Você está na página 1de 22

33547/0343008

DJ 145kV 2000A TRI MOT SF6 EXT 40kA


CAPA
NEOENERGIA .
ÍNDICE
FOLHA
TÍTULO REVISÃO OBSERVAÇÕES

01 CAPA 00
02 ÍNDICE 00
03 FOLHA DE DADOS 00
04 FOLHA DE DADOS 00
05 FOLHA DE DADOS 00
06 FOLHA DE DADOS 00
07 FOLHA DE DADOS 00
08 FOLHA DE DADOS 00
09 EMBALAGEM 00
10 DIMENSIONAL - DISJUNTOR 00
11 DIMENSIONAL - ESTRUTURA SUPORTE 00
12 DIMENSIONAL - DETALHE DE FIXAÇÃO 00
13 PLACAS DE IDENTIFICAÇÃO 00
14 ISOLADOR SUPORTE 00
15 UNIDADE INTERRUPTORA 00
16 PROCESSO DE PROTEÇÃO ANTICORROSIVO 00
17 PROCESSO DE PROTEÇÃO ANTICORROSIVO 00
18 PIT – PLANO DE INSPEÇÃO E TESTES 00
19 PIT – PLANO DE INSPEÇÃO E TESTES 00
20 PIT – PLANO DE INSPEÇÃO E TESTES 00

33547/0343008
DJ 145kV 2000A TRI MOT SF6 EXT 40kA
ÍNDICE
NEOENERGIA .
DJ-33547-0343008-12070011-SIEMENS-EM

FOLHA DE DADOS
DJ 145kV 2000A TRI MOT SF6 EXT 40kA

33547/0343008

DISJUNTOR TRIPOLAR A SF6


PARA USO EXTERNO

Código SAP: 33547/0343008 – DJ 145kV 2000A TRI MOT SF6 EXT 40kA Nº Siemens: 4HD D0027.1062/21
Título Documento: FOLHA DE DADOS Folha: 3/20
LIVE TANK CIRCUIT-BREAKERS
INFORMATION TO BE PROVIDED BY THE SUPPLIER NEOENERGIA
Code (see Annex A3) 343008/33547 343008 / 33547

Designation (see Annex A3) LTB 1P 145KV 2000 A 40 KA EXT LTB 3P 145KV 2000A 40KA EXT
Manufacturer/supplier Supplier Information Siemens
Local of manufacture Supplier Information Jundiai/SP
Manufacturing period Supplier Information Até 6 meses
Test Site Supplier Information Jundiai/SP
1- CONDITIONS IMPOSED BY THE POWER SYSTEM REQUIRED TENDERED
System rated voltage (kV) 138 138kV
System maximum operating voltage (kV) 145 145kV
Rated frequency (Hz) 60 60
System earthing (effectively /non-effectively) Effectively effectively
2-CLIMATIC AND ENVIRONMENT CONDITIONS REQUIRED TENDERED
Ambient air maximum temperature (ºC) 40 40ºC
Temperature average value measured for a period of 24 hours (ºC) 25 ≤ 35 ºC
Minimum temperature (ºC) -10 -5ºC
Relative humidity (%) <95 90%
Maximum sun radiation (W/m2) 1000 1.000 W/m2
Maximum altitude of installation place (m) 1000 1.000 m
Ice coating (mm) N/A N/A
Ambient air polluted with dust, smoke, corrosive gases, vapours or salt (Y/N) Supplier Information Não
Pollution degree (d, e) d d
Specific length of leakage path (mm/kV) 43,3 25mm/kV
Atmosphere aggression degree N/A N/A
velocidade do vento de até 34 m/s (122
Wind maximum speed (m/s) 34
km/h).
Seismic conditions – earthquake intensity (g) N/A N/A
Condensation or precipitations consideration (Y/N) YES Sim
3-MAIN CHARACTERISTICS REQUIRED TENDERED
Installation place (outdoor/indoor) OUTDOOR Outdoor
Circuit-breaker design (live tank/dead tank) LIVE TANK Live Tank
Number of pole 3 3

