Você está na página 1de 5

C

D
B

E
PLANTA BAIXA
ELEVAÇÃO 625,00m

42 20 20 70 20 20 28 176 49
156 156

51

50

50
12 132 12 12 132 12
40 40

12

12
EL.618,46 EL.618,46

5
20
EL.622,69 EL.622,69 5 60 5

40

40
23

23
5 166 5

A
28 86 18 28 86 18

234
156
132

156
132

124

124
86

86

92
EL.618,46 EL.618,46

40 40

23

23
EL.621,60

20
40

40
EL.618,56

5
12

12

51

50

50
42 20 20 5 60 5 20 20 28 5 166 5 49

444

PLANTA BAIXA
ELEVAÇÃO 621,98m

234 165 15

18
EL.618,56

30
12 12
156 156

15

15
8 8 12

8 8 12
EL.618,46 EL.618,46

35
EL.621,60
20

20

72
A
23 172 15

144
174
234
156

156

80
60

60

72
20

20
12 8 8

12 8 8

35
BTCC BTCC
Ø100 Ø100

15
15
12 12
BTCC
RADIER RADIER Ø150

30
18
RADIER
234 138 28 15

PLANTA BAIXA
ELEVAÇÃO 619,83m

234

18
EL.618,56

12 12
156 156
8 8 12

8 8 12

EL.618,46 EL.618,46

35
20

20

A
NOTAS:

234
156

156

80
60

60

1 - DIMENSÕES EM CENTÍMETRO, ELEVAÇÕES EM METRO, EXCETO ONDE INDICADO.


2 - A EXECUÇÃO DA ESTRUTURA, DEVERÁ OBEDECER AS PRESCRIÇÕES DA NBR-6118.

115
3 - TODAS AS MEDIDAS, ESPECIFICAÇÕES E INTERFERÊNCIAS DEVERÃO SER VERIFICADAS NA OBRA, E COTEJADAS
COM O PROJETO DIMENSIONAL CIVIL, E COM OS PROJETOS COMPLEMENTARES, ANTES DA EXECUÇÃO
20

20

4 - A DOSAGEM DO CONCRETO, DEVERÁ TER COMO BASE A RESISTÊNCIA CARACTERÍSTICA "fck" DESTE PROJETO,
12 8 8

12 8 8

BTCC BTCC SOB ASSISTÊNCIA DE UM TECNOLOGISTA (PROFISSIONAL) LEGALMENTE HABILITADO


Ø100 Ø100
5 - O PREPARO, CONTROLE E RECEBIMENTO DO CONCRETO DEVERÁ OBEDECER AS PRESCRIÇÕES DA NBR 12655
6 - AS FORMAS E ESCORAMENTOS, DEVERÃO SER PROJETADOS DE MODO A NÃO SOFREREM DEFORMAÇÕES

12 12
BTCC EXCESSIVAS DEVIDAS AO SEU PESO, AO PESO DO CONCRETO LANÇADO, E AS CARGAS ACIDENTAIS
RADIER RADIER Ø150 QUE POSSAM ATUAR DURANTE A EXECUÇÃO DA OBRA.
7 - PLANO DE CONCRETAGEM, SOB ORIENTAÇÃO DE UM TECNOLOGISTA EM CONCRETO

18
8 - NOS PRIMEIROS 7 DIAS A PARTIR DO LANÇAMENTO, DEVERÁ SER FEITA A CURA DO CONCRETO,
MANTENDO UMEDECIDA A SUPERFÍCIE OU PROTEGENDO-A COM PELÍCULA IMPERMEÁVEL
RADIER
9 - RECOMENDA-SE O USO DOS ESPAÇADORES, PARA GARANTIR O COBRIMENTO DAS BARRAS DE AÇO,
E A MANUTENÇÃO DAS DISTÂNCIAS ENTRE AS MESMAS
10 - COBRIMENTO ADOTADO: VIDE NOTA ARMAÇÃO.
-A EXECUÇÃO DEVERÁ OBEDECER UM CONTROLE RIGOROSO PARA GARANTIR O COBRIMENTO ESPECIFICADO.
Escala Gráfica 1: 25
11 - ANTES DE INICIAR A FUNDAÇÃO DEVERÁ SER OBSERVADO O PERFIL DE SONDAGEM ( SONDAGEL )

0 0,25 0,5 1m 12 - O PREPARO DA JUNTA E RETOMADA DA CONCRETAGEM DEVERÁ SE EXECUTADA CONFORME O CAPÍTULO 8.7.8
DO MANUAL DE ESPECIFIAÇÕES TÉCNICAS, REGULAMENTAÇÃO DE PREÇOS E CRITÉRIOS DE MEDIÇÃO DA CASAN.
13 - AS ESPECIFICAÇÕES CONTIDAS NESTE PROJETO NÃO PODERÃO SER ALTERADAS SEM A CONSULTA PRÉVIA AO PROJETISTA

