Você está na página 1de 22

TELEMAR

Solues para voc

Alcatel 1660SM
STM-64 Multiservice Metro Node

1660SM Rel. 5.0

STM-64 Multiservice Metro Node - 1660SM Rel. 5.0

OBJETIVO: Descrever as principais funcionalidades e estrutura do OMSN's 1660SM Rel.

CWDM
SIGNAL

1- Descrio do Sistema:
?
Alcatel Optmex Multi Service Node (OMNS) compatvel tanto com sistemas PDH's
quanto para SDH's.
?
OMNS pode ser configurado como mltiplo terminal de linha, mltiplo add-drop ou
como cross-connect.
?
OMNS tem ATM integrado, equipado com Ethernet, Fast Ethernet, Gigabit Ethernet
e Ethernet Switch's (ISA).

2 Mbit/s

STM-1

34 / 45 Mbit/s

OMSN

140 Mbit/s

STM-4

ATM
STM-16
Ethernet

OC-3

FDDI

ESCON

DIG. VIDEO

FIBER CHANNEL

STM-64

FICON

MPLS

TIPO DE PROTEES:
?
Equipament Protection
EPS
?
Network Protection
MSP
SNCP/N e SNCP/I
2F MS-SPRING
4F MS-SPRING
D&C

TELEMAR

Solues para voc

CGR - CENTRO DE GERNCIA DE REDE - SUPORTE NVEL II TX


TTULO

NE 1660SM - ALCATEL

DATA

12/07/2006

ELABORADO
POR

ANDR GESTEIRA

2- Diferenas entre equipamentos ADMs e equipamentos OMSN:

ADM
MATRIX

AGGR.

TRIB.

TRIB.

AGGR.

TRIB.

PORT

PORT

PORT

MATRIX
OMSN
PORT

PORT

OBS.: 1) Nos equipamentos ADM temos que especificar as portas que sero
agregadas e as tributrias;
2) Nos OMSN no este tipo de diferenciao, dando assim maior flexibilidade
na criao de cross-conexes;
3) Compatibilidade total entre equipamentos ADM e OMSN;

TELEMAR

Solues para voc

CGR - CENTRO DE GERNCIA DE REDE - SUPORTE NVEL II TX


TTULO

NE 1660SM - ALCATEL

DATA

12/07/2006

ELABORADO
POR

ANDR GESTEIRA

3- Funcionamento interno das do SHELF:

TELEMAR

Solues para voc

CGR - CENTRO DE GERNCIA DE REDE - SUPORTE NVEL II TX


TTULO

NE 1660SM - ALCATEL

DATA

12/07/2006

ELABORADO
POR

ANDR GESTEIRA

4- Comunicao interna (detalhada):


PORT
ASICS

EC

SC

PORT

MIB

ASICS

PORT
ASICS

ASICS = No h mais falhas de verso


(Application Specific Integrated Circuit)

ISA

MIB

OBS.: se for colocado uma placa nova esta placa se


comunica com a SC, na qual a mesma interroga a MIB do
equipamento na EC, para que a mesma atualize a verso
de acordo com a que esta sendo usada.

4- Barramentos:

As entradas de RA, QMD, QB,


HK / RE das placas CONGIs no
so protegidas.

BARRAMENTO
DE GERNCIA

TELEMAR

Solues para voc

CGR - CENTRO DE GERNCIA DE REDE - SUPORTE NVEL II TX


TTULO

NE 1660SM - ALCATEL

DATA

12/07/2006

ELABORADO
POR

ANDR GESTEIRA

REA DE PORTAS

AREA DE ACESSO

5- Sistema Mecnico do Shelf:

REA DE ACESSO

REA DE PORTAS

Slot 1-9, 13-21: placas de acesso


Slot 10: CONGI A

Slot 22: EQUICO (PQ2 / EC)


Slot 23, 40: Matrix N (Matrix E)

Slot 11: SERVICE


Slot 24-39: High Speed / Low
Speed port

Slot 12: CONGI B

TELEMAR

Solues para voc

CGR - CENTRO DE GERNCIA DE REDE - SUPORTE NVEL II TX


TTULO

NE 1660SM - ALCATEL

DATA

12/07/2006

ELABORADO
POR

ANDR GESTEIRA

1 2 3 4 5 6 7 8 9 10 11 12 13 13 14 15 16 17 18 19 20

TAMPA CEGA

MATRIXB
TBUS

ENHANCED

ENHANCED

ENHANCED

ENHANCED

ENHANCED

ENHANCED

ENHANCED

ENHANCED

TBUS

EQUICO

MATRIXA

22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41

Slot onde sempre estar


a proteo de 2MB.

