Você está na página 1de 2

P1-USINA

<Title>
Issue A page 1 / 2

Expertise Report
Filter: Equipment name (+) \ Tree order (+)

Location HIDROMETRALURGIA\
ELUIÇÃO NÚMERO DA
Designation ... ORDEM:
Equipment 25VE502
Designation FOLGA MECÂNICA 4709378
Abbreviation
Serial No
Model
Periodicity (d) Normal 30 Alarm 15

Previous Advice Condition Rotation Speed


31/11/2022 10:26:17 ATENÇÃO DfCnd 60 Hz 1200 rpm
27/10/2022 11:23:48 ACEITAVEL DfCnd 60 Hz 1200 rpm
20/09/2022 13:22:26 ACEITAVEL DfCnd 60 Hz 1200 rpm
04/08/2022 15:09:46 ACEITAVEL DfCnd 60 Hz 1200 rpm
31/07/2022 15:05:51 ACEITAVEL DfCnd 60 Hz 1200 rpm
19/06/2021 10:52:59 ACEITAVEL DfCnd 60 Hz 1200 rpm
Date ATENÇÃO Speed 60 Hz / 1200 rpm
16/12/2022 10:32:05 Health is good for a long time service without Author Mateus.Cipriano
Condition restriction. System - Serial FALCON - 10306
DfCnd Sensor
Connector
DIAGNOSTICO E RECOMENDAÇÃO Parameters sheet
DIAGNOSTICO

FALHA DE FOLGA MECÂNICA ROLAMENTO LOA DO MANCAL DO VENTILADOR

O EQUIPAMENTO ENCONTRA-SE EM STATUS DE ATENÇÃO DEVIDO A CARACTERISTICA ESPECTRAL APRESENTANDO EVOLUÇÃO 113%
EM SINAL NO TEMPO E VIBRAÇÃO COM MÚLTIPLOS HARMÔNICOS DA ROTAÇÃO, PROVENIENTE DE FOLGA MECÂNICA NO ROLAMENTO
E CAIXA DE MANCAL LOA.

RECOMENDAÇÕES

SUBSTITUIR ROLAMENTOS LA E LOA DO VENTILADOR

RECOMENDAMOS SUBSITUIR ROLAMENTOS LA E LAO DO VENTILADOR E INPECIONAR EIXO E CAIXAS DE MANCAIS QUANTO À
DESGASTES / FOLGAS E CORRIGIR ALINHAMENTO ENTRE AS POLIAS COM ALINHADOR À LASER.

400f4.jpg

XPR-300 - 01dB-Metravib <Title> 1/2


P1-USINA
<Title>
Issue A page 2 / 2

Figura 1: Gráfico em tendência em sinal no tempo, com evolução de 113 % nos níveis vibracionais e operando, com 27 G.

1xRPM e
HARMONICOS

Figura 2: Espetro em envelope, com excitação da frequência de 1xrotação e múltiplos harmônicos caracterizando folga mecânica no rolamento LOA do
ventilador.

XPR-300 - 01dB-Metravib <Title> 2/2