In the present work is made a design analysis of shoring systems to the ground
and a study of bracing systems efficiency. By definition, shore is a structure of
temporary support that transmits formwork load, reinforced concrete load and
constructions loads to the ground or a low storey.
The different types of shoring systems in Portugal are described and the
materials used on these systems are presented. Some design procedures
based on European temporary structures code, EN 12812, are studied and his
clauses are considered in a numerical model, giving special attention on two
relevant aspects: structural stability (bracing systems) and buckling. The safety
rules in construction site are described.
NDICE
1
INTRODUO ...................................................................................................................................... 1
1.1 GENERALIDADES ................................................................................................................................. 1
1.2 ESTRUTURAS TEMPORRIAS E ESTRUTURAS DEFINITIVAS .................................................................. 1
1.3 CIMBRES E ANDAIMES ......................................................................................................................... 3
Generalidades ............................................................................................................................ 7
2.3.2
Ao .......................................................................................................................................... 10
2.3.3
Alumnio .................................................................................................................................. 11
3.2.2
3.2.3
3.3.2
Generalidades .......................................................................................................................... 23
3.4.2
3.4.3
3.6.2
3.6.3
3.6.3.1 Generalidades..................................................................................................................................... 41
3.6.3.2 Deslizamento Global .......................................................................................................................... 41
3.6.3.3 Deslizamento Local ............................................................................................................................ 42
3.6.3.4 Derrubamento..................................................................................................................................... 44
3.6.3.5 Suco ................................................................................................................................................ 44
3.7.2
3.7.3
3.7.3.1 Generalidades..................................................................................................................................... 49
3.7.3.2 Imperfeies para anlise global de bastidores ................................................................................. 50
3.7.3.3 Imperfeio para anlise de sistemas contraventados........................................................................ 54
3.7.3.4 Imperfeies dos elementos individuais .............................................................................................. 56
3.7.4
3.8.2
3.8.2.1 Generalidades..................................................................................................................................... 63
3.8.2.2 Distribuio das aces ...................................................................................................................... 64
3.8.2.3 Especificaes de Dimensionamento .................................................................................................. 64
3.8.2.3.1
3.8.2.3.2
3.8.2.4.2
3.8.2.4.3
3.8.2.5.2
ii
4.3.1
4.3.2
4.3.3
SEGURANA ...................................................................................................................................... 93
5.1 GENERALIDADES ............................................................................................................................... 93
5.2 REGRAS GERAIS DE SEGURANA ....................................................................................................... 93
5.3 CONCLUSES PARCIAIS ...................................................................................................................... 94
CONCLUSES .................................................................................................................................... 95
APNDICE .................................................................................................................................................... 99
A.1.
A.2.
iii
NDICE DE FIGURAS
Figura 1 Cobertura provisria na Igreja Matriz de Caminha [3] ..................................................................... 2
Figura 2 Cofragem vertical [4] ........................................................................................................................ 2
Figura 3 Sistema de cimbres utilizado no viaduto do Seda e Chocanal IC3 [4].............................................. 3
Figura 4 Andaime de Quadro de acordo com a norma EN 12811 [6] ............................................................. 4
Figura 5 Escoramento com sistema de cimbres Doka no viaduto da Nova Ponte do Carregado .................... 5
Figura 6 Viga de lanamento na Ponte do Montijo [7] ................................................................................... 5
Figura 7 Carros de avano na Ponte Octavio Frias de Oliveira em So Paulo [8] .......................................... 6
Figura 8 Escoramento de lajes a grande altitude com sistema de cimbres Doka: Expo Zaragoza 2008 ......... 6
Figura 9 Lajes com prumos de ps-escoramento [10]..................................................................................... 7
Figura 10 Prumos em madeira ........................................................................................................................ 8
Figura 11 Prumos extensveis em alumnio [4] ............................................................................................... 8
Figura 12 Prumos extensveis em ao ............................................................................................................. 8
Figura 13 GFRP: perfis pultrudidos de fibra de vidro [13] ............................................................................. 9
Figura 14 Prumo em ao [15]........................................................................................................................ 10
Figura 15 Prumo em ao com trip [16] ....................................................................................................... 10
Figura 16 Sistema de cimbres em torre em ao [15] ..................................................................................... 11
Figura 17 Sistema de cimbres modular em ao [15] ..................................................................................... 11
Figura 18 Prumo em alumnio [15] ............................................................................................................... 12
Figura 19 Sistema de cimbres em alumnio [15] ........................................................................................... 12
Figura 20 Prumos extensveis de diferentes comprimentos [12] ................................................................... 14
Figura 21 Prumo em alumnio de alta capacidade [4] ................................................................................... 14
Figura 22 Bastidores com elementos diagonais de contraventamento [15] .................................................. 15
Figura 23 Sistema de cimbres modular: variao do espaamento com a altura [15] ................................... 15
Figura 24 Colapso de sistema de cimbres [19].............................................................................................. 17
Figura 25 Exemplos de elementos de suporte sobrepostos [1]...................................................................... 22
Figura 26 Lastros colocados no sistema de cimbres [21] .............................................................................. 25
Figura 27 Sobrecarga do beto na cofragem [1] ........................................................................................... 26
Figura 28 Zonamento de Portugal continental para caracterizao da aco ssmica [23] ........................... 27
Figura 29 Espectros de resposta para a zona A e para um terreno tipo I [23] ............................................... 28
Figura 30 - Espectros de resposta para a zona A e para um terreno tipo II [23] .............................................. 29
Figura 31 - Espectros de resposta para a zona A e para um terreno tipo III [23] ............................................. 30
Figura 32 Deformaes relativas resultantes de assentamentos de apoio ou variao da temperatura [1] .... 32
Figura 33 Curva genrica tempo - assentamento de uma fundao [24]....................................................... 33
Figura 34 Carregamento de um macio estratificado e elstico [24] ............................................................ 35
Figura 35 Flecha mxima para os elementos individuais [2] ........................................................................ 41
Figura 36 Atrito de resistncia contra o deslizamento [1] ............................................................................. 42
iv
vi
NDICE DE TABELAS
Tabela 1 Vantagens e desvantagens do GFRP: perfis pultrudidos de fibra de vidro [14] .............................. 9
Tabela 2 Influncia do assentamento imediato consoante a natureza do solo [24] ...................................... 34
Tabela 3 Valores mdios de Is para macios semi-indefinidos [24] ............................................................. 34
Tabela 4 Factores de combinao de aces [1] ....................................................................................... 36
Tabela 5 Combinaes de aces para os vrios casos de carga: E.L.U. ..................................................... 38
Tabela 6 Combinaes de aces para os vrios casos de carga: E.L.S. ...................................................... 40
Tabela 7 Factores de aces parciais, i, para a estabilidade do corpo rgido [1] ......................................... 41
Tabela 8 Coeficientes de atrito, , para vrias combinaes de materiais [1] .............................................. 43
Tabela 9 Valores de dimensionamento da imperfeio resultante de ns fixos inicial e0/L [25].................. 51
Tabela 10 Factores de imperfeio para curvas de encurvadura [25] ........................................................... 58
Tabela 11 Seleco da curva de encurvadura consoante a seco transversal [25] ...................................... 59
Tabela 12 Formas de deslocamento para ligaes em madeira [1]............................................................... 70
Tabela 13 Resultados da anlise das geometrias de contraventamento: A ................................................... 79
Tabela 14 Resultados da anlise das geometrias de contraventamento: B ................................................... 81
Tabela 15 Resumo das aces a considerar para o modelo de elementos finitos ......................................... 82
Tabela 16 Combinaes de aces para os vrios casos de carga da modelao: E.L.U.............................. 84
Tabela 17 Combinaes de aces para os vrios casos de carga da modelao: E.L.S. ............................. 85
Tabela 18 Variao do deslocamento global da estrutura com o n de planos contraventados .................... 87
Tabela 19 Esforo axial mximo, Nmax, dos elementos e deslocamento global mximo, max, da estrutura 89
Tabela 20 Verificao ao esforo axial: E.L.U............................................................................................. 90
Tabela 21 Verificao encurvadura: E.L.U. .............................................................................................. 90
Tabela 22 Verificao deformao: E.L.S. ................................................................................................ 90
Tabela 23 Coeficientes de presso recomendados,
vii
Introduo
1 Introduo
1.1 Generalidades
Os cimbres so estruturas de suporte onde a cofragem vai apoiar. Estas estruturas,
consideradas temporrias ou provisrias, necessitam de ser dimensionadas para cumprirem as
funes para as quais foram projectadas em segurana.