LOGOMARCA DA CONSULTORA
NORTE
CONVENÇÕES ARTICULAÇÕES N° REVISÃO DATA Companhia Catarinense de Águas e Saneamento
- CONCRETO ESTRUTURAL : 40 MPa; FA/C : 0.45;
A EMISSÃO INICIAL 07/2022 REDE COLETORA DE ESGOTO SANITÁRIO
- CAA IV - MUITO ELEVADO;
LOTEAMENTO GARDENS - CHAPECÓ
- ECs - 38250910 kPa;
- COBRIMENTO :
- RADIER E FUNDAÇÕES :5 cm
VITAL
Engenharia e Meio Ambiente
PROJETO ESTRUTURAL

ESTAÇÃO ELEVATÓRIA DE ESGOTO - EEA


- VIGAS E PILARES :5 cm
- LAJES SUPERIORES :4,5 cm
01/05 DES. FORMAS - PLANTA BAIXA
VER.
APROV.
REV Nº 0 A B C D E F G
Nº DA CONSULTORA REV.

A SES-ELE-EST-0001-A
CORTE AA
627 627

D
B

E
PV018-DESARENADOR
150
20 110 20 EL.626,40

20
626 626

625 625

360
340
PÓRTICO PARA IÇAMENTO
DAS BOMBAS

624 624

82 5 60 5 68 5 166 5 49

10 20 10 10 20 10
623 132 132 623
EL.622,80

20

20
28 Ø86 18 28 Ø86 18
EL.622,69 EL.622,69

15 10

15 10
15

15
15

8 15

15

8 15
12 25 20 60 20 25 12
8 100 8 8 100 8

105
135
EL.621,98

95
99
622 622
100

100
EL.621,45

15

15
RADIER

CONCRETO MAGRO
12 150 12 18 10 167 15 30 10 MPa

100
621 621
100

100
VER NOTA 14

162
409
408

408
443

443

100
620 EL.619,88 620
100

100
EL.619,83 EL.619,83 EL.619,83

319
BTCC

43
Ø100
EL.619,40

65
BTCC
80

80
619 Ø150 619

84
BTCC
Ø100

35
EL.618,56
EL.618,46 EL.618,47
20

20

20

30

30

30
EL.618,26 8 20 20 8 EL.618,26 EL.618,26
5 20

20

5 20

20

RADIER RADIER RADIER

5
20 116 20 20 116 20 CONCRETO MAGRO
618
CONCRETO MAGRO CONCRETO MAGRO 30 12 35 80 35 12 30 10 MPa 618
10 MPa 10 MPa
156 156 234

VER NOTA 14

NOTAS:

1 - DIMENSÕES EM CENTÍMETRO, ELEVAÇÕES EM METRO, EXCETO ONDE INDICADO.


2 - A EXECUÇÃO DA ESTRUTURA, DEVERÁ OBEDECER AS PRESCRIÇÕES DA NBR-6118.
3 - TODAS AS MEDIDAS, ESPECIFICAÇÕES E INTERFERÊNCIAS DEVERÃO SER VERIFICADAS NA OBRA, E COTEJADAS
COM O PROJETO DIMENSIONAL CIVIL, E COM OS PROJETOS COMPLEMENTARES, ANTES DA EXECUÇÃO
4 - A DOSAGEM DO CONCRETO, DEVERÁ TER COMO BASE A RESISTÊNCIA CARACTERÍSTICA "fck" DESTE PROJETO,
SOB ASSISTÊNCIA DE UM TECNOLOGISTA (PROFISSIONAL) LEGALMENTE HABILITADO
5 - O PREPARO, CONTROLE E RECEBIMENTO DO CONCRETO DEVERÁ OBEDECER AS PRESCRIÇÕES DA NBR 12655
6 - AS FORMAS E ESCORAMENTOS, DEVERÃO SER PROJETADOS DE MODO A NÃO SOFREREM DEFORMAÇÕES
EXCESSIVAS DEVIDAS AO SEU PESO, AO PESO DO CONCRETO LANÇADO, E AS CARGAS ACIDENTAIS
QUE POSSAM ATUAR DURANTE A EXECUÇÃO DA OBRA.
7 - PLANO DE CONCRETAGEM, SOB ORIENTAÇÃO DE UM TECNOLOGISTA EM CONCRETO
8 - NOS PRIMEIROS 7 DIAS A PARTIR DO LANÇAMENTO, DEVERÁ SER FEITA A CURA DO CONCRETO,
MANTENDO UMEDECIDA A SUPERFÍCIE OU PROTEGENDO-A COM PELÍCULA IMPERMEÁVEL
9 - RECOMENDA-SE O USO DOS ESPAÇADORES, PARA GARANTIR O COBRIMENTO DAS BARRAS DE AÇO,
E A MANUTENÇÃO DAS DISTÂNCIAS ENTRE AS MESMAS
10 - COBRIMENTO ADOTADO: VIDE NOTA ARMAÇÃO.
NOTA 14 - TODA A BASE DE ACENTAMENTO DO RADIER, DEVER SER MUITO BEM COMPACTADA ATRAVÉS DE COMPACTADOR MECÂNICO MANUAL DO TIPO "SAPO" . -A EXECUÇÃO DEVERÁ OBEDECER UM CONTROLE RIGOROSO PARA GARANTIR O COBRIMENTO ESPECIFICADO.
Escala Gráfica 1: 25
SOBRE A BASE COMPACTADA PREVER O LANÇAMENTO DE UMA CAMADA DE CONCRETO MAGRO, FCK 10 MPa, DE NO MÍNIMO 5 cm DE ESPESSURA. 11 - ANTES DE INICIAR A FUNDAÇÃO DEVERÁ SER OBSERVADO O PERFIL DE SONDAGEM ( SONDAGEL )