Unrestricted # Internal Use


Circuit-breaker pole operation TRIPOLAR Tripolar
Stored energy operating mechanism (Y/N) YES Sim
Energy storage device SPRING DRIVE A mola
Manual and motorised spring charging (Y/N) YES Sim
Manual and electric energy release (Y/N) YES Sim
Mechanical device provided to prevent over-charging of the closing springs for manual charging
YES Sim
(Y/N)
Safe condition produced in case of failure to latch (Y/N) YES Sim
Circuit-breaker interrupting technology SF6 (Y/N) YES Sim
Operating mechanism, degree of protection for enclosures (IP) IP55 IP-54
Operating mechanism, degree of protection for open areas (IP) IP55 IP-54
Operating mechanism enclosure material Supplier Information Aço Carbono
Main terminal type (Flat pad/Steam) Supplier Information Flat
Flat pad details:
Nema 8
- Number of hole and pitch (mm) - Minimum thickness (mm) - Material Supplier Information
Steam details: - Diameter (mm) - Length (mm) - Material Supplier Information Ø14 / 228x207x20
Earthing terminals Supplier Information Incluso
Number of interrupting chambers in serie per pole 1 1
Classification as for mechanical endurance class (M1/M2) M2 M2
Classification as for electrical endurance (E1/E2) E1 E1
Classification as for S1/S2 S2 N/A
Restrike performance during capacitive current switching (C1/C2) C2 C2
Controlled switching (Y/N) NO Não
Grading capacitors required (Y/N) Supplier Information Não
4-ELECTRICAL CHARACTERISTICS REQUIRED TENDERED
Rated voltage (kV) 145 145kV
Rated power-frequency withstand voltage (kV) 275 275kV
Rated lightning impulse withstand voltage to earth (kV) 650 650kV
Rated switching impulse withstand voltage to earth (kV) 750 650kV
Rated frequency (Hz) 60 60
Rated normal current (A) 1250 2000
Rated short-time withstand current (kA) 40 40kA
Rated peak withstand current (kA) 104 104

Unrestricted # Internal Use


Rated duration of short-circuit (s) 1 3s
Rated d.c. supply voltage of closing and opening device and of auxiliary and control circuits (V) 125 125
Rated a.c.supply voltage of heaters and other a.c. auxiliary circuits (V) 220 FF/FN 220 FF/FN
Rated short-circuit breaking current (kA) 40 40kA
First-pole-to-clear factor 1,5 1,5
DC time constant (ms) Supplier Information 45 ms
DC component (%) Supplier Information 46,60%
Transient recovery voltage for terminal faults (kVpeak) Supplier Information 249kV
Rated short circuit making current (kApeak) 104 104kA
Rated operating sequence O-0,3s-CO-1min-CO O-0,3s-CO-1min-CO
Minimum resting time following rated operation sequence (min) Supplier Information 240 minutos
- Surge Impedance 450 ohms
Characteristic for short-line fault Supplier Information
- Peak Factor 1.6
Rated out-of-phase making and breaking current (kA) Supplier Information 10kA
Classification according to the restrike performance Supplier Information C1 for line Charging
Rated capacitive switching current for line-charging breaking current (A) Supplier Information 50A
Rated capacitive switching current for cable-charging breaking current (A) Supplier Information 160A
Rated capacitive switching current for single capacitor bank breaking current (A) Supplier Information NA

Rated capacitive switching current for back-to-back capacitor bank breaking current (A) Supplier Information NA

Rated capacitive switching current for back-to-back capacitor bank inrush making current (kApeak) Supplier Information NA
Inductive load breaking current (A) Supplier Information NA
Asymmetrical short-circuit interrupting capability 104 83kAp
na abertura ≤2,7 ms
Pole discordance ≤8,3 ms
no fechamento ≤4,2 ms
na abertura ≤2,7 ms
Requirements for simultaneity of poles during single closing/opening operations Supplier Information
no fechamento ≤4,2 ms
Auto-reclosing (Y/N) YES Sim
Rated opening time (ms) Supplier Information 29 ± 3 ms
Rated break-time (ms) ≤83,3 ms 300 ms
Rated close time (ms) Supplier Information 64±6 ms
5- CONSTRUCTIONAL FEATURES REQUIRED TENDERED
Height (mm) Supplier Information 5721
Net weight of one complete circuit-breaker (Kg) Supplier Information 1300

