Você está na página 1de 42

Pontficia Universidade Catlica de Gois - Curso de Graduao Engenharia Ambiental Disciplina: Tratamento de Resduos Lquidos I e II

_________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ __ _______________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________

___________________________________________________________________________ __________________________________________________________ _______________________________________ ____________________ _______

OPERAO DE ETE / ETDI


(Recomendaes bsicas) _______ _______ ____________________ _______________________________________ __________________________________________________________ ___________________________________________________________________________

_________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ________ _________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ _____

Srie Material de apio

Professor: Eng Osmar Mendes Ferreira, Ms

Pontifcia Universidade Catlica de Gois - Curso de Graduao Engenharia Ambiental Disciplina: Tratamento de Resduos Lquidos I e II

_________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ __ _______________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________

ANEXO I

1. Recomendaes preliminares Aps a concluso das obras e servios relativos implantao de todas as unidades constituintes do projeto, dever ser realizado teste de funcionamento, onde todas as unidades do tratamento fsico e biolgico devero ser preenchidas com gua limpa, verificando-se nesta oportunidade, todo fluxo hidrulico e sua estanqueidade, bem como o funcionamento dos equipamentos eletromecnicos. A operao da planta deve ser feita diariamente e assistida pr tcnico habilitado para o desenvolvimento destas tarefas, devendo receber treinamento e estar ligado diretamente ao departamento de operao e manuteno da empresa, com a superviso do responsvel tcnico de nvel superior, bem como ter o apoio do laboratrio de controle de qualidade desta, na realizao das anlises mais simples e corriqueiras. A qualificao do operrio fundamental para o sucesso da operao do projeto. importante que este tenha o segundo grau completo, e preferencialmente que esteja continuando a estudar e demonstre interesse e aptido para o trabalho, e que venha a se aperfeioar, participando de cursos sobre operao e manuteno de Estao de Tratamento de Esgoto. A remunerao bsica acrescida de insalubridade um estimulo para o bom desempenho de suas funes. Em todo processo, indispensvel a manuteno da higiene e limpeza em toda rea da Estao de Tratamento dos Esgotos. Sempre que possvel renovar a pintura dando ateno especial nas partes metlicas, que esto mais sujeitas ao desgaste, Estes cuidados, causam boas impresses aos visitantes e torna o ambiente de trabalho agradvel e mais seguro. 2. Tratamento preliminar / primrio So destinados para promover a remoo de slidos grosseiros, materiais inertes de peso especfico maiores que o da gua, bem como os materiais grosseiros. . 2.1 Gradeamento Unidade destinada para a remoo de materiais grosseiros. O material retido nas grades dever ser removido com uma freqncia de modo a evitar que o aumento da perda de carga localizada nas barras cause represamento dos esgotos no canal a montante e aumento demasiado da velocidade do lquido entre as barras, arrastando alguns materiais que deveriam ser retidos nessa unidade. A limpeza manual realizada com um ancinho (rastelo). Deve ser feita segundo as especificaes do projeto, geralmente quando estiver com 50% de sua altura til ocupada com a reteno de material, ou quantas vezes forem necessrias ao dia, ou segundo observaes prticas. conveniente tambm que, antes de se colocar o material removido no recipiente, os resduos sejam escorridos, para diminuir o excesso de gua. 2.2.1 Atividades peridicas do operador

_________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ________ _________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ _____

Srie Material de apio

Professor: Eng Osmar Mendes Ferreira, Ms

Pontifcia Universidade Catlica de Gois - Curso de Graduao Engenharia Ambiental Disciplina: Tratamento de Resduos Lquidos I e II

_________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ __ _______________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________

a) Dar pancada, de hora em hora, na grade com rastelo apropriado; b) Passar o material gradeado para um crivo, construdo sobre o canal a jusante da grade, a intervalos mximo de trs horas. Neste local, o material poder ser lavado, com esguicho de mangueira, livrando-o de toda sua matria orgnica no grosseira, reduzindo-se, ento, o seu volume; c) Todas as manhas, o material j lavado e escoado, dever ser depositado em valas apropriadas e recoberto com pequena camada de terra, para que seja digerido fora do acesso de insetos, especialmente das moscas. Ou encaminhado para a disposio em aterro sanitrio. 2.2. Caixa desarenadora de canal duplo A caixa desarenadora destinada para reter substncias inertes, como areias e slidos minerais sedimentveis. Portanto, so dispositivos empregados para remover materiais inorgnicos, no putrescveis, caracterizando-se como partculas com tamanhos superiores a 0,2 mm que no floculam e possuem uma velocidade de sedimentao maior que as partculas orgnicas. A limpeza manual realizada com uma p deve ser feita segundo as especificaes do projeto, ou uma vez por dia ou mais se necessrio, ou segundo observaes prticas verificando-se quando estiver com 2/3 de assoreamento do poo de areia. conveniente tambm que, antes de se colocar o material removido no recipiente, os resduos sejam escorridos, para diminuir o excesso de gua.

2.2.2 Atividades peridicas do operador a) Agitar trs vezes por dia, a caixa desarenadora no sentido contrrio ao fluxo dos esgotos, forando, desse modo, a matria orgnica que por ventura tenha sedimentado (especialmente nas horas de menor vazo), a voltar ao meio lquido e a ser transportada a outras unidades, dimensionadas para receber esse tipo de slido, lagoas de estabilizao ou outro sistema de tratamento biolgico, por exemplo; b) Realizar a descarga ou limpeza da caixa desarenadora sempre que o material acumulado ocupar a metade da altura da cmara de armazenamento ou 2/3 de todo seu cumprimento. Os intervalos entre as limpezas no devem ser superior a sete dias. interessante observar que: O projeto deve conta com duas cmaras da caixa desarenadora, pois dessa forma, uma deve estar isolada para a limpeza, enquanto a outra colocada em funcionamento; A areia, bem como o material sedimentado nessa unidade, depois de retirado por meio de ps ou enxada deve ser transportada e, convenientemente enterrada; A cmara depois de lavada esta pronta para ser reutilizada. 2.3. Medidor de vazo Sempre que possvel, dispor de registradores de vazo afluente ou realizar medies horrias que cubram pelo menos o perodo diurno. Quando isso for possvel, optar por leituras s 7:00 h, 9:00 h, 12:00 h, 13:00 h 15:00 h, 18:00 h e 21:30 h. O operador deve, antes de cada leitura, limpar as calhas vertedouros, e/ou, o canal afluente ao dispositivo de medio, impedindo qualquer interferncia no fluxo que possa prejudicar as leituras. Os valores medidos devem ser anotados na ficha diria de controle operacional.

_________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ________ _________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ _____

Srie Material de apio

Professor: Eng Osmar Mendes Ferreira, Ms

Pontifcia Universidade Catlica de Gois - Curso de Graduao Engenharia Ambiental Disciplina: Tratamento de Resduos Lquidos I e II

_________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ __ _______________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________

2.4. Caixa de remoo de material gorduroso caixa de gordura Unidade destinada para remoo dos slidos gordurosos com peso especfico menor que o da gua. O sistema tem como base a flotao forada do material gorduroso, pelo percurso do fluxo hidrulico do efluente, seguindo por chicanas que determinam a direo horizontal/vertical, promovendo a aglutinao das partculas gordurosas que flutuam e so retirados na superfcie. Aps a retirada do material sobrenadante, deve-se abrir o registro de fundo para o escoamento da gua. Essa abertura deve ser lenta de modo a no carrear os slidos que possivelmente esteja decantado no fundo. Os slidos decantados devero ser recolhidos e encaminhados para em aterro sanitrio. Todo material gorduroso removido do sistema deve ser depositado em reservatrio de gordura apropriado (tambor), dando-se a destinao adequada, geralmente conduzida ao aterro sanitrio. A limpeza diria desta unidade eliminar focos de moscas e de maus odores. 2.5. Peneira esttica Unidade destinada remoo de slidos com dimetro superior a malha das peneiras (geralmente de 0,5 a 2,0 mm). Durante todo perodo de operao, deve ser observada possveis obstrues da peneira que deve ser escovada e direcionado jatos de gua com alta presso, para a retirada de todo material que tenha ficado retido entre as ranhuras da tela da peneira, causando sua obstruo. 3. Avaliao do Desempenho Providenciar anlise dos afluentes e efluentes mensalmente, e/ou, com maior freqncia se for necessrio, para verificar a reduo da Carga de DBO. A eficincia prevista expressa em percentagem na reduo da Carga de DBO pode ser calculada observando que. A eficincia parcial ou total esperada pode ser expressa em percentagem (E), e obtida conforme a formula: E = X - Y x 100 (%) X X, o parmetro inicial ou na forma bruta. Y, o parmetro final ou tratado.

3.1 Parmetros a serem analisados

Devem ser recomendados a realizao de Anlises Ambientais daqueles parmetros estabelecidos pela legislao ambiental em nvel federal, estadual e municipal quando for o caso, segundo a tipologia da atividade que deu origem ao esgoto a ser tratado. Ainda recomendada a realizao das anlises dos parmetros mnimos para controle de efluentes lquidos, apresentados pela NBR 9897 (ABNT, 1987). Estes devem ser realizados pela prpria empresa, quando dispuser de laboratrio especifico, ou ser solicitado sua realizao em laboratrios credenciados.
_________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ________ _________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ _____

Srie Material de apio

Professor: Eng Osmar Mendes Ferreira, Ms

Pontifcia Universidade Catlica de Gois - Curso de Graduao Engenharia Ambiental Disciplina: Tratamento de Resduos Lquidos I e II

_________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ __ _______________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________

Tabela 1: Exemplo dos parmetros a serem analisados para controle operacional de estao de tratamento de esgoto urbano Acidez Dureza N-Orgnico Alcalinidade Fosfatos N-Total Alumnio Fsforo total leos e Graxas Carbanato orgnico total Materiais flutuantes Organoclorados Cloretos Mercaptans pH Coliformes fecais Mercrio Slidos sedimentaveis Coliformes totais Nquel Slidos dissolvidos Cor N-Amoniacal Slidos no filtrveis 20 DBO 5 C N-Nitrato Slidos totais DQO N-Nitrito Sulfatos Sulfetos Sufactantes Temperatura Turbidez Fonte: NBR 9897 (ABNT, 1987).

3.2 Pontos de coleta para anlise Efluente bruto, coleta composta; Efluente tratado, coleta simples.

Melhores pontos para coleta das amostras. Efluente bruto, na entrada da ETE; Aps o tratamento preliminar; Aps a unidade de tratamento fsico-qumico (quando for o caso); Aps a unidade de tratamento biolgico; Efluente tratado.

3.3 Danos Aparentes na Estao de Tratamento de Esgoto Alta carga; Geralmente acontece pr limitaes dos projetos iniciais ou simplesmente pr ampliaes da rea atendida pelo projeto, com aumento da vazo e da carga orgnica afluente, desconsiderando o projeto original. Tais conseqncias produzem danos ao meio ambiente, descartando esgoto sem tratamento. 4 rea do sistema -

Deve ser cercada para evitar o acesso de estranhos no local; Gramado; a grama deve ser aparada e molhada com freqncia; Sinalizado, com placas de advertncia com os dizeres REA DE RISCO, PROIBIDO A
ENTRADA DE PESSOAS ESTRANHAS

5. Sade pblica e segurana As lagoas de estabilizao como qualquer outro sistema de tratamento de esgoto, precisam ser consideradas com muita cautela do ponto de vista da sade pblica, tanto pelos operadores
_________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ________ _________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ _____

Srie Material de apio

Professor: Eng Osmar Mendes Ferreira, Ms

Pontifcia Universidade Catlica de Gois - Curso de Graduao Engenharia Ambiental Disciplina: Tratamento de Resduos Lquidos I e II

_________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ __ _______________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________

quanto pela populao das circunvizinhaa. Para reduzir os impactos no meio ambiente, o efluente s poder ser descarregado quando se estabelecer uma comunidade biolgica balanceada entre algas e bactrias e se for assegurado um efluente de boa qualidade As lagoas devem ser utilizadas somente para atender os objetivos para os quais foram projetadas. Por exemplo: no devem ser utilizadas como rea de recreao. Por constiturem, muitas vezes, o maior espelho dgua existente na regio, comumente esejam o crescente aparecimento de pssaros das mais variadas espcies e isto podem constituir ponto de atrao para passeios. No entanto, os pssaros desempenham um papel na transmisso de bactrias patognicas se expostos a um ambiente contaminado pelas fezes humanas. E, se essas reas tornam-se freqentadas pelas pessoas, os pssaros podem transportar, mecanicamente, essas bactrias para outras colees de guas, como as represas, por exemplo, e, a partir da, afetar a sade humana. claro que essa fonte de contaminao no chega a ser preocupante, uma vez que o meio aqutico no constitui um ambiente propcio para o crescimento bacteriano. Entretanto, os pssaros podem atuar como um reservatrio de insetos (mosquitos) contaminados por arbovros e, posteriormente transmitir doenas ao homem que venha a se alimentar das aves infectadas. Outro aspecto importante de sade humana a presena de mosquito na lagoa ou em outro sistema de tratamento de esgoto, alm de provocar incomodo a vizinhana, podem ser vetores de vrias doenas, entre as quais aquelas da espcie Culex, responsveis pela filariose. Porem um sistema de lagoa de estabilizao bem projetado e mantido, sem vegetao emergente nos diques internos, inexiste as condies para a procriao desses insetos. Embora as lagoas de estabilizao em srie sejam mais eficientes que as estaes convencionais para a remoo de bactrias e vrus, existem a possibilidade de contaminao ou infeco por organismo patognico. Como medida preventiva os operadores de lagoa ou outro sistema de tratamento de esgoto, devem ser orientados para fornecer informaes ao pblico em geral, no sentido de conscientiz-los sobre esses riscos, apesar do aspecto agradvel e inofensivo que o efluente de uma associao de lagoas em srie apresenta ou de outro sistema de tratamento de esgoto. 5.1. Cuidados a Serem Tomados pelo Operador No interesse de sua sade pessoal e de sua famlia, toda equipe que opera um sistema de lagoas de estabilizao ou de outro sistema de tratamento de esgoto, deve estar consciente de que o esgoto transmite uma srie de doenas infecciosas. Para se precaver destas doenas tomarem os seguintes cuidados. Evitar qualquer contato com o esgoto; No realize qualquer trabalho, at que instrues tenham sido dadas e compreendidas. No corra na rea da estao de tratamento de esgoto, a no ser em casos de emergncia. No opere nenhum equipamento, a no ser que tenha recebido instrues.
_________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ________ _________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ _____

Srie Material de apio

Professor: Eng Osmar Mendes Ferreira, Ms

Pontifcia Universidade Catlica de Gois - Curso de Graduao Engenharia Ambiental Disciplina: Tratamento de Resduos Lquidos I e II

_________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ __ _______________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________

Guarde os equipamentos de segurana aps o uso. Mantenha os equipamentos limpos e em condies de uso. Utilize as ferramentas corretas e da forma adequada para cada servio. Use equipamento de proteo sempre que necessrio No use roupas muito largas. Mantenha as unhas cortadas e remova todo material estranho com escova, gua e sabo. Comunique e trate imediatamente todo ferimento ocorrido durante o trabalho. Usar luvas e botas em todas as tarefas, tais como limpeza do gradeamento, caixa desarenadora, caixa de gordura; No caso de contato com o esgoto, usar lcool iodatado para a limpeza do corpo; Lavar as mos antes de acender um cigarro ou comer qualquer alimento; Deixar as roupas usadas para trabalhar na estao de tratamento e nunca entrar ir para casa com essa roupa; A roupa usada dever ser desinfetada e lavada no local de trabalho e secada ao sol. O operador deve ter dois pares de roupa. Aps o uso de ferramenta (escumadeiras, ps, enxada, rodos etc.) lav-las com jato dgua; Caso ocorra algum corte nos dedos, ou arranho nos braos, limpar com gua e aplicar iodo ou merthiolate; Fazer o reforo de vacinas (Ttano, tifo e varicela) de acordo com orientaes mdicas; Manter as unhas sempre limpas e cortadas, pois unhas grandes e sujas transmitem doenas. Tenha sempre um estojo de primeiros socorros no trabalho e reponha periodicamente os materiais utilizados.

