1.

INTRODUO ...................................................................................................................... 2

2.

PRINCPIO DE FUNCIONAMENTO. .................................................................................... 3

3.

CONSTRUO. .................................................................................................................... 4

4.

SELEO DE TAMANHO. ................................................................................................... 8

5.

INSTALAO. ...................................................................................................................... 9

6.

OPERAO. ......................................................................................................................... 9

7.

MANUTENO. .................................................................................................................. 10

8.

FRMULAS E TABELAS. .................................................................................................. 10

9.

MEDIDOR DE NVEL. ......................................................................................................... 11

10. CERTIFICADO DE GARANTIA .......................................................................................... 12

______________________________________________________________________
1

Calha Parshall

1.

Incontrol

INTRODUO

O medidor Parshall desenvolvido pelo engenheiro Ralph L. Parshall, na dcada


de 1920, nos Estados Unidos, uma melhoria realizada no projeto de calha
Venturi. Desenvolvido inicialmente para aplicaes em irrigao, hoje em dia
utilizado frequentemente nas aplicaes industriais e de saneamento.

______________________________________________________________________
2

Calha Parshall

2.

Incontrol

PRINCPIO DE FUNCIONAMENTO

O medidor Parshall, tambm conhecido por Calha Parshall, um medidor de


vazo para canais abertos. A calha constituda de uma estrutura com
paredes verticais, possuindo na entrada um trecho convergente (0-1), um
trecho contrado em declive de seo constante (1-2), e na sada um trecho
divergente em aclive (2-3).

Figura 1
O trecho convergente, tambm chamado de crista, produz um nvel, no lquido
medido, que est diretamente relacionado com a vazo.
Com auxlio de um medidor de nvel externo adequado, podemos obter leituras
de vazo com uma boa preciso.

______________________________________________________________________
3

Calha Parshall

3.

Incontrol

CONSTRUO

Os tamanhos das Calhas Parshall so designados pela largura da garganta


(trecho contrado).
A norma vigente no Brasil a norma NBR/ISO9826:2008. Porm, tendo em
vista ser uma norma relativamente nova, a grande maioria das calhas Parshall
existentes obedecem norma ASTM 1941:1975.
Neste manual apresentamos os dados das duas normas. Portanto, verificar por
qual norma foi fabricada a sua calha para utilizar corretamente os dados aqui
apresentados.
Os tamanhos disponveis so os apresentados nas tabelas abaixo:
3.1

NORMA NBR/ISSO 9826:2008

As tabelas a seguir apresentam, respectivamente, as caractersticas de vazo


das calhas Parshall de pequenas e grandes dimenses:

Calha
Parshall
n

1
1
2
3
4
5
6
7
8
9
10
11
12
13

Largura
da
Garganta

Equao
da

b
(m )

Q = Ch

vazo

Intervalo de
Altura

1)

ha
(m )

n
a

2)

Limite
modular

Razo de
Submergncia

(experimental)

(recomendado)

Intervalo de
Vazo

Q
-3

(x10 m /s)

(m / s )

min .

max .

min .

max .

0,03
0,03
0,03
0,03
0,05
0,06
0,06
0,06
0,06
0,06
0,08
0,08
0,08

0,45
0,60
0,75
0,75
0,75
0,75
0,75
0,80
0,80
0,80
0,80
0,80
0,80

1,5
3,0
3,5
4,5
12,5
25,0
30,0
30,0
35,0
45,0
80,0
95,0
100,0

100
250
400
630
850
1100
1250
1500
2000
2500
3000
3600
4000

0,55
0,62
0,64
0,66
0,67
0,68
0,70
0,72
0,74
0,76
0,78

0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,7
0,7
0,7
0,7
0,7
0,7

1, 580
a
1, 513
a
1, 521
a
1, 537
a
1, 548
a
1, 557
a
1, 565
a
1, 569
a
1, 577
a
1, 586
a
1, 593
a
1, 599
a
1, 605
a

0,152
0,381 h
0,25
0,561 h
0,30
0,679 h
0,45
1,038 h
0,60
1,403 h
0,75
1,772 h
0,90
2,147 h
1,00
2,397 h
1,20
2,904 h
1,50
3,668 h
1,80
4,440 h
2,10
5,222 h
2,40
6,004 h
1) C = CDb 3,279 n onde
C D o coeficiente de descarga
n um expoente dependente de b
2) Valores arredondados

Tabela 1

______________________________________________________________________
4

Calha Parshall

Incontrol
Equao da

Calha
Parshall
n

Largura
da
Garganta

b
(m )

1)

vazo
Condio de
escoamento
livre

Q = C1 ha1, 6

Intervalo de
Altura

Intervalo de
Vazo

ha
(m )

Q
( m3 / s )