Unrestricted # Internal Use


Creepage distance (mm/kV) 25,5 25mm/kV
Insulator material (porcelain/composite) Porcelain Porcelana
Insulator colour Supplier Information Marron
Minimum clearances in air: - Between poles. Supplier Information 1700mm
- Between pole to earth. Supplier Information 1250mm
Suitable for trip-free or fixed trip Supplier Information trip-free
Provided with a lock-out device (Y/N) YES No
Operating mechanism number of drives 3 1
Motor charged spring operating mechanism 3 one spring mechanism
Operating Voltage (VDC) 125 125
Heater Voltage (VAC) 220 FF/FN 220 FF/FN
Motor voltage (VDC) 125 125
Power required at rate supply voltage by Closing coil (W) Supplier Information 110/125 Vcc - 242/312 W
Power required at rate supply voltage by Opening coil (W) Supplier Information 110/125 Vcc - 242/312 W
Power required at rate supply voltage by Motor (kW) Supplier Information 125Vcc - 438 W
Power required at rate supply voltage by heating element continuously (W) Supplier Information 1500 Ω / 35 W

Power required at rate supply voltage by heating elements connected by thermostat (W) Supplier Information 0 a 60°C 250 V 10 A

Rated supply voltage of shunt opening release Supplier Information 125 Vcc
Current required at rated supply voltage for shunt opening release Supplier Information 312 W/125 Vcc
according
Current required at rated supply voltage by other auxiliaries Supplier Information
electric diagram
Number and type of spare auxiliary switches 5NO/5NC 5NA + 5NF
Number of releases for tripping, if more than one 2 2
Number of releases for closing, if more than one. 1 1
Gas mixture Supplier Information N/A
Total mass of gas (kg) Supplier Information 6.5 kg
Volume of gas (litre) Supplier Information 140.4 litros
Max. Working pressure (Mpa) (realative) Supplier Information 6.0 bar
Filling pressure at +20ºC (Mpa) (relative) Supplier Information 6.0 bar
Level 1 for low gas density alarm (Mpa) (relative) Supplier Information 5.2 bar
Level 2 for inadmissible SF6 gas density alarm (Mpa) (relative) Supplier Information 5.0 bar
Sim - Aço Galvanizado de acordo com a
Steel support structure to be supplied with circuit-breaker (Y/N) YES
norma NBR 6323.

Unrestricted # Internal Use


6-MECHANICAL CHARACTERISTICS REQUIRED TENDERED
Failing load - Bending (N) Supplier Information
Força admissivel nos terminais do disjuntor.
Failing load - Torsion (Nm) Supplier Information Longitudinal: 1250N
Maximum allowable terminal loadings Supplier Information Transversal: 750N
Vertical: 1000N
Minimum mechanical failing load, tension (kN) Supplier Information

Não está sendo previsto:


1) peças sobressalentes.
2) Grau de proteção dos armarios de
comando e acionamento são IP-54.
3) Os disjuntores apresentados não são
aplicados para manobra de banco de
capacitores.
4) Todas as peças galvanizadas atenderá a
camada média de 120um e minima de
Deviations from The Company specification
80um.
5) Para a pintura dos armarios, estamos
considerando o padrão de pintura P2 -
Eletrobrás, propria para ambientes
agressivos.
7) Os parafusos, porcas e arruelas serão
fornecidos em aço galvanizado.
8) Não estamos considerando custo de
transporte e translado para inspetor

Unrestricted # Internal Use


33547/0343008
DJ 145kV2000A TRI MOT SF6 EXT 40kA
EMBALAGEM
NEOENERGIA .
·

NEOENERGIA

33547/0343008
DJ 145kV 2000A TRI MOT SF6 EXT 40kA

DIMENSIONAL - DISJUNTOR
.