_________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ________ _________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ _____

Srie Material de apio

Professor: Eng Osmar Mendes Ferreira, Ms

Pontifcia Universidade Catlica de Gois - Curso de Graduao Engenharia Ambiental Disciplina: Tratamento de Resduos Lquidos I e II

_________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ __ _______________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________

ANEXO II 1. OPERAO DE LAGOAS DE ESTABILIZAO 1.1. Inspeo inicial do sistema de lagoas de estabilizao Numa inspeo inicial, importante observar as dimenses, unidades e detalhes do projeto, como tambm as condies e materiais necessrios ao bom andamento das atividades operacionais. Dessa forma, deve-se atentar para os seguintes aspectos a) Obedincia ao projeto: unidades previstas e suas dimenses; inclinao e proteo dos taludes; alimentao das unidades; iluminao e residncia do operador; existindo estao elevatria, checar as bombas, sensores de alimentao e comandos eltricos; condies de terreno da lagoa (se existem formigueiros, ninhos de ratos). b) Condies bsicas locais: cercamento de rea, para controlar o acesso de pessoas e veculos; passadios e guarda-corpos nas vias de acesso as caixas de sada das lagoas; instalao sanitria; pontos de gua potvel, principalmente prximo aos locais de amostragem; instrumento de limpeza (p perfurada, para remoo do material sedimentado na caixa de areia; rastelo para remoo de material gradeado; peneira de nilon, com cabo longo, para remoo de sobrenadante; carrinho de mo para transporte do material removido; mangueira; p para cobrir o material gradeado; escovo para limpar vertedores e tbuas de stop-logs etc.) e fichas de anotao rotineira. tabela de vazo referente aos medidores; curvas das bombas, caso exista estao elevatria; inexistncia de barreiras naturais ou artificiais ao dos ventos sobre a rea das lagoas; escala de operadores e/ou de servios definida; comportas de stop-logs estanques.

1.2. Procedimento para carregamento das lagoas de estabilizao A tcnica a ser adotada na partida inicial de uma lagoa de estabilizao depende das circunstncias locais. Todavia, qualquer que seja a situao, a fase de carregamento deve ocorrer de preferncia no vero, quando h predominncia de temperatura mais elevada. Dois procedimentos devem ser evitados: receber a carga de esgota prevista em projeto antes que se estabelea, na lagoa, uma comunidade balanceada de algas e bactrias. Se este procedimento for adotado, as
_________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ________ _________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ _____

Srie Material de apio

Professor: Eng Osmar Mendes Ferreira, Ms

Pontifcia Universidade Catlica de Gois - Curso de Graduao Engenharia Ambiental Disciplina: Tratamento de Resduos Lquidos I e II

_________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ __ _______________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________

lagos passaro por um processo de decomposio anaerbica, com predomnio da fermentao acida e emanao de odores insuportveis de compostos putrescveis base de enxofre e nitrognio, tais como os mercaptanas, os cidos triogliclicos e cada-verinos. Alm de serem dispendiosos as medidas necessrias para minimizar estes problemas, elas levam cerca de quase dois meses para surtirem efeitos, e sua eficcia, at certo ponto incontrolvel, depender do tamanho da lagoa e do numero de clulas do sistema: quanto maiores forem as lagoas, maior ser a possibilidade de que esses problemas se tornem incontrolveis; carregar as lagoas com pequenas e continuadas contribuies de esgotos, procedimento habitual no caso de ser baixo o numero de ligaes domiciliares. Isto porque at que ocorra a colmatao do terreno, todo liquido ou parte dele, pode percolar pelos taludes e o lastro, fazendo com que a se acumule material slido putrescvel e/ou se estabelea a anaerobiose e putrefao, com exalao de maus odores. Outro aspecto ocasionado pela demora ascensional da lmina a fermentao da lagoa e das saias dos diques internos, possibilitando o desenvolvimento de uma vegetao incontrolvel que, se no for removida, trar inconvenientes futuros operao e ao funcionamento do sistema. Assim, se o sistema situar-se prximo do corpo da gua receptor ou se dispuser de gua de abastecimento pblico, dois procedimentos so recomendados na partida inicial das lagoas: enchimento das lagoas com gua bombeada do crrego ou proveniente do sistema de abastecimento pblico. Neste caso, a gua bombeada do crrego ou proveniente da rede publica de abastecimento deve alcanar um volume tal que assegure uma lmina mnima, se possvel de 1m. Atingindo esse nvel, a introduo de esgoto pode ser iniciada, bloqueando-se evidentemente todos os dispositivos de sada (stoplog), at que se alcance a lmina prevista em projeto. Este procedimento impede o crescimento de vegetao, permite testar a estanqueidade do conjunto (lastro e taludes) e possibilita a correo de eventuais deficincias decorrentes de uma compactao insuficiente na construo das lagoas, desde que seja realizado antes que elas recebam carga de esgoto; enchimento intermitente da lagoa com uma mistura de gua bombeada do crrego e do esgoto a ser tratado. O enchimento com mistura de gua e esgoto (diluio de 5:1 ou menores) feito at se assegurar uns 0.40 m de lmina. Aguardam-se alguns dias, at que se verifique, visualmente, o surgimento das algas. A partir dessa constatao nos dias subseqentes, mais esgotos - ou mistura de gua/esgoto, sero adicionados at desenvolver-se uma florao de algas, o que requer um perodo de 7 a 14 dias de paralisao. Decorrido esse perodo, o enchimento da lagoa em esgoto realizada at o nvel de operao quando, novamente, deve ser interrompido. Ao se estabelecer no meio de uma populao de algas, o que tambm demora de 7 a 14 dias, a lagoa passa a receber os esgotos normalmente. Naturalmente, essas intermitncias, o recebimento de diluio ou de esgotos, a florao de algas para preparar um meio balanceado de algas e bactrias devem ser acompanhados, de perto, por operadores com certa vivncia prtica desses processos. Um perodo de aproximadamente 60 dias necessrio para que se estabelea uma boa comunidade biolgica (QUADRO 1). Quadro 1: Resumo das principais reaes biolgicas e exigncias ambientais numa lagoa de estabilizao de esgoto sanitrio
_________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ________ _________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ _____

Srie Material de apio

Professor: Eng Osmar Mendes Ferreira, Ms

Pontifcia Universidade Catlica de Gois - Curso de Graduao Engenharia Ambiental Disciplina: Tratamento de Resduos Lquidos I e II

10

_________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ __ _______________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________

Reao biolgica
Oxidao anaerbica Ao fotossinttica Fermentao acida Fermentao metnica

Caractersticas
Organismos Bactrias aerbias Algas Bactrias facultativas heterotrficas Bactrias produtoras de metano Alimentos bsicos Carboidratos protenas CO2 , NH3 Carboidratos protenas gorduras cidos orgnicos Principais produtos CO2 , NH3 Oxignio das algas cidos orgnicos CO2 , NH4, H2 Tempo requerido (dia)* 5 - 10 10 - 20 10 - 20 Odores produzidos Nenhum Nenhum H2 S cidos orgnicos H 2S Temp. C permissvel adequada ** 0 40 15 - 30 4 40 15 - 25 0 50 10 - 40 6 50 14 - 30

Fatores ambientais
Oxignio Necessrio Necessrio dentro de certas condies Desnecessrio dentro de certas condies Deve ser excludo pH 7,0 9,0 6,5 10,5 4,5 8,5 Luz No necessrio Necessrio No necessrio No necessrio

40 - 50

6,8 7,2

* Tempo requerido para desenvolver uma populao de organismos estveis. ** Os nmeros que se situam acima da linha dizem respeito a faixa permissvel e os nmeros abaixo da linha se referem faixa adequada Fonte: Adaptada de Oswaldo, W.J. apud Sanches, A e Vargas, C.

1.3. Incio de operao de lagoa anaerbia Iniciar a introduo dos esgotos, conforme as recomendaes feitas no item 1.2 Procedimentos para o carregamento das lagoas de estabilizao. Manter o pH do contedo lquido levemente alcalino ( 7,2 a 7,5 ). Esta tarefa pode ser facilitada se, ocorridos os primeiros 30 dias de operao, for inoculado lodo digerido de estaes ou tanques Imhoff ou se for aplicado p calcrio, cinza vegetal ou bicarbonato de sdio. 1.4. Inicio de Operao de Lagoa Facultativa. Iniciar a introduo dos esgotos, conforme as recomendaes feitas no item 1.2 Procedimento para carregamento das lagoas de estabilizao. A manuteno de pH acima de 7,5 ser assegurada, sem a adio de produtos qumicos, se forem seguidas as instrues do item 1.2. Uma comunidade biolgica balanceada entre algas e bactrias esperada 60 dias aps o incio da operao. Medir diariamente o oxignio dissolvido. 1.5. Incio de operaes de lagoa em srie a) Partida inicial da clula primria. Se a lagoa for anaerbia, seguir as instrues do item 1.3 - Incio de operao de uma lagoa anaerbia , e , se for facultativa, seguir os instrues do item 1.4 - Incio de operao de uma lagoa facultativa. b) Partida inicial das outras clulas. o enchimento com gua das lagoas secundrias, tercirias e demais de uma associao em srie pode comear quando a clula primria atingir uma lmina mnima de 1,0 m; a adio de gua do rio ou do sistema pblico de abastecimento nas demais lagoas em srie deve ser feito at que atinja um nvel de 1,0 m. Evidentemente, todos os dispositivos de sadas dessas clulas devem estar fechados; quando a clula primria atingir a lmina de operao de projeto (geralmente maior que 1,0 m), seu efluente pode ser transferido para a clula subseqente, tomando-se as seguintes precaues: retirar os stop-logs lentamente, impedindo assim, que a lmina de gua da unidade precedente caia abaixo de 1,0 m; no efetuar operaes de descarga de fundo da clula primria para que se acelere
_________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ________ _________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ _____

Srie Material de apio

Professor: Eng Osmar Mendes Ferreira, Ms

Pontifcia Universidade Catlica de Gois - Curso de Graduao Engenharia Ambiental Disciplina: Tratamento de Resduos Lquidos I e II

11

_________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ __ _______________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________

a equalizao dos nveis de gua nas demais lagoas; equalizar, dessa forma lenta, as lminas de gua em todas as lagoas; se a instalao dispuser de bomba, recircular o efluente de qualquer lagoa do sistema para aquela que necessita elevar o seu nvel de operao.

c) A simultaneidade ou no das diversas etapas dos enchimentos das lagoas ocorrer em funo: do volume de gua que pode ser retirada do rio ou do sistema pblico de abastecimento de gua sem que cause inconvenientes aos usos que deles so feitos; da diferena das presses hidrostticas exercidas pelos volumes de gua das lagoas adjacentes sobre os taludes de terra que constituem a interface entre ela. Por exemplo, se uma lagoa anaerbia de 3,0 m de profundidade for seguida de uma facultativa de 1,5 m de profundidade, cujos fundos estejam na mesma quota, no conveniente deixar a primeira clula atingir o seu nvel de operao, enquanto a segunda permanecer totalmente vazia. Caso no se adote este procedimento, haver possibilidade de rompimento ou percolao de gua atravs de divisrio das duas clulas.