Razo de
Submergncia

Coeficiente de
Submergncia
(Fator de Correo)

(recomendado)

Cs

Min

Max

]Min

Max

( m3 / s )
1

14

3,05

7,463 ha1, 6

0,09

1,07

0,16

8,28

0,80

1,0

3,68

1, 6
a

0,09

1,37

0,19

14,68

0,80

1,2

1, 6
a

0,09

1,67

0,23

25,04

0,80

1,5

1, 6
a

0,09

1,83

0,31

37,97

0,80

2,0

1, 6
a

0,09

1,83

0,38

47,16

0,80

2,5

9,14

1, 6
a

21,44 h

0,09

1,83

0,46

56,33

0,80

3,0

12,19

28,43 ha1, 6

0,09

1,83

0,60

74,70

0,80

4,0

15,24

1, 6
a

0,09

1,83

0,75

93,04

0,80

5,0

15
16
17
18
19
20
21

4,57
6,10
7,62

9,859 h
10,96 h
14,45 h
17,94 h

35,41 h

1) C1 = C Db , onde C D o coeficiente de descarga

Tabela 2

Figura 2
______________________________________________________________________
5

Calha Parshall

Calha
Parshall
n
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21

Incontrol

Garganta
b
0,152
0,250
0,300
0,450
0,600
0,750
0,900
1,000
1,200
1,500
1,800
2,100
2,400
3,050
3,660
4,570
6,100
7,620
9,140
12,190
15,240

l
0,305
0,600
0,600
0,600
0,600
0,600
0,600
0,600
0,600
0,600
0,600
0,600
0,600
0,910
0,910
1,220
1,830
1,830
1,830
1,830
1,830

X
0,050
0,050
0,050
0,050
0,050
0,050
0,050
0,050
0,050
0,050
0,050
0,050
0,050
0,305
0,305
0,305
0,305
0,305
0,305
0,305
0,305

Seo de Entrada
Y
0,075
0,075
0,075
0,075
0,075
0,075
0,075
0,075
0,075
0,075
0,075
0,075
0,075
0,230
0,230
0,230
0,230
0,230
0,230
0,230
0,230

hp1
0,115
0,230
0,230
0,230
0,230
0,230
0,230
0,230
0,230
0,230
0,230
0,230
0,230
0,343
0,343
0,457
0,686
0,686
0,686
0,686
0,686

b1
0,400
0,780
0,840
1,020
1,200
1,380
1,560
1,680
1,920
2,280
2,640
3,000
3,380
4,760
5,610
7,620
9,140
10,670
12,310
15,480
18,530

l1
0,610
1,325
1,350
1,425
1,500
1,575
1,650
1,700
1,800
1,950
2,100
2,250
2,400
4,270
4,880
7,620
7,620
7,620
7,930
8,230
8,230

le
0,622
1,352
1,377
1,454
1,530
1,607
1,683
1,734
1,836
1,989
2,142
2,295
2,448
-

Seo de Sada

la
h2
l2
hp2
0,415 0,390 0,610 0,012
0,900 0,550 0,920 0,072
0,920 0,600 0,920 0,072
0,967 0,750 0,920 0,072
1,020 0,900 0,920 0,072
1,074 1,050 0,920 0,072
1,121 1,200 0,920 0,072
1,181 1,300 0,920 0,072
1,227 1,500 0,920 0,072
1,329 1,800 0,920 0,072
1,427 2,100 0,920 0,072
1,534 2,400 0,920 0,072
1,632 2,700 0,920 0,072
1,830 3,660 1,830 0,152
2,030 4,470 2,440 0,152
2,340 5,590 3,050 0,203
2,840 7,320 3,660 0,305
3,350 8,940 3,960 0,305
3,880 10,570 4,270 0,305
4,880 13,820 4,880 0,305
5,890 17,270 6,100 0,305

Altura
da
Parede
hc
0,600
0,800
0,950
0,950
0,950
0,950
0,950
1,000
1,000
1,000
1,000
1,000
1,000
1,220
1,520
1,830
2,130
2,130
2,130
2,130
2,130

Tabela 3
3.2

NORMA ASTM 1941:1975

Largura da
Garganta

Capacidade de Vazo

Min

Max

(inch)

(m /h)

(m /h)

1.02

19.4

2.04

47.9

3.06

115

5.10

398

9.17

907

12

11.2

1641

18

15.3

2508

24

42.8

3374

36

62.2

5138

48

132

6922

60

163

8726

72

265

10551

84

306

12376

96

357

14221

Tabela 4

______________________________________________________________________
6

Calha Parshall

Incontrol

Figura 3
DIMENSES
E
T
G

2/3A

[inch]

[mm]

[mm]

[mm]

[mm]

[mm]

[mm]

[mm]

[mm]

[mm] [mm]