H uma grande necessidade de explorar este tema, visto que, apesar de ter sido elaborada
uma Norma Europeia, EN 12812 [1], relativa ao dimensionamento de estruturas temporrias de
construo, as empresas que actuam no mercado portugus ainda no adoptaram por completo as
disposies desta norma. Devido ao facto das empresas no serem portuguesas continuam a adoptar
a legislao referente ao pas de origem, utilizando por vezes, critrios prprios para dimensionar
os sistemas de cimbres de que dispem.
Surgiu ento a necessidade de pesquisar a regulamentao existente sobre o assunto,
especialmente aquela que usada pelas empresas; fazer uma anlise e tentar uniformizar o clculo
efectuado para o dimensionamento; verificar se os coeficientes de segurana aplicados nas diversas
situaes so os mais adequados.
O presente estudo organiza-se em 4 captulos: sistemas de cimbres, dimensionamento de
cimbres, modulao computacional de cimbres ao solo e segurana. No captulo de sistemas de
cimbres realizada uma apresentao de todos os tipos de sistemas e dos materiais utilizados para
cimbres. No segundo captulo feita uma anlise de todos os procedimentos de dimensionamento
baseados na EN 12812. O captulo seguinte consiste na aplicao desses procedimentos a uma torre
de cimbres ao solo com anlise prvia do contraventamento mais eficaz. O ltimo captulo incide
nas regras e procedimentos de segurana na fase de execuo.
Introduo
os tipos de estruturas requerem planeamento e uma anlise rigorosa, tanto na fase de projecto como
na fase de execuo. Neste estudo focar-se- a anlise e planeamento das estruturas temporrias.
Segundo a EN 12812 e a DIN 4421, [2], as estruturas temporrias consistem em estruturas
que so montadas no local de construo constitudas por elementos individuais, que podero ser
desmontadas posteriormente. De acordo com as duas normas, estas estruturas so utilizadas para:
Introduo
Introduo
Para esclarecer a diferena entre estes dois tipos de estruturas temporrias importante
colocar-se a questo: para que que esta estrutura utilizada?. Se a plataforma tem uma funo
estrutural suportando cargas denomina-se de cimbres. incorrecto assumir que desde que o
trabalhador esteja neste ltimo tipo de plataforma, por exemplo, a colocar a armadura para o beto
armado, seja denominada de andaimes e, portanto, aplicar as normas dos andaimes. As diferenas
entre normas e regulamentos de ambas as estruturas so evidentes. Por exemplo, no caso dos
E.U.A., o factor de segurana para andaimes , segundo o Scaffolding, Shoring and Forming
Institute, Inc, de 4 e varia entre 2 e 4 para os cimbres. Os requisitos de proteco anti-queda, acesso
e capacidade resistente para ambas as estruturas esto definidos em diferentes anexos da norma
federal da OSHA (United States Federal Occupational Safety and Health). Os fabricantes destes
elementos estabelecem diferentes procedimentos de dimensionamento para cada.
Quando a obra no exige sistemas de cimbres mais complexos, o seu dimensionamento
pode ser realizado pela prpria empresa de construo ou empreiteiro responsvel pela obra.
Contudo, em obras de maior volume ou de carcter especial este estudo pode ser encomendado a
empresas especializadas neste tipo de projectos. Estas empresas apoiam-se em normas e
regulamentos que podem ser do pas de origem da empresa, do pas em que est a ser implantada a
obra e at por regulamentos internos empresa que se baseiam na sua experincia.
Sistemas de Cimbres
2 Sistemas de Cimbres
2.1 Generalidades
A abordagem aos sistemas de cimbres vai ser feita com base nalguns sistemas utilizados
por empresas que operam a nvel mundial incluindo o territrio portugus. Algumas das principais
empresas que actuam no mercado portugus (por exemplo a PERI, Doka e Ulma) possuem os seus
prprios sistemas, alguns deles testados nos seus prprios laboratrios de ensaios e homologados
por entidades competentes. Estas empresas utilizam nica e exclusivamente como materiais para
cimbres o ao e o alumnio. Neste captulo so descritos estes sistemas, sendo que nem todos so
utilizados em Portugal.
Existem diferentes tipos de sistemas de cimbres. A sua escolha depende do tipo e das
exigncias da construo a das caractersticas de cada sistema, tais como, o material de que
constitudo, a altura mxima e a capacidade resistente.
Os sistemas de cimbres so utilizados para realizar o escoramento de tabuleiros de pontes,
viadutos, passagens superiores e inferiores atravs de cimbre ao solo (ver Figura 5), vigas de
lanamento, Figura 6, e carros de avano, Figura 7. Os cimbres so tambm usados para suportar
lajes de edifcios a grande altura (ver Figura 8).
Sistemas de Cimbres
Sistemas de Cimbres
O ps-escoramento pode ser feito de duas maneiras, prumo a prumo que consiste em
colocar prumos em toda a rea da laje ou do elemento em construo; ou atravs de uma anlise
rigorosa deste tipo de escoramento em locais especficos [11]. A abordagem mais conservativa a
primeira.
Pr-escoramento utilizado quando a cofragem removida antes de o beto atingir a
resistncia para se suportar a ele prprio [11]. Suportes verticais so colocados atravs da cofragem
enquanto esta ltima removida. O pr-escoramento utilizado para suportar beto fresco, que
ainda no atingiu a resistncia pretendida. O ps-escoramento usado para transferir cargas do
escoramento e/ou pr-escoramento para a estrutura inferior evitando deformaes excessivas.
A partir do momento em que o equipamento utilizado para o escoramento, psescoramento e pr-escoramento o mesmo, no existe nenhum mtodo para reconhecer os
diferentes propsitos em obra. o tipo de utilizao do equipamento que identifica a sua funo.
2.3 Materiais
2.3.1
Generalidades
No sculo XX, quando surgiu o beto armado, os cimbres ento utilizados eram de
madeira. Este material, considerado de baixo custo, foi utilizado durante grande parte desse sculo.
Apenas nos finais do sculo XX se comearam a utilizar o ao e o alumnio. Todavia, no continente
asitico e em algumas construes em Portugal, continua-se a utilizar no s a madeira mas
tambm o bambu para efectuar o escoramento das construes. A escolha do material a utilizar
Regras para o dimensionamento de cimbres em estruturas de beto armado
Sistemas de Cimbres
deve ser feita com base numa combinao de variveis: preo, segurana durante a obra e
qualidade pretendida para o produto final.
Apesar de se verificar o uso de prumos de madeira em algumas obras de pequena
dimenso, Figura 10, a madeira comea a desaparecer definitivamente num mercado onde o ao e o
alumnio so os mais utilizados.
Sistemas de Cimbres
Outro material que poderia ser aplicado neste tipo de estruturas seria o FRP Fiber
Reinforced Polymer (perfis pultrudidos de fibra). Este material, que poder ser de fibra de vidro,
carbono ou aramida, no utilizado nas estruturas temporrias, contudo, rene caractersticas que o
tornam capaz de desempenhar a funo de suporte. O GFRP (ver Figura 13) comeou a ser
desenvolvido por volta de 1935, [13], e, at aos dias de hoje, tem vindo a ser reconhecido como um
material capaz de substituir o ao em alguns casos de construes definitivas.
Os materiais compsitos tm vindo a ser cada vez mais utilizados em muitas aplicaes na
indstria civil, marinha e aeroespacial, [13]. At agora, os perfis pultrudidos de fibra de vidro
surgem como uma alternativa forte a outros materiais devido s suas vantagens relativamente aos
mesmos (ver Tabela 1).
No entanto, este material compsito tambm rene alguns aspectos desfavorveis sua
utilizao. Na Tabela 1 esto descritas algumas vantagens e desvantagens deste material.
Tabela 1 Vantagens e desvantagens do GFRP: perfis pultrudidos de fibra de vidro [14]
VANTAGENS
DESVANTAGENS
Resistncia corroso;
Resistncia ao desgaste;
Manuteno reduzida;
Material leve.
Sistemas de Cimbres
2.3.2
Ao
10
Sistemas de Cimbres
2.3.3
Alumnio
Os sistemas de cimbres em alumnio so pouco utilizados em Portugal uma vez que este
material mais dispendioso que o ao e a sua capacidade resistente semelhante a este. Este tipo
de sistemas utilizado em construes especiais e a sua vantagem relativamente aos sistemas em
11
Sistemas de Cimbres
ao a sua leveza. Na Figura 18 e na Figura 19, esto representados alguns exemplos destes
sistemas.
12
Sistemas de Cimbres
Prumos;
Estes sistemas vo variar nas suas caractersticas que envolvem o material que os constitui,
a altura mxima admissvel e a capacidade resistente. Os prumos, elementos verticais
independentes extensveis (Figura 20), em ao podero atingir alturas at 5,0 m e ter uma
capacidade resistente at 40 kN por prumo. A capacidade resistente no se verifica na altura
mxima porque medida que se aumenta o comprimento do prumo, diminui a capacidade
resistente devido encurvadura. Portanto, a resistncia do prumo altura pretendida e as aces
que solicitam o sistema vo definir o nmero de prumos por metro quadrado que sero necessrios
montar. Os prumos em alumnio possuem sensivelmente a mesma resistncia para alturas
semelhantes. O prumo essencialmente utilizado para realizar o escoramento, pr-escoramento e
ps-escoramento de lajes.