STM-16 ou
STM-64
PLACAS COMUNS (Common Cards)
LS CARD
HS Cards
ISA CWDM CARD
AMPLIFIER

TELEMAR

Solues para voc

CGR - CENTRO DE GERNCIA DE REDE - SUPORTE NVEL II TX


TTULO

NE 1660SM - ALCATEL

DATA

12/07/2006

ELABORADO
POR

ANDR GESTEIRA

HS e ISA CARDS

2MB CARDS

ISA PR CARDS

PORT
CARD SLOT

ACCESS CARD
SLOT

PORT
CARD SLOT

ACCESS
CARD SLOT

24

1, 2, 3

24

PORT
CARD
SLOT

27

4, 5, 6

25

25-26

2-3

3-4

4-5

30

7, 8, 9

26

26-27

3-4

4-5

5-6

32
SPARE

REQUERIDA
ACCESS CARD

27

27-28

4-5

5-6

6-7

33

13, 14, 15

28

28-29

5-6

6-7

7-8

36

16, 17, 18

29

29-30

6-7

7-8

8-9

39

19, 20, 21

30

30-31

7-8

8-9

31

31-32

8-9

32

13

33

14

32-33

34

15

35

LEFT
MIDDLE RIGHT
CARD
CARD
CARD
ACCESS ACCESS ACCESS
SLOT
SLOT
SLOT

13-14 14-15

33-34

13-14 14-15 15-16

16

34-35

14-15 15-16 16-17

36

17

35-36

15-16 16-17 17-18

37

18

36-37

16-17 17-18 18-19

38

19

37-38

17-18 18-19 19-20

39

20

38-39 18-19 19-20 20-21

OBS.: Para determinada placa inserida na rea de portas, ela precisar de uma
determinada placa na rea de acesso;
A placa de proteo para tributrios de 2MB devem ser colocadas no slot
32;
Placas STM-4, STM-16, STM-64, ATM, GIGABIT Ethernet, PR-EA, 4xANY,
ES1-8FE, ES1-8FX e ES4-8FE no possuem placas de acesso;
6- Sincronismo:

SELETOR A

Squelch
A

Port Card
SDH / PDH

Service Card
T4 / T5

SELETOR C

Squelch
B

T1 / T2
T3 / T6

SELETOR B

SETG

SERVICE
Card

T0
Todas as Unidades
OSC

SETS

PLACA MATRIX

TELEMAR

Solues para voc

CGR - CENTRO DE GERNCIA DE REDE - SUPORTE NVEL II TX


TTULO

NE 1660SM - ALCATEL

DATA

12/07/2006

ELABORADO
POR

ANDR GESTEIRA

7- Descrio do Hardware:
7.1- PLACAS LS e HS:

TELEMAR

Solues para voc

CGR - CENTRO DE GERNCIA DE REDE - SUPORTE NVEL II TX


TTULO

NE 1660SM - ALCATEL

DATA

12/07/2006

ELABORADO
POR

ANDR GESTEIRA

TELEMAR

Solues para voc

CGR - CENTRO DE GERNCIA DE REDE - SUPORTE NVEL II TX


TTULO

NE 1660SM - ALCATEL

DATA

12/07/2006

ELABORADO
POR

ANDR GESTEIRA

ACRONYM
P4S1N

SLOTS
24 A 29

Mdulos STM-1: Eletrico-SC / PC-FC /PC


ICMI, IS-1.1, IL-1.1, IL-1.2, MM1
ACRONYM
P4E4N

SLOTS
24 A 29

Mdulos STM-1: Eletrico-SC / PC-FC /PC


ICMI, IS-1.1, IL-1.1, IL-1.2, MM1
ACRONYM
A2S1

SLOTS
24 A 29

Mdulos STM-1: Eletrico-SC / PC-FC /PC


ICMI, IS-1.1, IL-1.1, IL-1.2, MM1
MDULOS - ESPECIFICAO
?
ICMI - Interface - Cdigo - Marca - Inverso (140Mb PDH
/ 155Mb SDH)
?
IS1.1 - Interface Short Haul STM-1 (155Mb) - = 1310nm
(aproximandamente 15 Km)
?
IL1.1 - Interface Long Haul STM-1 (155Mb) - = 1310nm
(aproximandamente 40 Km)
?
IL1.2 - Interface Long Haul STM-1 (155Mb) - = 1550nm
(aproximandamente 80 Km)
?
MM.1 - Mult Modo STM-1 (155Mb) - Curta distncia
(aproximandamente 2 Km)
LEGENDA
P4S1N
(1) STM-1 - Canal 1
(2) STM-1 - Canal 2
(3) LED BICOLOR:

Vermelho: Falha na unidade


Verde: Unidade em Servio

P4E4N
(1) 140 / STM-1 / OC-3 - Canal 1
(2) 140 / STM-1 / OC-3 - Canal 2
(3) LED BICOLOR:
Vermelho: Falha na unidade
Verde: Unidade em Servio
A2S1
(1) 140 / STM-1 / OC-3 - Canal 3
(2) 140 / STM-1 / OC-3 - Canal 4
(3) LED BICOLOR:
Vermelho: Falha na unidade
Verde: Unidade em Servio
MDULOS

Eltrico
140Mb e STM-1

TELEMAR

Solues para voc

ptico
STM-1 e STM-4

ptico
STM-1 e STM-4

CGR - CENTRO DE GERNCIA DE REDE - SUPORTE NVEL II TX


TTULO

NE 1660SM - ALCATEL

DATA

12/07/2006

ELABORADO
POR

ANDR GESTEIRA

ACRONYM
P4S4N

SLOTS
25, 26, 28, 29, 34, 35, 37 e 38

LEGENDA
(1) STM-4 - Canal 1
(2) STM-4 - Canal 2
(3) LED BICOLOR:
Vermelho: Falha na unidade
Verde: Unidade em Servio
MDULOS
IS-4.1, IL-4.1, IL -4.2

ACRONYM
A2S4

SLOTS
4 A 19

LEGENDA
(1) STM-4 - Canal 3
(2) STM-4 - Canal 4
(3) LED BICOLOR:
Vermelho: Falha na unidade
Verde: Unidade em Servio
MDULOS
IS-4.1, IL-4.1, IL -4.2
(uso futuro)

CONECTORES
FC/PC
SC/PC
SFF

TELEMAR

Solues para voc

CGR - CENTRO DE GERNCIA DE REDE - SUPORTE NVEL II TX


TTULO

NE 1660SM - ALCATEL

DATA

12/07/2006

ELABORADO
POR

ANDR GESTEIRA

STM-N

INTERFACES
AMPLIFICADORES
WAVELENGHT
PTICOS
PTICAS

BST15

STM-1

L-1.2 JE1

1530 , 1560

STM-4

L-4.2 JE

1530 , 1560 BST10, 15, 17

L-16.2 JE2

1550 , 1560 BST10, 15, 17

L-16.2 JE3

1550 , 1560 BST10, 15, 17

STM-16

STM-64

L-64.2

1530 , 1565

BST10

BOOSTER
MODULE

IN
VINDO
DA PORTA
STM

WDM
coupler

OUT
PARA LINHA

BOOSTER

TELEMAR

Solues para voc

CGR - CENTRO DE GERNCIA DE REDE - SUPORTE NVEL II TX


TTULO

NE 1660SM - ALCATEL

DATA

12/07/2006

ELABORADO
POR

ANDR GESTEIRA

7.2- PLACAS COMUNS:

TELEMAR

Solues para voc

CGR - CENTRO DE GERNCIA DE REDE - SUPORTE NVEL II TX


TTULO

NE 1660SM - ALCATEL

DATA

12/07/2006

ELABORADO
POR

ANDR GESTEIRA

7.3- PLACAS ISA:

7.4- FAN SHELF:

TELEMAR

Solues para voc

CGR - CENTRO DE GERNCIA DE REDE - SUPORTE NVEL II TX


TTULO

NE 1660SM - ALCATEL

DATA

12/07/2006

ELABORADO
POR

ANDR GESTEIRA

7.5- T-BUS:
ACRONYM
TBUS

SLOTS
42 , 43

(1) LED BICOLOR:


