Escolar Documentos
Profissional Documentos
Cultura Documentos
Ric BT PDF
Ric BT PDF
Verso 1.4
SUMRIO
1
2
3
3.1
3.2
3.3
3.4
3.5
3.6
3.7
3.8
3.9
3.10
3.11
3.12
3.13
3.14
3.15
3.16
3.17
3.18
3.19
3.20
3.21
3.22
3.23
3.24
3.25
3.26
3.27
3.28
3.29
3.30
3.31
3.32
3.33
3.34
3.35
3.36
3.37
3.38
3.39
3.40
3.41
OBJETIVO ............................................................................................................................................... 5
REFERNCIAS NORMATIVAS .............................................................................................................. 5
TERMINOLOGIAS E DEFINIES ........................................................................................................ 6
Agrupamento no pertencente edificao de mltiplas unidades ........................................................ 6
Barra de Proteo .................................................................................................................................... 6
Caixa de distribuio (CD) ....................................................................................................................... 6
Caixa de entrada e distribuio (CED)..................................................................................................... 6
Caixa de passagem.................................................................................................................................. 6
Caixa de proteo (CP) ............................................................................................................................ 6
Caixa de medio..................................................................................................................................... 6
Carga instalada ........................................................................................................................................ 6
Cavidade de inspeo .............................................................................................................................. 7
Centro de medio ................................................................................................................................... 7
Circuito alimentador ................................................................................................................................. 7
Circuito de distribuio ............................................................................................................................. 7
Circuito de interligao ............................................................................................................................. 7
Condomnio horizontal ............................................................................................................................. 7
Condutor de aterramento ......................................................................................................................... 7
Condutor de proteo............................................................................................................................... 7
Consumidor .............................................................................................................................................. 7
Demanda .................................................................................................................................................. 7
Disjuntor ................................................................................................................................................... 7
Dispositivo de proteo contra surtos (DPS) ........................................................................................... 7
Dispositivo de proteo a corrente diferencial-residual (DR) .................................................................. 7
Distribuidora ............................................................................................................................................. 7
Edificao de mltiplas unidades consumidoras ..................................................................................... 7
Energia eltrica ativa ................................................................................................................................ 8
Energia eltrica reativa............................................................................................................................. 8
Entrada de energia ................................................................................................................................... 8
Entrada de servio ................................................................................................................................... 8
Limite de propriedade............................................................................................................................... 8
Livre e fcil acesso ................................................................................................................................... 8
Medidor .................................................................................................................................................... 8
Origem da instalao ............................................................................................................................... 8
Pontalete .................................................................................................................................................. 8
Ponto de entrega ...................................................................................................................................... 8
Poste concreto armado com caixa de medio embutida ....................................................................... 8
Poste metlico com caixa de medio acoplada ..................................................................................... 8
Poste particular ........................................................................................................................................ 8
Poste particular compartilhado ................................................................................................................. 8
Quadro ou painel de medidores ............................................................................................................... 8
Ramal de entrada ..................................................................................................................................... 9
Ramal de ligao...................................................................................................................................... 9
Unidade consumidora .............................................................................................................................. 9
4
4.1
4.2
4.3
4.4
4.5
4.6
4.7
5
5.1
5.2
5.3
5.4
5.5
6
6.1
6.2
7
7.1
7.2
PROJETO .............................................................................................................................................. 14
Apresentao ......................................................................................................................................... 15
Clculo da demanda .............................................................................................................................. 16
8
8.1
8.2
8.3
9
9.1
9.2
9.3
9.4
9.5
MEDIO .............................................................................................................................................. 22
Tipos ....................................................................................................................................................... 22
Caixas e/ou painis para medio ......................................................................................................... 23
Caixa de proteo (CP) .......................................................................................................................... 24
Caixa de entrada e distribuio (CED)................................................................................................... 24
Aspectos construtivos para montagem do centro de medio .............................................................. 25
10
10.1
10.2
10.3
10.4
10.5
10.6
10.7
10.8
11
VIGNCIA .............................................................................................................................................. 29
ANEXOS
ANEXO A ELETRODOS DE ATERRAMENTO CONVENCIONAIS ........................................................................................................ 31
ANEXO B ESPECIFICAO DA CAIXA DE MEDIO ...................................................................................................................... 32
ANEXO C POTNCIA MDIA DE APARELHOS ............................................................................................................................... 64
ANEXO D FATORES DE DEMANDA PARA ILUMINAO E TOMADAS................................................................................................ 65
ANEXO E - FATORES DE DEMANDA PARA CONDICIONADOR DE AR RESIDENCIAL ............................................................................. 66
ANEXO F - FATORES DE DEMANDA PARA CONDICIONADOR DE AR COMERCIAL ............................................................................... 66
ANEXO G - FATORES DE DEMANDA PARA MOTORES ..................................................................................................................... 66
ANEXO H - FATORES DE DEMANDA PARA APARELHOS ESPECIAIS .................................................................................................. 67
ANEXO I - FATORES DE DEMANDA APARELHOS DE AQUECIMENTO ................................................................................................. 67
ANEXO J DIMENSIONAMENTO DA ENTRADA DE SERVIO ............................................................................................................. 68
ANEXO K - DIMENSIONAMENTO DE POSTES E PONTALETES ........................................................................................................... 70
ANEXO L - DISPOSITIVOS PARA REDUO DA CORRENTE DE PARTIDA DE MOTORES ...................................................................... 71
ANEXO M CAPACIDADE DE CORRENTE EM BARRAMENTOS ......................................................................................................... 72
ANEXO N - CAPACIDADE DE CORRENTE EM CONDUTOR ................................................................................................................ 72
ANEXO O - ELETRODUTO DE PVC RGIDO TIPO ROSQUEVEL ....................................................................................................... 73
ANEXO P - ELETRODUTO RGIDO DE AO-CARBONO ..................................................................................................................... 73
ANEXO Q - OCUPAO MXIMA DOS ELETRODUTOS DE PVC ........................................................................................................ 74
ANEXO R - OCUPAO MXIMA DOS ELETRODUTOS DE AO ......................................................................................................... 74
ANEXO S - EXEMPLOS DE CLCULOS DA DEMANDA ....................................................................................................................... 75
ANEXO T - DEMANDA DE UNIDADE CONSUMIDORA RESIDENCIAL EM FUNO DA REA ................................................................... 82
ANEXO U FATOR DE DIVERSIDADE EM FUNO DO N DE UNIDADES CONSUMIDORA ................................................................... 83
ANEXO V RESISTNCIA DE CONDUTOR PARA CLASSE DE ENCORDOAMENTO 1 ............................................................................ 84
ANEXO W - RESISTNCIA DE CONDUTOR PARA CLASSE DE ENCORDOAMENTO 2 ............................................................................ 84
ANEXO X - CLCULO DE QUEDA DE TENSO ................................................................................................................................ 85
ANEXO Y- POSTE DE CONCRETO ARMADO ................................................................................................................................... 87
ANEXO Z AGRUPAMENTOS ......................................................................................................................................................... 89
FIGURAS
FIGURA 1 COMPONENTES DA ENTRADA DE SERVIO..................................................................................................... 116
FIGURA 2 ALTURAS MNIMAS DO RAMAL DE LIGAO AO SOLO .................................................................................... 117
FIGURA 3 DISPOSIO DA ENTRADA DE SERVIO .......................................................................................................... 118
FIGURA 4 DISPOSIO DO RAMAL DE ENTRADA SUBTERRNEO .................................................................................. 119
FIGURA 5 (A) MEDIO INDEPENDENTE DA REA PRIVADA (VISTA SUPERIOR) .......................................................... 120
FIGURA 5 (B) MEDIO INDEPENDENTE DA REA PRIVADA ........................................................................................... 121
FIGURA 6 ENTRADA DE ENERGIA COM MEDIO INSTALADA EM POSTE PARTICULAR .............................................. 122
FIGURA 7 (A) ENTRADA DE ENERGIA COM MEDIO MONOFSICA INSTALADA EM POSTE DE AO ......................... 123
FIGURA 7 (B) ENTRADA DE ENERGIA COM MEDIO POLIFSICA INSTALADA EM POSTE DE AO............................ 124
FIGURA 8 (A) ENTRADA DE ENERGIA COM MEDIO INSTALADA EM MURO OU MURETA LATERAL COM POSTE
COMPARTILHADO ..................................................................................................................................................... 125
FIGURA 8 (B) ENTRADA DE ENERGIA COM MEDIO INSTALADA EM MURO OU MURETA FRONTAL COM POSTE
COMPARTILHADO ..................................................................................................................................................... 126
FIGURA 8 (C) ENTRADA DE ENERGIA COM MEDIO INSTALADA COM POSTE COMPARTILHADO ............................. 127
FIGURA 8 (D) ENTRADA DE ENERGIA COM MEDIO INSTALADA COM POSTE COMPARTILHADO ............................. 128
FIGURA 9 (A) ENTRADA DE ENERGIA COM MEDIO INSTALADA EM MURO OU MURETA ........................................... 129
FIGURA 9 (B) ENTRADA DE ENERGIA COM MEDIO INSTALADA EM MURO OU MURETA FRONTAL ......................... 130
FIGURA 9 (C) ENTRADA DE ENERGIA COM MEDIO INSTALADA EM MURO OU MURETA FRONTAL ......................... 131
FIGURA 9 (D) ENTRADA DE ENERGIA COM MEDIO FRONTAL INSTALADA EM GRADE ............................................. 132
FIGURA 10 ENTRADA DE ENERGIA COM MEDIO INSTALADA EM PAREDE FRONTAL ............................................... 133
FIGURA 11 ENTRADA DE ENERGIA COM MEDIO INSTALADA EM PAREDE LATERAL, CASA NO ALINHAMENTO .... 134
FIGURA 12 ENTRADA DE ENERGIA COM MEDIO INSTALADA NA PAREDE COM PONTALETE, PRDIO NO
ALINHAMENTO .......................................................................................................................................................... 135
FIGURA 13 (A) MEDIO FIXADA NO POSTE DA DISTRIBUIDORA ................................................................................... 136
FIGURA 13 (B) MEDIO FIXADA NO POSTE DA DISTRIBUIDORA ................................................................................... 137
FIGURA 13 (C) MEDIO FIXADA NO POSTE DA DISTRIBUIDORA ................................................................................... 138
FIGURA 14 DISPOSIES DOS ISOLADORES DO RAMAL DE LIGAO .......................................................................... 139
FIGURA 15 (A) RAMAL DE ENTRADA SUBTERRNEO ....................................................................................................... 140
FIGURA 15 (B) RAMAL DE ENTRADA SUBTERRNEOSOMENTE SOB VIA INTERNA DE CONDOMINIO ......................... 141
FIGURA 16 AFASTAMENTO MNIMO PARA ANCORAGEM DO RAMAL DE LIGAO ........................................................ 142
FIGURA 17 ANCORAGEM DO RAMAL DE LIGAO ............................................................................................................ 143
FIGURA 18 FIXAO DE CAIXAS PARA MEDIDORES ........................................................................................................ 144
FIGURA 19 FIXAO DE CAIXAS PARA MEDIDORES ........................................................................................................ 145
FIGURA 20 FIXAO DE CAIXAS PARA MEDIDORES ........................................................................................................ 146
FIGURA 21 FIXAO DE CAIXAS PARA MEDIDORES ........................................................................................................ 147
FIGURA 22 DISPOSIO DOS ELETRODUTOS .................................................................................................................. 148
FIGURA 23 MONTAGEM DAS CAIXAS PARA MEDIDORES MONOFSICOS ..................................................................... 149
FIGURA 24 MONTAGEM DAS CAIXAS PARA MEDIDORES POLIFSICOS ........................................................................ 150
FIGURA 25 MODELO DE CAIXA PARA UM CENTRO DE MEDIO .................................................................................... 151
FIGURA 26 MODELO DE CAIXASCOM MAIS DE UM CENTRO DE MEDIO ..................................................................... 152
FIGURA 27 MODELO DE CAIXA PARACENTRO DE MEDIO OCUPANDO DUAS PAREDES.......................................... 153
FIGURA 28 MODELO DE CAIXA PARA CENTRO DE MEDIO OCUPANDO TRES PAREDES ......................................... 154
FIGURA 29 SISTEMA DE EMERGNCIA .............................................................................................................................. 155
FIGURA 30 (A) POSTE PARTICULAR DE CONCRETO ARMADO ........................................................................................ 156
FIGURA 30 (B) POSTE PARTICULAR DE MADEIRA ............................................................................................................. 157
FIGURA 30 (C) POSTE PARTICULAR DE AO ..................................................................................................................... 158
FIGURA 30 (D) POSTE PARTICULAR EM CONCRETO ARMADO COM CAIXA DE MEDIO MONOFSICA ACOPLADA 159
FIGURA 31 CAIXAS DE PROTEO E DISTRIBUIO ........................................................................................................ 160
FIGURA 32 CAIXAS DE PASSAGEM PARA RAMAL DE ENTRADA SUBTERRNEO .......................................................... 161
FIGURA 33 ELETRODO DE ATERRAMENTO ....................................................................................................................... 162
FIGURA 34 ARMAO SECUNDRIA E SUPORTE ............................................................................................................. 163
FIGURA 35 ISOLADORES ..................................................................................................................................................... 164
FIGURA 36 TUBO PARA ATERRAMENTO ............................................................................................................................ 165
FIGURA 37 DETALHE DE ATERRAMENTO .......................................................................................................................... 166
OBJETIVO
Este Regulamento tem por objetivo padronizar e estabelecer as condies gerais para o fornecimento de
energia eltrica em tenso secundria de distribuio, atravs de rede area, s unidades consumidoras na
rea de concesso das empresas AES Sul Distribuidora Gacha de Energia S. A. CEEE-D - Companhia
Estadual de Distribuio de Energia Eltrica e RGE - Rio Grande Energia S.A. no Estado do Rio Grande do
Sul. Aplica-se tanto para projetos e/ou instalaes novas, como para reformas.
As disposies desta Norma visam:
a) Atender as consultas dos interessados no fornecimento de energia eltrica, quanto maneira de
obterem ligao;
b) Estabelecer as condies gerais de utilizao de energia eltrica;
c) Dar orientao tcnica para o projeto e execuo de entradas de servio de unidades
consumidoras, obedecendo a recomendaes da ABRADEE - Associao Brasileira de Empresas
Distribuidoras de Energia Eltrica, das normas da ABNT - Associao Brasileira de Normas
Tcnicas, bem como da legislao em vigor;
d) Orientar os consumidores, no implicando em qualquer responsabilidade das distribuidoras, com
relao qualidade e segurana dos materiais fornecidos por terceiros, bem como sobre os riscos e
danos propriedade. Os materiais fornecidos devem atender s exigncias do INMETRO e
observar o Cdigo de Defesa do Consumidor.
Este Regulamento pode, em qualquer tempo, sofrer alteraes por razes de ordem tcnica ou legal, motivo
pelo qual os interessados devem, periodicamente, consultar a distribuidora quanto a eventuais
modificaes.
Os rgos tcnicos da distribuidora encontram-se disposio dos interessados para prestar quaisquer
esclarecimentos tcnicos, julgados necessrios, para o fornecimento de energia eltrica.
REFERNCIAS NORMATIVAS
Na aplicao deste Regulamento, pode ser necessrio consultar as Normas da ABNT, Normas
Internacionais e Resolues da ANEEL, vigentes na poca da sua utilizao.
Os dispositivos deste Regulamento aplicam-se s condies normais de fornecimento de energia eltrica.
Os casos omissos ou aqueles que, pelas caractersticas excepcionais, exijam estudos especiais, devem ser
objetos de anlise e deciso por parte da distribuidora.
NBR 5410
NBR 5419
NBR 5597
NBR 5598
NBR 5624
NBR 6148
NBR 6231
NBR 6232
NBR 6248
NBR 6249
NBR 6323
NBR 6591
NBR 7285
NBR 7286
NBR 7287
NBR 7288
Outros:
Regulamento de Instalaes Consumidoras com Fornecimento em Tenso Primria de Distribuio (RIC
MT).
Regulamentao da ANEEL (Agncia Nacional de Energia Eltrica) - Condies gerais de fornecimento de
energia eltrica em vigncia.
TERMINOLOGIAS E DEFINIES
3.1
3.2
Barra de Proteo
3.3
3.4
3.5
Caixa de passagem
3.6
3.7
Caixa de medio
3.8
Carga instalada
Barra de cobre para a interligao do condutor de proteo das unidades consumidoras com o condutor de
proteo do eletrodo de aterramento.
Caixa metlica destinada a interligar circuitos, podendo conter as protees dos circuitos de interligao, o
barramento e os transformadores de corrente para medio.
Caixa metlica destinada a receber o ramal de entrada e as protees, podendo ainda conter o barramento
e os transformadores de corrente para medio.
Caixa metlica ou plstica anti-chama destinada a garantir a inviolabilidade das ligaes aos terminais de
cada medidor.
Soma das potncias nominais dos equipamentos eltricos instalados na unidade consumidora, em
condies de entrar em funcionamento, expressa em quilowatts (kW).
3.9
Cavidade de inspeo
Caixa ou tubo destinado a possibilitar a inspeo da haste e conexes dos condutores de aterramento e
proteo.
Circuito que interliga a Caixa de Distribuio ou a Caixa de Entrada de Distribuio com as Caixas de
Proteo ou entre Caixas de Proteo.
Circuito que interliga a Caixa de Entrada e Distribuio (CED) com a Caixa de Distribuio (CD) ou ainda
entre Caixas de Distribuio (CDs).
Condutor que interliga o eletrodo de aterramento primeira conexo com o condutor neutro da medio ou
Centro de Medio.
Condutor que liga as massas e os elementos condutores estranhos instalao ao eletrodo de aterramento
ou a um barramento de equipotencializao.
3.17 Consumidor
Pessoa fsica ou jurdica, de direito pblico ou privado, legalmente representada, que solicite o
fornecimento, a contratao de energia ou o uso do sistema eltrico distribuidora, assumindo as
obrigaes decorrentes deste atendimento (s) sua(s) unidade(s) consumidora(s), segundo disposto nas
normas e nos contratos.
3.18 Demanda
Soma das potncias eltricas instantneas solicitadas ao sistema eltrico, expressa em quilowatts (kW),
quilovolt-ampre-reativo (kVAr) ou quilovolt-ampre (kVA).
3.19 Disjuntor
Dispositivo utilizado para limitar as sobretenses transitrias e escoar os surtos de corrente originrios de
descargas atmosfricas em redes de energia.
3.22 Distribuidora
Agente titular de concesso ou permisso federal para prestar o servio pblico de distribuio de energia
eltrica.
Edificao que possua mais de uma unidade consumidora, como salas, apartamentos, lojas, e/ou
dependncias semelhantes, e que disponha de rea de uso comum com utilizao de energia eltrica.
Energia eltrica que pode ser convertida em outra forma de energia, expressa em quilowatt-hora (kWh).
Energia eltrica que circula continuamente entre os diversos campos eltricos e magnticos de um sistema
de corrente alternada, sem produzir trabalho, expressa em quilovoltamprereativohora (kVArh).
Demarcaes que separam a propriedade do consumidor da via pblica, de reas de uso comum (no caso
de condomnios horizontais) e dos terrenos adjacentes de propriedade de terceiros, no alinhamento
designado pelo poder pblico.
Acesso de empregados e prepostos da distribuidora ao local da medio, para fins de ligao, suspenso
de fornecimento, leitura e inspees necessrias, a qualquer tempo.
3.30 Medidor
Aparelho instalado pela distribuidora, com o objetivo de medir e registrar grandezas eltricas.
A origem da instalao de Baixa Tenso est localizada junto proteo geral da unidade consumidora.
