ANEXO 1

VRG LINHAS AÉREAS S.A.


CHETA 2006-12-0VRN-01-00
CHE 0411-01/ANAC
DTE – DISPOSIÇÃO TÉCNICA DE ENGENHARIA Nº: MN- 128512

(ETD – ENGINEERING TECHNICAL DISPOSITION) DATA: 25/08/2014


CHE 0411-01/ANAC
CHETA 2006-12-0VRN-01-00

ACFT: Toda Frota GOL


FROTA: Toda frota 737
ATA: 28-10

ASSUNTO: Refuel Valve Indicator Light inoperante


SOLICITANTE: Coordenadoria de Controle de Frota
VIA: ‫ ܈‬TA ‫ ܆‬E-mail--------- ‫ ܈‬Reunião
‫ ܈‬Outra (Especifique): T/A 128512
DATA DA SOLICITAÇÃO: 19/08/2014
TEMPO DE RESPOSTA: 5 dias
H/H GASTO: Engenharia: 03h40min
Outros (Especifique): N/A
REFERÊNCIAS: SR#42641782272

DISCREPÂNCIA REPORTADA:
Durante atendimento rotineiro de transito, a manutenção observou o não acendimento da Refuel
Valve Indicator Light ao se posicionar a switch para a posição open durante o inicio do
abastecimento da aeronave. Esta switch está localizada no painel de abastecimento da asa,
conforme imagem de referencia abaixo:

FORM-IT/MM-MS-019-03 R00
DTE – DIS
SPOSIÇÃO
O TÉCNIC
CA DE ENG
GENHARIA
A Nº: MN-
M 128512
2

(
(ETD – EN
NGINEERIN
NG TECHN
NICAL DIS
SPOSITIO
ON) DAT
TA: 25/08/2014
CHE 0411-01/ANA
AC
CHETA 2006-12-0VRN-01-00

O painel de
e abastecim
mento na as
sa da aeron
nave somen
nte é acessa
ado durantee atendimento de solo e
acordo Manual de Ma
anutenção 28-21-00
2 pa
arte I, a função das trê
ês luzes ind icadoras é mostrar para
o abasteced
o mecânico dor que cad
da válvula d
de abastecimento está energizadaa e pronta para
p liberarr a
entrada do
o combustíível para os
o respectivvos tanque
es. As refe
eridas três luzes indicadoras nã
ão
mostram q
que as válvvulas de ab
bastecimentto estão ab
bertas ou fe
echadas. N
Não foi encontrada um
ma
referencia para despa
acho da aero
onave com alguma dessas três lu
uzes indicaddoras apaga
adas.

DISPOSIÇÃ
ÃO DA ENGENHARIA
A:
A Engenha
aria de Sisstemas Me
ecânicos co
oncluiu que
e a aerona
avegabilidadde da aero
onave não é
afetada ca
aso alguma das três luzes indica
adoras do painel de abastecime
a ento estejam
m apagada
as.
Mesmo asssim, esta Engenharia submeteu
s u
um question
namento ao
o fabricante das aerona
aves da fro
ota
do SR 4-264
GOL acord 41782272 anexo
a eaB
Boeing conc
corda com a nossa possição e não tem objeçã
ão
técnica para limitar a operação da aeronavve até o re
eparo ou su
ubstituição da lâmpad
da indicadora
desde que
e a manute
enção verifiq
que que a válvula es
steja operan
ndo normallmente e que
q antes do
d
fechamento
o do painel de abastec
cimento, cerrtifique-se que
q a respe
ectiva válvulla esteja fec
chada.
Com base nisso, esta
a Engenharria autoriza
a a operaçã
ão da aeron
nave com a Refuel Va
alve Indicattor
erante por 120 dias, até
Light inope é que seja ffeito o reparo ou substituição das lâmpadas indicadoras
i s.


Elaborado
E p
por: Henriq
que Ferreira
a de Souza Apro
ovado por: Peterson G.
G Bernardo
o
CIF:
C 8844 CIF: 4139

FORM-IT//MM-MS-019
9-03 R00
Praça Comandante Linneu Gomes,
S/N, Portaria 03 - SAOMM
Congonhas - São Paulo – SP
Cep: 04626-020
Telefone: (11) 5098-2312
Fax: (11) 5098-2552

ANEXO 2

VRG LINHAS AÉREAS S.A.


