Índice
3 Seções mínimas 08
Queda de tensão 09
Queda de tensão (Volt / Ampere x km) 10
Parâmetros elétricos 11
Comprimento máximo para cabo multipolar - 220 V Monofásico 12
4
Comprimento máximo para cabo multipolar - 220 V Trifásico 13
Comprimento máximo para cabo multipolar - 380 V 14
Comprimento máximo para cabo multipolar - 440 V 15
Capacidade de curto circuito 16
Certificações Condumax
Sistema da Garantia da Qualidade ISO 9002 / 94
Todos os produtos Condumax são fabricados rigorosamente de acordo com as
especificações NBR e controlados por um Sistema da Garantia da Qualidade conforme
NBR ISO 9002 / 94
Não aplicável
4
Capacidade de corrente em função do tipo de instalação 1
Base de dados NBR 5410
Seção A1 A2 B1 B2 C D E F G
mm2 2 3 2 3 2 3 2 3 2 3 2 3 2 3
CC CC CC CC CC CC CC CC CC CC CC CC CC CC A B C D E
1,5 19 17 18,5 16,5 23 20 22 19,5 24 22 26 22 26 23 27 21 22 30 25
2,5 26 23 25 22 31 27 30 26 33 30 34 299 36 32 37 29 30 41 35
4,0 35 31 33 30 42 37 40 35 45 40 44 37 49 42 50 40 42 56 48
6,0 45 40 42 38 54 48 51 44 58 52 56 46 63 54 65 53 55 73 63
10,0 61 54 57 51 75 66 69 60 80 71 73 67 86 75 90 74 77 101 88
16,0 81 73 76 68 100 88 91 80 107 96 95 79 115 100 121 101 105 137 120
25,0 106 95 99 89 133 117 119 105 138 119 121 101 149 127 161 135 141 182 161
35,0 131 117 121 109 164 144 246 128 171 147 146 122 185 158 200 169 176 226 201
50,0 158 141 145 130 198 275 175 154 209 179 173 144 225 192 242 297 216 275 246
70,0 200 179 183 164 253 222 222 194 269 229 213 178 289 246 310 268 279 353 318
95,0 241 216 220 197 306 269 269 233 328 278 252 211 352 298 377 328 342 430 389
120 278 249 253 227 354 312 312 268 382 322 287 240 410 346 437 383 400 500 454
150 318 285 290 259 407 358 358 307 441 371 324 271 473 399 504 444 464 577 527
185 362 324 329 238 464 408 408 348 506 424 363 304 542 456 575 510 533 661 605
240 424 380 386 346 546 481 481 407 599 500 419 351 641 538 679 607 634 781 719
Base de dados
5
DadosTécnicos
6
Notas sobre fator de correção para agrupamento
1) Os fatores são aplicados à grupos de cabos uniformemente carregados
2) Quando a distância horizontal entre cabos adjacentes for o dobro do seu diâmetro externo, não é necessário aplicar nenhum
fator de correção
3) Os valores indicados são médios para a faixa de seções nominais, com precisão de 5%
4) Os fatores são aplicáveis à cabos em uma única camada (exceto quando mencionado disposição em camadas)
5) Para os cabos dispostos em camadas, o fator total é obtido multiplicando os fatores referentes à disposição horizontal pelos
fatores referentes à disposição vertical
6) Distância mínima entre bandejas ou leitos na vertical 300 mm 2
7) Distância mínima entre bandejas ou leitos na horizontal 225 mm
8) Se um agrupamento é constituído de cabos bipolares e tripolares, o número total de cabos é considerado igual ao número de
circuitos e aplica-se à tabela de 03 condutores carregados
7
DadosTécnicos
8
Queda de tensão
Limite de queda de tensão
Instalações Iluminação Outros usos
A Alimentados diretamente por um ramal de baixa tensão,
a partir de uma rede de distribuição pública em baixa tensão 4% 4%
B Alimentados diretamente por subestação de transformação ou
transformador, a partir de uma instalação de média / alta tensão 7% 7%
C Instalações que possuam fonte própria geradora de energia 7% 7%
1) Volt / Ampere x km
(pág. 10)
2) Tabelas simplificadas de comprimentos máximos para cabos multipolares para determinação direta do lance máximo
permissível, nas condições estabelecidas.