.
.
33547/0343008
DJ 145kV2000A TRI MOT SF6 EXT 40kA
DIMENSIONAL - ESTRUTURA SUPORTE
NEOENERGIA .
33547/0343008
DJ 145kV 2000A TRI MOT SF6 EXT 40kA
DIMENSIONAL - DETALHE DE FIXAÇÃO
NEOENERGIA .
33547/0343008
DJ 145kV 2000A TRI MOT SF6 EXT 40kA
PLACAS DE IDENTIFICAÇÃO
NEOENERGIA .
33547/0343008
DJ 145kV 2000A TRI MOT SF6 EXT 40kA
ISOLADOR SUPORTE
NEOENERGIA .
33547/0343008
DJ 145kV 2000A TRI MOT SF6 EXT 40kA
UNIDADE INTERRUPTORA
NEOENERGIA .
DJ-33547-0343008-12070011-SIEMENS-EM

PROCESSO DE PROTEÇÃO ANTICORROSIVO


DJ 145kV 2000A TRI MOT SF6 EXT 40kA

33547/0343008

DISJUNTOR TRIPOLAR A SF6


PARA USO EXTERNO

Código SAP: 33547/0343008 – DJ 145kV 2000A TRI MOT SF6 EXT 40kA Nº Siemens: 4HD D0308.1062/21
Título Documento: PROCESSO DE PROTEÇÃO ANTICORROSIVO Folha: 16/20
Pintura – Disjuntores de Alta Tensão
Flange dos
Isoladores, Armários de Peças e
Partes do Estrutura
Terminal de alta Viga Base acionamento acessórios de
Disjuntor Suporte
tensão e anéis e auxiliar embalagem
anti-corona
Material: aço Material: aço
liga de alumínio carbono PÓ carbono
sem revestimento Zincagem por (Esquema P2 Zincagem por
ESQUEMA
(oxidação protetiva imersão a quente da imersão a quente
natural) Conforme: NBR Eletrobrás) Conforme: NBR
6323 6323

Preparo da decapar e
Conf. NBR 6323 Conf. NBR 6323 desengraxar
Superfície fosfatizar

Epóxi-
Epóxi em pó
poliamida
pigmentadas
pigmentada
Pintura de Fundo com zinco
com fosfato de
metálico em
zinco e óxido

de ferro
No Demão 1 2
Espessura por
80 µm 20 ± 5 µm
Demão

Resina de
Pintura Final poliéster em

No Demão 1
Espessura por
90 µm
Demão
Espessura Total do Mínimo 170
40 ± 10 µm
Filme Seco µm

Poliuretano
Retoque alifático
No Demão 1
Espessura por
40 ± 5 µm
Demão

Grau de aderência GR – 01
Cinza
Cor
Munsell N 6,5
Espessura do Conforme NBR 7399 Conforme NBR 7399
revestimento da Mínima: 80 µm Mínima: 80 µm
Camada de Zinco Média: 120 µm Média: 120 µm

Esquema P2 (referência Eletrobrás – Tipo de exposição/ambiente: Atmosfera agressiva)

