Moduflow™ Series

Low Pressure Filters

36
Moduflow™ Series
Applications
•  Power Unit Fabrication A wide variety of visual and electrical
indicators allows you to know ex-
•  Off-line Filter Loops actly when the element needs to be
serviced. There is even a “no
•  Mobile Equipment
element” indicator that can sense
The Moduflow filter is widely when there is not an element in-
considered the most versatile filter stalled in the filter.
available on the market.
From top to bottom, the Moduflow
The patented end cap minimizes filter series provides the high
turbulence and pressure loss level of filtration and long term
through the filter, improving system dependability so vital to today’s
performance. hydraulic systems.

The newly designed closed bottom


elements for the RFP and ILP models
insures all contamination remains
trapped within the element as the
filter is serviced.

Parker’s new patented Moduflow


element was designed with built-in
diverter and bypass valve, to meet
your application needs.

Mounting / Porting Styles
RFP ILP
Return Filter In-Line Filter

FILTER
HEAD
RETURN
OUT IN

BOWL
BOWL
TANK

OUTLET
PORT

37
Moduflow™ Series
Features

Flanges Cover
- NPT or - Slotted for quick
SAE ¾” to 2” release
- Lightweight - Lightweight
aluminum aluminum

Indicators Bowl
- Visual or electrical - Single or double
- Mounted on either side length
- Standard “no element” - Durable steel
indication construction

Bypass Element
(not visible) (not visible)
- Integral 35 psi - Available in high performance
bypass replaced Microglass media
with every - Single or double length
element change

Feature Advantage Benefit


•• Top access element service •• Oil remains in housing •• No Spills
•• Quicker elements change •• Reduced maintenance costs
•• Slotted cover •• Quick release cover •• Reduced maintenance cost
•• Cap screws remain in housing •• No loose parts to lose
•• Closed bottom elements •• Removes all contaminant during •• No downtime contamination from
element service servicing
•• Visual or electrical indicators •• Know exactly when to service •• Helps prevent bypass condition
elements •• No premature disposal
•• Flange face ports •• Flexible mounting (3/4” to 2”) •• Easy plumbing to your system

38
Moduflow™ Series
RFP-1 and ILP-1 Element Performance
Efficiency Capacity
Beta Rating Efficiency % PSID BAR
10000 50
2Q
5Q
2Q 10Q 3.0
5Q
20Q
40
1000 99.9 2.5
10Q

30 2.0
200 99.5
100 99.0
20Q 1.5
20
20 95.0
1.0

10
0.5
2 50.0

0 0.0
0 4 8 12 16 20 0 20 40 60 80 100
Micron Size (c) Capacity grams

Multipass tests run @ 40 gpm to 50 psid terminal - 5mg/L BUGL

Flow vs. Pressure Loss


LPM LPM
0 50 100 150 200 250 300 350 0 50 100 150 200 250 300 350
20 20
150SUS
150SUS
02Q 1.2 Empty Housing 0.6
16 16
05Q 1.0 0.5
12 12
0.8 0.4
PSID

BAR

BAR
PSID

8 0.6 0.3
8
10Q
20Q 0.4 0.2
4 4
0.2 2” SAE flange 0.1

0 0.0 0 0.0
0 20 40 60 80 100 0 20 40 60 80 100
GPM GPM

39
Moduflow™ Series
RFP-2 and ILP-2 Element Performance
Efficiency Capacity
Capacity
Beta Rating Efficiency % PSID BAR
10000 50
2Q
5Q
10Q 3.0
2Q 5Q 20Q
40
1000 99.9 2.5
10Q

30 2.0
200 99.5
100 99.0
20Q 1.5
20
20 95.0
1.0

10
0.5
2 50.0

0 0.0
0 4 8 12 16 20 0 20 40 60 80 100 120 140 160
Micron Size (c) Capacity grams

Multipass tests run @ 80 gpm to 50 psid terminal - 5mg/L BUGL

Flow vs. Pressure Loss


LPM LPM
0 100 200 300 400 500 0 100 200 300 400 500
20 10
150SUS 150SUS
1.2 Empty Housing 0.6
16 8
1.0 0.5