3.32 Pontalete
Suporte instalado no muro ou prdio do consumidor, quando o prdio estiver localizado no limite da
propriedade com alinhamento da via pblica, observada a convenincia tcnica da distribuidora, com a
finalidade de ancorar e fixar o ramal de ligao, servindo para instalar o ramal de entrada.
Ponto de conexo do sistema eltrico da distribuidora com as instalaes eltricas da unidade consumidora,
at o qual a distribuidora responsvel pelo fornecimento de energia eltrica, participando dos
investimentos necessrios e responsabilizando-se pela execuo dos servios, operao e manuteno,
caracterizando-se como limite de responsabilidade de fornecimento.
Poste instalado na propriedade do consumidor com a finalidade de ancorar o ramal de ligao, bem como a
instalao de medio individual, com fabricantes devidamente cadastrados junto distribuidora.
Poste instalado na propriedade do consumidor com a finalidade de ancorar o ramal de ligao, bem como a
instalao de medio individual, com fabricantes devidamente cadastrados junto distribuidora.
Poste instalado na propriedade do consumidor com a finalidade de ancorar o ramal de ligao, bem como a
instalao da medio, podendo ainda sustentar linhas de comunicao e dados.
Poste instalado na divisa entre duas propriedades com a finalidade de ancorar o ramal de ligao, bem
como a instalao de duas medies individuais monofsicas.
Quadro destinado instalao dos medidores, seus acessrios e dispositivos de proteo, localizado em
centro(s) de medio.
Conjunto de condutores e acessrios instalados pelo consumidor entre o ponto de entrega e a medio. No
caso de centro(s) de medio, at a proteo geral do painel de medidores.
Conjunto composto por instalaes, ramal de entrada, equipamentos eltricos, condutores e acessrios,
caracterizado pelo recebimento de energia eltrica em apenas um ponto de entrega com medio
individualizada, correspondente a um nico consumidor e localizado em uma mesma propriedade ou em
propriedades contguas.
4
4.1
Aplica-se nas ligaes das unidades consumidoras com carga instalada at 75kW e edificaes de mltiplas
unidades consumidoras.
4.2
Tenso de fornecimento
4.3
Toda unidade consumidora deve ser identificada, por nmero fornecido pelo rgo competente do poder
pblico municipal, mediante a utilizao de materiais apropriados, indelvel e de fcil visualizao.
4.4
Consulta prvia
Antes de construir ou adquirir os materiais para a execuo da entrada de energia, o interessado deve
consultar a distribuidora, previamente, visando obter informaes orientativas a respeito das condies de
fornecimento de energia eltrica.
Para prdios de mltiplas unidades, o responsvel tcnico deve requisitar junto distribuidora, informaes
a respeito do tipo de fornecimento de energia edificao.
4.4.1 Reforma
Em casos de reforma, este Regulamento pode ser aplicado em parte ou no seu todo, dependendo de
consulta prvia distribuidora com relao s condies tcnicas e/ou de segurana.
4.5
O ponto de entrega de energia eltrica deve situar-se na conexo do ramal de ligao com o ramal de
entrada, ressalvados os seguintes casos:
a) Para unidades consumidoras e edificaes de mltiplas unidades consumidoras atendidas
diretamente pela rede da via pblica em baixa tenso, com entrada subterrnea, o ponto de entrega
situar-se- na conexo deste ramal com a rede area, sendo vedada a travessia em via pblica;
b) O ponto de entrega pode situar-se em local diverso, quando se tratar de fornecimento unidade
consumidora atendida mediante a alocao de recursos financeiros a ttulo de subveno
econmica, caso em que deve ser observado o estabelecido no ato que instituir programa de
eletrificao correspondente;
c) Havendo convenincia tcnica por parte da distribuidora, o ponto de entrega pode situar-se dentro
do imvel em que se localizar a unidade consumidora.
Notas:
1 Quando existir propriedade de terceiros, em rea urbana, entre a via pblica e a propriedade onde
estiver localizada a unidade consumidora, o ponto de entrega situar-se- no limite da via pblica com a
primeira propriedade. Para utilizao desta modalidade de fornecimento consultar a distribuidora.
3
4
5
6
7
4.6
10
Quando a unidade consumidora, em rea rural, for atendida em tenso secundria de distribuio, o
ponto de entrega situar-se- no local de consumo, ainda que dentro da propriedade do consumidor,
observadas as normas e padres da distribuidora.
Quando tratar-se de condomnio horizontal, onde a rede eltrica interna no seja de propriedade da
distribuidora, o ponto de entrega situar-se- no limite da via pblica com o condomnio horizontal.
Quando tratar-se de condomnio horizontal, onde a rede eltrica interna seja de propriedade da
distribuidora, o ponto de entrega situar-se- no limite da via interna com a propriedade onde estiver
localizada a unidade consumidora.
Edificaes de mltiplas unidades devem ser atendidos por uma nica entrada de energia e ter um s
ponto de entrega.
Condomnios horizontais e verticais devem ser atendidos por uma nica entrada de energia.
Havendo interesse do consumidor em ser atendido por ramal de entrada subterrneo a partir de poste
de propriedade da distribuidora, observadas a viabilidade tcnica, o ponto de entrega se situar na
conexo deste ramal com a rede da distribuidora, desde que esse ramal no ultrapasse propriedades
de terceiros ou vias pblicas, exceto caladas
Limites de fornecimento
O fornecimento deve ser efetuado em tenso secundria nas ligaes individuais com carga instalada at
75kW.
Para o atendimento de edificaes de mltiplas unidades consumidoras com demanda calculada superior a
115kVA, deve ser prevista em projeto uma rea do condomnio para o(s) posto(s) de transformao de uso
exclusivo, conforme RIC de MT Regulamento de Instalaes Consumidoras em Mdia Tenso.
Nota:
Por razes de ordem tcnica, esttica e/ou de segurana a critrio da distribuidora, independente das
condies acima, podem ser estabelecidos valores diferentes aos limites mencionados.
4.7
Aparelhos e Lmpadas
Potncia (W)
Chuveiro
5.000
Televisor
200
Refrigerador
200
Aspirador de p
1.000
1.500
1
1
1
1
2
8
5
1.500
350
400
1.300
200
800
300
12.750
11
No ANEXO J so representados os limites, por faixa de carga instalada ou de demanda, bem como os limites para
a ligao de motores ou aparelhos de solda, para cada tipo de fornecimento.
Notas:
1 Em casos especiais, as instalaes podem possuir aparelhos que requeiram nmero de fases superior ao do
tipo correspondente a sua carga instalada.
2 Mesmo sendo especificado o fornecimento a dois condutores, permite-se a instalao de padro polifsico,
caso o consumidor tenha previso de aumento de carga.
3 Os limites para aparelhos de eletro-galvanizao, mquinas de solda, geradores, raios-X, etc., (carga de
flutuao brusca de tenso), esto sujeitos a estudo nos diversos tipos de fornecimento.
4 As unidades consumidoras atendidas por duas ou trs fases devem ter suas cargas distribudas entre as fases
de modo a obter-se o maior equilbrio possvel.
5
5.1
O interessado deve entrar em contato com a distribuidora, informando a carga instalada discriminada, o endereo
onde pretende que seja efetuada a ligao e os dados de identificao do consumidor, informaes referentes a
natureza da atividade desenvolvida na unidade consumidora, finalidade da utilizao da energia eltrica. A
ligao depende de verificao e/ou estudo da rede, se:
a) A carga instalada exigir;
b) O imvel, onde se encontra a unidade consumidora, estiver afastado a mais de 30 metros da rede de
distribuio;
c) Quando a configurao da rede de distribuio da distribuidora no for compatvel com o tipo de
fornecimento solicitado;
d) Existirem aparelhos com carga de flutuao brusca de tenso, como mquinas de solda, gerador,
aparelhos de eletrogalvanizao, raios-X e outros aparelhos;
e) Envolver travessia de via pblica (pista de rolamento) com duto subterrneo.
Notas:
1 A distribuidora deve informar sobre a necessidade de execuo de servios nas redes e/ou instalao de
equipamentos de proteo e/ou de transformao, conforme a carga solicitada.
2 O atendimento do pedido de ligao no transfere a responsabilidade tcnica para a distribuidora, quanto ao
projeto e execuo das instalaes eltricas internas da edificao.
3 Apesar de no ser exigncia da distribuidora para efetivar a ligao, recomendvel que os consumidores
instalem dispositivos de proteo contra a falta e inverso de fases, proteo a corrente diferencial-residual
(DR), conforme NBR 5410.
4 Toda a instalao ou carga suscetvel de ocasionar perturbaes ao fornecimento regular a outras unidades
consumidoras, somente deve ser ligada aps a prvia concordncia da distribuidora, que deve providenciar, a
expensas do consumidor, alteraes no sistema eltrico, visando manter o fornecimento adequado a todos os
consumidores da rea.
5.2
12
5.3
Ligao definitiva
5.4
Gerao prpria
5.5
Condies no permitidas
a) Extenso das instalaes eltricas de uma unidade consumidora para alm dos seus limites ou
propriedade de terceiros;
b) Paralelismo simultneo de geradores particulares para atendimento de emergncia com o sistema da
distribuidora;
c) Aumento da capacidade do disjuntor, alm do limite correspondente a sua categoria de fornecimento, sem
a prvia autorizao da distribuidora;
13
d) Utilizao das tubulaes destinadas aos condutores que transportam energia eltrica para quaisquer
outras finalidades;
e) Interferncia de pessoas estranhas no(s) equipamento(s) da distribuidora;
f) Utilizao de aparelhos de solda a transformador monofsicos, com potncia nominal superior a 2kVA;
g) Alimentao de uma mesma propriedade com mais de uma entrada de servio, exceto mediante prvia
concordncia da distribuidora.
6.1
Localizao da medio
14
6.2
Instalao da medio
a) Em cada unidade consumidora;
b) Em unidade consumidora que for subdividida, as instalaes eltricas internas devem ser adaptadas, pelo
interessado, de forma a permitir uma medio para cada unidade que resultar da subdiviso;
c) Em unidades consumidoras unificadas, as instalaes eltricas internas devem ser adaptadas, pelo
interessado, de forma a permitir uma nica medio;
d) Em edificaes de mltiplas unidades consumidoras, a rea de uso comum deve ter medio prpria e ser
de responsabilidade do condomnio, da administrao ou um dos proprietrios da edificao;
e) Para instalao de mais de um centro de medio, o mesmo deve prever o atendimento de mais de
quinze unidades consumidoras. Em cada centro deve ser previsto um nmero mnimo de oito unidades
consumidoras.
Notas:
1 Os medidores e equipamentos, destinados medio, so propriedade da distribuidora, ficando a seu critrio
a instalao daqueles que julgar necessrios, bem como sua substituio quando considerada conveniente, e
so instalados, pela distribuidora, aps vistoria e aprovao da entrada de servio.
2 A instalao eltrica de cada unidade consumidora deve obedecer legislao vigente, normas da ABNT e
padres da distribuidora. Quando considerada em desacordo ou prejudicial aos servios, deve ser adequada
aos padres vigentes.
3 O consumidor deve permitir, a qualquer tempo, o livre e fcil acesso dos representantes da distribuidora,
devidamente credenciados e identificados, instalao eltrica de sua propriedade, fornecendo os dados e
informaes, referentes ao funcionamento da instalao e aparelhos eltricos.
PROJETO
7.1
15
Apresentao
O projeto deve ser apresentado, num prazo mximo de 180 dias aps o pedido da ligao provisria, em trs vias
(padro ABNT, dobradas em formato A4) com a rea acima do selo reservada para utilizao da distribuidora.
Notas:
1 Os profissionais responsveis pelos projetos e/ou execues devem ser habilitados e ter suas atribuies
especficas anotadas em carteiras expedidas pelos Conselhos Regionais habilitadores.
2 O projeto, as especificaes e a construo da instalao eltrica interna da edificao devem estar de acordo
com as normas da ABNT.
3 O projeto deve atender NR 10.
16
7.1.2 Anlise
Aps anlise disponibilizado uma via do projeto ao responsvel tcnico ou contratante. Eventuais modificaes
devem ser realizadas pelo responsvel tcnico.
Nota:
A entrada de servio que necessitar de projeto eltrico deve ser executada aps a liberao do mesmo pela
distribuidora.
7.1.3 Validade
O projeto vlido por 02 (dois) anos a contar da data de liberao. Caso no ocorra a ligao definitiva neste
prazo, deve ser submetido distribuidora para revalidao, sujeitando-se s possveis alteraes sofridas nos
padres, neste perodo.
7.2
Clculo da demanda
Na unidade consumidora com carga instalada superior a 15kW (220/127V) ou 25kW (380/220V),deve ser
calculada a demanda para dimensionar o condutor dos circuitos de distribuio e alimentador.
Nota:
A demanda mnima considerada por unidade consumidora, quando calculada, deve ser:
a) Para 220/127V 15 kVA;
b) Para 380/220V 25 kVA.
D(kVA) = (a + b + c + d + e + f)
Sendo:
a= Demanda de iluminao e tomadas, calculada conforme ANEXO D;
b=Demanda dos aparelhos para aquecimento (chuveiros, aquecedores, fornos, foges, etc.), calculada
conforme ANEXO I;
c= Demanda dos aparelhos de condicionador de ar, tipo janela, calculada conforme ANEXOS E e F,
(unidade em kVA);
d= Demanda das unidades centrais de condicionadores de ar, calculadas a partir das respectivas
correntes mximas totais (valores fornecidos pelos fabricantes), considerando o fator de demanda de
100%;
e= Demanda dos motores eltricos e mquinas de solda a motor, calculada conforme ANEXO G;
f= Demanda das mquinas de solda a transformador, aparelhos de eletrogalvanizao e de raios-X,
calculada conforme ANEXO H.
Nota:
Em reformas, os dados de placa dos aparelhos podem ser considerados para elaborao do clculo da demanda.
4
5
6
17
No caso de previso de aparelho condicionador de ar tipo split, com potncia at 3.600W ou 4 kVA (30.000
BTU/h), considerar como sendo de janela. Para potncias superiores, considerar como aparelho
condicionador de ar central.
Estas potncias se referem previso para motores, devendo a diferena entre estes valores e a carga
instalada em motores (kVA) e/ou condicionadores de ar tipo janela (kVA), quando positiva, ser considerada
como um nico motor e convertida em CV, para efeito de utilizao da tabela do ANEXO G. Adota-se a
potncia em CV mais prxima do valor convertido e sua respectiva carga em kVA.
A potncia de aparelho reserva, no deve ser considerada.
No clculo da potncia para motores, considerar 1 HP = 746 Watts e 1 CV = 736 Watts.
A previso de aumento de carga pode ser considerada.
18
8.1
Para atendimento de entrada de energia com demanda at 47kVA em 220/127V e 82kVA em 380/220V. Na rea
de concesso da CEEE-D, para atendimento de entrada de energia com demanda at 57kVA em 220/127V e
99kVA em 380/220V
i)
19
Os condutores devem ficar fora do alcance de janelas, sacadas, sadas de incndio, terraos ou locais
anlogos, mantendo um afastamento mnimo como mostra a figura 16.
8.1.2 Ancoragem
Na ancoragem area dos condutores deve-se utilizar:
a) Armao secundria de um estribo com isolador tipo roldana 76x80mm, para condutores multiplex, em
poste ou parede;
b) Armao secundria, liga de alumnio, de dois estribos com isolador tipo roldana 76x80mm, para
condutores singelos, em poste ou parede, nas regies com acentuado ndice de corroso (carbonferas ou
litorneas);
c) Isolador castanha 60x40mm, para condutores multiplex em pontaletes e para condutores singelos em
postes e pontaletes nas regies com acentuado ndice de corroso (carbonferas ou litorneas);
Notas:
1 Para fixao das armaes ou isoladores, consultar figuras 16 e 17.
2 Para armaes secundrias dispostas em fachadas deve ser apresentado documento de Responsabilidade
Tcnica (fornecido pelo Conselho Regional habilitador, devidamente quitado e assinado)do projeto e execuo
da fixao.
3 No ponto de ancoragem em fachadas deve ser observada a altura mxima de 7,50m.
4 Para ramal de ligao com seo superior a 25mm de cobre e 35mm de alumnio, exige-se ramal de entrada
subterrneo. Na rea de concesso da CEEE-D exige-se ramal de entrada subterrneo quando a seo do
ramal de ligao for superior a 35mm de cobre e 50mm de alumnio.
20
As junes entre os eletrodutos e as caixas (de medio, CPs, CEDs, etc.) devem ser executadas por
meio de buchas de proteo e arruelas. Quando sujeitos a intemprie, devem ser vedadas com massa de
calafetar, silicone ou espuma de poliuretano expansvel (ver figura 22);
g) As mudanas de direo do eletroduto podem ser no mximo trs e devem utilizar curva de raio longo de
90;
h) Os eletrodutos no devem localizar-se no interior de vigas e colunas;
i) Quando embutido consultar Nota 6 do ANEXO J.
f)
8.2
Para atendimento de entrada de energia com demanda superior a 47kVA em 220/127V e 82kVA em 380/220V e
facultativo para limites inferiores. Na rea de concesso da CEEE-D, para atendimento de entrada de energia com
demanda superior a 57kVA em 220/127V e 99kVA em 380/220V e facultativo para limites inferiores.
8.2.3 Eletrodutos
a) Os eletrodutos devem ter dimetro nominal mnimo de 50mm;
b) Junto ao poste o eletroduto deve ser rgido de ao carbono, galvanizado a fogo, classe mdia, pesada,
ou extra, devidamente aterrado. Para o aterramento deve ser utilizado conector bimetlico e sua fixao
com o mesmo material do eletroduto. (ver figura 15);
c) Em regies com acentuado ndice de corroso (litorneas ou carbonferas), os eletrodutos devem ser de
material aluminizado tipo pesado;
21
d) Os cabos multipolares e unipolares devem ser protegidos, respectivamente, at a altura mnima de 2,70m
e 5,70m do solo;
e) No passeio pblico o eletroduto deve ser de ao galvanizado a fogo, tipo pesado, PVC flexvel, rgido
rosquevel ou soldvel, instalado a uma profundidade mnima de 0,30m;
f) Nas travessias de pistas de rolamento (somente em vias internas de condomnios)e entradas de veculos
pesados, o eletroduto deve ser de ao galvanizado a fogo. Podem ser usados eletrodutos de PVC flexvel
ou rgido (rosquevel ou soldvel), protegidos por envelope de concreto. Nestes casos deve-se observar a
profundidade mnima de 0,60m (ver figura 15);
g) Em instalaes aparentes, os cabos devem ser protegidos ao longo de paredes e/ou teto por meio de
eletroduto rgido de ao-carbono, esmaltado ou galvanizado, espessura de parede classe "mdia",
"pesada" ou "extra com acabamento nas extremidades. Nos pavimentos em que os eletrodutos forem
instalados paralelos as vigas, apoiados e protegidos pelas mesmas, pode se utilizar eletroduto de PVC
rgido.
Notas:
1 O eletroduto junto ao poste deve ser identificado com o nmero do prdio a ser ligado, utilizando material no
corrosivo, fixado na extremidade superior do mesmo.
2 O eletroduto junto ao poste deve ter na extremidade superior bucha rosquevel para acabamento.
3 No passeio pblico e nas travessias de pista de rolamento (somente em vias internas de condomnios), os
eletrodutos devem ser sinalizados com uma fita indicativa de "condutor de energia eltrica", respectivamente,
a 0,15m e a 0,30m acima do eletroduto, em toda a sua extenso, conforme NBR 5410.