0 0,25 0,5 1m 12 - O PREPARO DA JUNTA E RETOMADA DA CONCRETAGEM DEVERÁ SE EXECUTADA CONFORME O CAPÍTULO 8.7.8
DO MANUAL DE ESPECIFIAÇÕES TÉCNICAS, REGULAMENTAÇÃO DE PREÇOS E CRITÉRIOS DE MEDIÇÃO DA CASAN.
13 - AS ESPECIFICAÇÕES CONTIDAS NESTE PROJETO NÃO PODERÃO SER ALTERADAS SEM A CONSULTA PRÉVIA AO PROJETISTA

LOGOMARCA DA CONSULTORA
NORTE
CONVENÇÕES ARTICULAÇÕES N° REVISÃO DATA Companhia Catarinense de Águas e Saneamento
- CONCRETO ESTRUTURAL : 40 MPa; FA/C : 0.45;
A EMISSÃO INICIAL 07/2022 REDE COLETORA DE ESGOTO SANITÁRIO
- CAA IV - MUITO ELEVADO;
LOTEAMENTO GARDENS - CHAPECÓ
- ECs - 38250910 kPa;
- COBRIMENTO :
- RADIER E FUNDAÇÕES :5 cm
VITAL Engenharia e Meio Ambiente
PROJETO ESTRUTURAL

ESTAÇÃO ELEVATÓRIA DE ESGOTO - EEA


- VIGAS E PILARES :5 cm
- LAJES SUPERIORES :4,5 cm
01/05 DES. FORMAS - CORTE AA
VER.
APROV.
REV Nº 0 A B C D E F G
Nº DA CONSULTORA REV.

A SES-ELE-EST-0002-A
CORTE BB CORTE CC CORTE DD
627 627

A
A
PV018-DESARENADOR
132
20 92 20 EL.626,40

EL.626,20

20
20
626 626

MONOVIA
PERFIL I

20 92 20 168

625 625

PÓRTICO PARA IÇAMENTO


DAS BOMBAS

320
624 624

CORTE EE

234
623 132 132 623
50 5 124 5 50
23 Ø85 23 23 Ø85 23 50 5 124 5 50 EL.622,80 EL.622,80
EL.622,69 EL.622,69

15 10

15 10
15

15

15
15

8 15

15

8 15
10 124 10
12
8 100 8 8 100 8

67
57

135

105
EL.621,98 EL.621,98

95
622 622
100

100

42
CONCRETO MAGRO
10 MPa
EL.621,45

5 15

15
RADIER
12 150 12
30 15 144 15 30
234

100
621 621
100

100
VER NOTA 14

215
409
408

408
443

443

100
620 EL.619,88 EL.619,88 620
100

100

EL.619,83

BTCC BTCC
Ø100 Ø100

65

127
80

80

BTCC
619 Ø150 619

35
EL.618,56
EL.618,46 EL.618,46
20

20

30

30

30
EL.618,26 EL.618,26 EL.618,26
5 20

20

5 20

20

RADIER RADIER RADIER

5
20 116 20 CONCRETO MAGRO 20 116 20 CONCRETO MAGRO 30 12 35 80 35 12 30 CONCRETO MAGRO
618 10 MPa 10 MPa 10 MPa 618
156 156
234

VER NOTA 14 VER NOTA 14

NOTAS:

1 - DIMENSÕES EM CENTÍMETRO, ELEVAÇÕES EM METRO, EXCETO ONDE INDICADO.