Vermelho: Falha na unidade
Verde: Unidade em Servio

PLACA ATRS DA
PLACA MATRIX

8- APNDICE - Lista de PLACAS:

1660SM
TIPO DE PLACA

ACRONYM

63 X 2Mb PORT

P63E1
P63E1N
P63E1N-M4

24, 27, 30, 32, 33,


36, 39

21 x 2Mb
ACESS

A21E1

18

1 a 9 e 13 a 21

3 x 34 / 45 Mb
PORT

P3E3T3

16

24 a 39

3 x 34 / 45 Mb
ACCESS

A3E3

16

2 a 9 e 13 a 20

HIGH SPEED PROCTECTION


ACCESS

HPROT

2 a 9 e 13 a 20

4x 140 / STM-1
ACCESS

P4E4N

16

24 a 39

2x 140 / STM-1
ACCESS

A2S1

16

2 a 9 e 13 a 20

TELEMAR

Solues para voc

MAX
QTD

SLOTS

CGR - CENTRO DE GERNCIA DE REDE - SUPORTE NVEL II TX


TTULO

NE 1660SM - ALCATEL

DATA

12/07/2006

ELABORADO
POR

ANDR GESTEIRA

BOARD TYPE

1660SM
ACRONYN MAX
SLOTS
QTD

BOARD TYPE

4 x eletrical STM-1 Port

P4ES1

16

4 x elet. STM-1 Port acess

A4ES1

16

4 x STM-1 Port

P4S1N

16

24 a 39

2 x 140 / STM-1 Port acess

A2S1

16

2 a 9, 13 a 20

4 x OC3 AU3 / TU3 port

P4OC3

16

24 a 39

1 STM-4 Port

S-4.1, L-4.1, L4.2

16

24 a 39

25, 26, 28, 29


34, 35, 37, 38

1660SM
ACRONYN MAX
SLOTS
QTD

BOOSTER

BST10 - BST15
BST17

2 a 8, 13 a 19

STM-16 - PREAMPLIFIER

PR16

2 a 8, 13 a 19

24 a 39

1660SM
ACRONYN MAX
SLOTS
QTD
TBUS

23, 40

EQUICO

(*) 1

22

24 a 39

PQ2 / EQC

(**) 1

22

(**) 8

2 a 8, 13 a 20

MATRIXN

(*) 2

23, 40

A16ES1E

(**) 16

2 a 9, 13 a 20

MATRIXE

(**) 2

23, 40

S-16.1 ND
L-16.1 ND
L16.2 ND

CONGI

10, 12

25, 26, 34, 37


SERVICE

11

I-16.1 ND

25, 26, 34, 37

STM-16 Host Port

CO-16

25, 26, 34, 37

STM-16 Slim Host Port

O-16ES

(**) 16

24 a 39

4 x Any Host Card

4 x ANYC

25, 26, 34, 37

STM-64 Port

S-64.2E
I-64.1E

(**) 4

25, 26, 34, 37

4 x STM-4 Port

P4S4N

2 x STM-4 acess

A2S4

16 x STM-1 / 4 x STM-4 Port

P16S1-4E

(**) 16

12 x Optical STM-1 acess

A12OS1E

16 x Elet. STM-1 acess

STM-16 Port

BOARD TYPE

TELEMAR

Solues para voc

(*) 1660 Rel. 4.4


(**) 1660 Rel. 5.2

1660SM
ACRONYN MAX
SLOTS
QTD

ATM Matrix 4x4

ATM4X4 - ATM4X4V2
ATM4X4D3

24 a 39

ATM Matrix 8x8

ATM8x8

24 a 38

Ethernet Port

ETH-MB

12

24 a 39

Ethernet Access

ETH-ATX

12

2 a 9, 13 a 20

Gigabit Ethernet Access

GETH-AG

2 a 9, 13 a 20

PR_EA Board

PREA4ETH
PREA1GBE

24 a 39

PR Port

ISA-PR

24 a 38

PR Gigabit Ethernet Access

2GBA-PR

2 a 8, 13 a 20

PR Fast Ethernet Access

16FEA-PR

2 a 8, 13 a 20

CGR - CENTRO DE GERNCIA DE REDE - SUPORTE NVEL II TX


TTULO

NE 1660SM - ALCATEL

DATA

ELABORADO
POR

ANDR GESTEIRA

9- PROCEDIMENTOS DE MANUTENO:
9-1- Troca de PLACA EQUICO, SYNTH1N, PQ2/EQC, SYNTH16:
Para iniciar a Configurao Bsica do equipamento necessrio limpar a base de dados
da Equipment Controller (EC) seguindo o Procedimento abaixo:
I- Extrair a placa EC;
II- Mover as MICRO-SWITCH conforme mostra a figura 2;
III- Inserir a placa EC e esperar os LEDs das placas acenderem;
