Você está na página 1de 8

PARTE 1

TUBO 5 A (m2)= 0.000222


Vazão L/h Z1 Z0 Vel (vazão/area)
hm (z1-z0) Re f Log (Re)
650 56 49 0.8119 7 18725.51 0.026237 4.2724
950 64 50.2 1.1862 13.8 27358.3 0.023888 4.43789
1250 73.6 50.7 1.5651 22.9 36097.18 0.022365 4.5574
1550 85.7 50.5 1.9395 35.2 44732.51 0.021284 4.65062
1850 99.5 49.5 2.3139 50 53367.37 0.020453 4.7272
2100 112 47.5 2.6296 64.5 60648.62 0.01988 4.7828

TUBO 2 A (m2)= 0.000394


Vazão Z1 Z0 Vel (vazão/area)
hm (z1-z0) Re f Log (Re)
650 63 50.2 0.4567 12.8 14044.33 0.028259 4.43255
950 73 47 0.6673 26 20520.65 0.02564 4.31219
1250 86 41 0.8804 45 27073.85 0.023949 4.43255
1550 102 33 1.091 69 33550.17 0.022753 4.52569
1850 121 21 1.3017 100 40029.56 0.021834 4.60238
2100 142 9 1.4793 133 45491.07 0.021203 4.65793

PARTE 2

Tubo 5 A(m2) = 0.000222


Vazão Z1 Z0 Vel (vazão/area)
hm (z1-z0) Re f log (Re)
100 48.7 48.9 0.12178 -0.2 28087.12 4.44851
250 50 49 0.31123 1 71781.52 4.85601
450 53 49 0.5638 4 13,003 1.110404
650 56.8 49.4 0.8119 7.4 18725.51 4.27243
850 62 50 1.0645 12 24551.43 4.39008
1000 69 50 1.2494 19 28815.93 4.45963
Tubo 4 A(m2) = 0.000113
Vazão Z1 Z0 Vel (vazão/area)
hm (z1-z0) Re f log (Re)
100 56.5 55.2 0.2387 1.3 39323.81 4.59466
250 60 53.5 0.61 6.5 10049.24 4.00213
450 68 49 1.1052 19 18207.24 4.26024
650 78.5 43 1.5915 35.5 26218.62 4.41861
850 92 37.5 2.0866 54.5 34374.97 4.53624
1000 119 40 2.4491 79 40346.85 4.60581

Tubo 3 A(m2) = 0.000227


Vazão Z1 Z0 Vel (vazão/area)
hm (z1-z0) Re f log (Re)
100 55.7 54.8 0.1189 0.9 27749.34 4.44325
250 56.3 55.2 0.2819 1.1 65790.91 4.81817
450 59 55.7 0.5506 3.3 12850.12 4.10891
650 62 55.5 0.7929 6.5 18505.01 4.26729
850 66 56 1.0396 10 24262.59 4.38494
1000 71.5 56 1.22 15.5 28472.83 4.45443
Vazão Z1 Z0 Vel (vazão/area)
hm (z1-z0) Re f log (Re)
650 71.4 68.9 0.2843 2.5 11084.53 0.030103 4.04472
950 75.6 70.4 0.4154 5.2 16195.96 0.027229 4.20941
1250 90 81.5 0.5481 8.5 21369.78 0.025381 4.32980
1550 102 89 0.6793 13 26485.12 4.4230
1850
2100
Calculadora fator de atrito : calculatoratoz.com/pt/friction-factor-for-transitional-turbulent-flow-calculator
Calculadora reynolds :https://www.calculatoratoz.com/pt/reynolds-number-calculator/Calc-1118
DISCENTE: Acsa Lídia damasceno Fernandes Sousa
Disciplina: Laboratorio de EQ 1

