REFORÇO DE VIGAS À FLEXÃO

COM LAMINADOS FRP - ACI 440.2R 17


Obra: Endereço
Data: 01/01/2021
*Preencher dados em azul
DADOS DA VIGA DADOS DOS MATERIAIS DADOS DA FIBRA
L≔7 m fck ≔ 35 MPa tf ≔ 1.6 mm Espessura
bw ≔ 30 cm fyd ≔ 434 MPa wf ≔ 50 mm Largura
h ≔ 60 cm Es ≔ 210 GPa ffuk ≔ 3100 MPa Resistência Última
d' ≔ 5 cm αE ≔ 1 Ef ≔ 165000 MPa Módulo de Elasticidade
hlaje ≔ 0 cm εcu ≔ 0.0035 εfuk ≔ 0.017 Deformação Última
DADOS DA ARMADURA nf ≔ 3 Camadas de Fibra
nØ ≔ 3
Ø ≔ 25 mm
CONSTANTES CARREGAMENTOS
ØACI ≔ 0.9 ψf ≔ 0.85 CE ≔ 0.95
tonnef tonnef
ACI 440.2R - TABLE 9.4 wPP ≔ bw ⋅ h ⋅ 2.5 ――― = 0.45 ―――
3
m m

tonnef
wPP2 ≔ 0 ――― Peso próprio
m adicional

tonnef
wDL ≔ 1.1 ――― Permanentes
m

tonnef
wLL ≔ 2.3 ――― Acidentais
m

CARREGAMENTOS COMBINADOS

tonnef
ws ≔ ⎛⎝wPP + wPP2⎞⎠ + wDL + wLL = 3.85 ――― Carregamento em serviço
m

tonnef
wlim ≔ 1.1 ⋅ ⎛⎝⎛⎝wPP + wPP2⎞⎠ + wDL⎞⎠ + 0.75 ⋅ wLL = 3.43 ――― Carregamento limite sem
m reforço

tonnef
wu ≔ 1.2 ⋅ ⎛⎝⎛⎝wPP + wPP2⎞⎠ + wDL⎞⎠ + 1.6 ⋅ wLL = 5.54 ――― Carregamento último
m

⎛⎝⎛⎝wPP + wPP2⎞⎠ + wDL⎞⎠ ⋅ L 2


MDL ≔ ――――――――= 9.494 tonnef ⋅ m Momento Permanente
8

⎛⎝wLL⎞⎠ ⋅ L 2
MLL ≔ ―――― = 14.088 tonnef ⋅ m Momento Acidental
8

⎛⎝ws⎞⎠ ⋅ L 2
MELS ≔ ―――= 23.581 tonnef ⋅ m Momento em serviço
8

⎛⎝wlim⎞⎠ ⋅ L 2
Mlim ≔ ―――― = 21.009 tonnef ⋅ m Momento limite sem reforço
8

⎛⎝wu⎞⎠ ⋅ L 2
Mu ≔ ―――= 33.933 tonnef ⋅ m Momento último
8

thiagoaramac@gmail.com 1
61 99951-9992
REFORÇO DE VIGAS À FLEXÃO
COM LAMINADOS FRP - ACI 440.2R 17
Obra: Endereço
Data: 01/01/2021
CÁLCULOS PRELIMINARES
Ac ≔ bw ⋅ h = 1800 cm 2 df ≔ h - hlaje = 60 cm
π ⋅ Ø2
As ≔ nØ ――― = 14.726 cm 2 d ≔ h - d' = 550 mm
4
Af ≔ nf ⋅ tf ⋅ wf = 240 mm 2 ffu ≔ CE ⋅ ffuk = 2945 MPa

Ecs ≔ αE ⋅ 5600 ⋅ ‾‾‾‾‾‾‾


fck ⋅ MPa = 33130.047 MPa εfu ≔ CE ⋅ εfuk = 0.0162
As ⋅ fyd
β1 ≔ if fck ≤ 28 MPa = 0.8 LNi ≔ ―――――― = 89.512 mm
‖ 0.85 β1 ⋅ ⎛⎝0.85 ⋅ fck ⋅ bw⎞⎠

else if fck ≤ 55 MPa Es As
‖ ηs ≔ ―― = 6.339 ρs ≔ ――= 0.0089
⎛ fck ⎞ Ecs bw ⋅ d
‖ 0.05 ⋅ ⎜――- 28⎟
‖ ⎝ MPa ⎠
‖ 0.85 - ―――――― Ef
ηf ≔ ―― = 4.98
Af
ρf ≔ ――= 0.0015
‖ 7
Ecs bw ⋅ d
else
‖ 0.65 Ef

ηfs ≔ ― = 0.786
Es

RESISTÊNCIA DA VIGA SEM REFORÇO CONFORME ACI 318-19

⎛ ⎛ β1 ⋅ LNi ⎞⎞
ØMn_i ≔ ØACI ⋅ ⎜0.85 ⋅ fck ⋅ β1 ⋅ LNi ⋅ bw ⋅ ⎜d - ――― ⎟⎟ = 30.16 tonnef ⋅ m
⎝ ⎝ 2 ⎠⎠