Existem prumos de alta capacidade resistente que suportam cargas at 200 kN. Estes
prumos, em alumnio (Figura 21), so constitudos por mdulos, o que lhes permite serem
extensveis e adequarem-se altura de suporte pretendida.
13
Sistemas de Cimbres
14
Sistemas de Cimbres
Os sistemas de cimbres modulares consistem num escoramento por filas de bastidores onde
o espaamento entre estas vai depender da altura do sistema, como se pode verificar na Figura 23.
Estes sistemas podero atingir alturas superiores a 20 m com uma capacidade resistente de 40 kN
por cada elemento vertical (ver Figura 17).
Contudo, se o mesmo sistema de cimbres modular for constitudo por alumnio (ver Figura
19) poder, para uma altura de 20 m, possuir uma capacidade resistente de 90 kN por cada
15
Sistemas de Cimbres
elemento vertical. Verifica-se que o alumnio possui maior capacidade resistente que o ao,
suportando mais carga por metro quadrado.
16
Dimensionamento de Cimbres
3 Dimensionamento de Cimbres
3.1 Generalidades
Os aspectos a considerar no dimensionamento de cimbres, segundo a ACI 347-01 [17] e a
EN 12812, so: a estabilidade do sistema e a encurvadura dos elementos [5], para evitar o colapso
da estrutura, como se pode ver representado na Figura 24. Os cimbres devem ser dimensionados
para suportar todas as aces que lhes so transmitidas. Deve ser adoptada uma anlise rigorosa
para determinar o nmero de lajes que devem ser escoradas e para determinar as aces que vo ser
transmitidas a cada laje e aos cimbres.
Os aspectos e parmetros a considerar pela ACI 347-01 para uma correcta anlise de
dimensionamento so os seguintes:
17
Dimensionamento de Cimbres
Na altura da colocao do beto, desmontagem da cofragem, do ps-escoramento e do prescoramento, o vo da laje ou elemento estrutural entre suportes permanentes tambm no
deve ser ignorado assim como os tipos de sistemas de cofragem, isto , vo dos
componentes horizontais da cofragem e cargas dos cimbres individuais;
Para este grupo de estruturas os desenhos podem ser dispensados. A estabilidade dever ser
verificada caso o projectista no possua a experincia necessria. Neste caso, a estabilidade deve
ser verificada com a considerao de um factor de segurana de 1,25.
18
Dimensionamento de Cimbres
Peas escritas
Na fase de projecto dos sistemas de cimbres, a norma EN 12812, obriga a que seja
elaborado um documento com informao escrita sobre os clculos, de modo a que se informe de
todas as hipteses assumidas, parmetros considerados e modelo adoptado. Nesta memria
definido o dimensionamento estrutural que deve incluir os seguintes elementos:
A classe de dimensionamento;
Montagem;
Betonagem/sequncia de betonagem;
Desmontagem;
A descrio do modelo adoptado para a anlise estrutural, com uma nota para todas as
consideraes tomadas;
19
Dimensionamento de Cimbres
3.2.2
Peas desenhadas
As peas desenhadas ou desenhos, para estruturas de classe B1, devero ser fornecidos com
detalhes completos dos trabalhos de construo permanentes.
Por seu lado, os desenhos das estruturas de classe B2, devero descrever os componentes
dos sistemas de cimbres em planta, alados e cortes, de modo a que, no mnimo, os seguintes
elementos estejam representados:
Necessidades locais particulares para fins especiais, como o acesso a veculos e todas
as desobstrues necessrias;
3.2.3
A adicionar s peas escritas e desenhadas dever ser fornecida informao para o local de
construo, onde, pelo menos, dever seguir para obra os elementos seguintes:
Desenhos;
20
Dimensionamento de Cimbres
Exigncias globais
A estrutura de cimbres dever ser dimensionada para resistir a todas as aces a que poder
estar sujeita, transmitindo os esforos da provenientes para o solo ou para uma estrutura capaz de
os resistir. As tcnicas de montagem de cimbres e as condies ambientais devero ser tidas em
conta no dimensionamento. Devero ser tomadas precaues relativas aos meios de acesso para
montagem, utilizao e desmontagem do cimbre. Devero ser seguidas as disposies da EN
12811-1. O dimensionamento dever basear-se em conceitos e detalhes de realizao viveis e de
fcil compreenso para serem verificados no local de construo. Todos os alinhamentos
horizontais devero estar contraventados desde a base at ao topo da estrutura.
3.3.2
Exigncias especficas
21
Dimensionamento de Cimbres
Se a estrutura temporria for suportada por uma estrutura definitiva, dever ser verificado
que esta ltima possui capacidade resistente para suportar as cargas que iro ser aplicadas. Quando
o apoio da estrutura consiste em elementos de madeira rectangulares horizontais ou outros
elementos similares sobrepostos, como se pode observar na Figura 25, poder ter que se verificar a
estabilidade lateral, se se verificar um dos seguintes casos:
Dois elementos so colocados um sobre o outro com as arestas mais compridas paralelas
(ver Figura 25);
a) suporte cruzado
b) elementos sobrepostos
c)
22
Dimensionamento de Cimbres
3.4 Aces
3.4.1
Generalidades
23
Dimensionamento de Cimbres
3.4.2
Aces Directas
Segundo a norma, as aces directas englobam cinco tipos, que a seguir se descrevem:
Aces permanentes;
Aco do vento;
Efeitos ssmicos.
3.4.2.1
Aces permanentes
Estas cargas, designadas por Q1, actuam durante o tempo de vida til da estrutura de
24
Dimensionamento de Cimbres
3.4.2.2
25
Dimensionamento de Cimbres
3.4.2.3
igual a 10 % do peso prprio do beto, no devendo ser inferior a 0,75 kN/m2 e superior a 1,75
kN/m2, numa rea de 3 x 3 m. Esta sobrecarga resulta do facto de o beto fresco no se espalhar
uniformemente pela cofragem na altura da betonagem, como exemplifica a Figura 27.
3.4.2.4
Aco do vento
A norma define dois valores para esta aco. Dever ser considerado um valor para o vento
mximo, Q5, e um valor para o vento de trabalho, Q6. A EN 1991-1-4 fornece informao acerca do
valor do vento mximo, nomeadamente da presso de velocidade para um perodo de retorno de 50
anos, [22]. A presso de velocidade poder ser reduzida, sendo multiplicada por um factor no
inferior a 0,7, quando o perodo de utilizao dos sistemas de cimbres inferior a 24 meses. Para o
vento de trabalho, a norma fixa o valor de 0,20 kN/m2, que corresponde a uma velocidade de 65
km/h [1].
3.4.2.5
Efeitos ssmicos
A norma EN 12812 define que devero ser impostos limites aos efeitos ssmicos, Q7, de
acordo com a ENV 1998 com especial ateno aos regulamentos nacionais relativos aco
ssmica. O regulamento portugus que possui normativas neste mbito o R.S.A., Regulamento de
Segurana e Aces, [23].
A quantificao desta aco vai depender da localizao da construo e, por esse motivo,
o regulamento divide o pas em 4 zonas (A,B,C e D), Figura 28. necessrio considerar para esta
26
Dimensionamento de Cimbres
aco a variabilidade da sua durao e do seu contedo em frequncias, que vo depender para uma
mesma intensidade de aco ssmica, dos valores da magnitude e da distncia focal. No entanto,
ser suficiente verificar a segurana das estruturas em apenas dois casos de aco ssmica:
Aco ssmica que represente um sismo de magnitude moderada a pequena distncia focal
(aco ssmica tipo 1);
Aco ssmica que represente um sismo de maior magnitude a uma maior distncia focal
(aco ssmica tipo 2).
27
Dimensionamento de Cimbres
Tipo II: solos coerentes muito duros, duros e de consistncia mdia ou solos incoerentes
compactos;
Tipo III: solos coerentes moles e muito moles ou solos incoerentes soltos.
28
Dimensionamento de Cimbres
29
Dimensionamento de Cimbres
Figura 31 - Espectros de resposta para a zona A e para um terreno tipo III [23]
A resposta correspondente a cada modo de vibrao poder ser obtida atravs de uma
ponderao quadrtica, efectuada por meio de uma raiz quadrada da soma dos quadrados da
resposta devida a cada um dos espectros pelos quais quantificada a aco ssmica. Por sua vez, a
resposta global da estrutura poder ser estimada atravs de uma ponderao anloga das respostas
correspondentes a cada modo de vibrao.