2. OPERAO E MANUTENO.

2.1. Introduo Para se atender aos objetivos de um tratamento de esgoto, necessrio executar eficientemente as atividades de inspeo, operao, manuteno e avaliao de desempenho. Esta ltima visa a conhecer as condies reais de funcionamento da instalao, pois o acmulo desse conhecimento, atravs de parmetros de controle, permite: dominar a instalao de forma a tornar possvel o seu manejo tanto em condies normais quanto em situao especiais; prever os problemas que podero ocorrer. Um controle adequado do processo envolve o conhecimento da composio qualitativa e quantitativa do esgoto afluente, certo domnio dos fenmenos que ocorrem nesse ambiente, alm da caracterizao do efluente do sistema. Assim, existem trs pontos principais de controle numa lagoa de estabilizao: a lagoa em si, a sua entrada e a sua sada. As diversas anlises e medies realizadas em cada um desses pontos sero utilizadas para: determinar como est se desenvolvendo o processo de tratamento; prever as alteraes operacionais que fizeram necessrias; e verificar a eficincia do sistema. Alguma determinao pode ser efetuada diariamente pelo prprio operador que. Outras determinaes exigem tcnicas e equipamentos especficos. Amostras do afluente de cada unidade que compe um sistema devero ser coletadas periodicamente para analise, em laboratrio, dos principais parmetros que permitem avaliar o comportamento da operao do sistema de tratamento. Se a localidade dispuser de laboratrio, tcnicos de nvel mdio e engenheiro treinado, as amostragens, as determinaes laboratoriais, a orientao e fiscalizao do programa de avaliao de desempenho do sistema devero ficar a cargo do supervisor ou do responsvel pelo sistema. Quando isso no for praticvel, o responsvel pelo sistema devera solicitar a participao do rgo estadual de controle da poluio e, em colaborao com ele, executar o conjunto de tarefas que caracterizam o funcionamento e o desempenho do sistema.
_________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ________ _________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ _____

Srie Material de apio

Professor: Eng Osmar Mendes Ferreira, Ms

Pontifcia Universidade Catlica de Gois - Curso de Graduao Engenharia Ambiental Disciplina: Tratamento de Resduos Lquidos I e II

12

_________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ __ _______________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________

Os procedimentos de coleta e analise devem seguir normas e recomendao sugeridas e/ou consagradas por entidades especializadas. Existem, na maioria dos casos, diferentes mtodos que podem ser utilizados, todos validos desde que compatveis com a condio que qualidade do meio a ser amostrado e/ou analisados. Determinao de alcalinidade em guas - Mtodos da Titulao at pH prdeterminado. Demanda Bioqumica de Oxignio (DBO) - Mtodo da titulao e encubao (20C, 5 dias). Determinao de fsforo em guas - Mtodos do cidos ascrbico. Determinao de nitrognio amoniacal em guas - Mtodo de nesslerizao em destilao prvia. Determinao de nitrognio orgnico e de nitrognio total Kjeldhal em guas Mtodo da determinao de nitrognio na forma de amnia. Determinao de pH em guas. Determinao do resduo sedimentvel em gua - Mtodo do cone Imhoff. Determinao do resduo em guas - Mtodo gravimtrico. Determinao de oxignio dissolvido (OD) em gua - Mtodo de Winkler modificado pela azida sdica. Coliformes totais e fecais - Determinao do nmero mais provvel pela tcnica de tubos mltiplos - Mtodo de ensaio. Demanda Qumica de Oxignio (DQO) - Mtodo refluxo aberto. 2.2. Dimensionamento da equipe de trabalho Pessoal Necessrio O numero de pessoas necessria para realizar um controle adequado das lagoas de estabilizao depende, fundamentalmente, do porte da instalao e do numero de clulas que compem o sistema. No existe uma regra absoluta para quantificar o numero de operrios necessrios ao bom funcionamento desses sistemas. Todavia, um critrio adotado na ndia demonstrado pelo Quadro 2 - pode auxiliar o responsvel pelo sistema mensurar. Quadro 2: Dimensionamento da equipe de operao em sistemas de lagoa de operao
Pessoal Supervisor Ajudante 5.000 2 10.000 3 50.000 1 6 100.000 1 8 200.000 1 8 Fonte: Aceivala, S. J. Wastewater treatment and disposal engineering and ecology in pollution control. New York, Marcel Dekker, 1981. Populao servida por lagoa

Funes do Pessoal a) Supervisor Como encarregado das lagoas, devera possuir conhecimento sobre a operao e manuteno desses sistemas e manter-se, sempre que possvel, atualizado, participando, para isso, dos
_________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ________ _________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ _____

Srie Material de apio

Professor: Eng Osmar Mendes Ferreira, Ms

Pontifcia Universidade Catlica de Gois - Curso de Graduao Engenharia Ambiental Disciplina: Tratamento de Resduos Lquidos I e II

13

_________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ __ _______________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________

cursos ministrados por rgos estaduais de controle de poluio das guas ou pelas universidades existentes na sua regio de trabalho. Suas principais responsabilidades so: ter autoridade suficiente sobre o pessoal de manuteno, instruindo-o sobre as atividades; informar pessoalmente o responsvel pelo sistema sobre o funcionamento e o estado geral das lagoas de estabilizao; realizar os controles necessrios operao normal da instalao, que so: meteorolgico: envolvendo a leitura dos instrumentos, dos registros e sua manuteno; fsico-qumicos : evolve a leitura de parmetros e as analises de amostras; coleta de amostras para exames de ficto plncton e zo plncton; registrar os dados obtidos, processar as informao, enviando-as ao responsvel pelo sistema e , quando solicitadas, ao rgo estadual de controle da poluio. b) Ajudantes So responsvel, fundamental, pela manuteno dos taludes, limpeza das grades, caixa de desarenadora, vertedores, dispositivos de alimentao, pela sada e regulagem dos fluxos, por medir as vazes horrias e cuidar do paisagismo e urbanizao de toda rea de tratamento. 2.3. Atividades Gerais de Inspeo e Manuteno Atividades dirias do operador a) Percorrer o permetro do sistema de tratamento de esgoto, bem como o de cada lagoa, procurando verificar: se no existe nenhum mouro de cerca enfraquecida ou arame arrebentado, visando, com essa precauo, impedir a entrada de animais ou pessoas estranhas no local; o estado de conservao dos gramados de proteo dos diques internos e externos; se os avisos, indicando ser o local um sistema de tratamento de esgoto, esto fixados em pontos bem visveis; se existe algum vazamento de liquido pelos talude; o estado de conservao e de limpeza das calhas divisoras de gua pluviais; se a distribuio de vazo, no estado de existncia de entradas e sadas mltiplas, eqitativa pelos diversos ramais; se os nveis de operao esto adequados; b) Anotar os dados meteorolgico - temperatura, precipitao pluviomtrica e ventos na ficha Diria de controle operacional. c) Se existir estao meteorolgica no local, medir quantitativamente: horas de insolao, temperatura do ar (mxima, mdia e mnima), precipitao, evaporao, direo dos ventos, umidade do ar, nebulosidade. Atividade Peridica do operador a) limpar as valas de proteo contra as guas pluviais, removendo as areias nelas depositadas b) Pintar cercas e placas de avisos.
_________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ________ _________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ _____

Srie Material de apio

Professor: Eng Osmar Mendes Ferreira, Ms

Pontifcia Universidade Catlica de Gois - Curso de Graduao Engenharia Ambiental Disciplina: Tratamento de Resduos Lquidos I e II

14

_________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ __ _______________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________

2.4. Atividade Rotineira de Operao e Controle Unidades de Remoo de slidos Grosseiros A Figura 1 ilustra um conjunto de unidades de remoo de solidas grosseiro, constitudo de uma grade e uma caixa de areia de cmera dupla, seguido de um medidor de vazo tipo Parshall.

Figura 1: Tratamento preliminar

a) O material retido nas grades devera ser removido com uma freqncia de modo a evitar que o aumento da perda de carga localizada nas barras cause represamento dos esgotos no canal a montante e aumento demasiado na velocidade da liquido entre barras, arrastando alguns materiais que deveriam ser retidos nessa unidade. b) As caixas de areia so dispositivos empregados para remover material inorgnico, no putrescvel, caracterizando-se como partculas com tamanho superior a 0.2 mm que no floculam e possuem uma velocidade de sedimentao maior que a das partculas orgnicas. Atividades Dirias do Operador a) Dar pancadas, de hora em hora, na grade, com rastelo apropriado. b) Passar material gradeado pra um crivo, constitudo sobre o canal a jusante da grade, a intervalo mximo de 3 horas. Nesse local, com esguicho de mangueira, o material poder ser lavado, livrando-o de toda a sua matria orgnica no grosseira, reduzindo-se, entoa, seu volume. c) Todas as manhas, o material- j lavado e escoado - dever ser depositado em valas apropriado e recoberto com pequena camada de terra, para que seja digerido fora do acesso de inseto, especialmente das moscas; d) Agitar, trs vezes por dia, a caixa desarenadora no sentido contrrio ao fluxo dos esgotos forando, desse modo, a matria orgnica que porventura tenha se sedimentado (especialmente nas horas de menor vazo) a voltar ao meio lquido e a ser transportada at as lagoas de estabilizao, dimensionadas para receber esse tipo de slido. Atividades Peridicas do Operador

_________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ________ _________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ _____

Srie Material de apio

Professor: Eng Osmar Mendes Ferreira, Ms

Pontifcia Universidade Catlica de Gois - Curso de Graduao Engenharia Ambiental Disciplina: Tratamento de Resduos Lquidos I e II

15

_________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ __ _______________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________

Realizar a descarga ou limpeza da caixa de areia sempre que o material acumulado ocupar a metade da altura da cmara de armazenamento ou 2/3 de todo o seu comprimento. Os intervalos entre as limpezas geralmente so de 07 dias. interessante observar que: o ideal possuir duas unidades de caixa de areia, pois, dessa forma, uma pode ser isolada para limpeza enquanto a outra colocada em funcionamento; a areia, bem como o material sedimentado nessa unidade, depois de retirada por meio de ps ou enxadas deve ser transportada e, depois, convenientemente enterrada. a cmara, depois de lavada, est pronta para ser reutilizada. Unidades de Medio e Controle de Vazo Atividade Diria do Operador a) Sempre que possvel, dispor de registradores de vazo afluente ou realizar medies horrias que cubram pelo menos o perodo diurno. Quando isso for possvel, optar por leituras s 7:00 h, 9:00 h, 12:00 h, 13:00 h, 17:00 h, 18:00 h e 21:00 h. O operador deve, antes de cada leitura, limpar as calhas vertedores e/ou o canal afluente ao dispositivo de medio, impedindo qualquer interferncia no fluxo que possa prejudicar as leituras. Os valores medidos devem ser anotados na Ficha Diria de Controle Operacional; b) Quando o sistema dispuser de medidores de vazo e/ou caixas de diviso de fluxos que no pertenam ao seu esgoto afluente ou essas vazes devem ser registradas ou devem se realizadas medies horrias durante 24 horas num perodo que cubra pelo menos uma semana em diferentes meses do ano. Baseando-se na analise dessas curvas de vazo, a freqncia das leituras nesses dispositivos de controle e medio de vazo deve ser definida. Atividades Peridicas a) A distribuio e regulagem dos fluxos num sistema de lagoa uma das ferramentas mais teis de que dispe o operador para controlar os processos de tratamento. Se o sistema projetado no possui essa flexibilidade, o trabalho do operador torna-se bem mais difcil. Num sistema unicelular, nica flexibilidade de que dispe o operador o controle da profundidade da lmina de gua. Atravs das alteraes pode-se controlar a vegetao, a reduo do numero de larvas de mosquito dos diques, o ajuste dos nveis de insolao e a eficincia do processo. Quando o sistema projetado inclui mltiplas clulas em serie e/ou em paralelo, o operador possui um maior numero de opes para o controle, entre os quais; transferir liquido de uma lagoa para outra, para correo de um problema de deficincia de oxignio; variar a profundidade da lmina de gua pra controle da vegetao e das larvas de mosquito; isolar uma clula que se tornou anaerbica ou permitir que haja uma aclimatao dos microorganismo para assimilar uma carga de resduos txicos; alterar o regime de operao, em srie ou em paralelo, para re-distribuir as cargas orgnicas nas diferentes lagoas; acumular os esgotos numa clula primaria, especialmente durante as operaes de descarga sazonais freqentes em industrias. b) Limpar, periodicamente, os vertedores e encaixe das tabuas dos dispositivos de sada das lagoas com auxilio de escovo, para evitar que se formem crostas de escuma e/ou algas.
_________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ________ _________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ _____

Srie Material de apio

Professor: Eng Osmar Mendes Ferreira, Ms

Pontifcia Universidade Catlica de Gois - Curso de Graduao Engenharia Ambiental Disciplina: Tratamento de Resduos Lquidos I e II

16

_________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ __ _______________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________

c) Se existir comportadas com volante para fazer variar o nvel de gua, a haste da comporta deve estar sempre lubrificada com graxa para prevenir o aparecimento de ferrugem que dificulta o seu acionamento. Lagoas Anaerbicas Atividade diria do Operador a) Medir a temperatura do esgoto afluente, da lagoa e do efluente, o nvel da lmina lquida na lagoa, pH e slidos sedimentveis tanto no esgoto bruto quanto no efluente, pelo menos s 7:00 h, 12:00 h e 17:00 h. Anotar esse dados na ficha de controle Operacional. b) Bater, com instrumento simples (um quadrado de tbua fixado ponta de uma vara de metros de comprimento), pelo menos duas vezes ao dia, nos sobrenadantes. S se justificam essas operaes quanto se constata que so eles, na verdade, os responsveis pela exalao de maus odores. c) Retirar dos sobrenadantes as pequenas partes que ficam ao alcance - prximas das margens - e enterr-las em valas apropriadas. d) Combater qualquer inicio de eroso nos taludes. e) Manter s margens isenta de vegetais, bem como os diversos pontos da lagoa. f) No permitir a ocorrncia de processos erosivos nos taludes e, caso ocorra, obstru-los com argila. g) Manter limpos os dispositivos de entrada de esgoto na lagoa, principalmente quando so submersos. h) No caso de a lagoa anaerbica ser seguida de uma facultativa, no permitir a passagem de material flutuante para uma clula subseqente. Atividade Peridica a) Esparzir, pelo menos uma ver por semana. Cinzas vegetais sobre as crostas sobrenadantes das lagoas anaerbicas e, enquanto isso, bater as escumas com instrumento simples. b) Realizar analise para controle operacional rotineiro da lagoa. conveniente que, por ocasio da coleta de amostra sejam efetuados, em campo determinao de pH e slidos sedimentveis. A realizao dessas analise uma das atividades dirias do operador. Com exceo da colimetria e alcalinidade, as demais determinaes laboratoriais devem ser feitas a partir da coleta de amostras compostas em 24;00 horas. c) Verificar, nas estaes de inverno e vero, a provvel espessura da camada de lodo. Tal procedimento visa acompanhar o comportamento da lagoa: o acumulo e a distribuio de lodo. A possvel poca da remoo do lodo e a limpeza da unidade de tratamento. Lagoa Facultativa Atividades Dirias do Operador a) Medir a temperatura dos esgotos efluentes, da lagoa e do efluente. O nvel da lmina liquida da lagoa, o pH no afluente e no efluente da lagoa, os slidos sedimentveis no
_________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ________ _________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ _____

Srie Material de apio

Professor: Eng Osmar Mendes Ferreira, Ms

Pontifcia Universidade Catlica de Gois - Curso de Graduao Engenharia Ambiental Disciplina: Tratamento de Resduos Lquidos I e II