DEFORMAÇÃO INICIAL NO CONCRETO

‾‾‾‾‾‾‾‾‾‾‾‾‾‾
2 ⎛ k⎞
k≔ ⎛⎝ρs ⋅ ηs⎞⎠ + 2 ⋅ ρs ⋅ ηs - ρs ⋅ ηs = 0.2845 j ≔ ⎜1 - ―⎟ = 0.905
⎝ 3⎠

bw ⋅ k 2 ⋅ j ⋅ d 3
Icr ≔ ―――― = 182866.983 cm 4
2

MDL ⋅ ((h - k ⋅ d)
εbi ≔ ―――――= 0.000682
Icr ⋅ Ecs

mm
N.E.T ≔ nf ⋅ Ef ⋅ tf ⋅ ―― = 792000
N

km ≔ if N.E.T ≤ 180000 = 0.117


‖ 1 ⎛ N.E.T ⎞
‖ ――― ⋅ ⎜1 - ――― ⎟
‖‖ 60 ⋅ εfu ⎝ 360000 ⎠
else
‖ 1 90000
‖ ――― ⋅ ―――
‖‖ 60 ⋅ εfu N.E.T

thiagoaramac@gmail.com 2
61 99951-9992
REFORÇO DE VIGAS À FLEXÃO
COM LAMINADOS FRP - ACI 440.2R 17
Obra: Endereço
Data: 01/01/2021
CÁLCULO DA LINHA NEUTRA

c = 146.686 mm
⎛ ‾‾‾‾‾‾‾‾‾‾
fck ⎞
εfd ≔ min ⎜0.9 ⋅ εfu , 0.41 ⋅ ――――⎟ = 0.00273
⎜ tf ⎟
⎜ nf ⋅ Ef ⋅ ―― ⎟
⎝ mm ⎠
⎛ ⎛h-c⎞ ⎞
εfe ≔ min ⎜0.003 ⋅ ⎜―― ⎟ - εbi , εfd⎟ = 0.00273
⎝ ⎝ c ⎠ ⎠

⎛ c ⎞
εc ≔ ⎛⎝εfd + εbi⎞⎠ ⋅ ⎜――⎟ = 0.001102493
⎝ df - c ⎠

⎛ d-c ⎞
εs ≔ ⎛⎝εfe + εbi⎞⎠ ⋅ ⎜――⎟ = 0.0030313
⎝ df - c ⎠

fs ≔ min ⎛⎝fyd , Es ⋅ εs⎞⎠ = 434 MPa

ffe ≔ Ef ⋅ εfe = 449.717 MPa

1.7 ⋅ fck
εc' ≔ ――― = 0.0018
Ecs

4 ⋅ εc' - εc
β ≔ ―――― = 0.71
6 ⋅ εc' - 2 εc

3 ⋅ εc' ⋅ εc - εc 2
α ≔ ――――― = 0.688
3 ⋅ β ⋅ εc' 2

As ⋅ fs + Af ⋅ ffe
c1 ≔ ――――― = 145.716 mm
α ⋅ fck ⋅ β ⋅ bw

εc ≔ if εfe ≤ εfd = 0.0035


‖ε
‖ cu
else
‖ ⎛ c ⎞
‖ ⎛⎝εfe + εbi⎞⎠ ⋅ ⎜――⎟
‖‖ ⎝ df - c ⎠

Modo_Ruptura = “Falha por Esmagamento do Concreto”

thiagoaramac@gmail.com 3
61 99951-9992
REFORÇO DE VIGAS À FLEXÃO
COM LAMINADOS FRP - ACI 440.2R 17
Obra: Endereço
Data: 01/01/2021

CÁLCULO DO MOMENTO RESISTENTE

⎛ β⋅c⎞ ⎛ β⋅c⎞
Mns ≔ As ⋅ fs ⋅ ⎜d - ―― ⎟ = 32.453 tonnef ⋅ m Mnf ≔ ψf ⋅ Af ⋅ ffe ⋅ ⎜df - ―― ⎟ = 5.126 tonnef ⋅ m
⎝ 2 ⎠ ⎝ 2 ⎠

fyd
εsy ≔ ―― = 0.0020667 ØACI ≔ if εs ≥ 0.005 = 0.732
Es ‖ 0.90

else if εs > εsy
‖ 0.25 ⋅ ⎛⎝εs - εsy⎞⎠
‖ 0.65 + ―――――
‖ 0.005 - εsy

else
‖ 0.65

ØMn ≔ ØACI ⋅ ⎛⎝Mns + Mnf⎞⎠ = 27.516 tonnef ⋅ m

CHECAGEM DAS TENSÕES EM ELS


‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾
2 ⎛ ⎛ df ⎞⎞
kELS ≔ ⎛⎝ρs ⋅ ηs + ρf ⋅ ηf⎞⎠ + 2 ⋅ ⎜ρs ⋅ ηs + ρf ⋅ ηf ⋅ ⎜― ⎟⎟ - ⎛⎝ρs ⋅ ηs + ρf ⋅ ηf⎞⎠ = 0.3009
⎝ ⎝ d ⎠⎠

