Você está na página 1de 28

Espessura fator

5.08 1.47
5.10 1.45
5.12 1.44
5.16 1.43
5.18 1.42
5.20 1.41
5.22 1.40
5.24 1.39
5.28 1.38
5.29 1.37
5.31 1.36
5.33 1.35
5.35 1.34
5.38 1.33
5.40 1.32
5.42 1.31
5.45 1.30
5.47 1.29
5.49 1.28
5.51 1.27
5.54 1.26
5.56 1.25
5.58 1.24
5.61 1.23
5.63 1.22
5.66 1.21
5.68 1.20
5.71 1.19
5.74 1.18
5.77 1.17
5.81 1.16
5.84 1.15
5.87 1.14
5.90 1.13
5.93 1.12
5.97 1.11
6.00 1.10
6.03 1.09
6.06 1.08
6.09 1.07
6.11 1.06
6.14 1.05
6.19 1.04
6.23 1.03
6.27 1.02
6.31 1.01
6.35 1.00
6.39 0.99
6.43 0.98
6.47 0.97
6.51 0.96
6.56 0.95
6.61 0.94
6.67 0.93
6.71 0.92
6.75 0.91
6.79 0.90
6.83 0.89
6.88 0.88
6.93 0.87
6.99 0.86
7.03 0.85
7.08 0.84
7.14 0.83
7.22 0.82
7.30 0.81
7.35 0.80
7.40 0.79
7.46 0.78
7.54 0.77
7.62 0.76
Cliente: VIA PAULISTA

ESTATISTICO

Dens. Ap. (Gmb)

Temperatura

Temperatura
DMT (Gmm)
Estabilidade
Teor (Pb)

do CAUQ
Fluência

do CAP
Composição Granulometrica da Mistura Asfáltica

RTCD
Período

Vam

Rbv
Vv
Data

( em percentual passante)

(%) (MPa) (kN) (mm) (adm) (adm) (%) (%) (%) 19 16 12.5 9.52 4.75 2 0.425 0.18 0.075 °C °C
11/04/23 MANHÃ 5.25% 2.36 1537.9 10.04 2.641 2.542 3.72% 17.12% 78.26% 100% 95% 86% 74% 49% 28% 13% 10% 8% 150 160

N 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

K1 #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A

MÉDIA 5.25% 2.36 1537.9 10.0 2.641 2.542 3.7% 17.1% 78.3% 100% 95% 86% 74% 49% 28% 13.0% 10.0% 7.9% 150 160

D. PADRÃO #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

LIMITE MÍNIMO #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

LIMITE MÁXIMO #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

DADOS DO PROJETO

FAIXA DE TRABALHO

MÍNIMO 93% 89% 75% 61% 41% 24% 7% 6.1% 4.5%

MÁXIMO 100% 100% 89% 75% 51% 34% 17% 12.1% 8.5%
ENSAIO EXTRAÇÃO, GRANULOMETRIA E MARSHALL

Rodovia: SP- 328 Coleta: USINA 02 Trecho: Concessionária Via Paulista S/A Nº: MANHÃ
Km Inicial: Km 298+560 contratada: Val Rocha Eng Projeto Mistura: Asfática a Quente ( MAQ ) Data Coleta: 11/04/23
Km Final: Km 298+750 Amostra: Pedreira Jardinopólis Laboratorista: EQUIPE Data Ensaio: 11/04/23
Pista: NORTE FAIXA: 9 -SPV 16,0 Capa Rolamento Resp.pela Coleta: WELINGTON SOUZA Eng.Resp.: LEONARDO BERTELLI
CONTRATO: TIPO DE SERVIÇO: COLETA : 5ª CAMINHÃO

PESO DA EXTRAÇÃO DE BETUME DA AMOSTRA


PENEIRA 1,127.90 g FAIXA DE TRABALHO
AMOSTRA DESCRIÇĀO SOXLET MUFA

ETO
Peso com Betume 1,206.90

OJ
PR
ASTM mm Peso acum. % retida % Passan. Min Max
Peso sem Betume 1,127.90
3/4" 19 0.00 0.0% 100% 100% 93% 100% Peso Betume 79.00
5/8" 16 50.80 4.5% 95.5% 96% 89% 100% % de Betume 6.55%
1/2" 12.7 156.2 13.8% 86.2% 82% 75% 89% Fator Correção Queima Mufa 1.30%
3/8" 9.5 298.5 26.5% 73.5% 68% 61% 75% Teor de betume adotado 5.25%
Nº 4 4.8 571.5 50.7% 49.3% 46% 41% 51%
Nº 10 2 813.9 72.2% 27.8% 29% 24% 34% ENSAIO DE MASSA ESPECIFICA MÁXIMA RICE)
Nº 40 0.59 981.8 87.0% 13.0% 12% 7% 17% Peso da amostra 1,540.1
Nº 80 0.18 1,015.0 90.0% 10.0% 9.1% 6.1% 12.1% Peso do frasco+agua 25oC 7,066.8
Nº 200 0.075 1,038.4 92.1% 7.9% 6.5% 4.5% 8.5% Peso frasco+agua+amostra 25oC 8,606.9
Frasco+agua+amostra vácuo 25oC 8,023.7
Volume (cm3) 583.2
M.E. Teor. (Rice) 2.641
9

2
1
100%
M.E.Ef. Mistura seca 2.890

80%

DADOS DO PROJETO
Teor de projeto 5.0%
60%
Dens. Real do CAP 1.033
M.E.SOLTA (RICE) 2.632
40% M.E.Ef. Mistura seca 2.867