17

_________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ __ _______________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________

esgoto bruto e no efluente nos casos da clulas primarias, o OD (oxignio dissolvido) a 20 cm abaixo da superfcie, pelo menos s 7:00 h, 12:00 h e 17:00 h. Anotar esses dados na ficha diria de controle operacional. b) Havendo crostas de escumas nessas lagoas, devero ser jateadas com gua, destrudas com rastelo ou removidas com peneira de nilon ou estopa de cabo longo, enterrando-se posteriormente o material. c) Cuidar da conservao dos taludes e dos seus gramados, enviando e/ou corrigindo as possveis eroses. d) Caso no exista uma faixa de lajotas de concreto altura da lamina de gua, manter os taludes limpos - carpidos e roados - nos pontos de contato com o liquido, mudando a cada 15 dias, os nveis da superfcie liquida, por meio de stop-logs. e) Manter limpos os dispositivos de entrada do esgoto afluente. f) Controlar o nvel de gua de acordo com a insolao e eficincia do processo. g) Manter os poos vertedores dos efluentes isentos de qualquer material que tenha sido indevidamente nele lanado. Atividades Peridicas a) Realizar, duas vezes por semana, prximo a entrada, no meio, e prximo sada da lagoa, a uma profundidade de 20 cm abaixo da superfcie, 20 cm acima do fundo e no meio da lmina liquida, as seguintes determinaes: Oxignio de respirao; Oxignio dissolvido Oxignio fotossntese b) Realizar analise para controle operacional rotineiro da lagoa. conveniente que, por ocasio da coleta de amostras, se efetuem determinao, em campo, de pH e slidos sedimentveis tarefas estas que fazem parte das atividades dirias do operador. 2.5. Limpeza de Lagoas de Estabilizao Freqncia . Teoricamente a quantidade de lodo acumulado numa lagoa anaerbica de cerca de 0,26 L/hab. por dia e, aps secagem ao ar, de 0,13 L/hab. dia. Neste ultimo estado. Ele contm 45% de slidos de 55% de gua, ou seja, a taxa de acumulao de lodo seco de 0,03 a 0,04 m/hab. ano. Nas lagoas facultativas (bem mais raras que as anaerbicas) submetidas a intensas e variadas radiaes do sol, temperaturas acima de 15C so para as nossas condies climticas, sempre asseguradas na camada de lodo. Raramente a remoo de lodo se justifica antes de 15 anos, interruptos de funcionamento. J que, acima daquela temperatura mnima, os processos de digesto anaerbica desenvolvem favoravelmente. oportuno registrar que, em lagoas onde existem zonas mortas, pode ocorrer uma sedimentao exagerada de algas mortas (5,0 cm/ano), o que pode levar o operador menos avisado a concluir por um assoreamento prematuro da lagoa. Procedimentos de Limpezas

_________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ________ _________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ _____

Srie Material de apio

Professor: Eng Osmar Mendes Ferreira, Ms

Pontifcia Universidade Catlica de Gois - Curso de Graduao Engenharia Ambiental Disciplina: Tratamento de Resduos Lquidos I e II

18

_________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ __ _______________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________

O lodo acumulado numa lagoa de estabilizao deve ser removido quando sua espessura atingir a metade de lamina de gua de operao. Esta deve ser a seqncias dos procedimentos adotados para sua limpeza: a lagoa, cujo lodo ser removido, devera sair temporariamente do circuito, desviando-se os esgotos para uma outra clula em uso ou, em ultimo casos, para o curso de gua. Esta operao deve realizar-se de forma gradual, de modo a no prejudicar o funcionamento normal da lagoa em uso ou interferir o mnimo possvel nos diversos usos de jusante do corpo receptor; os stop-logs das caixas de sadas devem ser removidos seqencialmente, de forma gradativa, e os lquidos encaminhados para a outra clulas em uso. A lmina de gua deve ser rebaixada at que alcance a camada de lodo; o lodo, exposto ao sol, perdera paulatinamente sua gua intersticial, secando ao ar livre; quando o lodo apresentar rachaduras e torna-se manusevel com garfos de brita, devera ser retirado da lagoa e utilizada como condicionador de solo ou adubo na prpria rea da estao. Essas recomendaes sero aplicadas facilmente, se no existir interferncias das guas do lenol freticas nas lagoas de estabilizao. Na hiptese da existncia de lenol fretico aflorante realimentando as lagoas, o lodo ali acumulado dificilmente secara ao ar livre, e a remoo s ser vivel atravs de processos mecnicos. Os procedimentos recomendados, neste caso, so os seguintes: construir, previamente, prximos lagoa a ser limpa, uma pequena lagoa com fundo em cota superior ao nvel do lenol subterrneo, dotada de drenos (a 0,40 m do fundo) e tubos extravasares ( ladro); interromper, temporariamente, a alimentao dos esgotos e colocar, na lagoa a ser limpa, uma draga para retirada dos lodos; a draga, circulando ordenadamente, succionar e bombeara os lodos para a lagoa auxiliar ate o nvel mximo de extravasar, quando dever interromper, por algumas horas, o seu funcionamento. Pouco a pouco, o nvel da lagoa auxiliar ira baixando, atravs dos drenos (manilhas ou bambus); enquanto diminui o nvel do liquido na lagoa auxiliar, o nvel da lagoa principal deve ser elevado para assegurar o calado da draga. O re-enchimento da lagoa devera ser feito com gua bombeada do crrego (quando possvel e prximos) ou das outras lagoas subseqentes; estas operaes, cclicas e associadas, entre a lagoa principal e a auxiliar, sero repetidas, ate se ter certeza de que todo o lodo foi removido da lagoa principal; o lodo acumulado na lagoa auxiliar perdera sua gua intersticial e secara ao ar livre.

3. PRINCIPAIS PROBLEMAS DE FUNCIONAMENTO E POSSVEIS SOLUES Por se tratar de um sistema de tratamento bastante simples, a maioria das lagoas de estabilizao no devidamente cuidada. A falta de interesse em seu controle operacional e o total descaso na sua manuteno leva essas lagoas, em pouco tempo, a uma situao de abandono.

_________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ________ _________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ _____

Srie Material de apio

Professor: Eng Osmar Mendes Ferreira, Ms

Pontifcia Universidade Catlica de Gois - Curso de Graduao Engenharia Ambiental Disciplina: Tratamento de Resduos Lquidos I e II

19

_________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ __ _______________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________

Quando bem projetada, bem construda, bem-operada e cuidadosamente mantida, a lagoa de estabilizao constitui um dos processos mais simples de tratamento de esgoto, no causando perturbaes vizinhana nem provocando decepes aos visitantes. Todavia, como se trata de um processo de tratamento natural, muito influenciado pelas mudanas climticas locaisno controlveis pelo homem, e recomendvel que as lagoas de estabilizao mantenham certa distancia das reas residenciais. Tratando- se de lagoas facultativas, deve-se manter um afastamento mnimo de 500m; no caso de certas lagoas anaerbicas, sempre conveniente uma distancia de 1000m ou mais. Esses nmeros, embora no constituem uma regra rgida, s deve ser desobedecida se a instalao for dotada de algum sistema de recirculao que pode ser acionado para eliminar e/ou minimizar os odores que alguma clula, temporariamente, em virtude de distrbio ou desequilbrio venha exalar. 3.1. Unidades de remoo de slidos grosseiros As maiorias das perturbaes na operao das caixas desarenadoras provem da variao da velocidade dentro da cmara, se agravando mais ainda quando a esta variao associa perfis e medidores de vazo inadequada. Excesso de Matria Orgnica no Material Removido dos Depsitos de Areia. Causas: velocidade de escoamento demasiadamente baixa; tempo de reteno demasiadamente longo. Como corrigir: reduzir a rea de seo transversal do canal da caixa de areia, adicionando-se material ao longo das paredes do canal (enchimento com tijolos rejuntados com cimento e areia, massa etc.); diminuir o numero de cmaras usadas; reajustar, quando for possvel, o vertedor de sada de maneira a diminuir a profundidade da lamina de gua, durante o perodo de vazes normais; reduzir, quando for praticvel, o comprimento da cmara por meio de deslocamento do vertedor de sada; resolver, trs vezes ao dia, o material acumulado nos depsitos das caixas de areia, no sentido contrario ao fluxo, de maneira que a matria orgnica absorvida pelo grnulo de areia possa ser liberada e siga uma trajetria normal. Arraste de Areia no Efluente das Caixas de Desarenao Causas: velocidade dos fluxos demasiadamente alta; tempo de deteno, na cmara, demasiadamente curto. Como corrigir: remover, com maior freqncia, a areia acumulada nos depsitos da caixa de desareao; colocar em funcionamento duas unidades de desareao;
_________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ________ _________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ _____

Srie Material de apio

Professor: Eng Osmar Mendes Ferreira, Ms

Pontifcia Universidade Catlica de Gois - Curso de Graduao Engenharia Ambiental Disciplina: Tratamento de Resduos Lquidos I e II

20

_________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ __ _______________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________

ampliar a rea da seo transversal das caixas de areia. 3.2. Lagoas anaerbicas Os principais problemas operacionais que ocorre numa lagoa anaerbica so os seguintes: emanao de maus odores: crescimento de vegetao aqutica nos diques internos: formao de escumas; proliferao de insetos. Maus Odores quase inevitvel que, algumas vezes, desprendem odores desagradveis de uma estao de tratamento de esgoto, no importando qual o processo empregado. A maioria dos odores e ocasionado por uma sobrecarga de matria orgnica ou pela operao inadequada do processo. As lagoas anaerbicas emitem sempre um odor caracterstico nas vizinhanas do dispositivo de alimentao e na sada. Por isso, tornam-se incmodas populao que reside em locais prximos a essas unidades de tratamento. Os odores esto associados formao de compostos de sulfetos a baixas temperaturas (abaixo de 20C) As principais causas desse inconveniente so: procedimento incorreto na partida inicial da lagoa; projetos das lagoas com cargas orgnicas volumtricas acima do permissveis ou com emprego de tempo de deteno muito reduzido; tratamento de despejo com alta concentrao de sulfeto ou com a presena de substncia txica que inibe a fermentao metnica; queda repentina ou persistncia de baixas temperaturas no contedo liquida das lagoas; admisso de despejos lquidos industriais que tendem a diminuir o pH dos esgotos baixos de 6,5. Para cada uma dessas causas so apontadas medidas corretivas abaixo especificadas. Levando-se em conta, contudo, que tanto o efeito desejados com a adoo dessas medidas leva um certo tempo para ser alcanando como tambm o fato dessas lagoas provocarem normalmente esses cheiros desagradveis, aconselha-se o plantio de fileiras de eucalipto da espcie Citrodora, circundando o conjunto depurador. Essas fileiras devem possuir cada uma, trs a dez arvores de coroa. No caso de lagoa anaerbica, a primeira fileira deve ficar a uma distancia de aproximadamente 10,00 m ou mais dos taludes, para que no sombreiem o espelho liquido. O espaamento entre as arvores de uma mesma fileira bem como a distancias das fileiras entre si pode ser de 3 a 5m. Causa a: operao inicial das lagoas. Como corrigir: Sempre que possvel, para que seja assegurada uma populao de bactrias metognicas em quantidades suficientes e evitada a acumulao dos cidos orgnicos (volteis) da primeira fase de fermentao, devem ser adotadas, no carregamento inicial da lagoa, os seguintes procedimentos: iniciar a operao das lagoas na estao de vero ou nas pocas em que as temperaturas medias do ambiente so superiores a 20C;
_________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ________ _________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ _____

Srie Material de apio

Professor: Eng Osmar Mendes Ferreira, Ms

Pontifcia Universidade Catlica de Gois - Curso de Graduao Engenharia Ambiental Disciplina: Tratamento de Resduos Lquidos I e II

21

_________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ __ _______________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________

introduzir lodo digerido de uma ETE, tanque Imnoff ou de fossas spticas inodoras, lanando-o na zona bentnica das lagoas e nas regies circunvizinhas aos tubos que a alimentaram; carregar a lagoa de maneira progressiva, evitando o lanamento brusco de toda carga orgnica; ajustar o pH do contedo liquido, com o emprego de clcio em p, bicarbonato de sdio, at que se obtenha uma neutralizao; essas operaes s devem iniciar-se quando a lagoa adquirir lamina suficientemente para que a camada bentnica do lodo inoculado no seja diretamente afetada, Esses compostos contm oxignio em sua composio, sendo este elemento bastante txico s bactrias metanognicas. Causa b: cargas orgnicas elevadas ou utilizao de reduzido tempo de deteno. Embora no se ignore que o emprego de carga orgnica elevada (at 0,20 Kg DBO/dia m) ou de deteno mnima de um ou dois dias no compromete a eficincia de remoo de DBO, quando prevalece temperaturas elevadas na massa liquida, a exalao de maus odores inevitvel, chegando a ser insuportvel. Mas, desde que exista uma distancia entre as habitaes e o sistema, nas faixas preconizadas pelo presente manual, o desprendimento de odores s incomoda aqueles que convivem diretamente com o sistema. Apesar do critrio mais indicado para dimensionar essas lagoas ser a adoo de cargas orgnicas volumtricas e no superficiais, a experincia tem confirmado que, quando a taxa de aplicao superficial supera os 1.500 Kg DBO/h por dia, a emisso de odores comea a gerar incmodos aos visitantes e principalmente a populao que, inadvertidamente, habita prximo a essas instalaes. Nesses casos, as causas de maus odores provm: da utilizao de cargas propositais no projeto, com finalidade principal de reduzida as reas de espelho de gua. Nestes casos, a instalao j parte com pouca chance de que no ocorra desprendimento de maus odores. da sobrecarga das lagoas em decorrncia de elas terem alcanadas a sua vida til, isto , de ter o sistema atingido o limite de sua capacidade de tratamento tornandose necessrio sua ampliaes. Como corrigir: ampliar o sistema de maneira que as cargas orgnicas sejam distribudas, reduzindoas, conseqentemente, a nveis tolerveis; no projetar lagoas com cargas volumtricas elevadas sem a previa avaliao do comportamento das unidades experimentais, trabalhando-se dentro das condies previstas no projeto e em idnticas condies climticas. O mau funcionamento decorrente de falhas de projeto dificilmente pode ser reparado e a comunidade, afetada pelos incmodos que o mau funcionamento acarreta, provavelmente no aceitara a lagoa de estabilizao como um processo de tratamento. Do ponto de vista operacional, entretanto, algumas medidas pode ser adotadas para controlar ou atenuar a emisso de maus odores: recircular parte do efluente de uma lagoa facultativa para a entrada da anaerbica.Razes de uma para quarto (um volume de efluente para quatro volumes de gua residurias bruta) e at de uma parte para duas podem ser utilizadas para que os problemas sejam atenuados; introduzir vegetais em decomposio (folhas e galhos midos e/ou apodrecidos); aplicar p calcrio ou cal para elevar o pH do liquido a valores levemente alcalinos (7.0 a 7.5);
_________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ________ _________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ _____

