Abstract: Despite being a very useful method, surface electromyography (sEMG) is a method that still conducts to
unsolved issues related to signal acquisition during isotonic contractions, mainly regarding to distance between
electrodes (DIE). The purpose of this study was to examine the effects of two different DIEs on sEMG amplitude in
isotonic contractions. Fifteen male subjects (22.8 3.6 years), all right-handed, performed isotonic contractions of
right biceps brachii while performed full elbow flexion-extension at 20% of maximum voluntary contraction (CVM),
and at three different cadences (30, 45 and 60 bpm). The sEMG signal acquisition was defined by means of two
channels (C1 and C2), whose DIEs were 4.2 and 13 cm, respectively. The evaluation of sEMG signals was performed
in the time domain by means of the root mean square (RMS value). The DIE and cadences were defined as factors.
Two-way ANOVA was applied for analysis ( = 0.05). There were not significant statistical differences between both
factors (P > 0.05). Despite of the absence of significant statistical differences between both factors in the sEMG
signal amplitude, the results suggest that special regard must be done in clinical conditions to these small variations
related to muscle force gradation properties.
Keywords: Surface electromyography. Interelectrodes distance. Biceps bachi. Isotonic contraction.
INTRODUO
1
17
A sEMG uma disciplina que lida com a deteco, anlise e o uso do sinal
eltrico que provm da contrao do tecido muscular esqueltico (DE LUCA, 2006).
Durante os ltimos dez anos, o conhecimento em torno desta tcnica e suas aplicaes
tm aumentado consideravelmente (HERMENS et al., 2000; MERLETTI et al., 2008) e
somando o conhecimento bsico da tcnica com a literatura cientfica disponvel,
possvel observar a aplicao da sEMG em diferentes reas tais como: Neurofisiologia,
Cinesiologia, Controle Motor, Psicologia, Medicina de Reabilitao e Engenharia
Biomdica (DE LUCA, 2006). Para cada uma destas reas, possvel estabelecer
diferentes condies quanto ao nvel de informao extrado do sEMG. Desta forma,
importante destacar que existem duas diferentes formas de aquisio deste sinal: sEMG
(no-invasiva) e EMG intramuscular (invasiva). O primeiro tipo conduz deteco de
nveis de atividade mioeltrica relativos a um grande nmero de unidades motoras
(UMs), isso pelo fato de os eletrodos estarem dispostos sobre a pele, levando captao
de um maior volume condutor (CHRISTENSEN et al., 1995; KAMEN et al., 1996). J
o EMG intramuscular, que pode ser feito atravs de agulha e/ou arame, permite analisar
UMs especficas (CHRISTENSEN et al., 1995; KAMEN et al., 1996).
Quanto s aplicaes da tcnica, o sinal de sEMG tem sido til em: 1)
determinar o tempo de ativao do msculo; que , avaliar o incio e o fim da contrao;
2) estimar a fora produzida pelo msculo; 3) e auxiliar no monitoramento da fadiga
muscular; entre outros (DE LUCA, 2002).
Quanto s formas de anlise do sEMG, propem-se comumente duas diferentes
abordagens, sendo estas realizadas nos domnios do tempo e da freqncia (HERMENS
et al., 2000; KAMEN et al., 1996). No domnio do tempo, comumente analisada a
amplitude do sinal de sEMG, refletindo os mecanismos de ativao das UMs que, por
sua vez, modulam a produo de torque (ou fora) em vrios msculos sob diferentes
condies de contrao (MALEK et al., 2005; KOSSEV et al., 1998; DE LUCA, 1997;
BECK et al., 2007). O primeiro mecanismo o recrutamento de UMs e o segundo a
modulao em freqncia da taxa de disparo das UMs j recrutadas (KAMEN et al.,
1996; KOSSEV et al., 1998; DE LUCA, 1997; BECK et al., 2007).
Um grande nmero de pesquisadores (ODA & MORITANI, 1994;
CHRISTENSEN et al., 1995; ELFVING et al., 2002) tem estudado os mecanismos de
gradao da fora muscular por meio de contraes isomtricas, permitindo com que
haja uma melhor compreenso dos mtodos de aquisio e anlise do sinal de sEMG
Arquivos em Movimento, Rio de Janeiro, v.4, n.2, julho/dezembro, 2008.
18
19
MATERIAIS E MTODOS
Sujeitos
Participaram do estudo quinze sujeitos do sexo masculino (idade: 22,8 3,6
anos; massa corporal: 75,5 11,6 kg; estatura: 1,76 0,09 m), destros, e sem histrico
de leses em membros superiores e coluna lombar. Todos os sujeitos eram
universitrios e praticantes de atividade fsica. Todos assinaram termo de
consentimento Livre e Esclarecido. O estudo foi submetido apreciao do CEP/UFRJ
e o mesmo est cadastrado sob o nmero 125/03. Para avaliar a dominncia de
membros superiores foi aplicado o Edinburgh Handedness Inventory (OLDFIELD,
1971).