4 Entre caixas de passagem, o trecho mximo de eletrodutos deve ser 30m. Em deflexo deve se prever caixa
de passagem.
8.3
Aspectos construtivos
22
8.3.4 Pontalete
Utiliza-se para as finalidades descritas no item 3.32, tendo como base a figura 12 e o dimensionamento conforme
ANEXO K.
Nota:
Em regies com acentuado ndice de corroso (carbonferas e litorneas), o pontalete deve ser revestido por duto
de PVC.
8.3.5 Responsabilidades
Aps o ponto de entrega, responsabilidade do consumidor, manter a adequao tcnica e de segurana nas
instalaes internas da unidade consumidora.
Quando constatada qualquer deficincia tcnica e/ou de segurana, o consumidor notificado por escrito, para
providenciar os reparos necessrios no prazo estabelecido.
O consumidor responsvel pelos equipamentos da distribuidora quando instalados dentro da sua propriedade,
devendo responder por eventuais danos ocasionados aos mesmos e garantir o livre e fcil acesso da distribuidora.
9
9.1
MEDIO
Tipos
23
Destinada a unidades consumidoras atendidas a dois, trs ou quatro condutores, com demanda igual ou
inferior a 38kVA em 220/127V e 66kVA em 380/220V.
b) Medio indireta
Destinada a unidades consumidoras atendidas a quatro condutores com demanda superior aos limites
estabelecidos na medio direta.
9.2
9.2.1 Material
Devem ser confeccionadas em chapa de ao oleada ou zincada, alumnio, resinas polister reforadas com fibra
de vidro, policarbonato, polietileno, polister ou madeira.
Notas:
1 As caixas confeccionadas com madeira de cerne aplainada devem ser pintadas, interna e externamente, com
tinta a leo, esmalte sinttico ou envernizadas. Quando sujeito a intemprie, devem ter a face superior
revestida com chapa metlica.
2 Em regies com acentuado ndice de corroso (carbonferas e litorneas), no deve-se utilizar caixa para
medio confeccionada em chapa de ao oleada ou zincada.
3 As caixas modelos CLI e CLE no devem possuir rebites em locais que permitam acesso ao compartimento
lacrvel.
4 A utilizao das caixas modelos CPO, CPOL, CPOMD e CPOM em entradas de energia est condicionada ao
cadastro e liberao do fabricante pelas distribuidoras.
9.2.2 Modelos
Os modelos devem ser:
a) CI Caixa Interna;
b) CLI Caixa Lacrvel Interna;
c) CE Caixa Externa;
d) CLE Caixa Lacrvel Externa;
e) CPO Caixa de Policarbonato ou Polister;
f) CPOL Caixa de Policarbonato ou Polister com Lente;
g) CPOMD Caixa de Policarbonato ou Polister com Mdulo para Disjuntor independente;
h) CPOM Caixa de Policarbonato ou Polister Modulada.
Notas:
1 Os modelos CI e CLI devem ser usados embutidos em parede, muro ou mureta.
2 Os modelos CE e CLE devem ser usados em locais sujeitos a intemprie, junto ao poste e parede.
3 Os modelos CLI, CLE, CPO, CPOL, CPOMD e CPOM dispensam o uso de CP.
4 Os modelos CPO, CPOMD e CPOM podem ser usados embutidos ou ao tempo. Quando frontal, no
alinhamento com a via pblica, necessariamente embutidos.
5 O modelo CPOL deve ser usado nas situaes previstas no item 6.1.3.
6 Os modelos CPO, CPOMD e CPOM no devem ser usados quando os condutores do ramal de entrada forem
2
de seo superior a 25mm .
7 A utilizao de Caixas de Policarbonato Moduladas, (CPOM), em situaes no previstas nos agrupamentos
do ANEXO Z, depende de apresentao de liberao projeto especifico, com detalhamento das caixas bem
como dos componentes necessrios para a sua montagem.
9.2.3 Aplicao
O uso deve ser de acordo com:
a) Medio individual conforme ANEXO B
- Tamanho1 ou 1A para unidade consumidora atendida a dois condutores;
- Tamanho2 ou 2A para unidade consumidora atendida a trs ou quatro condutores, com medio
direta;
24
9.2.4 Fixao
As caixas devem ser fixadas, conforme figuras 18 a 21.
9.2.5 Instalao
Para a instalao observar:
a) A caixa para medio individual deve ser instalada de modo que a parte superior da face frontal fique a
uma altura de 1,60m com uma tolerncia de +/- 0,15m em relao ao piso acabado;
b) A caixa para agrupamento no pertencente edificao de mltiplas unidades consumidoras, com as
combinaes 1 a 3, figuras A e B, constantes do ANEXO Z, deve ser instalada de modo que a parte
superior da face frontal fique a uma altura de 1,60m com uma tolerncia de +/- 0,15m em relao ao piso
acabado. As demais combinaes constantes do mesmo anexo devem obedecer s cotas das respectivas
figuras;
c) O(s) centro(s) de medio pertencente(s) edificao de mltiplas unidades consumidoras, deve(m) ser
instalado(s) de modo que a aresta inferior fique a uma altura mnima de 0,40m e a aresta superior a uma
altura mxima de 2,20m, em relao ao piso acabado;
d) O(s) centro(s) de medio pertencente(s) edificao de mltiplas unidades e consumidoras, com dois
nveis de distribuio (alinhamento de CPs), deve observar uma altura mxima de 1,8m em relao ao
piso acabado.
9.2.6 Conservao
As caixas e compartimentos destinados instalao dos medidores devem ser mantidos em bom estado de
conservao e limpeza, sendo proibida a sua utilizao para outras finalidades.
9.3
Os modelos das caixas de proteo encontram-se na figura 31, sendo instaladas de acordo com as seguintes
indicaes:
a) CP1
Medio individual ou agrupamento no pertencente edificao de mltiplas unidades consumidoras,
atendidas a dois condutores.
b) CP2
Medio direta individual atendida a trs ou quatro condutores;
Medio direta em edificao de mltiplas unidades consumidoras, independente do nmero de
condutores.
c) CP4
Medio indireta.
9.4
25
Notas:
1 Suas dimenses devem ser compatveis com a necessidade dos circuitos de distribuio.
2 As dimenses mnimas padronizadas encontram-se na figura 31.
9.5
26
q) Em painis de medidores no abrigados deve-se prever uma pingadeira, com avano frontal mnimo de 10
cm, observandose os cdigos de postura dos Municpios;
r) Os centros de medio devem possuir espao livre frontal de 1,20m. Nos centros de medio com mais
de uma face deve ser previsto espao livre mnimo de 1,20m entre as faces;
s) Os centros de medio tipo armrio localizados em garagens e/ou estacionamento de veculos devem
possuir espao livre frontal de 1,20m com barreira de proteo neste limite.
10 PROTEO GERAL
10.1 Disjuntor geral
O disjuntor geral deve assegurar a proteo do ramal de entrada ou, no caso de edificao com posto de
transformao interna, dos cabos que interligam o transformador ao disjuntor geral e no deve interromper o
fornecimento de energia ao sistema de emergncia.
A corrente nominal do disjuntor geral deve ser igual ou superior corrente solicitada pela demanda calculada
conforme item7.2 e no deve ultrapassara capacidade de conduo de corrente dos condutores do ramal de
entrada.
Nos locais onde a tenso usual de fornecimento for 220/127V o disjuntor geral deve possuir capacidade de
interrupo mnima de 10kA, onde a tenso usual de fornecimento for 380/220V o disjuntor geral deve possuir
capacidade de interrupo mnima de 5kA, exceto para o caso de edificao com posto de transformao interno,
onde o dimensionamento deve ser efetuado atravs do clculo de curto circuito.
Quando a alimentao for a partir do posto de transformao interno, o disjuntor geral deve estar intertravado
eletricamente com a seccionadora de mdia tenso.
Disjuntores com corrente nominal at 63A devem ser certificados pelo INMETRO.
27
a) O primeiro, a montante, no incio do circuito, com capacidade de conduo igual ou inferior a do condutor
do referido circuito;
b) O segundo, a jusante, no final do circuito. Este pode ser dispensado, se o disjuntor a montante estiver
instalado na mesma sala (espao fsico) e seja visvel ao operador;
c) Para o dimensionamento do disjuntor a montante, multiplica-se a corrente nominal do disjuntor a jusante
pelo fator de 1,20. Havendo dificuldade de coordenao e seletividade, o disjuntor a jusante pode ser
substitudo por uma chave seccionadora tripolar, abertura sob carga (sem fusvel).
Derivando da CED, admite-se um ou mais circuitos de interligao, cada circuito ter derivaes, e desta forma
alimentar outros centros de medio. Neste caso, os condutores das derivaes devem ter no mnimo a mesma
seo dos condutores do circuito principal.
As conexes das derivaes devem ser acondicionadas em CD (preferencialmente localizadas no centro de
medio), realizadas com conector tipo parafuso fendido de cobre ou bimetlico, isolados com fita de autofuso e
protegidos por fita isolante.
Exemplo 1 Circuito de interligao com derivaes:
Sistema de
Emergncia
CD1
CD2
CD3
Desligamento
distncia
Observar
Nota 4
CED
Sistema de
Emergncia
CED
Obs.:
As interligaes podem utilizar a combinao dos dois exemplos acima.
Notas:
1 Os disjuntores instalados na CED ou CDs devem ter alavanca de acionamento exposta.
2 Os disjuntores devem ser energizados, preferencialmente, pela parte inferior, quando isto no for possvel
(especificao do fabricante), deve-se instalar na tampa da CED ou CD placa de acrlico com a advertncia:
ATENO! Disjuntor energizado pela parte superior.
3 Em agrupamento com at 4 consumidores, no pertencente a edificao de mltiplas unidades consumidoras,
com ligao individual a dois condutores, pode ser dispensada a instalao do disjuntor geral (ver ANEXO Z
fig. A e B).
4 A instalao do dispositivo de comando de desligamento distncia (DDD), vedada, quando a alimentao
for a partir do posto de transformao interno. Este dispositivo deve localizar-se prximo entrada principal do
28
prdio, em caixa com tampa de vidro, altura de 1,50m com tolerncia de + 0,10m em relao ao piso acabado.
No caso de sinistro, uma vez rompido o vidro e acionado o dispositivo, deve interromper o fornecimento de
energia de todo o prdio, exceto o sistema de emergncia quando houver (ver detalhe nas figuras 25 a 28).
Este dispositivo pode ser dispensado se o disjuntor geral satisfizer, simultaneamente, as seguintes condies:
- Localizar-se fora do cubculo;
- Distar menos de 5 metros da entrada principal;
- Localizar-se no pavimento trreo;
- Inexistir abertura entre a entrada principal do prdio e o centro de medio.
10.5 Aterramento
O eletrodo de aterramento pode ser do tipo cantoneira de ao zincado, haste de cobre, ao zincado ou ao
revestido de cobre, comprimento 2000mm ou 2400mm. Permite-se usar outros tipos de eletrodo, desde que
atenda a NBR 5410, conforme ANEXO A, e liberados pela distribuidora no momento da vistoria da entrada de
energia. A utilizao de canalizao de gua, gs, etc. vedada para aterramento do condutor neutro.
O valor da resistncia de aterramento no deve ser superior a 25 ohms, em qualquer poca do ano. No caso de
no ser atingido esse limite com eletrodo constitudo de nica haste, deve-se utilizar quantas forem necessrias,
distanciadas dois metros, no mnimo, e interligadas atravs de condutor com seo mnima 16mm.
29
11 VIGNCIA
Este regulamento entra em vigor a partir de 01 de setembro de 2012 e revoga a verso 1.3 em noventa (90) dias.
ANEXOS
Observaes
Tubo de ao zincado
Perfil de ao zincado
Cantoneira de
20mm
x 20mm x 3mm com 2,40m de
comprimento
H aste de ao zincado
H aste de cobre
Fita de cobre
Fita de ao galvanizado
C abo de cobre
C abo de ao zincado
C abo de ao cobreado
31
32
Este anexo tem por objetivo estabelecer as condies mnimas para a fabricao de caixas de medio com
utilizao em entrada de energia de unidade consumidora, atendida em tenso secundria, pela rede da
distribuidora.
MATERIAIS
As caixas devem ser confeccionadas em chapa de ao oleada ou zincada, alumnio, resinas de polister
reforadas com fibra de vidro, policarbonato, polietileno ou madeira.
DISPOSIES GERAIS
33
TABELA
Dimenses
TAMANHO
MODELO
1
1A
2
2A
3
4
5
7
8
9
10
11
CI - CE
CLI - CLE
CI - CE
CLI - CLE
CI - CE
CI - CE
CI - CE
CI - CE
CI - CE
CI - CE
CI - CE
CI - CE
Fornecimento
Monofsica
Polifsica
Monofsica
Polifsica
Nota:
Medidas internas.
MODELO
CPO / CPOL
CPO / CPOL
CPOM
CPOM
A
30
30
60
50
80
60
60
150
120
90
120
130
MEDIDAS (cm)
B
40
30
60
50
60
40
80
130
90
120
130
120
A
20
28
25
33
MEDIDAS (cm)
B
33
53
30
45
C
15
15
24
18
24
15
15
24
26
26
26
26
C
14
23
16
20
USO INTERNO
CLI
TAMANHOS
1A e 2A
C
CE
CI
TAMANHOS
1e2
TAMANHO 3
MEDIO INDIRETA
CI
MEDIO INDIRETA
CE
130
TAMANHO 7
24
150
CPO
CPOL
00
UV
?
PC
Nota:
Para determinar o tamanho, consulte item 9.2.3.
34
TAMANHO 5
B
TAMANHO
3e4
TAMANHO 8
TAMANHO 9
TAMANHOS
10 e 11
Nota:
Para determinar o tamanho, consulte item 9.2.3.
35
VISTA FRONTAL
VISTA SUPERIOR
Notas:
1 Material de policarbonato e polister.
2 Medidas em centmetro.
VISTA LATERAL
VISTA INFERIOR
36
VISTA FRONTAL
VISTA SUPERIOR
Notas:
1 Material de policarbonato e polister.
2 Medidas em centmetro.
VISTA LATERAL
VISTA INFERIOR
37
VISTA FRONTAL
VISTA LATERAL
VISTA SUPERIOR
VISTA INFERIOR
Notas:
1 Material de policarbonato e polister.
2 Medidas em centmetro.
38
VISTA FRONTAL
VISTA SUPERIOR
Notas:
1 Material de policarbonato e polister.
2 Medidas em centmetro.
VISTA LATERAL
VISTA INFERIOR
39
40
8
12
8
3
20
Vidro
40
18
40
12
CAIXA INTERNA - CI
15
3
30
CAIXA EXTERNA CE
32
8
12
20
18
Vidro
38
40
12
20
30
15
Notas:
1 Marca para furao: Duas estampas, uma com 2,6cm circundada por outra de 4,6cm de dimetro para
passagem dos eletrodutos. Para o eletroduto de aterramento uma estampa com 2,2cm de dimetro.
2 A caixa fabricada em chapa de metal deve possuir terminal para aterramento.
3 Medidas em centmetros.
CAIXA INTERNA - CI
12
20
18
Vidro
40
40
12
Massa para
Vedao
30
2
15
CAIXA EXTERNA CE
Proteo de metal
no ferroso
36
23
18
12
20
Vidro
40
12
Massa para
Vedao
2
30
Nota:
Medidas em centmetros.
2
15
41
ver detalhe
1
fixao do vidro
e vedao
dobradia
vidro 4mm
parafuso
fixo
M - 8 / 15 mm
fechadura ou trinco
marca p/
furao
parafuso p/fixao
da moldura
CORTE BB
CORTE CC
parafuso fixo
M-8 / 15mm
dispositivo p/ lacre
arruela
marca p/ furao
DETALHE
1
DETALHE 2
ver detalhe 2
MOLDURA
CORTE DD
42
VISTA ABERTA
PORTA DE CORRER
43
44
FURAO DA CAIXA
DETALHE 1
Ver detalhe 1
Ver detalhe 2
30x30x1,4
DETALHE 2
Notas:
1 Marca para furao: Duas estampas, uma com 2,6cm circundada por outra de 4,6cm de dimetro para
passagem dos eletrodutos. Para o eletroduto de aterramento uma estampa com 2,2cm de dimetro.
2 A caixa fabricada em chapa de metal deve possuir terminal para aterramento.
3 Medidas em centmetros.
VISTA FECHADA
furo p/ o suporte
da caixa 8mm
18x28x14
furo p/ o suporte
da caixa 8mm
45
VISTA FRONTAL
fixao do vidro
e vedao
dobradia
vidro 4mm
marca p/
furao
parafuso
fixo
M - 8 / 15 mm
A
marca p/
furao
fechadura ou trinco
CORTE CC
CORTE BB
marca p/ furao
furao p/ aterramento
parafuso fixo
M-8 / 15mm
arruela
dispositivo
p/ lacre
CORTE AA
DETALHE DO
DISPOSITIVO P/LACRE
46
47
Notas:
1 Marca para furao: Duas estampas, uma com 2,6cm circundada por outra de 4,6cm de dimetro para
passagem dos eletrodutos. Para o eletroduto de aterramento uma estampa com 2,2cm de dimetro.
2 A caixa fabricada em chapa de metal deve possuir terminal para aterramento.
3 Medidas em centmetros.
48
Vidro
Fechadura ou trinco a
opo do interessado
CAIXA EXTERNA CE
Fechadura ou trinco a
opo do interessado
Vidro
Notas:
1 Marca para furao: Duas estampas, uma com 2,6cm circundada por outra de 4,6cm de dimetro para
passagem dos eletrodutos. Para o eletroduto de aterramento uma estampa com 2,2cm de dimetro.
2 A caixa fabricada em chapa de metal deve possuir terminal para aterramento.
3 Medidas em centmetros.
10
10
CAIXA INTERNA - CI
10
20
30
40
Vidro
60
10
60
20
Massa para
Vedao
60
2
24
CAIXA EXTERNA
CE
CAIXA EXTERNA
- CE -2
Proteo de metal
no ferroso
66
23
10
10
40
10
20
30
10
Vidro
64
20
Massa para
Vedao
2
60
Nota:
Medidas em centmetros.
2
24
49
ver detalhe
1
fixao do vidro
e vedao
dobradia
vidro 4mm
parafuso
fixo
M - 8 / 15 mm
fechadura ou trinco
marca p/
furao
parafuso p/fixao
da moldura
CORTE BB
CORTE CC
parafuso fixo
M-8 / 15mm
dispositivo p/ lacre
arruela
marca p/ furao
DETALHE
1
DETALHE 2
ver detalhe 2
MOLDURA
CORTE DD
50
VISTA ABERTA
PORTA DE CORRER
51
DETALHE 1
52
Ver detalhe 1
Ver detalhe 1
30x50x1,4
20x50x1,4
DETALHE 2
Notas:
1 Marca para furao: Duas estampas, uma com 2,6cm circundada por outra de 4,6cm de dimetro para
passagem dos eletrodutos. Para o eletroduto de aterramento uma estampa com 2,2cm de dimetro.
2 A caixa fabricada em chapa de metal deve possuir terminal para aterramento.
3 Medidas em centmetros.
VISTA FECHADA
furo p/ o suporte
da caixa 8mm
30x50x1,4
20x50x1,4
furo p/ o suporte
da caixa 8mm
53
VISTA FRONTAL
fixao do vidro
e vedao
dobradia
vidro 4mm
marca p/
furao
parafuso
fixo
M - 8 / 15 mm
A
marca p/
furao
fechadura ou trinco
CORTE CC
CORTE BB
marca p/ furao
furao p/ aterramento
parafuso fixo
M-8 / 15mm
arruela
dispositivo
p/ lacre
CORTE AA
DETALHE DO
DISPOSITIVO P/LACRE
54
55
Notas:
1 Marca para furao: Duas estampas, uma com 2,6cm circundada por outra de 4,6cm de dimetro para
passagem dos eletrodutos. Para o eletroduto de aterramento uma estampa com 2,2cm de dimetro.
