Você está na página 1de 3

CÁLCULO DE VELOCIDADE EM TUBULAÇÕES

LOCAL DE INSTALAÇÃO
BOMBA :
MODELO DA BOMBA
Vazão Desejada (m3/h) 7560
Volume (m3) 200
Tempo de Descarga (s) 95

DN (pol) de (mm) e (mm) di (mm) A (mm2) V (m/s)


/4
1
13.70 2.24 9.22 66.77 31453.40
/8
3
17.10 2.31 12.48 122.33 17167.23
/2
1
21.30 2.77 15.76 195.08 10765.07
/4
3
26.70 2.87 20.96 345.04 6086.21
1 33.40 3.38 26.64 557.39 3767.57
11/4 42.20 3.56 35.08 966.52 2172.75
11/2 48.30 3.68 40.94 1316.39 1595.27
2 60.30 3.91 52.48 2163.10 970.83
21/2 73.00 5.16 62.68 3085.66 680.57
3 88.90 5.49 77.92 4768.57 440.38
31/2 101.60 5.74 90.12 6378.70 329.22
4 114.30 6.02 102.26 8212.99 255.69
5 141.30 6.55 128.20 12908.21 162.69
6 168.30 7.11 154.08 18645.86 112.63
8 219.10 8.18 202.74 32282.62 65.05
10 273.10 9.27 254.56 50894.42 41.26
12 323.90 10.41 303.08 72144.70 29.11
14 355.60 11.13 333.34 87269.95 24.06
16 406.40 12.70 381.00 114009.18 18.42
18 457.20 14.27 428.66 144316.44 14.55
20 508.00 15.09 477.82 179315.79 11.71
24 610.00 17.48 575.04 259708.40 8.09
30 762.00 17.48 727.04 415151.39 5.06
32 813.00 17.48 778.04 475437.83 4.42
34 864.00 17.48 829.04 539809.91 3.89
36 914.00 19.05 875.90 602558.11 3.49
CÁLCULO DE VELOCIDADE EM TUBULAÇÕES

LOCAL DE INSTALAÇÃO
BOMBA :
MODELO DA BOMBA
Vazão Desejada (m3/h) 300
Volume (m3) 200
Tempo de Descarga (s) 2400

DN (pol) de (mm) e (mm) di (mm) A (mm2) V (m/s)


/4
1
13.70 1.65 10.40 84.95 980.98
/8
3
17.10 1.65 13.80 149.57 557.15
/2
1
21.30 2.11 17.08 229.12 363.71
/4
3
26.70 2.11 22.48 396.90 209.96
1 33.40 2.77 27.86 609.61 136.70
11/4 42.20 2.77 36.66 1055.54 78.95
11/2 48.30 2.77 42.76 1436.04 58.03
2 60.30 3.05 54.20 2307.22 36.12
21/2 73.00 3.05 66.90 3515.14 23.71
3 88.90 3.05 82.80 5384.56 15.48
31/2 101.60 3.05 95.50 7163.03 11.63
4 114.30 3.05 108.20 9194.84 9.06
5 141.30 3.40 134.50 14208.05 5.87
6 168.30 3.40 161.50 20484.95 4.07
8 219.10 3.76 211.58 35159.21 2.37
10 273.10 4.19 264.72 55038.09 1.51
12 323.90 4.57 314.76 77812.43 1.07
14 355.60 4.78 346.04 94046.47 0.89
16 406.40 4.78 396.84 123686.06 0.67
18 457.20 4.78 447.64 157379.32 0.53
20 508.00 5.54 496.92 193937.97 0.43
22 559.00 5.54 547.92 235789.35 0.35
24 610.00 6.35 597.30 280204.37 0.30
30 762.00 7.92 746.16 437274.15 0.19
32 813.00 17.48 778.04 475437.83 0.18
34 864.00 17.48 829.04 539809.91 0.15
36 914.00 19.05 875.90 602558.11 0.14
CÁLCULO DE POTÊNCIA

LOCAL DE INSTALAÇÃO
BOMBA :
MODELO DA BOMBA

Aceleração da Gravidade (m/s2) 9.8


Massa Específica do Fluido (kg/m3) 1000
Vazão (m3/h) 150
Altura Manométrica (mca) 40
Rendimento (%) 73%

Potência (kW) 22.4


Potência (cv) 30.0