Relatório de Diagnósticos e P1-HIDROMETALURGIA

Recomendações
Issue A page 1 / 2
Preditiva - Vibração

Expertise Report
Filter: Tree order (+) \

Location HIDROMETALURGIA
III\LIXIVIAÇÃO PENEIRAS\
Designation ...
NUMERO DA
Equipment 25PE509-RD ORDEM:
Designation PENEIRA DE TRANSFERÊNCIA
Abbreviation REDUTOR 3842097
Serial No
Model
Periodicity (d) Normal 30 Alarm 15

Previous Advice Condition Rotation Speed


21/08/2020 09:54:14 ATENÇÃO CdP 30 Hz 1800 rpm
21/07/2020 10:44:16 ATENÇÃO CdP 30 Hz 1800 rpm
10/06/2020 10:24:33 ACEITAVEL CdP 30 Hz 1800 rpm
28/04/2020 09:52:48 ACEITAVEL CdP 30 Hz 1800 rpm
25/03/2020 10:46:11 ACEITAVEL CdP 30 Hz 1800 rpm
20/02/2020 12:09:01 ACEITAVEL CdP 30 Hz 1800 rpm
Date CRITICO Speed 30 Hz / 1800 rpm
06/10/2020 12:04:01 Measurement observed shows that vibration levels could Author Diego.Teixeira
generate damages! System - Serial FALCON - 10306
Condition Sensor
CdP Connector
Diagnosis & Recommendation Parameters sheet
Diagnosis
Folga Rotativa
- FALHA DO REDUTOR EVIDENCIADA NOS PARAMETROS DE SINAL DO TEMPO A 14,2 g COM DESTAQUE PARA MODULAÇOES NA
FREQUENCIA DE ROTAÇÃO DO EQUIPAMENTO, CARACTERIZAM A FALHA.

OBS: REDUTOR APRESENTA RUIDO ANORMAL NO CABEÇOTE.


Recommendations
SUBSTITUIR REDUTOR
- DEVIDO A EVOLUÇÃO DOS PARAMETROS DE VIBRAÇÃO RECOEMENDO A TROCA DO REDUTOR E REVISÃO DO CONJUNTO NA
OFICINA CENTRAL.

- VERIFICAR CONDIÇÕES DO ACOPLAMENTO CASO SEJA NECESSÁRIO SUBSTITUI-LO;

560d16.jpg

XPR-300 - 01dB-Metravib Relatório de Diagnósticos e 1/2


Recomendações
Preditiva - Vibração
Relatório de Diagnósticos e P1-HIDROMETALURGIA
Recomendações
Issue A page 2 / 2
Preditiva - Vibração

91384.jpg

XPR-300 - 01dB-Metravib Relatório de Diagnósticos e 2/2


Recomendações
Preditiva - Vibração

Você também pode gostar