Você está na página 1de 1

RELATÓRIO DE ENSAIO NÃO DESTRUTIVO

NDT REPORT
ULTRASSOM PHASED ARRAY
PHASED ARRAY ULTRASONIC TEST

RELATÓRIO REVISÃO PÁGINA STATUS


Report Rel. US-RAD-04/20 Revision 0 Page
1 de 1 Status
Emissão inicial

CLIENTE: OBRA: UNIDADE: DATA DE INSPEÇÂO


Client Job Unit: Inspection Date
KROMINOX Otacilio Costa Linha de fibras 08/10/2020
ÁREA INSPECIONADA
DESCRIÇÃO Inspected area
Description Tubo AI ASTM A358-TP304L CL2 C/C SCH. STD Ø 16"
Solda Longitudinal e Circunferencial da Tubulação de Inox
METAL BASE METAL DE ADIÇÃO PROCESSO DE SOLDAGEM CONDIÇÕES SUPERFICIAIS
Base Metal Weld Metal Welding Process Surface Conditions
AI ASTM A312 TP 304L _____ ______ Escovada
TÉCNICA APARELHO / NÚMERO DE SÉRIE ACOPLANTE ESPESSURA
Method Instrument / Serial Number Coupling Thickness

Phased Array PHASCAN QA002EEA092 Ultragel II Sonotech Ø16" - 4.2 mm


CABO COAXIAL BLOCO DE CALIBRAÇÃO PADRÃO DE REFERÊNCIA SENSIBILIDADE
Coaxial Handle Calibration Block Reference Standards Sensibility
- BL 101 RAD V1 Ø 2,4 x 80% x TCG
TRANSD./FREQ. (MHz) SAPATA FAIXA DE ÂNGULO NÚMERO DE SÉRIE PITCH/ELEVAÇÃO ELEMENTOS G. PRINCIPAL G. TRANSF. G. VARREDURA
Transducer/Frequency Wedge Angle Range Serial Number Pitch/Elevation Elements Principal Gain Transfer Gain Work Gain
D1-5L16-0.6*10 D1-N55S 42/70 0,6 16 42 0 46
DETALHE DE INSPEÇÃO LAMINADA FORJADO FUNDIDO SOLDA MEDIÇÃO DE ESPESSURA OUTROS
Inspection Detail Laminate Forged Casting X Weld Thickness Mensurement Others
PROCEDIMENTO DE INSPEÇÃO/Rev. NORMA/CRITÉRIO DE ACEITAÇÃO
Inspection Procedure/Rev. Code/Acceptance Standards
Solicitação do cliente A Pedido do cliente, isento de descontinuidades
REGISTROS DE RESULTADOS
Registers of the Results

JUNTA/PEÇA Nº IND. ÂNGULO LOCAL TAM. PROF. ALTURA DISTÂNCIA SUPERFÍCIE TIPO DEFEITO AMPLIT./ % SOLDADOR LAUDO
Joint/Piece Number Angle Place Size Depth Distance Surface Defect Type Amplit. Welder Certificate

TUB315020-SPOT1-L1 A
TUB315020-SPOT2-L2 A
TUB315020-SPOT3-L2 A
TUB315020-SPOT4-C2 A
TUB315020-SPOT5-C2 A
TUB315020-SPOT6-L3 A
TUB315020-SPOT7-L3 A
TUB315020-SPOT8-L4 A
TUB315020-SPOT9-L4 A
TUB315020-SPOT10-C4 A
TUB315020-SPOT11-C4 A
TUB315020-SPOT12-L5 A
TUB315020-SPOT13-L5 A
TUB315020-SPOT14-L6 A
TUB315020-SPOT15-L6 A
TUB315020-SPOT16-C6 A
TUB315020-SPOT17-L7 A
TUB315020-SPOT18-L7 A
TUB315020-SPOT19-L8 A
TUB315020-SPOT20-L8 A
TUB315020-SPOT21/22-L9 A
TUB315020-SPOT23/24-L10 A
A – APROVADO / Approved R – REPROVADO / Rejected REC – RECOMENDADO EXAME COMPLEMENTAR / Recommended Additional Test UNIDADE / Unit mm
LEGENDA / Legend Falta de fusão (FF) – Lack of Fusion Falta de penetração (FP) – Lack of Inclusão de Escoria (IE) - Porosidade (PO) – Mordedura (MO) –
Trinca (TR) – crack (CR)
(LF) Penetration (LP) Slag Inclusion (SI) Porosity (PO) Bite (BI)

CORRIDA - 040160H

Inspeção realizada nas juntas longitudinais e circunferenciais da Tubulação


OBSERVAÇÕES
Comments
Cada spot com dimensão de 400mm
As posições dos spots estão correlacionadas com as marcaçãoes feitas em campo

INSPETOR APROVAÇÃO INSPETOR AUTORIZADO CLIENTE / FISCALIZAÇÃO


Inspector Approval Autorized Inspector Client / Surveillance

Reginaldo Ferreira da Silva

US-PA - SNQC-3414

DATA / Date 08/10/2020 DATA / Date DATA / Date DATA / Date