8 p350[0] M Motor stator 0.46430 0.59632 Ohm
resistance, cold
resistance cold
10 p356[0] M Motor stator 5.21441 4.90351 mH
C leakage C
inductance
11 p358[0] M Motor rotor 5.60251 5.13916 mH
leakage
inductance
12 p360[0] M Motor 75.27529 106.94038 mH
magnetizing
inductance
13 p601[0] M Motor [1] PTC alarm timer [0] No sensor
temperature
sensor type
14 p610[0] M Motor [2] Alarm and fault no reduction of I_max [1] Alarm with reduction of I_max
D overtemperatur and fault D
e response
15 p622[0] M Motor excitation 0.288 0.326 s
time for
Rs_ident after
powering up
again
16 p640[0] D Current limit 21.75 22.65 Arms
17 p703 Pre-assignmen
t digital input 2
18 p703[0] C Pre-assignmen [0] No pre-assignment [9] 2. Acknowledge faults
t digital input 2
E 19 p704 Pre-assignmen E
t digital input 3
20 p704[0] C Pre-assignmen [0] No pre-assignment [15] Fixed speed setpoint
t digital input 3 selection Bit 0
21 p705 Pre-assignmen
t digital input 4
22 p705[0] C Pre-assignmen [0] No pre-assignment [16] Fixed speed setpoint
t digital input 4 selection Bit 1
23 p706 Pre-assignmen
t digital input 5
24 p706[0] C Pre-assignmen [0] No pre-assignment [17] Fixed speed setpoint
t digital input 5 selection Bit 2
F F
Date 31/05/2017
Editor
Checked
State Modification Date Name Standard
Page 1
Pg. 5
1 2 3 4
1 2 3 4
Parameter Data Parameter text "16-T1_DOFFER_ROLL_EFO".Control_Unit Online - Unit
set "16-T1_DOFFER_ROLL_EFO".C
ontrol_Unit
25 p922 PROFIdrive [999] Free telegram configuration with BICO [1] Standard telegram 1, PZD-2/2
telegram
selection
selection Bit 1
contents is not permitted without express written authority.
F F
Date 31/05/2017
Editor
Checked
State Modification Date Name Standard
Page 2
Pg. 5
1 2 3 4
1 2 3 4
Parameter Data Parameter text "16-T1_DOFFER_ROLL_EFO".Control_Unit Online - Unit
set "16-T1_DOFFER_ROLL_EFO".C
ontrol_Unit
45 p1249[0] D Vdc_max 17.60 14.55 rpm
controller speed
threshold
A A
46 p1280[0] D Vdc controller or [0] Inhib Vdc ctrl [1] Vdc_max controller enable
Vdc monitoring
configuration
(V/f)
Page 3
Pg. 5
1 2 3 4
1 2 3 4
Parameter Data Parameter text "16-T1_DOFFER_ROLL_EFO".Control_Unit Online - Unit
set "16-T1_DOFFER_ROLL_EFO".C
ontrol_Unit
64 p1755[0] D Motor model 120.00 100.00 rpm
changeover
speed
encoderless
A operation A
identification
created by patent grant or registration or a utility model or
PEM
encoderless
70 p2000 Reference speed 1800.00 1500.00 rpm
reference
frequency
sdesign, are reserved.
Page 4
Pg. 5
1 2 3 4
1 2 3 4
Parameter Data Parameter text "16-T1_DOFFER_ROLL_EFO".Control_Unit Online - Unit
set "16-T1_DOFFER_ROLL_EFO".C
ontrol_Unit
90 p2161[0] D Speed threshold 108.00 90.00 rpm
3
91 p2162[0] D Hysteresis 176.00 145.50 rpm
A speed n_act > A
n_max
92 p2163[0] D Speed threshold 180.00 150.00 rpm
4
93 p2164[0] D Hysteresis 18.00 15.00 rpm
speed 4
94 p2170[0] D Current 14.50 15.10 Arms
threshold value
95 p2175[0] D Motor locked 36.00 30.00 rpm
speed threshold
controller fixed
value selection
bit 0
99 p2220[0] C BI: Technology 0 Control_Unit : r722.3
controller fixed
value selection
bit 0
sdesign, are reserved.