De um modo simplificado a aco ssmica poder ser representada por uma fora
equivalente nas duas direces ortogonais a aplicar na estrutura. Atravs da modelao
computacional da estrutura retira-se a frequncia de resposta relativa ao 1 modo. Com esta
frequncia e com o auxlio dos grficos anteriores retira-se a acelerao. Esta acelerao vai indicar
a influncia de todas as aces verticais aplicadas na estrutura na componente horizontal da fora
equivalente em percentagem. A componente vertical corresponde a um tero da componente
horizontal. Para retirar a acelerao atravs da frequncia necessrio conhecer o coeficiente de
amortecimento da estrutura que depende da capacidade do material e das ligaes de dissiparem
energia.
30
Dimensionamento de Cimbres
3.4.3
Aces Indirectas
Como j foi referido anteriormente, as aces indirectas, Q8, tm que ver com as condies
Variao da temperatura;
Assentamentos de apoio;
Para estruturas de classe B1, os efeitos de assentamento de apoio devem ser considerados
em todos os casos. Para estruturas de classe B2, os efeitos devem ser tidos em conta com excepo
dos seguintes pontos:
31
Dimensionamento de Cimbres
3.2
Onde:
Rd o valor de clculo da resistncia normal;
Rd* o valor de clculo da resistncia depois de ter ocorrido assentamento de apoio e
variao trmica;
h a altura global da estrutura;
l o comprimento horizontal da estrutura;
s o assentamento de apoio;
t o deslocamento horizontal provocado pela variao de temperatura.
a)
Sistema terico
b)
Assentamento de apoio
c)
Variao da temperatura
Esta exigncia de flexibilidade tem como objectivo permitir que as estruturas possam ser
utilizadas nas condies do local de construo.
Existindo um limite mximo para os assentamentos de apoio torna-se necessrio calcular os
deslocamentos verticais descendentes consequentes das aces verticais que solicitam a estrutura
de suporte temporrio. O assentamento total, s, a soma de trs componentes: o assentamento
32
Dimensionamento de Cimbres
imediato, si, o assentamento por consolidao, sc, e o assentamento por consolidao secundria ou
por fluncia, sd [24], equao 3.3:
3.3
Contudo, uma vez que os assentamentos por consolidao primria e por fluncia so a
longo prazo, o assentamento de apoio total vai ser apenas influenciado pela componente de
assentamento imediato, como se pode verificar na Figura 33.
33
Dimensionamento de Cimbres
Si
Praticamente nulo
Praticamente nulo
Muito varivel
Baixo a moderado
Varivel num intervalo
relativamente lato
Varivel num intervalo
relativamente lato
O assentamento de apoio imediato para um macio (solo) constitudo por n camadas, todas
com comportamento elstico, sujeito a uma carga p uniformemente distribuda numa determinada
rea (ver Figura 34) pode ser estimado pela simplificao da aplicao da Lei de Hooke que resulta
na seguinte equao:
1
3.4
Onde:
p a carga uniformemente distribuda numa determinada rea;
B o lado menor da rea;
o coeficiente de poisson;
E o mdulo de young;
Is o nmero real funo da geometria da rea carregada e do ponto sob o qual se pretende
obter o assentamento (ver Tabela 3).
Tabela 3 Valores mdios de Is para macios semi-indefinidos [24]
34
L/B =
rectangular
Forma da sapata
Is*
1,5
1,15
2,0
1,30
3,0
1,52
5,0
1,83
2,25
10,0
* valores mdios
Dimensionamento de Cimbres
Depois de efectuada uma regresso logartmica, a evoluo do factor Is com a relao L/B
traduzida pela equao 3.5:
0,582
0,9
0,6
0,898
3.5
35
Dimensionamento de Cimbres
Caso de carga 3
Vento mximo
Caso de carga 4
Sismo a
Factores de combinao
Caso de carga 2
Vento de trabalho
Designao
Caso de carga 1
Peso prprio + vento
mximo
Aco
Aces directas
Q1
Q5
Peso prprio
Aces variveis impostas
persistentes verticais
Aces variveis impostas
persistentes horizontais
Aces variveis impostas de
curta durao
Vento mximo
Q6
Vento de trabalho
Q7
Sismo
Q2
Q3
Q4
1,0
0
1,0
0,7
1,0
1,0
0,7
1,0
1,0
0,7
Aces indirectas
Q8
a
Outras aces
0,7
Dimensionamento de Cimbres
3.6.1
3.6
Onde:
Ed o valor de dimensionamento de uma aco interna;
Rd o valor de dimensionamento da resistncia.
O valor de Ed dever ser estabelecido pelos valores de dimensionamento das aces Qd,
tomando em considerao os efeitos de segunda ordem (para a classe B2 ver 3.7.4.1).
3.7
Onde:
Qd o valor de dimensionamento da aco;
Qk,i o valor caracterstico da aco;
37
Dimensionamento de Cimbres
3.8
DESIGNAO
Caso de carga 2
1,5 0,7
1,05
1,35 1,0
1,35
Caso de carga 1
1,35 1,0
1,35
Caso de carga 3
Caso de carga 4
1,5 1,0
1,0
1,0
1,0
0,7
1,5
1,5
1,5
1,5
1,05
1,5 1,0
1,0
0,7
1,5
1,5
1,05
1,35 1,0
1,35
1,0 0,7
0,7
0,7
1,0 1,0
0,7
Por seu lado, o valor de dimensionamento da resistncia, Rd,i, para cada uma das classes B1
e B2, deve ser determinado utilizando as equaes 3.9 e 3.10 respectivamente:
1,1
3.9
1,15
1,265
3.10
38
Dimensionamento de Cimbres
Onde:
Rk o valor caracterstico da resistncia;
3.6.2
Para os Estados Limites de Servio, o factor parcial para as aces, F, dever ser tomado
igual a 1,0, logo:
3.11
39
Dimensionamento de Cimbres
DESIGNAO
Caso de carga 1
Caso de carga 2
Caso de carga 3
Caso de carga 4
1,0 1,0
1,0 1,0
1,0 0,7
0,7
1,0
1,0
1,0
0,7
0,7
1,0 1,0
1,0 1,0
1,0 1,0
1,0
0,7
1,0 0,7
0,7
0,7
0,7
0,7
500
3.12
40
Dimensionamento de Cimbres
3.6.3
3.6.3.1
Aco
Permanente Q1
Presso dos solos Q1
Outras aces
3.6.3.2
Estabilizadora
0,9
0,6
0,0
Destabilizadora
1,35
1,35
1,50
Deslizamento Global
O deslizamento global deve ser resistido por meio do atrito resultante do peso prprio, por
um equipamento mecnico ou pela combinao de ambos (ver Figura 36). Apenas quando
possvel provar que o equipamento mecnico actua conjuntamente com a resistncia proveniente do
atrito se podem considerar simultaneamente.
Regras para o dimensionamento de cimbres em estruturas de beto armado
41
Dimensionamento de Cimbres
3.13
3.6.3.3
Deslizamento Local
3.14
42
Dimensionamento de Cimbres
Onde:
Rf,d o valor de dimensionamento da resistncia contra o deslizamento paralelo ao plano
do apoio (ver Figura 36) e calculado usando a equao 3.15:
,
, ,
, ,
1,3
3.15
Onde:
Fd o valor de dimensionamento da fora paralela ao plano do apoio que conduz ao
deslizamento (ver Figura 36);
Nd fora de dimensionamento normal ao plano de deslizamento (ver Figura 36);
Rm,d,i o valor de dimensionamento da resistncia do equipamento mecnico;
Coeficiente de atrito
Mximo
Mnimo
1,0
0,4
1,0
0,6
1,2
1,0
0,8
0,4
1,0
1,0
0,5
0,8
0,2
0,3
0,5
0,5
3
4
5
6
7
8
Madeira/ao
Madeira/beto armado
Ao/ao
Ao/beto armado
Ao/argamassa
Beto armado/beto armado
43
Dimensionamento de Cimbres
3.6.3.4
Derrubamento
O derrubamento deve ser resistido pelo peso prprio, lastros, fixao mecnica ou a
combinao dos trs.
3.16
3.6.3.5
Suco
A suco, deslocamento ascendente global da estrutura, deve ser resistida pelo peso
prprio, lastros, fixao mecnica ou a combinao dos trs.
Dever ser verificado que a resistncia de dimensionamento contra a suco, Nstb, maior
do que as foras de dimensionamento que conduzem suco, Ndst (ver Tabela 7):
3.17
44
Dimensionamento de Cimbres
3.7.1
Dever ser tomado um valor mnimo de 5 mm para a excentricidade da aco nos pontos de
carregamento onde no exista equipamento de posicionamento. Onde no exista equipamento de
posicionamento a excentricidade tomada poder ser reduzida para um valor dentro dos limites dos
elementos principais. Para efeitos de clculo pode-se considerar esta excentricidade como um
deslocamento nos elementos da estrutura, 5 mm, ou como um momento flector na extremidade dos
elementos, Me, que resulta do produto entre a fora aplicada, P, e o deslocamento, como representa
a Figura 37.
