Você está na página 1de 8

UNIVERSIDAD PONTIFICIA BOLIVARIANA

SECCIONAL BUCARAMANGA

FACULTAD DE INGENIERÍA CIVIL

PRÁCTICAS DE LABORATORIO HIDRÁULICA DE CANALES

PRÁCTICA NO. 5

SALTO HIDRÁULICA

INTEGRANTES:

Andrés Camilo Castaño Saiz ID: 000345587

María Del Pilar Chiappe Chinchilla ID: 000383284

Camilo Andrés Tavera Camargo ID: 000405782

Raúl Ernesto Hernández Villalba ID: 000334809

DOCENTE:

Juan Carlos Forero Sarmiento

31/08/2021
Práctica No. 5: RESALTO HIDRÁULICO

1. Objetivos
 …..
2. Marco teórico

3. Materiales

-Cinta métrica:

-Limnimetro:

-Compuertas:

-Caudalímetro:
-Caudal rectangular:

4. Procedimiento en el laboratorio
 ….
5. Datos recolectados
No. b (cm) Q (lpm) LR (cm) Y1 (mm) Y2 (mm)
1 492 26 14,9 85,6
2 30 306 14 13,6 58,9
3 223 10 3,8 40,5

6. Cálculos
Primeramente se deben pasar las unidades de caudal de lpm a cm 3/s
3 3
L 1000 cm 1min cm
Q 1 ( lpm ) =492 × × =8200
min 1l 60 seg seg
3
L 1000 cm 1min cm3
Q 2 ( lpm ) =306 × × =5100
min 1l 60 seg seg
3 3
( ) L 1000 cm 1min cm
Q 3 lpm =223 × × =3716.666
min 1l 60 seg seg
Pasar unidades de altura (Y) de mm a cm
1 cm
Y 1−1 ( mm )=14.9 mm × =1.49 cm
10 mm
1 cm
Y 1−2 ( mm )=13.6 mm × =1.36 cm
10 mm
1cm
Y 1−3 ( mm ) =3.8 mm× =0.38 cm
10 mm
1 cm
Y 2−1 ( mm )=85.6 mm× =8.56 cm
10 mm
1 cm
Y 2−2 ( mm )=58.9 mm × =5.89 cm
10 mm
1 cm
Y 2−3 ( mm ) =40.5 mm × =4.05 cm
10 mm
Hallar valor del caudal por unidad de ancho para cada caudal
3
cm
) Q(
( )
2
cm s
q =
s b(cm)

8200 (
s )
3
cm
q 1( ) =273.3333 (
s )
2 2
cm cm
=
s 30 ( cm )
3
cm
5100( )
( ) ( )
2 2
cm s cm
q2 = =170
s 30(cm) s
3
cm
3716.666 ( )
( ) ( )
2 2
cm s cm
q3 = =123.8888
s 30 (cm) s

Hallar valor de energía para cada una de las alturas


2
q
E=Y + 2
2 × g ×Y
*NOTA: usar la gravedad en cm/seg2 (g=981 cm/seg2)

( )
2 2
cm
273.333
seg
E 1−1=1.49 cm+ =18.6419561 cm
cm 2
2 ×981 2
× 1.49 cm
seg

( )
2
cm 2
170
seg
E 1−2=1.36 cm+ =9.32381244 cm
cm 2
2 ×981 2
×1.36 cm
seg

( )
2 2
cm
123.8888
seg
E 1−3=0.38 cm+ =54.5549501 cm
cm 2
2 × 981 × 0.38 cm
seg 2

( )
2 2
cm
273.333
seg
E 2−1=8.56 cm+ =9.079683183 cm
cm 2
2 × 981 2
×8.56 cm
seg

( )
2
cm2
170
seg
E 2−2=5.89 cm+ =6.314588523 cm
cm 2
2 ×981 2
×5.89 cm
seg
( )
2 2
cm
123.8888
seg
E 2−3=4.05 cm+ =4.526931126 cm
cm
2× 981 2
× 4.05 cm 2
seg
Hallar número de Froude para los valores de Y1


