Programaes de Automao Biotcnica

HITACHI 902

ESTE MARCA REGISTRADA DE SEUS FABRICANTES.

REVISO 00 - MAI/2006

SAC BioTcnica Ind e Com. Ltda.


Tel / Fax: +55 35 3214-4646 Varginha MG Brasil.
Site: www.biotecnica.ind.br / e-mail: sac@biotecnicaltda.com.br

Programaes de Automao Biotcnica


HITACHI 902
Indice
CIDO RICO BI
ACIDO RICO MONO
ALBUMINA
-AMILASE
ALT/TGP
AST/TGO
CLCIO ASX
CLCIO
CK NAC
CK MB
COLESTEROL
CREATININA
DESIDROGENASE LACTICA
FERRO CRX
FERRO FEZ
FOSFATASE ALCALINA
FSFORO UV
GAMA GT
GLICOSE
HDL COLESTEROL
HDL COLESTEROL DIRETO
LDL COLESTEROL
MAGNSIO
PROTENAS TOTAIS
TRIGLICERIDES
URIA UV
PROTENAS URINRIA

3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29

ESTE MARCA REGISTRADA DE SEUS FABRICANTES.

REVISO 00 - MAI/2006

SAC BioTcnica Ind e Com. Ltda.


Tel / Fax: +55 35 3214-4646 Varginha MG Brasil.
Site: www.biotecnica.ind.br / e-mail: sac@biotecnicaltda.com.br

Programaes de Automao Biotcnica


HITACHI 902
PRODUTO
CATLOGO
METODOLOGIA
N DETERMINAES

CIDO RICO-BI
BT 10.014.00
ENZIMTICO
COLORIMTRICO
1000

- O nmero de determinaes foi calculado


desconsiderando o volume morto do frasco de
reagente do equipamento.
- Recomenda-se a leitura das Instrues de Uso
(I.U) antes da utilizao do produto.
As informaes complementares para realizao do
teste esto descritas no Protocolo de Automao
ao lado:
PREPARAO DOS REAGENTES
R1: Reagente A - Pronto para uso
R3: Reagente B - Pronto para uso
CALIBRADORES
CONTROLES
Para avaliar o
desempenho do teste,
sugere-se a utilizao dos
controles Biotcnica:
Autocal H
CAT BT 13.002.00
- Quantinorm
CAT BT 13.003.00
- Quantialt
CAT BT 13.004.00
OBSERVAES ESPECIAIS
No Aplicvel

@ Inserir a concentrao indicada no calibrador


Biotcnica Autocal H
* Parmetro definido pelo usurio

ESTE MARCA REGISTRADA DE SEUS FABRICANTES.

NO.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58

TEST
TEST NAME
ASSAY CODE (METHOD)
ASSAY CODE (TEST)
REACTION TIME
ASSAY POINT 1
ASSAY POINT 2
ASSAY POINT 3
ASSAY POINT 4
WAVELENGHT (SUB)
WAVELENGHT (MAIN)
SAMPLE VOLUME
R1 VOLUME
R1 POSITION
R1 BOTTLE SIZE
R2 VOLUME
R2 POSITION
R2 BOTTLE SIZE
R3 VOLUME
R3 POSITION
R3 BOTTLE SIZE
CALIBRATION TYPE (TYPE)
CALIBRATION TYPE (WIGHT)
CALIBRATOR CONC. 1
CALIBRATOR POSITION 1
CALIBRATOR CONC. 2
CALIBRATOR POSITION 2
CALIBRATOR CONC. 3
CALIBRATOR POSITION 3
CALIBRATOR CONC. 4
CALIBRATOR POSITION 4
CALIBRATOR CONC. 5
CALIBRATOR POSITION 5
CALIBRATOR CONC. 6
CALIBRATOR POSITION 6
S1 ABS
K FACTOR
K 2 FACTOR
K 2 FACTOR
K 4 FACTOR
K 5 FACTOR
A FACTOR
B FACTOR
C FACTOR
SD LIMIT
DUPLICATE LIMIT
SENS.MLIMIT
S1 ABS LIMIT (L)
S1 ABS LIMIT (H)
ABS LIMIT
ABS LIMIT (D/I)
PRZ LIMIT
PRZ LIMIT (U/D)
PRZ (END POINT)
EXPECT. VALUE (L)
EXPECT. VALUE (H)
INSTR. FACTOR (A)
INSTR. FACTOR (B)
KEY SETTING

DESCRIPTION
ACU
2 POINT END
0
10
17
35
0
0
660
505
5
200
*
*
0
0
0
50
*
*
LINEAR
0
0.00
*
@
*
0
0
0
0
0
0
0
0
0
10000
10000
10000
10000
10000
0
0
0
0.1
100
32000
-32000
32000
0
1
32000
U
35
*
*
1.0

0.0
POS. TECLADO

REVISO 00 - MAI/2006

SAC BioTcnica Ind e Com. Ltda.


Tel / Fax: +55 35 3214-4646 Varginha MG Brasil.
Site: www.biotecnica.ind.br / e-mail: sac@biotecnicaltda.com.br

Programaes de Automao Biotcnica


HITACHI 902
PRODUTO
CATLOGO
METODOLOGIA
N DETERMINAES

CIDO RICO-MONO
BT 10.001.00
ENZIMTICO
COLORIMTRICO
833

- O nmero de determinaes foi calculado


desconsiderando o volume morto do frasco de
reagente do equipamento.
- Recomenda-se a leitura das Instrues de Uso
(I.U) antes da utilizao do produto.
As informaes complementares para realizao do
teste esto descritas no Protocolo de Automao
ao lado:
PREPARAO DOS REAGENTES
R1: Reagente - Pronto para uso
CALIBRADORES
CONTROLES
Para avaliar o
desempenho do teste,
sugere-se a utilizao dos
controles Biotcnica:
Autocal H
CAT BT 13.002.00
- Quantinorm
CAT BT 13.003.00
- Quantialt
CAT BT 13.004.00
OBSERVAES ESPECIAIS
No Aplicvel

@ Inserir a concentrao indicada no calibrador


Biotcnica Autocal H
* Parmetro definido pelo usurio

ESTE MARCA REGISTRADA DE SEUS FABRICANTES.

NO.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58

TEST
TEST NAME
ASSAY CODE (METHOD)
ASSAY CODE (TEST)
REACTION TIME
ASSAY POINT 1
ASSAY POINT 2
ASSAY POINT 3
ASSAY POINT 4
WAVELENGHT (SUB)
WAVELENGHT (MAIN)
SAMPLE VOLUME
R1 VOLUME
R1 POSITION
R1 BOTTLE SIZE
R2 VOLUME
R2 POSITION
R2 BOTTLE SIZE
R3 VOLUME
R3 POSITION
R3 BOTTLE SIZE
CALIBRATION TYPE (TYPE)
CALIBRATION TYPE (WIGHT)
CALIBRATOR CONC. 1
CALIBRATOR POSITION 1
CALIBRATOR CONC. 2
CALIBRATOR POSITION 2
CALIBRATOR CONC. 3
CALIBRATOR POSITION 3
CALIBRATOR CONC. 4
CALIBRATOR POSITION 4
CALIBRATOR CONC. 5
CALIBRATOR POSITION 5
CALIBRATOR CONC. 6
CALIBRATOR POSITION 6
S1 ABS
K FACTOR
K 2 FACTOR
K 2 FACTOR
K 4 FACTOR
K 5 FACTOR
A FACTOR
B FACTOR
C FACTOR
SD LIMIT
DUPLICATE LIMIT
SENS.MLIMIT
S1 ABS LIMIT (L)
S1 ABS LIMIT (H)
ABS LIMIT
ABS LIMIT (D/I)
PRZ LIMIT
PRZ LIMIT (U/D)
PRZ (END POINT)
EXPECT. VALUE (L)
EXPECT. VALUE (H)
INSTR. FACTOR (A)
INSTR. FACTOR (B)
KEY SETTING

DESCRIPTION
ACU
1 POINT
0
10
35
0
0
0
660
505
6.0
300
*
*
0
0
0
0
0
0
LINEAR
0
0.00
*
@
*
0
0
0
0
0
0
0
0
0
10000
10000
10000
10000
10000
0
0
0
0.1
100
32000
-32000
32000
0
1
32000
U
35
*
*
1.0

0.0
POS. TECLADO

REVISO 00 - MAI/2006

SAC BioTcnica Ind e Com. Ltda.


Tel / Fax: +55 35 3214-4646 Varginha MG Brasil.
Site: www.biotecnica.ind.br / e-mail: sac@biotecnicaltda.com.br

Programaes de Automao Biotcnica


HITACHI 902
PRODUTO
CATLOGO
METODOLOGIA
N DETERMINAES

ALBUMINA
BT 10.002.00
COLORIMTRICO
833

- O nmero de determinaes foi calculado


desconsiderando o volume morto do frasco de
reagente do equipamento.
- Recomenda-se a leitura das Instrues de Uso
(I.U) antes da utilizao do produto.
As informaes complementares para realizao do
teste esto descritas no Protocolo de Automao
ao lado:
PREPARAO DOS REAGENTES
R1: Reagente de Cor - Pronto para uso
CALIBRADORES
CONTROLES
Para avaliar o
desempenho do teste,
sugere-se a utilizao dos
controles Biotcnica:
Autocal H
CAT BT 13.002.00
- Quantinorm
CAT BT 13.003.00
- Quantialt
CAT BT 13.004.00
OBSERVAES ESPECIAIS
No Aplicvel

@ Inserir a concentrao indicada no calibrador


Biotcnica Autocal H
* Parmetro definido pelo usurio

ESTE MARCA REGISTRADA DE SEUS FABRICANTES.

NO.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58

TEST
TEST NAME
ASSAY CODE (METHOD)
ASSAY CODE (TEST)
REACTION TIME
ASSAY POINT 1
ASSAY POINT 2
ASSAY POINT 3
ASSAY POINT 4
WAVELENGHT (SUB)
WAVELENGHT (MAIN)
SAMPLE VOLUME
R1 VOLUME
R1 POSITION
R1 BOTTLE SIZE
R2 VOLUME
R2 POSITION
R2 BOTTLE SIZE
R3 VOLUME
R3 POSITION
R3 BOTTLE SIZE
CALIBRATION TYPE (TYPE)
CALIBRATION TYPE (WIGHT)
CALIBRATOR CONC. 1
CALIBRATOR POSITION 1
CALIBRATOR CONC. 2
CALIBRATOR POSITION 2
CALIBRATOR CONC. 3
CALIBRATOR POSITION 3
CALIBRATOR CONC. 4
CALIBRATOR POSITION 4
CALIBRATOR CONC. 5
CALIBRATOR POSITION 5
CALIBRATOR CONC. 6
CALIBRATOR POSITION 6
S1 ABS
K FACTOR
K 2 FACTOR
K 2 FACTOR
K 4 FACTOR
K 5 FACTOR
A FACTOR
B FACTOR
C FACTOR
SD LIMIT
DUPLICATE LIMIT
SENS.MLIMIT
S1 ABS LIMIT (L)
S1 ABS LIMIT (H)
ABS LIMIT
ABS LIMIT (D/I)
PRZ LIMIT
PRZ LIMIT (U/D)
PRZ (END POINT)
EXPECT. VALUE (L)
EXPECT. VALUE (H)
INSTR. FACTOR (A)
INSTR. FACTOR (B)
KEY SETTING

DESCRIPTION
ALB
1 POINT
0
3
8
0
0
0
700
600
3.0
300
*
*
0
0
0
0
0
0
LINEAR
0
0.00
*
@
*
0
0
0
0
0
0
0
0
0
10000
10000
10000
10000
10000
0
0
0
0.1
100
32000
-32000
32000
0
1
32000
U
35
*
*
1.0

0.0
POS. TECLADO

REVISO 00 - MAI/2006

SAC BioTcnica Ind e Com. Ltda.