20
21
Procedimento do teste
22
Figura 4: Posio adotada pelo sujeito para realizao dos testes de contrao.
23
AM B =
[C (T )]2
(4 )
(1)
Onde:
AMB representa a rea de seco transversa total do brao (cm2);
C permetro do brao (cm);
T a dobra cutnea triciptal (cm);
e , constante igual a 3,14...;
Determinada a rea de seco transversa total ocupada pelos msculos flexores e
extensores do cotovelo, o passo seguinte foi extrair aquela representada somente pela
parte
flexora.
Desta
forma,
seguinte
equao
A f = AM b 0,356
(2)
foi
aplicada:
(2)
24
Onde:
Af representa a rea dos msculos flexores do brao;
AMb representa a rea de seco transversa total do brao (cm2);
e 0,356 a rea relativa dos flexores primrios (bceps e o braquial) (ENOKA, 2000).
Determinada a rea dos msculos flexores, o passo seguinte foi calcular a fora
dos msculos flexores primrios do brao. A seguinte equao (3) foi estabelecida:
F f = 63 A f
(3)
Onde:
Ff a fora dos flexores primrios do brao;
63 a tenso especfica dos flexores (Newtons/cm2) (IKAI & FUKUNAGA, 1968);
e Af representa a rea de seco transversa dos msculos flexores do brao.
Em seguida, o ltimo passo foi estimar a capacidade mxima de gerao de
fora dos msculos flexores primrios do cotovelo. A seguinte equao (4) foi
estabelecida:
Cm =
(FF ) 3,5
(4)
BR
Onde:
Cm significa Carga Mxima;
Ff a fora dos flexores primrios do cotovelo;
3,5 o comprimento mdio da alavanca dos flexores do cotovelo (cm) (ENOKA, 2000);
e Br o brao de resistncia (cm) (Epicndilo lateral ao processo estilide do rdio).
O clculo resultante proporcionava uma estimativa da carga mxima, cujo
porcentual de 20% foi determinado arbitrariamente, sendo este utilizado para a etapa de
coleta.
25
Na realizao das tarefas, foram utilizadas anilhas e uma barra curta cuja massa
igual 200 gramas. Portanto, algumas vezes no foi possvel colocar as cargas
determinadas pela estimativa, fazendo com que as mesmas fossem arredondadas.
Anlise dos dados ou processamento do sinal
A amplitude do sinal foi calculada com base na raiz mdia quadrtica (valor
RMS), segundo equao abaixo:
EMG RMS =
1 2
x (t )dt
T 0
Onde,
T definido como perodo;
E x, o trecho de sinal vlido extrado a partir de T.
Cada perodo de sinal foi colhido a partir da utilizao de um cursor (disponvel
no software), que permitia a marcao dos trechos de interesse para anlise.
Arbitrariamente foram selecionados apenas os trechos intermedirios (ex: havendo 5
contraes concntricas e excntricas, a terceira era a escolhida). A partir destes trechos,
eram marcados o incio e o fim do burst (Fig. 5). Portanto, no foi possvel adquirir
janelas (T) de mesmo tamanho, sendo esta uma das limitaes do estudo.
(5)
26
Anlise Estatstica
Foram comparadas as mdias entre as 3 condies (cadncias) e as distncias C1
e C2, sendo ambas definidas como fatores. Desta forma, foi utilizada a anlise de
varincia para medidas repetidas (two way - ANOVA), sendo o nvel de significncia
adotado de () 0,05.
RESULTADOS
Figura 6: Valores mdios ( DP) dos valores RMS de C1 e C2 nas trs cadncias (30, 45 e 60bpm).
27
aumento das mesmas nas contraes dinmicas, como possvel observar na Fig. 6.
Entretanto, tambm no foi observada diferena estatstica significativa (F2,84 = 1,7086;
P = 0,187) entre as 3 cadncias. Alm disso, no foi observada interao entre ambos os
fatores (distncia e cadncia) na modulao da amplitude do sinal sEMG ((F2,84 =
0,08898; P = 0,914).
DISCUSSO
28
Neste
presente
estudo,
no
foram
observadas
diferenas
estatsticas
29
30
aquisio e anlise no oferecia tais ferramentas. Alm disso, uma das propostas deste
estudo foi tambm utilizar um sistema comercial de anlise para este tipo de
movimento, comum no processo de fortalecimento de pessoas saudveis e com algum
tipo de comprometimento neurolgico e/ou msculo-esqueltico de membros
superiores. Logo, suspeita-se que a inexistncia de diferenas estatsticas entre as
cadncias e as DIEs tenha ocorrido pela simplicidade do mtodo de anlise empregado,
no sendo o mesmo capaz de detectar variaes mnimas na amplitude do sinal de
sEMG e que provavelmente se assemelha queles comumente utilizados em clnicas,
academias de ginstica e/ou centros de treinamento.
