - Filter and oil change.
- Check for possible leaks at joints, valves, connections and tubing.
These occurences are possibel due to the way every piston compressor that
QUARTERLY 600
presents natural vibration is built. The original factory tightening torque on
bolts and connections can thus be compromised.
- Inspect the valves (located between the top of the cylinder and the cylinder
9 MONTHS 1000
cap), and clean if necessary.
ANNUALLY - - Calibrate the safety valve with the relevant entity.
COMPRESSOR FIXO 20PCM - 200 LITROS - 140 PSI VE65
20 CFM FIXED COMPRESSOR - 200 LITERS - 140 PSI REV 00
REV DATA QTD (DESCRIÇÃO) DESCRIPTION CÓDIGO (CODE) -QTD (DESCRIÇÃO NOVA) NEW DESCRIPTION CÓDIGO - CODE
REV 00 - - - - - - - - -