Você está na página 1de 14

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

CHICOTES
TESTES
C

Author : FABIANO PAGANUCCI (ROCK) Title : TESTE & DIAGNÓSTICO PREMOPLAM Folio : 1

Date : 02/12/2021 File : 0126-02-12-21 - AGR Folio : 14


1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

POTENCIÔMETRO 5K
B

3VIAS
DT06-3S
M12(MACHO 5 VIAS)
C

VM
D DT04-3P MR
A B

3
PT

2
AZ BR
M12

5
C
LR PT

1
E

POTENCIÔMETRO 5K
F

*DESCONECTE OS SENSORES DO CHICOTE E COLOQUE O CONECTOR DO CHICOTE TESTE*


→ SENSOR DE PRESSÃO DEFENSIVO (LIQUÍDO 1/2) A PRESSÃO NA TELA VAI DE 0-300PSI,COM O CHICOTE TESTE
G
CONECTADO GIRE O POTENCIÔMETRO PARA SIMULAR UMA PRESSÃO 0-300 PSI.
→ COM O VALOR NA TELA,SEU PROBLEMA É SENSOR, CASO NÃO APARECE NENHUM VALOR SEU PROBLEMA É CHICOTE.
→ NO CASO DE CHICOTE PODE ALIMENTAÇÃO DO SENSOR (12V) OU SINAL QUE NÃO CHEGA A ECU..
→ SENSOR DE NIVEL (MUDA) O VALOR NA TELA VAI DE 0-100% ,COM O CHICOTE TESTE CONECTADO GIRE O POTENCIÔMETRO PARA
SIMULAR UM VALOR DE NIVEL .
H → COM VALOR NA TELA,SEU PROBLEMA É SENSOR,CASO NÃO APARECE NEMHUM VALOR SEU PROBLEMA É CHICOTE.
→ NO CASO DE CHICOTE PODE SER ALIMENTAÇÃO (12V) OU SINAL QUE NÃO CHEGA A ECU.
→ ***LEMBRANDO QUE SENSOR MUDA DESCONECTADO APARECE 100% NA TELA***
Author : FABIANO PAGANUCCI (ROCK) Title : CHICOTE SIMULADOR DE PRESSÃO DEFENSIVO & NIVEL Folio : 2

Date : 03/12/2021 File : 0126-25-02-20 - AGM Folio : 14


1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

POTENCIÔMETRO 5K
B

3VIAS
M12(MACHO 5 VIAS)
DT06-3S
C

VM
D DT04-3P MR
A B

3
PT

2
AZ BR

5
C
LR PT

1
E

M12

POTENCIÔMETRO 5K
F

*DESCONECTE OS SENSORES DO CHICOTE E COLOQUE O CONECTOR DO CHICOTE TESTE*


→ SENSOR DE ADUBO (SOLÍDO 1/2) NA TELA VAI APARECER O STATUS (VERDE),COM O CHICOTE TESTE
G
CONECTADO GIRE O POTENCIÔMETRO PARA SIMULAR O STATUS VERDE.
→ COM O STATUS NA TELA,SEU PROBLEMA É SENSOR, CASO NÃO APARECE NENHUM VALOR SEU PROBLEMA É CHICOTE.
→ NO CASO DE CHICOTE PODE ALIMENTAÇÃO DO SENSOR (12V) OU SINAL QUE NÃO CHEGA A ECU..
→ SENSOR DE MUDA (MUDA) NA TELA VAI APARECER O STATUS (VERDE),COM O CHICOTE TESTE
CONECTADO GIRE O POTENCIÔMETRO PARA SIMULAR O STATUS VERDE .
H → COM VALOR NA TELA,SEU PROBLEMA É SENSOR,CASO NÃO APARECE NEMHUM VALOR SEU PROBLEMA É CHICOTE.
→ NO CASO DE CHICOTE PODE SER ALIMENTAÇÃO (12V) OU SINAL QUE NÃO CHEGA A ECU.

Author : FABIANO PAGANUCCI (ROCK) Title : CHICOTE SIMULADOR SENSOR MUDA & ADUBO Folio : 3

Date : 03/12/2021 File : 0126-25-02-20 - AGM Folio : 14


1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

POTENCIÔMETRO
B 5K

3VIAS
M12(MACHO 5 VIAS) DT06-3S
C

VM
D DT04-3P MR
A B

3
PT

2
AZ BR
M12

5
C
LR PT

1
E

POTENCIÔMETRO 5K
F

*DESCONECTE OS SENSORES DO CHICOTE E COLOQUE O CONECTOR DO CHICOTE TESTE*


→ SENSOR DE PRESSÃO BLOCO PRESSÃO NA TELA VAI DE 0 - 400 BAR,COM O CHICOTE TESTE
CONECTADO GIRE O POTENCIÔMETRO PARA SIMULAR UMA PRESSÃO 0 - 400 BAR .
G → COM O VALOR NA TELA,SEU PROBLEMA É SENSOR, CASO NÃO APARECE NENHUM VALOR SEU PROBLEMA É CHICOTE.
→ NO CASO DE CHICOTE PODE ALIMENTAÇÃO DO SENSOR (5/12V) OU SINAL QUE NÃO CHEGA A ECU..