IV- Verificar se a base de dados esta LIMPA: todos os slots aparecerem fazios,
exeto as placas principais: EC, MATRIX, CONGI e T-BUS;
V- Extrair a placa EC e colocar os MICRO-SWITCH nas posies originais: cuidado
pois alguns alarmes podem aparecer ao ser inserida a placa no sub.
EQUICO, SYNTH1N

Condio de
operao
Normal

ON

PQ2/EQC, SYNTH16

1 23 4

OFF

Movendo a SWITCH 2
de OFF para ON
feito o CLEAN da DB

ON

1 2

ON

Figura 1

OFF

1 23 4

1 2

ON

Figura 2
OFF

OFF

PROCEDIMENTO
NOVA UNIDADE: switch#1=OFF e switch#2=ON (reset database)
inserir a nova unidade
CONDIO
SW e release mesma do NE

CONDIO
Unidade com SW diferente

CONDIO
Unidade sem SW

CONDIO
Unidade com SW errado

Retirar a placa, colocar a switch#1=ON e


switch#2=ON e inserir a placa novamente
Baixar o SW do NE e executar o
procedimento de DOWNLOAD Normal

Baixar o SW do NE e executar o
procedimento do SIBDL

REMOVER a placa colocar a switch#1=ON e a switch#2=OFF


(Posio de reset da base de dados e downloda do BACKUP)
Inserir a placa novamente
CONDIO
MIB GRAVADA no CRAFT TERMINAL
A gerncia envia a MIB salva com
as configuraes corretas do NE

O CT envia a MIB contendo as


configuraes corretas do equipamento

ATIVADO pela gerncia a MIB envida

ATIVADO pela CT a MIB enviada

REMOVER a placa colocar a switch#1=OFF e a switch#2=OFF


(Posio de operao normal)
Inserir a placa novamente

TELEMAR

Solues para voc

CGR - CENTRO DE GERNCIA DE REDE - SUPORTE NVEL II TX


TTULO

NE 1660SM - ALCATEL

DATA

12/07/2006

ELABORADO
POR

ANDR GESTEIRA

Consideraes importantes:
EQUICO, SYNTH1N

+ OU 2 min

PQ2/EQC, SYNTH16

OPERACIONAL

NORMAL = DEFAUL

OFF

OFF

OFF

OFF

OFF

OFF

RESET MIB

OFF

ON

OFF

OFF

OFF

ON

ON

OFF

OFF

OFF

ON

OFF

ON

ON

ON

ON

+ OU - RESET MIB + COPIA DA


2 min LOCAL CONFIGURATION
EXECUTAR O SIBDL
FORMATAR A FLASH CARD
+ DOWNLOAD DO PACOTE

NO OPERACIONAL

TROCA DA EQUICO SEM TROCA DA FLASH CARD:


> No necessrio seguir o passo-a-passo, somente colocar a FLASH CARD antiga na
placa nova.
9-2- ALARME de INSIDE FAILURE:
Ir em Diagnose > Internal Link Monitor:
MATRIXN - r01sr1/board#23 MATRIXN - r01sr1/board#40

P4ES1N - r01sr1/board#24

P4ES1N - r01sr1/board#25

P4ES1N - r01sr1/board#26

MATRIX

GETH-MB - r01sr1/board#28

ACTIVA
P16S14E - r01sr1/board#30

P16S1-4E - r01sr1/board#31

S-642E - r01sr1/board#34

S-642E - r01sr1/board#37

EXEMPLOS:
CASO1:
MATRIXN do slot 23 na principal com um dos links (setas em VERDE) em vermelho, ser
necessrio resetar a placa relativa a seta;
CASO2:
MATRIXN do slot 40 na reserva porem todos os links da mesma esta em vermelho, ser
necessrio resetar a placa MATRIXN do slot 40.
OBS.: Este alarme no causa perda de trfego, mas em caso de comutaes
de placas que esteja alarmadas pode gerar perdas.