Srie Material de apio

Professor: Eng Osmar Mendes Ferreira, Ms

Pontifcia Universidade Catlica de Gois - Curso de Graduao Engenharia Ambiental Disciplina: Tratamento de Resduos Lquidos I e II

22

_________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ __ _______________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________

adicionar pores de nitrato de sdio (salitre do Chile) em vrios pontos da lagoa mantendo-a numa fase alcalina. Em solues, dosagens de at 60 mg/L podem ser necessrios; -espargir cinza vegetal, em vrios pontos da lagoa, at que ocorra a neutralizao do contedo liquido. Nota: A adio de cloro deve ser evitada, uma vez que, embora provoque rapidamente o desaparecimento de maus odores, ele acarreta problemas quando do reincio das atividades biolgicas necessrias ao tratamento. Causa c: presena de substncia txica. A exalao de maus odores, tanto nas lagoas anaerbicas quanto nos digestores anaerbicos das estaes convencionais de tratamento, pode tambm ser proveniente da presena de sulfatos e metais pesados, compostos esses que inibem as bactrias metanognicas da digesto. Como perceber: os metais pesados, os praguicidas, os resduos de fabrica de antibiticos e de industrias diversas, quando lanados nas redes municipais sem a previa autorizao dos rgos estaduais de controle de poluio, devero ser controlados na fonte, isto , na prpria industrias. Assim sendo, o operador dever notificar o rgo estadual de controle de poluio sobre o problema. Causa d: quedas bruscas e persistncia de baixas temperaturas. Sabe-se que a atividade biolgica da camada de lodo das lagoas anaerbicas e facultativas depende, principalmente, da temperatura ali predominante. Quando esta cai abaixo dos 17C, a produo de metano e significativamente reduzida e praticamente o lodo se acumula sem passar por um processo de decomposio. E a eficincia da lagoa depende, quase que exclusivamente, da decantao de slidos. No inverno, quando a fermentao processa lentamente muito provvel que se forme placas de lodo flutuante na superfcie da lagoa e, como conseqncia, esta apresentem maus odores devido produo de gs sulfdrico. Profundidades pequenas podem. Tanto no vero quanto no inverno, levar formao de escumas na superfcie, onde as bolhas de gases arrastam consigo placas de lodo da zona bentnica. Durante os meses mais quentes, quando o liquido se aquece, a camada bentnica do lodo se encontra em pela atividade biolgica e produzida uma grande quantidade de gases tpicos da fermentao metnica, os odores devem ser mnimos, principalmente, em lagoas com profundidades (acima dos 3m) Como corrigir: No existem maneiras praticas e econmicas para controlar este fator ambiental e manter a temperatura da camada de lodo acima dos 20C. interessante observar que, quando a lagoa recebe tambm guas residurias de matadouros e frigorficos (geralmente com temperaturas entre 27 - 30C), devidamente prevista no projeto,
_________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ________ _________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ _____

Srie Material de apio

Professor: Eng Osmar Mendes Ferreira, Ms

Pontifcia Universidade Catlica de Gois - Curso de Graduao Engenharia Ambiental Disciplina: Tratamento de Resduos Lquidos I e II

23

_________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ __ _______________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________

uma boa digesto pode ocorrer e, conseqentemente, ser eliminado o problema da baixa temperatura. Normalmente, com a presena desses despejos, acumula-se na superfcie da lagoa uma cobertura de material graxo que se solidifica. Esta cobertura proporciona o isolamento da lagoa, evita o resfriamento do liquido, previne a mistura da superfcie pela ao dos ventos, mantendo as condies anaerbicas do fundo, e suprime a emisso de odores incmodos. Causa e: predominncia de baixos valores de pH nos esgotos afluentes. A principal causa relaciona com a presena de certos despejos industriais, entre os quais se destacam aqueles provenientes das industrias de laticnio. Como corrigir: Adicionar, em carter temporrio ou definitivo, um substancia alcalina, de maneira a elevar o pH dos esgotos a serem tratados. necessrio, contudo, ter sempre em mente que a neutralizao do pH no necessariamente, um remdio universal para todos os desequilbrios dos processos anaerbicos de digesto. Assim, ao se dispor de um laboratrio bem equipado deve-se, sempre que possvel, medir a acidez voltil total (como acido actico) e alcalinidade total (como carbonato de sdio) de lodo em digesto. desejvel que a relao entre acidez voltil total e alcalina total seja inferior a 0,1. A elevao desse valor sinal de distrbio iminente no processo de digesto, o que pode determinar uma diminuio ou suspenso da alimentao da unidade por vrios dias. Vegetao Quando se fala de problemas oriundos do crescimento de vegetais em lagoas, dois tipos de vegetais devem ser diferentes: as ervas aquticas daninhas e os vegetais terrestre. As ervas daninhas aquticas, que constituem as pragas aquticas, acumulam-se nos taludes internos e lastros das lagoas. J os vegetai s terrestres, arbustos, ervas e capins, crescem exatamente nas lagoaqs e seus arredores. Os vegetais aquticos, ou ervas daninhas esto sempre associados a um ciclo de problema, ou seja: vegetais insetos e larvas sapos roedores cobras. O controle desses vegetais e sua remoo peridica so indispensveis para que se evite a proliferao de mosquitos e at que se garanta a segurana dos diques internos. Causas: operao inicial inadequada das lagoas; falta de conservao e manuteno diques internos. Como corrigir: para as lagoas cuja operaes inicial de carregando foi negligenciada e, em conseqncia, a vegetao proliferou de forma exuberante, propiciando um criadouro de mosquito, deve-se baixar o nvel de gua ou esvaziar-se por completo a lagoa, para que esses vegetais possam ser arrancados pela raiz; as plantas aquticas como aguaps devem ser retiradas com auxilio de barcos, cordas ou dragas; os vegetais que surgem nos taludes internos, na altura do nvel da gua, devem ser removidos pela raiz to logo ocorra o seu desaparecimento. Este trabalho precisa ser
_________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ________ _________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ _____

Srie Material de apio

Professor: Eng Osmar Mendes Ferreira, Ms

Pontifcia Universidade Catlica de Gois - Curso de Graduao Engenharia Ambiental Disciplina: Tratamento de Resduos Lquidos I e II

24

_________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ __ _______________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________

repetido varias vezes a fim de se evitar procriao de mosquitos que esses vegetais sirvam de deposito para escumas superficiais. A tcnica mais recomendada para se prevenir a criao de ervas daninhas ao nvel da lmina de gua, bem como a eroso das margens em virtude das ondas, a colocao das lajotas de concreto numa faixa de variao do nvel da gua em todo o permetro da lagoa. E, para se eliminar os vegetais terrestres que surgem acima das placas de proteo contra eroso, pode-se aplicar algum herbicida, desde que aprovado pelos rgos estaduais de controle de poluio ou sob orientao tcnica de algum rgo do ministrio da agricultura Uma prtica recomendada a aplicao de sdio na proporo de 20 mg/m da rea a ser destruda. Mosquito e Moscas A proliferao desses insetos pode ocorrer nas seguintes condies: quando existe material gradeado ou areia removida enterrados de forma inconveniente, ou exposto ao ar livre, em algum lugar prximo das lagoas; quando existe vegetao ou escuma na faixa em que o nvel de gua esta em contado com o talude. Os ovos depositados por esse insetos so muitos frgeis e no resistem ao superficial dos ventos e das correntes. Por esta razo no chegam a constituir problemas, desde que as bordas e a lagoa sejam mantidas livres de vegetao e que as escumas sejam controladas. Como corrigir: o material removido da grade e da caixa deve ser enterrado em valas previamente aberta. Para maior segurana, pode-se jogar querosene sobre o material gradeado e, a seguir, com muito cuidado, atear fogo. Logo em seguida, as cinzas devem ser cobertas com terra; o controle de vegetais deve ser feito de acordo com as instrues do item anterior desse capitulo, intitulado Vegetao. Contudo nas fases de projeto e construo, podem ser adotadas algumas medidas que reduzem, ao mximo, a proliferao de mosquitos, como: projetar os dispositivos de sada como condio que permitam regular o nvel de gua ou esvaziar, por completo, a lagoa; nivelar o fundo e eliminar toda a vegetao existente; manter em bom estado os taludes dos diques; a proliferao de moscas sobre as escumas pode ser combatida com a aplicao de alguns pesticidas ou inseticidas, em quantidade adequada de modo a no prejudicar o funcionamento normal da lagoa e nem contraria os regulamentos de proteo ambiental. Para definio do produto e sua aplicao, convm consultar, previamente, os rgos do Ministrio da Agricultura. Outro procedimento que pode ser adotado o revolvimento da camada de escuma com o auxilio de um rastelo ou o jateamento da camada de material flutuante. Essas prticas, contudo precisam ser mais bem investigadas e avaliadas quanto a suas vantagens e desvantagens. Sabe-se que a retirada das natas e escumam superficiais e mais adequadas no controle das larvas de Psychoda e da mosca domestica, pelo fato de no serem insetos aquticos. Animais Roedores

_________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ________ _________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ _____

Srie Material de apio

Professor: Eng Osmar Mendes Ferreira, Ms

Pontifcia Universidade Catlica de Gois - Curso de Graduao Engenharia Ambiental Disciplina: Tratamento de Resduos Lquidos I e II

25

_________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ __ _______________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________

Embora seja rara a presena de ratos nas lagos de estabilizao, ela pode ocorrer em algumas situaes: quando nas proximidades das lagoas existem lixes ou aterros sanitrios construdos inadequadamente; quando ocorre adensamento populacional significativo nas circunvizinhanas das lagoas e a coleta de lixo domiciliar no se processa com a necessria freqncia, obrigando os moradores a desfaze-se dele, de forma inadequada, nos fundos dos quintais, em monturos eu em lotes desabitados; quando os diques das lagoas encontram-se desprotegidos das placas de concreto (faixa de proteo no nvel da gua), mal conservados ou mal compactados durante a construo. Os ratos de esgoto ou de banhados formam, nos taludes internos das lagoas, verdadeiros tneis submersos que chegam, com o tempo, a comprometer a estabilidade dos diques. E, no caso de elevar-se o nvel de gua a lagoa, os ratos tendem a formar novos tneis mais acima da gua. Essas escavaes so facilmente perceptveis Como corrigir: evitar a construo de lagoas nas proximidades de lixes que constituem as possveis fontes de alimento desses roedores; informar o departamento de limpeza publica local para que tome a providencia, quando. Em virtude de adensamento populacional, tanto a coleta de lixo, quanto o destino que lhe vm sendo dado so inadequados; Elevar e abaixar o nvel de gua da lagoa de 15 cm a 20 cm, deixando-o permanecer por varias semanas em cada uma dessas profundidades. Como os ratos de esgotos preferem tneis parcialmente submersos, a inundao temporria e o seu ressecamento possibilitam que abandonem esses esconderijos; se o problema persistir, consultar os rgos locais de sade para que orientem sobre outros sistemas da remoo, tais como armadilha, raticidas etc. 3.3. Lagoas Facultativas Escumas A superfcie liquida de uma lagoa de estabilizao facultativa deve ser isenta de escumas, leos, graxas ou de qualquer outro material que impea a livre passagem dos raios luminosos atravs da massa liquida, prejudiquem a ao dos ventos, possa provocar maus odores ou se tornar um habitat favorvel para a proliferao de insetos. Causas: flotao de placas de lodos que se desprendem do fundo, especialmente em lagoas muito rasas e nos meses de vero, quando predominam as temperaturas elevadas; admisso de esgotos com elevadas quantidades de leos e graxas; florao de algas, chegando a formar uma nata esverdeada sobre a superfcie liquida, a qual se desloca para os cantos das lagoas pela ao dos ventos. Essa nata dificulta a passagem da luz e, se no for destruda, possibilita o surgimento de maus odores na lagoa em virtude de sua morte.
_________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ________ _________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ _____

Srie Material de apio

Professor: Eng Osmar Mendes Ferreira, Ms

Pontifcia Universidade Catlica de Gois - Curso de Graduao Engenharia Ambiental Disciplina: Tratamento de Resduos Lquidos I e II

26

_________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ __ _______________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________

Como corrigir: desagregar os flocos de lodo e quebrar as escumas com jatos de guas, rastelos ou barcos a motor; remover as escumas sempre que possvel, utilizando-se, para tanto, de uma peneira de pano presa em um cabo comprido de madeira. A escuma, coletada deve ser enterrada em valas previamente abertas no solo ou nele dispostas, para que seja posteriormente incinerada; tratando de lagoa facultativa secundria, colocar anteparos nas caixas de sadas da lagoa primria de modo a impedir a passagem de matrias flutuantes. Maus Odores Os odores so geralmente incmodos ao publico. Sua emisso tem como causas: sobrecarga orgnica; longos perodos com tempo nublado e baixas temperaturas; presena de substncias txicas nos esgotos; formao de curtos-circuitos e zonas mortas nas lagoas; e presena de massas flutuantes de algas na superfcie liquida. E ainda, acerca desta questo, levar em conta os comentrios feitos no item lagoas Anaerbicas. Causas a: sobrecarga orgnica. A sobrecarga orgnica de esgoto numa lagoa de estabilizao facultativa esta sempre acompanhada de um abaixamento de pH, queda do nvel de oxignio, mudana na cor do efluente de verde-escuro para verde - amarelado, aparecimento de manchas acinzentadas junto alimentao do efluente e, concomitantemente, de odores incmodos. Como corrigir: no caso de existirem duas clulas facultativas, aquele que apresenta o problema dever se retirar de operao at que se recupere e, enquanto isso no ocorre, devese colocar em operao a segunda clula, com a alimentao em paralelo, o carregamento pode ser reduzido; caso exista uma nica clula, poder-se , atravs de bombas e mangotes, recircular o efluente da lagoa para seu prprio afluente, de modo adicionar oxignio dissolvido e melhor distribuir a concentrao de slidos. Razes de circulao de um para quatro ou de um para seis so normalmente empregadas; havendo disponibilidade de aeradores superficiais suficientes, estes podero ser instalados temporariamente para melhorar a mistura e a oxigenao; no caso de haver uma nica entrada, o fluxo dever ser distribudo atravs de mltiplas entradas, evitando-se os problemas de curto-circuito ou caminhos preferenciais do fluxo devera ser distribudo atravs de mltiplas entradas, evitandose os problemas de curto-circuito ou caminhos preferenciais do fluxo dentro da lagoa; Causa b: longos perodos com temperatura baixa e tempo nublado. Nessa situao, a produo de oxignio ser bastante afetada chegando a ter OD igual a zero, mesmo nos perodos diurno. Como corrigir:
_________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ________ _________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ _____