Tel / Fax: +55 35 3214-4646 Varginha MG Brasil.
Site: www.biotecnica.ind.br / e-mail: sac@biotecnicaltda.com.br

Programaes de Automao Biotcnica


HITACHI 902
PRODUTO
CATLOGO
METODOLOGIA
N DETERMINAES

-AMILASE
BT 11.001.00
CINTICO
COLORIMTRICO
200

- O nmero de determinaes foi calculado


desconsiderando o volume morto do frasco de
reagente do equipamento.
- Recomenda-se a leitura das Instrues de Uso
(I.U) antes da utilizao do produto.
As informaes complementares para realizao do
teste esto descritas no Protocolo de Automao
ao lado:
PREPARAO DOS REAGENTES
R1: Reagente - Pronto para uso
CALIBRADORES
CONTROLES
Para avaliar o
desempenho do teste,
sugere-se a utilizao dos
controles Biotcnica:
Autocal H
CAT BT 13.002.00
- Quantinorm
CAT BT 13.003.00
- Quantialt
CAT BT 13.004.00
OBSERVAES ESPECIAIS
No Aplicvel

@ Inserir a concentrao indicada no calibrador


Biotcnica Autocal H
* Parmetro definido pelo usurio

ESTE MARCA REGISTRADA DE SEUS FABRICANTES.

NO.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58

TEST
TEST NAME
ASSAY CODE (METHOD)
ASSAY CODE (TEST)
REACTION TIME
ASSAY POINT 1
ASSAY POINT 2
ASSAY POINT 3
ASSAY POINT 4
WAVELENGHT (SUB)
WAVELENGHT (MAIN)
SAMPLE VOLUME
R1 VOLUME
R1 POSITION
R1 BOTTLE SIZE
R2 VOLUME
R2 POSITION
R2 BOTTLE SIZE
R3 VOLUME
R3 POSITION
R3 BOTTLE SIZE
CALIBRATION TYPE (TYPE)
CALIBRATION TYPE (WIGHT)
CALIBRATOR CONC. 1
CALIBRATOR POSITION 1
CALIBRATOR CONC. 2
CALIBRATOR POSITION 2
CALIBRATOR CONC. 3
CALIBRATOR POSITION 3
CALIBRATOR CONC. 4
CALIBRATOR POSITION 4
CALIBRATOR CONC. 5
CALIBRATOR POSITION 5
CALIBRATOR CONC. 6
CALIBRATOR POSITION 6
S1 ABS
K FACTOR
K 2 FACTOR
K 2 FACTOR
K 4 FACTOR
K 5 FACTOR
A FACTOR
B FACTOR
C FACTOR
SD LIMIT
DUPLICATE LIMIT
SENS.MLIMIT
S1 ABS LIMIT (L)
S1 ABS LIMIT (H)
ABS LIMIT
ABS LIMIT (D/I)
PRZ LIMIT
PRZ LIMIT (U/D)
PRZ (END POINT)
EXPECT. VALUE (L)
EXPECT. VALUE (H)
INSTR. FACTOR (A)
INSTR. FACTOR (B)
KEY SETTING

DESCRIPTION
AMI
RATE A
0
5
5
18
0
0
700
415
6.0
300
*
*
0
0
0
0
0
0
LINEAR
0
0.00
*
@
*
0
0
0
0
0
0
0
0
0
10000
10000
10000
10000
10000
0
0
0
0.1
100
32000
-32000
32000
0
1
32000
U
35
*
*
1.0

0.0
POS. TECLADO

REVISO 00 - MAI/2006

SAC BioTcnica Ind e Com. Ltda.


Tel / Fax: +55 35 3214-4646 Varginha MG Brasil.
Site: www.biotecnica.ind.br / e-mail: sac@biotecnicaltda.com.br

Programaes de Automao Biotcnica


HITACHI 902
PRODUTO
CATLOGO
METODOLOGIA
N DETERMINAES

ALT/TGP
BT 11.008.00
CINTICO UV
833

- O nmero de determinaes foi calculado


desconsiderando o volume morto do frasco de
reagente do equipamento.
- Recomenda-se a leitura das Instrues de Uso
(I.U) antes da utilizao do produto.
As informaes complementares para realizao do
teste esto descritas no Protocolo de Automao
ao lado:
PREPARAO DOS REAGENTES
R1: Reagente A - Pronto para uso
R3: Reagente B - Pronto para uso
CALIBRADORES
CONTROLES
Para avaliar o
desempenho do teste,
sugere-se a utilizao dos
controles Biotcnica:
Autocal H
CAT BT 13.002.00
- Quantinorm
CAT BT 13.003.00
- Quantialt
CAT BT 13.004.00
OBSERVAES ESPECIAIS
No Aplicvel
@ Inserir a concentrao indicada no calibrador
Biotcnica Autocal H
* Parmetro definido pelo usurio

ESTE MARCA REGISTRADA DE SEUS FABRICANTES.

NO.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58

TEST
TEST NAME
ASSAY CODE (METHOD)
ASSAY CODE (TEST)
REACTION TIME
ASSAY POINT 1
ASSAY POINT 2
ASSAY POINT 3
ASSAY POINT 4
WAVELENGHT (SUB)
WAVELENGHT (MAIN)
SAMPLE VOLUME
R1 VOLUME
R1 POSITION
R1 BOTTLE SIZE
R2 VOLUME
R2 POSITION
R2 BOTTLE SIZE
R3 VOLUME
R3 POSITION
R3 BOTTLE SIZE
CALIBRATION TYPE (TYPE)
CALIBRATION TYPE (WIGHT)
CALIBRATOR CONC. 1
CALIBRATOR POSITION 1
CALIBRATOR CONC. 2
CALIBRATOR POSITION 2
CALIBRATOR CONC. 3
CALIBRATOR POSITION 3
CALIBRATOR CONC. 4
CALIBRATOR POSITION 4
CALIBRATOR CONC. 5
CALIBRATOR POSITION 5
CALIBRATOR CONC. 6
CALIBRATOR POSITION 6
S1 ABS
K FACTOR
K 2 FACTOR
K 2 FACTOR
K 4 FACTOR
K 5 FACTOR
A FACTOR
B FACTOR
C FACTOR
SD LIMIT
DUPLICATE LIMIT
SENS.MLIMIT
S1 ABS LIMIT (L)
S1 ABS LIMIT (H)
ABS LIMIT
ABS LIMIT (D/I)
PRZ LIMIT
PRZ LIMIT (U/D)
PRZ (END POINT)
EXPECT. VALUE (L)
EXPECT. VALUE (H)
INSTR. FACTOR (A)
INSTR. FACTOR (B)
KEY SETTING

DESCRIPTION
ALT
RATE A
0
10
22
29
0
0
600
340
30
240
*
*
0
0
0
60
*
*
LINEAR
0
0.00
*
@
*
0
0
0
0
0
0
0
0
0
10000
10000
10000
10000
10000
0
0
0
0.1
100
32000
-32000
32000
0
1
32000
D
35
*
*
1.0

0.0
POS. TECLADO

REVISO 00 - MAI/2006

SAC BioTcnica Ind e Com. Ltda.


Tel / Fax: +55 35 3214-4646 Varginha MG Brasil.
Site: www.biotecnica.ind.br / e-mail: sac@biotecnicaltda.com.br

Programaes de Automao Biotcnica


HITACHI 902
PRODUTO
CATLOGO
METODOLOGIA
N DETERMINAES

AST/TGO
BT 11.008.00
CINTICO UV
833

- O nmero de determinaes foi calculado


desconsiderando o volume morto do frasco de
reagente do equipamento.
- Recomenda-se a leitura das Instrues de Uso
(I.U) antes da utilizao do produto.
As informaes complementares para realizao do
teste esto descritas no Protocolo de Automao
ao lado:
PREPARAO DOS REAGENTES
R1: Reagente A - Pronto para uso
R3: Reagente B - Pronto para uso
CALIBRADORES
CONTROLES
Para avaliar o
desempenho do teste,
sugere-se a utilizao dos
controles Biotcnica:
Autocal H
CAT BT 13.002.00
- Quantinorm
CAT BT 13.003.00
- Quantialt
CAT BT 13.004.00
OBSERVAES ESPECIAIS
No Aplicvel
@ Inserir a concentrao indicada no calibrador
Biotcnica Autocal H
* Parmetro definido pelo usurio

ESTE MARCA REGISTRADA DE SEUS FABRICANTES.

NO.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58

TEST
TEST NAME
ASSAY CODE (METHOD)
ASSAY CODE (TEST)
REACTION TIME
ASSAY POINT 1
ASSAY POINT 2
ASSAY POINT 3
ASSAY POINT 4
WAVELENGHT (SUB)
WAVELENGHT (MAIN)
SAMPLE VOLUME
R1 VOLUME
R1 POSITION
R1 BOTTLE SIZE
R2 VOLUME
R2 POSITION
R2 BOTTLE SIZE
R3 VOLUME
R3 POSITION
R3 BOTTLE SIZE
CALIBRATION TYPE (TYPE)
CALIBRATION TYPE (WIGHT)
CALIBRATOR CONC. 1
CALIBRATOR POSITION 1
CALIBRATOR CONC. 2
CALIBRATOR POSITION 2
CALIBRATOR CONC. 3
CALIBRATOR POSITION 3
CALIBRATOR CONC. 4
CALIBRATOR POSITION 4
CALIBRATOR CONC. 5
CALIBRATOR POSITION 5
CALIBRATOR CONC. 6
CALIBRATOR POSITION 6
S1 ABS
K FACTOR
K 2 FACTOR
K 2 FACTOR
K 4 FACTOR
K 5 FACTOR
A FACTOR
B FACTOR
C FACTOR
SD LIMIT
DUPLICATE LIMIT
SENS.MLIMIT
S1 ABS LIMIT (L)
S1 ABS LIMIT (H)
ABS LIMIT
ABS LIMIT (D/I)
PRZ LIMIT
PRZ LIMIT (U/D)
PRZ (END POINT)
EXPECT. VALUE (L)
EXPECT. VALUE (H)
INSTR. FACTOR (A)
INSTR. FACTOR (B)
KEY SETTING

DESCRIPTION
AST
RATE A
0
10
22
29
0
0
600
340
30
240
*
*
0
0
0
60
*
*
LINEAR
0
0.00
*
@
*
0
0
0
0
0
0
0
0
0
10000
10000
10000
10000
10000
0
0
0
0.1
100
32000
-32000
32000
0
1
32000
D
35
*
*
1.0

0.0
POS. TECLADO

REVISO 00 - MAI/2006

SAC BioTcnica Ind e Com. Ltda.


Tel / Fax: +55 35 3214-4646 Varginha MG Brasil.
Site: www.biotecnica.ind.br / e-mail: sac@biotecnicaltda.com.br

Programaes de Automao Biotcnica


HITACHI 902
PRODUTO
CATLOGO
METODOLOGIA
N DETERMINAES

CLCIO ASX
BT 12.002.00
ARSENAZO III
333

- O nmero de determinaes foi calculado


desconsiderando o volume morto do frasco de
reagente do equipamento.
- Recomenda-se a leitura das Instrues de Uso
(I.U) antes da utilizao do produto.
As informaes complementares para realizao do
teste esto descritas no Protocolo de Automao
ao lado:
PREPARAO DOS REAGENTES
R1: Reagente - Pronto para uso
CALIBRADORES
CONTROLES
Para avaliar o
desempenho do teste,
sugere-se a utilizao dos
controles Biotcnica:
Autocal H
CAT BT 13.002.00
- Quantinorm
CAT BT 13.003.00
- Quantialt
CAT BT 13.004.00
OBSERVAES ESPECIAIS
No Aplicvel

@ Inserir a concentrao indicada no calibrador


Biotcnica Autocal H
* Parmetro definido pelo usurio

ESTE MARCA REGISTRADA DE SEUS FABRICANTES.

