Você está na página 1de 1

KEYPLAN

R U C TION
C O NST RUÇÃO
E D FOR CONST
ISSU O PARA
ID
EMIT

00 ISSUED FOR CONSTRUCTION C.B. M.G. 23-10-18


EMITIDO PARA CONSTRUÇÃO
REV DESCRIPTION / DESCRIÇÃO BY ENG DATE/DATA
POR

3D VIEW DESIGN/PROJETO: A. MOHAMED 22-02-08


VISUALIZAÇÃO 3D DRAWN/DESENHO: C. BOUDREAU 22-02-08
CHECKED/VERIFICADO: V. ACIMOVIC 22-02-08
NOTES: NOTAS: ENGINEER/ENGENHEIRO: M. GERACE 22-02-08
1. FOR STEEL GENERAL NOTES AND STANDARD DETAILS SEE DWGS. BRTZ-1-001-ST-STD-0001 TO BRTZ-1-001-ST-STD-0010. 1. PARA NOTAS GERAIS E DETALHES PADRÃO DO AÇO, VER DESENHOS BRTZ-1-001-ST-STD-0001 A BRTZ-1-001-ST-STD-0010
SCALE/ESCALA: DATE/
DATADO
1.1 REFER TO GENERAL SITE PLANT DRAWING BRTZ-1-600-GE-GA-0001 FOR GENERAL PLANT POSITION AND WORKPOINT. 1.1 CONSULTE O DESENHO GERAL DA PLANTA BRTZ-1-600-GE-GA-0001 PARA A POSIÇÃO GERAL DA PLANTA E PONTO DE TRABALHO.

1.2 REFER TO BRTZ-1-663-ST-3DM-0001 FOR 3D STRUCTURE MODEL 1.2 CONSULTE BRTZ-1-663-ST-3DM-0001 PARA MODELO DE ESTRUTURA 3D
TOCANTINZINHO
2. ALL DIMENSIONS ARE IN MILLIMETERS AND ELEVATIONS ARE INE METERS UNLESS NOTED OTHERWISE. 2. TODAS AS DIMENSÕES ESTÃO EM MILÍMETROS E AS ELEVAÇÕES ESTÃO EM METROS, A MENOS QUE INDICADO DE OUTRA FORMA.
PHASE / FASE:
3. CONNECTIONS: 3. LIGAÇÕES: DETAIL ENGINEERING
3.1 BEAMS CONNECTIONS SHALL BE DESIGNED FOR REACTIONS PRODUCED BY 125% OF THE UNIFORM LOAD CAPACITIES INDICATED IN THE 3.1. AS LIGAÇÕES DA VIGA DEVEM SER PROJETADAS PARA REAÇÕES PRODUZIDAS ATÉ 125% DAS CAPACIDADES DE CARGA UNIFORMES ENGENHARIA DE DETALHE
BEAM LOAD TABLES, CISC HANDBOOK OF STEEL CONSTRUCTION (LATEST EDITION) OR 60% OF THE SHEAR CAPACITY OF THE MEMBER, INDICADAS NAS TABELAS DE CARGA DE VIGA, AISC MANUAL DE CONSTRUÇÃO EM AÇO (ÚLTIMA EDIÇÃO) OU 60% DA CAPACIDADE AO
WHICHEVER IS GREATER. DO NOT EXCEED SHEAR CAPACITES OF BEAMS. ALL FIELD CONNECTIONS SHALL BE BOLTED, EXCEPT FULL CISALHAMENTO DO MEMBRO, OU QUAL FOR MAIOR. NÃO EXCEDA AS CAPACIDADES AO CISALHAMENTO DAS VIGAS. TODAS AS LIGAÇÕES TITLE:
STRENGTH CONNECTIONS. WHEN REACTIONS ARE SHOWN ON THE DRAWING, THE CONNECTIONS SHALL BE DESIGNED DE CAMPO DEVEM SER PARAFUSADAS, EXCETO AS LIGAÇÕES DE RESISTÊNCIA TOTAL. QUANDO AS REAÇÕES FOSSEM MOSTRADAS NO GOLDROOM
ACCORDINGLY, INCLUDING AXIAL FORCES. DESENHO, AS LIGAÇÕES DEVEM SER PROJETADAS RESPECTIVAMENTE, INCLUINDO FORÇAS AXIAIS.
STRUCTURAL
3.2 BRACING TO BE DESIGNED FOR THE HIGHER VALUE OF: a OR b. 3.2. O CONTRAVENTAMENTO SERÁ PROJETADO PARA O MAIOR VALOR DE: a OU b. 3D MODEL
a: 50% OF THE EFFECTIVE MEMBER CAPACITY IN TENSION OR COMPRESSION. a: 50% DA CAPACIDADE EFETIVA DO MEMBRO EM TRAÇÃO OU COMPRESSÃO.
b: FORCES INDICATED ON THE DRAWINGS. b: FORÇAS INDICADAS NOS DESENHOS.
2023-10-18 10:49:53

3.3 FRAMING AROUND OPENINGS IN THE ROOF AND FLOORS MAY BE WELDED ON SITE WITH THE ENGINEER'S CONSENT. 3.3. A ESTRUTURA EM VOLTA DAS ABERTURAS NA COBERTURA E NO PISO PODE SER SOLDADA EM CAMPO COM O CONSENTIMENTO DO
TÍTULO:
ENGENHEIRO. QUARTO OURO
4. COLUMN SPLICES SHALL BE DESIGNED FOR 100% OF THE MEMBERS CAPACITY IN BENDING, SHEAR AND AXIAL COMPRESSION. THE (2)
FACES OF THE SPLICES SHALL BE IN CONTACT ALL OVER THEIR SURFACES. 4. AS EMENDAS DE COLUNA DEVEM SER PROJETADAS PARA 100% DA CAPACIDADE DOS MEMBROS EM FLEXÃO, CISALHAMENTO E COMPRESSÃO AXIAL.
ESTRUTURA
AS (2) FACES DAS EMENDAS DEVEM ESTAR EM CONTATO EM TODAS SUAS SUPERFÍCIES. MODELO 3D
5. EACH END OF PANEL OR OPENINGS IN GRATING PANELS SHALL BE FRAMED ALL AROUND WITH BAR OF SAME DIMENSIOSN AS THE
Printed on:

BEARING BAR OF THE GRATING. 5. CADA EXTREMIDADE DO PAINEL OU ABERTURAS NA GRADE DE PISO DEVEM SER EMOLDURADAS TUDO EM VOLTA COM BARRAS DAS MESMAS

6. MINIMUM BEARING SUPPORT FOR GRATING SHALL BE 40mm.


DIMENSÕES DA BARRA PORTANTE DA GRADE DE PISO.
0 1 2 3 4 5 10
DRAWING NO./ Nº DESENHO: BRTZ-1
: A1

6. AS BARRAS DE SOPORTE PARA A GRADE DE PISO DEVEM SER DE 40mm NO MÍNIMO. PROJ. NO.
7. HOLES OTHER THAN THOSE SHOWN ON THE DRAWINGS ARE NOT PERMITTED UNLESS APPROVED IN WRITING BY THE ENGINEER.
7. OUTROS FUROS ALÉM DOS MOSTRADOS NOS DESENHOS NÃO SÃO PERMITIDOS A MENOS QUE APROVADOS POR ESCRITO PELO ENGENHEIRO. GRAPHIC SCALE: 1:100 663 ST DWG 0001 00
AREA/SECTOR DISC. TYPE/TIPO SEQ./SECUENTIAL REV.
SIZE
SHEET