Você está na página 1de 6

Porta

M/D40
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40

Frequency
(THz)
196.00
195.90
195.80
195.70
195.60
195.50
195.40
195.30
195.20
195.10
195.00
194.90
194.80
194.70
194.6
194.5
194.4
194.3
194.2
194.1
194.00
193.90
193.80
193.70
193.60
193.50
192.40
193.30
193.20
193.10
193.00
192.90
195.80
192.70
192.60
195.50
192.40
192.30
192.20
192.10

Wavelength
(nm)
1529.55
1530.33
1531.12
1531.90
1532.68
1533.47
1534.25
1535.04
1535.82
1536.61
1537.40
1538.19
1538.98
1539.77
1540.56
1541.35
1542.14
1542.94
1543.73
1544.52
1545.32
1546.11
1546.91
1547.71
1548.51
1549.31
1550.12
1550.92
1551.72
1552.52
1553.33
1554.13
1554.94
1555.75
1556.55
1557.37
1558.17
1558.98
1559.79
1560.60

Sub-band

C01

C02

C03

C04
Comandos Navigator
C05

C06

C07

C08

C09

C10

:cm-get-ip: - verifica ip do eqpto


:cm-set-ip: -seta IP do eqpto
:cm-get-neid: -verifica NEID do eqpto.
:cm-set-neid: 0x09YYYY-seta NEID do eqpto (tem que converter para
tem um botao no navigator que e uma calculadora, abre ela, coloc
copia os 4 ultimos numeros do NE ID (hex) e completa nesta seque
:cm-get-submask: - verifica submascara do NE
:cm-set-submask: - seta a submascara do NE
:cm-get-gateway: - verifica gateway do NE
:cm-set-gateway: - seta gateway do NE
:ver - ver versao de SW do eqpto
:sftm-get-nesoftver:XX - ver sw especifico da placa (XX e o SL da plac
:sftm-start-nesoft:XX,nsf2 - starta o software da placa (XX e o nro da
:cfg-get-nestate - ver estado do NE
:sftm-set-loadsoft:open - habilita
:sftm-check-file:18,"/ofs1/hwx/extbios.hwx" - faz checkup ARQUIVO d
:sftm-show-dir:18,"/ofs1/hwx/" - lista arquivos contidos em local espe
:cfg-get-board: - ve as placas instaladas logicamente
:cfg-add-board:11, tn81ex2 - adiciona placa (SL, TIPO)
:cfg-del-board: - deleta placa
:cfg-set-wavelen:1-14,1,1,cband,80 (seta freq da transponder)
:cfg-get-gain:1-7,4,1 - ve ganho da porta (SL/PT/PATH) onde patch ge
:cfg-set-stdgain:8,4,1,200 - altera ganho da porta (SL/PT/PATH) onde
(200 ex de ganho, recomenda-se ver antes qual o ganho que
portas padrao para esta comando:
tn11oau1: 4
tn11obu1: 2
tn11obu2: 2
tn11hba : 2

que converter para hexadecimal)


dora, abre ela, coloca o NEID em decimal no campo NE ID(dec) e da enter
ompleta nesta sequencia 0x09.... (ex: se for 3333 em dec, fica 0x090D05)

ca (XX e o SL da placa ex:07)


laca (XX e o nro da placa ex:07) (nsf2: banco que est na nfs2)

checkup ARQUIVO do SW da placa. (SL,"/local")


ntidos em local especificado. (SL,"/local")
ente
TIPO)

transponder)
ATH) onde patch geralmente = 1
(SL/PT/PATH) onde patch geralmente = 1
es qual o ganho que est)

Passos do navigator para upgrade (resumido)


Checar espao livre na memoria, maior q 30M
:sftm-get-freespace:bid,"cfs1"
Verifique o estado do NE (main state):
:sftm-rtrv-state:swdl
Se estiver estado normal-->
:cfg-verify
:cfg-get-nestate (precisa estar em running)
Se ele estiver no estado: -->
MAIN_STATE is CPY_FILE_END and SUB_STAT is
NORMAL.
Insira o comando abaixo:
:swdl-dnld-swmem
Aps verifique novamente o estado :