5mm
Me
0,005
3.7.2
ser inferior a 2 mm. As ligaes devero ser dimensionadas de modo a que os elementos no se
separem, fazendo com que o sistema de cimbres perca a sua funo de suporte. As ligaes de
Regras para o dimensionamento de cimbres em estruturas de beto armado
45
Dimensionamento de Cimbres
elementos verticais de seces ocas sujeitos a compresso sem meios de fixao adicionais devero
ser consideradas de modo a no provocar ruptura das ligaes, isto se o comprimento de
sobreposio no for inferior a 150 mm. O comprimento de sobreposio da ligao no tubo, h0
(Figura 38), dever ser 25 % do comprimento da ligao, h1 ou 150 mm, considerando o maior dos
dois.
No caso dos prumos extensveis vamos ter imperfeies angulares uma vez que a ligao
entre o tubo interior e o exterior poder no assegurar por completo a verticalidade do prumo
(tubo), formando-se um ngulo entre o tubo superior e o eixo vertical, designando-se, portanto, por
imperfeio angular.
Por seu lado, os bastidores dos sistemas de cimbres podero sofrer desalinhamentos entre
si. Estes desalinhamentos tm origem em eventuais excentricidades nas ligaes.
3.7.2.1
Tubos
Para os tubos, as imperfeies angulares, 0, a partir da posio terica deve ser calculada
para os componentes soltos a partir das dimenses nominais. Exemplos disso so as ligaes de
extremidade e placa de base para as ligaes entre tubos.
A imperfeio angular, 0, entre dois elementos deve ser calculada utilizando a equao
3.18:
tan
1,25
3.18
Onde:
di o dimetro interior especificado do tubo, em milmetros;
d0 o dimetro exterior especificado da ligao de extremidade, em milmetros;
l0 o comprimento de sobreposio, em milmetros;
0 o ngulo, em radianos, entre os dois elementos ou componentes soltos (ver Figura 38).
46
Dimensionamento de Cimbres
Se existir mais do que uma ligao em cada eixo, o ngulo, 0, a ser utilizado para o
processo de clculo deve ser calculado utilizando a equao 3.19:
tan
0,5
tan
3.19
Onde:
nv o nmero total de tubos verticais a serem sobrepostos.
3.7.2.2
Bastidores
47
Dimensionamento de Cimbres
1,25
2
3.20
Onde:
di e d0 esto definidos no subcaptulo anterior;
e a distncia entre os eixos dos dois elementos tubulares que se unem, representado na
Figura 39.
en
, onde n o nmero de
bastidores colocados uns sobre os outros. Onde o topo est alinhado com a base, o desalinhamento
central dever valer
48
Dimensionamento de Cimbres
a)
b)
3.7.3
3.7.3.1
Encurvadura: Classe B1
Generalidades
As imperfeies para esta classe de estruturas devero ser determinadas pela EN 1993-1-1.
Na anlise estrutural deste tipo de estruturas devero ser consideradas tolerncias que representem
os efeitos das imperfeies, incluindo as tenses residuais e as imperfeies geomtricas, como por
exemplo, a falta de verticalidade e quaisquer excentricidades presentes nas ligaes da estrutura
no carregada. Devero ser utilizados valores para as imperfeies geomtricas equivalentes que
reflictam os possveis efeitos de todos os tipos de imperfeies, a no ser que estes estejam
considerados na frmula de resistncia para o dimensionamento do elemento, subcaptulo 3.7.2.
As imperfeies que devero ser tidas em conta para o dimensionamento destas estruturas
so:
49
Dimensionamento de Cimbres
3.7.3.2
3.21
Onde:
0 o valor de referncia:
200
2
3
1,0
50
Dimensionamento de Cimbres
Onde:
L o comprimento do elemento.
Os valores para
valores na Tabela 9.
Curva de encurvadura de
acordo com a Tabela 11
Anlise elstica
a0
350
300
250
200
150
Anlise plstica
1
1
1
1
1
300
250
200
250
100
51
Dimensionamento de Cimbres
Quando se efectua a anlise global para determinar as foras e momentos nas extremidades
para serem utilizados na verificao de elementos individuais, as imperfeies resultantes de ns
fixos locais podem ser ignoradas. Contudo, para bastidores sensveis a efeitos de segunda ordem as
imperfeies devidas a ns fixos dos elementos adicionalmente a imperfeies resultantes de ns
mveis globais devero ser introduzidas na anlise estrutural do bastidor para cada elemento
comprimido onde se encontrem as seguintes condies:
0,5
Onde:
NEd o valor de dimensionamento da fora de compresso;
Dimensionamento de Cimbres
53
Dimensionamento de Cimbres
mesmo sentido
sentidos opostos
3.7.3.3
500
3.23
Onde:
L o comprimento do vo do sistema de contraventamento;
0,5 1
54
Dimensionamento de Cimbres
Onde:
q a deformao interna do sistema de contraventamento devida carga q e a quaisquer
cargas calculadas na anlise de 1 ordem. Poder ser tomado igual a 0 na anlise de 2
ordem.
3.25
Onde:
MEd o momento mximo da viga;
h a altura da viga.
Nota: Quando a viga sujeita a uma compresso externa NEd dever incluir uma parte da
fora de compresso.
Nos pontos onde as vigas ou elementos comprimidos esto unidos, dever tambm ser
verificado que o sistema de contraventamento capaz de resistir fora local igual a
aplicada a esse sistema por cada viga ou elemento compresso que dividido nesse ponto, e de
transmitir esta fora para os pontos adjacentes onde a viga ou elemento compresso est travado,
ver Figura 46.
55
Dimensionamento de Cimbres
LEGENDA:
e0 imperfeio
qd fora equivalente por
unidade de comprimento
1 sistema de contraventamento
Figura 45 Fora estabilizadora equivalente [25]
LEGENDA:
1 junta
2 sistema de
contraventamento
3.7.3.4
Quando a estabilidade destes elementos tida em conta pela anlise de 2 ordem para
imperfeies de elementos compresso, e0 dever ser considerado. Para uma anlise de 2 ordem
56
Dimensionamento de Cimbres
que considere encurvadura lateral de um elemento sujeito a flexo, as imperfeies podero ser
adoptadas como ke0,d, quando e0,d a imperfeio de ns fixos equivalente do eixo mais fraco da
seco transversal considerada.
1,0
Onde:
NEd o valor da fora de compresso;
Nb,Rd a resistncia encurvadura do elemento compresso:
M1 = 1,0
Para calcular a resistncia encurvadura do elemento ser necessrio calcular o factor de
reduo para a esbelteza adimensional apropriada, , a partir da curva de encurvadura determinante
atravs da seguinte equao:
1
1,0
Onde:
0,5 1
0,2
o factor de imperfeio;
Ncr a fora crtica elstica:
57
Dimensionamento de Cimbres
3.26
Curva de encurvadura
a0
58
Dimensionamento de Cimbres
59
Dimensionamento de Cimbres
3.7.4
3.7.4.1
Encurvadura: Classe B2
Imperfeies resultantes de ns fixos para elementos compresso
Para os elementos compresso deve ser assumido uma imperfeio em arco global.
Devero ser dimensionados sistemas de estabilizao para elementos compresso para resistir ao
efeito de qualquer arco. Isto para ser somado imperfeio de um tubo, que est definido na ENV
1993-1-1. A Figura 48 ilustra as imperfeies em arco globais para um elemento compresso.
O valor para o deslocamento lateral ou desvio da linha principal, e, em milmetros, para um
elemento compresso sujeito flexo deve ser calculado utilizando a equao 3.27:
250
3.27
Onde:
l o comprimento nominal do elemento compresso, em milmetros;
r o factor de reduo e dado pela equao 3.28:
60
Dimensionamento de Cimbres
0,5
1,0
3.28
Onde:
nv o nmero de elementos estruturais apoiados e sobrepostos.
a)
b)
c)
61
Dimensionamento de Cimbres
3.7.4.2
tan
0,01
10
3.29
Onde:
h a altura total, em metros, de um elemento compresso ou torre;
A imperfeio, , deve ser normalmente considerada como uma imperfeio global, como
mostra a figura Figura 49a) e b) para um s elemento e uma torre respectivamente. Contudo, onde
os elementos compresso no so elementos contnuos, a imperfeio para cada elemento
individual, como o que se mostra na Figura 49c) de altura hi, deve tambm ser tomado em conta.