NO.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58

TEST
TEST NAME
ASSAY CODE (METHOD)
ASSAY CODE (TEST)
REACTION TIME
ASSAY POINT 1
ASSAY POINT 2
ASSAY POINT 3
ASSAY POINT 4
WAVELENGHT (SUB)
WAVELENGHT (MAIN)
SAMPLE VOLUME
R1 VOLUME
R1 POSITION
R1 BOTTLE SIZE
R2 VOLUME
R2 POSITION
R2 BOTTLE SIZE
R3 VOLUME
R3 POSITION
R3 BOTTLE SIZE
CALIBRATION TYPE (TYPE)
CALIBRATION TYPE (WIGHT)
CALIBRATOR CONC. 1
CALIBRATOR POSITION 1
CALIBRATOR CONC. 2
CALIBRATOR POSITION 2
CALIBRATOR CONC. 3
CALIBRATOR POSITION 3
CALIBRATOR CONC. 4
CALIBRATOR POSITION 4
CALIBRATOR CONC. 5
CALIBRATOR POSITION 5
CALIBRATOR CONC. 6
CALIBRATOR POSITION 6
S1 ABS
K FACTOR
K 2 FACTOR
K 2 FACTOR
K 4 FACTOR
K 5 FACTOR
A FACTOR
B FACTOR
C FACTOR
SD LIMIT
DUPLICATE LIMIT
SENS.MLIMIT
S1 ABS LIMIT (L)
S1 ABS LIMIT (H)
ABS LIMIT
ABS LIMIT (D/I)
PRZ LIMIT
PRZ LIMIT (U/D)
PRZ (END POINT)
EXPECT. VALUE (L)
EXPECT. VALUE (H)
INSTR. FACTOR (A)
INSTR. FACTOR (B)
KEY SETTING

DESCRIPTION
CAL
1 POINT
0
10
35
0
0
0
0
660
3.0
300
*
*
0
0
0
0
0
0
LINEAR
0
0.00
*
@
*
0
0
0
0
0
0
0
0
0
10000
10000
10000
10000
10000
0
0
0
0.1
100
32000
-32000
32000
0
1
32000
U
35
*
*
1.0

0.0
POS. TECLADO

REVISO 00 - MAI/2006

SAC BioTcnica Ind e Com. Ltda.


Tel / Fax: +55 35 3214-4646 Varginha MG Brasil.
Site: www.biotecnica.ind.br / e-mail: sac@biotecnicaltda.com.br

Programaes de Automao Biotcnica


HITACHI 902
PRODUTO
CATLOGO
METODOLOGIA
N DETERMINAES

CLCIO
BT 12.001.00
CRESOLFTALENA
250

- O nmero de determinaes foi calculado


desconsiderando o volume morto do frasco de
reagente do equipamento.
- Recomenda-se a leitura das Instrues de Uso
(I.U) antes da utilizao do produto.
As informaes complementares para realizao do
teste esto descritas no Protocolo de Automao
ao lado:
PREPARAO DOS REAGENTES
R1: Reagente A - Pronto para uso
R2: Reagente B - Pronto para uso
CALIBRADORES
CONTROLES
Para avaliar o
desempenho do teste,
sugere-se a utilizao dos
controles Biotcnica:
Autocal H
CAT BT 13.002.00
- Quantinorm
CAT BT 13.003.00
- Quantialt
CAT BT 13.004.00
OBSERVAES ESPECIAIS
No Aplicvel

@ Inserir a concentrao indicada no calibrador


Biotcnica Autocal H
* Parmetro definido pelo usurio

ESTE MARCA REGISTRADA DE SEUS FABRICANTES.

NO.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58

TEST
TEST NAME
ASSAY CODE (METHOD)
ASSAY CODE (TEST)
REACTION TIME
ASSAY POINT 1
ASSAY POINT 2
ASSAY POINT 3
ASSAY POINT 4
WAVELENGHT (SUB)
WAVELENGHT (MAIN)
SAMPLE VOLUME
R1 VOLUME
R1 POSITION
R1 BOTTLE SIZE
R2 VOLUME
R2 POSITION
R2 BOTTLE SIZE
R3 VOLUME
R3 POSITION
R3 BOTTLE SIZE
CALIBRATION TYPE (TYPE)
CALIBRATION TYPE (WIGHT)
CALIBRATOR CONC. 1
CALIBRATOR POSITION 1
CALIBRATOR CONC. 2
CALIBRATOR POSITION 2
CALIBRATOR CONC. 3
CALIBRATOR POSITION 3
CALIBRATOR CONC. 4
CALIBRATOR POSITION 4
CALIBRATOR CONC. 5
CALIBRATOR POSITION 5
CALIBRATOR CONC. 6
CALIBRATOR POSITION 6
S1 ABS
K FACTOR
K 2 FACTOR
K 2 FACTOR
K 4 FACTOR
K 5 FACTOR
A FACTOR
B FACTOR
C FACTOR
SD LIMIT
DUPLICATE LIMIT
SENS.MLIMIT
S1 ABS LIMIT (L)
S1 ABS LIMIT (H)
ABS LIMIT
ABS LIMIT (D/I)
PRZ LIMIT
PRZ LIMIT (U/D)
PRZ (END POINT)
EXPECT. VALUE (L)
EXPECT. VALUE (H)
INSTR. FACTOR (A)
INSTR. FACTOR (B)
KEY SETTING

DESCRIPTION
CAL
2 POINT END
0
5
5
17
0
0
660
570
4
200
*
*
200
*
*
*
0
0
LINEAR
0
0.00
*
@
*
0
0
0
0
0
0
0
0
0
10000
10000
10000
10000
10000
0
0
0
0.1
100
32000
-32000
32000
0
1
32000
U
35
*
*
1.0

0.0
POS. TECLADO

REVISO 00 - MAI/2006

SAC BioTcnica Ind e Com. Ltda.


Tel / Fax: +55 35 3214-4646 Varginha MG Brasil.
Site: www.biotecnica.ind.br / e-mail: sac@biotecnicaltda.com.br

Programaes de Automao Biotcnica


HITACHI 902
PRODUTO
CATLOGO
METODOLOGIA
N DETERMINAES

CK NAC
BT 11.002.00
CINTICO UV
100

- O nmero de determinaes foi calculado


desconsiderando o volume morto do frasco de
reagente do equipamento.
- Recomenda-se a leitura das Instrues de Uso
(I.U) antes da utilizao do produto.
As informaes complementares para realizao do
teste esto descritas no Protocolo de Automao
ao lado:
PREPARAO DOS REAGENTES
R1: Reagente A - Pronto para uso
R3: Reagente B - Pronto para uso
CALIBRADORES
CONTROLES
Para avaliar o
desempenho do teste,
sugere-se a utilizao dos
controles Biotcnica:
Autocal H
CAT BT 13.002.00
- Quantinorm
CAT BT 13.003.00
- Quantialt
CAT BT 13.004.00
OBSERVAES ESPECIAIS
No Aplicvel

@ Inserir a concentrao indicada no calibrador


Biotcnica Autocal H
* Parmetro definido pelo usurio

ESTE MARCA REGISTRADA DE SEUS FABRICANTES.

NO.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58

TEST
TEST NAME
ASSAY CODE (METHOD)
ASSAY CODE (TEST)
REACTION TIME
ASSAY POINT 1
ASSAY POINT 2
ASSAY POINT 3
ASSAY POINT 4
WAVELENGHT (SUB)
WAVELENGHT (MAIN)
SAMPLE VOLUME
R1 VOLUME
R1 POSITION
R1 BOTTLE SIZE
R2 VOLUME
R2 POSITION
R2 BOTTLE SIZE
R3 VOLUME
R3 POSITION
R3 BOTTLE SIZE
CALIBRATION TYPE (TYPE)
CALIBRATION TYPE (WIGHT)
CALIBRATOR CONC. 1
CALIBRATOR POSITION 1
CALIBRATOR CONC. 2
CALIBRATOR POSITION 2
CALIBRATOR CONC. 3
CALIBRATOR POSITION 3
CALIBRATOR CONC. 4
CALIBRATOR POSITION 4
CALIBRATOR CONC. 5
CALIBRATOR POSITION 5
CALIBRATOR CONC. 6
CALIBRATOR POSITION 6
S1 ABS
K FACTOR
K 2 FACTOR
K 2 FACTOR
K 4 FACTOR
K 5 FACTOR
A FACTOR
B FACTOR
C FACTOR
SD LIMIT
DUPLICATE LIMIT
SENS.MLIMIT
S1 ABS LIMIT (L)
S1 ABS LIMIT (H)
ABS LIMIT
ABS LIMIT (D/I)
PRZ LIMIT
PRZ LIMIT (U/L)
PRZ (END POINT)
EXPECT. VALUE (L)
EXPECT. VALUE (H)
INSTR. FACTOR (A)
INSTR. FACTOR (B)
KEY SETTING

DESCRIPTION
CK NAC
RATE A
0
10
25
32
0
0
600
340
10
200
*
*
0
0
0
50
*
*
LINEAR
0
0.00
*
@
*
0
0
0
0
0
0
0
0
0
10000
10000
10000
10000
10000
0
0
0
0.1
35
340
-32000
32000
0
1
32000
L
35
*
*
1.0

0.0
POS. TECLADO

REVISO 00 - MAI/2006

SAC BioTcnica Ind e Com. Ltda.


Tel / Fax: +55 35 3214-4646 Varginha MG Brasil.
Site: www.biotecnica.ind.br / e-mail: sac@biotecnicaltda.com.br

Programaes de Automao Biotcnica


HITACHI 902
PRODUTO
CATLOGO
METODOLOGIA
N DETERMINAES

CK MB
BT 11.003.00
CINTICO UV
100

- O nmero de determinaes foi calculado


desconsiderando o volume morto do frasco de
reagente do equipamento.
- Recomenda-se a leitura das Instrues de Uso
(I.U) antes da utilizao do produto.
As informaes complementares para realizao do
teste esto descritas no Protocolo de Automao
ao lado:
PREPARAO DOS REAGENTES
R1: Reagente A - Pronto para uso
R3: Reagente B - Pronto para uso
CALIBRADORES
CONTROLES
Para avaliar o
desempenho do teste,
sugere-se a utilizao dos
controles Biotcnica:
Autocal H
CAT BT 13.002.00
- Quantinorm
CAT BT 13.003.00
- Quantialt
CAT BT 13.004.00
OBSERVAES ESPECIAIS
No Aplicvel

@ Inserir a concentrao indicada no calibrador


Biotcnica Autocal H
* Parmetro definido pelo usurio

ESTE MARCA REGISTRADA DE SEUS FABRICANTES.

NO.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58

TEST
TEST NAME
ASSAY CODE (METHOD)
ASSAY CODE (TEST)
REACTION TIME
ASSAY POINT 1
ASSAY POINT 2
ASSAY POINT 3
ASSAY POINT 4
WAVELENGHT (SUB)
WAVELENGHT (MAIN)
SAMPLE VOLUME
R1 VOLUME
R1 POSITION
R1 BOTTLE SIZE
R2 VOLUME
R2 POSITION
R2 BOTTLE SIZE
R3 VOLUME
R3 POSITION
R3 BOTTLE SIZE
CALIBRATION TYPE (TYPE)
CALIBRATION TYPE (WIGHT)
CALIBRATOR CONC. 1
CALIBRATOR POSITION 1
CALIBRATOR CONC. 2
CALIBRATOR POSITION 2
CALIBRATOR CONC. 3
CALIBRATOR POSITION 3
CALIBRATOR CONC. 4
CALIBRATOR POSITION 4
CALIBRATOR CONC. 5
CALIBRATOR POSITION 5
CALIBRATOR CONC. 6
CALIBRATOR POSITION 6
S1 ABS
K FACTOR
K 2 FACTOR
K 2 FACTOR
K 4 FACTOR
K 5 FACTOR
A FACTOR
B FACTOR
C FACTOR
SD LIMIT
DUPLICATE LIMIT
SENS.MLIMIT
S1 ABS LIMIT (L)
S1 ABS LIMIT (H)
ABS LIMIT
ABS LIMIT (D/I)
PRZ LIMIT
PRZ LIMIT (U/L)
PRZ (END POINT)
EXPECT. VALUE (L)
EXPECT. VALUE (H)
INSTR. FACTOR (A)
INSTR. FACTOR (B)
KEY SETTING

DESCRIPTION
CK MB
RATE A
0
10
25
35
0
0
600
340
10
200
*
*
0
0
0
50
*
*
LINEAR
0
0.00
*
@
*
0
0
0
0
0
0
0
0
0
10000
10000
10000
10000
10000
0
0
0
0.1
115
32000
-32000
32000
0
1
32000
L
35
*
*
1.0

0.0
POS. TECLADO

REVISO 00 - MAI/2006

SAC BioTcnica Ind e Com. Ltda.