*** LEMBRANDO QUE O SENSOR BOSCH SUA ALIMENTAÇÃO É 5V,SINAL 0,5-4,5V, SENSOR HYDAC ALIMENTAÇÃO 12V,SINAL 0-10V***

Author : FABIANO PAGANUCCI (ROCK) Title : CHICOTE SIMULADOR DE PRESSÃO BLOCO HIDRAULICO Folio : 4

Date : 03/12/2021 File : 0126-25-02-20 - AGM Folio : 14


1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

B 3 VIAS
SENSORES

2 VIAS
PLUG BANANA VALVÚLAS
C
CÂMERAS 2 VIAS
BOMBAS ELET
M12
SENSORES 4 VIAS
ENCODES
D

*DESCONECTE OS SENSORES DO CHICOTE E COLOQUE O CONECTOR DO CHICOTE TESTE*


G → COM ESTE CHICOTE ANALISAMOS AS ALIMENTAÇÕES DO SISTEMA.
→ COM O USO DE UM MULTÍMETRO COMUN NA FUNÇÃO DE TENSÃO CONTINUA, VERIFICA A ALIMENTAÇÃO SEM
PRECISAR SABER QUAL É O PINO CERTO DA ALIMENTAÇÃO.
→ A TENSÃO IDEAL É 12 A 14V PARA TODOS OS SENSORES,UNICO COM 5 V É SENSOR BOSCH(BLOCO)

Author : FABIANO PAGANUCCI (ROCK) Title : CHICOTE TESTE ALIMENTAÇÃO DO SISTEMA Folio : 5

Date : 03/12/2021 File : 0126-12-07-21 - AGM Folio : 14


1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

MR
A

AZ

2
B
M12

1
C DT04-3P
PLUG BANANA
A B

PLUG BANANA C

DT04-4P
1 4

2 3

DT04-2P
1 2

DTP04-2P
1 2

G
VM 4 1

CÂMERA 3 2

PT
H

Author : FABIANO PAGANUCCI (ROCK) Title : CHICOTE DE TESTE ALIMENTAÇÃO (ESQUEMA ELETRICO) Folio : 6

Date : 03/12/2021 File : 126-25-02-20 - AGM Folio : 14


1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

3VIAS
DT04-3P
B

D A B

DT06-3S C 1K
10K

RESISTORES DE 1K & 10K DE 1/4W

F *DESCONECTE OS SENSORES DO CHICOTE E COLOQUE O CONECTOR TESTE*


→ ESTE CONECTOR SIMULA UMA PRESSÃO FIXA, CONECTADO AO CHICOTE SEUS VALORES SÃO;
→ PRESSÃO LIQUIDO(DEFENSIVOS) →79 PSI (1,1V-ECU BOSCH)
→ PRESSÃO BLOCO → 0,4V (ECU BOSCH)
→ PRESSÃO LIQUIDO(DEFENSIVOS) →56 PSI /89 PSI (ECU HYDAC)
G
→ PRESSÃO BLOCO → 41BAR /80 BAR (ECU HYDAC)
→ PRESSÃO MOTOBOMBA 6 BAR /10 BAR
→ PRESSÃO CARRETEL 3,6 BAR
→ ESTES VALORES SÃO APENAS APROXIMADOS
→ COM O VALOR NA TELA,SEU PROBLEMA É SENSOR, CASO NÃO APARECE NENHUM VALOR SEU PROBLEMA É CHICOTE.
H → NO CASO DE CHICOTE PODE ALIMENTAÇÃO DO SENSOR (5/12V) OU SINAL QUE NÃO CHEGA A ECU..

Author : FABIANO PAGANUCCI (ROCK) Title : CONECTOR SIMULADOR DE SINAL PRESSÃO FIXO Folio : 7

Date : 06/12/2021 File : 0126-24-10-20 - AGM Folio : 14


1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

PLUG BANANA
2VIAS 2VIAS
DT06-2S DT04-2P
C

D
*DESCONECTE O CHICOTE DA VÁLVULA E COLOQUE O CONECTOR DO CHICOTE TESTE EM SÉRIE *
→ CHICOTE MONITORAMENTO DE CORRENTE (AMP) COM ESTE CHICOTE MONITORAMOS A CORRENTE DE ACIONAMENTO DAS VÁLVULAS
PWM E ON/OFF, ETC.
→ COM O MULTÍMETRO COMUN COM FUNÇÃO "A" E COM ESTE CHICOTE TEMOS OS VALORES DA CORRENTE.
E → OS VALORES DE CORRENTE PWM SÃO DE 0.6 -1.6 AMP HYDAC / 0.4 -1.8 AMP BOSCH
→ LEMBRANDO QUE OS VALORES DE CORRENTE NO DISPLAY DO MULTÍMETRO VARIA DE ACORDO CADA APLICAÇÃO