2 A caixa fabricada em chapa de metal deve possuir terminal para aterramento.
3 Medidas em centmetros.
56
Vidro
Fechadura ou trinco a
opo do interessado
CAIXA EXTERNA CE
Fechadura ou trinco a
opo do interessado
Vidro
Notas:
1 Marca para furao: Duas estampas, uma com 2,6cm circundada por outra de 4,6cm de dimetro para
passagem dos eletrodutos. Para o eletroduto de aterramento uma estampa com 2,2cm de dimetro.
2 A caixa fabricada em chapa de metal deve possuir terminal para aterramento.
3 Medidas em centmetros.
57
10
10
CAIXA INTERNA - CI
10
20
30
60
Vidro
60
10
60
20
Massa para
Vedao
80
2
24
CAIXA EXTERNA CE
Proteo de metal
no ferroso
66
23
10
10
60
10
20
30
10
Vidro
64
20
Massa para
Vedao
2
80
2
24
Notas:
1 Marca para furao: Duas estampas, uma com 2,6cm circundada por outra de 4,6cm de dimetro para
passagem dos eletrodutos. Para o eletroduto de aterramento uma estampa com 2,2cm de dimetro.
2 A caixa fabricada em chapa de metal deve possuir terminal para aterramento.
3 Medidas em centmetros.
58
3
8
12
20
44
Vidro
40
40
12
CAIXA INTERNA - CI
15
3
60
CAIXA EXTERNA CE
62
8
12
8
20
44
Vidro
38
40
12
20
60
15
Notas:
1 Marca para furao: Duas estampas, uma com 2,6cm circundada por outra de 4,6cm de dimetro para
passagem dos eletrodutos. Para o eletroduto de aterramento uma estampa com 2,2cm de dimetro.
2 A caixa fabricada em chapa de metal deve possuir terminal para aterramento.
3 Medidas em centmetros.
CAIXA INTERNA CI
12
8
20
44
Vidro
40
40
12
Massa para
Vedao
60
2
15
CAIXA EXTERNA CE
Proteo de metal
no ferroso
66
23
44
12
8
20
Vidro
40
12
Massa para
Vedao
2
60
Nota:
Medidas em centmetros.
2
15
59
60
8
12
V idro
80
12
V idro
18
3
18
12
80
30
44
30
12
CAIXA INTERNA - CI
17
3
60
CAIXA EXTERNA CE
62
12
12
30
V idro
18
12
78
78
80
12
18
60
V idro
44
30
20
17
Notas:
1 Marca para furao: Duas estampas, uma com 2,6cm circundada por outra de 4,6cm de dimetro para
passagem dos eletrodutos. Para o eletroduto de aterramento uma estampa com 2,2cm de dimetro.
2 A caixa fabricada em chapa de metal deve possuir terminal para aterramento.
3 Medidas em centmetros.
CAIXA INTERNA - CI
V idro
12
12
M assa p ara
V eda o
30
80
80
30
44
12
18
V idro
18
12
M assa p ara
V eda o
60
15
CAIXA EXTERNA CE
P rote o d e m etal
n o ferroso
66
23
V id ro
80
30
44
30
12
12
M as sa p ara
V eda o
12
V id ro
18
18
12
M as sa p ara
V eda o
2
60
Nota:
Medidas em centmetros.
2
15
61
62
3
10
10
10
CAIXA INTERNA - CI
10
10
55
20
10
100
130
55
130
10
20
20
Vidro
26
150
CAIXA EXTERNA CE
152
10
10
10
29
10
10
55
20
10
128
128
55
130
10
20
20
Vidro
150
26
Notas:
1 Marca para furao: Duas estampas, uma com 2,6cm circundada por outra de 4,6cm de dimetro para
passagem dos eletrodutos. Para o eletroduto de aterramento uma estampa com 2,2cm de dimetro.
2 A caixa fabricada em chapa de metal deve possuir terminal para aterramento.
3 Medidas em centmetros.
63
10
10
10
CAIXA INTERNA CI
Massa para
Vedao
10
10
55
20
10
130
55
130
10
20
20
Vidro
150
24
CAIXA EXTERNA CE
Proteo de metal
no ferroso
156
1
32
10
10
10
Massa para
Vedao
55
10
10
55
20
10
130
10
20
20
Vidro
Nota:
Medidas em centmetros.
150
24
POTNCIA(W)
200
1.500
1.000
5.000
900
450
900
1.200
300
350
1.600
5.000
350
300
750
1.500
5.000
1.300
150
120
140
1.200
1.200
50
400
400
2.700
1.500
2.200
2.960
3.700
5.550
200
350
1.300
3.500
200
3.500
100
Nota:
Na falta das potncias nominais de placa dos aparelhos, estes devem ser os valores mnimos a considerar.
POTNCIA
VA
1.100
1.550
1.650
1.900
2.100
2.860
3.080
4.000
CORRENTE
A
5
7
7,5
8,5
9,5
13
14
18
64
65
DESCRIO
Bancos
CARGAM
NIMA
2
(W/m )
50
FATOR DE DEMANDA%
86
Clubes e semelhantes
20
86
Igrejas e semelhantes
15
86
Lojas e semelhantes
30
86
Restaurantes e semelhantes
20
86
15
86
30
86
86
Oficinas
30
Posto de abastecimento
20
Escolas e semelhantes
30
Escritrios e salas
50
Hospitais e semelhantes
20
Hotis e semelhantes
20
Residncias
30
Notas:
1
2
3
4
Instalaes em que, por sua natureza, a carga seja utilizada simultaneamente, devem ser consideradas com o
fator de demanda de 100%;
Os letreiros luminosos e a iluminao de vitrinas no esto considerados nesta tabela;
O valor da carga para iluminao e tomadas de unidades residenciais, alm de satisfazer a condio mnima
2
de 30W/m de rea construda, nunca deve ser inferior a 2,2kW por unidade.
Para fins de calculo de demanda do item 7.2.1 utilizar fator de potncia=1.
66
FATOR DE DEMANDA
(%)
100
85
80
75
70
65
60
FATOR DE DEMANDA
(%)
100
90
80
70
Nota:
Quando se tratar de unidade central, deve ser considerado um fator igual a 100% e a demanda em kVA,
determinada atravs dos dados fornecidos pelo fabricante.
CARGA (kVA)
POTNCIA (cv)
CARGA (kVA)
1/6
0,45
5
5,40
1/4
0,63
7
7,40
1/3
0,76
10
9,20
1/2
1,01
15
12,70
1,24
20
16,40
1
1,43
25
20,30
1
2,00
30
24,00
2
2,60
40
30,60
3
3,80
50
40,80
Fatores de demanda
NMERO TOTAL DE MOTORES
FATOR DE DEMANDA (%)
1
100
2
90
3a5
80
Mais de 5
70
Nota:
A demanda de um conjunto de motores o produto do somatrio das cargas individuais pelo fator de demanda
correspondente ao nmero total de motores.
67
POTNCIA
1 Maior
2 Maior
3 Maior
Soma dos demais
Maior
Soma dos demais
Maior
Soma dos demais
Solda a arco
e
galvanizao
Solda
a resistncia
Raios-X
Nota:
Mquinas de solda tipo motor-gerador devem ser consideradas como motores.
10
11
12
13
100
75
70
66
62
59
56
53
51
49
47
45
43
14
15
16
17
18
19
20
21
22
23
24
25
ou mais
41
40
39
38
37
36
35
34
33
32
31
30
Nota:
Para o dimensionamento de ramais de entrada destinados a atender a mais de uma unidade consumidora, devem
ser aplicados fatores de demanda para cada tipo de aparelho, separadamente, sendo a demanda total de
aquecimento o somatrio das demandas obtidas:
b = chuveiros + aquecedores + torneiras +...
68
D < 75
220
C18
A3
26 < D < 32
32 < D < 46
46 < D < 66
66 < D < 75
__
D < 11
ALUMNIO
10
D-10
10
T-10
10
Q-10
10
Q-10
10
Q-10
10
Q-16
16
Q-25
25
Q-35
RAMAL ENTRADA
SUBTERRNEO
Ver nota 9
PVC
AO
FN
FF
FFF
FN
FF
8,8
6,5
8,0
8,8
13
10
10
6
10
10
25
35
50
70
95
120
10
10
6
10
10
10
10
16
25
25
35
10
10
6
10
10
16
16
25
35
50
70
20
20
20
25
25
32
32
40
50
50
65
25
25
25
32
32
40
40
50
60
60
75
20
20
20
20
20
20
20
25
25
32
40
1
2
1
1
2
2
3
5
7,5
7,5
7,5
3
2
2
3
5
7,5
7,5
10
12
15
3
5
15
20
25
30
30
30
30
5,4
5,4
3,5
4,6
5,4
7,5
40
50
30
40
10
10
10
10
D-10
T-10
Q-10
Q-10
6
10
6
10
6
10
6
10
6
10
6
10
20
20
20
25
25
25
25
32
20
20
20
20
3
3
2
3
5
3
5
15
20
8,0
8,8
6,5
8,0
50
70
100
10
10
16
Q-10
Q-16
Q-25
10
25
35
10
10
10
10
16
16
25
32
32
32
40
40
20
20
20
3
5
7,5
5
10
12
25
30
40
8,8
125
25
Q-35
50
16
25
40
50
25
7,5
12
50
50
10
D-10
10
10
10
20
25
20
7,5
100
125
150
175
200
225
250
300
C16
C17
C18
C19
32 < D <
46 < D <
66 < D <
82 < D <
46
66
82
99
70
100
125
150
175
COBRE ALUMNIO
16
25
Q-25
Q-35
RAMAL ENTRADA
SUBTERRNEO
Ver nota 9
10
Q-16
16
Q-25
25
Q-35
RAMAL ENTRADA
SUBTERRNEO
Ver nota 9
PROTEO
RAMAL DE
ENTRADA
COBRE ISOLADO
RAMAL DE
ENTRADA
AO
PVC
27 < D < 38
38 < D < 47
47 < D < 57
57 < D < 66
66 < D < 76
76 < D < 86
86 < D < 95
95 < D < 115
RAMAL DE LIGAO
ELETRODUTO DN (mm)
ATERRAMENTO
/PROTEO
TIPO
DISJUNTOR
TERMOMAGNTICO (A)
TENSO
(V)
C5
C6
C7
C8
C9
C10
C11
C12
380/220
220/127
DEMANDA
CALCULADA
D (KVA)
CONDUTOR (mm)
ATERRAMENTO
FORNECIMENTO
CARGA INDIVIDUAL
RESISTIVA
(KW)
ATERRAMENTO
PROTEO
RAMAL DE ENTRADA
PROTEO
COBRE ISOLADO
MAIOR MOTOR OU
SOLDA A MOTOR (CV)
LIMITADA PELO
DISJUNTOR
COBRE
ATERRAMENTO
RAMAL DE ENTRADA
TIPO DE MEDIO
DIRETA
INDIRETA
RAMAL DE LIGAO
35
50
70
95
120
150
185
240
10
16
25
25
35
50
50
70
16
25
35
50
70
70
95
120
32
40
50
50
65
100
100
100
40
50
60
60
75
100
100
100
20
25
25
32
40
40
40
50
19,0 x 1,59
12,0 x 3,18
25,4 x 1,59
19,0 x 3,18
25,4 x 3,18
38,1 x 3,18
38,1 x 3,18
38,1 x 3,18
25
35
50
70
10
10
16
25
16
16
25
35
32
32
40
50
40
40
50
60
20
20
25
25
12,7 x 1,59
12,0 x 3,18
25,4 x 1,59
19,0 x 3,18
95
35
50
65
75
32
19,0 x 3,18
LIMITADA PELO
DISJUNTOR
C15
C16
C17
D < 19
19 < D < 26
50
50
30
40
50
70
100
125
150
175
200
DIRETA
C < 15
10 < 25
D < 10
10 < D < 15
15 < D < 19
19 < D < 27
27 < D < 38
38 < D < 47
47 < D < 57
57 < D < 66
66 < D < 75
DIR. IND.
A2
B2
C13
C14
C < 75
DEMANDA CALCULADA
D (KVA)
TIPO
220/127
FORNECIMENTO
TENSO (V)
C < 10
10 < C 15
380/220
A1
B1
C1
C2
C3
C4
C5
C6
C7
C8
C9
ELETRODUTO DN
(mm)
CONDUTOR (mm)
PROTEO
69
Notas:
1 O valor de "D (kVA)" refere-se demanda calculada conforme o item 7.2.
2 Os disjuntores foram dimensionados com base na sua capacidade nominal definida para a temperatura de
operao de 40C.
3 Para determinar o tipo de disjuntor a ser empregado, consultar o item 10.
4 Os condutores foram dimensionados para uma temperatura ambiente de 30C.
5 A especificao dos condutores para cada finalidade, consta nos itens 8.1.3 e 8.2.2..
6 Nos fornecimentos do tipo A1; B1; C1; C2; C3; A2; B2; C13; C14; C15, quando o eletroduto do ramal de
entrada for embutido deve ser utilizado um dimetro imediatamente superior ao indicado neste Anexo.
7 As dimenses dos eletrodutos de ao referem-se ao tipo leve I (NBR 5624).
8 A potncia mxima para motor ou solda a motor, dentro de cada categoria, foi determinada em funo da
sobrecorrente que o disjuntor pode suportar no tempo requerido para a partida do motor.
9 Nos casos em que a rede de distribuio situa-se no lado oposto da via pblica, os critrios para atendimento
de unidades consumidoras so: Para fornecimentos do tipo C7, C8, C9, C10, C11, C12, C19 e C20, deve ser
previsto extenso da rede de distribuio area, exceto na rea de concesso da CEEE-D, onde aceito
ramal de ligao areo 35mm em cobre ou Q-50mm em alumnio para fornecimento tipo C7 e C19.
10 Recomenda-se para o fornecimento tipo A3 a utilizao de disjuntor com curva classe C.
11 Motores individuais com potncia de 5 ou 7,5 CV, no fornecimento A3, devem ser dotados de dispositivo para
partida indireta.
12 Para a ligao de motores no fornecimento tipo A3, a queda de tenso mxima admitida de 2%, desde o
transformador at o ponto de entrega.
13 As cargas resistivas individuais demonstradas na coluna limite mximo de potncia referem-se a
equipamentos de aquecimento, exemplo chuveiro, boiler, torneira eltrica, etc.
70
POSTE
CONCRETO
ARMADO
EUCALIPTO
(cerne ou tratado)
TUBO DE
AO
(zincado)
SINGELO
(cobre)
CARGA
NOMINAL
(daN)
QUADRADO CIRCULAR
(cm x cm)
(cm)
EXT. x
ESPESS.
(mm x mm)
2 x 10
80
CONDUTOR
(mm)
MULTIPLEX(alumnio)
D-10
T-10
T-16
Q-10
Q-16
Q-25
Q-35
Q-50
---D - Duplex
PONTALETE
ELETRODUTO
DE AO
(zincado
pesado)
DIMETRO
NOMINAL
(mm)
76 x 4,5
12 x 12
25
15
102 x 5,0
3 x 10
4 x 10
100
4 x 16
200
50
18 x 18
22
4 x 25
300
4 x 35
T - Triplex
Q - Quadruplex
Comprimento e engastamento
RAMAL DE LIGAO
POSTE
COMPRIMENTO/ENGASTAMENTO (m)
CONDUTOR
MULTIPLEX
SINGELO
7,0 / 1,30
7,5/1,35
Ramal de Ligao
Altura do poste
Esforo mnimo
Duplex - 10 mm2
5m/7m
60 daN
Triplex 10 mm2
5m/7m
80 daN
Quadruplex 10 mm2
5m/7m
80 daN
Notas:
1 Para carga nominal de 300daN, concretar a base.
2 1daN = 1kgf.
3 Outras alturas e disposies podem ser utilizadas, dependendo da topografia do terreno, a fim de que sejam
obtidas as alturas mnimas entre o condutor inferior e o solo, conforme o item 8.1.1.g e figura 2. Neste caso a
parte engastada deve ser obtida atravs da seguinte expresso:
e = L/10 + 0,6
sendo:
e = parte engastada
L = comprimento total
71
Serie
Paralelo
Compensadora
Resistncias ou
Reatncias
de Partida
Estrela
Tringulo
Srie
Paralelo
Compensadora
TENSO
DE
PLACA
(V)
3 Y
380
3 Y
380/220
5 < P 15
7,5 < P 25
5 < P 25
220/127
380/220
220/127
380/220
660/380
220/380/440/760
380/220
220/380/440/760
220/127
380/220
7,5 < P 25
5 < P 25
7,5 < P 25
380/220
NMERO
DE
TERMINAIS
380/220
220
380/220
7,5
GAIOLA
INDIRETA MANUAL
TENSO
DA
REDE
(V)
220/127
Estrela
Tringulo
INDIRETA
AUTOMTICA
ROTOR
CHAVE
INDUO
DIRETA
PARTIDA
POTNCIA
P (cv)
TIPO
220/380/440/760
6
ou 3
6
ou
ou
TAPs
DE
PARTIDA
50,65 e
80
50
6 Y
6
6 Y
6
12 //
12 s
9Ys 9 Y//
ou
12 Ys12 Y//
6 Y
TAPs
12 // ou 12 Y//
Igual a chave srie-paralelo desde que os valores em ohms das resistncias ou reatncias
sejam iguais ou maiores que o valor obtido da relao 60 cv (220/127) e 180 cv (380/220)
5 < P 15
7,5 < P 25
5 < P 30
7,5 < P 50
5 < P 30
7,5 < P 50
OUTROS DISPOSITIVOS
Admite-se a utilizao de outros dispositivos de reduo da corrente de partida dos motores, tais como: Inversor
de frequncia, Chaves esttica de partida e parada de motores (soft-starters).
72
A tabela abaixo apresenta a capacidade de conduo da corrente em barramentos de cobre sem pintura.
Dimenso
Polegada
1/2 x 1/16
3/4 x 1/16
1 x 1/16
1/2 x 1/8
3/4 x 1/8
1 x 1/8
1 1/2 x 1/8
1 x 3/16
1 1/2 x 3/16
2 x 3/16
1 x 1/4
1 1/2 x 1/4
2 x 1/4
2 1/2 x 1/4
2 3/4 x 1/4
3 1/2 x 1/4
4 x 1/4
1 x 1/2
2 x 1/2
3 x 1/2
4 x 1/2
Corrente
Resistncia
Reatncia
A
96
128
176
144
208
250
370
340
460
595
400
544
700
850
1000
1130
1250
600
1010
1425
1810
m/m
0,8843
0,8591
0,4421
0,4421
0,2955
0,2210
0,1474
0,1474
0,0982
0,0736
0,1110
0,0738
0,0553
0,0442
0,0400
0,0316
0,0276
0,0553
0,0276
0,0184
0,0138
m/m
0,2430
0,2300
0,2280
0,2430
0,2330
0,2070
0,1880
0,2100
0,1880
0,1700
0,2100
0,1870
0,1670
0,1550
0,1510
0,1450
0,1320
0,1870
0,1630
0,1450
0,1300
Milmetro
12,7 x 1,59
19,0 x 1,59
25,4 x 1,59
12,7 x 3,18
19,0 x 3,18
25,4 x 3,18
38,1 x 3,18
25,4 x 4,77
38,1 x 4,77
50,8 x 4,77
25,4 x 6,35
38,1 x 6,35
50,8 x 6,35
63,5 x 6,35
70,2 x 6,35
88,9 x 6,35
101,6 x 6,35
25,4 x 12,70
50,8 x 12,70
76,2 x 12,70
101,6 x 12,77
Nota:
As dimenses em polegadas so para referncias comerciais.