(págs. 12, 13, 14 e 15)
3
Exemplo comparativo
9
DadosTécnicos
10
Parâmetros elétricos
Resistências elétricas e reatâncias indutivas (Xl) em Ohms / km
Resistência Cabos Antichama e Maxvinil (70 0C) e Cabos Maxlink e Maxlink G flex (90 0C)
Seção elétrica (70 °C) Cabos em Cabos unipolares ao ar livre Cabos
mm² Ohms / km dutos Circuitos FN e FF Circuitos trifásicos multipolares
CC CA 01 02 03 04 05 06 07 08 09 10 11 12 13
1,5 12,1 14,48 0,16 0,16 0,21 0,39 0,44 0,16 0,17 0,23 0,40 0,46 0,16 0,12 0,14
2,5 7,41 8,87 0,15 0,15 0,20 0,37 0,42 0,15 0,16 0,22 0,38 0,44 0,15 0,12 0,13
4,0 4,61 5,52 0,14 0,14 0,20 0,35 0,40 0,14 0,16 0,22 0,37 0,42 0,14 0,12 0,13
6,0 3,08 3,69 0,13 0,14 0,19 0,33 0,39 0,14 0,15 0,20 0,35 0,40 0,14 0,11 0,12
10,0 1,83 2,19 0,13 0,13 0,18 0,32 0,37 0,13 0,14 0,20 0,34 0,39 0,13 0,10 0,12
16,0 1,15 1,38 0,12 0,12 0,17 0,30 0,35 0,12 0,14 0,19 0,32 0,37 0,12 0,10 0,11
25,0 0,73 0,87 0,12 0,12 0,17 0,28 0,34 0,12 0,13 0,18 0,30 0,35 0,11 0,10 0,11
35,0 0,52 0,63 0,11 0,11 0,17 0,27 0,32 0,11 0,13 0,18 0,29 0,34 0,11
50,0 0,39 0,46 0,11 0,11 0,16 0,26 0,31 0,11 0,13 0,18 0,28 0,33 0,11
70,0 0,27 0,32 0,10 0,10 0,16 0,25 0,30 0,10 0,12 0,17 0,27 0,32 0,10
95,0 0,19 0,23 0,10 0,10 0,16 0,24 0,29 0,10 0,12 0,17 0,25 0,30 0,10
120,0 0,15 0,19 0,10 0,10 0,15 0,23 0,28 0,10 0,12 0,17 0,24 0,29 0,10
150,0 0,12 0,15 0,10 0,10 0,15 0,22 0,27 0,10 0,12 0,17 0,23 0,29 0,10
185 0,099 0,12 0,099 0,10 0,15 0,21 0,26 0,10 0,12 0,17 0,23 0,28 0,10
240,0 0,075 0,09 0,098 0,10 0,15 0,20 0,25 0,10 0,12 0,17 0,22 0,27 0,10
Observação:
Esta não é uma tabela para uso direto. Ela apresenta os parâmetros utilizados na determinação de V / A x km
Z = R Cos f + X Sen f
6 Trifólio 11 Trifólio
12 Bi e Tripolar 13 Tetrapolar
FN / FF / 3F 3F + N
11
DadosTécnicos
Metros
CV A 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220
1 10 1,5 1,5 1,5 2,5 2,5 2,5 4,0 4,0 4,0 6,00 6,00 6,00 6,00 6,00 6,00 10,0 10,0 10,0 10,0 10,0 10,0
1,5 13 1,5 1,5 2,5 2,5 4,0 4,0 4,0 6,00 6,00 6,00 6,00 6,00 10,0 10,0 10,0 10,0 10,0 10,0 10,0 10,0 3,08
2 15 1,5 2,5 2,5 4,0 4,0 4,0 6,00 6,00 6,00 6,00 10,0 10,0 10,0 10,0 10,0 10,0 10,0 16,0 16,0 16,0 16,0
2,5 17,5 1,5 2,5 2,5 4,0 6,00 6,00 6,00 6,00 10,0 10,0 10,0 10,0 10,0 10,0 10,0 16,0 16,0 16,0 16,0 16,0 16,0
3 20 2,5 2,5 4,0 4,0 6,00 6,00 6,00 10,0 10,0 10,0 10,0 10,0 10,0 16,0 16,0 16,0 16,0 16,0 16,0 16,0 16,0
3,5 22 2,5 2,5 4,0 6,00 6,00 6,00 10,0 10,0 10,0 10,0 10,0 16,0 16,0 16,0 16,0 16,0 16,0 16,0 16,0 25,0 25,0
4 24 2,5 4,0 4,0 6,00 6,00 10,0 10,0 10,0 10,0 10,0 16,0 16,0 16,0 16,0 16,0 16,0 16,0 25,0 25,0 25,0 25,0
4,5 26 2,5 4,0 4,0 6,00 6,00 10,0 10,0 10,0 10,0 16,0 16,0 16,0 16,0 16,0 16,0 25,0 25,0 25,0 25,0 25,0 25,0
5 28 2,5 4,0 4,0 6,00 10,0 10,0 10,0 10,0 10,0 16,0 16,0 16,0 16,0 16,0 25,0 25,0 25,0 25,0 25,0 25,0 25,0
5,5 30 2,5 4,0 6,00 6,00 10,0 10,0 10,0 10,0 16,0 16,0 16,0 16,0 16,0 25,0 25,0 25,0 25,0 25,0 25,0 25,0 25,0
6 32 2,5 4,0 6,00 6,00 10,0 10,0 10,0 16,0 16,0 16,0 16,0 16,0 25,0 25,0 25,0 25,0 25,0 25,0 25,0 25,0 35,0