Tel / Fax: +55 35 3214-4646 Varginha MG Brasil.
Site: www.biotecnica.ind.br / e-mail: sac@biotecnicaltda.com.br

Programaes de Automao Biotcnica


HITACHI 902
PRODUTO
CATLOGO
METODOLOGIA
N DETERMINAES

COLESTEROL
BT 10.004.00
ENZIMTICO
COLORIMTRICO
3333

- O nmero de determinaes foi calculado


desconsiderando o volume morto do frasco de
reagente do equipamento.
- Recomenda-se a leitura das Instrues de Uso
(I.U) antes da utilizao do produto.
As informaes complementares para realizao do
teste esto descritas no Protocolo de Automao
ao lado:
PREPARAO DOS REAGENTES
R1: Reagente - Pronto para uso
CALIBRADORES
CONTROLES
Para avaliar o
desempenho do teste,
sugere-se a utilizao dos
controles Biotcnica:
Autocal H
CAT BT 13.002.00
- Quantinorm
CAT BT 13.003.00
- Quantialt
CAT BT 13.004.00
OBSERVAES ESPECIAIS
No Aplicvel

@ Inserir a concentrao indicada no calibrador


Biotcnica Autocal H
* Parmetro definido pelo usurio

ESTE MARCA REGISTRADA DE SEUS FABRICANTES.

NO.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58

TEST
TEST NAME
ASSAY CODE (METHOD)
ASSAY CODE (TEST)
REACTION TIME
ASSAY POINT 1
ASSAY POINT 2
ASSAY POINT 3
ASSAY POINT 4
WAVELENGHT (SUB)
WAVELENGHT (MAIN)
SAMPLE VOLUME
R1 VOLUME
R1 POSITION
R1 BOTTLE SIZE
R2 VOLUME
R2 POSITION
R2 BOTTLE SIZE
R3 VOLUME
R3 POSITION
R3 BOTTLE SIZE
CALIBRATION TYPE (TYPE)
CALIBRATION TYPE (WIGHT)
CALIBRATOR CONC. 1
CALIBRATOR POSITION 1
CALIBRATOR CONC. 2
CALIBRATOR POSITION 2
CALIBRATOR CONC. 3
CALIBRATOR POSITION 3
CALIBRATOR CONC. 4
CALIBRATOR POSITION 4
CALIBRATOR CONC. 5
CALIBRATOR POSITION 5
CALIBRATOR CONC. 6
CALIBRATOR POSITION 6
S1 ABS
K FACTOR
K 2 FACTOR
K 2 FACTOR
K 4 FACTOR
K 5 FACTOR
A FACTOR
B FACTOR
C FACTOR
SD LIMIT
DUPLICATE LIMIT
SENS.MLIMIT
S1 ABS LIMIT (L)
S1 ABS LIMIT (H)
ABS LIMIT
ABS LIMIT (D/I)
PRZ LIMIT
PRZ LIMIT (U/D)
PRZ (END POINT)
EXPECT. VALUE (L)
EXPECT. VALUE (H)
INSTR. FACTOR (A)
INSTR. FACTOR (B)
KEY SETTING

DESCRIPTION
COL
1 POINT
0
10
35
0
0
0
660
505
3.0
300
*
*
0
0
0
0
0
0
LINEAR
0
0.00
*
@
*
0
0
0
0
0
0
0
0
0
10000
10000
10000
10000
10000
0
0
0
0.1
220
32000
-32000
32000
0
1
32000
U
35
*
*
1.0

0.0
POS. TECLADO

REVISO 00 - MAI/2006

SAC BioTcnica Ind e Com. Ltda.


Tel / Fax: +55 35 3214-4646 Varginha MG Brasil.
Site: www.biotecnica.ind.br / e-mail: sac@biotecnicaltda.com.br

Programaes de Automao Biotcnica


HITACHI 902
PRODUTO
CATLOGO
METODOLOGIA
N DETERMINAES

CREATININA
BT 10.007.00
CINTICO
COLORIMTRICO
1250

- O nmero de determinaes foi calculado


desconsiderando o volume morto do frasco de
reagente do equipamento.
- Recomenda-se a leitura das Instrues de Uso
(I.U) antes da utilizao do produto.
As informaes complementares para realizao do
teste esto descritas no Protocolo de Automao
ao lado:
PREPARAO DOS REAGENTES
R1: Reagente B (NaOH) - Pronto para uso
R3: Reagente A (cido Pcrico) - Pronto para uso
CALIBRADORES
CONTROLES
Para avaliar o
desempenho do teste,
sugere-se a utilizao dos
controles Biotcnica:
Autocal H
CAT BT 13.002.00
- Quantinorm
CAT BT 13.003.00
- Quantialt
CAT BT 13.004.00
OBSERVAES ESPECIAIS
No Aplicvel

@ Inserir a concentrao indicada no calibrador


Biotcnica Autocal H
* Parmetro definido pelo usurio

ESTE MARCA REGISTRADA DE SEUS FABRICANTES.

NO.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58

TEST
TEST NAME
ASSAY CODE (METHOD)
ASSAY CODE (TEST)
REACTION TIME
ASSAY POINT 1
ASSAY POINT 2
ASSAY POINT 3
ASSAY POINT 4
WAVELENGHT (SUB)
WAVELENGHT (MAIN)
SAMPLE VOLUME
R1 VOLUME
R1 POSITION
R1 BOTTLE SIZE
R2 VOLUME
R2 POSITION
R2 BOTTLE SIZE
R3 VOLUME
R3 POSITION
R3 BOTTLE SIZE
CALIBRATION TYPE (TYPE)
CALIBRATION TYPE (WIGHT)
CALIBRATOR CONC. 1
CALIBRATOR POSITION 1
CALIBRATOR CONC. 2
CALIBRATOR POSITION 2
CALIBRATOR CONC. 3
CALIBRATOR POSITION 3
CALIBRATOR CONC. 4
CALIBRATOR POSITION 4
CALIBRATOR CONC. 5
CALIBRATOR POSITION 5
CALIBRATOR CONC. 6
CALIBRATOR POSITION 6
S1 ABS
K FACTOR
K 2 FACTOR
K 2 FACTOR
K 4 FACTOR
K 5 FACTOR
A FACTOR
B FACTOR
C FACTOR
SD LIMIT
DUPLICATE LIMIT
SENS.MLIMIT
S1 ABS LIMIT (L)
S1 ABS LIMIT (H)
ABS LIMIT
ABS LIMIT (D/I)
PRZ LIMIT
PRZ LIMIT (U/D)
PRZ (END POINT)
EXPECT. VALUE (L)
EXPECT. VALUE (H)
INSTR. FACTOR (A)
INSTR. FACTOR (B)
KEY SETTING

DESCRIPTION
CRE
2 POINT RATE
0
10
22
32
0
0
570
505
40
200
*
*
0
0
0
200
*
*
LINEAR
0
0.00
*
@
*
0
0
0
0
0
0
0
0
0
10000
10000
10000
10000
10000
0
0
0
0.1
100
32000
-32000
32000
0
1
32000
U
35
*
*
1.0
0.0
POS. TECLADO

REVISO 00 - MAI/2006

SAC BioTcnica Ind e Com. Ltda.


Tel / Fax: +55 35 3214-4646 Varginha MG Brasil.
Site: www.biotecnica.ind.br / e-mail: sac@biotecnicaltda.com.br

Programaes de Automao Biotcnica


HITACHI 902
PRODUTO
CATLOGO
METODOLOGIA
N DETERMINAES

DESIDROGENASE
LCTICA
BT 11.004.00
CINTICO UV
166

- O nmero de determinaes foi calculado


desconsiderando o volume morto do frasco de
reagente do equipamento.
- Recomenda-se a leitura das Instrues de Uso
(I.U) antes da utilizao do produto.
As informaes complementares para realizao do
teste esto descritas no Protocolo de Automao
ao lado:
PREPARAO DOS REAGENTES
R1: Reagente A - Pronto para uso
R3: Reagente B - Pronto para uso
CALIBRADORES
CONTROLES
Para avaliar o
desempenho do teste,
sugere-se a utilizao dos
controles Biotcnica:
Autocal H
CAT BT 13.002.00
- Quantinorm
CAT BT 13.003.00
- Quantialt
CAT BT 13.004.00
OBSERVAES ESPECIAIS
No Aplicvel

@ Inserir a concentrao indicada no calibrador


Biotcnica Autocal H
* Parmetro definido pelo usurio

ESTE MARCA REGISTRADA DE SEUS FABRICANTES.

NO.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58

TEST
TEST NAME
ASSAY CODE (METHOD)
ASSAY CODE (TEST)
REACTION TIME
ASSAY POINT 1
ASSAY POINT 2
ASSAY POINT 3
ASSAY POINT 4
WAVELENGHT (SUB)
WAVELENGHT (MAIN)
SAMPLE VOLUME
R1 VOLUME
R1 POSITION
R1 BOTTLE SIZE
R2 VOLUME
R2 POSITION
R2 BOTTLE SIZE
R3 VOLUME
R3 POSITION
R3 BOTTLE SIZE
CALIBRATION TYPE (TYPE)
CALIBRATION TYPE (WIGHT)
CALIBRATOR CONC. 1
CALIBRATOR POSITION 1
CALIBRATOR CONC. 2
CALIBRATOR POSITION 2
CALIBRATOR CONC. 3
CALIBRATOR POSITION 3
CALIBRATOR CONC. 4
CALIBRATOR POSITION 4
CALIBRATOR CONC. 5
CALIBRATOR POSITION 5
CALIBRATOR CONC. 6
CALIBRATOR POSITION 6
S1 ABS
K FACTOR
K 2 FACTOR
K 2 FACTOR
K 4 FACTOR
K 5 FACTOR
A FACTOR
B FACTOR
C FACTOR
SD LIMIT
DUPLICATE LIMIT
SENS.MLIMIT
S1 ABS LIMIT (L)
S1 ABS LIMIT (H)
ABS LIMIT
ABS LIMIT (D/I)
PRZ LIMIT
PRZ LIMIT (U/D)
PRZ (END POINT)
EXPECT. VALUE (L)
EXPECT. VALUE (H)
INSTR. FACTOR (A)
INSTR. FACTOR (B)
KEY SETTING

DESCRIPTION
LDH
RATE A
0
10
22
29
0
0
600
340
6
240
*
*
0
0
0
60
*
*
LINEAR
0
0.00
*
@
*
0
0
0
0
0
0
0
0
0
10000
10000
10000
10000
10000
0
0
0
0.1
100
32000
-32000
32000
D
1
32000
D
35
*
*
1.0

0.0
POS. TECLADO

REVISO 00 - MAI/2006

SAC BioTcnica Ind e Com. Ltda.


Tel / Fax: +55 35 3214-4646 Varginha MG Brasil.
Site: www.biotecnica.ind.br / e-mail: sac@biotecnicaltda.com.br

Programaes de Automao Biotcnica


HITACHI 902
PRODUTO
CATLOGO
METODOLOGIA
N DETERMINAES

FERRO CRX
BT 12.004.00
ENZIMTICO
COLORIMTRICO
333

- O nmero de determinaes foi calculado


desconsiderando o volume morto do frasco de
reagente do equipamento.
- Recomenda-se a leitura das Instrues de Uso
(I.U) antes da utilizao do produto.
As informaes complementares para realizao do
teste esto descritas no Protocolo de Automao
ao lado:
PREPARAO DOS REAGENTES
Reagente pronto para uso.
CALIBRADORES
CONTROLES
Para avaliar o
desempenho do teste,
sugere-se a utilizao dos
controles Biotcnica:
Autocal H
CAT BT 13.002.00
- Quantinorm
CAT BT 13.003.00
- Quantialt
CAT BT 13.004.00
OBSERVAES ESPECIAIS
No Aplicvel

@ Inserir a concentrao indicada no calibrador


Biotcnica Autocal H
* Parmetro definido pelo usurio

ESTE MARCA REGISTRADA DE SEUS FABRICANTES.