62
Dimensionamento de Cimbres
a)
Elemento individual
b)
c)
Dimensionamento classe B1
As foras internas devero ser calculadas de acordo com normas de engenharia estrutural
europeias ou de cada pas.
3.8.2
3.8.2.1
Dimensionamento classe B2
Generalidades
63
Dimensionamento de Cimbres
No clculo das foras internas, algumas simplificaes podero ser aceites, como indicado
nos subcaptulos seguintes. Devero ser usados mtodos elsticos para determinar a distribuio
das foras e deslocamentos.
3.8.2.2
Aquando do clculo das foras internas, as aces podero ser calculadas dividindo a
estrutura em subestruturas isostticas. Por exemplo, os planos de bastidores paralelos podero ser
analisados de uma forma independente. Deve ser tido em conta as condies das fronteiras entre as
subestruturas so modeladas realisticamente.
3.8.2.3
Especificaes de Dimensionamento
3.8.2.3.1
LEGENDA:
1 tubos diagonais
2 ligao
3 ligao que liga ao pilar
e definido anteriormente
64
Dimensionamento de Cimbres
3.8.2.3.2
1,5
1,5
5,0
0,2
Onde:
b a largura do elemento compresso;
a a largura ou altura da mais pequena seco do elemento de contraventamento das vigas
de asnas;
h a dimenso vertical da seco do elemento compresso;
H a distncia entre os eixos baricntricos do elemento compresso e do elemento
traco.
Para garantir estabilidade lateral quando a viga apoia na extremidade do elemento, ter que
se efectuar tambm contraventamento transverso em ambas as extremidades (ver exemplo na
Figura 52) ou outras medidas de precauo equivalentes.
65
Dimensionamento de Cimbres
LEGENDA:
1 Rigidez plana (contraventamento
horizontal)
2 Eixos do elemento de base
3 Plano a ser contraventado
4 Elemento de topo
LEGENDA:
3.8.2.4
3.8.2.4.1
cos
3.31
Onde:
E o mdulo de elasticidade dos elementos diagonais;
66
Dimensionamento de Cimbres
1
2
3.32
Onde:
m dado pela equao 3.33:
3.33
a)
contraventamento real
b) contraventamento terico
67
Dimensionamento de Cimbres
Figura 54 Explicao dos smbolos para o clculo do tubo e do ajustamento da rigidez do bastidor [1]
Onde:
bi nmero de referncia;
li distncia entre verticais adjacentes e o alinhamento vertical de bastidores;
H1 soma das foras transversais resultantes da aco externa aplicada no topo da seco
contraventada da estrutura;
H a altura global da estrutura;
Hi a distncia vertical entre sucessivos elementos horizontais;
N a aco vertical;
Ni a aco vertical no ponto i.
3.8.2.4.2
Onde existe uma linha de elementos de madeira que tenham contraventamento ligado
atravs de rtulas ou pinos de qualquer tipo, e a excentricidade, e, no n no exceder os 250 mm, a
rigidez transversal, Si, dever ser calculada utilizando a equao 3.34:
sin
1
,
cos
sin
,
3.34
68
Dimensionamento de Cimbres
Onde:
l a distncia horizontal entre um par de elementos verticais, em milmetros;
CVD e CVP so as formas do deslocamento dados na Tabela 12, que dependem do tipo e do
tamanho da ligao [
];
Ver Figura 55 para explicao dos smbolos num painel de madeira notando que neste
exemplo todas os alinhamentos de bastidores tm a mesma altura.
a) Sistema
LEGENDA:
b) Modelo estrutural
1 Elemento de topo
2 Elemento diagonal
Figura 55 Explicao dos smbolos para o clculo de bastidores de madeira [1]
69
Dimensionamento de Cimbres
Tipo de ligao
pin
CVD
N/mm
bar dowel
CVP
N/mm
25d2
34d2
11d2
15d2
3.8.2.4.3
cos
3.35
3.8.2.5
Foras e momentos
3.8.2.5.1
1
3.36
70
Dimensionamento de Cimbres
Onde:
Ncr a aco crtica e dada pela equao 3.37:
1
1
1
3.37
Onde:
NE a aco elstica de encurvadura do sistema estrutural;
Nd o valor de dimensionamento do somatrio das foras de compresso
Hd,i a soma das foras transversais de dimensionamento resultantes da aco externa
aplicada no topo da seco contraventada da estrutura;
Si a rigidez transversal (ver 3.8.2.4);
Onde:
Hd a fora transversal tendo em considerao a teoria de segunda ordem e dada pela
equao 3.36;
h a altura global;
M o momento flector tomando em considerao a teoria de segunda ordem.
3.8.2.5.2
Contraventamento de asnas
Este mtodo pode ser adoptado quando o somatrio da rigidez transversal de todos os
elementos de contraventamento transversal, T4, for superior a 40 % do somatrio das foras
verticais na viga. O contraventamento relevante apresentado na Figura 48. Poder ser expresso da
seguinte forma:
71
Dimensionamento de Cimbres
0,4
3.39
Onde:
Nd o somatrio de todas as aces verticais de dimensionamento do grupo de vigas;
Si a rigidez transversal do contraventamento horizontal entre as vigas.
A fora de dimensionamento terica, H, dever ser calculada utilizando a equao 3.40:
,
1
3.40
Onde:
l a distncia entre apoios;
e a imperfeio resultante de ns fixos de acordo com 3.7.4.1;
N o somatrio das foras de compresso mximas no topo dos banzos do grupo de asnas;
Ncr a carga crtica e dada pela equao 3.37.
O momento flector correspondente no plano horizontal a meio vo, M, dever ser
calculado usando a equao 3.41:
3.41
Dimensionamento de Cimbres
73
Dimensionamento de Cimbres
74
75
geometria, a frequncia correspondente ao 1 modo na medida em que este modo tem uma
influncia de 80 % na resposta total da estrutura a uma aco ssmica. Numa tentativa de avaliar a
geometria com melhor eficcia na estabilidade da estrutura registou-se tambm o produto entre o
deslocamento horizontal do topo da estrutura e a massa da estrutura. A massa da estrutura poder
ser traduzida pelo somatrio do produto entre o esforo axial de todos os elementos que constituem
a estrutura e o comprimento de cada elemento, equao 4.1:
, ,
, ,
, ,
4.1
Onde:
76
Modelao
M
coomputacionaal de cimbress ao solo
F
Figura
56 Geeometria de con
ntraventamentto A1
Figura
F
57 Geeometria de contraventamento A2
F
Figura
58 Geeometria de con
ntraventamentto A3
Figura
F
59 Geeometria de contraventamento A4
77
Figu
ura 60 Geomeetria de contraaventamento A5
A
Figu
ura 61 Geomeetria de contraaventamento A6
A
Figu
ura 62 Geomeetria de contraaventamento A7
A
Figu
ura 63 Geomeetria de contraaventamento A8
A
78
R
Regras
para o dimension
namento de cimbres em
m estruturas de beto armado
Modelao
M
coomputacionaal de cimbress ao solo
Figura 64 Geometria
G
de contraventame
c
ento A9
Figu
ura 65 Geom
metria de contraaventamento A10
A
Tabela 13 Resultados
R
da anlise
a
das geometrias de con
ntraventamentto: A
G. C.
Nbastidor
Ndiaagonal
Rapoio
horizonttal
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
56625,00
26625,01
28812,50
18875,00
734,96
26625,00
13311,87
746,05
750,00
750,00
4800,23
4800,24
2400,12
1600,08
2977,84
4033,89
2400,59
4288,69
4800,23
4800,23
6000,00
3000,01
3000,00
2000,00
966,004
3000,00
1500,16
990,331
1125,00
750,000
4,479
1,183
2,233
1,489
0,137
1,931
0,592
0,154
0,291
0,264
f1modo
[Hz]
2,65
5,06
3,43
3,89
12,68
3,86
6,54
11,61
9,72
10,89
horizontal x N x L
6565516,70
1022245,40
3242231,60
95917,98
76115,52
2799995,00
503220,00
84553,00
173229,05
15163,33
79
E ponderaao do facttor econmicco no deverr ser generaalizada uma vez que tod
Esta
dos os
alinhameentos verticcais de baastidores devero estaar contraveentados. Ass geometriaas de
contraveentamento A1,
A A2, A3, A4,
A A6 e A77 possuem alinhamentos
a
s no contravventados o que
q se
traduz em
m produtos entre
e
o deslocamento e a massa bastan
nte elevadoss.
P outro laddo, alterar a altura
Por
a
da estrrutura exige outra abordaagem de conntraventamen
nto, ou
seja, as geometrias de contraveentamento applicadas anteeriormente podero
p
no ser eficazess para
estruturaas com outraas alturas. Paara verificar este facto submetem-se cinco estrutturas (Figuraa 66
Figura 70)
7 s mesmaas condiess de carregam
mento. Na Tabela
T
14 estto apresentaados os resu
ultados
obtidos.