Author : FABIANO PAGANUCCI (ROCK) Title : CHICOTE MONITORAMENTO DE CORRENTE (AMP) Folio : 8

Date : 06/12/2021 File : 0065-24-10-16 - AGR Folio : 14


1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

DT04-2P DT06-2S
E 1 2
2 1

↑ LIGAR NO CONECTOR ↑ LIGAR NO CONECTOR


PLUG BANANA DO CHICOTE (SAÍDAS PWM/ON-OFF) DA VÁLVULA
F

← ← LIGAR AO MULTÍMETRO
NA FUNÇÃO "A" OU 10A
G
PLUG BANANA

Author : FABIANO PAGANUCCI(ROCK) Title : CHICOTE MONITORAMENTO DE CORRENTE (ESQUEMA ELETRICO) Folio : 9

Date : 07/12/2021 File : 0065-24-10-16- AGR Folio : 14


1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

A
DTP04-2P
2VIAS

2VIAS
DT06-2S
BOTÃO DE PULSO
C 2VIAS
DTP06-2S

*DESCONECTE O CHICOTE DA VÁLVULA E COLOQUE O CONECTOR DO CHICOTE TESTE*

E → ESTE CHICOTE FAZ ACIONAMENTO MANUAL DIRETO NA VÁLVULA SEM INTERVENÇÃO AO SISTEMA ECU
→ O ACIONAMENTO PODE SER NO BLOCO ON/OFF OU PWM
→ LEMBRANDO QUE NA PWM LIGA DIRETO A 100% DO SEU CONTROLE
→ NA LIGAÇÃO DO BLOCO LIGAR SEMPRE A VÁLVULA DA VENTAGEM (44) JUNTO PARA LIBERAR A PRESSÃO DO SISTEMA
→ ESTE CHICOTE É IDEAL MANUTENÇÃO E TESTE HIDRAULICOS
F DT06-2S → CONFERE SE AS VÁLVULAS ESTÃO FUNCIONANDO NORMALMENTE
2 1

1 2

G
DT04-2P

DT06-2S DTP06-2S
2 1 2 1

H
BOTÃO DE PULSO

Author : FABIANO PAGANUCCI (ROCK) Title : CHICOTE ACIONAMENTO MANUAL DAS VÁLVULAS Folio : 10

Date : 09/12/2021 File : 0065-24-10-16- AGR Folio : 14


1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

FUSIVEL 15A

C DTP06-2S
GARAR (JACARE) 2 1

Author : FABIANO PAGANUCCI Title : CHICOTE ALIMENTAÇÃO DO TESTE DE VÁLVULAS (JACARE) Folio : 11

Date : 09/12/2021 File : 0065-24-10-16 - AGR Folio : 14


1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

3VIAS
DT06-3S

C
3VIAS
3VIAS
DT04-3P
DT04-3P

*DESCONECTE O ENCODER DO CHICOTE E COLOQUE O CONECTOR DO CHICOTE TESTE*


D
→ CHICOTE TESTE SINAL ENCODER ESTE CHICOTE TEM COMO OBJETIVO JUMPEAR UM SINAL DE ENCODER PARA OUTRA
ENTRADA DE ENCODER ONDE CASO NÃO TENHA OUTRO SENSOR PARA SUBSTITUIR .
→ EXEMPLO DE MANUTENÇÃO NA MAQUINA ESTAMOS COM PROBLEMA NO ENCODER MUDA, COM ESTE CHICOTE VOCÊ
DESCONECTA O ENCODER (SOLÍDO) QUE ESTA FUNCIONANDO DO CHICOTE E COLOCA O CHICOTE JUMPEANDO O SINAL
E → NA OUTRA PONTA DO CHICOTE TESTE CONECTA AO CHICOTE QUE ESTA COM PROBLEMA .
→ LIGANDO O SOLÍDO NA FUNÇÃO MANUAL, ABRA A TELA DE DIAGNOSTICO E CONFERE SE O ENCODER MUDA ESTA
FUNCIONANDO.
→ NÃO APARECE NENHUM VALOR NA TELA SEU PROBLEMA É CHICOTE.
→ TEM SINAL NA ENTRADA, SEU PROBELMA É SENSOR
F

Author : FABIANO PAGANUCCI (ROCK) Title : CHICOTE TESTE SINAL ENCODER Folio : 12

Date : 10/12/2021 File : 0065-24-10-16- AGR Folio : 14


1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

B *EXEMPLO DA LIGAÇÃO DO CHICOTE TESTE*

ENTRADA
C
ENCODER
SOLIDO

ENTRADA
E ENCODER
MUDA
DT04-3P DT04-3P

A B A B

F
C C

G
DT06-3S
_

B A

H C

Author : FABIANO PAGANUCCI(ROCK) Title : CHICOTE TESTE SINAL ENCODER (ESQUEMA ELETRICO) Folio : 13

Date : 10/12/2021 File : 0065-24-10-16 - AGR Folio : 14


1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

Author : FABIANO PAGANUCCI (ROCK) Title : AGRADECIMENTOS Folio : 14

Date : 10/12/2021 File : 0065-24-10-16 - AGR Folio : 14

Você também pode gostar