NO.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58

TEST
TEST NAME
ASSAY CODE (METHOD)
ASSAY CODE (TEST)
REACTION TIME
ASSAY POINT 1
ASSAY POINT 2
ASSAY POINT 3
ASSAY POINT 4
WAVELENGHT (SUB)
WAVELENGHT (MAIN)
SAMPLE VOLUME
R1 VOLUME
R1 POSITION
R1 BOTTLE SIZE
R2 VOLUME
R2 POSITION
R2 BOTTLE SIZE
R3 VOLUME
R3 POSITION
R3 BOTTLE SIZE
CALIBRATION TYPE (TYPE)
CALIBRATION TYPE (WIGHT)
CALIBRATOR CONC. 1
CALIBRATOR POSITION 1
CALIBRATOR CONC. 2
CALIBRATOR POSITION 2
CALIBRATOR CONC. 3
CALIBRATOR POSITION 3
CALIBRATOR CONC. 4
CALIBRATOR POSITION 4
CALIBRATOR CONC. 5
CALIBRATOR POSITION 5
CALIBRATOR CONC. 6
CALIBRATOR POSITION 6
S1 ABS
K FACTOR
K 2 FACTOR
K 2 FACTOR
K 4 FACTOR
K 5 FACTOR
A FACTOR
B FACTOR
C FACTOR
SD LIMIT
DUPLICATE LIMIT
SENS.MLIMIT
S1 ABS LIMIT (L)
S1 ABS LIMIT (H)
ABS LIMIT
ABS LIMIT (D/I)
PRZ LIMIT
PRZ LIMIT (U/D)
PRZ (END POINT)
EXPECT. VALUE (L)
EXPECT. VALUE (H)
INSTR. FACTOR (A)
INSTR. FACTOR (B)
KEY SETTING

DESCRIPTION
FER
1 POINT
0
5
18
0
0
0
0
600
12
300
*
*
0
0
0
0
0
0
LINEAR
0
0.00
*
@
*
0
0
0
0
0
0
0
0
0
10000
10000
10000
10000
10000
0
0
0
0.1
100
32000
-32000
32000
0
1
32000
U
35
*
*
1.0

0.0
POS. TECLADO

REVISO 00 - MAI/2006

SAC BioTcnica Ind e Com. Ltda.


Tel / Fax: +55 35 3214-4646 Varginha MG Brasil.
Site: www.biotecnica.ind.br / e-mail: sac@biotecnicaltda.com.br

Programaes de Automao Biotcnica


HITACHI 902
PRODUTO
CATLOGO
METODOLOGIA
N DETERMINAES

FERRO FEZ
BT 12.005.00
FEROZINE
160

- O nmero de determinaes foi calculado


desconsiderando o volume morto do frasco de
reagente do equipamento.
- Recomenda-se a leitura das Instrues de Uso
(I.U) antes da utilizao do produto.
As informaes complementares para realizao do
teste esto descritas no Protocolo de Automao
ao lado:
PREPARAO DOS REAGENTES
R1: Reagente A - Tampo
R3: Reagente B - Ferrozine
CALIBRADORES
CONTROLES
Para avaliar o
desempenho do teste,
sugere-se a utilizao dos
controles Biotcnica:
Autocal H
CAT BT 13.002.00
- Quantinorm
CAT BT 13.003.00
- Quantialt
CAT BT 13.004.00
OBSERVAES ESPECIAIS
No Aplicvel

@ Inserir a concentrao indicada no calibrador


Biotcnica Autocal H
* Parmetro definido pelo usurio

ESTE MARCA REGISTRADA DE SEUS FABRICANTES.

NO.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58

TEST
TEST NAME
ASSAY CODE (METHOD)
ASSAY CODE (TEST)
REACTION TIME
ASSAY POINT 1
ASSAY POINT 2
ASSAY POINT 3
ASSAY POINT 4
WAVELENGHT (SUB)
WAVELENGHT (MAIN)
SAMPLE VOLUME
R1 VOLUME
R1 POSITION
R1 BOTTLE SIZE
R2 VOLUME
R2 POSITION
R2 BOTTLE SIZE
R3 VOLUME
R3 POSITION
R3 BOTTLE SIZE
CALIBRATION TYPE (TYPE)
CALIBRATION TYPE (WIGHT)
CALIBRATOR CONC. 1
CALIBRATOR POSITION 1
CALIBRATOR CONC. 2
CALIBRATOR POSITION 2
CALIBRATOR CONC. 3
CALIBRATOR POSITION 3
CALIBRATOR CONC. 4
CALIBRATOR POSITION 4
CALIBRATOR CONC. 5
CALIBRATOR POSITION 5
CALIBRATOR CONC. 6
CALIBRATOR POSITION 6
S1 ABS
K FACTOR
K 2 FACTOR
K 2 FACTOR
K 4 FACTOR
K 5 FACTOR
A FACTOR
B FACTOR
C FACTOR
SD LIMIT
DUPLICATE LIMIT
SENS.MLIMIT
S1 ABS LIMIT (L)
S1 ABS LIMIT (H)
ABS LIMIT
ABS LIMIT (D/I)
PRZ LIMIT
PRZ LIMIT (U/D)
PRZ (END POINT)
EXPECT. VALUE (L)
EXPECT. VALUE (H)
INSTR. FACTOR (A)
INSTR. FACTOR (B)
KEY SETTING

DESCRIPTION
FE FEZ
2 POINT END
0
10
18
35
0
0
660
570
65
200
*
*
0
0
0
50
*
*
LINEAR
0
0.00
*
@
*
0
0
0
0
0
0
0
0
0
10000
10000
10000
10000
10000
0
0
0
0.1
100
32000
-32000
32000
0
1
32000
U
35
*
*
1.0

0.0
POS. TECLADO

REVISO 00 - MAI/2006

SAC BioTcnica Ind e Com. Ltda.


Tel / Fax: +55 35 3214-4646 Varginha MG Brasil.
Site: www.biotecnica.ind.br / e-mail: sac@biotecnicaltda.com.br

Programaes de Automao Biotcnica


HITACHI 902
PRODUTO
CATLOGO
METODOLOGIA
N DETERMINAES

FOSFATASE
ALCALINA
BT 11.005.00
CINTICO
COLORIMTRICO
166

- O nmero de determinaes foi calculado


desconsiderando o volume morto do frasco de
reagente do equipamento.
- Recomenda-se a leitura das Instrues de Uso
(I.U) antes da utilizao do produto.
As informaes complementares para realizao do
teste esto descritas no Protocolo de Automao
ao lado:
PREPARAO DOS REAGENTES
R1: Reagente A - Pronto para uso
R3: Reagente B - Pronto para uso
CALIBRADORES
CONTROLES
Para avaliar o
desempenho do teste,
sugere-se a utilizao dos
controles Biotcnica:
Autocal H
CAT BT 13.002.00
- Quantinorm
CAT BT 13.003.00
- Quantialt
CAT BT 13.004.00
OBSERVAES ESPECIAIS
No Aplicvel

@ Inserir a concentrao indicada no calibrador


Biotcnica Autocal H
* Parmetro definido pelo usurio

ESTE MARCA REGISTRADA DE SEUS FABRICANTES.

NO.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58

TEST
TEST NAME
ASSAY CODE (METHOD)
ASSAY CODE (TEST)
REACTION TIME
ASSAY POINT 1
ASSAY POINT 2
ASSAY POINT 3
ASSAY POINT 4
WAVELENGHT (SUB)
WAVELENGHT (MAIN)
SAMPLE VOLUME
R1 VOLUME
R1 POSITION
R1 BOTTLE SIZE
R2 VOLUME
R2 POSITION
R2 BOTTLE SIZE
R3 VOLUME
R3 POSITION
R3 BOTTLE SIZE
CALIBRATION TYPE (TYPE)
CALIBRATION TYPE (WIGHT)
CALIBRATOR CONC. 1
CALIBRATOR POSITION 1
CALIBRATOR CONC. 2
CALIBRATOR POSITION 2
CALIBRATOR CONC. 3
CALIBRATOR POSITION 3
CALIBRATOR CONC. 4
CALIBRATOR POSITION 4
CALIBRATOR CONC. 5
CALIBRATOR POSITION 5
CALIBRATOR CONC. 6
CALIBRATOR POSITION 6
S1 ABS
K FACTOR
K 2 FACTOR
K 2 FACTOR
K 4 FACTOR
K 5 FACTOR
A FACTOR
B FACTOR
C FACTOR
SD LIMIT
DUPLICATE LIMIT
SENS.MLIMIT
S1 ABS LIMIT (L)
S1 ABS LIMIT (H)
ABS LIMIT
ABS LIMIT (D/I)
PRZ LIMIT
PRZ LIMIT (U/D)
PRZ (END POINT)
EXPECT. VALUE (L)
EXPECT. VALUE (H)
INSTR. FACTOR (A)
INSTR. FACTOR (B)
KEY SETTING

DESCRIPTION
FAL
RATE A
0
10
22
29
0
0
600
415
6.0
240
*
*
0
0
0
60
*
*
LINEAR
0
0.00
*
@
*
0
0
0
0
0
0
0
0
0
10000
10000
10000
10000
10000
0
0
0
0.1
100
32000
-32000
32000
0
1
32000
U
35
*
*
1.0

0.0
POS. TECLADO

REVISO 00 - MAI/2006

SAC BioTcnica Ind e Com. Ltda.


Tel / Fax: +55 35 3214-4646 Varginha MG Brasil.
Site: www.biotecnica.ind.br / e-mail: sac@biotecnicaltda.com.br

Programaes de Automao Biotcnica


HITACHI 902
PRODUTO
CATLOGO
METODOLOGIA
N DETERMINAES

FSFORO UV
BT 12.006.00
MOLIBIDATO UV
166

- O nmero de determinaes foi calculado


desconsiderando o volume morto do frasco de
reagente do equipamento.
- Recomenda-se a leitura das Instrues de Uso
(I.U) antes da utilizao do produto.
As informaes complementares para realizao do
teste esto descritas no Protocolo de Automao
ao lado:
PREPARAO DOS REAGENTES
Reagente pronto para uso.
CALIBRADORES
CONTROLES
Para avaliar o
desempenho do teste,
sugere-se a utilizao dos
controles Biotcnica:
Autocal H
CAT BT 13.002.00
- Quantinorm
CAT BT 13.003.00
- Quantialt
CAT BT 13.004.00
OBSERVAES ESPECIAIS
No Aplicvel

@ Inserir a concentrao indicada no calibrador


Biotcnica Autocal H
* Parmetro definido pelo usurio

ESTE MARCA REGISTRADA DE SEUS FABRICANTES.

NO.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58

TEST
TEST NAME
ASSAY CODE (METHOD)
ASSAY CODE (TEST)
REACTION TIME
ASSAY POINT 1
ASSAY POINT 2
ASSAY POINT 3
ASSAY POINT 4
WAVELENGHT (SUB)
WAVELENGHT (MAIN)
SAMPLE VOLUME
R1 VOLUME
R1 POSITION
R1 BOTTLE SIZE
R2 VOLUME
R2 POSITION
R2 BOTTLE SIZE
R3 VOLUME
R3 POSITION
R3 BOTTLE SIZE
CALIBRATION TYPE (TYPE)
CALIBRATION TYPE (WIGHT)
CALIBRATOR CONC. 1
CALIBRATOR POSITION 1
CALIBRATOR CONC. 2
CALIBRATOR POSITION 2
CALIBRATOR CONC. 3
CALIBRATOR POSITION 3
CALIBRATOR CONC. 4
CALIBRATOR POSITION 4
CALIBRATOR CONC. 5
CALIBRATOR POSITION 5
CALIBRATOR CONC. 6
CALIBRATOR POSITION 6
S1 ABS
K FACTOR
K 2 FACTOR
K 2 FACTOR
K 4 FACTOR
K 5 FACTOR
A FACTOR
B FACTOR
C FACTOR
SD LIMIT
DUPLICATE LIMIT
SENS.MLIMIT
S1 ABS LIMIT (L)
S1 ABS LIMIT (H)
ABS LIMIT
ABS LIMIT (D/I)
PRZ LIMIT
PRZ LIMIT (U/D)
PRZ (END POINT)
EXPECT. VALUE (L)
EXPECT. VALUE (H)
INSTR. FACTOR (A)
INSTR. FACTOR (B)
KEY SETTING

DESCRIPTION
FUV
1 POINT
0
5
18
0
0
0
600
340
3.0
300
*
*
0
0
0
0
0
0
LINEAR
0
0.00
*
@
*
0
0
0
0
0
0
0
0
0
10000
10000
10000
10000
10000
0
0
0
0.1
100
32000
-32000
32000
0
1
32000
U
35
*
*
1.0

0.0
POS. TECLADO

REVISO 00 - MAI/2006

SAC BioTcnica Ind e Com. Ltda.


