Escolar Documentos
Profissional Documentos
Cultura Documentos
AO
1-
13-52[0]
2-
13-52[1]
3-
13-52[2]
4-
13-52[3]
Run [22]
TEMPORIZADORES TIMERS
13-20 TIMER[0] 00.00.05.000
13-00 ON[1]
Comparador
Corrente do Motor
Timer 0
SLC=Smart Logic Controller
Estados
EVENTO
AO
1-
TRUE
Run
2-
Comparator 0
Start Timer 0
3-
TRUE
Run Reverse
4-
SL Timer Out 0
Run
AES
Estado 1
[1]
TRUE
Run
[22]
Estado 2
[22]
Comparator 0
Start Timer 0
[29]
Estado 3
[1]
TRUE
Run Reverse
[23]
Estado 4
[30]
SL Timer Out 0
Run
[22]
TEMPORIZADOR TIMER 0
Par. 13-20 TIMER[0] 00.00.05.000
COMPARADOR COMPARATOR 0
Par. 13-10 OPERANDO DO COMPARATOR[0] = [4]=MOTOR CURRENT
Par. 13-11 OPERADOR DO COMPARATOR = [2]
Par. 13-12 VALOR DO COMPARATOR = 4,5
13-00 ON[1]
>
AO
13-51
13-52
0-
[1]
TRUE
Run [22]
1-
[26]
Logic Rule 0
Start Timer 0
[29]
2-
[1]
TRUE
Run Reverse
[23]
3-
[30]
SL Timer Out 0
Run [22]
TEMPORIZADOR TIMER 0
Logic rule
13-40.0=22
COMPARADOR COMPARATOR 0
Par. 13-10 OPERANDO DO COMPARATOR[0] = [4]=MOTOR CURRENT
Par. 13-11 OPERADOR DO COMPARATOR = [2]
Par. 13-12 VALOR DO COMPARATOR = 4,5
13-00 ON[1]
>
13-41.0=1
13-42.0=34
Regra Lgica 1
Se a corrente do motor for maior que um "certo" valor e o terminal 19 estiver
fechado o relay 1 ser energizado, e se for falsa a lgica 1 o relay fica aberto.
AO
0-
[1]
TRUE
Run [22]
1-
[23]
Comparador 1
Start Timer 0
[29]
2-
[1]
TRUE
Run Reverse
[23]
3-
[30]
SL Timer Out 0
Run [22]
[1]
Reset Contador A [ 60 ]
TRUE
13-00 ON[1]
>