Figura
a 67 Geometrria de contraveentamento B2
Figura
a 69 Geometrria de contraveentamento B4
80
R
Regras
para o dimension
namento de cimbres em
m estruturas de beto armado
G. C. Nbastidor Ndiagonal
B1
B2
B3
B4
B5
140,26
207,09
162,18
170,16
200,00
129,48
224,82
207,70
277,71
312,70
Rapoio
horizontal
241,37
293,84
206,43
285,41
305,06
0,0077
0,0137
0,0123
0,0156
0,0195
f1modo
horizontal x N x L
[Hz]
61,14
77,14
114,47
65,08
111,50
68,38
154,74
62,33
172,28
58,45
81
ACO
DESIGNAO
QUANTIFICAO
Q1
1,0
Q2
Q3
1 % de Q1 + Q2
Q41
Q5x2
Laje: 6,5
Estrutura: 3,46
Q5y2
Laje: 6,5
Estrutura: 3,46
Q5z2
Laje: 6,5
Estrutura: 3,46
Q6x
0,20
Q6y
0,20
Q6z
0,20
Q7x2
14,85
Q7y3
14,85
Q7z3
4,95
Q8
Outras cargas:
temperatura,
assentamentos de apoio,
pr-esforo do beto
12,5 1,5
14,75
0,01
0,75
1,0
14,75
1,25
0,10 12,5
No considerada
82
Na aco Q1 considerou-se 1
, em que 0,5
4.3.2
83
DESIGNAO
Caso de carga 1
(Wmx,x)
1,35 1,0
1,35
1,5 0,7
1,05
Caso de carga 1
(Wmx,y)
1,35 1,0
1,35
1,5 0,7
1,05
Caso de carga 2
(Wtrab,x)
1,35 1,0
Caso de carga 2
(Wtrab,y)
1,35 1,0
Caso de carga 2
(Wtrab,z)
1,35 1,0
1,5 1,0
1,5
1,0
1,5
1,0
1,5
1,0
1,5
0,7
1,5 1,0
1,35
1,5
1,0
1,5
1,0
1,5
1,0
1,5
0,7
1,5 1,0
1,5
1,0
1,5
1,0
1,5
1,0
1,5
0,7
1,35
1,35
Caso de carga 3
(Wmx,x)
1,35 1,0
1,5 1,0
1,35
1,5
1,0
1,5
0,7
Caso de carga 3
(Wmx,y)
1,35 1,0
1,5 1,0
1,35
1,5
1,0
1,5
0,7
Caso de carga 3
(Wmx,z)
1,35 1,0
1,5 1,0
1,5
1,0
1,5
0,7
1,35
Caso de carga 4
(Ex)
1,0 1,0
1,0 0,7
0,7
0,7
0,7
Caso de carga 4
(Ey)
1,0 1,0
1,0 0,7
0,7
0,7
0,7
84
DESIGNAO
Caso de carga 1
(Wmx,x)
1,0 1,0
1,0 0,7
0,7
Caso de carga 1
(Wmx,y)
1,0 1,0
1,0 0,7
0,7
Caso de carga 2
(Wtrab,x)
1,0 1,0
1,0 1,0
1,0
1,0
1,0
0,7
Caso de carga 2
(Wtrab,y)
1,0 1,0
1,0 1,0
1,0
1,0
1,0
0,7
Caso de carga 2
(Wtrab,z)
1,0 1,0
1,0 1,0
1,0
1,0
1,0
0,7
Caso de carga 3
(Wmx,x)
1,0 1,0
1,0 1,0
1,0
0,7
Caso de carga 3
(Wmx,y)
1,0 1,0
1,0 1,0
1,0
0,7
Caso de carga 3
(Wmx,y)
1,0 1,0
1,0 1,0
1,0
0,7
Caso de carga 4
(Ex)
1,0 1,0
1,0 0,7
0,7
0,7
Caso de carga 4
(Ey)
1,0 1,0
1,0 0,7
0,7
0,7
0,7
No foi considerado vento nem efeitos ssmicos na direco z no caso de carga 1 (varivel
de base: peso prprio) e no caso de carga 4 (varivel de base: aco ssmica) porque so favorveis.
4.3.3
85
A
Atravs
do estudo realiizado no suubcaptulo 4.2 utiliza-see para o moodelo numrrico a
geometriia de contravventamento A10.
A
Para alm da verificcao da geoometria maiss eficaz num plano
de bastiddores imperativo analiisar quantos so os plan
nos que neceessitam de sser contraven
ntados
(Figura 72 Figura 75) tendo esspecial ateno para dois aspectos: a estabilidadde da estrutura e o
factor ecconmico.
P
Para
tal, faz--se uma anllise comparaativa entre o peso
p
do sisteema de contrraventamento
o com
o deslocamento globbal da estrutuura para se pooder analisarr a variao dos deslocam
mentos. O peeso do
o nmero dee barras que o sistema possui.
p
sistema de contravenntamento poode ser quanntificado pelo
T
18 e Figura
F
76, pode-se
p
conccluir acerca de
d quantos sso os plano
os que
Com estta anlise, Tabela
necessitaam de ser conntraventadoss no modelo numrico.
86
R
Regras
para o dimension
namento de cimbres em
m estruturas de beto armado
LEGENDA:
--- no contraventado
___
contraventado
N de planos
contraventados
2
0,0720
0,0410
4*
0,0413
0,0313
87
* esta anlise varia da anterior apenas na localizao relativa dos planos interiores contraventados
que se encontram mais afastados do centro.
0.0800
0.0700
0.0600
0.0500
0.0400
0.0300
0.0200
0.0100
0.0000
0
n de planos contraventados
Figura 76 Evoluo do deslocamento global da estrutura com o n de planos contraventados
Como se pode verificar atravs da anlise da Tabela 18 e da Figura 76, utilizando quatro
planos de contraventamento em vez de dois existe um decrscimo do deslocamento em 43,70 %.
Esta evoluo refere-se ao caso em que os planos interiores se localizam no centro da estrutura. Por
outro lado, a reduo do deslocamento da estrutura com quatro planos de contraventamento para
seis de 23,78 %. A reduo do deslocamento global da estrutura com o aumento dos planos de
contraventamento no linear uma vez que os planos no contraventados tambm vo contribuir
para o travamento da estrutura. Este facto comprova-se pelas reaces verticais existentes nos
apoios destes planos. Logo, tendo em considerao o factor econmico, utilizam-se quatro planos
de contraventamento (Figura 77 e Figura 71).
88
Modelao
M
coomputacionaal de cimbress ao solo
Figura 77 Planos
P
de conttraventamento
o nas duas direces horizonttais
Depois dee modelada a estrutura e introduzidass as aces e combinaees necessriaas obtmse oss esforos axxiais mxim
mos dos elem
mentos que constituem a estrutura. Retira-se taambm o
desloocamento gloobal mximoo da estruturra. A Tabela 19 resume esta anlise para os trss tipos de
elemeentos.
T
Tabela
19 Esfforo axial mxximo, Nmax, dos elementos e deslocamento
d
g
global
mximoo, max, da estrrutura
51,75
verrtical
Nmax
Elemento
horiizontal 166,89
[kN]
277,41
dia
agonal
max
0,00001
Estrutura
[m]
4.3.3..1
Verificaao de segu
urana
Depois de
d registados os valores de esforo axial
a
e desloocamento mximos, veriifica-se a
segurrana em E.L
L.U. (esforoo axial e enccurvadura), Tabela
T
20 e Tabela 21 reespectivamen
nte, e em
E.L.S
S. (deformao), Tabela 22. Nesta annlise suficciente efectuaar verificaes para os elementos
e
sujeittos ao esforo axial maiis elevado (elementos verticais)
v
na medida em que sero utilizados
u
elemeentos com a mesma seco transversaal em toda a estrutura.
89
0,00046 m2
fyd
275 MPa
Nc,Rd
127,65 kN
NEd
51,75 kN
Verificao
O.K!
210 GPa
5,63 m4
lencurvadura
2,5 m
Ncr
186,72 MPa
0,00046 m2
fy
275 MPa
0,83
0,21
0,91
0,95
Nb,Rd
121,83 kN
NEd
51,75 kN
Verificao
O.K!
90
[m] Verificao
L [m]
max [m]
2,5
0,0001
0,005
5,0
0,000013
0,01
7,5
0,0001
0,015
10,0
0,0005
0,02
12,5
0,0003
0,025
15,0
0,0001
0,03
17,5
0,0001
0,035
20,0
0,0001
0,04
O.K!
91
92
Segurana
5 Segurana
5.1 Generalidades
Depois de concluda a fase de projecto onde realizado o dimensionamento do sistema de
cimbres com as consideraes descritas anteriormente vem a fase de execuo, a montagem dos
cimbres. Nesta fase existem cuidados e preocupaes a ter em considerao. So tomadas medidas
de segurana impostas por uma entidade reguladora.