2 - A EXECUÇÃO DA ESTRUTURA, DEVERÁ OBEDECER AS PRESCRIÇÕES DA NBR-6118.
3 - TODAS AS MEDIDAS, ESPECIFICAÇÕES E INTERFERÊNCIAS DEVERÃO SER VERIFICADAS NA OBRA, E COTEJADAS
COM O PROJETO DIMENSIONAL CIVIL, E COM OS PROJETOS COMPLEMENTARES, ANTES DA EXECUÇÃO
4 - A DOSAGEM DO CONCRETO, DEVERÁ TER COMO BASE A RESISTÊNCIA CARACTERÍSTICA "fck" DESTE PROJETO,
SOB ASSISTÊNCIA DE UM TECNOLOGISTA (PROFISSIONAL) LEGALMENTE HABILITADO
5 - O PREPARO, CONTROLE E RECEBIMENTO DO CONCRETO DEVERÁ OBEDECER AS PRESCRIÇÕES DA NBR 12655
6 - AS FORMAS E ESCORAMENTOS, DEVERÃO SER PROJETADOS DE MODO A NÃO SOFREREM DEFORMAÇÕES
EXCESSIVAS DEVIDAS AO SEU PESO, AO PESO DO CONCRETO LANÇADO, E AS CARGAS ACIDENTAIS
QUE POSSAM ATUAR DURANTE A EXECUÇÃO DA OBRA.
7 - PLANO DE CONCRETAGEM, SOB ORIENTAÇÃO DE UM TECNOLOGISTA EM CONCRETO
NOTA 14 - TODA A BASE DE ACENTAMENTO DO RADIER, DEVER SER MUITO BEM COMPACTADA ATRAVÉS DE COMPACTADOR MECÂNICO MANUAL DO TIPO "SAPO" . 8 - NOS PRIMEIROS 7 DIAS A PARTIR DO LANÇAMENTO, DEVERÁ SER FEITA A CURA DO CONCRETO,
SOBRE A BASE COMPACTADA PREVER O LANÇAMENTO DE UMA CAMADA DE CONCRETO MAGRO, FCK 10 MPa, DE NO MÍNIMO 5 cm DE ESPESSURA. MANTENDO UMEDECIDA A SUPERFÍCIE OU PROTEGENDO-A COM PELÍCULA IMPERMEÁVEL
9 - RECOMENDA-SE O USO DOS ESPAÇADORES, PARA GARANTIR O COBRIMENTO DAS BARRAS DE AÇO,
E A MANUTENÇÃO DAS DISTÂNCIAS ENTRE AS MESMAS
10 - COBRIMENTO ADOTADO: VIDE NOTA ARMAÇÃO.
-A EXECUÇÃO DEVERÁ OBEDECER UM CONTROLE RIGOROSO PARA GARANTIR O COBRIMENTO ESPECIFICADO.
Escala Gráfica 1: 25
11 - ANTES DE INICIAR A FUNDAÇÃO DEVERÁ SER OBSERVADO O PERFIL DE SONDAGEM ( SONDAGEL )

0 0,25 0,5 1m 12 - O PREPARO DA JUNTA E RETOMADA DA CONCRETAGEM DEVERÁ SE EXECUTADA CONFORME O CAPÍTULO 8.7.8
DO MANUAL DE ESPECIFIAÇÕES TÉCNICAS, REGULAMENTAÇÃO DE PREÇOS E CRITÉRIOS DE MEDIÇÃO DA CASAN.
13 - AS ESPECIFICAÇÕES CONTIDAS NESTE PROJETO NÃO PODERÃO SER ALTERADAS SEM A CONSULTA PRÉVIA AO PROJETISTA

LOGOMARCA DA CONSULTORA
NORTE
CONVENÇÕES ARTICULAÇÕES N° REVISÃO DATA Companhia Catarinense de Águas e Saneamento
- CONCRETO ESTRUTURAL : 40 MPa; FA/C : 0.45;
A EMISSÃO INICIAL 07/2022 REDE COLETORA DE ESGOTO SANITÁRIO
- CAA IV - MUITO ELEVADO;
LOTEAMENTO GARDENS - CHAPECÓ
- ECs - 38250910 kPa;
- COBRIMENTO :
- RADIER E FUNDAÇÕES :5 cm
VITAL
Engenharia e Meio Ambiente
PROJETO ESTRUTURAL

ESTAÇÃO ELEVATÓRIA DE ESGOTO - EEA


- VIGAS E PILARES :5 cm
- LAJES SUPERIORES :4,5 cm
01/05 DES. FORMAS - CORTE BB / CORTE CC / CORTE DD / CORTE EE
VER.
APROV.
REV Nº 0 A B C D E F G
Nº DA CONSULTORA REV.