⎛ ⎛ ⎛ kELS ⋅ d ⎞⎞ ⎞
⎜ ⎜MELS + εbi ⋅ Af ⋅ Ef ⋅ ⎜df - ――― ⎟⎟ ⋅ ⎛⎝d - kELS ⋅ d⎞⎠ ⋅ Es ⎟
⎝ ⎝ 3 ⎠⎠
fs_s ≔ min ⎜――――――――――――――――――――――― , 0.8 ⋅ fyd⎟
⎜ ⎛ kELS ⋅ d ⎞ ⎛ kELS ⋅ d ⎞ ⎟
⎜ As ⋅ Es ⋅ ⎜d - ――― ⎟ ⋅ ⎛⎝d - kELS ⋅ d⎞⎠ + Af ⋅ Ef ⋅ ⎜df - ――― ⎟ ⋅ ⎛⎝d - kELS ⋅ d⎞⎠ ⎟
⎝ ⎝ 3 ⎠ ⎝ 3 ⎠ ⎠

fs_s = 295.821 MPa


fs_LIMITE ≔ 0.8 ⋅ fyd = 347.2 MPa Verificação1 ≔ if fs_s ≤ fs_LIMITE = “Ok!”
‖ “Ok!”

⎛ df - kELS ⋅ d ⎞
ff_s ≔ fs_s ⋅ ηfs ⋅ ⎜―――― ⎟ - εbi ⋅ Ef
⎝ d - kELS ⋅ d ⎠
ff_s = 150.197 MPa

ffs_LIMITE ≔ 0.55 ⋅ ffu = 1619.75 MPa Verificação2 ≔ if ff_s ≤ ffs_LIMITE = “Ok!”


‖ “Ok!”

COMPRIMENTO DE ANCORAGEM
‾‾‾‾‾‾‾‾‾‾‾‾‾‾
Ef
nf ⋅ ――⋅ tf ⋅ mm
MPa
ldf_min ≔ ――――――= 36.589 cm
‾‾‾‾‾
fck
――
MPa

Lf ≔ L ⋅ nf = 21 m

thiagoaramac@gmail.com 4
61 99951-9992
REFORÇO DE VIGAS À FLEXÃO
COM LAMINADOS FRP - ACI 440.2R 17
Obra: Endereço
Data: 01/01/2021

RESUMO DO DIMENSIONAMENTO
Especificação da Fibra Utilizada: FRP = Fiber Reinforcement Polymer

Lâmina FRP: Sika® CarboDur® S512 (ou equivalente técnico)

Lf = 21 m Comprimento total das lâminas de FRP

tf = 1.6 mm Espessura da lâmina de FRP

wf = 50 mm Largura da lâmina de FRP

ffuk = 3100 MPa Resistência Última da lâmina de FRP

Ef = 165000 MPa Módulo de Elasticidade da lâmina de FRP

εfuk = 1.70% Deformação Última da lâmina de FRP

nf = 3 Camadas de FRP

Especificação do Adesivo Epóxi:

Resina Epóxi: Sikadur® - 30 (ou equivalente técnico)

Consumo: Largura da Lâmina Consumo de Sikadur® - 30* * espessura


50mm 0.20 a 0.28 kg/m média de 2mm
60mm 0.24 a 0.32 kg/m de adesivo
80mm 0.32 a 0.44 kg/m
90mm 0.40 a 0.56 kg/m
100mm 0.44 a 0.64 kg/m
120mm 0.45 a 0.80 kg/m
150mm 0.68 a 1.00 kg/m
Especificação do Substrato:
- A resistência a aderência para o substrato deve ser de, no mínimo, 1.5MPa.
- Caso não seja possível alcançar esse valor, consultar o calculista.
Possíveis Alternativas:
- Utilizar técnica NSM (Near Surface Mounted) com sulcos abertos próximos à
superfície
- Utilizar tecido SikaWrap® ao invés de lâminas
- O concreto deve ser preparado e limpo até que se obtenha uma superfície livre de pós,
nata de cimento e contaminantes;
- A superfície deve ter textura rugosa e porosidade aberta
Especificação da Proteção:
- Recomenda-se que as fibras sejam protegidas contra ações de vandalismo e contra fogo.
Para tanto, poderá ser executado reboco com tela em sua superfície.
- Durante estocagem das fibras, estas deverão ser acondicionadas em local seco, protegido
de insolação direta e com temperatura máxima de 50°C.

thiagoaramac@gmail.com 5
61 99951-9992

Você também pode gostar