Tel / Fax: +55 35 3214-4646 Varginha MG Brasil.
Site: www.biotecnica.ind.br / e-mail: sac@biotecnicaltda.com.br

Programaes de Automao Biotcnica


HITACHI 902
PRODUTO
CATLOGO
METODOLOGIA
N DETERMINAES

GAMA GT
BT 11.006.00
CINTICO
COLORIMTRICO
166

- O nmero de determinaes foi calculado


desconsiderando o volume morto do frasco de
reagente do equipamento.
- Recomenda-se a leitura das Instrues de Uso
(I.U) antes da utilizao do produto.
As informaes complementares para realizao do
teste esto descritas no Protocolo de Automao
ao lado:
PREPARAO DOS REAGENTES
R1: Reagente A - Pronto para uso
R3: Reagente B - Pronto para uso
CALIBRADORES
CONTROLES
Para avaliar o
desempenho do teste,
sugere-se a utilizao dos
controles Biotcnica:
Autocal H
CAT BT 13.002.00
- Quantinorm
CAT BT 13.003.00
- Quantialt
CAT BT 13.004.00
OBSERVAES ESPECIAIS
No Aplicvel

@ Inserir a concentrao indicada no calibrador


Biotcnica Autocal H
* Parmetro definido pelo usurio

ESTE MARCA REGISTRADA DE SEUS FABRICANTES.

NO.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58

TEST
TEST NAME
ASSAY CODE (METHOD)
ASSAY CODE (TEST)
REACTION TIME
ASSAY POINT 1
ASSAY POINT 2
ASSAY POINT 3
ASSAY POINT 4
WAVELENGHT (SUB)
WAVELENGHT (MAIN)
SAMPLE VOLUME
R1 VOLUME
R1 POSITION
R1 BOTTLE SIZE
R2 VOLUME
R2 POSITION
R2 BOTTLE SIZE
R3 VOLUME
R3 POSITION
R3 BOTTLE SIZE
CALIBRATION TYPE (TYPE)
CALIBRATION TYPE (WIGHT)
CALIBRATOR CONC. 1
CALIBRATOR POSITION 1
CALIBRATOR CONC. 2
CALIBRATOR POSITION 2
CALIBRATOR CONC. 3
CALIBRATOR POSITION 3
CALIBRATOR CONC. 4
CALIBRATOR POSITION 4
CALIBRATOR CONC. 5
CALIBRATOR POSITION 5
CALIBRATOR CONC. 6
CALIBRATOR POSITION 6
S1 ABS
K FACTOR
K 2 FACTOR
K 2 FACTOR
K 4 FACTOR
K 5 FACTOR
A FACTOR
B FACTOR
C FACTOR
SD LIMIT
DUPLICATE LIMIT
SENS.MLIMIT
S1 ABS LIMIT (L)
S1 ABS LIMIT (H)
ABS LIMIT
ABS LIMIT (D/I)
PRZ LIMIT
PRZ LIMIT (U/D)
PRZ (END POINT)
EXPECT. VALUE (L)
EXPECT. VALUE (H)
INSTR. FACTOR (A)
INSTR. FACTOR (B)
KEY SETTING

DESCRIPTION
GGT
RATE A
0
10
22
29
0
0
600
415
30
240
*
*
0
0
0
60
*
*
LINEAR
0
0.00
*
@
*
0
0
0
0
0
0
0
0
0
10000
10000
10000
10000
10000
0
0
0
0.1
100
32000
-32000
32000
0
1
32000
U
35
*
*
1.0

0.0
POS. TECLADO

REVISO 00 - MAI/2006

SAC BioTcnica Ind e Com. Ltda.


Tel / Fax: +55 35 3214-4646 Varginha MG Brasil.
Site: www.biotecnica.ind.br / e-mail: sac@biotecnicaltda.com.br

Programaes de Automao Biotcnica


HITACHI 902
PRODUTO
CATLOGO
METODOLOGIA
N DETERMINAES

GLICOSE
BT 10.008.00
ENZIMTICO
COLORIMTRICO
3333

- O nmero de determinaes foi calculado


desconsiderando o volume morto do frasco de
reagente do equipamento.
- Recomenda-se a leitura das Instrues de Uso
(I.U) antes da utilizao do produto.
As informaes complementares para realizao do
teste esto descritas no Protocolo de Automao
ao lado:
PREPARAO DOS REAGENTES
R1: Reagente - Pronto para uso
CALIBRADORES
CONTROLES
Para avaliar o
desempenho do teste,
sugere-se a utilizao dos
controles Biotcnica:
Autocal H
CAT BT 13.002.00
- Quantinorm
CAT BT 13.003.00
- Quantialt
CAT BT 13.004.00
OBSERVAES ESPECIAIS
No Aplicvel

@ Inserir a concentrao indicada no calibrador


Biotcnica Autocal H
* Parmetro definido pelo usurio

ESTE MARCA REGISTRADA DE SEUS FABRICANTES.

NO.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58

TEST
TEST NAME
ASSAY CODE (METHOD)
ASSAY CODE (TEST)
REACTION TIME
ASSAY POINT 1
ASSAY POINT 2
ASSAY POINT 3
ASSAY POINT 4
WAVELENGHT (SUB)
WAVELENGHT (MAIN)
SAMPLE VOLUME
R1 VOLUME
R1 POSITION
R1 BOTTLE SIZE
R2 VOLUME
R2 POSITION
R2 BOTTLE SIZE
R3 VOLUME
R3 POSITION
R3 BOTTLE SIZE
CALIBRATION TYPE (TYPE)
CALIBRATION TYPE (WIGHT)
CALIBRATOR CONC. 1
CALIBRATOR POSITION 1
CALIBRATOR CONC. 2
CALIBRATOR POSITION 2
CALIBRATOR CONC. 3
CALIBRATOR POSITION 3
CALIBRATOR CONC. 4
CALIBRATOR POSITION 4
CALIBRATOR CONC. 5
CALIBRATOR POSITION 5
CALIBRATOR CONC. 6
CALIBRATOR POSITION 6
S1 ABS
K FACTOR
K 2 FACTOR
K 2 FACTOR
K 4 FACTOR
K 5 FACTOR
A FACTOR
B FACTOR
C FACTOR
SD LIMIT
DUPLICATE LIMIT
SENS.MLIMIT
S1 ABS LIMIT (L)
S1 ABS LIMIT (H)
ABS LIMIT
ABS LIMIT (D/I)
PRZ LIMIT
PRZ LIMIT (U/D)
PRZ (END POINT)
EXPECT. VALUE (L)
EXPECT. VALUE (H)
INSTR. FACTOR (A)
INSTR. FACTOR (B)
KEY SETTING

DESCRIPTION
GLI
1 POINT
0
5
18
0
0
0
660
505
3.0
300
*
*
0
0
0
0
0
0
LINEAR
0
0.00
*
@
*
0
0
0
0
0
0
0
0
0
10000
10000
10000
10000
10000
0
0
0
0.1
100
32000
-32000
32000
0
1
32000
U
35
*
*
1.0

0.0
POS. TECLADO

REVISO 00 - MAI/2006

SAC BioTcnica Ind e Com. Ltda.


Tel / Fax: +55 35 3214-4646 Varginha MG Brasil.
Site: www.biotecnica.ind.br / e-mail: sac@biotecnicaltda.com.br

Programaes de Automao Biotcnica


HITACHI 902
PRODUTO
CATLOGO
METODOLOGIA
N DETERMINAES

HDL COLESTEROL
BT 10.005.00
ENZIMTICO
COLORIMTRICO
400 Precipitaes

- O nmero de determinaes foi calculado


desconsiderando o volume morto do frasco de
reagente do equipamento.
- Recomenda-se a leitura das Instrues de Uso
(I.U) antes da utilizao do produto.
As informaes complementares para realizao do
teste esto descritas no Protocolo de Automao
ao lado:
PREPARAO DOS REAGENTES
Reagente pronto para uso.
CALIBRADORES
CONTROLES
Para avaliar o
desempenho do teste,
Padro de Colesterol
sugere-se a utilizao dos
HDL (incluso no kit).
controles Biotcnica:
Para proceder o
clculo do fator de
calibrao considerar
a concentrao do
padro
(@) = 40 mg/dL

- Quantinorm
CAT BT 13.003.00
- Quantialt
CAT BT 13.004.00

OBSERVAES ESPECIAIS
- Antes de realizar a colorimetria, preparar a
amostra conforme orientaes nas Instrues de
Uso do Kit.
- Para realizar a colorimetria necessrio utilizar o
reagente de Colesterol CAT BT 10.004.00

Parmetro definido pelo usurio

ESTE MARCA REGISTRADA DE SEUS FABRICANTES.

NO.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58

TEST
TEST NAME
ASSAY CODE (METHOD)
ASSAY CODE (TEST)
REACTION TIME
ASSAY POINT 1
ASSAY POINT 2
ASSAY POINT 3
ASSAY POINT 4
WAVELENGHT (SUB)
WAVELENGHT (MAIN)
SAMPLE VOLUME
R1 VOLUME
R1 POSITION
R1 BOTTLE SIZE
R2 VOLUME
R2 POSITION
R2 BOTTLE SIZE
R3 VOLUME
R3 POSITION
R3 BOTTLE SIZE
CALIBRATION TYPE (TYPE)
CALIBRATION TYPE (WIGHT)
CALIBRATOR CONC. 1
CALIBRATOR POSITION 1
CALIBRATOR CONC. 2
CALIBRATOR POSITION 2
CALIBRATOR CONC. 3
CALIBRATOR POSITION 3
CALIBRATOR CONC. 4
CALIBRATOR POSITION 4
CALIBRATOR CONC. 5
CALIBRATOR POSITION 5
CALIBRATOR CONC. 6
CALIBRATOR POSITION 6
S1 ABS
K FACTOR
K 2 FACTOR
K 2 FACTOR
K 4 FACTOR
K 5 FACTOR
A FACTOR
B FACTOR
C FACTOR
SD LIMIT
DUPLICATE LIMIT
SENS.MLIMIT
S1 ABS LIMIT (L)
S1 ABS LIMIT (H)
ABS LIMIT
ABS LIMIT (D/I)
PRZ LIMIT
PRZ LIMIT (U/D)
PRZ (END POINT)
EXPECT. VALUE (L)
EXPECT. VALUE (H)
INSTR. FACTOR (A)
INSTR. FACTOR (B)
KEY SETTING

DESCRIPTION
HDL
1 POINT
0
10
35
0
0
0
660
505
30
300
*
*
0
0
0
0
0
0
LINEAR
0
0.00
*
@
*
0
0
0
0
0
0
0
0
0
10000
10000
10000
10000
10000
0
0
0
0.1
100
32000
-32000
32000
0
1
32000
U
35
*
*
1.0

0.0
POS. TECLADO

REVISO 00 - MAI/2006

SAC BioTcnica Ind e Com. Ltda.


Tel / Fax: +55 35 3214-4646 Varginha MG Brasil.
Site: www.biotecnica.ind.br / e-mail: sac@biotecnicaltda.com.br

Programaes de Automao Biotcnica


HITACHI 902
PRODUTO
CATLOGO
METODOLOGIA
N DETERMINAES

HDL COLESTEROLDIRETO
BT 10.006.00
ENZIMTICO
COLORIMTRICODIRETO
400

- O nmero de determinaes foi calculado


desconsiderando o volume morto do frasco de
reagente do equipamento.
- Recomenda-se a leitura das Instrues de Uso
(I.U) antes da utilizao do produto.
As informaes complementares para realizao do
teste esto descritas no Protocolo de Automao
ao lado:
PREPARAO DOS REAGENTES
R1: Reagente A - Pronto para uso
R3: Reagente B - Pronto para uso
CALIBRADORES
CONTROLES
Para avaliar o
desempenho do teste,
sugere-se a utilizao dos
controles Biotcnica:
Calibrador
HDL
Colesterol
- Quantinorm
(incluso no kit).
CAT BT 13.003.00
- Quantialt
CAT BT 13.004.00
OBSERVAES ESPECIAIS
Utilizar a concentrao que est expressa no rtulo do
calibrador.