Srie Material de apio

Professor: Eng Osmar Mendes Ferreira, Ms

Pontifcia Universidade Catlica de Gois - Curso de Graduao Engenharia Ambiental Disciplina: Tratamento de Resduos Lquidos I e II

27

_________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ __ _______________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________

havendo disponibilidade, instalar aeradores superficiais junto entrada do afluente, de maneira a completar, com a aerao mecnica, a produo de oxignio realizada pelas algas; recircular o efluente, utilizando bombas portteis, para a entrada da lagoa. Causa c: presena de substncia txica nos esgotos. Quando acontecem repentinas condies anaerbias numa lagoa facultativa que se encontra em operao normal, o operador deve, imediatamente, solicitar ao laboratrio central de sua companhia a realizao de uma analise fsico-qumica completa do afluente. Os resultados dessas anlises podero indicar altos teores de substncia txicas, provenientes de lanamentos de resduos industriais. Como proceder: percorrer o emissrio e a rede local junto s industrias que se localizam na bacia contribuinte, verificando , atravs de analises fsico-qumicas, a composio desses esgotos industriais. Sendo comprovada concentrao de substncia txica acima dos limites permissveis, dever ser acionada a rea competente dentro da companhia para que ela tome as providncias cabveis dentro da legislao vigente. Causa d: formao de correntes preferenciais provocando curtos-circuitos. A ocorrncia de curtos-circuitos pode ser indicada por problemas de odores, baixas concentrao de oxignio dissolvido em partes da lagoa, condies anaerbias e baixo pH. Esta indicao pode ser verificada pela determinao do oxignio dissolvido em vrios pontos da lagoa. Se detectar a ocorrncia de diferena de 100% a 20% nos valores de OD bastante provvel que no esteja havendo uma boa distribuio de esgotos na lagoa. Pois as reas que no esto recebendo boa circulao caracterizam-se por baixos valores de OD e pH. Estas podem ser causas dos curtos-circuitos: presena de vegetais aquticas no interior da lagoa; m distribuio do efluente em relao forma geomtrica da lagoa; rvores ou cercas que impeam a ao dos ventos; e irregularidades no fundo da lagoa Como corrigir: quando aos vegetais aquticos, cort-lo e remov-los. O ideal, porm, iniciar a operao da lagoa de maneira eficiente. em caso de existirem entradas mltiplas de afluentes, regularizar, uniformemente, sua distribuio; em caso de existir uma nica entrada de esgotos, efetuar uma pequena obra de reparos para ampliar o seu nmero, procurando igualar as vazes em cada uma delas; em caso de existir entradas de esgotos atravs de titulao que avana lagoa adentro, cortar e retirar a maior extenso dos tubos alimentadores, deixando suas extremidades com apenas um ou dois metros alm da saia interior dos tubos; guardar distncia de 20 m entre as margens e as rvores e cercas que circundam as lagoas;
_________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ________ _________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ _____

Srie Material de apio

Professor: Eng Osmar Mendes Ferreira, Ms

Pontifcia Universidade Catlica de Gois - Curso de Graduao Engenharia Ambiental Disciplina: Tratamento de Resduos Lquidos I e II

28

_________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ __ _______________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________

regularizar o fundo a lagoa. Causa e: presena de massa flutuante de algas na superfcie liquida. Em relao a essa questo, ver o item deste captulo intitulado Escumas. Vegetao A presena de vegetao no meio liquido da lagoa pode prejudicar a passagem dos raios luminosos, a ao dos ventos, causar problemas de curto-circuito e compor verdadeiros habitats de insetos. Mas ainda: a vegetao que aparecer nos taludes, altura da linha de gua, pode constituir no s habitats de insetos como tambm de roedores. Alm disso, a vegetao terrestre de grande porte pode trazer problemas de diminuio de isolao e da ao dos ventos. Causas: incio de operao inadequada; falta de manuteno das bordas e diques internos das lagoas; utilizao de lmina liquida abaixo de 0,90m. Como corrigir: A esse respeito as consideraes feitas neste capitulo no item Vegetao. Presena de larvas de insetos na lagoa e na rea que a circunda. Causas: material gradeado ou areia removida no-enterrada convenientemente; presena de escumas; presena de vegetao. Como corrigir: enterrar o material removido das grades e caixas de areia em valas previamente abertas. Se quiser, pode-se lanar querosene sobre o material gradeado, atear fogo e, logo em seguida, cobri-los som terra, nivelando-se o terreno; quando presena de escumas, valem os comentrios feitos acima deste Capitulo, no item intitulado Escuma; quanto a vegetao, valem os comentrios feitos no item anterior rebaixando-se o nvel de gua da lagoa, as larvas que se encontram presas aos vegetais junto aos taludes desapareceram quando esta rea secar. A oscilao alternar e peridica do nvel de gua da lagoa e uma operao que diminui o aparecimento de larvas de diversos insetos, como por exemplo: mosquito Anafheles (vetor da malaria) e o Culex (vetor da filariose). O primeiro so menos comuns nas lagoas de estabilizao; em caso de grandes quantidades de moscas, podero ser aplicados produtos qumicos nos taludes internos, nas concentraes especificas pelos fabricantes. A destruio e coleta de escumas tambm previnem o aparecimento de moscas; dependendo da concentrao de oxignio dissolvido presente na massa liquida, a ploriferao de inseto pode ser tambm combatida mediante a colocao de peixes nas lagoas de estabilizao (carpas, tilapias e gambsia). Como nas horas noturnas a concentrao de oxignio dissolvido tende a valores nulos, no possibilitando, portanto, a criao de peixes, faz-se necessrio um sistema de recirculao com gua
_________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ________ _________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ _____

Srie Material de apio

Professor: Eng Osmar Mendes Ferreira, Ms

Pontifcia Universidade Catlica de Gois - Curso de Graduao Engenharia Ambiental Disciplina: Tratamento de Resduos Lquidos I e II

29

_________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ __ _______________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________

limpa, atravs de chuveiros dispostos o mais alto possvel em relao ao espelho liquido da lagoa. Para impedir a evaso de peixe da lagoa, os dispositivos de sada do efluente devero ser antecedidos por telas ou peneiras finas de nilon que circundem os vertedores. Algas Azuis A florao de algas azuis geralmente vem acompanhando de baixos valores de pH (<6,5) e OD abaixo de 1,0 mg/L. Quando elas morrem, h emisso de odores desagradvel. Causa: tratamento incompleto; sobrecarga de esgoto; balano inadequado de nutrientes Como corrigir: fazer trs aplicaes de soluo de sulfato de cobre. Se a alcalinidade total for superior a 50 mg/l, aplicar 1g de sulfato de cobre por metro cbico de gua na lagoa; se a alcalinidade total for inferior a 50mg/L, reduzida para 0,5g de sulfato de cobre por metro cbico; destruir as natas de algas com emprego de barco, cujo motor deve ser refrigerado a ar para se evitar seu entupimento pelas algas, ou de bomba porttil e esguicho de gua sob presso. Algas Filamentosas Essas algas- que aparecem em lagoas com cargas orgnicas - limitam a penetrao da radiao solar no liquido e podem entupir as tubulaes de sada da lagoa. Causas: superdimensionamento da lagoa vazes baixas em certas estaes do ano. Como corrigir: reduzir o numero de clulas em uso aumentado dessa maneira a carga orgnica aplicada; a disperso das natas, por jateamento de gua, e sua distribuio, por meios mecnicos, no constituem recursos eficientes. Algas no Efluente A maior parte dos slidos suspensos no efluente decorre da presena de algas. Como estas, em sua maioria so unicelulares e imveis, tornam-se muito difcil a sua remoo. Causas: condies de temperatura e clima favorvel a seu crescimento. Como corrigir: retirar o efluente a partir de 0,20m abaixo da superfcie liquida e instalar uma cortina retentora de sobrenadante acoplada aos dispositivos de sada da lagoa; empregar lagoas mltiplas em series ou acrescentar unidades adicionais de
_________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ________ _________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ _____

Srie Material de apio

Professor: Eng Osmar Mendes Ferreira, Ms

Pontifcia Universidade Catlica de Gois - Curso de Graduao Engenharia Ambiental Disciplina: Tratamento de Resduos Lquidos I e II

30

_________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ __ _______________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________

tratamento, tais com filtros intermitentes de areia. Declnio do pH Do pH do meio dependem o crescimento e desenvolvimento de diversos tipos de algas. As algas verdes, por exemplo, necessitam de pH entre 8,0 e 8,4. A predominncia de seus menores valores ao nascer do sol e dos mais elevados no perodo da tarde. Causas O declnio do pH, que seguido de uma queda no OD, provoca a morte das algas verdes. Isto muitas vezes causada por: sobrecarga; longos perodos com condies meteorolgica adversas; Presena de animais tais como Daphnia , que se alimentam de algas. Como corrigir desativar temporariamente a clula e deix-la restabelecer-se; colocar em operao outra lagoa em paralelo; recircular o efluente da lagoa; verificar os possveis curtos-circuitos; no caso de sobrecarga, instalar aeradores artificiais; verificar possveis causas de toxicidade ou mortandade de algas e corrigi-las na prpria fonte. Observa-se que os procedimentos so quase idnticos aos itens Emisso de maus odores, o que demonstra a interao complexas existentes entre os sintomas de uma sobrecarga e a tendncia a decrescer os valores de pH do contedo liquido das lagoas.

_________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ________ _________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ _____

Srie Material de apio

Professor: Eng Osmar Mendes Ferreira, Ms

Pontifcia Universidade Catlica de Gois - Curso de Graduao Engenharia Ambiental Disciplina: Tratamento de Resduos Lquidos I e II

31

_________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ __ _______________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________

ANEXO III LODOS ATIVADOS 1. Comentrios iniciais Aps a concluso das obras e servios relativos implantao de todas as unidades constituintes do projeto, dever ser realizado teste de funcionamento, onde todas as unidades do tratamento fsico e biolgico devero ser preenchidas com gua limpa, verificando-se nesta oportunidade, todo fluxo hidrulico e sua estanqueidade, bem como o funcionamento dos equipamentos eletromecnicos. Uma limpeza geral diria nas instalaes do sistema de tratamento das guas residurias importante, pois permite no s tornar o local de trabalho do operador mais agradvel, como tambm necessrio para o seu bom funcionamento. Esta limpeza inclui ainda remoo de areia, dos detritos retidos no gradeamento, lavagem das calhas e paredes do decantador, bem como a remoo de graxa e escuma da sua superfcie. O operador dever periodicamente enterrar a areia removida e o material do gradeamento. Em todo processo, indispensvel a manuteno da higiene e limpeza em toda rea da estao de tratamento dos esgotos. Sempre que possvel renovar a pintura dando ateno especial nas partes metlicas, que esto mais sujeitas ao desgaste, Estes cuidados, causam boas impresses aos visitantes e torna o ambiente de trabalho agradvel e mais seguro. 2. Manuteno do Equipamento de fundamental importncia a manuteno dos equipamentos. O operador deve verificar o funcionamento de cada pea dos equipamentos diariamente. As obstrues de bombas, vlvulas de reteno e tubulaes devem ser imediatamente removidas. As peas defeituosas devem ser consertadas ou substitudas, para que tal defeito no produza reflexos negativos em outras peas do equipamento. Neste ponto bom lembrar que cuidados especiais devero ser dirigidos aos aeradores, pois so a parte central e mais importante do sistema, e o equipamento que apresentam mais defeitos. A observao de rudos, identificando problemas mecnicos nos seus estgios iniciais, poder evitar despesas maiores com reparos ou substituies futuras. O operador dever seguir rigorosamente o esquema de lubrificao e as instrues de manuteno dos equipamentos, fornecidas pelo fabricante. Devero ser usados leos e graxas apropriadas. Uma lubrificao deficiente poder ocasionar um superaquecimento nos mancais de apoio, enquanto que uma superlubrificao inadequada, pois significa desperdcio de dinheiro. Uma pintura dever ser feita periodicamente sempre que se fizer necessrio, dando-se especialmente ateno s partes de ferro. 3. Princpios de Operaes 3.1 Fatores de Controle No sistema de tratamento de esgoto pelo principio de lodos ativados, os principais fatores que controlam sua operao so: oxignio introduzido e o retorno de lodo.
_________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ________ _________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ _____

Srie Material de apio

Professor: Eng Osmar Mendes Ferreira, Ms

Pontifcia Universidade Catlica de Gois - Curso de Graduao Engenharia Ambiental Disciplina: Tratamento de Resduos Lquidos I e II

32

_________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ __ _______________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________

