Escolar Documentos
Profissional Documentos
Cultura Documentos
ENGENHARIA MECÂNICA
CURITIBA
2020
LUÍS HENRIQUE DA SILVA RODRIGUES
PAULO AUGUSTO KANIA DE OLIVEIRA
CURITIBA
2020
AGRACECIMENTOS
The use of prostheses has helped a large number of people to restore the impaired
functionality of a limb, whether due to congenital disabilities or in cases where the
need for amputation occurs, caused by illness or injury, such as work and traffic ac-
cidents . This work presents the prototype of the mechanical prosthesis and aesthet-
ics of the hallux (big toe), using an osseointegration system, with dimensions and
mechanical movements corresponding to the original limb, through the analysis of
biomaterials the titanium alloys are better accepted and were used in elaboration of
the intrameludar pin, external adapter and other components of the prototype.
Among the lower limbs, the foot is of great relevance in the gait and balance cycle so
that these activities are performed correctly, it is necessary to use the hallux limb,
which together with the other bones of the foot perform these functions. The method-
ology used in this study initially relied on physiological analysis of the limb to learn
about its functions and employ the best prosthetic method. Analysis of the materials
was of paramount importance for identifying the material to be used, given that it
needs to have biocompatibility and meet mechanical requirements. 3D modeling was
developed with reference to the healthy member of the user, through the model cal-
culations and simulations were performed via software in order to prove the function-
ality and resistance of the prototype.
1 INTRODUÇÃO ................................................................................................... 12
1.1 Objetivos gerais ........................................................................................ 14
1.2 Objetivos específicos ................................................................................ 14
2 REVISÃO DE LITERATURA .............................................................................. 15
2.1 Ciclo da marcha ........................................................................................ 15
2.2 Estrutura óssea do pé ............................................................................... 17
2.3 Biomecânica do pé ................................................................................... 17
2.4 Ângulos de extensão ................................................................................ 19
2.5 Amputação ................................................................................................ 21
2.6 Origem das amputações ........................................................................... 22
2.7 Níveis de amputação ................................................................................ 23
2.8 Próteses .................................................................................................... 25
2.9 Osseointegração ....................................................................................... 25
2.9.1 Biomateriais ........................................................................................... 27
2.9.2 Biocompatibilidade................................................................................. 28
2.9.3 Biofuncionalidade .................................................................................. 28
2.10 Aplicação de molas e funcionalidades ...................................................... 28
2.10.1 Molas de tração .................................................................................. 29
2.10.2 Mola de compressão .......................................................................... 30
2.10.3 Mola de torção .................................................................................... 31
2.11 Resistência dos materiais ......................................................................... 31
2.11.1 Curva tensão-deformação .................................................................. 32
2.11.2 Análise de elementos finitos ............................................................... 34
2.12 Processo de desenvolvimento de produto ................................................ 36
2.12.1 Processo de desenvolvimento de produto para prótese..................... 38
2.13 Pesquisa tecnológica ................................................................................ 38
3 MATERIAIS E MÉTODOS .................................................................................. 40
3.2 Projeto Conceitual ..................................................................................... 41
3.3 Projeto preliminar ...................................................................................... 42
3.4 Projeto Detalhado ..................................................................................... 43
3.4.1 Modelagem 3D ...................................................................................... 43
3.4.3 Simulações ............................................................................................ 46
4 RESULTADO E DISCUSSÃO ............................................................................ 48
4.1 PROJETO PRELIMINAR .......................................................................... 48
4.1.1 Suposição de dimensionamento ............................................................ 48
4.1.2 Cálculos iniciais ..................................................................................... 49
4.2 Projeto detalhado ...................................................................................... 54
4.2.1 Modelamento 3D ................................................................................... 54
4.2.2 Simulação .............................................................................................. 57
5 CONCLUSÃO ..................................................................................................... 64
REFERÊNCIAS BIBLIOGRÁFICAS ......................................................................... 66
ANEXO A – Seleção de materiais ........................................................................... 71
ANEXO B – Desenho técnico ................................................................................. 75
12
1 INTRODUÇÃO
1
Sinal elétrico proveniente da contração muscular.