A tabela abaixo apresenta a capacidade de conduo da corrente em condutores de cobre isolados instalados em
eletrodutos.
Seo
Nominal
(mm)
70 C
EPR XLPE 90 C
PVC
70 C
EPR XLPE 90 C
13,5
17,5
24
32
41
57
76
101
125
151
192
232
269
307
353
415
477
12
15,5
21
28
36
50
68
89
111
134
171
207
239
275
314
370
426
18
23
31
42
54
75
100
133
164
198
253
306
354
407
464
546
628
16
20
28
37
48
66
88
117
144
175
222
269
312
358
408
481
553
18
22
29
38
47
63
81
104
125
148
183
216
246
278
312
361
408
15
18
24
31
39
52
67
86
103
122
151
179
203
230
258
297
336
21
26
34
44
56
73
95
121
146
173
213
252
287
324
363
419
474
17,5
22
29
37
46
61
79
101
122
144
178
211
240
271
304
351
396
Formas de Instalaes:
(B1) Instalaes Montagens aparentes, embutidos (gesso, alvenaria, parede de cimento) ou em canaletas
(abertas ou ventiladas).
(D) Enterrado no solo.
Temperatura ambiente: 30 C para linhas no subterrneas e 20 C (temperatura do solo) para linhas
subterrneas. Isolao 0,6/1kV.
Para outras formas de instalao consultar NBR 5410.
73
Referncia
de
Rosca
3/8
3/4
1
1 1/4
1
2
2
3
Dimetro
Externo
16,7
21,1
26,2
33,2
42,2
47,8
59,4
75,1
88,0
CLASSE A
Espessura Dimetro
da Parede Interno
2,0
12,7
2,5
16,1
2,6
21,0
3,2
26,8
3,6
35,0
4,0
39,8
4,6
50,2
5,5
64,1
6,2
75,6
CLASSE B
Espessura
Dimetro
Da Parede
Interno
1,8
13,1
1,8
17,5
2,3
21,6
2,7
27,8
2,9
36,4
3,0
41,8
3,1
53,2
3,8
67,5
4,0
80,0
TOLERNCIA
Dimetro Espessura
Externo da Parede
+0,4
0,3
+ 0,5
0,4
+ 0,6
Notas:
1 O eletroduto deve ser identificado de forma visvel e indelvel contendo, no mnimo: marca do fabricante;
dimetro nominal ou referncia de rosca; classe; os dizeres: eletroduto de PVC rgido.
2 As dimenses em polegadas so para referncias comerciais.
3 Medidas em milmetros.
17,1
21,3
26,7
33,4
42,2
48,3
60,3
73,0
88,9
101,6
114,3
141,3
168,3
0,38
0,64
1,41
1,68
(mm)
2,00
2,25
2,25
2,65
3,00
3,00
3,35
3,75
3,75
4,25
4,25
5,00
5,30
-0,25
-0,28
-0,28
-0,33
-0,37
-0,37
-0,41
-0,46
-0,46
-0,53
-0,53
-0,62
-0,66
13,1
16,8
22,2
28,1
36,2
42,3
53,6
65,5
81,4
93,1
105,8
131,3
157,7
NBR 5598
Espessura
Dimetro
da
Externo
Parede
17,2
21,3
26,9
33,7
42,4
48,3
60,3
76,1
88,9
101,6
114,3
139,7
165,1
0,40
0,42
0,48
0,60
0,76
0,88
1,01
1,14
1,39
1,65
(mm)
2,00
2,25
2,25
2,65
3,00
3,00
3,35
3,75
3,75
4,25
4,25
5,00
5,30
-0,25
-0,28
-0,28
-0,33
-0,37
-0,37
-0,41
-0,41
-0,46
-0,53
-0,53
-0,62
-0,66
T = Tolerncia
Notas:
1 As dimenses em polegadas so para referncias comerciais.
2 Medidas em milmetros.
TIPO LEVE LI
NBR 5624
Espessura
Dimetro
da
Externo
Parede
Dimetro
Interno
3/8
3/4
1
1
1
2
2
3
3
4
5
6
Dimetro
Externo
Dimetro
Interno
10
15
20
25
32
40
50
65
80
90
100
125
150
Referncia
Rosca
Dimetro
Nominal
de
TIPO PESADO
NBR 5597
Espessura
da
Parede
13,2
16,8
22,4
28,4
36,4
42,3
53,6
69,4
81,4
93,1
105,8
129,7
154,5
16,40
20,20
25,40
31,70
40,75
46,85
58,70
74,50
87,20
99,50
112,15
0,10
0,20
0,20
0,20
0,25
0,25
0,30
0,40
0,40
0,50
0,55
(mm)
1,50
-0,18
2,00
2,25
2,25
-0,25
-0,28
-0,28
2,65
-0,33
Dimetro
Interno
13,40
17,20
22,40
28,70
36,75
42,35
54,20
69,20
81,90
94,20
106,85
SEO
NOMINAL
(mm)
1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185
240
16
16
16
16
20
20
25
25
32
40
40
50
50
50
60
16
16
16
20
20
25
32
32
40
40
50
50
60
75
75
4
5
6
7
8
DIMETRO NOMINAL DO ELETRODUTO (mm)
16
16
16
16
20
16
20
20
20
20
20
20
20
25
25
20
25
25
25
25
25
25
32
32
32
25
32
32
40
40
32
40
40
40
50
40
40
50
50
50
40
50
50
60
60
50
50
60
60
75
60
60
75
75
75
60
75
75
75
85
75
75
85
85
75
85
85
85
10
20
25
25
32
40
40
50
50
60
75
85
85
20
25
25
32
40
40
50
60
75
75
85
SEO
NOMINAL
(mm)
1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185
240
10
10
10
10
15
15
20
20
25
32
32
32
40
50
50
10
10
10
15
15
20
25
25
32
32
40
50
50
65
65
4
5
6
7
8
DIMETRO NOMINAL DO ELETRODUTO (mm)
10
10
10
10
15
10
15
15
15
15
15
15
15
20
20
15
20
20
20
20
20
20
25
25
25
20
25
25
32
32
25
32
32
32
40
32
32
32
40
50
32
40
50
50
50
40
50
50
50
65
50
50
65
65
65
50
65
65
65
80
65
65
80
80
90
65
80
80
90
90
80
90
90
100
100
10
15
20
20
25
25
32
40
50
65
65
80
80
90
100
15
20
20
25
32
32
40
50
65
65
80
80
90
100
74
=
=
=
10.000W
10.000W
460W
20.460W
Total
Como 20,46kW>15kW, a demanda deve ser calculada.
Adotada = 20.46kW
75
=
=
=
=
Total
35.000W
20.000W
4.400W
4.600W
64.000W
76
3 Clculo da demanda
3.1 Da iluminao e tomadas: Conforme ANEXO D
a = P x FD x FP
a = 35.000W x 0,86 x 1
a= 30,1kVA
3.2 Dos aparelhos de aquecimento: Conforme ANEXO I
b = P x FD x FP
b = 20.000W x 0,66x 1
b = 13,2kVA
3.3 Dos aparelhos de condicionadores de ar tipo janela: Conforme ANEXO F
c = P x FD
c = 5.000VA x 1
c = 5kVA
3.4 Dos motores: Conforme ANEXO G
e = P x FD
e = 5.400VA x 1
e = 5,4 kVA
3.5Total da loja
D=a+b+c+e
D = 30,1kVA + 13,2kVA + 5kVA+ 5,4kVA
D = 53.7kVA
77
=
=
=
=
Total
81.600W
240.000W
26.400W
21.800W
369.800W
78
1 Cargas instaladas
1.1 Carga instalada por sala:
Iluminao e tomadas
1.000W
4.000W
=
=
=
=
=
8.000W
27.600W
9.200W
1.840W
42.000W
88.640W
=
=
=
27.600W
9.200W
1.840W
38.640W
79
8.000W
38.640W
42.000W
88.640W
3.2Do servio
- Iluminao e tomadas: Conforme ANEXO D
a = P x FD
a = 8.000 x 0,86
a = 6,88kVA
-
80
81
Demanda do servio
D(kVA) = a + d + e
D(kVA) = 6,88+42+30,52
D(kVA) = 79,4kVA
3.3Total da edificao
D= (demanda das unidades consumidoras + demanda do servio)
D = 282,48 + 79,4
D = 361,88kVA
Nota:
Como a demanda calculada foi de 361,88kVA, superior ao limite estabelecido para o fornecimento em BT, aplicar
o que estabelece o RIC/MT.
82
kVA
1,76
1,78
1,80
1,82
1,84
1,86
1,88
1,90
1,92
1,94
1,96
1,98
2,00
2,02
2,04
2,06
2,09
2,10
2,12
2,14
2,15
2,17
2,19
2,21
2,23
2,25
2,27
2,29
2,31
2,33
2,35
2,37
2,39
2,40
2,42
2,44
2,46
2,48
2,50
2,52
rea
til m
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
KVA
2,54
2,56
2,57
2,59
2,61
2,63
2,65
2,67
2,69
2,71
2,73
2,74
2,76
2,78
2,80
2,82
2,84
2,86
2,88
2,89
2,91
2,93
2,95
2,97
2,99
3,01
3,02
3,04
3,06
3,08
3,10
3,12
3,13
3,15
3,17
3,19
3,21
3,23
3,25
3,26
rea
til m
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
kVA
3,28
3,30
3,32
3,34
3,36
3,37
3,39
3,41
3,43
3,45
3,47
3,48
3,50
3,52
3,54
3,56
3,57
3,59
3,61
3,63
3,65
3,67
3,68
3,70
3,72
3,74
3,76
3,77
3,79
3,81
3,83
3,85
3,86
3,88
3,90
3,92
3,94
3,95
3,97
3,99
rea
til m
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
kVA
4,01
4,03
4,04
4,06
4,08
4,10
4,12
4,13
4,15
4,17
4,19
4,20
4,22
4,24
4,26
4,28
4,29
4,31
4,33
4,35
4,36
4,38
4,40
4,42
4,44
4,45
4,47
4,49
4,51
4,52
4,54
4,56
4,58
4,59
4,61
4,63
4,65
4,67
4,68
4,70
rea
til m
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
kVA
4,72
4,74
4,75
4,77
4,79
4,81
4,82
4,84
4,85
4,86
4,89
4,91
4,93
4,95
4,96
4,98
5,00
5,02
5,03
5,05
5,07
5,09
5,10
5,12
5,14
5,16
5,17
5,19
5,21
5,23
5,24
5,26
5,28
5,29
5,31
5,33
5,35
5,36
5,38
5,40
rea
til m
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
kVA
5,42
5,43
5,45
5,47
5,49
5,50
5,52
5,54
5,55
5,57
5,59
5,61
5,62
5,64
5,66
5,68
5,69
5,71
5,73
5,74
5,76
5,78
5,80
5,81
5,83
5,85
5,86
5,88
5,90
5,92
5,93
5,95
5,97
5,98
6,00
6,02
6,04
6,05
6,07
6,09
rea
til m
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
400
450
500
550
600
700
800
900
1000
kVA
6,10
6,12
6,14
6,16
6,17
6,19
6,21
6,22
6,24
6,26
6,27
6,29
6,31
6,33
6,34
6,36
6,38
6,39
6,41
6,43
6,44
6,46
6,48
6,50
6,51
6,53
6,55
6,56
6,58
6,60
6,61
7,45
8,28
9,14
9,91
10,71
12,3
13,86
15,4
16,93
Notas:
1 Para apartamentos com rea intermediria entre as faixas da tabela pode ser aplicado o incremento de
0,02kVA/m sobre a demanda da faixa anterior.
2
2 Para apartamentos com rea inferior a 80m a demanda a ser considerada 1,76kVA.
3 A tabela acima se destina a edificaes de mltiplas unidades consumidoras.
83
N
N
N
N
N
N
N
N
N
Fator
Fator
Fator
Fator
Fator
Fator
Fator
Fator
Fator
Apto.
Apto.
Apto.
Apto.
Apto.
Apto.
Apto.
Apto.
Apto.
-
32
24,69
63
42,62
94
59,98
125
69,59
156
75,49
187
79,54
218
81,74
249
82,69
33
25,29
64
43,18
95
60,54
126
69,79
157
75,64
188
79,64
219
81,79
250
82,72
34
25,90
65
43,74
96
61,1
127
69,99
158
75,79
189
79,74
220
81,84
251
82,73
35
26,50
66
44,30
97
61,66
128
70,19
159
75,94
190
79,84
221
81,89
252
82,74
36
27,10
67
44,86
98
62,22
129
70,39
160
76,09
191
79,94
222
81,94
253
82,75
37
27,71
68
45,42
99
62,78
130
70,59
161
76,24
192
80,04
223
81,99
254
82,76
38
28,31
69
45,98
100
63,34
131
70,79
162
76,39
193
80,14
224
82,04
255
82,77
39
28,92
70
46,54
101
63,59
132
70,99
163
76,54
194
80,24
225
82,09
256
82,78
40
29,52
71
47,10
102
63,84
133
71,19
164
76,69
195
80,34
226
82,12
257
82,79
At 10
9,64
41
30,12
72
47,66
103
64,09
134
71,39
165
76,84
196
80,44
227
82,14
258
82,80
11
10,42
42
30,73
73
48,22
104
64,34
135
71,59
166
76,99
197
80,54
228
82,17
259
82,81
12
11,20
43
31,33
74
48,78
105
64,59
136
71,79
167
77,14
198
80,64
229
82,19
260
82,82
13
11,98
44
31,94
75
49,34
106
64,84
137
71,99
168
77,29
199
80,74
230
82,22
261
82,83
14
12,76
45
32,54
76
49,90
107
65,09
138
72,19
169
77,44
200
80,84
231
82,24
262
82,84
15
13,54
46
33,10
77
50,46
108
65,34
139
72,39
170
77,59
201
80,89
232
82,27
263
82,85
16
14,32
47
33,66
78
51,02
109
65,59
140
72,59
171
77,74
202
80,94
233
82,29
264
82,86
17
15,10
48
34,22
79
51,58
110
65,84
141
72,79
172
77,89
203
80,99
234
82,32
265
82,87
18
15,88
49
34,78
80
52,14
111
66,09
142
72,99
173
78,04
204
81,04
235
82,34
266
82,88
19
16,66
50
35,34
81
52,70
112
66,34
143
73,19
174
78,19
205
81,09
236
82,37
267
82,89
20
17,44
51
35,90
82
53,26
113
66,59
144
73,39
175
78,34
206
81,14
237
82,39
268
82,90
21
18,04
52
36,46
83
53,82
114
66,84
145
73,59
176
78,44
207
81,19
238
82,42
269
82,91
22
18,65
53
37,02
84
54,38
115
67,09
146
73,79
177
78,54
208
81,24
239
82,44
270
82,92
23
19,25
54
37,58
85
54,94
116
67,34
147
73,99
178
78,64
209
81,29
240
82,47
271
82,93
24
19,86
55
38,14
86
55,50
117
67,59
148
74,19
179
78,74
210
81,34
241
82,49
272
82,94
25
20,46
56
38,70
87
56,06
118
67,84
149
74,39
180
78,84
211
81,39
242
82,52
273
82,95
26
21,06
57
39,26
88
56,62
119
68,09
150
74,59
181
78,94
212
81,44
243
82,54
274
82,96
27
21,67
58
39,82
89
57,18
120
68,34
151
74,74
182
79,04
213
81,49
244
82,57
275
82,97
28
22,27
59
40,38
90
57,74
121
68,59
152
74,89
183
79,14
214
81,54
245
82,59
276
83,00
29
22,88
60
40,94
91
58,30
122
68,84
153
75,04
184
79,24
215
81,59
246
82,62
277
83,00
30
23,48
61
41,50
92
58,86
123
69,09
154
75,19
185
79,34
216
81,64
247
82,64
280
83,00
31
24,08
62
42,06
93
59,42
124
69,34
155
75,34
186
79,44
217
81,69
248
82,67
300
83,00
Nota:
Condutores slidos de seo acima de 16mm so para tipos de cabos especiais.
Seo Nominal
mm
0,5
0,75
1
1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
Condutor
compactado
circular
6
6
6
6
6
6
6
6
6
12
15
18
18
30
34
34
53
Condutor
compactado
no circular
6
6
6
12
15
18
18
30
34
34
53
Fios revestidos
/Km
36,0000
24,5000
18,1000
12,1000
7,4100
4,6100
3,8000
1,8300
1,1500
0,7270
0,5240
0,3870
0,2680
0,1930
0,1530
0,1240
0,0991
0,0754
0,0601
0,0470
/Km
36,7000
24,8000
18,2000
12,2000
7,5600
4,7000
3,1100
1,8400
1,1600
0,7340
0,5290
0,3910
0,2700
0,1950
0,1540
0,1260
0,1000
0,0762
0,0607
0,0475
84
85
Dv(%)=
3Il Z
100
Vn
sendo:
DV=queda de tenso em %
Vn= tenso de linha do circuito em Volt
I= corrente da carga, neste caso adotar corrente nominal do disjuntor em Ampre
= comprimento do circuito em km
Z=impedncia do condutor em
Os valores de resistncias eltricas e reatncias indutivas indicados na tabela a seguir so valores mdios e
destinam-se a clculos aproximados de circuitos eltricos, utilizando-se a seguinte frmula:
Z= Rcos + Xsen
ou
Z= R + jX
Z=impedncia do condutor em
R= resistncia do condutor em /km (ver tabela)
X= reatncia do condutor em /km (ver tabela)
= ngulo de fase
Nota:
No caso de utilizao de cabos em paralelo nos circuitos de interligao, a impedncia deve ser dividida pelo
nmeros de circuitos.
86
Resistncia Eltrica e Reatncia Indutiva de Fios e Cabos Isolados em PVC, EPR e XLPE em
Condutos Fechados (Valores em /km)
(B)
Seo
(mm)
1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000
Rcc
(A)
12,1
7,41
4,61
3,08
1,83
1,15
0,73
0,52
0,39
0,27
0,19
0,15
0,12
0,099
0,075
0,060
0,047
0,037
0,028
0,022
0,018
Condutos no-magnticos
Circuitos FN / FF / 3F
(C)
(D)
Rca
XL
14,48
0,16
8,87
0,15
5,52
0,14
3,69
0,13
2,19
0,13
1,38
0,12
0,87
0,12
0,63
0,11
0,47
0,11
0,32
0,10
0,23
0,10
0,19
0,10
0,15
0,10
0,12
0,094
0,094
0,098
0,078
0,097
0,063
0,096
0,052
0,095
0,043
0,093
0,037
0,089
0,033
0,088
87
88
TABELA Y - 1
Dimenses
daN
mm
Seo Circular Seo Quadrada
Base
Topo
Base
Topo
Nominal Ruptura
5,0
1,10
6,0
1,20
7,0
1,30
7,5
1,35
80
100
150
200
80
100
150
200
80
100
150
200
80
100
150
200
160
200
300
400
160
200
300
400
160
200
300
400
160
200
300
400
Conicidade
215
140
180
100
230
140
195
100
mm/m
15
245
140
212
100
282,5
140
220
100
16
Furo para
Ancoragem
(quantidade)
Resistncia
Eletroduto
Embutido (PVC)
Nominal (mm)
Engastamento
Comprimento
Nominal
32
40
60
75
32
40
60
75
32
40
60
75
32
40
60
75
1
1
1
1
2
3
4
4
2
3
4
4
2
3
4
4
ANEXO YA
Placa de identificao
1 NOME OU MARCA
CREA:
DATA DE
F A B R IC A O
C O M P R IM E N T O
N O M IN A L (m )
R E S IS T N C IA
N O M IN A L (d a N )
4
(m n )
Espao 1: para colocao do nome ou marca comercial do fabricante com o nmero do CREA do responsvel
tcnico;
Espao 2:para colocao dos nmeros representativos da data (dia, ms e ano) de fabricao dos postes;
Espao 3:para colocao do nmero representativo do comprimento do poste (5, 6, 7 e 7,5);
Espao 4: para colocao do nmero representativo da resistncia nominal do poste (80, 100, 150, 200 daN).