O oxignio introduzido no processo controlado atravs da profundidade de imerso dos aeradores, fator este que pode ser regulado atravs da variao do nvel do lquido no Reator Biolgico. Aumentando-se ou diminuindo-se a imerso, aumenta-se ou diminui-se, respectivamente, o fornecimento de oxignio pelo rotor. Cuidados especiais devem-se ter no aumento da imerso, para no sobrecarregar a potncia dos aeradores, e na diminuio, para no reduzir a velocidade do fluxo no Reator Biolgico, de tal forma que possa sedimentar os slidos em suspenso nele existentes. No fator retorno do lodo tem-se que considerar dois casos: a operao descontnua e a operao contnua. No primeiro caso, o sistema caracterizado pela no existncia de um decantador secundrio como componente da estao, utilizando-se o prprio reator como cmara de sedimentao, no existindo, portanto, a operao recirculao do lodo. Para que a sedimentao ocorra, os aeradores so interrompidos durante 20 a 30 minutos aproximadamente. Neste perodo a velocidade do fluxo diminui e os slidos sedimentados vo ao fundo, deixando na parte superior uma camada transparente, que descarregada por um dispositivo apropriado, que pode ser um sifo. Neste ltimo caso, o nvel do lquido baixo at o ponto onde o sifo perde a sua escorva. Os aeradores comeam a funcionar novamente quando j existe alguma submergncia. O ciclo reiniciado quando o nvel do lquido chega ao mximo, atravs do esgoto afluente ao reator. Segundo a maioria dos autores, o excesso de lodo deve ser retirado para os leitos de secagem quando se atingir a concentrao de 8.000 mg/L de slidos em suspenso no interior do Reator biolgico. No, entretanto, os autores de um trabalho apresentados no 8 Congresso Brasileiros de engenharia Sanitria afirmam que, aps 8 anos de experincia operacional verificaram que os nveis de MLSS (3.000 a 8.000 mg/L) encontrados na bibliografia especializada so praticamente inatingveis em unidades de operao intermitente, desde que se queira obter um certo grau de clarificao no efluente, deixando transparecer ser mais coerente a obteno de valores at 3.000 mg/L. O segundo caso, ou seja, a operao contnua muito mais simples, mas requer um dispositivo de sedimentao. Todo o lodo ativado, contendo normalmente uma concentrao de 1 a 2% de slidos, deve ser retornado o mais breve possvel, para que se obtenha uma concentrao de slidos em suspenso na mistura lquida da ordem de 6.000 mg/L, este retorno poder ser feito atravs de bombas centrfugas. A taxa de retorno de lodo poder ser verificada observando-se o decantador secundrio, pois quando este retorno est sendo feito apropriadamente, o nvel do manto de lodo no incio est perto do fundo do clarificador e seu crescimento lento durante o perodo de 1 a 4 semanas, tempo este necessrio para que a quantidade dos slidos aumente. Se o bombeamento no suficiente, este nvel crescer rapidamente. O nvel do manto de lodo deve crescer at a geratriz inferior do tubo do efluente decantador, aproximadamente ao mesmo tempo em que se chega a concentrao de 8.000 mg/L de slidos em suspenso no interior do Reator Biolgico. Neste ponto necessrio se fazer descargas do lodo em excesso. A freqncia de remoo do excesso de lodo vai depender da qualidade do efluente que se quer obter e da carga que a estao suporta.
_________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ________ _________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ _____

Srie Material de apio

Professor: Eng Osmar Mendes Ferreira, Ms

Pontifcia Universidade Catlica de Gois - Curso de Graduao Engenharia Ambiental Disciplina: Tratamento de Resduos Lquidos I e II

33

_________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ __ _______________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________

Pode-se operar um Reator Biolgico sem praticamente se remover o excesso de lodo, havendo com isto, no entanto, perda da eficincia no tratamento, pois o efluente final apresentar alguma DBO e slidos em suspenso. Para se obter um efluente altamente clarificado, necessria a remoo do excesso de lodo quando a estao estiver em plena carga. A taxa de retorno de lodo vai depender dos slidos inertes do esgoto bruto e da DBO removida diariamente, fatores determinantes no crescimento dos slidos em suspenso na mistura lquida. Normalmente quando os slidos decantveis atingirem o valor de 550 a 650 mL/L, e a concentrao de slidos em suspenso chegar a 8.000 mg/L, ou o nvel de OD atingir valores inferiores a 0,5 mg/L no Reator, o excesso de lodo dever ser removido para que a qualidade do efluente no seja afetada. Este excesso ser ento encaminhado para o espessador de lodo, devendo a concentrao de lodo ser diminuda em cerca de 90% em um nico dia, para que possibilite o rpido crescimento dos slidos. A remoo de apenas uma pequena parte resultar um rpido retorno das condies anteriores, necessitando, portanto que esta operao seja mais freqente. A experincia indica que com um lodo denso esta remoo poder ser feita em intervalos de 1 a 4 semanas. Marais recomenda que o sistema de recirculao permita uma razo de at 2:1, para que seja evitado o fenmeno da desnitrificao nos decantadores secundrios com o aparecimento de lodos ascendentes (rising sludge), que sero carreados com o efluente, prejudicando, portanto a qualidade do tratamento. Com este procedimento, o lodo permanecer menor tempo no decantador, ou seja, evitando condies anxicas (organismo aerbios em ambientes sem oxignio), fator este preponderante para que a desnitrificao ocorra. verdade que alguma parte do fenmeno (desnitrificao biolgica) acontece dentro do prprio reator. No entanto, isto se faz de uma maneira descontrolada devido ao aparecimento de regies com condies anxicas a montante dos rotores e ser casual. Outra recomendao feita pelo mesmo autor, como j foi citado anteriormente, que o descarte de lodo, resultante de uma remoo de 1/Rs de volume do tanque de mistura lquida, seja dirio, para que se obtenha um controle hidrulico da idade do lodo. 3.2. Teste de Controle 3.2.1 Observaes Gerais A cor e o odor so dois bons fatores de auxlio, independente de instrumentao na operao de estao. Com o esgoto normal, a mistura lquida no reator deve ter cor marrom escura. Se a cor mudar para marrom claro e os slidos ficarem mais fluidos a eficincia da estao deve ter diminudo e sua correo poder ser feita aumentando-se a concentrao de slidos em suspenso atravs do retorno do lodo. A cor preta significa estao sptica, que poder ser corrigido aumentando-se o fornecimento de oxignio atravs de uma imerso dos aeradores. O Reator Biolgico, quando bem operado, no apresenta odor objetvel, sendo comum o cheiro de terra. Se algum mau cheiro aparecer, deve-se inicialmente tentar localizar a causa, pois poder ser proveniente de falta de limpeza da estao, como, por exemplo, a no remoo de graxa e escuma que entraram para o estado sptico, no significando, portanto que a estao est mal operada. O mau cheiro persistindo, com caractersticas de ovos podres, acompanhando de uma cor escura da mistura lquida no Reator, significa que o processo passou de aerbio para anaerbio.
_________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ________ _________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ _____

Srie Material de apio

Professor: Eng Osmar Mendes Ferreira, Ms

Pontifcia Universidade Catlica de Gois - Curso de Graduao Engenharia Ambiental Disciplina: Tratamento de Resduos Lquidos I e II

34

_________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ __ _______________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________

3.2.2 Temperatura importante conhecer a temperatura do esgoto afluente a estao que deve ser alguns graus superiores da gua de abastecimento. Um aumento de temperatura pode ser causado pelo lanamento de esgoto industrial aquecido. A temperatura do esgoto tem efeito sobre a decantao e a atividade biolgica. medida que a temperatura cresce, a viscosidade do lquido diminui melhorando a sedimentabilidade. A atividade biolgica funo da temperatura e do tempo. medida que a temperatura aumenta na faixa de 7 oC a 40 oC, a atividade biolgica aumenta e vice-versa. 3.2.3 Slidos sedimentveis Os testes de slidos sedimentveis muito simples e o mais importante, podendo ser feito com dois cilindros graduados que so cheios com amostras da mistura lquida e do efluente do decantador at 1.000 mL, e deixados em repouso durante 30 minutos. Na amostra da mistura lquida do tanque de aerao, o operador deve observar a percentagem de volume atravs da leitura da escala do cilindro graduado, a transparncia do lquido sobrenadante acima do lodo e a densidade do lodo sedimentado, e do efluente clarificado, a existncia de lodo sedimentado e a transparncia do lquido sobrenadante. Quando o teste no reator apresentar um lquido sobrenadante turvo, mesmo que o lodo sedimentado seja denso, a estao est sendo mal operada. Neste caso, o efluente do clarificador tambm dever apresentar turbidez. Se o sobrenadante da mistura lquida for clarificado e o decantador for turvo, o problema se encontra nesta ltima unidade, sendo a causa usual deste fato a existncia de lodo no estado sptico no decantador. Se a mistura lquida do tanque de aerao tiver uma cor preta e com odor de ovo poder, o teste poder apresenta um sobrenadante turvo, podendo este fato ser ocasionado em razo de o oxignio fornecido ao sistema ser insuficiente ao o retorno do lodo ser demasiado. Para verificar esta ltima possibilidade, um teste completo de laboratrio dever ser realizado. Quando o sistema est sendo bem operado, os testes de slidos sedimentveis da mistura lquida apresenta um lodo de boa densidade e um sobrenadante clarificado, e o do efluente do clarificador mostra um leve trao de lodo sedimentado e uma quantidade irrisria de flocos suspensos no sobrenadante. De onde se conclui que a clarificao da amostra do efluente do decantador um indicador excelente de uma boa operao. 3.2.4 Estabilidade relativa O esgoto possui uma quantidade de matria orgnica, havendo inicialmente uma decomposio aerbica. Quando o oxignio disponvel se esgota, a decomposio passa a ser anaerbica, com produo de mau cheiro, caracterizando o estado sptico. O teste de estabilidade relativa muito simples, consistindo em, aps ser colhida a amostra no efluente do decantador, colocar-se uma soluo de azul de metileno, que na presena de oxignio conserva a cor, perdendo-a, porm quando o oxignio dissolvido se acaba. Este teste, portanto, mede a putrescibilidade do esgoto, ou seja, sua tendncia a tornar-se sptica, sendo interessante que seja feito pelo menos semanalmente. Os resultados so expressos em relao aos dias decorridos sem perda da cor azul, ou em percentual da estabilidade relativa. Se a cor permanecer 10 dias o efluente considerado estvel.
_________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ________ _________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ _____

Srie Material de apio

Professor: Eng Osmar Mendes Ferreira, Ms

Pontifcia Universidade Catlica de Gois - Curso de Graduao Engenharia Ambiental Disciplina: Tratamento de Resduos Lquidos I e II

35

_________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ __ _______________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________

3.2.5 Slidos em suspenso na mistura lquida (Teor de resduo seco) Esses slidos correspondem aos slidos totais contidos no tanque de aerao. No sistema de lodos ativados, esse teor geralmente superior ao de outros processos convencionais, oscilando entre 4 a 8 gr/L. para um ndice de Mohlman 70, valor considerado usualmente para uma boa operao, significar 280 a 560 mL de lodo por litro da mistura lquida no tanque de aerao. 3.2.6 Oxignio dissolvido As instrues para realizao deste teste so geralmente fornecidas pelo fabricante do aparelho, ou se encontram no Standard Methodos. O valor do oxignio dissolvido preconizado no funcionamento do Reator Biolgico em torno de 2 mg/L. concentrao de OD, acima de 4 mg/L, pode resultar uma nitrificao excessiva, aumentando a possibilidade do aparecimento do lodo flutuante no decantador secundrio, ocasionado por uma desnitrificao nessa unidade. Para diminuir o oxignio dissolvido, aumenta-se o retorno de lodo ou diminui-se a imerso dos aeradores. 3.2.7 pH O pH outro teste de realizao muito simples, que dever ser feito no esgoto bruto afluente e no Reator Biolgico. O pH do esgoto domstico normal aproximadamente 7. Um pH baixo pode ser fatal para os microorganismos existentes no processo, podendo este fato ser ocasionado, por exemplo, por uma nitrificao excessiva. Os valores de pH devem ser anotados para que as variaes sejam corrigidas, antes que tragam problemas operao da estao. 3.2.8 Cloro residual O teste de cloro residual feito para assegurar a garantia da qualidade do efluente no que se refere ao aspecto bacteriolgico. O efluente do decantador secundrio clorado, devendo-se deixar um cloro residual mnimo de 1,0 mg/L, valor este que assegura, aps a passagem pelo tanque de contato, praticamente que todas as bactrias sejam destrudas. 3.2.9 Outros testes O teste de Cloreto, Dureza, Alcalinidade, Demanda Bioqumica de Oxignio, Demanda Qumica de Oxignio, Nitrognio Amoniacal, Nitritos, Nitratos, Fosfatos, Contagem Total de Bactrias, Coliformes, podero ser feitos no sentido de avaliar a eficincia do tratamento, auxiliando na correo das deficincias da operao. Entretanto, devido ao fato de estes exigirem maiores cuidados na sua determinao e uma instruo e materiais reagentes mais onerosos, geralmente no feitos nos laboratrios de rotina da estao. Parmetros como ndice de Lodo ou ndice de Mohman, Idade do Lobo so tambm importantes no controle da operao. 4 Avaliao do Desempenho Providenciar anlise dos afluentes e efluentes mensalmente, e/ou, com maior freqncia se for necessrio, para verificar a reduo da Carga de DBO. A eficincia prevista expressa em percentagem na reduo da Carga de DBO pode ser calculada observando que. A eficincia
_________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ________ _________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ _____

Srie Material de apio

Professor: Eng Osmar Mendes Ferreira, Ms

Pontifcia Universidade Catlica de Gois - Curso de Graduao Engenharia Ambiental Disciplina: Tratamento de Resduos Lquidos I e II

36

_________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ __ _______________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________

parcial ou total esperada pode ser expressa em percentagem (E), e obtida conforme a formula: E = X - Y x 100. X X, o parmetro inicial ou na forma bruta. Y, o parmetro final ou tratado. 4.1 Parmetros a serem analisados Deve ser recomendada a realizao de Anlises Ambientais daqueles parmetros estabelecidos pela legislao ambiental em nvel federal, estadual e municipal quando for o caso, segundo a tipologia da atividade que deu origem ao esgoto a ser tratado. Ainda recomendada a realizao das anlises dos parmetros mnimos para controle de efluentes lquidos, apresentados pela NBR 9897 (ABNT, 1987). Estes devem ser realizados pela prpria empresa, quando dispuser de laboratrio especifico, ou ser solicitado sua realizao em laboratrios credenciados. Tabela 1: Exemplo dos parmetros a serem analisados para controle operacional de estao de tratamento de esgoto urbano
Acidez Alcalinidade Alumnio Carbanato orgnico total Cloretos Coliformes fecais Coliformes totais Cor DBO 520 C DQO Sulfetos Turbidez
Fonte: NBR 9897 (ABNT, 1987).

Dureza Fosfatos Fsforo total Materiais flutuantes Mercaptans Mercrio Nquel N-Amoniacal N-Nitrato N-Nitrito Sufactantes

N-Orgnico N-Total leos e Graxas Organoclorados pH Slidos sedimentaveis Slidos dissolvidos Slidos no filtrveis Slidos totais Sulfatos Temperatura

4.2 Pontos de coleta para anlise Efluente bruto, coleta composta; Efluente tratado, coleta simples.

Melhores pontos para coleta das amostras. Efluente bruto, na entrada da ETE; Aps o decantador primrio; Aps o tanque de aerao; Aps o decantador secundrio.