6,5 34 2,5 4,0 6,00 10,0 10,0 10,0 10,0 16,0 16,0 16,0 16,0 25,0 25,0 25,0 25,0 25,0 25,0 25,0 35,0 35,0 35,0
7 36 4,0 4,0 6,00 10,0 10,0 10,0 16,0 16,0 16,0 16,0 16,0 25,0 25,0 25,0 25,0 25,0 25,0 35,0 35,0 35,0 35,0
8 40 4,0 6,00 6,00 10,0 10,0 10,0 16,0 16,0 16,0 16,0 25,0 25,0 25,0 25,0 25,0 35,0 35,0 35,0 35,0 35,0 35,0
8 44 4,0 6,00 10,0 10,0 10,0 16,0 16,0 16,0 16,0 25,0 25,0 25,0 25,0 25,0 35,0 35,0 35,0 35,0 35,0 50,0 50,0
10 49 4,0 6,00 10,0 10,0 16,0 16,0 16,0 16,0 25,0 25,0 25,0 25,0 35,0 35,0 35,0 35,0 35,0 50,0 50,0 50,0 50,0
11 53 6,00 6,00 10,0 10,0 16,0 16,0 16,0 25,0 25,0 25,0 25,0 35,0 35,0 35,0 35,0 35,0 50,0 50,0 50,0 50,0 50,0
12 59 6,00 10,0 10,0 16,0 16,0 16,0 25,0 25,0 25,0 25,0 35,0 35,0 35,0 35,0 50,0 50,0 50,0 50,0 50,0 70,0 70,0
13 62 6,00 10,0 10,0 16,0 16,0 16,0 25,0 25,0 25,0 1,29 35,0 35,0 35,0 50,0 50,0 50,0 50,0 50,0 70,0 70,0 70,0
14 66 6,00 10,0 10,0 16,0 16,0 25,0 25,0 25,0 25,0 35,0 35,0 35,0 35,0 50,0 50,0 50,0 0,74 70,0 70,0 70,0 70,0
15 70 6,00 10,0 10,0 16,0 16,0 25,0 25,0 25,0 1,3 35,0 35,0 35,0 50,0 50,0 50,0 50,0 0,70 70,0 70,0 70,0 70,0
Observações:
1) Até 35 mm², utilizar cabo multicondutor. Acima de 35 mm² recomendamos e adotamos cabos singelos
2) Considerado comprimento do quadro de comando à bomba (queda tensão máxima 4%),
respeitar limite de queda de tensão de 3% do transformador ao quadro de comando
12
Lances máximos em função da máxima queda de tensão
Tabela simplificada
Observações:
1) Até 35 mm², utilizar cabos multicondutores. Acima de 35 mm² recomendamos e adotamos cabos singelos
2) Considerado comprimento do quadro de comando à bomba (queda tensão máxima 4%),
respeitar limite adicional de queda de tensão de 3% do transformador ao quadro de comando
13
DadosTécnicos
Observações:
1) Até 35 mm², utilizar cabos multicondutores. Acima de 35 mm² recomendamos e adotamos cabos singelos
2) Considerado comprimento do quadro de comando à bomba (queda tensão máxima 4%),
respeitar limite adicional de queda de tensão de 3% do transformador ao quadro de comando
14
Lances máximos em função da máxima queda de tensão
Tabela simplificada
Observações:
1) Até 35 mm², utilizar cabos multicondutores. Acima de 35 mm² recomendamos e consideramos o uso de fases singelas
2) Considerado comprimento do quadro de comando à bomba (queda tensão máxima 4%),
respeitar limite adicional de queda de tensão de 3% do transformador ao quadro de comando
15
DadosTécnicos
Capacidade de curto-circuito
As curvas seguintes fornecem para cada seção condutora a corrente máxima de curto-circuito para tempos entre
0,1 seg (1 ciclo) à 1,4 segundos (100 ciclos)
I² t = I² (x + X²+ 4 z S / 2 z S)
z = I² / a - Y / S
a = K² S² ln (F f + b / F i + b)
Onde:
Condutor K b Isolação X Y
Cobre 226 234,5 PVC < 3 Kv 0,29 0,06
Alumínio 148 228 PVC > 3 Kv 0,27 0,05
XLPE 0,41 0,12
EPR < 3 Kv 0,38 0,10
EPR > 3 Kv 0,32 0,07
16
Correntes máximas de curto-circuito (Conexão soldada)
Cabos com isolantes termofixos (90 °C) Maxlink / Maxlink G Flex
10 x 200
100
90
80
70
60
50
40
30
20
o
cl
ci os
1 cl
ci
2
os
cl
ci
4 os
10 cl
ci
9 8 os