@ Inserir a concentrao indicada no calibrador


Biotcnica Calibrador de HDL
* Parmetro definido pelo usurio

ESTE MARCA REGISTRADA DE SEUS FABRICANTES.

NO.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58

TEST
TEST NAME
ASSAY CODE (METHOD)
ASSAY CODE (TEST)
REACTION TIME
ASSAY POINT 1
ASSAY POINT 2
ASSAY POINT 3
ASSAY POINT 4
WAVELENGHT (SUB)
WAVELENGHT (MAIN)
SAMPLE VOLUME
R1 VOLUME
R1 POSITION
R1 BOTTLE SIZE
R2 VOLUME
R2 POSITION
R2 BOTTLE SIZE
R3 VOLUME
R3 POSITION
R3 BOTTLE SIZE
CALIBRATION TYPE (TYPE)
CALIBRATION TYPE (WIGHT)
CALIBRATOR CONC. 1
CALIBRATOR POSITION 1
CALIBRATOR CONC. 2
CALIBRATOR POSITION 2
CALIBRATOR CONC. 3
CALIBRATOR POSITION 3
CALIBRATOR CONC. 4
CALIBRATOR POSITION 4
CALIBRATOR CONC. 5
CALIBRATOR POSITION 5
CALIBRATOR CONC. 6
CALIBRATOR POSITION 6
S1 ABS
K FACTOR
K 2 FACTOR
K 2 FACTOR
K 4 FACTOR
K 5 FACTOR
A FACTOR
B FACTOR
C FACTOR
SD LIMIT
DUPLICATE LIMIT
SENS.MLIMIT
S1 ABS LIMIT (L)
S1 ABS LIMIT (H)
ABS LIMIT
ABS LIMIT (D/I)
PRZ LIMIT
PRZ LIMIT (U/D)
PRZ (END POINT)
EXPECT. VALUE (L)
EXPECT. VALUE (H)
INSTR. FACTOR (A)
INSTR. FACTOR (B)
KEY SETTING

DESCRIPTION
HDL-D
2 POINT END
0
10
17
35
0
0
700
600
3.0
225
*
*
0
0
0
75
*
*
LINEAR
0
0.00
*
@
*
0
0
0
0
0
0
0
0
0
10000
10000
10000
10000
10000
0
0
0
0.1
100
32000
-32000
32000
0
1
32000
U
35
*
*
1.0

0.0
POS. TECLADO

REVISO 00 - MAI/2006

SAC BioTcnica Ind e Com. Ltda.


Tel / Fax: +55 35 3214-4646 Varginha MG Brasil.
Site: www.biotecnica.ind.br / e-mail: sac@biotecnicaltda.com.br

Programaes de Automao Biotcnica


HITACHI 902
PRODUTO
CATLOGO
METODOLOGIA
N DETERMINAES

LDL COLESTEROLDIRETO
BT 10.015.00
DIRETO
130

- O nmero de determinaes foi calculado


desconsiderando o volume morto do frasco de
reagente do equipamento.
- Recomenda-se a leitura das Instrues de Uso
(I.U) antes da utilizao do produto.
As informaes complementares para realizao do
teste esto descritas no Protocolo de Automao
ao lado:
PREPARAO DOS REAGENTES
R1: Reagente A - Pronto para uso
R3: Reagente B - Pronto para uso
CALIBRADORES
CONTROLES
Para avaliar o
desempenho do teste,
sugere-se a utilizao dos
controles Biotcnica:
Calibrador
LDL
Colesterol
- Quantinorm
(incluso no kit).
CAT BT 13.003.00
- Quantialt
CAT BT 13.004.00
OBSERVAES ESPECIAIS
Utilizar a concentrao que est expressa no rtulo do
calibrador.

@ Inserir a concentrao indicada no calibrador


Biotcnica Calibrador de LDL
* Parmetro definido pelo usurio

ESTE MARCA REGISTRADA DE SEUS FABRICANTES.

NO.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58

TEST
TEST NAME
ASSAY CODE (METHOD)
ASSAY CODE (TEST)
REACTION TIME
ASSAY POINT 1
ASSAY POINT 2
ASSAY POINT 3
ASSAY POINT 4
WAVELENGHT (SUB)
WAVELENGHT (MAIN)
SAMPLE VOLUME
R1 VOLUME
R1 POSITION
R1 BOTTLE SIZE
R2 VOLUME
R2 POSITION
R2 BOTTLE SIZE
R3 VOLUME
R3 POSITION
R3 BOTTLE SIZE
CALIBRATION TYPE (TYPE)
CALIBRATION TYPE (WIGHT)
CALIBRATOR CONC. 1
CALIBRATOR POSITION 1
CALIBRATOR CONC. 2
CALIBRATOR POSITION 2
CALIBRATOR CONC. 3
CALIBRATOR POSITION 3
CALIBRATOR CONC. 4
CALIBRATOR POSITION 4
CALIBRATOR CONC. 5
CALIBRATOR POSITION 5
CALIBRATOR CONC. 6
CALIBRATOR POSITION 6
S1 ABS
K FACTOR
K 2 FACTOR
K 2 FACTOR
K 4 FACTOR
K 5 FACTOR
A FACTOR
B FACTOR
C FACTOR
SD LIMIT
DUPLICATE LIMIT
SENS.MLIMIT
S1 ABS LIMIT (L)
S1 ABS LIMIT (H)
ABS LIMIT
ABS LIMIT (D/I)
PRZ LIMIT
PRZ LIMIT (U/D)
PRZ (END POINT)
EXPECT. VALUE (L)
EXPECT. VALUE (H)
INSTR. FACTOR (A)
INSTR. FACTOR (B)
KEY SETTING

DESCRIPTION
LDL-D
2 POINT END
0
10
17
35
0
0
700
600
3.0
225
*
*
0
0
0
75
*
*
LINEAR
0
0.00
*
@
*
0
0
0
0
0
0
0
0
0
10000
10000
10000
10000
10000
0
0
0
0.1
100
32000
-32000
32000
0
1
32000
U
35
*
*
1.0

0.0
POS. TECLADO

REVISO 00 - MAI/2006

SAC BioTcnica Ind e Com. Ltda.


Tel / Fax: +55 35 3214-4646 Varginha MG Brasil.
Site: www.biotecnica.ind.br / e-mail: sac@biotecnicaltda.com.br

Programaes de Automao Biotcnica


HITACHI 902
PRODUTO
CATLOGO
METODOLOGIA
N DETERMINAES

MAGNSIO
BT 12.007.00
MAGON
166

- O nmero de determinaes foi calculado


desconsiderando o volume morto do frasco de
reagente do equipamento.
- Recomenda-se a leitura das Instrues de Uso
(I.U) antes da utilizao do produto.
As informaes complementares para realizao do
teste esto descritas no Protocolo de Automao
ao lado:
PREPARAO DOS REAGENTES
R1: Reagente - Pronto para uso
CALIBRADORES
CONTROLES
Para avaliar o
desempenho do teste,
sugere-se a utilizao dos
controles Biotcnica:
Autocal H
CAT BT 13.002.00
- Quantinorm
CAT BT 13.003.00
- Quantialt
CAT BT 13.004.00
OBSERVAES ESPECIAIS
No Aplicvel

@ Inserir a concentrao indicada no calibrador


Biotcnica Autocal H
* Parmetro definido pelo usurio

ESTE MARCA REGISTRADA DE SEUS FABRICANTES.

NO.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58

TEST
TEST NAME
ASSAY CODE (METHOD)
ASSAY CODE (TEST)
REACTION TIME
ASSAY POINT 1
ASSAY POINT 2
ASSAY POINT 3
ASSAY POINT 4
WAVELENGHT (SUB)
WAVELENGHT (MAIN)
SAMPLE VOLUME
R1 VOLUME
R1 POSITION
R1 BOTTLE SIZE
R2 VOLUME
R2 POSITION
R2 BOTTLE SIZE
R3 VOLUME
R3 POSITION
R3 BOTTLE SIZE
CALIBRATION TYPE (TYPE)
CALIBRATION TYPE (WIGHT)
CALIBRATOR CONC. 1
CALIBRATOR POSITION 1
CALIBRATOR CONC. 2
CALIBRATOR POSITION 2
CALIBRATOR CONC. 3
CALIBRATOR POSITION 3
CALIBRATOR CONC. 4
CALIBRATOR POSITION 4
CALIBRATOR CONC. 5
CALIBRATOR POSITION 5
CALIBRATOR CONC. 6
CALIBRATOR POSITION 6
S1 ABS
K FACTOR
K 2 FACTOR
K 2 FACTOR
K 4 FACTOR
K 5 FACTOR
A FACTOR
B FACTOR
C FACTOR
SD LIMIT
DUPLICATE LIMIT
SENS.MLIMIT
S1 ABS LIMIT (L)
S1 ABS LIMIT (H)
ABS LIMIT
ABS LIMIT (D/I)
PRZ LIMIT
PRZ LIMIT (U/D)
PRZ (END POINT)
EXPECT. VALUE (L)
EXPECT. VALUE (H)
INSTR. FACTOR (A)
INSTR. FACTOR (B)
KEY SETTING

DESCRIPTION
MAG
1 POINT
0
10
18
0
0
0
0
505
3.0
300
*
*
0
0
0
0
0
0
LINEAR
0
0.00
*
@
*
0
0
0
0
0
0
0
0
0
10000
10000
10000
10000
10000
0
0
0
0.1
220
32000
-32000
32000
0
1
32000
U
35
*
*
1.0

0.0
POS. TECLADO

REVISO 00 - MAI/2006

SAC BioTcnica Ind e Com. Ltda.


Tel / Fax: +55 35 3214-4646 Varginha MG Brasil.
Site: www.biotecnica.ind.br / e-mail: sac@biotecnicaltda.com.br

Programaes de Automao Biotcnica


HITACHI 902
PRODUTO
CATLOGO
METODOLOGIA
N DETERMINAES

PROTENA TOTAL
BT 10.009.00
COLORIMTRICO
833

- O nmero de determinaes foi calculado


desconsiderando o volume morto do frasco de
reagente do equipamento.
- Recomenda-se a leitura das Instrues de Uso
(I.U) antes da utilizao do produto.
As informaes complementares para realizao do
teste esto descritas no Protocolo de Automao
ao lado:
PREPARAO DOS REAGENTES
R1: Reagente - Pronto para uso
CALIBRADORES
CONTROLES
Para avaliar o
desempenho do teste,
sugere-se a utilizao dos
controles Biotcnica:
Autocal H
CAT BT 13.002.00
- Quantinorm
CAT BT 13.003.00
- Quantialt
CAT BT 13.004.00
OBSERVAES ESPECIAIS
No Aplicvel

@ Inserir a concentrao indicada no calibrador


Biotcnica Autocal H
* Parmetro definido pelo usurio

ESTE MARCA REGISTRADA DE SEUS FABRICANTES.