Notas:
1 As letras e/ou nmero devem ter no mnimo, 4mm de altura por 3mm de largura, gravados de forma legvel e
indelvel;
2 Dimenses em milmetros.
89
ANEXO Z Agrupamentos
Tabela 1 Combinaes Disponibilizadas
N Comb.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
Tipo
2 MONOF
3 MONOF
4 MONOF
5 MONOF
5 MONOF
6 MONOF
7 MONOF
8 MONOF
8 MONOF
2 BIF
3 BIF
3 BIF
4 BIF
4 BIF
5 BIF
5 BIF
2 TRIF
3 TRIF
3 TRIF
4 TRIF
5 TRIF
3 MONOF + 3 BIF
3 MONOF + 3 BIF
3 MONOF + 3 TRIF
3 MONOF + 3 TRIF
Entrada
esquerda
direita
esquerda
direita
esquerda
direita
esquerda
direita
direita
esquerda
direita
esquerda
FIGURAS
CP
Moduladas
FIGURA A FIGURA A1
FIGURA B FIGURA B1
FIGURA B FIGURA C1
FIGURA C FIGURA C1
FIGURA D FIGURA D1
FIGURA E FIGURA E1
FIGURA E FIGURA E1
FIGURA E FIGURA E1
FIGURA F FIGURA F1
FIGURA G FIGURA G1
FIGURA H FIGURA H1
FIGURA I
FIGURA I1
FIGURA J FIGURA J1
FIGURA J FIGURA J1
FIGURA J FIGURA J1
FIGURA J FIGURA J1
FIGURA G FIGURA G1
FIGURA H FIGURA H1
FIGURA I
FIGURA I1
FIGURA J FIGURA J1
FIGURA J FIGURA J1
FIGURA K FIGURA K1
FIGURA L FIGURA L1
FIGURA K FIGURA K1
FIGURA L FIGURA L1
Notas:
1 Estas figuras podem ser utilizadas para maiores combinaes, desde que mantidas as caractersticas e
condies previstas na tabela 2.
2 As CPs e CED podem ser substitudas por caixas de policarbonato modulada.
3 As caixas de medio modelo CPOM devem ser utilizadas para atender as combinaes de agrupamento
previstas neste anexo (moduladas). Este modelo de CM bem como os demais componentes necessrios para
a sua montagem devem ser homologados pelas distribuidoras.
4 A utilizao da CPOM deve ser exclusivamente sobre posta, no sendo permitida a sua utilizao embutida
em alvenaria.
5 O espao entre as caixas de medio moduladas no devem ser preenchidos.
6 Os eletrodutos utilizados para a unio das caixas de medio modelo CPOM devem ser transparentes.
7 As caractersticas de montagem constam nas figuras deste anexo.
8 Em centros de medio no permitido a utilizao simultnea de CPs e CPOMs.
90
ANEXO Z
Tabela 2 LEGENDA
Classe de Tenso
Disjuntor Geral
Ramal de Ligao
220/127 V
380/220 V
Q - 16mm - AL
Q - 10mm - AL
T - 10mm - AL
E
Ramal de Entrada
Circuito de
Distribuio
Circuito Alimentador
Q - 10mm - AL
H
3#10mm - 750V / 32 PVC
PARA RAMAL DE ENTRADA COM TRECHO SUBTERRNEO VIDE NOTA
I
2#10mm - 750V / 20mm PVC
J
K
L
M
Aterramento
Condutor de Proteo
Barra para o
Condutor de Proteo
Barramento Principal
(CED)
1 x (12 x 2) mm - COBRE
4 x (12 x 2) mm - COBRE
Nota:
Ramal de entrada, total ou parcialmente subterrneo, deve ser empregado condutor isolado para 1kV, ao invs de
750V, eletroduto de no mnimo 50mm, conforme item 8.2.3 a.
91
ANEXO Z FIGURA A
AGRUPAMENTO DE 2 MEDIDORES MONOFSICOS
TAMANHO 4
CE
Ramal de ligao D
Ramal de entrada H
Sada
I+P
40
CP-1
CP-1
5
10
60
Condutor de
proteo P
Aterramento O
Notas:
1 Legenda conforme TABELA 2.
2 Cada unidade consumidora deve ser atendida por circuito de distribuio independente e devidamente
identificado, podendo esta identificao ser mediante a utilizao de cores distintas por fase, atravs de
anilhas, fita isolante colorida etc.
3 Medidas em centmetros.
92
ANEXO Z Figura A1
AGRUPAMENTO DE 2 MEDIDORES MONOFSICOS COM CAIXAS MODULADAS
Ramal de ligao
Ramal de entrada
Condutor de
proteo
Aterramento
Vista Superior
Notas:
1 Legenda conforme TABELA 2.
2 Cada unidade consumidora deve ser atendida por circuito de distribuio independente e devidamente
identificado por unidade, podendo esta identificao ser mediante a utilizao de cores distintas por circuito,
anilhas e/ou fita identificao colorida.
3 As caixas de medio modelo CPOM devem ser utilizadas para atender as combinaes de agrupamento
previstas neste anexo (moduladas). Este modelo de CM bem como os demais componentes necessrios para
a sua montagem deve ser liberado pelas distribuidoras.
4 A utilizao da CPOM deve ser exclusivamente sobre posta, no sendo permitida a sua utilizao embutida em
alvenaria.
5 O espao entre as caixas de medio moduladas no devem ser preenchidos.
6 Os eletrodutos utilizados para a unio das caixas de medio CPOM devem ser transparentes.
7 Medidas em centmetros.
93
ANEXO Z Figura B
AGRUPAMENTO DE 4 MEDIDORES MONOFSICOS
Ramal de ligao C
Ramal de entrada F
TAMANHO 5
CE
sada
CP-1
CP-1
1
80
28
CP-1
2
CP-1
3
I+P
10
M
P
Condutor de
proteo P
Aterramento O
60
10
Notas:
1 Legenda conforme TABELA 2.
2 Cada unidade consumidora deve ser atendida por circuito de distribuio independente e devidamente
identificado por unidade, podendo esta identificao ser mediante a utilizao de cores distintas por circuito,
anilhas, fita isolante colorida, etc.
3 Medidas em centmetros.
94
ANEXO Z Figura B1
AGRUPAMENTO DE 3 MEDIDORES MONOFSICOS COM CAIXAS MODULADAS
Ramal de ligao
Ramal de entrada
Ponto para
conexo do
condutor de
proteo
Disj. geral
Condutor de
proteo
Aterramento
Deve ser identificado a primeira CPOM
com n do terreno ou prdio.
As demais devem conter a
numerao 1, 2, 3... etc; na
sequncia lgica, utilizando etiquetas
adesivas com proteo UV na face interna
da tampa, conforme figura.
Vista Superior
Notas:
1 Legenda conforme TABELA 2.
2 Cada unidade consumidora deve ser atendida por circuito de distribuio independente e devidamente
identificado por unidade, podendo esta identificao ser mediante a utilizao de cores distintas por circuito,
anilhas, fita isolante colorida, etc.
3 As caixas de medio modelo CPOM devem ser utilizadas para atender as combinaes de agrupamento
previstas neste anexo (moduladas). Este modelo de CM bem como os demais componentes necessrios para
a sua montagem deve ser liberado pelas distribuidoras.
4 A utilizao da CPOM deve ser exclusivamente sobre posta, no sendo permitida a sua utilizao embutida em
alvenaria.
5 O espao entre as caixas de medio moduladas no devem ser preenchidos.
6 Os eletrodutos utilizados para a unio das caixas de medio CPOM devem ser transparentes.
7 Medidas em centmetros.
95
ANEXO Z Figura C
AGRUPAMENTO DE 5 MEDIDORES MONOFSICOS COM ENTRADA PELA ESQUERDA
barra de
proteo Q
CED - 1
CP-1
CP-1
CP-1
disj. geral A
DPS
CP-1
CP-1
4
I
condutor de
proteo P
aterramento O
PISO
Notas:
1 Legenda conforme TABELA 2.
2 Cada unidade consumidora deve ser atendida por circuito de distribuio independente e devidamente
identificado por unidade, podendo esta identificao ser mediante a utilizao de cores distintas por circuito,
anilhas, fita isolante colorida, etc.
3 Medidas em centmetros.
96
ANEXO Z Figura C1
AGRUPAMENTO DE 5 MEDIDORES MONOFSICOS COM ENTRADA PELA ESQUERDA COM CAIXAS
MODULADAS
Ramal de ligao
Ramal de entrada
Disj. geral
condutor de
proteo
aterramento
Vista Superior
Notas:
1 Legenda conforme TABELA 2.
2 Cada unidade consumidora deve ser atendida por circuito de distribuio independente e devidamente
identificado por unidade, podendo esta identificao ser mediante a utilizao de cores distintas por circuito,
anilhas, fita isolante colorida, etc.
3 As caixas de medio modelo CPOM devem ser utilizadas para atender as combinaes de agrupamento
previstas neste anexo (moduladas). Este modelo de CM bem como os demais componentes necessrios para
a sua montagem deve ser liberado pelas distribuidoras.
4 A utilizao da CPOM deve ser exclusivamente sobre posta, no sendo permitida a sua utilizao embutida em
alvenaria.
5 O espao entre as caixas de medio moduladas no devem ser preenchidos.
6 Os eletrodutos utilizados para a unio das caixas de medio CPOM devem ser transparentes.
7 Medidas em centmetros.
97
ANEXO Z Figura D
AGRUPAMENTO DE 5 MEDIDORES MONOFSICOS COM ENTRADA PELA DIREITA
Ramal de ligao B
Deve ser inscrito na tampa
da primeira CP o n do terreno.
As demais devem conter a
numerao 1, 2, 3... etc; na
sequncia lgica.
Ramal de entrada E
Poste particular
Barra de
proteo Q
CP-1
CP-1
CP-1
P
K
CED - 1
Disj. geral A
M
CP-1
CP-1
4
I
DPS
Condutor de
proteo P
Aterramento O
PISO
Notas:
1 Legenda conforme TABELA 2.
2 Cada unidade consumidora deve ser atendida por circuito de distribuio independente e devidamente
identificado por unidade, podendo esta identificao ser mediante a utilizao de cores distintas por circuito,
anilhas, fita isolante colorida, etc.
3 Medidas em centmetros.
98
ANEXO Z Figura D1
AGRUPAMENTO DE 5 MEDIDORES MONOFSICOS COM ENTRADA PELA DIREITA COM CAIXAS
MODULADAS
Ramal de ligao
Ramal de entrada
Disj. geral
condutor de
proteo
aterramento
Vista Superior
Notas:
1 Legenda conforme TABELA 2.
2 Cada unidade consumidora deve ser atendida por circuito de distribuio independente e devidamente
identificado por unidade, podendo esta identificao ser mediante a utilizao de cores distintas por circuito,
anilhas, fita isolante colorida, etc.
3 As caixas de medio modelo CPOM devem ser utilizadas para atender as combinaes de agrupamento
previstas neste anexo (moduladas). Este modelo de CM bem como os demais componentes necessrios para
a sua montagem deve ser liberado pelas distribuidoras.
4 A utilizao da CPOM deve ser exclusivamente sobre posta, no sendo permitida a sua utilizao embutida em
alvenaria.
5 O espao entre as caixas de medio moduladas no devem ser preenchidos.
6 Os eletrodutos utilizados para a unio das caixas de medio CPOM devem ser transparentes.
7 Medidas em centmetros.
99
ANEXO Z Figura E
AGRUPAMENTO DE 8 MEDIDORES MONOFSICOS COM ENTRADA PELA ESQUERDA
poste particular
ramal de ligao B
ramal de entrada E
barra de
proteo Q
CP-1
CP-1
2
I
J
K
P
CED - 1
CP-1
CP-1
CP-1
CP-1
disj. geral A
M
DPS
J
CP-1
CP-1
7
I
condutor de
proteo P
aterramento O
PISO
Notas:
1 Legenda conforme TABELA 2.
2 Cada unidade consumidora deve ser atendida por circuito de distribuio independente e devidamente
identificado por unidade, podendo esta identificao ser mediante a utilizao de cores distintas por circuito,
anilhas, fita isolante colorida, etc.
3 Medidas em centmetros.
100
ANEXO Z Figura E1
AGRUPAMENTO DE 8 MEDIDORES MONOFSICOS COM ENTRADA PELA ESQUERDACOM CAIXAS
MODULADAS
Ramal de ligao
Ramal de entrada
Disj. geral
condutor de
proteo
aterramento
Vista Superior
Notas:
1 Legenda conforme TABELA 2.
2 Cada unidade consumidora deve ser atendida por circuito de distribuio independente e devidamente
identificado por unidade, podendo esta identificao ser mediante a utilizao de cores distintas por circuito,
anilhas, fita isolante colorida, etc.
3 As caixas de medio modelo CPOM devem ser utilizadas para atender as combinaes de agrupamento
previstas neste anexo (moduladas). Este modelo de CM bem como os demais componentes necessrios para
a sua montagem deve ser liberado pelas distribuidoras.
4 A utilizao da CPOM deve ser exclusivamente sobre posta, no sendo permitida a sua utilizao embutida em
alvenaria.
5 O espao entre as caixas de medio moduladas no devem ser preenchidos.
6 Os eletrodutos utilizados para a unio das caixas de medio CPOM devem ser transparentes.
7 Medidas em centmetros.
101
ANEXO Z Figura F
AGRUPAMENTO DE 8 MEDIDORES MONOFSICOS COM ENTRADA PELA DIREITA
ramal de ligao B
Deve ser inscrito na tampa
da primeira CP o n do terreno.
As demais devem conter a
numerao 1, 2, 3... etc; na
sequncia lgica.
ramal de entrada E
poste particular
barra de
proteo Q
CP-1
CP-1
CP-1
CP-1
CP-1
CP-1
P
K
CED - 1
disj. geral A
M
CP-1
CP-1
7
I
DPS
condutor de
proteo P
aterramento O
PISO
Notas:
1 Legenda conforme TABELA 2.
2 Cada unidade consumidora deve ser atendida por circuito de distribuio independente e devidamente
identificado por unidade, podendo esta identificao ser mediante a utilizao de cores distintas por circuito,
anilhas, fita isolante colorida, etc.
3 Medidas em centmetros.
102
ANEXO Z Figura F1
AGRUPAMENTO DE 8 MEDIDORES MONOFSICOS COM ENTRADA PELA DIREITA COM CAIXAS
MODULADAS
Ramal de ligao
Ramal de entrada
Disj. geral
condutor de
proteo
aterramento
Vista Superior
Notas:
1 Legenda conforme TABELA 2.
2 Cada unidade consumidora deve ser atendida por circuito de distribuio independente e devidamente
identificado por unidade, podendo esta identificao ser mediante a utilizao de cores distintas por circuito,
anilhas, fita isolante colorida, etc.
3 As caixas de medio modelo CPOM devem ser utilizadas para atender as combinaes de agrupamento
previstas neste anexo (moduladas). Este modelo de CM bem como os demais componentes necessrios para
a sua montagem deve ser liberado pelas distribuidoras.
4 A utilizao da CPOM deve ser exclusivamente sobre posta, no sendo permitida a sua utilizao embutida em
alvenaria.
5 O espao entre as caixas de medio moduladas no devem ser preenchidos.
6 Os eletrodutos utilizados para a unio das caixas de medio CPOM devem ser transparentes.
7 Medidas em centmetros.
103
ANEXO Z Figura G
AGRUPAMENTO DE 2 MEDIDORES MONOFSICOS, BIFSICOS OU TRIFSICOS
Circuito Alimentador
Ver nota 6
Poste particular
Disjuntor
ver Nota 4
CP-2
CP-2
N
Q
Condutor de
proteo P
Aterramento O
Ver Nota 5
PISO
Notas:
1 Legenda conforme TABELA 2.
2 Cada unidade consumidora deve ser atendida por circuito de distribuio independente e devidamente
identificado por unidade, podendo esta identificao ser mediante a utilizao de cores distintas por circuito,
anilhas, fita isolante colorida, etc.
3 O ramal de entrada deve ser4#25mm eletroduto 40mm, na tenso de 220/127V e para os tipos de
fornecimentos B2, C14 e C15 na tenso de 380/220V. Para os tipos A2 e C13 o ramal de entrada deve
ser4#16mm eletroduto 32mm na tenso de 380/220V.
4 Os disjuntores individuais ficam limitados em 50A.
5 O circuito de distribuio deve ser da mesma seo do condutor do ramal de entrada.
6 Para dimensionamento dos condutores do circuito alimentador (N) deve ser observada a caracterstica do tipo
de ligao, conforme ANEXO J.
7 Medidas em centmetros.
104
ANEXO Z Figura G1
AGRUPAMENTO DE 2 MEDIDORES MONOFSICOS, BIFSICOS OU TRIFSICOS COM CAIXAS
MODULASDAS
Calha para fixao das caixas e
passagem de cabos para o consumidor.
Ramal de ligao
Ramal de entrada
Ver Nota 2
Circuito Alimentador
Ver nota 5
Disjuntor
ver Nota 3
Condutor de
proteo
Aterramento
Ver Nota 4
Ponto para conexo
do condutor de proteo
Vista Superior
Notas:
1 Legenda conforme TABELA 2.
2 O ramal de entrada deve ser 4#25mm eletroduto 40mm, na tenso de 220/127V e para os tipos de
fornecimentos B2, C14 e C15 na tenso de 380/220V. Para os tipos A2 e C13 o ramal de entrada deve ser
4#16mm eletroduto 32mm na tenso de 380/220V.
3 Os disjuntores individuais ficam limitados em 50A.
4 O circuito de distribuio deve ser da mesma seo do condutor do ramal de entrada.
5 Para dimensionamento dos condutores do circuito alimentador (N) deve ser observada a caracterstica do tipo
de ligao, conforme ANEXO J.
6 Cada unidade consumidora deve ser atendida por circuito de distribuio independente e devidamente
identificado por unidade, podendo esta identificao ser mediante a utilizao de cores distintas por circuito,
anilhas, fita isolante colorida, etc.
7 As caixas de medio modelo CPOM devem ser utilizadas para atender as combinaes de agrupamento
previstas neste anexo (moduladas). Este modelo de CM bem como os demais componentes necessrios para
a sua montagem deve ser liberado pelas distribuidoras.
8 A utilizao da CPOM deve ser exclusivamente sobre posta, no sendo permitida a sua utilizao embutida em
alvenaria.
9 O espao entre as caixas de medio moduladas no devem ser preenchidos.
10 Os eletrodutos utilizados para a unio das caixas de medio CPOM devem ser transparentes.
11 Medidas em centmetros.
105
ANEXO Z Figura H
AGRUPAMENTO DE 3 MEDIDORES COM ENTRADA PELA ESQUERDA
Ramal de ligao B
Ramal de entrada E
Poste particular
Barra de
proteo Q
CP-2
CP-2
N
P
1
K
N
CED - 1
Barramento R
Principal
CP-2
R
DPS
K
Disj. geral A
Condutor de
proteo P
Aterramento O
Notas:
1 Legenda conforme TABELA 2.
2 Cada unidade consumidora deve ser atendida por circuito de distribuio independente e devidamente
identificado por unidade, podendo esta identificao ser mediante a utilizao de cores distintas por circuito,
anilhas, fita isolante colorida, etc.
