Você está na página 1de 14

N° Presion (± 0.05 ) (Bar) Caudal(±0.005)( LPM) RPM (± 0.

5)
1 0.6 148.25 3476
2 1.38 143.8 3455
3 3.4 30.2 3516
4 3.43 23.5 3520
5 3.5 15.29 3523
6 3.53 9.2 3526
0

ha Perdidas Succión(mca)

34.6065578690099
34.6231367873574
34.9722772235249
34.9810896908436
34.9889807300229
34.9930030090537
34.9959
0.695
1.08434213
1.06776321
0.71862278
0.70981031
0.70191927
0.69789699
0.695

0.38934213
0.37276321
0.02362278
0.01481031
0.00691927
0.00289699
0
Bar Metros de agua
Presion (± 0.509)(mca) 1 10.1974
6.11844 9810 100000
14.072412
34.67116 Curva característica y línea de pérdidas.
40
34.977082
35.6909 35
f(x) = −0.005763595674066
0.001503777737533
x +x²34.4432493023673
+ 0.047440828977258 x + 35.1315046793226
35.996822 Presión (MCA) 30

25

20
ha Perdidas Succión(mca) 15
0.389342130990125 Column F
10 Curva
0.372763212642571 Característica
0.023622776475127 5

0.014810309156359 0
0 20 40 60 80 100 120 140 160
0.006919269977124 Caudal (GPM)
0.002896990946266

0 34.437
9.2 34.439897
15.29 34.4468163
23.5 34.4616266
30.2 34.4852493
143.8 34.8580126
148.25 35.2473547
N° Presion (± 0.05 ) (Bar) Caudal(±0.005)( LPM) RPM (± 0.5)
1 0.6 148.25 3476
2 1.38 143.8 3455
3 3.4 30.2 3516
4 3.43 23.5 3520
5 3.5 15.29 3523
6 3.53 9.2 3526

Bar Metros de agua


1 10.1974
Peso especifico
9800
Presion (± 0.509)(mca) Caudal (±8.3*10^-8)(m3/s) Poh (Kw) ± Poh Po Mecanica (Kw)
6.11844 0.00247083 0.148152726031 5.012418930857 1.49
14.072412 0.00238708 0.3292013377222 5.011604416771 1.49
34.67116 0.00050132 0.1703371901258 4.9931401181894 1.49
34.977082 0.0003901 0.1337166849444 4.9920504020323 1.49
35.6909 0.000253814 0.0887767309075 4.9907153588656 1.49
35.996822 0.00015272 0.0538748596272 4.9897248775085 1.49
ʱ Eficiencia
9.94313598
22.0940495
11.4320262
8.97427416
5.95816986
3.61576239
Q= 148,25 LPM
Tramo Li (±0.0025)(m) Di P/µ V (m/s) Re f
1 0.203 0.0381 1000000 2.167 82562.7 0.019
2 0.086 0.0381 1000000
3 0.693 0.0381 1000000
4 0.086 0.0381 1000000
codo Li equivalente (m)
1 1.097 0.0381
2 1.097 0.0381

Q= 143,8 LPM
Tramo Li (±0.0025)(m) Di P/µ V (m/s) Re f
1 0.203 0.0381 1000000 2.093 79743.3 0.0195
2 0.086 0.0381 1000000
3 0.693 0.0381 1000000
4 0.086 0.0381 1000000
codo Li equivalente (m)
1 1.097 0.0381
2 1.097 0.0381

Q= 30,2 LPM
Tramo Li (±0.0025)(m) Di P/µ V (m/s) Re f
1 0.203 0.0381 1000000 0.4397 16752.57 0.028
2 0.086 0.0381 1000000
3 0.693 0.0381 1000000
4 0.086 0.0381 1000000
codo Li equivalente (m)
1 1.097 0.0381
2 1.097 0.0381

Q= 23,5 LPM
Tramo Li (±0.0025)(m) Di P/µ V (m/s) Re f
1 0.203 0.0381 1000000 0.3421 13034.01 0.029
2 0.086 0.0381 1000000
3 0.693 0.0381 1000000
4 0.086 0.0381 1000000
codo Li equivalente (m)
1 1.097 0.0381
2 1.097 0.0381
Q= 15,29 LPM
Tramo Li (±0.0025)(m) Di P/µ V (m/s) Re f
1 0.203 0.0381 1000000 0.2226 8481.06 0.032
2 0.086 0.0381 1000000
3 0.693 0.0381 1000000
4 0.086 0.0381 1000000
codo Li equivalente (m)
1 1.097 0.0381
2 1.097 0.0381

Q= 9,2 LPM
Tramo Li (±0.0025)(m) Di P/µ V (m/s) Re f
1 0.203 0.0381 1000000 0.13395 5103.495 0.037
2 0.086 0.0381 1000000
3 0.693 0.0381 1000000
4 0.086 0.0381 1000000
codo Li equivalente (m)
1 1.097 0.0381
2 1.097 0.0381
ha Perdidas (mca)
0.38934213099013

Caudal (±8.3*10^-8)(m3/s)
0.00247083 85.6167979 0.23934195
0.00238708 85.6167979 0.22327467
0.00050132 85.6167979 0.00985403
0.0003901 0.00596495
0.00025381 0.00252552
0.00015272 0.00091451

ha Perdidas (mca)
0.37276321264257

ha Perdidas (mca)
0.02362277647513

ha Perdidas (mca)
0.01481030915636
ha Perdidas (mca)
0.00691926997712

ha Perdidas (mca)
0.00289699094627
Caudal( LPM) Presión Atmosferica (Pa) Presión de Vapor (Pa) Ha Succión (mca)
148.25 101293 2339.274 0.165
143.8 101293 2339.274 0.165
30.2 101293 2339.274 0.165
23.5 101293 2339.274 0.165
15.29 101293 2339.274 0.165
9.2 101293 2339.274 0.165

9800
ha Perdidas Succión(mca) NPSH d (mca)
0.389342130990125 9.87297685
0.372763212642571 9.88955577
0.023622776475127 10.23869620
0.014810309156359 10.24750867
0.006919269977124 10.25539971
0.002896990946266 10.25942199

Você também pode gostar