20%

0%
0.07 0.7 7

MIX PROJETO FAIXA DE TRABALHO

Constante do anel 2.060 ESTABILIDADE MARSHALL RESISTENCIA À TRAÇÃO


K fluencia 0.254 CP 1 2 3 4 5 6 7
Altura 5.10 5.93 5.98
Diametro 9.90 10.15 10.12
Peso ao Ar (g) 1,186.40 1,182.18 1,181.30 Fator 1.45 1.12 1.11
Peso ao Ar (Saturado, Sup. Seca)(g) 1,188.53 1,184.28 1,183.44 Leitura 625 632 638
Peso na Água (4 minutos imerso) (g) 721.77 719.66 718.59 R. T. 2.36 1.54 1.54
Vol. Do Corpo de Prova 466.76 464.62 464.85 0.00 LIMITES
Média PROJETO
Fator de correção 1.18 1.19 1.19 0.00 MÍNIMO MÁXIMO
Densidade Aparente 2.542 2.544 2.541 2.542 2.500
Densidade Teórica 2.641 2.641 2.641 0.000 2.641 2.632
% VAZIOS (MÉTODO SUPERPAVE) 3.75% 3.65% 3.77% 3.7% 5.0% 3.0% 5.0%
% V. C. B. (MÉTODO SUPERPAVE) 16.1% 16.1% 16.1% 16.1% 11.5%
% V. A M. (MÉTODO SUPERPAVE) 17.1% 17.1% 17.2% 17.1% 16.3% > 13,0% 15.0%
% R. B. V. 78.1% 78.6% 78.0% 78.3% 69.3% 65.0% 75.0%
Leitura do Deflectômetro 625 632 638 632
Estabilidade Encontrada (kg) 1,288 1,302 1,314 1,301
Resistência a Tração Indireta a 25°C (Mpa) 1,522 1,539 1,553 1,538 1.1
Deformação do cp MAQ a25°C ( m.m) 9.93 10.06 10.12 10.04 5.6
OBSERVAÇÕES:

CONCLUSÃO DO ENSAIO:
ENSAIO EXTRAÇÃO, GRANULOMETRIA E MARSHALL

Rodovia: SP- 328 Coleta: USINA 02 Trecho: Concessionária Via Paulista S/A Nº: MANHÃ
Km Inicial: USINA: Val Rocha Eng Projeto Mistura: Asfática a Quente ( MAQ ) Data Coleta: 02/05/23
Km Final: Amostra: Pedreira Jardinopólis Laboratorista: EQUIPE Data Ensaio: 02/05/23
Pista: NORTE FAIXA: 9 -SPV 16,0 Capa Rolamento Resp.pela Coleta: WELINGTON SOUZA Eng.Resp.: LEONARDO BERTELLI
CONTRATO: TIPO DE SERVIÇO: COLETA : 2ª CAMINHÃO

PESO DA EXTRAÇÃO DE BETUME DA AMOSTRA


PENEIRA 1,707.10 g FAIXA DE TRABALHO
AMOSTRA DESCRIÇĀO MUFA

E TO
Peso com Betume 1,823.90

OJ
PR
ASTM mm Peso acum. % retida % Passan. Min Max
Peso sem Betume 1,707.10
3/4" 19 0.00 0.0% 100% 99.8% 93% 100% Peso Betume 116.80
5/8" 16 111.70 6.5% 93.5% 95.5% 89% 100% % de Betume 6.40%
1/2" 12.7 314.3 18.4% 81.6% 81.7% 75% 89% Fator Correção Queima Mufa 1.30%
3/8" 9.5 475.1 27.8% 72.2% 68.4% 61% 75% Teor de betume adotado 5.10%
Nº 4 4.8 898.6 52.6% 47.4% 45.9% 41% 51%
Nº 10 2 1,283.3 75.2% 24.8% 28.6% 24% 34% ENSAIO DE MASSA ESPECIFICA MÁXIMA RICE)
Nº 40 0.59 1,530.6 89.7% 10.3% 12.1% 7% 17% Peso da amostra 2,740.6
Nº 80 0.18 1,575.0 92.3% 7.7% 9.1% 6.1% 12.1% Peso do frasco+agua 25oC 7,070.5
Nº 200 0.075 1,601.7 93.8% 6.2% 6.5% 4.5% 8.5% Peso frasco+agua+amostra 25oC 9,811.1
Frasco+agua+amostra vácuo 25oC 8,768.1
Volume (cm3) 1,043.0
M.E. Teor. (Rice) 2.628
9

2
1
100%
M.E.Ef. Mistura seca 2.866

EXTRAÇÃO NÃO CONFORME


80%

DADOS DO PROJETO
Teor de projeto 5.0%
60%
Dens. Real do CAP 1.033
M.E.SOLTA (RICE) 2.632
40% M.E.Ef. Mistura seca 2.867

20%

0%
0.07 0.7 7

MIX PROJETO FAIXA DE TRABALHO


FAIXA DE TRABALHO

Constante do anel 2.060 ESTABILIDADE MARSHALL RESISTENCIA À TRAÇÃO


K fluencia 0.254 CP 1 2 3 4 5 6 7
Altura
Diametro
Peso ao Ar (g) Fator
Peso ao Ar (Saturado, Sup. Seca)(g) Leitura
Peso na Água (4 minutos imerso) (g) R. T.
Vol. Do Corpo de Prova 0.00 LIMITES
Média PROJETO
Fator de correção 0.00 MÍNIMO MÁXIMO
Densidade Aparente 2.500
Densidade Teórica 0.000 2.632
% VAZIOS (MÉTODO DNER) 5.0% 3.0% 5.0%
% V. C. B. (MÉTODO SUPERPAVE) 11.5%
% V. A M. (MÉTODO SUPERPAVE) 16.3% > 13,0% 15.0%
% R. B. V. 69.3% 65.0% 75.0%
Leitura do Deflectômetro
Estabilidade Encontrada (kg)
Estabilidade Corrigida (kg) 1,052 > 700
Fluência, Leitura (mm) 11.0 8 16
OBSERVAÇÕES:

CONCLUSÃO DO ENSAIO:
PROBLEMAS NA M.E./ENSAIO RICE- REFAZER ENSAIO COM MESMA AMOSTRA.
#VALUE!
ENSAIO EXTRAÇÃO, GRANULOMETRIA E MARSHALL

Rodovia: SP- 328 Coleta: USINA 02 Trecho: Concessionária Via Paulista S/A Nº: MANHÃ
Km Inicial: USINA: Val Rocha Eng Projeto Mistura: Asfática a Quente ( MAQ ) Data Coleta: 03/05/23
Km Final: Amostra: Pedreira Jardinopólis Laboratorista: EQUIPE Data Ensaio: 03/05/23
Pista: NORTE FAIXA: 9 -SPV 16,0 Capa Rolamento Resp.pela Coleta: WELINGTON SOUZA Eng.Resp.: LEONARDO BERTELLI
CONTRATO: TIPO DE SERVIÇO: COLETA : 2ª CAMINHÃO

PESO DA EXTRAÇÃO DE BETUME DA AMOSTRA


PENEIRA 1,749.50 g FAIXA DE TRABALHO
AMOSTRA DESCRIÇĀO MUFA

E TO
Peso com Betume 1,869.70

OJ
PR
ASTM mm Peso acum. % retida % Passan. Min Max
Peso sem Betume 1,749.50
3/4" 19 0.00 0.0% 100% 99.8% 93% 100% Peso Betume 120.20
5/8" 16 100.80 5.8% 94.2% 95.5% 89% 100% % de Betume 6.43%
1/2" 12.7 332.0 19.0% 81.0% 81.7% 75% 89% Fator Correção Queima Mufa 1.30%
3/8" 9.5 488.7 27.9% 72.1% 68.4% 61% 75% Teor de betume adotado 5.13%
Nº 4 4.8 929.6 53.1% 46.9% 45.9% 41% 51%
Nº 10 2 1,285.1 73.5% 26.5% 28.6% 24% 34% ENSAIO DE MASSA ESPECIFICA MÁXIMA RICE)
Nº 40 0.59 1,547.3 88.4% 11.6% 12.1% 7% 17% Peso da amostra 2,528.5
Nº 80 0.18 1,597.4 91.3% 8.7% 9.1% 6.1% 12.1% Peso do frasco+agua 25oC 7,070.5
Nº 200 0.075 1,626.8 93.0% 7.0% 6.5% 4.5% 8.5% Peso frasco+agua+amostra 25oC 9,599.0
Frasco+agua+amostra vácuo 25oC 8,636.0
Volume (cm3) 963.0
M.E. Teor. (Rice) 2.626
9

2
1
100%
M.E.Ef. Mistura seca 2.864

EXTRAÇÃO NÃO CONFORME


80%

DADOS DO PROJETO
Teor de projeto 5.0%
60%
Dens. Real do CAP 1.033
M.E.SOLTA (RICE) 2.632
40% M.E.Ef. Mistura seca 2.867

20%

0%
0.07 0.7 7

MIX PROJETO FAIXA DE TRABALHO


FAIXA DE TRABALHO

Constante do anel 2.060 ESTABILIDADE MARSHALL RESISTENCIA À TRAÇÃO


K fluencia 0.254 CP 1 2 3 4 5 6 7
Altura
Diametro
Peso ao Ar (g) Fator
Peso ao Ar (Saturado, Sup. Seca)(g) Leitura
Peso na Água (4 minutos imerso) (g) R. T.
Vol. Do Corpo de Prova 0.00 LIMITES
Média PROJETO
Fator de correção 0.00 MÍNIMO MÁXIMO
Densidade Aparente 2.500
Densidade Teórica 0.000 2.632
% VAZIOS (MÉTODO DNER) 5.0% 3.0% 5.0%
% V. C. B. (MÉTODO SUPERPAVE) 11.5%
% V. A M. (MÉTODO SUPERPAVE) 16.3% > 13,0% 15.0%
% R. B. V. 69.3% 65.0% 75.0%
Leitura do Deflectômetro
Estabilidade Encontrada (kg)
Estabilidade Corrigida (kg) 1,052 > 700
Fluência, Leitura (mm) 11.0 8 16
OBSERVAÇÕES:

CONCLUSÃO DO ENSAIO:
PROBLEMAS NA M.E./ENSAIO RICE- REFAZER ENSAIO COM MESMA AMOSTRA.
#VALUE!
ENSAIO EXTRAÇÃO, GRANULOMETRIA E MARSHALL

Rodovia: SP- 328 Coleta: USINA 02 Trecho: Concessionária Via Paulista S/A Nº: MANHÃ
Km Inicial: USINA: Val Rocha Eng Projeto Mistura: Asfática a Quente ( MAQ ) Data Coleta: 04/05/23
Km Final: Amostra: Pedreira Jardinopólis Laboratorista: EQUIPE Data Ensaio: 04/05/23
Pista: NORTE FAIXA: 9 -SPV 16,0 Capa Rolamento Resp.pela Coleta: WELINGTON SOUZA Eng.Resp.: LEONARDO BERTELLI
CONTRATO: TIPO DE SERVIÇO: COLETA : 2ª CAMINHÃO