12 6
0.8 0.4
PSID
PSID

BAR
BAR

02Q
05Q 0.6 0.3
8 4
10Q 0.4 2” SAE flange 0.2
20Q
4 2
0.2 0.1

0 0.0 0 0.0
0 25 50 75 100 125 150 0 25 50 75 100 125 150
GPM GPM

40
Moduflow™ Series
Specifications: RFP, ILP
Pressure Ratings:
Maximum Allowable Operating Pressure
(MAOP): 200 psi (13.8 bar) Dimensions: mm/inch
Design Safety Factor: 2:1 Model A B C D
Rated Fatigue Pressure: 150 psi (10.3 bar)
RFP-1 with 68.3 _ 390.0 117.1
Element Burst Rating: 70 psid (4.8 bar) optional 2” fitting 2.69 15.37 4.61

Filter Materials: RFP-1 without 65.0 378.0 _ 114.0


optional 2” fitting 2.56 14.87 4.50
Head, Cover, Flanges: die cast aluminum
Bowl: steel RFP-2 with 68.3 _ 625.0 117.1
optional 2” fitting 2.69 24.61 4.61
Operating Temperatures:
Nitrile: -40°F to 225°F (-40°C to 107°C) RFP-2 without 68.3 612.0 _ 114.0
Fluorocarbon: -15°F to 275°F (-26°C to 135°C) optional 2” fitting 2.69 24.11 4.50

Weight (approximate): ILP-1 65.0 336.0 N/A 117.1


Single: 20 lbs. (9.1 kg) 2.56 13.24 4.61
Double: 25 lbs. (11.3 kg) ILP-2 68.3 618.0 N/A 117.1
2.69 24.32 4.61
Indicators:
Visual (optional)
Electrical (optional) 15A @ 250VAC  / .5A @ 125 VDC
Electrical (“D” option) 5A @ 250VAC  / 3A @ 28 VDC Drawings are for reference only.
Contact factory for current version.
Color Coding:
White (normally closed)
Red (normally open)
Black (common)
OPTIONAL 3-PIN
MALE RECEPTACLE MINIMUM ELEMENT
ILP OUTLET REMOVAL CLEARANCE
216.0
Single: 345.9 8.5
13.62
Double: 482.6 168.0
19.00 6.6
108.0
4.26

A
156.0
6.13
78.7
3.1

OPTIONAL
IL & RF INLET TANK FLANGE
196.3 OPTIONAL
7.7
C B MOUNTING
BRACKET

Linear Measure: millimeter


OPTIONAL PORT FLANGE inch
77.8
3.062
38.9 30.2
1.53 1.19 12.7
0.50
(99 OPTION)
RFP-1 OUTLET

RFP OUTLET 69.9 2-11½” NPTF


2.75 OPTIONAL
42.9 FITTING
1.68
21.3 D

41
Moduflow™ Series Drawings are for reference only.
Contact factory for current version.

Specifications: DILP 3.3


.013
Pressure Ratings:
Maximum Allowable Operating Pressure
(MAOP): 200 psi (13.8 bar) 116.8
79.0
4.60
Design Safety Factor: 2:1 3.11
Rated Fatigue Pressure: 150 psi (10.3 bar)
76.2
3.00
Element Burst Rating: 70 psid (4.8 bar)
½-13 SHCS
Filter Materials: ¼-18 NPT TORQUE
Diverter Valve Assembly: die cast aluminum DRAIN VENT 32-38 FT-LB
CONNECT
Check Valve Assembly: die cast aluminum TO TANK 173.0
6.81 330.2 SINGLE
Filter Assembly: see IL2 specifications 13.0