A SES-ELE-EST-0003-A
C

D
B
DETALHE DA MÍSULA INTERNA
RADIER DESARENADOR RADIER COMPORTA RADIER EEA
16A3Ø10c.15C-264
224

20

20
AJUSTAR CIRCUNFERÊNCIA IN-LOCO AJUSTAR CIRCUNFERÊNCIA IN-LOCO

20

20
12A1Ø8c.13C-166 12A1Ø8c.13C-166 224
A2' A2'

10

10

10

10
37A1Ø8c.10C-55 146 37A1Ø8c.10C-55 146 16A3Ø10c.15C-264

A6
A1' A1'

10

10

10

10
32

32
146 146

23

23
A4 A4 A3
12A1Ø8c.13C-166 12A1Ø8c.13C-166 20 20

31A5Ø10c.15C-116 A5 RADIER
10 10 10 10
A3 A3 A4

68
48
4A2Ø6.3C-400AJUSTAR CIRCUNFERÊNCIA IN-LOCO

4A2Ø6.3C-400AJUSTAR CIRCUNFERÊNCIA IN-LOCO


A6
A4

16A4Ø10c.15C-264

16A4Ø10c.15C-264
12A2Ø8c.13C-166

12A2Ø8c.13C-166

12A2Ø8c.13C-166

12A2Ø8c.13C-166
A1 A1

A2 A2
146

146

146

146

146

146

224

224

224
A1

A1

A3
6A6Ø6.3c.15C-600 AJUSTAR CIRCUNFERÊNCIA IN-LOCO
600

10 10 10 10
A2 A2
146 146
400

400
20 20
A4
224
TAMPO COMPORTA
TAMPO DESARENADOR
62 6.3 CE
62

12
3
C-
1Ø FA

A1
PO

2Ø 3A7Ø6.3C-134
R
A1 R
12 PO

48 6.
FA

7A8Ø5c.15C-49 7A8Ø5c.15C-49
6

6
62 6.3 CE
3C 122 122

62
12
C

3
3

6 6
E

-4

C-
1Ø FA
A1

PO
8 122 2Ø 122

R
R
13

13
6

6
PO
48 6.

FA
5

5
3A7Ø6.3C-134 3C 3A7Ø6.3C-134

C
A1
3
TAMPO EEA

E
-4

12
8
A8 A8
6 6 6 6 6 6 6 6 DT.01
DETALHE DO ENCAIXE DO TAMPO

A13
laje supeiror 55A21Ø6.3c.10C-66 48A22Ø6.3c.10C-43
A7 A7 A7 A7 A7 A7
6
Ø 6.3
4A7Ø6.3C-134

4A7Ø6.3C-134

2A7Ø6.3C-134

2A7Ø6.3C-134

4A7Ø6.3C-134

4A7Ø6.3C-134

2A7Ø6.3C-134

2A7Ø6.3C-134
A1 2 A1 2 corrido

16
A1 A1

2
1 1 Ø 6.3

6
corrido 16

19A19Ø6.3c.10C-53

19A19Ø6.3c.10C-53
7A10Ø5c.15C-39 7A10Ø5c.15C-39 11
122
122

122
122

122
122

122
122

9A18Ø8c.10C-53

9A18Ø8c.10C-53
A9 A10 A9 A10 6 6 6 6 6 6 6 6
6

6
5 5
8 8
1 A1 1 A1
A1 2 A1 2

41
41

41
41
41
A13 A18

A14
A19
6 6 6 6
6 6 6 6 6 6 6 6
A7 A8 A7 A8

5A20Ø6.3c.10C-237

5A20Ø6.3c.10C-237
15A17Ø8c.10C-237

15A17Ø8c.10C-237
7A9Ø5c.15C-59 3A7Ø6.3C-134 7A8Ø5c.15C-49 7A9Ø5c.15C-59 3A7Ø6.3C-134 7A8Ø5c.15C-49
6 6
6

6
122 122
6

6
5 5 A14 A15 A16
18 18
13

13
122 122
6

143

225

225

225

225
5

5
3A7Ø6.3C-134 3A7Ø6.3C-134

A13
A17 A17 A20
DETALHAMENTO DO PÓRTICO
QUANTITATIVO PARA 01 PÓRTICO

19A19Ø6.3c.10C-53

19A19Ø6.3c.10C-53
2A28Ø10C-200

9A18Ø8c.10C-53

9A18Ø8c.10C-53
6 6 6 6
140
30

30

41

41
41

41
41
13A27Ø5c.10C-60
A13

10
A18 A19
10

10
2A29Ø10C-160 10
6 6 6 6 6 6 6 6
140 A13 A18 A17 A19 A20
A28 73 79 59 185 40
10 10

10A13Ø8c.10C-447

6
DETALHAMENTO DA BASE DO A29 435
A27 10A13Ø8c.10C-447

6
PÓRTICO 120
435

15A14Ø8c.10C-85 15A15Ø8c.10C-71 15A16Ø6.3c.10C-52


59

6
6

6
73 40
73 59

6
40

6
15A14Ø8c.10C-85 15A15Ø8c.10C-71 15A16Ø6.3c.10C-52

A23 A23
16A23Ø10C-99
28
25

26

35A27Ø5c.10C-60

35A27Ø5c.10C-60
4A26Ø10C-390

4A26Ø10C-390

A24 A24
A27

A27
340

340

A26 A26
10 10 NOTAS:
365

365
10

10

16A24Ø10C-99 1 - DIMENSÕES EM CENTÍMETRO, ELEVAÇÕES EM METRO, EXCETO ONDE INDICADO.