PESO DA EXTRAÇÃO DE BETUME DA AMOSTRA


PENEIRA 1,755.90 g FAIXA DE TRABALHO
AMOSTRA DESCRIÇĀO MUFA

E TO
Peso com Betume 1,870.40

OJ
PR
ASTM mm Peso acum. % retida % Passan. Min Max
Peso sem Betume 1,755.90
3/4" 19 0.00 0.0% 100% 99.8% 93% 100% Peso Betume 114.50
5/8" 16 83.60 4.8% 95.2% 95.5% 89% 100% % de Betume 6.12%
1/2" 12.7 339.6 19.3% 80.7% 81.7% 75% 89% Fator Correção Queima Mufa 1.30%
3/8" 9.5 560.3 31.9% 68.1% 68.4% 61% 75% Teor de betume adotado 4.82%
Nº 4 4.8 994.0 56.6% 43.4% 45.9% 41% 51%
Nº 10 2 1,318.4 75.1% 24.9% 28.6% 24% 34% ENSAIO DE MASSA ESPECIFICA MÁXIMA RICE)
Nº 40 0.59 1,592.9 90.7% 9.3% 12.1% 7% 17% Peso da amostra 2,572.5
Nº 80 0.18 1,635.9 93.2% 6.8% 9.1% 6.1% 12.1% Peso do frasco+agua 25oC 7,069.6
Nº 200 0.075 1,661.5 94.6% 5.4% 6.5% 4.5% 8.5% Peso frasco+agua+amostra 25oC 9,642.1
Frasco+agua+amostra vácuo 25oC 8,666.1
Volume (cm3) 976.0
M.E. Teor. (Rice) 2.636
9

2
1
100%
M.E.Ef. Mistura seca 2.861

EXTRAÇÃO NÃO CONFORME


80%

DADOS DO PROJETO
Teor de projeto 5.0%
60%
Dens. Real do CAP 1.033
M.E.SOLTA (RICE) 2.632
40% M.E.Ef. Mistura seca 2.867

20%

0%
0.07 0.7 7

MIX PROJETO FAIXA DE TRABALHO


FAIXA DE TRABALHO

Constante do anel 2.060 ESTABILIDADE MARSHALL RESISTENCIA À TRAÇÃO


K fluencia 0.254 CP 1 2 3 4 5 6 7
Altura
Diametro
Peso ao Ar (g) Fator
Peso ao Ar (Saturado, Sup. Seca)(g) Leitura
Peso na Água (4 minutos imerso) (g) R. T.
Vol. Do Corpo de Prova 0.00 LIMITES
Média PROJETO
Fator de correção 0.00 MÍNIMO MÁXIMO
Densidade Aparente 2.500
Densidade Teórica 0.000 2.632
% VAZIOS (MÉTODO DNER) 5.0% 3.0% 5.0%
% V. C. B. (MÉTODO SUPERPAVE) 11.5%
% V. A M. (MÉTODO SUPERPAVE) 16.3% > 13,0% 15.0%
% R. B. V. 69.3% 65.0% 75.0%
Leitura do Deflectômetro
Estabilidade Encontrada (kg)
Estabilidade Corrigida (kg) 1,052 > 700
Fluência, Leitura (mm) 11.0 8 16
OBSERVAÇÕES:

CONCLUSÃO DO ENSAIO:
PROBLEMAS NA GRANULOMETRIA - REFAZER ENSAIO COM NOVA AMOSTRA. PROBLEMAS NA M.E./ENSAIO RICE- REFAZER ENSAIO COM MESMA AMOSTRA.
#VALUE!
ENSAIO EXTRAÇÃO, GRANULOMETRIA E MARSHALL

Rodovia: SP- 328 Coleta: USINA 02 Trecho: Concessionária Via Paulista S/A Nº: MANHÃ
Km Inicial: USINA: Val Rocha Eng Projeto Mistura: Asfática a Quente ( MAQ ) Data Coleta: 05/05/23
Km Final: Amostra: Pedreira Jardinopólis Laboratorista: EQUIPE Data Ensaio: 05/05/23
Pista: NORTE FAIXA: 9 -SPV 16,0 Capa Rolamento Resp.pela Coleta: WELINGTON SOUZA Eng.Resp.: LEONARDO BERTELLI
CONTRATO: TIPO DE SERVIÇO: COLETA : 2ª CAMINHÃO

PESO DA EXTRAÇÃO DE BETUME DA AMOSTRA


PENEIRA 1,956.10 g FAIXA DE TRABALHO
AMOSTRA DESCRIÇĀO MUFA

E TO
Peso com Betume 2,081.30

OJ
PR
ASTM mm Peso acum. % retida % Passan. Min Max
Peso sem Betume 1,956.10
3/4" 19 12.30 0.6% 99.4% 99.8% 93% 100% Peso Betume 125.20
5/8" 16 66.90 3.4% 96.6% 95.5% 89% 100% % de Betume 6.02%
1/2" 12.7 332.6 17.0% 83.0% 81.7% 75% 89% Fator Correção Queima Mufa 1.10%
3/8" 9.5 555.0 28.4% 71.6% 68.4% 61% 75% Teor de betume adotado 4.92%
Nº 4 4.8 1,070.7 54.7% 45.3% 45.9% 41% 51%
Nº 10 2 1,485.7 76.0% 24.0% 28.6% 24% 34% ENSAIO DE MASSA ESPECIFICA MÁXIMA RICE)
Nº 40 0.59 1,755.8 89.8% 10.2% 12.1% 7% 17% Peso da amostra 2,528.8
Nº 80 0.18 1,807.0 92.4% 7.6% 9.1% 6.1% 12.1% Peso do frasco+agua 25oC 7,069.7
Nº 200 0.075 1,838.8 94.0% 6.0% 6.5% 4.5% 8.5% Peso frasco+agua+amostra 25oC 9,598.5
Frasco+agua+amostra vácuo 25oC 8,641.2
Volume (cm3) 957.3
M.E. Teor. (Rice) 2.642
9