Operating Temperatures: 617.5


DOUBLE
24.31
Nitrile: -40°F to 225°F (-40°C to 107°C)
Fluorocarbon: -15°F to 275°F (-26°C to 135°C)
110.5
Weight (approximate): 4.61
Single: 55 lbs. (24.9 kg) / Double: 65 lbs. (29.5 kg)
Indicators: Linear Measure: millimeter
inch
Visual (optional)
Electrical (optional) 15A @ 250VAC / .5A @ 125 VDC
Electrical (“D” option) 5A @ 250VAC  / 3A @ 28 VDC
467.0
Color Coding: 18.38
White (normally closed)
AIR BLEED
Red (normally open) EACH FILTER
30.2
Black (common) 1.19
FILTER SCHEMATIC OPTIONAL
FLANGE
OUTLET
OUTLET 402.8
345.9 15.86
13.62
FILTER FILTER 177.8
INLET
7.00
BYPASS BYPASS

DRAIN OPTIONAL MECHANICAL INDICATOR


INLET VENT

BOTH CHECK VALVES MOVE SAME DIRECTION


Approximate handle torque required for changeover. Typical Flow/Pressure Curves For Duplex Valves
1.75
25

30
BAR

1.5 (Add to differential pressure of filter assembly


20 for total duplex pressure differential)
1.25
*Diverter/check valves combined S
Torque (Ft-Lbs)

SU
20
DIFF . PRESSURE

1 15
00 SUS
30 0
20
0.75
10
10 0.5

5
0.25
PSID

0 0
0 100 200 300 0 10 20 30 40 50 60 70 80 90 100
GPM FLOW LP M

System Pressure (psi) 0 25 50 75 100 125 150 175 200 225 250 275 300 325 375

42
Moduflow™ Series
Specifications
For return line applications (RFP),
the fluid returning to the reservoir Check Valve Flow/Pressure Drop
holds the check valve open. When
the system is shut down, the check 3.0
valve closes automatically. *Check valve pressure drop must be added
to assembly pressure drop to get total
2.5

2.0

Pressure Loss (psid)

1.5

1.0

0.5

0.0
0 10 20 30 40 50 60 70 80 90 100
Flow (GPM)

Linear Measure: millimeter


inch

RFP
SINGLE ELEMENT
452.1
17.8

RFP
DOUBLE ELEMENT
688.3
27.1

Drawings are for reference only.


Contact factory for current version.

117.1 MAX. O.D.


4.61 OVER WELD
(RFP & DOUBLE LENGTH)

43
Moduflow™ Series
Specifications
Lower Cost than many
single unit filters.

Moduflow™ Manifold
Extended Filter Range
Use Model MM Manifold to handle Multiple Uses
return line flows up to 130 gpm. Although designed for manifold ModuFlow filters, the Model MM can be TM

•• Rated static pressure: 300 psi used in a variety of applications which require:
•• Typical burst pressure: 900 psi •• Splitting flow between components
•• Easily mounted on
ModuFlow™ Such applications are frequently encountered on mobile equipment,
machine tools, and large lubricating
High Flows At Low Cost systems. In such applications, use of a manifold can often reduce total piping
The model MM manifold is and installation costs.
designed to extend the flow range of
Moduflow Filters when operating
TM

with 10 Micron and finer filter Proven Reliability


media. When mounted to a pair of The rugged design of the Model MM manifold has been proven in
RFP-2 or ILP-2 filters, this manifold demanding mobile equipment applications, At the factory, we have cycle
will allow flows up to 130 gpm in tested the Model MM through the full range of rated flow and pressure to
return lines (15 fps velocity). insure reliable service.
Note: The Model MM manifold is not
applicable to suction lines due to its Parker Filter Division maintains the same high standards in delivery,
pressure drop characteristics. quality, and service. Considering this, plus features, flexibility, price, and
performance, the Model MM manifold is a valuable addition to your fluid
When used with two Moduflow TM power component list.
filters, the total cost is often less than
a single unit filter rated for 130 gpm
flow. Tank-top mounted (Model
RFP) filters will require only one FLOW/PRESSURE CURVE
manifold on the filter inlet pports.
In-line mounted (Model ILPav) 0.7 TYPICAL FLOW/PRESSURE CURVES FOR MODEL MM
filters will require two manifolds, 10
38B6

one on the inlet and one on the 0.6

outlet ports.
(BAR )

8
US

0.5
0S
20

0.4 6
DIFF. PRESS.