:sftm-rtrv-state:swdl
Se ele estiver em:
MAIN_STATE is CPY_MEM_END and SUB_STAT is
NORMAL.
D o comando abaixo para ativar o software nas placas:
:mon-init-sys:0,swdl
Depois disso insira o comando abaixo:
:swdl-commit-swmem

:sm-set-lctaces:enable
:cm-set-lanautoecc:open

upgrade (resumido)

maior q 30M
d,"cfs1"
ate):

estar em running)

and SUB_STAT is

do :
and SUB_STAT is

var o software nas placas:

baixo:

UPGRADE OSN6800 Data Center V2R7C01SP006

Ferramentas(Tools):
OptiX OSN 6800 V100R004 C04 SPC800(5.51.05.35)Software
DataCenter Client
wftpd32
Navigator

Passo a passo:
1- Descompactar os arquivos no C:
2- Instalar o Data Center no C:
3- Abrir o Data Center Client, Navigator, wftp32
4- Criar uma pasta com o NOME ou ID do Equipamento a ser atualizado.
5- No WFTP ir no menu Security, User/rights, New User. Criar user and password. Em Home Directory copiar o diretorio da pasta criada
6- Abrir o navigator e rodar os seguintes comandos em bold:
:ver
:sftm-get-freespace:bid,"cfs1" //checar espao livre na memoria, maior q 30M. bid(slot da SCC, colocar 18 ou 17)

:sftm-rtrv-state:swdl
//checar status do NE.
Exemplo:
SFTM_RTVE_STATE
CPY_TYPE
MAIN_STATE
SUB_STATE
swdl
NORMAL(CPY_FILE_END)
NORMAL
Total records :1
// precisar estar NORMAL para rodar o upgrade!!!

:cfg-verify
:cfg-get-nestate // precisar estar running.

7- No Data Center, ir no menu Data Center, Options, System Setting. No campo Server IP Address colocar o IP de seu comp
4. Colocar o User Name e o Passoword em Configure FTP e clicar em Test FTP e depois OK no final da janela.
8- Criar o Pacote de Software a ser carregado que est no C:\OptiX OSN 6800 V100R004 C04 SPC800(5.51.05.35)Software\SWDL\SWDL_68&8
Navigator. Digitar Y (yes) e ENTER.
9- No menu Data Center, Software Archive Management, clicar com o boto direito na rea cinza e clicar em Import. Escolher o
8. Arquivo 68_88.pkg. Click em OK.
10- Na aba Device Management, clicar com o boto direito na parte cinza, Device Management, Add Device. Na coluna do lado
eqpto), click OK.
11- No menu click em Data Center, Task Management. Boto direito na parte cinza, New Task, Package Upgrade Task..., do
Clicar em Next. Em Target Version selecionar nossa verso. OK. Next. OK.
12- Boto direito na nossa Task. Start Task. A cada tafera terminada, o processo pausado e necessita de um START para iniciar a prx

o diretorio da pasta criada no passo 4. Ex.: C:\SAM. Depois clicar em DONE


ou 17)

colocar o IP de seu computador. Na aba File Transfer Service Setting e no campo File Transfer Service Root Directory colocar o diretorio da
ela.
ftware\SWDL\SWDL_68&88_C02\SWDL. Dentre esses 280 arquivos achar o Make pkg file e dois cliques, digitar a opo que condiz com o software pr

em Import. Escolher o modelo do equipamento em Device Type, Software Package em File Type. No campo Path escolher o software atravs

evice. Na coluna do lado esquerdo da janela escolher nosso equipamento + Optix OSN 6800/Optix OSN 6800. Do lado direito colocar o ID (750), Extende

ge Upgrade Task..., do lado esquerdo na opo Device Version escolher a verso atual (5.51.05.26). Selecionar o equipamento na opo abaixo
START para iniciar a prxima tarefa. Por exemplo Pre-Check, Backup, Load Software, Dispense, etc...

ry colocar o diretorio da mesma pasta criada no passo


condiz com o software presente na SCC visto pelo

scolher o software atravs do mesmo caminho do passo

olocar o ID (750), Extende ID (9), Gateway Address (ip

amento na opo abaixo e checar se esta do lado direito.