TELEMAR

Solues para voc

CGR - CENTRO DE GERNCIA DE REDE - SUPORTE NVEL II TX


TTULO

NE 1660SM - ALCATEL

DATA

12/07/2006

ELABORADO
POR

ANDR GESTEIRA

9-3- ALARME de CPE:

LOS

URU

LOF

URU

SPI
TD

TIM

DS

RST

TF

CSF

PM-AS

RDI

EBER AIS

MST
CSF

CPE

MSP
PM-AS

Este alarme significa Erro de Comunicao do Protocolo de COMUTAO, que pode


ser resolvido com comutao da placa MATRIXN tanto da estao em que o alarme esta
presente quanto na distante. Se ao comutar a MATRIX do equipamento onde o alrme
esta presente no sair o alarme, teremos que comutar o da ponta distante.
Existem casos onde necessrio at resetar a placa em campo.
OBS.: Este alarme no causa perda de trfego, mas em caso de comutao em
RING pode gerar perdas de AU-4.

9-3- Forar o LASER:

LOS

URU LOF

URU

SPI
TD

TIM

DS

RST

TF

CSF

PM-AS

RDI EBER AIS

MST
CSF

CPE

MSP
PM-AS

Entrar na placa marcar a parte fsica da placa e ir em Port > Phyisical Media
> Als Manegement, dentro da caixa se ser aberto, colocar em Als Function:

FORAR O LASER

DESLIGAR O LASER

REESTABELECER O LASER

Forced ON

Forced OFF

Als Enable

OBS.: Foi verificado que em alguns casos de rompimento de fibra, houveram situaes
onde para reestabelecer o laser, tivemos que antes de tudo forar o mesmo, dependendo
da verso do software do equipamento.

TELEMAR

Solues para voc

CGR - CENTRO DE GERNCIA DE REDE - SUPORTE NVEL II TX


TTULO

NE 1660SM - ALCATEL

DATA

12/07/2006

ELABORADO
POR

ANDR GESTEIRA

9-4- Comutaes MSP-RING:


LOS

URU

LOF

URU

SPI
TD

TF

TIM

DS

RST
CSF

PM-AS

RDI

EBER

AIS

MST
CSF

CPE

MSP
PM-AS

Marcar o Bloco referente a comutao, MSP, ir em Port > MSP > MSP
Commands, e na tela que se abrir executar o comando desejado.
OBS. IMPORTANTE:
PROTECTED - Placa que esta no esquema de proteo como principal, ou seja,
PROTEGIDA;
PROTECTING - Placa que esta no esquema de proteo como reserva, ou seja,
PROTEGENDO.
Comandos MANUAIS:
Este comando quando h algum tipo de falha na placa de proteo ou principal, o
mesmo no comuta;
Comandos Forado:
Este comando no pode ser esquecido no NE, de extrema importncia, que no seja
deixado o equipamento com forado, pois o mesmo, caso haja uma outra falha ele no
comutar.
Retirar os comandos:
Para retirar os comandos basta dar o RELEASE.

TELEMAR

Solues para voc

CGR - CENTRO DE GERNCIA DE REDE - SUPORTE NVEL II TX


TTULO

NE 1660SM - ALCATEL

DATA

12/07/2006

ELABORADO
POR

ANDR GESTEIRA

9-4- Comutaes APS:

Marcar a placa a qual desejamos comutar, ir em EPS > Switch, e ento executar os
comandos.
Forado, Manual, release, etc.
10- Consideraes finais:
Gostaria de informar que esta apostila no esta toda completa, mas qualquer
dvida, ns do suporte de Tx, estamos a para tentar responder as questes.

TELEMAR

Solues para voc

CGR - CENTRO DE GERNCIA DE REDE - SUPORTE NVEL II TX


TTULO

NE 1660SM - ALCATEL

DATA

12/07/2006

ELABORADO
POR

ANDR GESTEIRA

Você também pode gostar