Perda de energia em tubulações


PARTE 1

TUBO 5 A (m2)= 0.000222


Vazão L/h Z1 Z0 Vel (vazão/area)
hm (z1-z0) Re f Log (Re)
650 0.56 0.49 0.8119 0.07 18725.51 0.026237 4.2724
950 0.64 0.502 1.1862 0.138 27358.3 0.023888 4.43789
1250 0.736 0.507 1.5651 0.229 36097.18 0.022365 4.5574
1550 0.857 0.505 1.9395 0.352 44732.51 0.021284 4.65062
1850 0.995 0.495 2.3139 0.5 53367.37 0.020453 4.7272
2100 1.12 0.475 2.6296 0.645 60648.62 0.01988 4.7828

TUBO 2 A (m2)= 0.000394


Vazão Z1 Z0 Vel (vazão/area)
hm (z1-z0) Re f Log (Re)
650 0.63 50.2 0.4567 -49.57 14044.33 0.028259 4.43255
950 0.73 0.47 0.6673 0.26 20520.65 0.02564 4.31219
1250 0.86 0.41 0.8804 0.45 27073.85 0.023949 4.43255
1550 1.02 0.33 1.091 0.69 33550.17 0.022753 4.52569
1850 1.21 0.21 1.3017 1 40029.56 0.021834 4.60238
2100 1.42 0.09 1.4793 1.33 45491.07 0.021203 4.65793

TUBO 1
Vazão Z1 Z0 Vel (vazão/area)
hm (z1-z0) Re f log (Re)
650 0.714 0.689 0.2843 0.025 11084.53 0.030103 4.04472
950 0.756 0.704 0.4154 0.052 16195.96 0.027229 4.20941
1250 0.9 0.815 0.5481 0.085 21369.78 0.025381 4.32980
1550 1.02 0.89 0.6793 0.13 26485.12 0.024077 4.4230
1850
2100

PARTE 2

Tubo 5 A(m2) = 0.000222


Vazão Z1 Z0 Vel (vazão/area)
hm (z1-z0) Re f log (Re)
100 0.487 0.489 0.12178 -0.002 28087.12 0.023737 4.44851
250 0.5 0.49 0.31123 0.01 71781.52 0.019161 4.85601
450 0.53 0.49 0.5638 0.04 13003.38 0.02884 1.110404
650 0.568 0.494 0.8119 0.074 18725.51 0.026237 4.27243
850 0.62 0.5 1.0645 0.12 24551.43 0.024526 4.39008
1000 0.69 0.5 1.2494 0.19 28815.93 0.023592 4.45963
Tubo 4 A(m2) = 0.000113
Vazão Z1 Z0 Vel (vazão/area)
hm (z1-z0) Re f log (Re)
100 0.565 0.552 0.2387 0.013 39323.81 0.021924 4.59466
250 0.6 0.535 0.61 0.065 10049.24 0.030919 4.00213
450 0.68 0.49 1.1052 0.19 18207.24 0.026425 4.26024
650 0.785 0.43 1.5915 0.355 26218.62 0.024136 4.41861
850 0.92 0.375 2.0866 0.545 34374.97 0.022623 4.53624
1000 1.19 0.4 2.4491 0.79 40346.85 0.021794 4.60581

Tubo 3 A(m2) = 0.000227


Vazão Z1 Z0 Vel (vazão/area)
hm (z1-z0) Re f log (Re)
100 0.557 0.548 0.1189 0.009 27749.34 0.023807 4.44325
250 0.563 0.552 0.2819 0.011 65790.91 0.019528 4.81817
450 0.59 0.557 0.5506 0.033 12850.12 0.028931 4.10891
650 0.62 0.555 0.7929 0.065 18505.01 0.026316 4.26729
850 0.66 0.56 1.0396 0.1 24262.59 0.024597 4.38494
1000 0.715 0.56 1.22 0.155 28472.83 0.02366 4.45443
Calculadora fator de atrito : https://www.calculatoratoz.com/pt/friction-factor-for-rough-tub
Calculadora reynolds :https://www.calculatoratoz.com/pt/reynolds-number-calculator/Calc-
ction-factor-for-rough-tubes-calculator/Calc-14108
s-number-calculator/Calc-1118

Você também pode gostar