1
2
3
6
9
12
18
24
36
48
60
72
84
96

363
414
467
621
880
1372
1448
1524
1677
1829
1981
2134
2286
2438

242
276
311
414
587
914
965
1016
1118
1219
1321
1423
1524
1625

356
406
457
610
864
1343
1419
1495
1645
1794
1943
2092
2242
2391

93
135
178
394
381
610
762
914
1219
1524
1829
2134
2438
2743

168
214
259
397
575
845
1026
1207
1572
1937
2302
2667
3032
3397

229
254
610
610
762
914
914
914
914
914
914
914
914
914

76.2
114
152
305
305
610
610
610
610
610
610
610
610
610

203
254
305
610
457
914
914
914
914
914
914
914
914
914

19.0
22.2
25.4
76.2
76.2
76.2
76.2
76.2
76.2
76.2
76.2
76.2
76.2
76.2

305
305
381
381
381
381
457
457
457
457
457

[mm]

[mm]

[mm] [mm]

[mm]

28.6
42.9
57.2
114.3
114.3
228.6
228.6
228.6
228.6
228.6
228.6
228.6
228.6
228.6

902
1080
1492
1676
1854
2223
2711
3080
3442
3810
4172

406
406
508
508
508
508
610
610
610
610
610

12.7
25.4
38.1
76.2
76.2
76.2
76.2
76.2
76.2
76.2
76.2
76.2
76.2
76.2

7.94
9.52
25.4
50.8
50.8
50.8
50.8
50.8
50.8
50.8
50.8
50.8
50.8
50.8

Tabela 5
Obs.: As medidas correspondentes calhas Parshall com largura de garganta
de 1 e 2 no constam na norma ASTM 1941:1975, embora seus valores
sejam determinados matematicamente baseados na mesma.
______________________________________________________________________
7

Calha Parshall

Incontrol

Os medidores Parshall podem ser construdos no campo ou fabricados nos


seguintes materiais:
a-)

Fibra de vidro

b-)

Ao carbono revestido

c-)

Ao inox

d-)

Concreto

4.

SELEO DE TAMANHO

Para a seleo do tamanho do medidor Parshall, devem ser conhecidos os


seguintes dados:
a-)

largura do canal na montante e na jusante;

b-)

vazes mxima e mnima;

c-)

profundidade da gua no canal;

d-)

perda de carga admissvel;

e-)

previso para vazes futuras.

As seguintes recomendaes devem ser levadas em conta:


a-)

Utilizar sempre escoamento livre, pois assim necessrio apenas um


medidor de nvel no trecho convergente;

b-)

Para se obter escoamento livre as seguintes condies devem ser


obedecidas:

Onde:

Norma NBR/ISO 9826:2008:


1-)

relao hb/ ha = 0,6 para medidores at 0,90 m;

2-)

relao hb/ ha = 0,7 para medidores at 2,40 m;

3-)

relao hb/ ha = 0,8 para medidores at 15,24 m.

Norma ASTM 1941:1975:


1-)

relao Hb/Ha < 0,6 para medidores at 22;

2-)

relao Hb/Ha < 0,7 para medidores de 30 a 40.

ha e Ha correspondem altura da lmina de gua a montante.


hb e Hb - correspondem altura da lmina de gua a jusante.

c-)

Carga total na crista do medidor no superior carga total na seo de


entrada;

d-)

Perda de carga no medidor no superior carga disponvel;

e-)

Caso tenha afogamento, obedecer os mximos citados anteriormente


(item b). Neste caso ser necessrio instalar um medidor de nvel tambm
no trecho contrado;
______________________________________________________________________
8

Calha Parshall

Incontrol

f-)

Obedecidas todas as condies citadas, escolher a calha de menor


largura.

5.

INSTALAO

Algumas condies bsicas de instalao devem ser obedecidas:


a-)

O medidor Parshall deve ser instalado precedido montante ou por um


reservatrio de grande dimenso, onde a velocidade seja sensivelmente
nula, ou por um trecho de canal prismtico onde o escoamento seja
uniforme;

b-)

O medidor deve estar instalado com o canal tanto na montante como na


jusante;

c-)

O medidor deve ser alinhado longe o suficiente da comporta ou curvas,


para que o escoamento na regio da entrada do medidor seja uniforme e
completamente livre de turbulncias, ondas ou vrtices;

d-)

A crista do medidor deve estar rigorosamente em nvel a fim de assegurar


a mesma vazo para o mesmo nvel ao longo da largura do medidor;

e-)

As paredes laterais do trecho contrado devem estar paralelas e verticais;

f-)

Pode-se construir com aclive de 1:4 uma rampa inicial no incio da seo
convergente;

g-)

Pode-se construir um degrau na sada ao fim da seo divergente (vide


figura 2);

h-)

Pode-se fazer uma concordncia em planta, na parte da entrada atravs


de raios convenientes, por exemplo, para medidores menores do que 12
um raio de 0,41 m, para medidores de 12 a 36 um raio de 0,51 m e para
medidores de 48 a 96 um raio de 0,61 m;

i-)

O medidor de nvel deve estar instalado de forma a medir o valor da altura


da lmina de gua a montante e da altura da lmina de gua a jusante.