0.3
4

0.2
2
(PSI)

0.1

0
0 0 25 50 75 100 125 150 175 200 225 250

(GPM) INLET FLOW (LPM)


0 75 150 225 300 375 450 525 600 675 750 825 900

44
Moduflow™ Series
Specifications

Manifold Specifications
Rated Static Pressure, max.: Housing Material: Screws & O-Rings Separately:
20.7 bar (300 psi) ANSI 356-T6 cast aluminum Inlet & outlet screws (12 required):
Typical Burst Pressure: P/N 900228
62.1 bar (900 psi) Approximate Shipping Weight:
Operating Temperature 3.6 kg (8 lbs) Outlet port o-rings (2 required):
(Nitrile seals): -40ºC to 121ºC Nitrile: P/N N72228
(-40ºF to 250ºF) Porting: See Options Below Fluorocarbon: P/N V92228

INSTALLATION DIMENSIONS
12.7mm
177.8mm
.50 88.9mm
88.9mm 7.00
3.50
3.50

155.6mm
6.125
How to order manifolds
Part Number Description
926466 Moduflow Manifold
(TORQUE SCREWS
TO 32-38 FT-LBS)

* Tank-top mounted RFP filters will 77.8mm


3.062
77.8mm
42.9mm 3.062
require one manifold on filter inlets: 1.688 42.9mm
1.688
in-line mounted ILP filters will 66.8mm
2.63 (TORQUE SCREWS
require two manifolds on both inlets TO 32-38 FT-LBS)

and outlets. 66.8mm


2.63

VIEW AT C-C

STANDARD OUTLET, 2 PLS


273.8mm
2-0 SAE 4-BOLT FLANGE
10.78
WITH 2-228 O-RING GROOVE

TOLERANCES
To one decimal place: 3.0mm
0.12
Drawings are for reference only.
To two decimal places: 0.8mm
Contact factory for current version. C C
0.03

To three decimal places: 0.4mm


0.015

Linear Measure: Millimeter


Inch

45
Moduflow™ Series
Linear Measure: millimeter
Accessories inch

OPTIONAL MOUNTING BRACKET (924904) “M” OPTION-VISUAL INDICATOR,


161. 5 NO ELEMENT WARNING
6.5
8.7
0.344 122. 9
DIA. THR U 4.84
PLACES

60 7.9
TYP 0.31

114. 3
4.500

R
114. 3 6.44
4.500 0.25

13.5
0.531
DIA. THR U “E” OPTION-ELECTRICAL INDICATOR
4 PLA CES 926643

114.3
4.500 13.5
.531 DIA. THRU TYP.
57.2
2.25 41.1
1.62

25.4
1.00

Black - Common
White - Normally Closed

Parts List Red - Normally Open

Flange Kits (flange, 4 bolts, o-ring)


Part Number
Size Code Nitrile Fluorocarbon
¾ inch NPTF YB 924788 926013
1 inch NPTF YC 924787 926012
1¼ inch NPTF YD 924912 926004
1½ inch NPTF YE 924786 926011
2 inch NPTF YF 924785 926010
SAE - 12 YM 924784 926009
SAE - 16 YN 924783 926008
SAE - 20 YO 924913 926005
SAE - 24 YP 924782 926007
BLANK FLANGE — 924781 926006 Drawings are for reference only.
Contact factory for current version.

