COD. REVENDEDOR: N° O.S. (Service Order) CLIENTE (Customer) EMBARCAÇÃO OU EQUIPAMENTO (Vessel or equipament)
SINTOMAS APRESENTADOS
(Failure showed) VAZAMENTO DE AGUA PELO RESFRIADOR DE PLACAS
COMENTÁRIOS
N° DA PEÇA CAUSADORA DA FALHA NOME DA PEÇA DESC. N° DO GRUPO NOME DO GRUPO FORA DE OPERAÇÃO?
C QTD ADICIONAIS
(failure responsable part number) (Part name) PROB. (Group number) (Group name) (Downtime)
A (comments)
R SIM (Yes)
T NÃO (no)
à SIM (Yes)
O NÃO (no)
DESCRIÇÃO POSIÇÃO DO MOTOR SÉRIE ARRANJO INDIQUE SE COM O PROBLEMA OCORRIDO, A MÁQUINA FICOU SEM CONDIÇÕES DE
S (Description) (Engine position) (Serial Number) (Arrange) OPERAÇÃO. (you should informer if the engine was in downtime)
I GRUPO GERADOR CÓDIGO DE DESCRIÇÃO DO PROBLEMA (TROUBLE DESCRIPTION CODE)
(Generator group) A- ESTRUTURAL (STRUCTURAL) F- EMBARQUE DE FÁBRICA (SHIPING)
M
B- SUPERFICIE (SURFACE) G- REVISÃO (REVISION)
S MOTOR (engine) FIRE PUMP (FWD) 33166788 C- VAZAMENTO (LEAKAGE) H- AJUSTAGEM (ADJUSTMENT)
D- MONTAGEM OU PROC.FABRIC. (ASSEMBLY) K- DIFICULDADE DE MANUTENÇÃO
GERADOR E- FALHA DO SISTEMA (SYSTEM FAILURE) (MAINTENANCE DIFFICULTIES)
(Generator) N- ACIDENTE OU ABUSO (ACCIDENT)
PLACA:
Veículo Utilizado (Used Vehicle): KM Total (Total kilometer):
(License Plate):
BACIA DE SANTOS
CRISTIANO COSTA DATA (Date)
SERVIÇOS REALIZADOS
AO CHEGAR A BORDO, FUI DIRECIONADO AO SUPERVISOR DE MANUTENÇÃO , O MESMO ME INFORMOU
QUE O PESSOAL DE BORDO( SBM) JÁ HAVIAM SOLUCIONADO O VAZAMENTO , OS MESMOS DESMONTARAM
O RESFRIADOR, LIMPARAM AS PLACAS E MONTARAM NOVAMENTE. FOI REALIZADO O FUNCIONAMENTO
DO MOTOR E REALIZADO O TESTE DE PERFORMACE COM 99% DE CARGA, E O MESMO NÃO APRESENTOU
NENHUM VAZAMENTO PELO RESFRIADO DE PACAS. TODAS AS INFORMAÇÕES PASSADAS ACIMA FORAM
INFORMADAS PELO SUPERVISOR DE MANUTENÇÃO DE BORDO .
OBSERVAÇÕES
O6/10/21- SAIDA DO HOTEL 04:30 CHEGADA NO AEROPORTO AS 05:10. APÓS O BRIFING SAIDA DA AERONAVE AS 06:30
CHEGNADO A BORDO AS 07:30