COBERTURA
COTA EXTERNA
SPLIT 18000BTU'S
SPLIT 12000BTU'S
DML DML
SPLIT 9000BTU'S
A=5,06m² A=3,54m²
PROJ.COBERTURA
P=9,72m
RACK
P=7,66m COMPRESSOR
PD=3,00m PD= 3,00m
A=3,54m²
SPLIT 12000BTU'S
ESCRITÓRIO TI E ENG. CLÍNICA
A=10,97m² P=7,66m
A=11,49m² PD= 3,00m
P=14,19m
P=13,66m
PD= 3,00m
PD= 3,00m
REFEITÓRIO
A=18,90m²
P=17,40m
PD= 3,00m
E04
E01 P02
E06 E06
CA E01 AC1
E06 E06
E07
CONFORTO
A=18,90m²
WD8668 P=17,40m
PD= 3,00m
EXPURGO CA PREPARO DISTRIBUIÇÃO
A=56,05m² A=93,72m² A=72,03m²
P=32,00m P=51,17m P=38,65m
PD= 3,00m E07 PD= 3,00m
PD= 3,00m
E01 AC1
WD8668
AR
A= 16,05m²
E03
P=16,96m²
CA
P02
S363
E05
E03
DEPÓSITO
A=10,50m²
S363
E05
P=13,40m
PD= 3,00m
A=12,42m² A=5,90m²
P=14,96m P=14,96m P=11,72m
MAT SUJO PD= 3,00m
GARAGEM
A=14,95m²
A=11,64m²
P=14,10m
PD= 3,00m PD= 3,00m
GARAGEM
A=14,95m²
PRESSÃO ENTRE 6 E 8 BAR
P=15,63m PD= 3,00m
WC SUJO MASC SAÍDA DE MATERIAL P=15,63m
PD= A=8,53m² WC LIMPO MASC
A=8,53m²
A=12,11m²
P=14,24m
PD=
P=11,70m P=11,70m PD= 3,00m
E04 E04
PD= 3,00m PD= 3,00m
CA PONTO DE AR COMPRIMIDO H=96mm
MATERIAL
SAÍDA DE
ENTRADA DE
MATERIAL
PROJ.COBERTURA PISTOLA DE AR
PONTO DE AR COMPRIMIDO
ESCALA 1/100
PROJ.COBERTURA PROJ.COBERTURA
DML DML
PROJ.COBERTURA
A=5,06m² A=3,54m²
P=9,72m
RACK
P=7,66m COMPRESSOR
PD=3,00m PD= 3,00m
A=3,54m²
ESCRITÓRIO TI E ENG. CLÍNICA
A=10,97m² P=7,66m
A=11,49m² PD= 3,00m
P=14,19m
P=13,66m
PD= 3,00m
PD= 3,00m
REFEITÓRIO
A=18,90m²
P=17,40m
PD= 3,00m
E04
E01
E06 E06
E07
OSMOSE
A=8,55m²
P=11,70m
CONFORTO
A=18,90m²
WD8668 P=17,40m
PD= 3,00m
EXPURGO PREPARO DISTRIBUIÇÃO
A=56,05m² A=93,72m² A=72,03m²
P=32,00m P=51,17m P=38,65m
PD= 3,00m E07 PD= 3,00m
PD= 3,00m
E01
REVISÕES
WD8668
AR
A= 16,05m²
E03
P=16,96m² No. MODIFICACÕES DATA
01 EMISSÃO INICIAL
S363
E05
E03
DEPÓSITO
A=10,50m²
S363
E05
P=13,40m
PD= 3,00m
A=12,42m² A=5,90m²
P=14,96m P=14,96m P=11,72m
MAT SUJO PD= 3,00m PD= 3,00m PD= 3,00m
GARAGEM
A=14,95m²
A=11,64m² GARAGEM
A=14,95m²
P=14,10m
P=15,63m PD= 3,00m
WC SUJO MASC SAÍDA DE MATERIAL P=15,63m
PD= A=8,53m² WC LIMPO MASC
A=8,53m²
A=12,11m²
P=14,24m
PD=
P=11,70m P=11,70m PD= 3,00m
PD= 3,00m PD= 3,00m
E04 E04
BP SERVICOS DE ESTERILIZACAO SPE AUTOR(A) DO PROJETO DE ARQUITETURA RESPONSÁVEL TÉCNICO
MATERIAL
SAÍDA DE
ENTRADA DE
MATERIAL S.A. CNPJ - 21.821.773/0003-70 JEAN FARIA DOS SANTOS JEAN FARIA DOS SANTOS
PROPRIETÁRIO CAU A28580-3 CAU A28580-3
RRT Nº - RRT Nº -
COLABORADOR(A): ARQª CAROLINA MONYZE
UADRO DE PONTOS DE ÁGUA E ESGOTO
PROJ.COBERTURA CME - CENTRAL DE MATERIAL ESTERILIZADO - JOÃO LÚCIO
CLIENTE
Faria Arquitetura & CEP 69057-025 - (92) 3877-4548 | 99178-0800 ADRIANÓPOLIS -MANAUS/AM
Consultoria AV. ANDRÉ ARAÚJO, 97. SALA 1208 EMAIL - arq.jeanfaria@hotmail.com
ED. FÓRUM BUSINESS CENTER DIREITOS AUTORAIS RESERVADOS