CONCLUSO
Este estudo teve como objetivo analisar a influncia das diferentes DIEs (4,2 e
13 cm) na amplitude do sinal de sEMG em contraes dinmicas do BB. No foram
observadas diferenas estatsticas significativas na amplitude no sinal de sEMG nas
diferentes DIEs, assim como, no houve diferenas estatsticas significativas entre as
amplitudes dos sinais de sEMG de acordo com o aumento das cadncias.
Em outras investigaes sugere-se a anlise do sinal de sEMG em msculos
menores atravs de eletrodos descartveis como aqueles utilizados neste trabalho.
Assim, seria possvel verificar se o modelo de resposta dos eletrodos descartveis
comumente utilizados na clnica o mesmo tanto para msculos grandes, quanto para
msculos pequenos.
Sugere-se tambm que, apesar da ausncia de diferenas estatsticas nas
amplitudes dos sinais, quando comparadas em diferentes mbitos (clnico e desportivo,
por exemplo) onde so necessrias anlises a partir da EMG, faz-se necessrio ter
grande ateno, principalmente no que se refere ao clnico, pois pequenas variaes de
amplitude podero apresentar importante significado no processo de reabilitao do
paciente. Alm disso, estas pequenas diferenas podero no ser detectadas caso o
sistema de aquisio e anlise no possua ferramentas mais robustas de anlise e que
permitam um recorte detalhado dos sinais de sEMG, sendo este, portanto, outro
importante aspecto a ser considerado.
31
REFERNCIAS
BECK, T. W.; HOUSH, T. J.; JOHNSON, G. O.; WEIR, J. P.; CRAMER, J. T.;
COBURN, J.W.; MALEK, M.H. The effects of interelectrode distance on
electromyographic amplitude and mean power frequency during isokinetic and
isometric muscle actions of the biceps brachii. Journal of Electromyography and
Kinesiology, v. 15, n. 5, p. 482-495, 2005.
BECK, T. W.; HOUSH, T. J.; CRAMER, J. T.; WEIR, J. P. The effects of electrode
placement and innervation zone location on the electromyographic amplitude and mean
power frequency versus isometric torque relationships for the vastus lateralis muscle.
Journal of Electromyography and Kinesiology, in press, corrected proof, 2006.
BECK, T. W.; HOUSH, T. J.; JOHNSON, G. O.; CRAMER, J. T.; WEIR, J. P.;
COBUM, J. W.; MALEK, M. H. Electromyographic instantaneous amplitude and
instantaneous mean power frequency patterns across a range of motion during a
concentric isokinetic muscle action of the biceps brachii. Journal of
Electromyography and Kinesiology, v. 16, n. 5, p. 531-539, 2006.
BECK, T. W.; HOUSH, T. J.; MIELKE, M.; CRAMER, J. T.; WEIR, J. P.; MALEK,
M. H.; JOHNSON, G. O. The influence of electrode placement over the innervation
zone on electromyographic amplitude and mean power frequency versus isokinetic
torque relationships. Journal of Neuroscience Methods, v. 162, n. 1-2, p. 72-83, 2007.
CHRISTENSEN, H.; SOGAARD, K.; JENSEN, B. R.; FINSEN, L.; SJOGAAR, G.
Intramuscular and surface EMG power spectrum from dynamic and static contractions.
Journal of Electromyography and Kinesiology, v. 5, n. 1, p. 27-36, 1995.
DE LUCA, C. J. The use of surface electromyography in biomechanics. Journal of
applied Biomechanics, v. 13 n. 2, p. 135-163, 1997.
DE LUCA, C. J. Surface Electromyography: detection and recording. By Delsys
incorporated, 2002. <http://www.delsys.com/KnowledgeCenter/Tutorials.html>. Acesso
em: 10 maro, 2007.
DE LUCA, C. J. Electromyography. Encyclopedia of medical devices and
instrumentation.
John
G.
Webster
Editora,
2006.
Disponvel
em:
<http://www.delsys.com/KnowledgeCenter/Tutorials.html>. Acesso em: 10 maro,
2007.
ELFVING, B.; LILJEQUIST, D.; MATTSSON, E.; NMETH, G. Influence of
interelectrode distance and force level on the spectral parameters of surface
electromyographic
recordings
from
the
lumbar
muscles
Journal of Electromyography and Kinesiology, v. 12, n. 4, p. 295-304, 2002.
ENOKA, R. M. Bases Neuromecnicas da Cinesiologia. 2a ed. So Paulo Editora
Manole, 2000.
32
33
Contatos
gustfisio@click21.com.br
flaviaftank@gmail.com
rafaelba@bol.com.br
leo_fisioterapeuta@hotmail.com
oliveiracg@hotmail.com
marcoacg@unisys.com.br