3 Medidas em centmetros.
106
ANEXO Z Figura H1
AGRUPAMENTO DE 3 MEDIDORES COM ENTRADA PELA ESQUERDA COM CAIXAS MODULADAS
Disj. geral
Condutor de
proteo
Aterramento
Vista Superior
Notas:
1 Legenda conforme TABELA 2.
2 Cada unidade consumidora deve ser atendida por circuito de distribuio independente e devidamente
identificado por unidade, podendo esta identificao ser mediante a utilizao de cores distintas por circuito,
anilhas, fita isolante colorida, etc.
3 As caixas de medio modelo CPOM devem ser utilizadas para atender as combinaes de agrupamento
previstas neste anexo (moduladas). Este modelo de CM bem como os demais componentes necessrios para
a sua montagem deve ser liberado pelas distribuidoras.
4 A utilizao da CPOM deve ser exclusivamente sobre posta, no sendo permitida a sua utilizao embutida em
alvenaria.
5 O espao entre as caixas de medio moduladas no devem ser preenchidos.
6 Os eletrodutos utilizados para a unio das caixas de medio CPOM devem ser transparentes.
7 Medidas em centmetros.
107
ANEXO Z Figura I
AGRUPAMENTO DE 3 MEDIDORES COM ENTRADA PELA DIREITA
D eve ser inscrito na tam pa
da prim eira C P o n do terreno.
A s dem ais devem conter a
num erao 1, 2, 3... etc; na
sequncia lgica.
R am al de ligao B
R am al de entrada E
P oste particular
C P-2
C P -2
K
Barram ento
P rincipal R
C P-2
N
R
D isj. geral A
D PS
CED - 1
C ondutor de
proteo P
A terram ento O
P IS O
Notas:
1 Legenda conforme TABELA 2.
2 Cada unidade consumidora deve ser atendida por circuito de distribuio independente e devidamente
identificado por unidade, podendo esta identificao ser mediante a utilizao de cores distintas por circuito,
anilhas, fita isolante colorida, etc.
3 Medidas em centmetros.
108
ANEXO Z Figura I1
AGRUPAMENTO DE 3 MEDIDORES COM ENTRADA PELA DIREITA COM CAIXAS MODULADAS
Disj. geral
Condutor de
proteo
Aterramento
Deve ser identificado a primeira CPOM
com n do terreno ou prdio.
As demais devem conter a
numerao 1, 2, 3... etc; na
sequncia lgica, utilizando etiquetas
adesivas com proteo UV na face interna
da tampa, conforme figura.
Vista Superior
Notas:
1 Legenda conforme TABELA 2.
2 Cada unidade consumidora deve ser atendida por circuito de distribuio independente e devidamente
identificado por unidade, podendo esta identificao ser mediante a utilizao de cores distintas por circuito,
anilhas, fita isolante colorida, etc.
3 As caixas de medio modelo CPOM devem ser utilizadas para atender as combinaes de agrupamento
previstas neste anexo (moduladas). Este modelo de CM bem como os demais componentes necessrios para
a sua montagem deve ser liberado pelas distribuidoras.
4 A utilizao da CPOM deve ser exclusivamente sobre posta, no sendo permitida a sua utilizao embutida em
alvenaria.
5 O espao entre as caixas de medio moduladas no devem ser preenchidos.
6 Os eletrodutos utilizados para a unio das caixas de medio CPOM devem ser transparentes.
7 Medidas em centmetros.
109
ANEXO Z Figura J
AGRUPAMENTO DE 5 MEDIDORES
Ramal de ligao B
Ramal de entrada E
Poste particular
Barra de
proteo Q
CP-2
1
K
Barramento
Principal R
P
N
CP-2
CP-2
K
L
N
CP-2
CP-2
R
Disj. geral A
DPS
CED - 1
Condutor de
proteo P
Aterramento O
Notas:
1 Legenda conforme TABELA 2.
2 Cada unidade consumidora deve ser atendida por circuito de distribuio independente e devidamente
identificado por unidade, podendo esta identificao ser mediante a utilizao de cores distintas por circuito,
anilhas, fita isolante colorida, etc.
3 Medidas em centmetros.
110
ANEXO Z Figura J1
AGRUPAMENTO DE 5 MEDIDORES COM CAIXAS MODULADAS
Disj. geral
Condutor de
proteo
Aterramento
Vista Superior
Notas:
1 Legenda conforme TABELA 2.
2 Cada unidade consumidora deve ser atendida por circuito de distribuio independente e devidamente
identificado por unidade, podendo esta identificao ser mediante a utilizao de cores distintas por circuito,
anilhas, fita isolante colorida, etc.
3 As caixas de medio modelo CPOM devem ser utilizadas para atender as combinaes de agrupamento
previstas neste anexo (moduladas). Este modelo de CM bem como os demais componentes necessrios para
a sua montagem deve ser liberado pelas distribuidoras.
4 A utilizao da CPOM deve ser exclusivamente sobre posta, no sendo permitida a sua utilizao embutida em
alvenaria.
5 O espao entre as caixas de medio moduladas no devem ser preenchidos.
6 Os eletrodutos utilizados para a unio das caixas de medio CPOM devem ser transparentes.
7 Medidas em centmetros.
111
ANEXO Z Figura K
AGRUPAMENTO DE 6 MEDIDORES COM ENTRADA PELA DIREITA
Ramal de ligao B
Ramal de entrada E
Poste particular
N
CP-2
CP-2
CP-2
N
Barramento
Principal R
1
K
L
Barra de
proteo Q
CP-1
CP-1
I
CP-1
DPS
5
I
Disj. Geral A
CED - 1
Condutor de
proteo P
Aterramento O
Notas:
1 Legenda conforme TABELA2.
2 Cada unidade consumidora deve ser atendida por circuito de distribuio independente e devidamente
identificado por unidade, podendo esta identificao ser mediante a utilizao de cores distintas por circuito,
anilhas, fita isolante colorida, etc.
3 Medidas em centmetros.
112
ANEXO Z Figura K1
AGRUPAMENTO DE 6 MEDIDORES COM ENTRADA PELA DIREITA COM CAIXAS MODULADAS
Ramal de ligao
Ramal de entrada
Disj. geral
Condutor de
proteo
Aterramento
Vista Superior
Notas:
1 Legenda conforme TABELA 2.
2 Cada unidade consumidora deve ser atendida por circuito de distribuio independente e devidamente
identificado por unidade, podendo esta identificao ser mediante a utilizao de cores distintas por circuito,
anilhas, fita isolante colorida, etc.
3 As caixas de medio modelo CPOM devem ser utilizadas para atender as combinaes de agrupamento
previstas neste anexo (moduladas). Este modelo de CM bem como os demais componentes necessrios para
a sua montagem deve ser liberado pelas distribuidoras.
4 A utilizao da CPOM deve ser exclusivamente sobre posta, no sendo permitida a sua utilizao embutida em
alvenaria.
5 O espao entre as caixas de medio moduladas no devem ser preenchidos.
6 Os eletrodutos utilizados para a unio das caixas de medio CPOM devem ser transparentes.
7 Medidas em centmetros.
113
ANEXO Z Figura L
AGRUPAMENTO DE 6 MEDIDORES COM ENTRADA PELA ESQUERDA
Ramal de ligao B
Ramal de entrada E
Poste particular
CP-2
1
K
CP-2
CP-2
N
Barramento
Principal
R
CED - 1
Barra de
proteo Q
CP-1
DPS
J
Disj. geral A
CP-1
CP-1
5
I
condutor de
proteo P
aterramento O
Notas:
1 Legenda conforme TABELA 2.
2 Cada unidade consumidora deve ser atendida por circuito de distribuio independente e devidamente
identificado por unidade, podendo esta identificao ser mediante a utilizao de cores distintas por circuito,
anilhas, fita isolante colorida, etc.
3 Medidas em centmetros.
114
ANEXO Z Figura L1
AGRUPAMENTO DE 6 MEDIDORES COM ENTRADA PELA ESQUERDA COM CAIXAS MODULADAS
Disj. geral
Condutor de
proteo
Aterramento
Vista Superior
Notas:
1 Legenda conforme TABELA 2.
2 Cada unidade consumidora deve ser atendida por circuito de distribuio independente e devidamente
identificado por unidade, podendo esta identificao ser mediante a utilizao de cores distintas por circuito,
anilhas, fita isolante colorida, etc.
3 As caixas de medio modelo CPOM devem ser utilizadas para atender as combinaes de agrupamento
previstas neste anexo (moduladas). Este modelo de CM bem como os demais componentes necessrios para
a sua montagem deve ser liberado pelas distribuidoras.
4 A utilizao da CPOM deve ser exclusivamente sobre posta, no sendo permitida a sua utilizao embutida em
alvenaria.
5 O espao entre as caixas de medio moduladas no devem ser preenchidos.
6 Os eletrodutos utilizados para a unio das caixas de medio CPOM devem ser transparentes.
7 Medidas em centmetros.
FIGURAS
AREA
p o n to d e
e n tre g a
r a m a l d e lig a o
c o n d u to r d o
c ir c u it o a lim e n ta d o r
r e d e s e c u n d r ia
d e d is t r ib u i o
c o n d u to r d o
r a m a l d e e n tr a d a
e le t r o d u t o d o
ra m a l d e e n tra d a
e le tr o d u t o
d o c ir c u it o
a lim e n t a d o r
p o s te p a r t ic u la r
m e d i o
e le t r o d u t o d e
a te r r a m e n t o
h a s te d e
a te rra m e n to
A B - R A M A L D E L IG A O
AC BC BCD
CDE
E N T R A D A D E S E R V I O
RAM AL DE ENTRADA
- E N T R A D A D E E N E R G IA
- C IR C U IT O A L IM E N T A D O R
rede secundria
de distribuio
ponto de entrega
condutor do ramal
de entrada subterrneo
eletroduto de proteo
medio
via pblica
(pista de rolamento)
eletroduto do
ramal de entrada
duto do ramal
de entrada
eletroduto
de proteo
via interna
(rea privada)
medio
eletroduto do
ramal de entrada
duto do ramal
de entrada
116
passeio
pista de rolamento
pista de rolamento
passeio
passeio
117
poste da rede
ramal de ligao
poste
particular
passeio
poste da rede
poste
particular
muro
118
Nota:
As disposies acima tambm se aplicam para entradas subterrneas, observado-se a disposio do ramal de
entrada conforme figura 4.
119
Pista de
Rolamento
calada
calada
alinhamento da rua
mx. 30m
caixa de
passagem
rede secundaria
de distribuio
alinhamento da rua
Nota:
Para a utilizao de ramal subterrneo em travessia de via pblica (pista de rolamento) deve ser consultada a
distribuidora local.
120
MEDIO FRONTAL
MURO OU MURETA
COMPARTILHAMENTO ABERTO
grade ou muro
porto
muro ou
mureta
grade ou muro
mn. 100cm
poste
medio
grade ou muro
mn. 80cm
medio
poste
alinhamento da rua
alinhamento da rua
COMPARTILHAMENTO ABERTO
grade ou muro
mn. 1000mm
mn. 1000mm
muro ou
mureta
poste
medio
alinhamento da rua
medio
poste
grade ou muro
alinhamento da rua
COMPARTILHAMENTO FECHADO
grade ou muro
grade ou muro
grade
alinhamento da rua
muro ou
mureta
medio
grade com
chave padro
poste
alinhamento da rua
mn. 100cm
mn. 100cm
poste
medio
grade ou muro
acesso com
chave padro
Nota:
Nas reas de distribuio da AES Sul e RGE, a medio lateral em lote sem delimitao fsica entre a rea
privada com a via publica, deve ser provida de compartimento edificado.
Recomenda-se a utilizao de
grade com cadeado padro,
observadas as posturas municipais.
CAIXA DE MEDIO
NO MURO LATERAL
PORTO RECUADO
CAIXA DE MEDIO
NO MURO FRONTAL
PORTO DA EDIFICAO
CAVIDADE DE
INSPEO
MURO
FRONTAL
CAVIDADE DE
INSPEO
ALINHAMENTO
DA RUA
MURO
FRONTAL
ALINHAMENTO
DA RUA
CAIXA DE MEDIO NO
MURO LATERAL
COMPARTIMENTO ABERTO
CAIXA DE MEDIO
NO POSTE FRONTAL
CAVIDADE DE
INSPEO
ALINHAMENTO
DA RUA
MURO
FRONTAL
ALINHAMENTO
DA RUA
CAVIDADE DE
INSPEO
CAIXA DE MEDIO NO
POSTE FRONTAL
COMPARTIMENTO FECHADO
CAIXA DE MEDIO NO
MURO LATERAL
COMPARTIMENTO FECHADO
CAVIDADE DE
INSPEO
ALINHAMENTO
DA RUA
MURO
FRONTAL
ALINHAMENTO
DA RUA
CAVIDADE DE
INSPEO
Notas:
1 A altura do compartimento da medio deve estar de acordo com a limitao fsica frontal.
2 Para fixao da caixa de medio em muro frontal ver figura 9B.
121
122
circuito alimentador
10
10
30
condutor singelo
braadeira ou
parafuso passante
30
N
F1
F2
02 curvas 90 ou
01 curva 180
(quando de ao
colocar bucha)
F3
braadeira ou
parafuso passante
poste particular
VISTA LATERAL
eletroduto de ao ou
PVC rgido preto
50 mx.
16015
caixa para
medidor
eletroduto de PVC
rgido preto
cavidade de inspeo
ver figua 38
condutores de
cobre isolado
haste de
aterramento
DETALHE DE ATERRAMENTO
Mn.20x20x20
condutor
proteo
condutor
aterramento
haste de
aterramento
Notas:
1 A disposio dos isoladores deve ser de acordo com a figura 14 e 17.
2 O isolador para a ancoragem do circuito alimentador deve ser fixado a 30cm abaixo do ltimo isolador do ramal
de ligao.
3 Utilizar no mximo trs (03) curvas de 90 no eletroduto de entrada, exceo feita para caixas CPO em uso
externo, quando podem ser usadas duas curvas de 180 ou quatro de 90.
4 Nas reas de distribuio da AES Sul e RGE, a medio lateral em lote sem delimitao fsica entre a rea
privada com a via publica, deve ser provida de compartimento edificado.
5 Medidas em centmetros.
123
15
10
entrada
205
isolador de 2 leitos
neutro
condutor de proteo
10
fase
DETALHE ATERRAMENTO
sada
cavidade inspeo
Mn.20x20x20
condutor
proteo
condutor de
aterramento
haste de
aterramento
DETALHE ENGASTAMENTO
Linha do solo
base concreto
50x50x50
16015
50 mx.
Notas:
1 O eletrodo de aterramento deve ser instalado fora da base concretada.
2 Os condutores de aterramento e proteo devem ser protegidos por eletroduto dentro da base concretada.
3 Nas reas de distribuio da AES Sul e RGE, a medio lateral em lote sem delimitao fsica entre a rea
privada com a via publica, deve ser provida de compartimento edificado.
4 Medidas em centmetros.
124
15
10
entrada
205
neutro
isolador de 2 leitos
condutor de p roteo
205
fase
10
205
fase
sada
D E TAL H E ATE R R AM EN TO
cavidade inspeo
M n.20x20x20
condutor
proteo
condutor de
aterram ento
haste de
aterram ento
D ET ALH E EN G ASTAM EN TO
Linha do solo
base concreto
50x50x50
16015
50 m x.
Notas:
1 O eletrodo de aterramento deve ser instalado fora da base concretada.
2 Os condutores de aterramento e proteo devem ser protegidos por eletroduto dentro da base concretada.
3 Nas reas de distribuio da AES Sul e RGE, a medio lateral em lote sem delimitao fsica entre a rea
privada com a via publica, deve ser provida de compartimento edificado.
4 Medidas em centmetros.
125
mn. 100
COMPARTIMENTO ABERTO
muro ou
mureta
medio
medio
grade
ou muro
mn. 80
mn. 100
grade
ou muro
porto
mn. 100
poste
acesso com
chave padro
alinhamento da rua
VISTA FRONTAL
ramal de
ligao multiplex
DETALHE ATERRAMENTO
cavidade inspeo
Mn.20x20x20
condutor
proteo
poste particular
compartilhado
haste de
aterramento
16015
condutor de
aterramento
Notas:
1 A disposio dos isoladores deve ser de acordo com a figura 14 e 17.
2 Utilizar no mximo trs (03) curvas de 90 no eletroduto de entrada, exceo feita para caixas CPO em uso
externo, quando podem ser usadas duas curvas de 180 ou quatro de 90.
3 Nas reas de distribuio da AES Sul e RGE, a medio lateral em lote sem delimitao fsica entre a rea
privada com a via publica, deve ser provida de compartimento edificado.
4 Medidas em centmetros.
muro ou
mureta
alinhamento da rua
grade
ou muro
medio
poste
VISTA FRONTAL
ramal de
ligao multiplex
DETALHE ATERRAMENTO
cavidade inspeo
Mn.20x20x20
condutor
proteo
poste particular
compartilhado
16015
condutor de
aterramento
Notas:
1 A disposio dos isoladores deve ser de acordo com a figura 14 e 17.
2 Medidas em centmetros.
haste de
aterramento
126
127
Notas:
1 A disposio dos isoladores deve ser de acordo com a figura 14 e 17.
2 Utilizar no mximo trs (03) curvas de 90 no eletroduto de entrada.
3 Nas reas de distribuio da AES Sul e RGE, a medio lateral em lote sem delimitao fsica entre a rea
privada com a via publica, deve ser provida de compartimento edificado.
4 Medidas em centmetros.
128
Notas:
1 A disposio dos isoladores deve ser de acordo com a figura 14 e 17.
2 Utilizar, em uso externo, duas curvas de 180 ou quatro de 90.
3 Nas reas de distribuio da AES Sul e RGE, a medio lateral em lote sem delimitao fsica entre a rea
privada com a via publica, deve ser provida de compartimento edificado.
4 Medidas em centmetros
129
30
10
ramal de
ligao multiplex
10mn.
ramal de ligao
condutor singelo
pingadeira
poste particular
eletroduto de PVC
rgido ou ao
zincado a quente
30
curva 90
quando de ao
colocar bucha
caixa para
medidor
mureta
sada subterrnea
ou embutida
16015
50 mx.
condutores de
cobre isolado
eletroduto de
PVC rgido
cavidade de inspeo
ver figura 38
DETALHE ATERRAMENTO
cavidade inspeo
Mn.20x20x20
condutor
proteo
condutor
aterramento
haste de
aterramento
Notas:
1 A disposio dos isoladores deve ser de acordo com a figura 14 e 17.
2 Utilizar no mximo trs (03) curvas de 90 no eletroduto de entrada.
3 Nas reas de distribuio da AES Sul e RGE, a medio lateral em lote sem delimitao fsica entre a rea
privada com a via publica, deve ser provida de compartimento edificado.
4 Medida em centmetros.
2,5
10
30
ramal de
ligao multiplex
poste particular
curva 90
quando de ao
colocar bucha
eletroduto de PVC
rgido ou ao
zincado a quente
caixa para
medidor
mureta
eletroduto de
PVC rgido
16015
sada subterrnea
ou embutida
cavidade de inspeo
ver figura 38
condutores de
cobre isolado
DETALHE ATERRAMENTO
cavidade inspeo
Mn.20x20x20
condutor
proteo
condutor
aterramento
Notas:
1 A disposio do isolador deve ser de acordo com a figura 14 e 17.
2 Utilizar no mximo trs (03) curvas de 90 no eletroduto de entrada.
3 A medio frontal pode ser no alinhamento da rua ou no mximo a 50 cm.
4 Medidas em centmetros.
haste de
aterramento
130
Recomenda-se a utilizao de
grade com cadeado padro,
observadas as posturas
municipais.