10 10
28 2 - A EXECUÇÃO DA ESTRUTURA, DEVERÁ OBEDECER AS PRESCRIÇÕES DA NBR-6118.
25

26

3 - TODAS AS MEDIDAS, ESPECIFICAÇÕES E INTERFERÊNCIAS DEVERÃO SER VERIFICADAS NA OBRA, E COTEJADAS


COM O PROJETO DIMENSIONAL CIVIL, E COM OS PROJETOS COMPLEMENTARES, ANTES DA EXECUÇÃO
10 10 4 - A DOSAGEM DO CONCRETO, DEVERÁ TER COMO BASE A RESISTÊNCIA CARACTERÍSTICA "fck" DESTE PROJETO,
SOB ASSISTÊNCIA DE UM TECNOLOGISTA (PROFISSIONAL) LEGALMENTE HABILITADO
PERIMETRAL
5 - O PREPARO, CONTROLE E RECEBIMENTO DO CONCRETO DEVERÁ OBEDECER AS PRESCRIÇÕES DA NBR 12655
12A25Ø8C-140 A24
6 - AS FORMAS E ESCORAMENTOS, DEVERÃO SER PROJETADOS DE MODO A NÃO SOFREREM DEFORMAÇÕES
EXCESSIVAS DEVIDAS AO SEU PESO, AO PESO DO CONCRETO LANÇADO, E AS CARGAS ACIDENTAIS
30

QUE POSSAM ATUAR DURANTE A EXECUÇÃO DA OBRA.


A23 A23 7 - PLANO DE CONCRETAGEM, SOB ORIENTAÇÃO DE UM TECNOLOGISTA EM CONCRETO
30
8 - NOS PRIMEIROS 7 DIAS A PARTIR DO LANÇAMENTO, DEVERÁ SER FEITA A CURA DO CONCRETO,
MANTENDO UMEDECIDA A SUPERFÍCIE OU PROTEGENDO-A COM PELÍCULA IMPERMEÁVEL

DT.02 9 - RECOMENDA-SE O USO DOS ESPAÇADORES, PARA GARANTIR O COBRIMENTO DAS BARRAS DE AÇO,
E A MANUTENÇÃO DAS DISTÂNCIAS ENTRE AS MESMAS
BASE PÓRTICO
10 - COBRIMENTO ADOTADO: VIDE NOTA ARMAÇÃO.
A24
-A EXECUÇÃO DEVERÁ OBEDECER UM CONTROLE RIGOROSO PARA GARANTIR O COBRIMENTO ESPECIFICADO.
15 15
Escala Gráfica 1: 25
11 - ANTES DE INICIAR A FUNDAÇÃO DEVERÁ SER OBSERVADO O PERFIL DE SONDAGEM ( SONDAGEL )
A25 A23 A25
0 0,25 0,5 1m 12 - O PREPARO DA JUNTA E RETOMADA DA CONCRETAGEM DEVERÁ SE EXECUTADA CONFORME O CAPÍTULO 8.7.8
DO MANUAL DE ESPECIFIAÇÕES TÉCNICAS, REGULAMENTAÇÃO DE PREÇOS E CRITÉRIOS DE MEDIÇÃO DA CASAN.
13 - AS ESPECIFICAÇÕES CONTIDAS NESTE PROJETO NÃO PODERÃO SER ALTERADAS SEM A CONSULTA PRÉVIA AO PROJETISTA

LOGOMARCA DA CONSULTORA
NORTE
CONVENÇÕES ARTICULAÇÕES N° REVISÃO DATA Companhia Catarinense de Águas e Saneamento
- CONCRETO ESTRUTURAL : 40 MPa; FA/C : 0.45;
A EMISSÃO INICIAL 07/2022 REDE COLETORA DE ESGOTO SANITÁRIO
- CAA IV - MUITO ELEVADO;
LOTEAMENTO GARDENS - CHAPECÓ
- ECs - 38250910 kPa;
- COBRIMENTO :
- RADIER E FUNDAÇÕES :5 cm
VITAL
Engenharia e Meio Ambiente
PROJETO ESTRUTURAL

ESTAÇÃO ELEVATÓRIA DE ESGOTO - EEA


- VIGAS E PILARES :5 cm
- LAJES SUPERIORES :4,5 cm
01/05 DES. ARMADURA - PLANTA E DETALHAMENTOS DIVEROS
VER.
APROV.
REV Nº 0 A B C D E F G
Nº DA CONSULTORA REV.

A SES-ELE-EST-0004-A
BARRILHETE EEA

CORTE DD
627

EL.626,40
LISTA DE BARRAS RADIER
A28 A28
Esquematico Pos. Bit. Q.Tot. Dobra Reto Dobra C.Unt. Peso

6A31Ø6.3c.10
(mm) (cm) (cm) (cm) (cm) (kg) 5 5

6A31Ø6.3c.10
EL.626,20 8A30Ø6.3c.10 (257-210)
A27 A27

(20-62)
(20-62)

VAR.