46
Moduflow™ Series
Parts List
Index Description Part No. Quantity Index Description Part No. Quantity
1 Screws, Nameplate 900028 2 12 Check Valve Assy. 925120 1
2 Name Plate, Unstamped 920928 1 13 Flange Kits Refer to 1
O-Ring Table 1
3 Cover Screws, 5/16-18 UNC x 1” 926633 6 V72228
4 Bowl Screws, 5/16-18 UNC x 1” 926633 6 14 Plug Kit, Fastener, self-sealing, 925974 2
o-ring seal included with fastener
5 Cover, Without nameplate 924634 1
15 Indicator Electrical Optional
6 Cover O-Ring 35 psid 926643
Nitrile N72350 1 35 psid, 3-pin male receptacle 926753
Fluorocarbon V72350 1 Gasket 926126 2
7 Bowl O-Ring O-Ring V72010 2
Nitrile N72251 1 16 Indicator Visual Optional
Fluorocarbon V72251 1 35 psid 4-band 926748
Bracket, Inline mounting 924904 Optional
8 Element Seal Indicator Kit, Remote mount 924894 Optional
Nitrile 937410 1
Fluorocarbon 937411 1 17 Changeover Valve Assy., Duplex 926758 Optional
9 Element Refer to 1
Table 18 Check Valve Assy., Duplex 926757 Optional

10 Head, Machined only 1 Not Drain Plug, SAE-24 for RFP model
2” SAE Flange 925972 1 Shown Nitrile 909992 1
1½”SAE Flange 926146 1 Fluorocarbon 928363 1
1½” NPTF 925949 Not Check Valve Assy., Duplex N72265 1
Shown
11 Bowl, Select desired model 1
ILP-1 925916
ILP-2 924816
RFP-1 937626
RFP-1 with 2 inch NPTF fitting 924676 Filter Assembly
RFP-2 937627
RFP-2 with 2 inch NPTF fitting 924818
11 12
Exploded View
4
7

10
17 18

5 8 9
3 6

2
1

14

13 15
16 Drawings are for reference only.
Contact factory for current version.

47
Moduflow™ Series
Low pressure filters
How To Order
Select the desired symbol (in the correct position) to construct a model code.

Example:

BOX 1 BOX 2 BOX 3 BOX 4 BOX 5 BOX 6 BOX 7 BOX 8

ILP 1 10Q B MP 35 Y9Y9 1

BOX 1: Filter Series BOX 5: Indicator BOX 7: Ports


Symbol Description Symbol Description Symbol Description
Return-lin filter, inlet on side P Plugged Ports Filter Inlet Symbol/ Outlet Symbol/
RFP
outlet on bottom Model Description Description
Visual indicator w/
ILP In-line filter M
“no element” warning Y9 2” flange face 99 No fitting

DILP In-line filter Electrical indicator w/ SAE-24


E RFP P9 F9 2” NPTF
12” leads integral threads

BOX 2: Element Length Electrical indicator w/ 3-pin male F8


External check
D valve
quick dsconnect
Symbol Description
Note: First letter of indicator code = left side Y9 2” flange face Y9 2” flange face
1 Single of filter head when looking into inlet with bowl ILP
SAE-24 SAE-24
down; second letter = right side of filter head P9 P9
integral threads integral threads
2 Double when looking into inlet with bowl down.
DILP Y9 2” flange face Y9 2” flange face
BOX 3: Media Code BOX 6: Bypass
Symbol Description Symbol Description BOX 8: Options
02Q Microglass, 2 micron 35 35 psid (2.4 bar) Symbol Description
05Q Microglass, 5 micron 1 None
10Q Microglass, 10 micron
1. First pair of symbols denotes inlet for all filter
20Q Microglass, 20 micron styles; second pair of symbols denotes outlet.
2. Four symbols required: two for inlet, two for
WR Water Removal outlet.
3. Unused ports in filters come plugged with a
blank flange.
BOX 4: Seals 4. See Flange Kits table for port flange options.
Flange Kits are ordered separately.
Symbol Description
B Nitrile
Please note the bolded options reflect
E EPR standard options with a reduced lead time.
V Fluorocarbon

RFP / ILP /  DILP Replacement Elements


Nitrile Seals Fluorocarbon Seals

Media Single Double Single Double

02Q 937393Q 937397Q 937401Q 937405Q


05Q 937394Q 937398Q 937402Q 937406Q
10Q 937395Q 937399Q 937403Q 937407Q
20Q 937396Q 937400Q 937404Q 937408Q
WR 940733 940734 940735 940736