2
1
100.0%
M.E.Ef. Mistura seca 2.873

EXTRAÇÃO NÃO CONFORME


80.0%

DADOS DO PROJETO
Teor de projeto 5.0%
60.0%
Dens. Real do CAP 1.033
M.E.SOLTA (RICE) 2.632
40.0% M.E.Ef. Mistura seca 2.867

20.0%

0.0%
0.07 0.7 7

MIX PROJETO FAIXA DE TRABALHO


FAIXA DE TRABALHO

Constante do anel 2.060 ESTABILIDADE MARSHALL RESISTENCIA À TRAÇÃO


K fluencia 0.254 CP 1 2 3 4 5 6 7
Altura
Diametro
Peso ao Ar (g) Fator
Peso ao Ar (Saturado, Sup. Seca)(g) Leitura
Peso na Água (4 minutos imerso) (g) R. T.
Vol. Do Corpo de Prova 0.00 LIMITES
Média PROJETO
Fator de correção 0.00 MÍNIMO MÁXIMO
Densidade Aparente 2.500
Densidade Teórica 0.000 2.632
% VAZIOS (MÉTODO DNER) 5.0% 3.0% 5.0%
% V. C. B. (MÉTODO SUPERPAVE) 11.5%
% V. A M. (MÉTODO SUPERPAVE) 16.3% > 13,0% 15.0%
% R. B. V. 69.3% 65.0% 75.0%
Leitura do Deflectômetro
Estabilidade Encontrada (kg)
Estabilidade Corrigida (kg) 1,052 > 700
Fluência, Leitura (mm) 11.0 8 16
OBSERVAÇÕES:

CONCLUSÃO DO ENSAIO:
PROBLEMAS NA M.E./ENSAIO RICE- REFAZER ENSAIO COM MESMA AMOSTRA.
#VALUE!
ENSAIO EXTRAÇÃO, GRANULOMETRIA E MARSHALL

Rodovia: SP- 328 Coleta: USINA 02 Trecho: Concessionária Via Paulista S/A Nº: MANHÃ
Km Inicial: USINA: Val Rocha Eng Projeto Mistura: Asfática a Quente ( MAQ ) Data Coleta: 28/04/23
Km Final: Amostra: Pedreira Jardinopólis Laboratorista: EQUIPE Data Ensaio: 28/04/23
Pista: NORTE FAIXA: 9 -SPV 16,0 Capa Rolamento Resp.pela Coleta: WELINGTON SOUZA Eng.Resp.: LEONARDO BERTELLI
CONTRATO: TIPO DE SERVIÇO: COLETA : 2ª CAMINHÃO

PESO DA EXTRAÇÃO DE BETUME DA AMOSTRA


PENEIRA 2,001.20 g FAIXA DE TRABALHO
AMOSTRA DESCRIÇĀO MUFA

E TO
Peso com Betume 2,133.10

OJ
PR
ASTM mm Peso acum. % retida % Passan. Min Max
Peso sem Betume 2,001.20
3/4" 19 0.00 0.0% 100% 99.8% 93% 100% Peso Betume 131.90
5/8" 16 89.40 4.5% 95.5% 95.5% 89% 100% % de Betume 6.18%
1/2" 12.7 327.4 16.4% 83.6% 81.7% 75% 89% Fator Correção Queima Mufa 1.30%
3/8" 9.5 545.0 27.2% 72.8% 68.4% 61% 75% Teor de betume adotado 4.88%
Nº 4 4.8 1,076.4 53.8% 46.2% 45.9% 41% 51%
Nº 10 2 1,515.4 75.7% 24.3% 28.6% 24% 34% ENSAIO DE MASSA ESPECIFICA MÁXIMA RICE)
Nº 40 0.59 1,806.8 90.3% 9.7% 12.1% 7% 17% Peso da amostra 1,943.8
Nº 80 0.18 1,862.5 93.1% 6.9% 9.1% 6.1% 12.1% Peso do frasco+agua 25oC 7,069.6
Nº 200 0.075 1,898.4 94.9% 5.1% 6.5% 4.5% 8.5% Peso frasco+agua+amostra 25oC 9,013.4
Frasco+agua+amostra vácuo 25oC 8,268.9
Volume (cm3) 744.5
M.E. Teor. (Rice) 2.611
9

2
1
100%
M.E.Ef. Mistura seca 2.833

EXTRAÇÃO NÃO CONFORME


80%

DADOS DO PROJETO
Teor de projeto 5.0%
60%
Dens. Real do CAP 1.033
M.E.SOLTA (RICE) 2.632
40% M.E.Ef. Mistura seca 2.867

20%

0%
0.07 0.7 7

MIX PROJETO FAIXA DE TRABALHO


FAIXA DE TRABALHO

Constante do anel 2.060 ESTABILIDADE MARSHALL RESISTENCIA À TRAÇÃO


K fluencia 0.254 CP 1 2 3 4 5 6 7
Altura
Diametro
Peso ao Ar (g) Fator
Peso ao Ar (Saturado, Sup. Seca)(g) Leitura
Peso na Água (4 minutos imerso) (g) R. T.
Vol. Do Corpo de Prova 0.00 LIMITES
Média PROJETO
Fator de correção 0.00 MÍNIMO MÁXIMO
Densidade Aparente 2.500
Densidade Teórica 0.000 2.632
% VAZIOS (MÉTODO DNER) 5.0% 3.0% 5.0%
% V. C. B. (MÉTODO SUPERPAVE) 11.5%
% V. A M. (MÉTODO SUPERPAVE) 16.3% > 13,0% 15.0%
% R. B. V. 69.3% 65.0% 75.0%
Leitura do Deflectômetro
Estabilidade Encontrada (kg)
Estabilidade Corrigida (kg) 1,052 > 700
Fluência, Leitura (mm) 11.0 8 16
OBSERVAÇÕES:

CONCLUSÃO DO ENSAIO:
PROBLEMAS NA GRANULOMETRIA - REFAZER ENSAIO COM NOVA AMOSTRA. PROBLEMAS NA M.E./ENSAIO RICE- REFAZER ENSAIO COM MESMA AMOSTRA.
#VALUE!
ENSAIO EXTRAÇÃO, GRANULOMETRIA E MARSHALL

Rodovia: SP- 328 Coleta: USINA 02 Trecho: Concessionária Via Paulista S/A Nº:
Km Inicial: USINA: Val Rocha Eng Projeto Mistura: Asfática a Quente ( MAQ ) Data Coleta:
Km Final: Amostra: Pedreira Jardinopólis Laboratorista: EQUIPE Data Ensaio: 30/12/99
Pista: NORTE FAIXA: 9 -SPV 16,0 Capa Rolamento Resp.pela Coleta: WELINGTON SOUZA Eng.Resp.: LEONARDO BERTELLI
CONTRATO: TIPO DE SERVIÇO: COLETA : CAMINHÃO

PESO DA EXTRAÇÃO DE BETUME DA AMOSTRA


PENEIRA 1,707.1 g FAIXA DE TRABALHO
AMOSTRA DESCRIÇĀO MUFA

E TO
Pêso do cesto 2,961.4

OJ
PR
ASTM mm Peso acum. % retida % Passan. Min Max
Pêso do cesto + Amostra c/ Betume 4,785.3
3/4" 19 0.0% 100% 93% 100% Pêso Amostra c/ Betume 1,823.9
5/8" 16 0.0% 96% 89% 100% Pêso do Cesto + Amostra s/ Betume 4,668.5
1/2" 12.7 0.0% 82% 75% 89% Pêso da Amostra s/ Betume 1,707.1
3/8" 9.5 0.0% 68% 61% 75% Pêso de betume extraido 116.8
Nº 4 4.8 0.0% 46% 41% 51% TEOR DE BETUME 6.40
Nº 10 2.00 29% 24% 34% Fator Correção Queima Mufa 1.30
Nº 40 0.59 12% 7% 17% TE0R DE BETUME C/CORREÇÃO 5.10
Nº 80 0.18 0.0% 9% 6.1% 12.1% ENSAIO DE MASSA ESPECIFICA MÁXIMA RICE)
Nº 200 0.075 0.0% 7% 4.5% 8.5% Peso da amostra 2,505.0
0.0% Peso do frasco+agua 25oC 7,069.8
0.0% Peso frasco+agua+amostra 25oC 9,574.8
Frasco+agua+amostra vácuo 25oC 8,621.0
Volume (cm3) 953.8
M.E. Teor. (Rice) 2.626
M.E.Ef. Mistura seca 1.028

EXTRAÇÃO NÃO CONFORME


DADOS DO PROJETO
Teor de projeto 5.0%
Dens. Real do CAP 1.033
M.E.SOLTA (RICE) 2.632
M.E.Ef. Mistura seca 2.867

Constante do anel 2.060 ESTABILIDADE MARSHALL RESISTENCIA À TRAÇÃO


K fluencia 0.254 CP 1 2 3 4 5 6 7
Altura
Diametro
Peso ao Ar (g) Fator
Peso ao Ar (Saturado, Sup. Seca)(g) Leitura
Peso na Água (4 minutos imerso) (g) R. T.
Vol. Do Corpo de Prova 0.00 LIMITES
Média PROJETO
Fator de correção 0.00 MÍNIMO MÁXIMO
Densidade Aparente 2.500
Densidade Teórica 0.000 2.632
% VAZIOS (MÉTODO DNER) 5.0% 3.0% 5.0%
% V. C. B. (MÉTODO SUPERPAVE) 11.5%
% V. A M. (MÉTODO SUPERPAVE) 16.3% > 13,0% 15.0%
% R. B. V. 69.3% 65.0% 75.0%
Leitura do Deflectômetro
Estabilidade Encontrada (kg)
Estabilidade Corrigida (kg) 1,052 > 700
Fluência, Leitura (mm) 11.0 8 16
OBSERVAÇÕES:

CONCLUSÃO DO ENSAIO:
PROBLEMAS NA GRANULOMETRIA - REFAZER ENSAIO COM NOVA AMOSTRA. PROBLEMAS NA M.E./ENSAIO RICE- REFAZER ENSAIO COM MESMA AMOSTRA.
#VALUE!
ENSAIO EXTRAÇÃO, GRANULOMETRIA E MARSHALL

Rodovia: SP- 328 Coleta: USINA 02 Trecho: Concessionária Via Paulista S/A Nº:
Km Inicial: USINA: Val Rocha Eng Projeto Mistura: Asfática a Quente ( MAQ ) Data Coleta:
Km Final: Amostra: Pedreira Jardinopólis Laboratorista: EQUIPE Data Ensaio: 30/12/99
Pista: NORTE FAIXA: 9 -SPV 16,0 Capa Rolamento Resp.pela Coleta: WELINGTON SOUZA Eng.Resp.: LEONARDO BERTELLI
CONTRATO: TIPO DE SERVIÇO: COLETA : CAMINHÃO

