Designation ... Número da
Equipment 25BO523
Designation BOMBA DE POÇO
ordem:
Abbreviation
Serial No
MANCAL 4698237
Model
Periodicity (d) Normal 30 Alarm 15
Fabricante: Weir
Vazão:24m/ n
Atm:31 mcl
Rotação:1486
Fluido:agua drenagem piso
Rotor:SP65206A
SKF 22213C
SKF 22220E
Previous Advice Condition Rotation Speed
16/10/2022 11:12:30 ATENÇÃO DfCnd 60 Hz 3600 rpm
22/09/2022 11:31:04 ACEITAVEL DfCnd 60 Hz 3600 rpm
17/08/2022 15:10:18 ACEITAVEL DfCnd 60 Hz 3600 rpm
27/07/2022 13:31:07 ACEITAVEL DfCnd 60 Hz 3600 rpm
04/06/2022 15:40:29 BOM DfCnd 60 Hz 3600 rpm
29/05/2022 11:02:51 BOM DfCnd 60 Hz 3600 rpm
Date ATENÇÃO Speed 60 Hz / 3600 rpm
04/11/2022 14:22:46 SAUDE NÃO ACEITAVEL POR UM LONGO PERIODO DE Author Diego.Teixeira
FUNCIONAMENTO. System - Serial FALCON - 10306
Condition Sensor
DfCnd Connector
DIAGNOSTICO E RECOMENDAÇÃO Parameters sheet
Diagnostico
FOLGA ESTRUTURAL
Recomendação
FIXAR BOMBA, BASE METALICA E PROTEÇÃO DAS POLIAS
- RECOMENDO AINDA QUE SEJA REALIZADA A SUBSTITUIÇÃO DAS CORREIAS, ALINHAMENTO DAS
POLIAS BEM CHECAGEM E FIXAÇÃO DO CONJUNTO.
311cc.jpg