5
VAR.

VAR.
1' 8 74 22.9 32.0 55.0 15.97
A29 A29 8A30Ø6.3c.10 (257-210)

5
626 VAR.
1 8 48 10.0 146.0 10.0 166.0 31.27 5 5
MONOVIA
PERFIL I EL.618,56 57 205
2' 6.3 8 400.0 400.0 7.91 A31 A32
5 5
2 8 48 10.0 146.0 10.0 166.0 31.27
A31 A32 EL.621,60
3 10 32 20.0 224.0 20.0 264.0 53.05

A30
82
A30

21A32Ø6.3c.10C-174
21A32Ø6.3c.10C-174
625
4 10 32 20.0 224.0 20.0 264.0 53.05

164

164
PÓRTICO PARA IÇAMENTO
5 10 31 47.9 68.0 116.0 22.58
DAS BOMBAS

6 6.3 6 600.0 600.0 8.90

A30
82
7 6.3 45 6.0 122.0 6.0 134.0 14.91
A31 A30
624
8 5 28 49.0 2.15
BTCC 5 5
Ø150
9 5 14 59.0 1.30 A31 A32
57 205
10 5 14 39.0 0.86
RADIER

6A31Ø6.3c.10
CORTE BB 11 6.3 24 62.0 62.0 3.68

6A31Ø6.3c.10
CORTE CC 5 5 VAR.

(20-62)

5
VAR.
(20-62)
8A30Ø6.3c.10 (257-210)

VAR.
623
EL.622,80 12 6.3 24 48.0 48.0 2.85 VAR.

5
A13 A13
EL.622,69 EL.622,69 8A30Ø6.3c.10 (257-210)
A7 A7 A7 A7
A18 A18 5 5
13 8 20 447.0 35.09
A8 A8 A8 A8 A21 A21
A13 A13
A7 A7 A7 A7 Ø 6.3 Ø 6.3 14 8 30 85.0 10.01
corrido corrido

15 8 30 6.0 59.0 6.0 71.0 8.36

622
16 6.3 30 6.0 40.0 6.0 52.0 3.86 PAREDES LATERAIS
13A33Ø6.3c.10C-266

5
17 8 30 6.0 225.0 6.0 237.0 27.91 10 251
13A34Ø6.3c.10C-257

5
10
18 8 36 6.0 41.0 6.0 53.0 7.49 242

19 6.3 76 6.0 41.0 6.0 53.0 9.96 EL.618,56


A36 A36 A33 A36
621 5 5
20 6.3 10 6.0 225.0 6.0 237.0 5.86
5

A36 A36 A34 A36


21 6.3 55 66.0 8.98

140A36Ø6.3c.10C-135
A36

A36

13A35Ø6.3c.10C-174

13A35Ø6.3c.10C-174
22 6.3 48 43.0 5.10

125
23 10 16 99.0 9.95

164

164
EL.621,60
A35 A35
620 EL.619,88 EL.619,88 EL.619,88
24 10 16 99.0 9.95

A36

A36
BTCC BTCC 25 8 12 140.0 6.59
Ø100 Ø100
A36 A36 A34 A36 5
26 10 16 10.0 365.0 15.0 390.0 39.19

BTCC 5 5
27 5 166 60.0 15.64 Ø150
A36 A36 A33 A36
BTCC
619 Ø150
28 10 4 30.0 140.0 30.0 200.0 5.02
RADIER
242
A6
10
A6

5
A3 A3 A3 EL.618,56 29 10 4 10.0 140.0 10.0 160.0 4.02 13A34Ø6.3c.10C-257
A2' A2' EL.618,46 A2' A2' EL.618,46
A1 A1 10 251

5
30 6.3 32 5.0 _VAR_ 5.0 _VAR_ 18.44 13A33Ø6.3c.10C-266
RADIER EL.618,26 RADIER EL.618,26 A5 RADIER A5 EL.618,26
A1' A1' A1' A1'