PESO DA EXTRAÇÃO DE BETUME DA AMOSTRA


PENEIRA 0.0 g FAIXA DE TRABALHO
AMOSTRA DESCRIÇĀO MUFA

E TO
Pêso do cesto

OJ
PR
ASTM mm Peso acum. % retida % Passan. Min Max
Pêso do cesto + Amostra c/ Betume
3/4" 19 100% 93% 100% Pêso Amostra c/ Betume
5/8" 16 96% 89% 100% Pêso do Cesto + Amostra s/ Betume
1/2" 12.7 82% 75% 89% Pêso da Amostra s/ Betume
3/8" 9.5 68% 61% 75% Pêso de betume extraido
Nº 4 4.8 46% 41% 51% TEOR DE BETUME
Nº 10 2.00 29% 24% 34% Fator Correção Queima Mufa
Nº 40 0.59 12% 7% 17% TE0R DE BETUME C/CORREÇÃO
Nº 80 0.18 9% 6.1% 12.1% ENSAIO DE MASSA ESPECIFICA MÁXIMA RICE)
Nº 200 0.075 7% 4.5% 8.5% Peso da amostra
Peso do frasco+agua 25oC
Peso frasco+agua+amostra 25oC
Frasco+agua+amostra vácuo 25oC
Volume (cm3)
M.E. Teor. (Rice)
M.E.Ef. Mistura seca

EXTRAÇÃO CONFORME
DADOS DO PROJETO
Teor de projeto 5.0%
Dens. Real do CAP 1.033
M.E.SOLTA (RICE) 2.632
M.E.Ef. Mistura seca 2.867

Constante do anel 1.799 ESTABILIDADE MARSHALL RESISTENCIA À TRAÇÃO


K fluencia 0.254 CP 1 2 3 4 5 6 7
Altura
Diametro
Peso ao Ar (g) Fator
Peso ao Ar (Saturado, Sup. Seca)(g) Leitura
Peso na Água (4 minutos imerso) (g) R. T.
Vol. Do Corpo de Prova 0.00 LIMITES
Média PROJETO
Fator de correção 0.00 MÍNIMO MÁXIMO
Densidade Aparente 2.500
Densidade Teórica 0.000 2.632
% VAZIOS (MÉTODO DNER) 5.0% 3.0% 5.0%
% V. C. B. (MÉTODO SUPERPAVE)
% V. A M. (MÉTODO SUPERPAVE) 16.3% > 13,0% 15.0%
% R. B. V. 69.3% 65.0% 75.0%
Leitura do Deflectômetro
Estabilidade Encontrada (kg)
Resistência a Tração Indireta a 25°C (Mpa) 1.1
Deformação do cp MAQ a 25°C (m.m) 5.6
OBSERVAÇÕES:

LABORATORISTA : FISCAL :
ENSAIO EXTRAÇÃO, GRANULOMETRIA E MARSHALL

Rodovia: SP- 328 Coleta: USINA 02 Trecho: Concessionária Via Paulista S/A Nº:
Km Inicial: USINA: Val Rocha Eng Projeto Mistura: Asfática a Quente ( MAQ ) Data Coleta:
Km Final: Amostra: Pedreira Jardinopólis Laboratorista: EQUIPE Data Ensaio: 30/12/99
Pista: NORTE FAIXA: 9 -SPV 16,0 Capa Rolamento Resp.pela Coleta: WELINGTON SOUZA Eng.Resp.: LEONARDO BERTELLI
CONTRATO: TIPO DE SERVIÇO: COLETA : CAMINHÃO

PESO DA EXTRAÇÃO DE BETUME DA AMOSTRA


PENEIRA 0.0 g FAIXA DE TRABALHO
AMOSTRA DESCRIÇĀO MUFA

E TO
Pêso do cesto

OJ
PR
ASTM mm Peso acum. % retida % Passan. Min Max
Pêso do cesto + Amostra c/ Betume
3/4" 19 100% 93% 100% Pêso Amostra c/ Betume
5/8" 16 96% 89% 100% Pêso do Cesto + Amostra s/ Betume
1/2" 12.7 82% 75% 89% Pêso da Amostra s/ Betume
3/8" 9.5 68% 61% 75% Pêso de betume extraido
Nº 4 4.8 46% 41% 51% TEOR DE BETUME
Nº 10 2.00 29% 24% 34% Fator Correção Queima Mufa
Nº 40 0.59 12% 7% 17% TE0R DE BETUME C/CORREÇÃO
Nº 80 0.18 9% 6.1% 12.1% ENSAIO DE MASSA ESPECIFICA MÁXIMA RICE)
Nº 200 0.075 7% 4.5% 8.5% Peso da amostra
Peso do frasco+agua 25oC
Peso frasco+agua+amostra 25oC
Frasco+agua+amostra vácuo 25oC
Volume (cm3)
M.E. Teor. (Rice)
M.E.Ef. Mistura seca

EXTRAÇÃO CONFORME
DADOS DO PROJETO
Teor de projeto 5.0%
Dens. Real do CAP 1.033
M.E.SOLTA (RICE) 2.632
M.E.Ef. Mistura seca 2.867