Um exemplo de situao de risco a remoo arbitrria de prumos que impedem os
trabalhos em curso, ignorando a sua funo. Os prumos nunca devero ser removidos sem
autorizao prvia do projectista, uma vez que estes s podero ser removidos quando oi beto
adquirir a resistncia necessria para se auto suportar, para alm de que parte dos prumos iro
desempenhar a funo de ps-escoramento.
Em Portugal no existe nenhum organismo que preconize medidas de segurana. No
entanto, noutros pases como os E.U.A., esto definidas regras para a montagem, utilizao e
desmontagem dos cimbres.
Afixar regras de segurana num local visvel e ter a certeza que todas as pessoas que
montam, desmontam e manuseiam cimbres tm conhecimento delas;
Inspeccionar o local de trabalho. Deve ser feita uma inspeco por uma pessoa qualificada
do local de trabalho para detectar perigos, tais como buracos, valas, detritos, cabos de alta
tenso, buracos sem proteco e outras situaes perigosas;
93
Segurana
Inspeccionar todo o equipamento antes do seu uso. Nunca, em qualquer caso, usar
equipamento estruturalmente danificado. Marc-lo como danificado e remov-lo, de
seguida, do local de trabalho;
Deve ser preparado um plano de escoramento por uma pessoa qualificada para analisar a
carga a que o escoramento vai estar sujeito e estar coerente com as cargas que permitem
estar em segurana fornecidas pelo fabricante, em todas as obras;
Montar, desmontar ou alterar qualquer sistema de escoramento deve ser supervisionado por
uma pessoa qualificada;
94
Concluses
6 Concluses
No suporte de construo em beto armado de vrios pisos necessrio efectuar
escoramento, pr-escoramento e ps-escoramento. Na Europa este suporte, com prumos
extensveis, ou o suporte de viadutos, pontes ou passagens superiores e inferiores, com sistemas de
cimbres ao solo, so realizados em ao galvanizado ou em alumnio. No entanto, com a pesquisa
efectuada, conclui-se que os perfis pultrudidos em fibra renem as caractersticas necessrias para
desempenhar a funo de suporte destas estruturas temporrias. Uma vez que as estruturas possuem
exigncias construtivas prprias existem diferentes tipos de sistemas de cimbres: prumos
extensveis, sistemas de cimbres ao solo em torre ou modulares.
As aces a considerar para o dimensionamento estrutural de estruturas temporrias de
suporte dividem-se em dois grupos: aces directas e aces indirectas. As aces directas
englobam aces permanentes (peso prprio da estrutura, da cofragem e dos lastros); aces
variveis impostas (peso prprio do beto armado); aces variveis impostas de curta durao
(sobrecarga de betonagem); aco do vento e efeitos ssmicos. As aces indirectas so
deslocamentos impostos estrutura de cimbres que resultam da variao da temperatura, de
assentamentos de apoio diferenciais ou do pr-esforo do beto armado.
Os problemas de instabilidade ao nvel esttico que se podem encontrar neste tipo de
estruturas e que devero ser considerados na sua anlise de dimensionamento so o deslizamento
global da estrutura, o deslizamento local nos elementos individuais, o derrubamento e a suco. As
excentricidades das aces e das ligaes devem ser tidos em conta assim como a encurvadura dos
elementos. A anlise do sistema de contraventamento imperativa para uma optimizao da
estabilidade estrutural uma vez que estas estruturas so articuladas, ou seja, possuem grande
liberdade de translao e de rotao.
Pela anlise do sistema de contraventamento conclui-se que o nmero de elementos que
constituem o sistema de contraventamento no directamente proporcional sua eficcia e que a
sua geometria vai variar com a altura da estrutura a contraventar. Conclui-se tambm que quanto
maior for o nmero de alinhamentos verticais de bastidores contraventados maior ser a eficcia do
sistema de contraventamento. Numa torre de cimbres ao solo o aumento de planos de
contraventamento faz diminuir o deslocamento global da estrutura mas no de uma forma linear,
logo conclui-se que tendo em conta a eficcia e o factor econmico no necessrio que todos os
planos de uma estrutura de cimbres se encontrem contraventados.
Apesar de no existir nenhuma entidade em Portugal que defina regras de segurana nas
fases de montagem, manuseamento e desmontagem das estruturas de cimbres, outros pases como
por exemplo os E.U.A. possuem legislao neste campo. Estas medidas servem no s para
Regras para o dimensionamento de cimbres em estruturas de beto armado
95
Concluses
proteger os trabalhadores mas tambm para que a estrutura no perca a funo para a qual foi
projectada. Ser um passo a dar por Portugal.
96
Referncias Bibliogrficas
7 Referncias Bibliogrficas
[1] CEN European Committee for Standardization; EN 12812: Falsework Performance
requirements and general design; Brussels; June 2004.
[2] DIN - Deutsches Institut fr Normung; DIN 4421: Falsework Calculation, design and
construction; Berlin, August 1982
[3] http://www.wemotechnik.com/ (3 de Junho de 2008)
[4] http://www.peri.pt/ (3 de Junho de 2008)
[5] The difference between shoring and scaffolding; SSFI Technical Bulletin. Scaffolding; Shoring
and Forming Institute, Inc. Shoring Section; Maio 2003.
[6] http://www.antonioejoao.pt/ (3 de Junho 2008)
[7] http://www.dustrimetal.pt/ (3 de Junho de 2008)
[8] http://cenasdacidade.files.wordpress.com (3 de Junho de 2008)
[9] Doka international; Beto vista com cofragens Doka; Setembro 2006
[10] http://www.symons.com/ (4 de Junho de 2008)
[11] Shoring, reshoring, preshoring (backshoring); SSFI Technical Bulletin. Scaffolding, Shoring
and Forming Institute, Inc.; Shoring Section; Novembro 2003.
[12] http://www.peri.pt/ (4 de Junho de 2008)
[13] http://www.strombergarchitectural.com/ (4 de Junho de 2008)
[14] Sutcliffe, Michael; Design practicalities I: Design methodology, laminate selection and joints;
Module B2 Designing with composites; Engineering Science Part IIB, EIST Part II.
[15] Peri; Handbook 2008; Formwork Scaffolding Engineering.
[16] Ulma construccin; brochura: cimbre.
[17] ACI 347-01; Guide to Formwork for Concrete.
[18] http://www.peri.pt/ (4 de Junho de 2008)
[19] Peng, J.L.; Pan, A.D.E.; Chan, S.L.; Simplified models for analysis and design of modular
falsework; Elsevier; Journal of Construction Steel Research 48 pginas 189 209; 1998.
[20] Wind loads and shoring; SSFI Technical Bulletin; Scaffolding, Shoring and Forming Institute,
Inc.; Shoring Section; Dezembro 2003.
Regras para o dimensionamento de cimbres em estruturas de beto armado
97
Referncias Bibliogrficas
98
Apndice
Apndice
A.1. Quantificao do vento mximo
A quantificao do vento mximo, [22] e [27], uma quantificao representativa uma vez
que os parmetros e coeficientes adoptados para a anlise em 4.3 so os mais desfavorveis.
Rugosidade do solo:
II
Zona:
B
Altura da torre de cimbres ao solo:
Factor de rugosidade:
com
com
,
,
,
Factor do solo:
,
Intensidade de turbulncia:
Regras para o dimensionamento de cimbres em estruturas de beto armado
99
Apndice
com
com
,
,
Coeficiente de presso de superfcies em grelha:
Tabela 23 Coeficientes de presso recomendados,
Obstruo
Zona
Sem esquina
,0
2,3
1,4
1,2
1,2
2,9
1,8
1,4
1,2
10
3,4
2,1
1,7
1,2
2,1
1,8
1,4
1,2
1,2
,
,
,
,
100
,
,
,
Apndice
1,85
,
Figura 78 Coeficiente de fora Cf,0 para estruturas com elementos individuais de seco circular [27]
,
Para
Para
,
,
101
Apndice
0,98
0,88
0,83
0,74
0,62
1,26
Figura 80 Valores para funo do grau de solidez e da esbelteza [27]
102
Apndice
Zona:
A
Tipo de terreno:
III
Frequncia de resposta no 1 modo de vibrao:
,
Coeficiente de amortecimento:
%
Acelerao:
220
210
1,72
Figura 81 - Determinao da acelerao atravs da frequncia [23]
Verifica-se que para a aco ssmica tipo 2 obtm-se uma valor para a acelerao mais elevado.
Regras para o dimensionamento de cimbres em estruturas de beto armado
103
Apndice
Logo considera-se
Peso da cofragem:
Peso do beto armado:
,
,
,
104