6.

OPERAO

Operando-se com escoamento livre, basta uma medida da altura da lmina de


gua a montante para se conhecer a vazo. Esta medida feita na seo
convergente, crista, localizada a uma distncia de 2/3 do comprimento da
parede convergente.
Na operao no desejada, porm possvel, ou seja, condio de escoamento
por submerso, alm da medida na crista, ser preciso tambm uma medida
da altura da lmina de gua a jusante, num ponto prximo da seo final da
garganta.
Para medidores de 6 a 96, a posio dessa segunda medida dever ficar a 2
a montante da parte final da seo estrangulada.

______________________________________________________________________
9

Calha Parshall

Incontrol

As relaes Hb/Ha e que constitui a vazo de submerso na prtica no deve


ultrapassar 95%.

7.

MANUTENO

A manuteno de um medidor Parshall bastante simples, pois sua forma


construtiva dificulta o acmulo de sedimentos. Por isso, o medidor Parshall
comumente utilizado em esgoto e gua com slidos em suspenso
Porm, faz-se necessria uma vistoria cuja frequncia estudada caso a caso,
dependendo da sua condio de operao.
Alm do aspecto limpeza, observar as condies da calha propriamente dita,
pois dependendo do material de construo (se concreto, alvenaria, madeira,
metal ou fibra de vidro) pode ter tempo de vida varivel.

8.

FORMULAS E TABELAS

A funo matemtica para a norma ASTM 1941:1975 que expressa a vazo em


funo da altura :
Q = K x Hn
Onde:

K uma constante que depende das dimenses da calha e ajuste da


unidade de engenharia;
n um valor que difere ligeiramente de 3/2 (vide a tabela abaixo
para valores de K e n para diversos padres).
Valores de n K [para vazo em m3/h]
W
[inch]

[mm]

1
2
3
6
9
12
18
24
36
48
60
72
84
96

25,4
50,8
76,2
152,4
228,6
304,8
457,2
609,6
914,4
1219,2
1524,0
1828,8
2133,6
2438,4

1,550
1,550
1,547
1,580
1,530
1,522
1,538
1,550
1,556
1,578
1,587
1,595
1,601
1,606

217,29
434,58
633,60
1371,60
1926,00
2484,00
3794,40
5133,60
7855,20
10566,00
13420,80
16254,00
19101,60
21963,60

Tabela 6

______________________________________________________________________
10

Calha Parshall

9.

Incontrol

MEDIDOR DE NVEL

O medidor Parshall pode ser fornecido com escala graduada em vazo, nas
unidades de engenharia de sua escolha. As unidades mais comuns so: m3/h,
l/min, l/s ou m3/h.
Atualmente, o medidor de nvel mais utilizado na Calha Parshall do tipo
ultrassnico, por sua preciso (0,25% FE) e por sua praticidade, pois, como o
sensor no entra em contato direto com o fluido, no h problemas de
incrustaes. Alm disso, tambm temos a vantagem de transmitir distncia,
atravs sinal eltrico, os valores de vazo (instantnea ou totalizada), seja por
um sinal analgico 4-20 mA, seja por uma comunicao digital do tipo RS485.
O medidor de nvel ultrassnico possui um conversor com leitura direta ou
vazo, na unidade de engenharia desejvel, como tambm podendo totalizar o
volume do lquido que j passou pelo medidor Parshall.

Aviso:
Este manual poder ser alterado sem prvio aviso, pois os dados desse
documento so revisados periodicamente e as correes necessrias
sero consideradas nas prximas verses. Agradecemos por qualquer
tipo de sugesto que venha contribuir para a melhora deste documento.
______________________________________________________________________
11

Calha Parshall

Incontrol

10. CERTIFICADO DE GARANTIA


Este equipamento, Medidor de Vazo tipo Calha Parshall,
Modelo: ______________________
N. de srie: ___________________
garantido contra defeitos de mo de obra e material pelo prazo de 365 dias
da data de entrega. Esta garantia ser invalidada quando, a critrio de
julgamento da Incontrol, o equipamento tiver sido submetido a abusos ou
manuseios imprprios. Quando o reparo, dentro da garantia, for necessrio, o
usurio dever remeter o equipamento fbrica ou reposto, ficando as
despesas de seguro e frete por conta e risco do usurio.
Data de Entrega: ____/_____/_____

Incontrol

______________________________________________________________________
12

Você também pode gostar