CHETA 2006-12-0VRN-01-00
CHE 0411-01/ANAC
-------------------------------------------------------------------------------------------------- Page 4 of 6 ----

Email Message related to Service Request Customer Name: GOL Airlines


Number: 4-2641782272

Owner: Gary Morriss Message Sent: 22-Aug-2014 06:54:04 PM ((GMT-


03:00) Brasilia)

Message Number: GOT-GOT-14-0374-02B Communication Status: Done

Communication Type: Boeing Response

From: Due:

Field Base:

To: hfdesouza@golnaweb.com.br,gr-
engenhariadesistemasmecanicos@golnaweb.com.br,fpinto@golnaweb.com.br

Cc:

Airplanes:

Registry Number Variable Number Serial Number Hours Cycles

Inquiry Type: Fleet Wide Request/Other

FAA Form 8100-9 Requested: No Repair and Deviation Record Requested: No

Subject: Refueling valve indicator light

Body:

FROM: THE BOEING COMPANY


TO: GOL Airlines (GOT)
[MESSAGE NUMBER:GOT-GOT-14-0374-02B] Boeing Response
MESSAGE DATE: 22 Aug 2014 1453 US PACIFIC TIME / 22 Aug 2014 2153 GMT

The following message is distributed to the following people at GOL Airlines:


Henrique Ferreira Souza, Systems Engineering GROUP, Fabio Pinto

Service Category: Airplane Model: 737Series/Product: 737-800 ATA: 2810-00

SUBJECT: Refueling valve indicator light

INQUIRY TYPE: Other FAA Form 8100-9 Requested: No Repair Design Record Requested: No

REFERENCES:
/A/ 65-0028-11 - light test
-------------------------------------------------------------------------------------------------- Page 5 of 6 ----

/B/ MEL 28-10-02 CAT "C"


/C/ GOT-GOT-14-0374-01C
/D/ AMM task 12-11-00-650-806: Pressure Refueling Operation For A Refuel Valve That Does Not Open
Electr
/E/ 737-SL-28-090

DESCRIPTION:

In the ref /C/ message GOL Airlines (GOT) reported they have received reports from maintenance staff about
refueling valve indicator light ref /A/ failure.

GOT believes that the defect is only a light indication problem and the aircraft can be released to service.
However, GOT does not have a proper MEL item to support reference.
Note that Ref /B/ MEL is regarding the Re-fueling system and do not mention the Ref/A/ light test.

Desired Action
======================
GOT would like to know if Boeing has a technical objection to continue revenue operation of aircraft without ref
/A/ installed or failure until it can be replace.

RESPONSE:

The 344A2801-2 refueling panel on the datum airplane contains (3) ref /A/ indicator lights, each indicating if
the respective fueling shutoff valve has power to open. The refueling panel, its valves, and the indicator lights
are typically only used during ground refueling operations, and cannot be accessed in flight.

As GOL Airlines notes there is no specific MEL item that addresses the ref /A/ light, however, the ref /B/ MEL
item does provide relief for an inoperative fueling shutoff valve.

Provided the operator verifies the valve(s) with the defective ref /A/ indicator operates and is verified closed
each time just prior to closing the refueling panel, Boeing has no technical objection, (NTO), to continue
revenue operation until the ref /A/ indicator is repaired or replaced. If the valve(s) can not be operated
electrically the ref /D/ AMM procedure can be used.

Depending on the failure mode of the refuel valve indicator light, the ref /E/ service letter may be beneficial in
addressing the failed light.

If attachments are referred to, and are not present, please access them by logging into MyBoeingFleet Service
Requests application or contact your Boeing Field Service Representative.
-------------------------------------------------------------------------------------------------- Page 6 of 6 ----

https://myboeingfleet.boeing.com/servicerequests/index.html?entityId=4-
17OZIZP&entityType=CommunicationMessage
Suppliers, please access attachments by logging into Boeing Partner Network Supplier Service Requests
application.

Gary Morriss Propulsion Systems - Seattle


Glenn Primavera
Commercial Aviation Services
The Boeing Company

Você também pode gostar