Escolar Documentos
Profissional Documentos
Cultura Documentos
VCC
R1 =
10 kW
T2
ii
→
T1
R3 =
io
9 kW ←
+
+
vi
R2 = R4 = vO
- 1 kW 10 kW
-
ioA
←
iiA +
→ R1 =
T1 10 kW T2
+ +
viA
- R4 =
vo
R3 = 10 kW
iif iof
vi 9 kW
→ ←
+
vf R2 = -
1 kW
- -
MINISTÉRIO DA EDUCAÇÃO
SECRETARIA DE EDUCAÇÃO TECNOLÓGICA
INSTITUTO FEDERAL SUL-RIOGRANDENSE – IF-SUL
ENGENHARIA ELÉTRICA
- -
! 10 k $! 1 $
(
A = −100 ()(1 k + 9 k ) / /10 k *+ # −100
"
) &## &
1 0k +10 k %" 10 k + (1 k / /9 k ) (100 +1) &%
A = (−500 k ) (−50 ) ( 9, 9108 ×10 −6 )
A = 247, 77 V/V
A = Av1 ⋅ Av2
A = −4, 9554 ⋅ −50
A = 247, 77 V/V
Av = 247, 77
vi '
Zi ' =
ii '
Zi ' = hie1 + ( R2 / /R3) (1+ h fe1 )
1×10 3 ⋅ 9 ×10 3
Zi ' = 10 ×10 3 + (1+100)
1×10 3 + 9 ×10 3
Zi ' = 100, 9 kΩ
vo '
Zo ' =
io '
Z o ' = R4 / / ( R2 + R3)
Z o ' = 10 ×10 3 / /10 ×10 3
10 ×10 3 ⋅10 ×10 3
Zo ' =
10 ×10 3 +10 ×10 3
Z o ' = 5 kΩ
O coeficiente de realimentação é
vf
r=
vo
R2
vo
r = R2 + R3
vo
1×10 3
r=
1×10 3 + 9 ×10 3
r = 0,1
MINISTÉRIO DA EDUCAÇÃO
SECRETARIA DE EDUCAÇÃO TECNOLÓGICA
INSTITUTO FEDERAL SUL-RIOGRANDENSE – IF-SUL
ENGENHARIA ELÉTRICA
O ganho a malha fechada para um circuito com realimentação tensão-série (ver aula 08, slide 32) é
vo
Ar =
vi
A
Ar =
1+ rA
247, 77
Ar =
1+ 0,1 . 247, 77
A = 9, 61 V/V
vi
Zir =
ii
Zir = Z 'i (1+ rA)
Zir = 100, 9x10 3 (1+ 0,1 . 247,77)
Zir = 2, 60 MΩ
vo
Z or =
io
Z o'
Z or =
1+ rA
5x10 3
Z or =
1+ 0,1 . 247,77
Z or = 193, 97 Ω
Observação: O circuito é um amplificador de tensão. Quanto à entrada e saída, a topologia pode ser
chamada de série-paralelo (series-shunt) ou tensão-tensão.