A2 A1 A1 A2 A1 A1 A4 A3 31 6.3 24 5.0 _VAR_ 5.0 _VAR_ 2.31


A3

618
32 6.3 42 5.0 164.0 5.0 174.0 18.07

33 6.3 26 10.0 251.0 5.0 266.0 17.10

34 6.3 26 10.0 242.0 5.0 257.0 16.52

NOTAS:
35 6.3 26 5.0 164.0 5.0 174.0 11.19
CORTE EE 1 - DIMENSÕES EM CENTÍMETRO, ELEVAÇÕES EM METRO, EXCETO ONDE INDICADO.
2 - A EXECUÇÃO DA ESTRUTURA, DEVERÁ OBEDECER AS PRESCRIÇÕES DA NBR-6118.
A19 A13 A22 A22 A13 A19 EL.622,80 36 6.3 140 5.0 125.0 5.0 135.0 46.73
3 - TODAS AS MEDIDAS, ESPECIFICAÇÕES E INTERFERÊNCIAS DEVERÃO SER VERIFICADAS NA OBRA, E COTEJADAS
COM O PROJETO DIMENSIONAL CIVIL, E COM OS PROJETOS COMPLEMENTARES, ANTES DA EXECUÇÃO
4 - A DOSAGEM DO CONCRETO, DEVERÁ TER COMO BASE A RESISTÊNCIA CARACTERÍSTICA "fck" DESTE PROJETO,
Ø 6.3 Ø 6.3 SOB ASSISTÊNCIA DE UM TECNOLOGISTA (PROFISSIONAL) LEGALMENTE HABILITADO
A13 corrido corrido A13
5 - O PREPARO, CONTROLE E RECEBIMENTO DO CONCRETO DEVERÁ OBEDECER AS PRESCRIÇÕES DA NBR 12655
RESUMO GERAL (+10%) 6 - AS FORMAS E ESCORAMENTOS, DEVERÃO SER PROJETADOS DE MODO A NÃO SOFREREM DEFORMAÇÕES
EXCESSIVAS DEVIDAS AO SEU PESO, AO PESO DO CONCRETO LANÇADO, E AS CARGAS ACIDENTAIS
COMPR (m) MASSA (kg)
Ø5 139.74m 21.94 kg QUE POSSAM ATUAR DURANTE A EXECUÇÃO DA OBRA.
A33 A34 A34 A33 EL.621,98 Ø6.3 900.28m 222.62 kg
Ø8 487.56m 191.37 kg 7 - PLANO DE CONCRETAGEM, SOB ORIENTAÇÃO DE UM TECNOLOGISTA EM CONCRETO
Ø10.1 344.74m 216.50 kg 8 - NOS PRIMEIROS 7 DIAS A PARTIR DO LANÇAMENTO, DEVERÁ SER FEITA A CURA DO CONCRETO,
CA-50A 630.48 kg MANTENDO UMEDECIDA A SUPERFÍCIE OU PROTEGENDO-A COM PELÍCULA IMPERMEÁVEL
A36 A36 CA-60B 21.94 kg
A35 A30 9 - RECOMENDA-SE O USO DOS ESPAÇADORES, PARA GARANTIR O COBRIMENTO DAS BARRAS DE AÇO,
A36 A36 TOTAL: 652.42 kg
E A MANUTENÇÃO DAS DISTÂNCIAS ENTRE AS MESMAS
EL.621,45
10 - COBRIMENTO ADOTADO: VIDE NOTA ARMAÇÃO.
-A EXECUÇÃO DEVERÁ OBEDECER UM CONTROLE RIGOROSO PARA GARANTIR O COBRIMENTO ESPECIFICADO.
Escala Gráfica 1: 25 A35 A30 11 - ANTES DE INICIAR A FUNDAÇÃO DEVERÁ SER OBSERVADO O PERFIL DE SONDAGEM ( SONDAGEL )

0 0,25 0,5 1m 12 - O PREPARO DA JUNTA E RETOMADA DA CONCRETAGEM DEVERÁ SE EXECUTADA CONFORME O CAPÍTULO 8.7.8
DO MANUAL DE ESPECIFIAÇÕES TÉCNICAS, REGULAMENTAÇÃO DE PREÇOS E CRITÉRIOS DE MEDIÇÃO DA CASAN.
13 - AS ESPECIFICAÇÕES CONTIDAS NESTE PROJETO NÃO PODERÃO SER ALTERADAS SEM A CONSULTA PRÉVIA AO PROJETISTA

LOGOMARCA DA CONSULTORA
NORTE
CONVENÇÕES ARTICULAÇÕES N° REVISÃO DATA Companhia Catarinense de Águas e Saneamento
- CONCRETO ESTRUTURAL : 40 MPa; FA/C : 0.45;
A EMISSÃO INICIAL 07/2022 REDE COLETORA DE ESGOTO SANITÁRIO
- CAA IV - MUITO ELEVADO;
LOTEAMENTO GARDENS - CHAPECÓ
- ECs - 38250910 kPa;
- COBRIMENTO :
- RADIER E FUNDAÇÕES :5 cm
VITAL
Engenharia e Meio Ambiente ESTAÇÃO ELEVATÓRIA DE ESGOTO - EEA
PROJETO ESTRUTURAL

- VIGAS E PILARES :5 cm
- LAJES SUPERIORES :4,5 cm
01/05 DES. ARMADURA - CORTES E DETALHAMENTOS DIVEROS
VER.
APROV.
REV Nº 0 A B C D E F G
Nº DA CONSULTORA REV.

A SES-ELE-EST-0005-A