Escolar Documentos
Profissional Documentos
Cultura Documentos
FORMULÁRIO
RESULTADO DO TESTE
Examination Results
SUPERFÍCIE
SOLDADORES
EXAMINADA
Welders
Exam. Surface
CORDÃO OU ÁREA IEIS / PLANO
TIPO RESULTADO OBSERVAÇÃO
EXAMINADA Nº DE SOLDA
Type Result Remarks
Weld or Examination Area INTERNA EXTERNA RAIZ ACAB Welding Plan
Inside Out Side Root Cap
- - X 1 F - X A CORTE A-A
-
- X 2 F - X A CORTE A-A
-
- X 3 F - X A CORTE A-A
-
- X 4 F - X A CORTE A-A
-
- X 5 F - X A CORTE A-A
-
- X 6 F - X A CORTE A-A
-
- X 7 F - X A CORTE A-A
-
- X 8 F - X A CORTE A-A
-
- X 9 F - X A CORTE A-A
-
- X 10 F - X A CORTE A-A
-
- X 11 F - X A CORTE A-A
-
- X 12 F - X A CORTE A-A
-
- X 13 F - X A CORTE A-A
-
- X 14 F - X A CORTE A-A
-
- X 15 F - X A CORTE A-A
-
- X 16 F - X A CORTE A-A
LEGENDA:
A = APROVADO R = REPROVADO REC = RECOMENDAÇÃO DE EXAME COMPLEMENTAR
Approved Rejected Recommendation of Complementary Examination
BRASA INSPETOR / BRASA Inspector BRASA COORDENADOR DE CQ / BRASA CLIENTE / Client CLASSIFICADORA / Surveyor
QC Coordinator