2
q
FR= 3
g×Y 1


2
273.333
FR 1−1= 3
=4.79820381
981× 1.49


2
170
FR 1−2= 3
=3.42220527
981× 1.36

FR 1−3=
√ 123.8882
981 ×0.38
3
=16.8858318

Hallar la Y2 teórica

Y 1× [−1+ √ 1+ 8( Fr 1 ) ]
2

Y 2T =
2

1.49 cm × [−1+ √1+8 ( 4.798203812 ) ]


Y 2T −1= =9.39308084 cm
2

1.36 cm× [ −1+ √1+8 ( 3.42220527 2) ]


Y 2T −2= =5.93706428 cm
2

0.38 cm× [−1+ √ 1+ 8 ( 16.8858318 ) ]


2
Y 2T −3= =8.88645438 cm
2
Hallar valor de ∆E

∆ E=E 1−E 2
∆ E 1=18.6419561−9.079683183=9.562272878cm
∆ E 2=9.32381244−6.314588523=3.009223914 cm
∆ E 3=54.5549501−4.526931126=50.02801893 cm
Hallar PRt

E2
PRt=1−
E1
9.079683183
PRt 1=1− =0.512943644
18.6419561
6.314588523
PRt 2=1− =0.32274608
9.32381244
4.526931126
PRt 3=1− =0.917020708
54.5549501
Hallar PR experimental

∆E
PRexp=
E1
9.562272878
PRexp1= =0.512943644
18.6419561
3.009223914
PRexp 2= =0.32274608
9.32381244
50.02801893
PRexp3= =0.917020708
54.5549501
Hallar Longitud real teórica

LRt =9.75 ×Y 1×(FR 1−1)1.01

LRt 1=9.75 ×1.49 ×( 4.79820381−1)1.01=55.91971277 cm

LRt 2=9.75 × 1.36×(3.42220527−1)1.01=32.40384733cm

LRt 3=9.75× 0.38 ×(16.8858318−1)1.01 =60.50736942cm


7. Presentación de resultados

No. q (cm2/s) E1 E2 Fr1 Y2t (cm) DE (cm)


1 273,333333 18,6419561 9,079683183 4,79820381 9,39308084 9,562272878
2 170 9,32381244 6,314588523 3,42220527 5,93706428 3,009223914
3 123,888889 54,5549501 4,526931126 16,8858318 8,88645438 50,02801893

PRt Prexp LRt (cm) fórmula Tipo de resalto


0,512943644 0,512943644 55,91971277 Permanente o Estable
0,32274608 0,32274608 32,40384733 Oscilante
0,917020708 0,917020708 60,50736942 Fuerte

8. Preguntas y conclusiones

- Basados en el número de Fr1, ¿qué tipo de resaltos se dieron en cada caso de caudal?
En el caudal 1 presentamos un fr de 4.78 lo que nos da entender que nuestro caudal es de
tipo permanente, en el caudal numero dos se presenta un fr menor al anterior de 3.42 lo
que nos indica que este caudal es de tipo oscilantes y por último nuestro caudal numero 3
nos arroja un fr de 16.88 dándonos a entender que este caudal es de tipo fuerte debido a
su elevado fr.

- Para cada caso, ¿Cuál fue el error entre la longitud del resalto teórica y experimental?

Caudal 1:
LRt= 55,919
LR=26
%error=53,504

Caudal2:
LRt=32,403
LR=14
%error=56,794

Caudal 3:
LRt=60,507
LR=10
%error=83,472
- ¿Qué relación se puede establecer entre Fr1y LR?

Podemos decir que Fr y Lr son directamente proporcionales, debido a que en la formula de


LRt se observa que si Fr aumenta LR aumentara proporcionalmente.

- ¿Cuál fue el error entre las alturas Y2teórica y experimental?

N1:
Y2=8,56
Y2t=9,393
%error=8,86

N2:
Y2=5,89
Y2t=5,937
%error=0,791

N3:
Y2=4,05
Y2t=8,886
%error=54,422
- Con los datos tomados en este experimento, ¿Puede construir una curva de energía
específica? ¿Porqué?

Si es posible debido a los datos que presentamos, con la ayuda de la altura supercrítica,
subcrítica el caudal y la base podemos hallar Yc y de esta forma empezar a crear la curva
de energía.

9. Referencias

Você também pode gostar