Notas:
1 A disposio do isolador deve ser de acordo com a figura 14 e 17.
2 Utilizar no mximo trs (03) curvas de 90 no eletroduto de entrada.
3 Na medio frontal, pode ser no alinhamento da rua ou no mximo a 50 cm.
4 Medidas em centmetros.
131
132
Notas:
1 A disposio do isolador deve ser de acordo com a figura 14 e 17.
2 Para a utilizao de abertura na grade (tipo janela) para acesso a medio, deve-se observar cdigo de
postura municipal. Quando da utilizao de cadeado (na grade) este deve ser cadeado padro.
3 Esta alternativa pode ser utilizada para qualquer tipo de fornecimento, com qualquer modelo de caixa de
medio externa ou de policarbonato lacrvel e em postes de ao, concreto armado e madeira.
4 Utilizar no mximo trs (03) curvas de 90 no eletroduto de entrada, exceo feita para caixas CPO em uso
externo, quando podem ser usadas duas curvas de 180 ou quatro de 90.
5 Na medio frontal instalada em grade deve ser observada uma distncia mxima de 5 cm entre a CM e o
alinhamento (grade).
6 Medidas em centmetros.
CONDUTOR SINGELO
CONDUTOR MULTIPLEXADO
30
ver nota 1
30
eletroduto de PVC
rgido ou de ao
curva 90
quando de ao
colocar bucha
16015
caixa para
medidor
condutores de
cobre isolado
cavidade de inspeo
ver figura 38
eletroduto de
PVC rgido preto
DETALHE ATERRAMENTO
cavidade inspeo
Mn.20x20x20
condutor
proteo
condutor
aterramento
haste de
aterramento
Notas:
1 A disposio do isolador deve ser de acordo com a figura 14 e 17.
2 Medidas em centmetros.
eletroduto de
PVC rgido
133
134
30
30
ver nota 1
eletroduto de PVC
rgido ou de ao
curva 90
quando de ao
colocar bucha
passeio
via pblica
Vista Superior
Poste
da
rede
mx. 50
mn. 30
Porto
16015
caixa para
medidor
Caixa de medio
eletroduto de
PVC rgido preto
DETALHE ATERRAMENTO
eletroduto de
PVC rgido
cavidade de inspeo
ver figura 38
cavidade inspeo
Mn.20x20x20
condutor
proteo
condutor
aterramento
condutores de
cobre isolado
haste de
aterramento
Notas:
1 A disposio do isolador deve ser de acordo com a figura 14 e 17.
2 Nas reas de distribuio da AES Sul e RGE, a medio lateral em lote sem delimitao fsica entre a rea
privada com a via pblica, deve ser provida de compartimento edificado.
3 Medidas em centmetros.
135
CONDUTOR MULTIPLEXADO
120 mx.
20 mn
30
30
curva 90 de ao
zincado com bucha
ou PVC rgido
mn. 20
mx. 60
fixao junto ao
madeiramento
DETALHE
PONTALETE
eletroduto de
ao zincado
caixa para
medidor
16015
condutores de
cobre isolado
cavidade de inspeo
ver figura 38
eletroduto de
PVC rgido preto
DETALHE ATERRAMENTO
eletroduto de
PVC rgido
cavidade inspeo
Mn.20x20x20
condutor
proteo
condutor
aterramento
haste de
aterramento
Notas:
1 Para a utilizao de pontalete consultar a distribuidora local.
2 A disposio do isolador castanha deve ser de acordo com o detalhe acima e figura 14.
3 Em regies com acentuado ndice de corroso (carbonferas e litorneas) a amarrao do isolador deve ser
feita com a utilizao de fio de cobre 10mm.
4 Poder ser mantido o pontalete de 20mm, somente em caso de reforma da instalao consumidora e que
esteja do mesmo lado da rede da distribuidora.
5 Medidas em centmetros.
136
Neutro
Fase A
Fase B
Fase C
Consumidor
Caixa de
Medio
DETALHE ATERRAMENTO
cavidade inspeo
Mn.20x20x20
condutor
proteo
VISTA FRONTAL
210
condutor de
aterramento
haste de
aterramento
Ver nota 3
Eletroduto
de PVC
Haste de
Aterramento
Notas:
1 Eletrodutos devem ser por baixo da caixa de medio.
2 Tolerncia 210 5cm.
3 O eletroduto do condutor de aterramento e proteo deve possuir no mnimo dois pontos de fixao junto ao
poste
4 Medidas em centmetros.
137
Neutro
Fase A
Fase B
Fase C
Eletroduto
de PVC
VISTA FRONTAL
Caixa de
Medio
DETALHE ATERRAMENTO
cavidade inspeo
Mn.20x20x20
condutor
proteo
haste de
aterramento
210
condutor de
aterramento
Ver nota 3
Eletroduto
de PVC
Haste de
Aterramento
Notas:
1 Eletrodutos devem ser por baixo da caixa de medio.
2 Tolerncia 210 5cm.
3 O eletroduto do condutor de aterramento e proteo deve possuir no mnimo dois pontos de fixao junto ao
poste
4 Medidas em centmetros.
138
Neutro
Fase A
Fase B
Fase C
Eletroduto
de PVC
Caixa de
Medio e
Disjuntor com DR
VISTA FRONTAL
DETALHE ATERRAMENTO
cavidade inspeo
Mn.20x20x20
condutor
proteo
haste de
aterramento
210
condutor de
aterramento
Ver nota 3
Eletroduto
de PVC
Haste de
Aterramento
Notas:
1 Eletrodutos devem ser por baixo da caixa de medio.
2 Tolerncia 210 5cm.
3 O eletroduto do condutor de aterramento e proteo deve possuir no mnimo dois pontos de fixao junto ao
poste
4 Medidas em centmetros.
139
4 condutores
N
20
F1
30
F3
30
30
F2
30
F1
F1
20
F2
20
F1
20
20
2 condutores
Multiplexado
20
3 condutores
PAREDE
20
20
20
20
20
20
F1
F1
F1
F2
F2
F1
F1
F2
F2
F3
F3
2 condutores
Multiplexado
20
20
20
F1
20
20
20
30
F1
3 condutores
4 condutores
PONTALETE
20
F2
F3
LEGENDA
mn. 20
F2
20
F1
20
F1
20
20
mn. 20
F1
30
30
N
20
mn. 20
mn. 20
F1
4 condutores
3 condutores
30
2 condutores
30
Multiplexado
Curva
Isolador
Notas:
1 Para a ancoragem do ramal de ligao em poste, deve ser observado um afastamento de 10 cm entre o topo e
o primeiro isolador.
2 Medidas em centmetro.
140
rede secundria
de distribuio
ponto de entrega
condutor do ramal
de entrada subterrneo
n do prdio
bucha
570cm
eletroduto ao carbono
galvanizado a fogo fixar
em 3 pontos ver - Nota 1
medio
eletroduto do
ramal de entrada
de ao ou PVC
30cm mn.
via pblica
(pista de rolamento)
brita
caixa de passagem
do ramal de entrada
mnimo 50x50x60
declve mnimo 2%
duto de entrada
30cm
aterramento do eletroduto de
ao carbono galvanizado a fogo
caixa de
passagem
curva de raio
longo em PVC
Eletroduto
Notas:
1 O eletroduto junto ao poste deve ser de dimetro nominal de no mnimo 50mm, com altura mnima de 5,70m,
do solo.
2 O eletroduto junto ao poste deve ser identificado com o nmero do prdio a ser ligado, mediante a utilizao de
material no corrosivo, fixado na extremidade superior do mesmo.
141
rede secundria
de distribuio
bucha
aterramento do eletroduto
ponto de
entrega
condutor do ramal
de entrada subterrneo
terminal para cabo multipolar
(copo de bloqueio)
n do prdio
eletroduto do
ramal de entrada
de ao ou PVC
fita de identificao
conforme item 8.2.3 - Nota 2
pista de rolamento
30cm mn.
curva de
raio longo
mnimo 1
volta de cabo
brita
areia
caixa de passagem
do ramal de entrada
mnimo 50x50x60
brita
declve mnimo 2 %
duto de entrada
caixa de
passagem
do ramal de
entrada
duto subterrneo
(ver item 8.2.3.c)
5cm
mnimo
passeio
medio
eletroduto ao carbono
galvanizado a fogo
fixar em 3 pontos
ver nota 1
60cm mn.
270 cm
Envelopamento de concreto
para eletroduto de PVC ou
duto corrugado. Ver 8.2.3-c
aterramento do eletroduto de
ao carbono galvanizado a fogo
caixa de
passagem
curva de raio
longo em PVC
Eletroduto
Notas:
1 O eletroduto junto ao poste deve ser de dimetro nominal de no mnimo 50mm, com altura mnima de 5,70m,
do solo.
2 O eletroduto junto ao poste deve ser identificado com o nmero do prdio a ser ligado, mediante a utilizao de
material no corrosivo, fixado na extremidade superior do mesmo.
3 Medidas em centmetros.
142
120
120
50
120
50
50
120
50
120
Notas:
1 A ancoragem do ramal de ligao na fachada, s permitida fora da rea delimitada, se atender as alturas
mnimas dos condutores ao solo.
2 Medida em centmetros.
143
cinta
armao com
um estribo
cinta
haste
armao com
dois estribos
isolador roldana
76x80mm
parafuso passante
16mm usado
tambm em parede
PONTALETE
chumbador ou
parafuso passante
mnimo 3 voltas com
arame de ao 12BWG
Notas:
1 Em regies com acentuado ndice de corroso (carbonferas e litorneas) a amarrao do isolador no pontalete
deve ser feita com a utilizao de fio de cobre 10mm.
2 Em parede de madeira usar parafuso passante para fixao da armao secundria.
3 Os isoladores devem ser confeccionados conforme NBR 6248 e NBR 6249.
POSTE DE CONCRETO
(sem furao)
POSTE DE AO
6m m
16m m
parafuso
cabea
abaulada
6m m
braadeira
cinta
suporte
suporte
POSTE DE M ADEIRA
(com furao)
travessa de
m adeira 4x5cm
afastador
(isolador roldana 42x42 ou 48x48mm).
Dispensvel em caixas de fibra.
6mm
suporte
6m m
16mm
parafuso
passante
16mm
parafuso
passante
Nota:
1 A fixao da caixa modelo CPO deve obedecer especificao do fabricante.
144
parafuso passante
6mm
6mm
6mm
parafuso
passante
travessa
metlica
16mm
suporte
suporte
PAREDE DE ALVENARIA
(com eletrodutos embutidos)
PAREDE DE MADEIRA
suporte
FIXAO
PAREDE
MADEIRA
PARAF. DE 6mm
ROSCA SOBERBA
PASSANTE
Nota:
1 A fixao da caixa modelo CPO deve obedecer especificao do fabricante.
145
146
PAREDE
ALVENARIA
(com eletroduto embutido)
ALVENARIA
parafuso passante
16mm
ou chumbador
afastador
(isolador roldana 76x80mm)
parafuso passante
de 16mm
parafuso passante
6mm
ou com bucha
parafuso passante
6mm
suporte
caixa tamanho 6 ou 7
caixa tamanho 6 ou 7
POSTE
parafuso passante
16mm
afastador
(isolador roldana 76x80mm)
caixa tamanho 6 ou 7
parafuso passante
6mm
caixa tamanho 6 ou 7
suporte
parafuso
cabea
abaulada
16mm
6mm
cinta
suporte
POSTE DE MADEIRA
(com furao)
parafuso
passante
6mm
travessa de
madeira 4x5cm
parafuso
passante
16mm
suporte
Nota:
1 A fixao da caixa modelo CPO deve obedecer especificao do fabricante.
parafuso
passante
16mm
147
148
sada
entrada
aterramento
aterramento
sada
DETALHE
arruela
ver detalhe
entrada
aterramento
entrada
bucha
eletroduto
entrada
aterramento
Notas:
1 Os orifcios no utilizados devem ser vedados.
2 As junes entre os eletrodutos e as caixas, quando ao tempo, devem ser vedadas com massa de calafetar.
3 A entrada pode ser por baixo, quando for ramal de entrada subterrneo.
4 A entrada e sada da caixa modelo CPO, quando instalada ao tempo deve ser por baixo ou, quando embutida,
por trs ou pela lateral.
149
Notas:
1 A disposio dos eletrodutos de entrada e sada para caixas internas (CI) deve ser de acordo com a figura 22.
2 Medidas em centmetros.
150
Notas:
1 As caixas externas (CE) tamanho 7, devem ser fixadas conforme figura 20.
2 A conexo do condutor de aterramento com o neutro de sada da medio deve ser realizada por meio de
conector tipo parafuso fendido de cobre ou cobreado e devidamente isolado.
3 A disposio dos eletrodutos de entrada e sada para caixas externas (CE) deve ser de acordo com a figura
22.
4 Para a conexo do condutor de proteo pode ser utilizado um barramento.
5 Medidas em centmetros.
Notas:
1 Aspectos construtivos, conforme item 9.5.
2 Instruo para a montagem da CED conforme item 9.4.1.
3 Numerar a CP de servio com o nmero da edificao.
4 O circuito de emergncia deve ser independente.
5 Medidas em centmetros.
151
Notas:
1 Aspectos construtivos, conforme item 9.5.
2 Instruo para a montagem da CED e/ou CD conforme item 9.4.1.
3 Numerar a CP de servio com o nmero da edificao.
4 O circuito de emergncia deve ser independente.
5 Medidas em centmetros.
152
Notas:
1 Aspectos construtivos, conforme item 9.5.
2 Instruo para a montagem da CED conforme item 9.4.1.
3 Numerar a CP de servio com o nmero Da edificao.
4 O circuito de emergncia deve ser independente.
5 Para a medio do servio, observar item 9.2.3 a.
6 Medidas em centmetros.
153
60
10
CP-2
CP-2
AP.n
Servio
CP-2
Emergncia
60
CED
DPS
CD
60
240 mnimo
circuito de distribuio
40
40
40
40
20
20
40
140
40
20
20
90
40
40
40
condutor de aterramento...mm
eletroduto ...mm
Rua "C"
rede da concessionria
40
330
condutor de entrada...mm
eletroduto ...mm
Rua "B"
40
120
B
C
Rua "A"
...m
dispositivo para
desligamento
distncia
A
120
mnimo
prdio a
ser ligado
prdio n
PLANTA DE SITUAO
Notas:
1 Aspectos construtivos, conforme item 9.5.
2 Instruo para a montagem da CED e/ou CD conforme item 9.4.1.
3 Numerar a CP de servio com o nmero da edificao.
4 O circuito de emergncia deve ser independente.
5 Para a medio do servio, observar item 9.2.3 a.
6 Medidas em centmetros.
LOCALIZAO DO PAINEL
154
letras cor
branca
bombas
sistema de
emergncia
CP - 2
pintura em
vermelho
distribuio
disjuntor
geral
entrada
CED
DIAGRAMAS UNIFILARES
DESLIGAMENTO DISTNCIA
CED
1
2
3
DESLIGAMENTO DISTNCIA
CED
155
1,8
20
20
20 10
20
20
20
20
20
20
10
10
1,8
1,8
identificao
15
SEO QUADRADA
Notas:
1 Os postes devem ser confeccionados conforme ANEXO Y.
2 Especificaes conforme ANEXO K.
3 Dimenses em centmetros.
13
16015
23
1,8
1,8
marca do
engastamento
110/120/130/135
marca do
engastamento
110/120/130/135
110/120/130/135
marca do
engastamento
SEO DUPLO T
500/600/700/750
500/600/700/750
1,8
16015
23
13
16015
500/600/700/750
15
identificao
identificao
SEO CIRCULAR
156
20
20
20
20
20 10
20 10
1,8
1,8
13
110/120/130
16015
23
500/600/700
Identificao
13
16015
1,8
Identificao
23
500/600/700
1,8
SEO CIRCULAR
SEO QUADRADA
Notas:
1 Postes de madeira devem ser de eucalipto tratado ou cerne.
2 Especificaes conforme ANEXO K.
3 Identificao:
- Nome do fabricante;
- Data da fabricao;
- Comprimento nominal;
- Dimetro do topo.
4 Dimenses em centmetros.
157
500/700
260/450 (Mn.)
500/600
Furo 5mm
Identificao
16015
Furo 30mm
para passagem
dos condutores
SEO CIRCULAR
Furo 15mm
para fio terra e
condutor de proteo
90/100
110/120
engastamento
Marca do
engastamento
SEO QUADRADA
Notas:
1 Os postes devem atender as exigncias da NBR 6591.
2 Os postes com caixa acoplada devem ser previamente liberados pela distribuidora.
3 Especificaes do poste com seo circular conforme ANEXO K.
4 Identificao:
- Nome do fabricante;
- Data da fabricao;
- Comprimento nominal;
- Dimetro do topo.
5 Dimenses em centmetros.
158
159
180X160
CAIXA SUBTERRNEA
DETALHE A-A
DETALHE B-B
CONDUTOR MULTIPLEX
AES-CEEE-RGE
DETALHE A-A
E
DETALHE B-B
34
DETALHE D-D
ESC. 1:5
DETALHE E-E
ESC. 1:5
Nota:
1 No caso do poste no possuir eletroduto interno, o ramal de entrada deve ser com cabo multipolar isolado
para 0,6/1 kV, no sendo aceito condutores unipolares;
2 Identificao:
- Nome do fabricante;
- Data da fabricao;
- Comprimento nominal;
- N do Registro de Responsabilidade Tcnica emitido pelo Conselho Habilitador;
Dimetro do topo.
3 Medidas em milmetros.
160
Modelo
CP 1
CP 2
CP 4
CD
CED/CD - 1
CED/CD - 2
A
150
260
480
300
400
600
Medidas (mm)
B
120
200
240
400
500
900
C
65
90
90
200
200
200
Notas:
1 Para escolha da CP consulte item 9.3.
2 Todas CEDs ou CDs devem ser dotadas de dobradias e dispositivos para lacre.
3 As aberturas para ventilao das CEDs e CDs devem estar localizadas nas faces laterais, inferior e superior,
com as aletas voltadas para o fundo.
161
Notas:
1 As caixas devem ser construdas em alvenaria com revestimentos de argamassa, ou em concreto e possuir
drenagem. Quando de concreto as paredes devem ter espessura mnima de 6cm.
2 As medidas indicadas so as mnimas exigidas. Para cada caso devem atender as condies do item 8.2.4.
3 Medidas em centmetros.
Nota:
Medidas em centmetros.
162
163
Notas:
1 As ferragens devem ser confeccionadas conforme especificao da distribuidora e atenderem as exigncias
aplicveis na NBR 8159;
2 Medidas em milmetros.
FIGURA 35 ISOLADORES
Roldana
76 x 80
Roldana
42 x 42 / 48 x 48
CASTANHA
60 x 40
ISOLADOR POLIMRICO
100 x 60
Nota:
Medidas em milmetros.
164
Nota:
Medidas mnimas em milmetros.
165
166
Nota:
A cavidade de inspeo pode ser confeccionada em alvenaria, concreto armado, policarbonato, plstico ou
produto similar, nos formatos quadrado ou circular, provido de tampa adequada com resistncia mecnica capaz
de suportar trnsito de veculos e/ou passagem de pedestres, quando localizado no passeio pblico.