cl
ci
Corrente de Curto Circuito (Kiloamperes)
8
16 os
cl
7
ci
30 os
6 cl
ci os
60 cl
5 ci
0
10
4
1
0.9
0.8
0.7
0.6
0.5
0.4
5
0.3
0.2
4
16
10
25
35
240
150
500
630
800
1000
2,5
185
300
50
95
400
1,5
70
120
0.1
1
5
3
2
9
7
8
60
100
250
30
80
40
900
600
200
700
20
17
DadosTécnicos
10 x 200
100
90
80
70
60
50
40
30
20
o
cl
ci
1 os
cl
ci
2 os
cl
ci
4 os
cl
10 ci
8 os
9 cl
ci os
Corrente de Curto Circuito (Kiloamperes)
8
16 cl
7 ci os
3 0 cl
6 ci os
6 0 cl
5 ci
0
10
4
1
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
4
16
10
25
35
240
150
500
630
800
1000
2,5
185
300
50
95
400
1,5
70
120
0.1
1
5
3
2
9
7
8
60
100
250
30
80
40
900
600
200
700
20
18
Novo conceito de dimensionamento de cabos com seção econômica
A NBR 5410 dimensiona os condutores pelo critério da menor seção permissível (seção de segurança e com menor
custo de aquisição) e não pelo menor custo operacional em um determinado período.
O IEC - International Electrical Commite - sugere a adoção de uma nova forma de dimensionamento para definir não
só a menor seção permissível (seção de segurança), mas também a seção com o menor custo operacional (seção
econômica).
O procedimento é bastante simples e consiste em dimensionar a seção mínima permissível (segurança) e, a partir
desta seção mínima, buscar a seção de cabo imediatamente superior e efetuar cálculos de pay back
sucessivamente.
19
DadosTécnicos
Exemplo prático
50 m
E - Cabine Primária Método G
Quadro de Distribuição Geral
QDG
70 m 50 m B - Escritório
A - Iluminação Externa Quadro de Distribuição
Método C Método B1
30 m 70 m
C - Área Fabril D - Bombeamento
Método D Método G
Seção Produto
A Tabela folha 5, método C, 3 CC 2,5 mm2 Fio / cabo antichama ou Maxvinil (70 oC)
B Tabela folha 5, método B1, 3 CC 6,0 mm2 Fio / cabo antichama ou Maxvinil (70 oC)
C Tabela folha 5, método D, 3 CC 185,0 mm 2
Cabo Maxlink ou Maxlink G flex (90 oC)
D Tabela folha 5, método G 10,0 mm 2
Fio / cabo antichama ou Maxvinil (70 oC)
20
Dimensionamento de cabos para solda
(Termoplástico 70 °C)
Definições:
Fator de Carga:
Porcentagem do Ciclo de Trabalho no qual o
cabo conduz sua corrente nominal
Ciclo de Trabalho:
por definição 5 minutos
Corrente Nominal
21
8
Qualidade, confiabilidade e tecnologia
para a produção de cabos elétricos
Maxlink G Flex Multipolar Maxlink G Flex Cabos de controle blindados com fita
0,6 / 1 kV 0,6 / 1 kV de Poliéster aluminizada
Linha de Produtos: Cabo Maxlink Antifur to 0,6/1,0 kV, Cabo Maxvinil 0,6/1,0 kV, Cabo Maxvinil Flex 0,6/1,0 kV, Os cabos fabricados de
Cabo Maxlink G-Flex 0,6/1,0 kV, Fio Sólido Antichama 750 V, Cabo Antichama 750 V, Cabo Antichama Flex 750 V, acordo com as normas
Cabo PP 750 V, Cordão Torcido 300 V, Cordão paralelo 300 V, Cabo de controle 0,6/1,0 kV, Cabo de solda. NBR 6148, NBR 13249 e
NBR 7288 são cer tificados
Fabricamos da seção 0,5 mm2 a 240 mm2 pelo INMETRO
Eletro Metalúrgica Ciafundi Ltda. - Rodovia Wilquem Manoel Neves, km 3,5 - CEP 15400-000 - Olímpia, SP
www.condumax.com.br - condumax@condumax.com.br - Fone: (17) 3279.3701 - Fax: (17) 3279.3716