13
2
Denominação médica para dedos dos pés.
14
2 REVISÃO DE LITERATURA
2.3 Biomecânica do pé
duas forças é gerada a força resultante que está atuando sob a cabeça do
metatarso com um ângulo de 48˚ com o eixo das abcissas (R).
2.5 Amputação
2.8 Próteses
2.9 Osseointegração
2.9.1 Biomateriais
2.9.2 Biocompatibilidade
2.9.3 Biofuncionalidade
Sendo,
𝜎 a tensão (Pa ou N/m²);
F a força aplicada (N);
A a área do plano (m²).
𝜀 é a deformação (%);
∆L é a variação de comprimento (m);
L0 é o comprimento inicial (m).
Sendo,
E o módulo de elasticidade (N/m²);
𝜀 é a deformação;
𝜎 é a tensão (N/m²).
3 MATERIAIS E MÉTODOS
3.4.1 Modelagem 3D
Cada componente por sua vez, tem sua particularidade no que se refere
a seus requisitos. Segue abaixo a lista de requisitos selecionados para cada
componente do protótipo:
-Resistência à oxidação;
46
3.4.3 Simulações
Geração da malha
A malha será gerada conforme a necessidade e complexidade do objeto
de estudo, a qualidade e a subdivisão serão importantes na forma de
prosseguir o estudo e analise dos resultados.
Formato da malha
A malha pode ser dividida em diversos formatos, se destacando entre
eles o formato triangular, tetraédrico, quadrilátero e hexaédrico
(OWEN,1998).
Como exemplo desses formatos, a Figura 20 mostra como são esses
elementos.
Fonte: Universidade Federal do Pará. Método elementos finitos. Remo Magalhães, 2003
Sendo,
u é o vetor de deslocamento.
4 RESULTADO E DISCUSSÃO
É possível nesta etapa prever alguns dos esforços que a prótese deverá
suportar, tais como compressão causada pelo movimento de pisar, a tração no
momento que o usuário levanta o membro do chão e cargas dinâmicas ao
longo do eixo.
155∗𝐹𝑒 2/3
Af =( ) (5)
𝜎𝑒
Sendo,
E,
155
FS = (6)
√Af
Sendo,
FS o fator de segurança.
155∗𝐹𝑒
𝜎𝑒 = (7)
Af 3/2
51
Sendo,
Para o protótipo são utilizadas duas molas de torção, onde suas hastes
são fixadas entre a cabeça do hálux e o adaptador externo, simulando os
movimentos de extensão do membro natural.
D
C= (8)
d
Sendo,
C o índice de mola;
4.C−C−1
K= (9)
4.C2 −4.C
Sendo,
K a constante de mola;
C o índice de mola.
32.M
σ=K (10)
π.d3
Sendo,
M = F. r. cosα (11)
Sendo,
4.2.1 Modelamento 3D
4.2.2 Simulação
σ𝑟
FS = (12)
σ𝑎
Sendo,
FS o fator de segurança;
5 CONCLUSÃO
REFERÊNCIAS BIBLIOGRÁFICAS
ABRANTES, Bianca Ferreira. Design de prótese de pododáctilo: a
personalização como ferramenta para autoafirmação. 2019. TCC. Curso de
Design. Universidade Federal da Paraíba. Rio Tinto – PB. Acesso em 03 de
março de 2020. Disponível em:
https://repositorio.ufpb.br/jspui/handle/123456789/16269;
HIBBELER, R.C. Resistência dos Materiais, 3.º Ed., Editora Livros Técnicos e
Científicos, 2000;
KINZEL, G.L., HALL, A.S., Jr., and HILLBERRY, B.M.: Measurement of the
total motion between two body segments. I. Analytical development. J.
Biomech., 5:93-105,1972;
NEVIN, Craig. The design and cadaveric assessment of a new artificial first
metatarsophalangeal joint replacement for the great toe. 1995. Tese de
mestrado em Engenharia biomédica. Universidade da Cidade do Cabo (UCT);
Tabela com propriedades do parafuso métrico sem cabeça com sextavado interno retirado do
PROVENZA, 1960.
74
Mola – peça 5.