48
Moduflow™ TFP Series
Bowl-less Design
3.24 [82.4]

INLET FLANGE
KIT ACCESSORY

1.19 [30.2]

5/16-18 UNC HEX HEAD


COVER SCREW
6.62 [168.1] 3.06 [77.8]
TORQUE TO 16-20 FT-LBS
COVER

3.18 [80.7]
2.47 [62.7]
INLET

2.47 [63.0] .50


TANK MOUNTING
SURFACE
(.010” MIN. FLATNESS
REQUIRED FOR SEAL)

INLET
CONFIGURATION: 4.70 [119.4]
FLANGE SEAL
2” SAE FLANGE FACE TANK HOLE RECOMMENDED
P/N N72251
(REF. SAE J518 CODE 61) (5.00 [127.0] MAX ALLOWED)
(SIZE 2-251)
WITH INTEGRAL
SAE-24 (1 7/8-12 UN-2B
THREAD)
O-RING BOSS PORT
(REF. SAE J1926/1)

12.19 [309.6] TFP-1


21.46 [545.1] TFP-2

.50 [12.7] MIN


INSTALLATION
TANK BOTTOM
CLEARANCE 45°
SURFACE

BYPASS
FLOW .415 DIA TANK
MOUNT HOLES BOTTOM VIEW
4-TOTAL ON 6.750
BOLT CIRCLE

Features Advantages
Shorter port-to-port distance. Provides a smaller footprint and reduced weight.

Direct tank mount capability eliminates need for adaptor Aluminum die cast head reduces weight and direct
flanges and bowl. tank mount flange reduces installation time and cost.
Standard head incorporates 2” SAE flange face with Enables one common head to be used. Simplifies
integral SAE-24 port configuration. ordering model code.
Filter head and element 2-piece construction requires Reduces assembly cost by 25%.
no filter bowl.
Patented element design with integral bypass valve and Ensures all contaminants remain captured during
inside to out flow path. service. New bypass valve with each element ensures
operation reliability.

49
Moduflow™ TFP Series
Low pressure filters
How To Order
Select the desired symbol (in the correct position) to construct a model code.

Example:

BOX 1 BOX 2 BOX 3 BOX 4 BOX 5 BOX 6 BOX 7 BOX 8

TFP 1 10Q B MP 35 C32 1

BOX 1: Filter Series BOX 4: Seals BOX 6: Bypass


Symbol Description Symbol Description Symbol Description
TFP Return-line filter B Nitrile 35 35 psid (2.4 bar)
Return-line filter anodized for E EPR
TFPW BOX 7: Ports
HWHC fluid
V Fluorocarbon
Symbol Description
BOX 2: Element Length
2” SAE flange face
C32
Symbol Description BOX 5: Indicator SAE-24 combination inlet port
1 Single Symbol Description
BOX 8: Options
2 Double P Plugged Ports
Symbol Description
Visual indicator w/
BOX 3: Media Code M 1 None
“no element” warning
Symbol Description Electrical indicator w/
E Please note the bolded options reflect
12” leads
02Q Microglass, 2 micron standard options with a reduced lead time.
Electrical indicator w/ 3-pin
05Q Microglass, 5 micron D
male quick dsconnect
10Q Microglass, 10 micron Note: First letter of indicator code = left side
of filter head when looking into inlet with bowl
20Q Microglass, 20 micron down; second letter = right side of filter head
when looking into inlet with bowl down.
WR Water Removal

Replacement Elements
TFP-1 TFP-2
Media Ethylene Media Ethylene
Nitrile Fluorocarbon Nitrile Fluorocarbon
Propylene Propylene
02Q 937393Q 937401Q 937671Q 02Q 937397Q 937405Q 937675Q
05Q 937394Q 937402Q 937672Q 05Q 937398Q 937406Q 937676Q
10Q 937395Q 937403Q 937673Q 10Q 937399Q 937407Q 937677Q
20Q 937396Q 937404Q 937674Q 20Q 937400Q 937408Q 937678Q
WR 940733 940735 N/A WR 940734 940736 N/A

50