NO.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58

TEST
TEST NAME
ASSAY CODE (METHOD)
ASSAY CODE (TEST)
REACTION TIME
ASSAY POINT 1
ASSAY POINT 2
ASSAY POINT 3
ASSAY POINT 4
WAVELENGHT (SUB)
WAVELENGHT (MAIN)
SAMPLE VOLUME
R1 VOLUME
R1 POSITION
R1 BOTTLE SIZE
R2 VOLUME
R2 POSITION
R2 BOTTLE SIZE
R3 VOLUME
R3 POSITION
R3 BOTTLE SIZE
CALIBRATION TYPE (TYPE)
CALIBRATION TYPE (WIGHT)
CALIBRATOR CONC. 1
CALIBRATOR POSITION 1
CALIBRATOR CONC. 2
CALIBRATOR POSITION 2
CALIBRATOR CONC. 3
CALIBRATOR POSITION 3
CALIBRATOR CONC. 4
CALIBRATOR POSITION 4
CALIBRATOR CONC. 5
CALIBRATOR POSITION 5
CALIBRATOR CONC. 6
CALIBRATOR POSITION 6
S1 ABS
K FACTOR
K 2 FACTOR
K 2 FACTOR
K 4 FACTOR
K 5 FACTOR
A FACTOR
B FACTOR
C FACTOR
SD LIMIT
DUPLICATE LIMIT
SENS.MLIMIT
S1 ABS LIMIT (L)
S1 ABS LIMIT (H)
ABS LIMIT
ABS LIMIT (D/I)
PRZ LIMIT
PRZ LIMIT (U/D)
PRZ (END POINT)
EXPECT. VALUE (L)
EXPECT. VALUE (H)
INSTR. FACTOR (A)
INSTR. FACTOR (B)
KEY SETTING

DESCRIPTION
PRO
1 POINT
0
10
35
0
0
0
700
546
3.0
300
*
*
0
0
0
0
0
0
LINEAR
0
0.00
*
@
*
0
0
0
0
0
0
0
0
0
10000
10000
10000
10000
10000
0
0
0
0.1
100
32000
-32000
32000
0
1
32000
U
35
*
*
1.0

0.0
POS. TECLADO

REVISO 00 - MAI/2006

SAC BioTcnica Ind e Com. Ltda.


Tel / Fax: +55 35 3214-4646 Varginha MG Brasil.
Site: www.biotecnica.ind.br / e-mail: sac@biotecnicaltda.com.br

Programaes de Automao Biotcnica


HITACHI 902
PRODUTO
CATLOGO
METODOLOGIA
N DETERMINAES

TRIGLICRIDES
BT 10.010.00
ENZIMTICO
COLORIMTRICO
1666

- O nmero de determinaes foi calculado


desconsiderando o volume morto do frasco de
reagente do equipamento.
- Recomenda-se a leitura das Instrues de Uso
(I.U) antes da utilizao do produto.
As informaes complementares para realizao do
teste esto descritas no Protocolo de Automao
ao lado:
PREPARAO DOS REAGENTES
R1: Reagente - Pronto para uso
CALIBRADORES
CONTROLES
Para avaliar o
desempenho do teste,
sugere-se a utilizao dos
controles Biotcnica:
Autocal H
CAT BT 13.002.00
- Quantinorm
CAT BT 13.003.00
- Quantialt
CAT BT 13.004.00
OBSERVAES ESPECIAIS
No Aplicvel

@ Inserir a concentrao indicada no calibrador


Biotcnica Autocal H
* Parmetro definido pelo usurio

ESTE MARCA REGISTRADA DE SEUS FABRICANTES.

NO.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58

TEST
TEST NAME
ASSAY CODE (METHOD)
ASSAY CODE (TEST)
REACTION TIME
ASSAY POINT 1
ASSAY POINT 2
ASSAY POINT 3
ASSAY POINT 4
WAVELENGHT (SUB)
WAVELENGHT (MAIN)
SAMPLE VOLUME
R1 VOLUME
R1 POSITION
R1 BOTTLE SIZE
R2 VOLUME
R2 POSITION
R2 BOTTLE SIZE
R3 VOLUME
R3 POSITION
R3 BOTTLE SIZE
CALIBRATION TYPE (TYPE)
CALIBRATION TYPE (WIGHT)
CALIBRATOR CONC. 1
CALIBRATOR POSITION 1
CALIBRATOR CONC. 2
CALIBRATOR POSITION 2
CALIBRATOR CONC. 3
CALIBRATOR POSITION 3
CALIBRATOR CONC. 4
CALIBRATOR POSITION 4
CALIBRATOR CONC. 5
CALIBRATOR POSITION 5
CALIBRATOR CONC. 6
CALIBRATOR POSITION 6
S1 ABS
K FACTOR
K 2 FACTOR
K 2 FACTOR
K 4 FACTOR
K 5 FACTOR
A FACTOR
B FACTOR
C FACTOR
SD LIMIT
DUPLICATE LIMIT
SENS.MLIMIT
S1 ABS LIMIT (L)
S1 ABS LIMIT (H)
ABS LIMIT
ABS LIMIT (D/I)
PRZ LIMIT
PRZ LIMIT (U/D)
PRZ (END POINT)
EXPECT. VALUE (L)
EXPECT. VALUE (H)
INSTR. FACTOR (A)
INSTR. FACTOR (B)
KEY SETTING

DESCRIPTION
TGR
1 POINT
0
10
35
0
0
0
660
505
3.0
300
*
*
0
0
0
0
0
0
LINEAR
0
0.00
*
@
*
0
0
0
0
0
0
0
0
0
10000
10000
10000
10000
10000
0
0
0
0.1
100
32000
-32000
32000
0
1
32000
U
35
*
*
1.0

0.0
POS. TECLADO

REVISO 00 - MAI/2006

SAC BioTcnica Ind e Com. Ltda.


Tel / Fax: +55 35 3214-4646 Varginha MG Brasil.
Site: www.biotecnica.ind.br / e-mail: sac@biotecnicaltda.com.br

Programaes de Automao Biotcnica


HITACHI 902
PRODUTO
CATLOGO
METODOLOGIA
N DETERMINAES

URIA UV
BT 10.007.00
CINTICO
ENZIMTICO UV
833

- O nmero de determinaes foi calculado


desconsiderando o volume morto do frasco de
reagente do equipamento.
- Recomenda-se a leitura das Instrues de Uso
(I.U) antes da utilizao do produto.
As informaes complementares para realizao do
teste esto descritas no Protocolo de Automao
ao lado:
PREPARAO DOS REAGENTES
R1: Reagente A - Pronto para uso
R3: Reagente B - Pronto para uso
CALIBRADORES
CONTROLES
Para avaliar o
desempenho do teste,
sugere-se a utilizao dos
controles Biotcnica:
Autocal H
CAT BT 13.002.00
- Quantinorm
CAT BT 13.003.00
- Quantialt
CAT BT 13.004.00
OBSERVAES ESPECIAIS
No Aplicvel

@ Inserir a concentrao indicada no calibrador


Biotcnica Autocal H
* Parmetro definido pelo usurio

ESTE MARCA REGISTRADA DE SEUS FABRICANTES.

NO.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58

TEST
TEST NAME
ASSAY CODE (METHOD)
ASSAY CODE (TEST)
REACTION TIME
ASSAY POINT 1
ASSAY POINT 2
ASSAY POINT 3
ASSAY POINT 4
WAVELENGHT (SUB)
WAVELENGHT (MAIN)
SAMPLE VOLUME
R1 VOLUME
R1 POSITION
R1 BOTTLE SIZE
R2 VOLUME
R2 POSITION
R2 BOTTLE SIZE
R3 VOLUME
R3 POSITION
R3 BOTTLE SIZE
CALIBRATION TYPE (TYPE)
CALIBRATION TYPE (WIGHT)
CALIBRATOR CONC. 1
CALIBRATOR POSITION 1
CALIBRATOR CONC. 2
CALIBRATOR POSITION 2
CALIBRATOR CONC. 3
CALIBRATOR POSITION 3
CALIBRATOR CONC. 4
CALIBRATOR POSITION 4
CALIBRATOR CONC. 5
CALIBRATOR POSITION 5
CALIBRATOR CONC. 6
CALIBRATOR POSITION 6
S1 ABS
K FACTOR
K 2 FACTOR
K 2 FACTOR
K 4 FACTOR
K 5 FACTOR
A FACTOR
B FACTOR
C FACTOR
SD LIMIT
DUPLICATE LIMIT
SENS.MLIMIT
S1 ABS LIMIT (L)
S1 ABS LIMIT (H)
ABS LIMIT
ABS LIMIT (D/I)
PRZ LIMIT
PRZ LIMIT (U/D)
PRZ (END POINT)
EXPECT. VALUE (L)
EXPECT. VALUE (H)
INSTR. FACTOR (A)
INSTR. FACTOR (B)
KEY SETTING

DESCRIPTION
UUV
2 POINT RATE
0
5
10
17
0
0
700
340
3
240
*
*
0
0
0
60
*
*
LINEAR
0
0.00
*
@
*
0
0
0
0
0
0
0
0
0
10000
10000
10000
10000
10000
0
0
0
0.1
100
32000
-32000
32000
0
1
32000
D
35
*
*
1.0

0.0
POS. TECLADO

REVISO 00 - MAI/2006

SAC BioTcnica Ind e Com. Ltda.


Tel / Fax: +55 35 3214-4646 Varginha MG Brasil.
Site: www.biotecnica.ind.br / e-mail: sac@biotecnicaltda.com.br

Programaes de Automao Biotcnica


HITACHI 902
PRODUTO
CATLOGO
METODOLOGIA
N DETERMINAES

PROTENA URINRIA
BT 10.016.00
COLORIMTRICO

- O nmero de determinaes foi calculado


desconsiderando o volume morto do frasco de
reagente do equipamento.
- Recomenda-se a leitura das Instrues de Uso
(I.U) antes da utilizao do produto.
As informaes complementares para realizao do
teste esto descritas no Protocolo de Automao
ao lado:
PREPARAO DOS REAGENTES
R1: Reagente - Pronto para uso
CALIBRADORES
CONTROLES
Para avaliar o
Padro de Protena desempenho do teste,
(incluso no kit)
sugere-se a utilizao dos
Controles Biotcnica:
- Controle Urinrio CAT BT
13.005.00
OBSERVAES ESPECIAIS
No Aplicvel

@ Inserir a concentrao indicada no calibrador


Biotcnica de Protena Urinria
* Parmetro definido pelo usurio

ESTE MARCA REGISTRADA DE SEUS FABRICANTES.

NO. TEST
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58

DESCRIPTION

TEST NAME
ASSAY CODE (METHOD)
ASSAY CODE (TEST)
REACTION TIME
ASSAY POINT 1
ASSAY POINT 2
ASSAY POINT 3
ASSAY POINT 4
WAVELENGHT (SUB)
WAVELENGHT (MAIN)
SAMPLE VOLUME
R1 VOLUME
R1 POSITION
R1 BOTTLE SIZE
R2 VOLUME
R2 POSITION
R2 BOTTLE SIZE
R3 VOLUME
R3 POSITION
R3 BOTTLE SIZE
CALIBRATION TYPE (TYPE)
CALIBRATION TYPE (WIGHT)
CALIBRATOR CONC. 1
CALIBRATOR POSITION 1
CALIBRATOR CONC. 2
CALIBRATOR POSITION 2
CALIBRATOR CONC. 3
CALIBRATOR POSITION 3
CALIBRATOR CONC. 4
CALIBRATOR POSITION 4
CALIBRATOR CONC. 5
CALIBRATOR POSITION 5
CALIBRATOR CONC. 6
CALIBRATOR POSITION 6
S1 ABS
K FACTOR
K 2 FACTOR
K 2 FACTOR
K 4 FACTOR
K 5 FACTOR
A FACTOR
B FACTOR
C FACTOR
SD LIMIT
DUPLICATE LIMIT
SENS.MLIMIT
S1 ABS LIMIT (L)
S1 ABS LIMIT (H)
ABS LIMIT
ABS LIMIT (D/I)
PRZ LIMIT
PRZ LIMIT (U/D)
PRZ (END POINT)
EXPECT. VALUE (L)
EXPECT. VALUE (H)
INSTR. FACTOR (A)
INSTR. FACTOR (B)
KEY SETTING

REVISO 00 - MAI/2006

SAC BioTcnica Ind e Com. Ltda.


Tel / Fax: +55 35 3214-4646 Varginha MG Brasil.
Site: www.biotecnica.ind.br / e-mail: sac@biotecnicaltda.com.br

PRO-U
1 POINT
0
5
17
0
0
0
700
600
6
300
*
*
0
0
0
0
0
0
LINEAR
0
0.00
*
@
*
0
0
0
0
0
0
0
0
0
10000
10000
10000
10000
10000
0
0
0
0.1
100
32000
-32000
32000
0
1
32000
U
35
*
*
1.0
0.0
POS. TECLADO

Você também pode gostar