INSTALAÇÕES ELÉTRICA MT E BT

TABELA DEMANDA
MOTORES

DISTÂNCIA EM ÂNGULO

CONVERSÃO m P/ Kg
CABOS

VÃO REGULADOR

TRAÇÃO
TABELA 16 e 17 ND 5.1 CEMIG - DEMANDA INDIVIDUAL - MOTORES
MOTORES MONOFÁSICOS MOTORES TRIFÁSICOS
Absorvida Absorvida Rede (kW)
POTÊNCIA CV QTDE MOTORES DEMANDA KVA POTÊNCIA CV QTDE MOTORES DEMANDA KVA
Rede (kW)
1/4 0.39 0 1/6 0.25 0
1/3 0.52 0 1/4 0.33 0
1/2 0.66 0 1/3 0.41 0
3/4 0.89 0 1/2 0.57 0
1 1.10 0 3/4 0.82 0
1.5 1.58 0 1 1.13 0
2 2.07 0 1,5 1.58 0
3 3.07 0 2 1.94 0
4 3.98 0 3 2.91 0
5 4.91 0 4 3.82 0
7.5 7.46 0 5 4.78 0
10 9.44 0 6 5.45 0
12.5 12.10 0 7.5 6.90 0
Total 0 0 0 10 9.68 0
12.5 11.79 0
15 13.63 0
Obs: Para limpar tela, tecle Ctrl + l 20 18.40 0
25 22.44 0
Soma dos Totais dos Mot. Monofásicos e Trifásicos 0 kVA 30 26.93 0
50 44.34 0
60 51.35 0
MENU 75 62.73 0
Total 0 0 0
DISTÂNCIA & ÂNGULO

Coordenadas Formato UTM: P1 P2 P3


Abscissa 391608 391641 391676 X
Ordenada 7967615 7967594 7967574 Y

P1 = A P2 = B P3 = C

40.31 79.40 39.12

6305 3150
3155 -3150
3153.5694062443 -0.9988681377

-> OBS: NA CALCULADORA CIENTIFICA


USAR FUNÇÃO:

POL( Y2-Y1,X2-X1) -> DISTÂNCIAS ENTRE


COORDENADAS
MENU

NGULO

DISTÂNCIA
P1/ P2 39.12 mts P1 a P2 = C
P2 / P3 40.31 mts P2 a P3 = A
P1 / P3 79.40 P1 a P3 = B

ÂNGULO 3
177.27368901
CABOS MULTIPLEX - 1KV
MENU

Peso Nominal
Condutor (metros) m/Kg
Cabo
1x10+10mm² 0.071 0
1x16+16mm² 0.110 0
1x25+25mm² 0.170 0

2x10+10mm² 0.131 0
2x16+16mm² 0.176 0
2x1x35+70mm² 0.390 0
2x70+70mm² 0.685 0

3x10+10mm² 0.176 0
3X16+16mm² 0.348 0
3x35+35mm² 0.5142 0
3x35+70mm² 0.530 0
3x70+70mm² 0.900 0

3x120+70 1.900 0

50mm² 0.260 0
120mm² 0.450 0
150mm² 0.590 0
CABO NÚ - BAIXA TENSÃO
3#4(4) CA 0.230 0
3#4 CA 0.170 0
3#2 CA 0.280 0
3#1/0 CA 0.440 0
3#4 CA 0.120 0
3#2 CA 0.180 0
3#1/0 CA 0.290 0
(4) CA 0.058 0
(2) CA 0.092 0

Peso Nominal
Condutor (metros) Qtd Fases Neutro m/Kg m/Kg +3% m/Kg +5%
Cabo
CAA 4 - 24,71mm² 0.086 3 0 0.0 0.00
CAA 2 - 39,22mm² 0.136 3 0 0 0
CAA 1/0 - 62,38mm² 0.216 1 0 0 0
CAA 3/0 - 99,23mm² 0.343 1 1 0 0 0
CAA 4/0 - 125,10mm² 0.433 1 1 0 0 0
CAA 336,4 - 198,30mm² 0.687 3 0 0 0
Fio Aluminzado 1N5 0.077 1 0 0 0

Fio Aluminzado 1N2 0.109 NEUTRO 1 0 0 0

Fio Aluminzado 3N5 0.168 1 0 0 0

CA 4 - 21,15mm² 0.058 3 1 0 0 0
CA 2 - 33,62mm² 0.092 1 1 0 0 0
CA 1/0 - 53,49mm² 0.145 1 0 0 0
CA 3/0 - 85,03mm² 0.232 1 1 0 0 0
CA 4/0 - 107,20mm² 0.293 1 1 0 0 0
CA 336,4 - 170,50mm² 0.467 3 0 0 0
CABO AÇO HS 3/8 (9,5MM²) 0.407 Mensageiro 0 0 0
VÃO REGULADOR

Distância Vãos de Estruturas Ancoradas


VÃO 1 (m) VÃO 2 (m) VÃO 3 (m) VÃO 4 (m) VÃO 5 (m) VÃO 6 (m) VR
Informar 100 150 120 128.43128

OBS: NÃO COLOCAR ZERO, DEIXAR OS VALORES EM BRANCO

Formula:

VÃO 1 VÃO 2 3
3 3 3
VÃO 1 VÃO 2 VÃO 3

DE VÃO ACORADO A VÃO ACORADO


MENU

VMÉDIO
123.3333

CÁLCULO DO VÃO REGULADOR

128.4 m Vão Regulador


Coéf. Resultante
Altura Poste Eng Alt Poste Livre Cabo Solo h/H
MáximoTraçã daN
11 1.7 9.1 7 0.77 o
381.15 293

Resultante

daN
Nº Fases 3 880

Obs: 7m altura que o neutro será instalado do solo


Coéf. Flecha
Altura Poste Eng Alt Poste Livre h/H
Máximo Resultante
9 1.5 7.3 4.87 Flecha
0.9264 6.37