_________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ________ _________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ _____

Srie Material de apio

Professor: Eng Osmar Mendes Ferreira, Ms

Pontifcia Universidade Catlica de Gois - Curso de Graduao Engenharia Ambiental Disciplina: Tratamento de Resduos Lquidos I e II

37

_________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ __ _______________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________

ANEXO IV 1. Reator U.A.S.B. ( Upflow Anaerobic Sludge Blanket Reactors ) O efluente entrando pela base do reator tem sua velocidade de ascenso reduzida, permitindo que os slidos sedimentares encontrem um ponto de equilbrio entre a fora ascensional e a gravidade, estacionado a uma determinada altura. Estes slidos estacionados e distribudos em toda seo transversal do reator, serve de suporte para o desenvolvimento de bactrias anaerbias em face de ausncia do oxignio. A medida que o manto de lodo se forma e torna mais denso, passa a funcionar como um filtro, retendo tambm os slidos de menores dimenses que, nos processos clssicos de decantao, dificilmente so removidas. A massa biolgica, representada pelo manto de lodo, apresenta condies ideais no que se refere a relao alimento / bactria. No inicio do processo, o reator deve ser inoculado com substrato ativo, para acelerar o desenvolvimento do manto de lodo, a relao de 1/3 do volume do reator, (para cada caso especifico observar as condies do dimensionamento do equipamento). A eficincia do processo, alm de depender da temperatura e acidez, tambm dependente do tempo de reteno hidrulica, ou seja, o tempo disponvel para que as bactrias utilizem o substrato, em seu metabolismo. Os gases escapam na forma de bolhas formada pela coliso das microbolhas produzidas. Eventualmente pequenas bolhas podem arrastar materiais slidos que devem ser separados do efluente final do reator, na cmara de decantao. Sendo a unidade fechada, o biogs produzido pode ser acumulado num gasmetro permitindo seu aproveitamento. As principais tarefas a ser realizada pelo operador so: Verificar possveis entupimentos no sistema de alimentao do reator. Limpar a calha coletora de efluente. Drenar parte do lodo do reator periodicamente ou de acordo com as especificaes do projeto ou segundo observaes prticas, esgotando todo lodo com colorao escura ou negra. Verificar e concertar vazamentos. Completar o selo hdrico para evitar o vazamento de gs. 2. Partida do Reator. A partida do reator pode ser definida como o perodo de transio inicial, marcado por instabilidades operacionais. Basicamente, a partida pode ser conseguida de trs formas distintas. a) Utilizando-se de lodo de inculo adaptado ao esgoto a ser tratado, ou seja; de lodo gerado em um sistema similar, para a mesma origem do efluente: A partida do sistema procede-se de forma rpida e satisfatria, no havendo a necessidade de aclimatao do lodo. b) Utilizando-se de lodo de inculo no adaptado ao esgoto a ser tratado, ou seja; de lodo
_________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ________ _________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ _____

Srie Material de apio

Professor: Eng Osmar Mendes Ferreira, Ms

Pontifcia Universidade Catlica de Gois - Curso de Graduao Engenharia Ambiental Disciplina: Tratamento de Resduos Lquidos I e II

38

_________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ __ _______________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________

gerado em sistemas biolgicos anaerbios, e em qualquer tipo de efluente: Nesse caso, a partida do sistema passa por um perodo de aclimatao, incluindo uma fase de seleo microbiana, que pode ser de dois a quatro meses. c) Sem a utilizao de lodo de inculo: Essa considerada a forma mais desfavorvel de se proceder partida do sistema, uma vez que haver a necessidade de se inocular o reator com os prprios microorganismos contidos no esgoto afluente. Como a concentrao de microorganismos no esgoto muito pequena, o tempo demandado para reteno e seleo de uma elevada massa microbiana pode ser bastante prolongado, de quatro a seis meses. NOTA: Recomendamos que seja adotado somente a primeira ou a Segunda soluo, para proceder a partida do reator. 3. Inoculao do Reator. A inoculao pode-se dar tanto com o reator cheio ou vazio. Recomendamos a inoculao com o reator vazio para as instalaes ao nvel do solo e cheio para as instalaes com o reator enterrado, adotando-se os seguintes procedimentos: a) Transferir o lodo de inculo para o reator, cuidando para que o mesmo seja descarregado no fundo do reator, evitar turbulncia e contato excessivo com o ar. b) Deixar o lodo em repouso por um perodo aproximado de 12 a 24 horas, possibilitando a sua adaptao gradual temperatura ambiente. 4. Alimentao do Reator Com Esgoto. a) Aps o perodo de repouso, iniciar a alimentao do reator com esgoto, at que o mesmo atinja aproximadamente a metade de seu volume til. b) Deixar o reator sem alimentao por um perodo de 24:00 horas. Ao trmino deste perodo, e antes de iniciar uma prxima alimentao, coletar amostras do sobrenadante do reator e efetuar as seguintes anlises: temperatura, PH, alcalinidade, cidos volteis e DQO. Caso estes parmetros estejam dentro das faixas de valores aceitveis, prosseguir o processo de alimentao. Valores aceitveis. PH entre 6,8 a 7,4. cidos volteis, abaixo de 200 mg / L. ( como cido actico ) DQO, at 1,60 vezes da DBO a ser aplicada.

c) Continuar o processo de enchimento do reator, at que o mesmo atinja seu volume total, (nvel dos vertedores do decantador). d) Deixar o reator novamente sem alimentao por um perodo de 24:00 horas. Ao trmino deste perodo, retirar novas amostras para serem analisadas e proceder como anteriormente. e) Caso os parmetros analisados estejam dentro das faixas estabelecidas. Propiciar a
_________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ________ _________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ _____

Srie Material de apio

Professor: Eng Osmar Mendes Ferreira, Ms

Pontifcia Universidade Catlica de Gois - Curso de Graduao Engenharia Ambiental Disciplina: Tratamento de Resduos Lquidos I e II

39

_________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ __ _______________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________

alimentao continua do reator, de acordo com a quantidade de inculo utilizada e com a percentagem de vazo a ser aplicada, em 1/3. f) Implantar e proceder ao monitoramento de rotina do processo de tratamento. g) Proceder o aumento gradual da vazo afluente, inicialmente a cada quinze dias, de acordo com a resposta do sistema. Este intervalo poder ser ampliado ou reduzido, dependendo dos resultados obtidos. 5. Correo de Eventuais Problemas. 5.1. Desprendimento de odores desagradveis
Possveis causas Sobrecarga de esgoto com conseqente diminuio do tempo de deteno Elevadas concentraes de compostos de enxofres no esgoto afluente Elevadas concentraes de cidos volteis no reator, alcalinidade reduzida e queda de PH Presena de substncias txicas no efluente Queda brusca na temperatura do efluente Possveis solues Diminuir a vazo afluente unidade com problema Verificar a possibilidade de reduzir as concentraes de sulfetos no sistema Adicionar soluo de soda custica, a fim de elevar a alcalinidade do reator e manter o PH prximo de 7.0 ( 6,8 a 7,4 ) Localizar e eliminar as fontes de substncias txicas Caso o reator no seja coberto, avaliar a possibilidade de cobri-lo

5.2. Efluente contendo elevado teor de slidos suspensos


Possveis causas Sobrecarga na vazo de esgoto, com conseqente elevao das velocidades superficiais Elevada concentrao de slidos suspensos no afluente Excesso de slidos no reator Possveis solues Diminuir a vazo afluente unidade com problemas Verificar possibilidade de remoo de slidos a montante dos reatores Proporcionar o descarte do excesso de slidos presentes no sistema

5.3. Queda da produo de biogs


Possveis causas Possveis solues Vazamento nas tubulaes de gs Corrigir os vazamentos Entupimento nas tubulaes de gs Desentupir as tubulaes de gs Defeitos nos medidores de gs Reparar os medidores de gs Elevada concentrao de cidos volteis no Adicionar soluo de soda custica, a fim de reator, Alcalinidade reduzida e queda no PH elevar a alcalinidade do reator e manter o PH prximo de 7.0 ( 6,8 a 7,4 ) Presena de substncias txicas nos esgotos Localizar e eliminar as fontes de substncias txicas Queda brusca na temperatura dos esgotos Caso o reator no seja coberto, avaliar a possibilidade de cobri-lo

5.4. Queda da eficincia do sistema.


Sobrecarga Possveis causas de esgoto com Possveis solues conseqente Diminuir a vazo afluente unidade com
Professor: Eng Osmar Mendes Ferreira, Ms

_________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ________ _________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ _____

Srie Material de apio

Pontifcia Universidade Catlica de Gois - Curso de Graduao Engenharia Ambiental Disciplina: Tratamento de Resduos Lquidos I e II

40

_________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ __ _______________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________

diminuio do tempo de deteno problema Elevadas concentraes de cidos volteis no Adicionar soluo de soda custica, a fim de reator, alcalinidade reduzida e queda de PH elevar a alcalinidade do reator e manter o PH prximo de 7.0 ( 6,8 a 7,4 ) Perda excessiva de slidos no sistema, com Diminuir a vazo afluente unidade com reduo do leito e da manta de lodo problema ou retirar temporariamente o reator de operao Presena de substncias txicas nos esgotos Localizar e eliminar as fontes de substncias txicas Queda brusca na temperatura dos esgotos Eventualmente, retirar o reator de operao at que ocorra a reduo dos cidos volteis

5.5. Flutuao de grnulos


Possveis causas Sobrecarga de esgoto com conseqente diminuio do tempo de deteno Reinicializao da operao do sistema, aps longos perodos de paralisao Possveis solues Diminuir a vazo afluente unidade com problema Reinicializar o sistema com a aplicao de menores cargas volumtricas

5.6 Proliferao de insetos. Possveis causas


Presena de camadas de escumas e leos que normalmente se forma nos reatores anaerbios

Possveis solues
Aplicar dosagem adequada de algum tipo de inseticida, de modo a no prejudicar o funcionamento do reator Remover a camada de escuma e aterrar adequadamente Caso o reator no seja coberto, avaliar a possibilidade de cobri-lo

6. Avaliao do Desempenho Providenciar anlise dos afluentes e efluentes mensalmente, e/ou, com maior freqncia se for necessrio, para verificar a reduo da Carga de DBO. A eficincia prevista expressa em percentagem na reduo da Carga de DBO pode ser calculada observando que. A eficincia parcial ou total esperada pode ser expressa em percentagem (E), e obtida conforme a formula: E = X - Y x 100 (%) X X, o parmetro inicial ou na forma bruta. Y, o parmetro final ou tratado.

6.1 Parmetros a serem analisados

Devem ser recomendados a realizao de Anlises Ambientais daqueles parmetros estabelecidos pela legislao ambiental em nvel federal, estadual e municipal quando for o caso, segundo a tipologia da atividade que deu origem ao esgoto a ser tratado.
_________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ________ _________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ _____

Srie Material de apio

Professor: Eng Osmar Mendes Ferreira, Ms

Pontifcia Universidade Catlica de Gois - Curso de Graduao Engenharia Ambiental Disciplina: Tratamento de Resduos Lquidos I e II

41

_________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ __ _______________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________

Ainda recomendada a realizao das anlises dos parmetros mnimos para controle de efluentes lquidos, apresentados pela NBR 9897 (ABNT, 1987). Estes devem ser realizados pela prpria empresa, quando dispuser de laboratrio especifico, ou ser solicitado sua realizao em laboratrios credenciados. Tabela 1: Exemplo dos parmetros a serem analisados para controle operacional de estao de tratamento de esgoto urbano Acidez Dureza N-Orgnico Alcalinidade Fosfatos N-Total Alumnio Fsforo total leos e Graxas Carbanato orgnico total Materiais flutuantes Organoclorados Cloretos Mercaptans pH Coliformes fecais Mercrio Slidos sedimentaveis Coliformes totais Nquel Slidos dissolvidos Cor N-Amoniacal Slidos no filtrveis DBO 520 C N-Nitrato Slidos totais DQO N-Nitrito Sulfatos Sulfetos Sufactantes Temperatura Turbidez
Fonte: NBR 9897 (ABNT, 1987).

6.2 Pontos de coleta para anlise Efluente bruto, coleta composta; Efluente tratado, coleta simples.

Melhores pontos para coleta das amostras. Efluente bruto, na entrada da ETE; Aps o tratamento preliminar; Aps a unidade de tratamento fsico-qumico (quando for o caso); Aps o reator U.A.S.B.; Efluente tratado.

_________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ________ _________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ _____

Srie Material de apio

Professor: Eng Osmar Mendes Ferreira, Ms

Pontifcia Universidade Catlica de Gois - Curso de Graduao Engenharia Ambiental Disciplina: Tratamento de Resduos Lquidos I e II

42

_________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ __ _______________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________

REFERNCIAS Aisse, Miguel Mansur. Sistemas econmicos de tratamento de esgotos sanitrios. Rio de Janeiro ABES 2000. Chernicharo, Carlos Augusto de Lemos (Coordenador). Ps-tratamento de efluentes de reatores anaerbios. Projeto PROSAB. Belo Horizonte, 2001. Chernicharo, Carlos Augusto de Lemos. Princpios do tratamento biolgico de guas residurias reatores anaerbios. v. 5. Belo Horizonte , DESA/UFMG, 1997. Jordo, Eduardo Pacheco e Constantino Arruda Pessoa. Tratamento de esgotos domsticos. Ed. SEGRAC, 4 ed. Rio de Janeiro - 2005. Kellner, Erick e Pires, Eduardo Cleto. Lagoas de estabilizao - projetos e operao . Rio de Janeiro ABES, 1998. Nunes, Jos Alves. Tratamento fsico-qumico de guas residurias industriais. 2 Edio, grfica J. Andrade. Aracaju, 1996. Uehara, Michele Yukie [et al.]. Operao e manuteno de lagoas anaerbias e facultativas. So Paulo, CETESB, 1989. Von Sperling, Marcos (1997). Princpios do tratamento biolgico de guas residurias Lagoas de estabilizao, v. 3. Belo Horizonte (MG), DESA/UFMG. Von Sperling, Marcos, (1996). Princpios do tratamento biolgico de guas residurias princpios bsico do tratamento de esgoto, v. 2. Belo Horizonte (MG), DESA/FMG. Von Sperling, Marcos. Princpios do tratamento biolgico de guas residurias - lodos ativados. v. 4. Belo Horizonte, DESA/UFMG, 1997.

_________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ____________ ________ _________ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ _____

Srie Material de apio

Professor: Eng Osmar Mendes Ferreira, Ms

Você também pode gostar