DJ27 DJ28

16A 16A

- - - - - - ELÉTRICA

LEGENDA
RESERVA RESERVA

IDENTIFICAÇÃO DOS CIRCUITOS


DJ25 DJ26
20A 20A

POTÊNCIA LOCAL / TIPO / BITOLA


- RESERVA - - - - RESERVA - ID
(W) EQUIPAMENTO FIOS

DJ23 DJ24
10A 10A

DISJUNTOR TRIPOLAR
#1,5mm² ILUM. SUPERIOR 800 IL3 - - RESERVA - CAIXA MOLDADA

DR1
16A DJ21 DJ22
30mA 16A 10A MINIDISJUNTOR BIPOLAR
CURVA "C"
#1,5mm² ILUM. GER INF. 800 IL1 IL2 700 ILUM. SUITES INF. #1,5mm²

DR1 DR2
16A DJ19 DJ20 16A MINIDISJUNTOR
30mA 16A 16A 30mA MONOPOLAR CURVA "C"

#2,5mm² GERAL SUPERIOR 2000 T16 T19 1500 MLL SUPERIOR #2,5mm²
INTERRUPTOR DR 30mA
CAPACIDADE NOMINAL
INDICADA
DJ18
16A

#2,5mm² GERAL SUITES 1900 T10 T14 1500 GERAL SUITE SUP. #2,5mm²

DR1 DR2
16A DJ15 DJ16 16A
30mA 16A 16A 30mA

#2,5mm² GERAL INFERIOR 1500 T3 T6 1500 MLL INFERIOR #2,5mm²

DR2
DJ14 16A
16A 16A 30mA

#2,5mm² GERAL INFERIOR 1500 T1 T2 1100 GERAL INFERIOR #2,5mm²

16A DJ11 DJ12


30mA 16A 16A

#2,5mm² GERAL CHURR. 200 T17 T20 2000 AR COND SUP. #2,5mm²

DR1 DR2
16A DJ9 DJ10 16A
30mA 16A 16A 30mA

#2,5mm² FORNO 1500 T4 T5 2000 MICRO, COIFA #2,5mm²

DJ7 DJ8
20A 20A

#2,5mm² AR COND SUITE SUP. 2000 T15 T13 2000 AR COND SUITE 3 #2,5mm²

DJ5 DJ6
20A 20A
00 25.11.2018 EMISSÃO INICIAL
#2,5mm² AR COND SUITE 2 2000 T12 T11 2000 AR COND SUITE 1 #2,5mm² REV. DATA DESCRIÇÃO

DR2
DJ3 DJ4 25A
25A 25A 30mA

#4mm² AR COND 3 SALA 2800 T9 T18 3300 TRITURADOR #4mm² ANDRE BRITO

DJ1 DJ2 Tel: (21)97995 3709 / e-mail:


25A 25A
andreband2000@yahoo.com.br
#4mm² AR COND 1 SALA 2800 T7 T8 2800 AR COND 2 SALA #4mm²

CLIENTE DESENHO

GSR ANDRE
OBRA
DJG
ESCALA
125A
RESIDENCIAL- CASA 100 1:50

ASSUNTO FOLHA

R S T N Pe

VEM DA MEDIÇÃO 4x1C#35mm²(EPR/XLPE,


FASES, N)
1x1C#25mm²(Pe)
ILUM. E TOMADAS