Gerência Corporativa de Normalização de Subestações Folha: 17/20


DJ-33547-0343008-12070011-SIEMENS-EM

PIT – PLANO DE INSPEÇÃO E TESTES


DJ 145kV 2000A TRI MOT SF6 EXT 40kA

33547/0343008

DISJUNTOR TRIPOLAR A SF6


PARA USO EXTERNO

Código SAP: 33547/0343008 – DJ 145kV 2000A TRI MOT SF6 EXT 40kA Nº Siemens: 4HD D0007.1062/21
Título Documento: PIT – PLANO DE INSPEÇÃO E TESTES Folha: 18/20
Item COMPONENTE CONTROLES E ENSAIOS Tipo Insp. OBSERVAÇÕES
1 2 3
1 Disjuntor
1.1 - Verificações gerais: F P - Conforme Norma NBR IEC 62271-100
a) Placas de Identificação;
b) Equipamentos auxiliares;
c) Isoladores;
d) Mecanismo de operação;
e) Principais dimensões do disjuntor e do mecanismo de operação;
f) Conformidade e endereçamento da fiação elétrica com verificação ponto-a-ponto, do mecanismo
de operação;
g) Simulação de funcionamento do mecanismo de operação;
h) Valores dos resistores e capacitores ligados ao circuito principal (se aplicável);
i) Conexões;
j) Terminais e conetores de aterramento;
k) Verificação da atuação dos pressostatos, densímetros, etc;
l) Verificação do sistema de carregamento das molas.

1.2 - Ensaios de operação mecânica nas tensões máximas, mínimas e nominal: F P - No caso de disjuntores com comando
5 Fechamentos ( C ) e 5 Aberturas ( O ) com 110% Un. hidráulicos ensaios com pressão máxima,
5 Fechamentos ( C ) e 5 Aberturas ( O ) com 80% Un. minima e nominal.
5 Fechamento / Abertura ( CO) com 100% Un.
5 Abertura / Fechamento ( O - t - C) com 100% Un.
1.3 - Verificação de tempo e corrente no motor com tensões máx., mín. e nominal F P C
1.4 - Controle dos alarmes/bloqueios do sistema de gás SF6 (densímetro) F P C Para disj. FA apresentação de certificado
1.5 - Controle dos valores de atuação dos pressostatos (se aplicavel) F/L P C/E Para disjuntores com comando hidráulico
1.6 - Medição dos tempos de operação C, O1, O2, CO, OCO nas tensões nominais e F P C
O1, O2 e C com tensão e pressão hidráulica mínima e máxima
1.7 - Verificação do sincronismo dos contatos F P C
1.8 - Ensaio de verificação da tensão suportável à freqüência industrial, a seco, no circuito principal F P C Para disjuntores FA ensaio a 165 kV com
Para disjuntores até 245 kV (inclusive) 0,3bar de SF6.
1.8.1 • Ensaio realizado sobre o disjuntor completo com tensão plena
Para disjuntores acima de 245 kV
1.8.2 • Ensaio realizado nas câmaras com tensão proporcional
• Fornecimento de certificado das hastes isolantes e isoladores de porcelanas S S C

1.9 - Ensaio de verificação da tensão suportável à freqüência industrial, a seco, nos circuitos de F P C
comando e auxiliares. Para os densímetros este ensaio é realizado no fornecedor com apresentação
de certificado.
1.10 - Medição da resistência ôhmica dos contatos F P C
1.11 - Medição da resistência de isolamento (Megômetro) nos circuitos auxiliares F P C
1.12 - Ensaio funcional F P -
1.13 - Ensaio de controle de estanqueidade F P C Conforme procedimento interno
1.14 - Ensaios sobre a pintura e zincagem F P - Conforme norma interna / NBR 11003
1.15 - Ensaio sobre capacitores de equalização (se aplicável) – apresentação de certificados do S S C
fornecedor

Gerência Corporativa de Normalização de Subestações Folha: 19/20


2 Estrutura suporte
2.1 e Plataforma de - Dimensional F P -
2.2 acesso - Verificação da espessura da camada de zinco F P C/E Conforme NBR 7399
2.3 - Verificação da pintura (se aplicável) F P - Conforme NBR 11003 (aderência)
1 2 3 OBS.:
TIPO DE Local de Inspeção Inspeção Certif. ou Relat. Enaios - Norma de referência: NBR IEC 62271-100
INSPEÇÃO F = Fabricante P = Na presença do cliente C = Entrega p/ Registro
L = Laboratório independente S = Sem presença do cliente E = Exame / Análise
S = Subfornecedor - = Não aplicável - = Não aplicável
- = Não aplicável

Gerência Corporativa de Normalização de Subestações Folha: 20/20

Você também pode gostar