贝菲仪表 INSTALLATION MANUAL

Only trained personnel can perform the instal-


For the convenience of users, we provide the lation, assembly, commissioning and mainte-
Quick Installation Manual along with the prod- nance of the instrument. Maintenance
ucts. For more in-depth product information, involves the opening of the instrument needs
please refer to the Product Operation Manual. to contact the manufacturer, under the guid-
ance of professional personnel.

The user shall install, debug and maintain the


Users need to take good care of the random
product in strict accordance with the product
file of the product, if the fault is reported to
instruction manual and installation manual.
repair, please call the manufacturer or agent.
The manufacturer reserves the right of final
interpretation of the product.

A: Scope of Application

1. BFG-S Electromagnetic Flow Meter


2. BFG070 Electromagnetic Water Meter

B: Installation Instructions

1.Pre-installation inspection

Before the installation of the product, please first check whether there is any mechanical damage caused by incorrect operation
during shipment, whether the communication antenna is damaged, etc. If there is any abnormal condition, please contact the
manufacturer in time.

2.Installation Location The direction of flow

BEIFEI D

≥5D ≥3D

Experience shows that in most cases, the upstream 5 times straight pipe section and the downstream 3 times straight pipe section
can be measured. According to the requirements of the water meter standard document, the upstream straight pipe shall be no
less than 10D and the downstream straight pipe shall be no less than 5D.
In order to better ensure the accurate measuring of the product, it is recommended to install the exhaust valve upstream of the flow
meter and water meter.

BEIFEI
BEIFEI

Products with GPRS remote transmission function should be


Avoid strong vibration installed in areas with good coverage of 2G/3G/4G communica-
tion signals
贝菲仪表 INSTALLATION MANUAL
Medium Temp.
Environment temperature
Lining Mini. Temp. Max. Temp.

Medium Temp. Hard Rubber 0 +65

BEIFEI BEIFEI Neoprene -5 +65

PTFE -40 +180

PFA -40 +180


Avoid exposure to strong sunlight, can choose Choose suitable lining material according to
to add a sunshade medium temperature Environment temperature:-25℃~+70℃

Storage Temp.:-40℃~+70℃

3:Installation Precautions

Take care to protect flanges and lining

BEIFEI
BEIFEI
BEIFEI BEIFEI

√ Correct  Incorrect
Choose suitable material and size of sealing gasket
(1)Lmax

BEIFEI BEIFEI

The direction of flow

(2)Lmin

The label direction is consistent with the flow direction Lmax-Lmin≤0.5mm

BEIFEI

≥10D

BEIFEI N S

Antenna is placed at the entrance of the inspection well to BEIFEI

ensure smooth communication

Stay away from sources of interference as much as possible


贝菲仪表 INSTALLATION MANUAL
1:Back pressure is required at the outlet of water meters and flow meters.
2:If possible, ensure that the length of the straight pipe is sufficient.

The direction of flow

EI BEIFEI

w
IF

flo
BE

of
on
cti
ire
ed
Th
BEIFEI

The direction of flow


√ Correct √ Correct  Incorrect
1:Water meter and electromagnetic flowmeter need to be installed downstream of the 1:Water meters and flow meters shall be installed upstream of the valve.
pump; except for water supply without negative pressure. 2:For the replacement of water meters and electromagnetic flowmeters later, the
2:For the replacement of water meters and electromagnetic flowmeters later, the installation of expansion joints should be considered.
installation of expansion joints should be considered. 3:If possible, ensure that the length of the straight pipe is sufficient.
3:If possible, ensure that the length of the straight pipe is sufficient.
4:Recommended to install a ground rings.
Pump

BEIFEI BEIFEI

Foundation
L≥5D
L≥30D

4:Grounding requirements

Note: The pipe is steel pipe, cast iron pipe and does not contain Note: Pipes are plastic, cement pipes, and steel tubes with
anti-corrosion coating inside. anti-corrosion coating inside.

Instrument grounding post


Grounding Rings
Grounding Rings

BEIFEI BEIFEI

Use more than 4 squared cable separate Use more than 4 squared cable separate
grounding, grounding resistance less than 10 Ω grounding, grounding resistance less than 10 Ω

5: Installation of pressure sensor

Pressure Sensor
Pressure Sensor
Ball Valve

BEIFEI BEIFEI

≤L(Installation length of water meter)

After the installation of the water meter with pressure The pressure sensor should be installed vertically with the horizontal
sensor, open the exhaust valve to drain the air in the plane; After installation, the ball valve is in a normally open state, open the
pipeline exhaust valve, and eliminate the air in the pipeline
贝菲仪表 INSTALLATION MANUAL
C:Common Installation Dimensions of Water Meters

A1 H1
A2

D
BEIFEI d

K
L
DN n×Ø
SIZE Pressure
L(mm) D(mm) K(mm) d(mm) n×Ø A1(mm) A2(mm) H1(mm)
DN(mm) (MPa)
40 1.0 200 145 110 85 4×M16 134 113 150
50 1.0 200 160 125 100 4×M16 134 113 150
65 1.0 200 180 145 120 4×M16 134 113 150
80 1.0 200 195 160 135 4×M16 134 113 150

100 1.0 250 215 180 155 8×M16 134 113 150

125 1.0 250 245 210 185 8×M16 134 113 150

150 1.0 300 280 240 210 8×M20 134 113 150

200 1.0 350 335 295 265 8×M20 134 113 150

250 1.0 400 390 350 320 12×M20 134 113 150

300 1.0 500 440 400 368 12×M20 134 113 150

350 1.0 500 500 460 428 16×M20 134 113 150

400 1.0 600 565 515 482 16×M22 134 113 150

450 1.0 600 615 565 532 20×M22 134 113 150

500 1.0 600 670 620 585 20×M22 134 113 150

电话:021-50393708 ;50393709