Constante do anel 1.799 ESTABILIDADE MARSHALL RESISTENCIA À TRAÇÃO


K fluencia 0.254 CP 1 2 3 4 5 6 7
Altura
Diametro
Peso ao Ar (g) Fator
Peso ao Ar (Saturado, Sup. Seca)(g) Leitura
Peso na Água (4 minutos imerso) (g) R. T.
Vol. Do Corpo de Prova 0.00 LIMITES
Média PROJETO
Fator de correção 0.00 MÍNIMO MÁXIMO
Densidade Aparente 2.500
Densidade Teórica 0.000 2.632
% VAZIOS (MÉTODO DNER) 5.0% 3.0% 5.0%
% V. C. B. (MÉTODO SUPERPAVE)
% V. A M. (MÉTODO SUPERPAVE) 16.3% > 13,0% 15.0%
% R. B. V. 69.3% 65.0% 75.0%
Leitura do Deflectômetro
Estabilidade Encontrada (kg)
Resistência a Tração Indireta a 25°C (Mpa) 1.1
Deformação do cp MAQ a 25°C (m.m) 5.6
OBSERVAÇÕES:

LABORATORISTA : FISCAL :
ENSAIO EXTRAÇÃO, GRANULOMETRIA E MARSHALL

Rodovia: SP- 330 Coleta: USINA - 02 Trecho: EMPREITEIRA KAPA Nº: 13 MANHÃ
Km Inicial: USINA: VAL ROCHA ENG.Projeto Mistura: 30/45 Data Coleta: 07/03/23
Km Final: Amostra: CAUQ Laboratorista: WELINGTON SOUZA Data Ensaio: 07/03/23
Pista: ANHANGUERA FAIXA 9 / 16mm Resp.pela Coleta: WELINGTON SOUZA Eng.Resp.: LEONARDO BERTELLI
CONTRATO: TIPO DE SERVIÇO:

PESO DA EXTRAÇÃO DE BETUME DA AMOSTRA


PENEIRA 1,932.40 g FAIXA DE TRABALHO
AMOSTRA DESCRIÇĀO SOXLET ROTAREX

E TO
Peso com Betume 1,693.00 2,026.80

OJ
PR
ASTM mm Peso acum. % retida % Passan. Min Max
Peso sem Betume 1,614.40 1,932.40
1" 25 0.00 0.0% 100% 100.0% 100% 100%
3/4" 19 9.20 0.5% 99.5% 99.8% 93% 100% Peso Betume 78.60 94.40
5/8" 16 111.10 5.7% 94% 95.5% 89% 100% % de Betume 4.45% 4.66%
1/2" 12.7 416.8 21.6% 78.4% 81.7% 75% 89% FATOR DE CORREÇĀO ROTAREX 0.19%
3/8" 9.5 665.6 34.4% 65.6% 68.4% 61% 75% Teor de betume adotado 4.47%
Nº 4 4.8 1,090.6 56.4% 43.6% 45.9% 41% 51%
Nº 10 2 1,400.9 72.5% 27.5% 28.6% 24% 34% ENSAIO DE MASSA ESPECIFICA MÁXIMA RICE)
Nº 40 0.59 1,717.8 88.9% 11.1% 12.1% 7% 17% Peso da amostra 1,943.8
Nº 80 0.18 1,766.1 91.4% 8.6% 9.1% 6% 12% Peso do frasco+agua 25oC 7,069.6
Nº 200 0.075 1,818.3 94.1% 5.9% 6.5% 5% 9% Peso frasco+agua+amostra 25oC 9,013.4
Frasco+agua+amostra vácuo 25oC 8,268.9
Volume (cm3) 744.5
M.E. Teor. (Rice) -24.416
9

2
1
100%
M.E.Ef. Mistura seca -10.910

EXTRAÇÃO CONFORME
80%

DADOS DO PROJETO
Teor de projeto 4.5%
60%
Dens. Real do CAP 1.003
M.E.SOLTA (RICE) 2.651
40% M.E.Ef. Mistura seca 2.874

20%

0%
0.07 0.7 7

MIX PROJETO FAIXA DE TRABALHO


FAIXA DE TRABALHO

Constante do anel 2.060 ESTABILIDADE MARSHALL RESISTENCIA À TRAÇÃO


K fluencia 0.254 CP 1 2 3 4 5 6 7
Altura 5.94 5.91 5.87
Diametro 10.15 10.16 10.14
Peso ao Ar (g) 1,187.38 1,188.24 1,189.23 Fator 1.12 1.13 1.14
Peso ao Ar (Saturado, Sup. Seca)(g) 1,189.12 1,190.85 1,191.45 Leitura 628 622 615
Peso na Água (4 minutos imerso) (g) 722.17 722.67 723.98 R. T. 1.53 1.54 1.55
Vol. Do Corpo de Prova 466.95 468.18 467.47 0.00 LIMITES
Média PROJETO
Fator de correção 1.18 1.18 1.18 0.00 MÍNIMO MÁXIMO
Densidade Aparente 2.543 2.538 2.544 2.542 2.546
Densidade Teórica -24.416 -24.416 -24.416 0.000 -24.416 2.651
% VAZIOS (MÉTODO SUPERPAVE) 110.41% 110.39% 110.42% 110.4% 4.0% 3.0% 5.0%
% V. C. B. (MÉTODO SUPERPAVE) 11.8% 11.8% 11.8% 11.8% 11.4%
% V. A M. (MÉTODO SUPERPAVE) 15.6% 15.8% 15.6% 15.7% 15.0% > 13,0%
% R. B. V. -605.8% -598.5% -607.5% -604.0% 74.6% 65.0% 80.0%
Leitura do Deflectômetro 628 622 615 622
Estabilidade Encontrada (kg) 1,294 1,281 1,267 1,281
Estabilidade Corrigida (kg) 1,528 1,513 1,496 1,513 1,545 > 700
Fluência, Leitura (mm) 9.95 10.00 10.14 10.03 10.0 8 16
OBSERVAÇÕES:

CONCLUSÃO DO ENSAIO:
PROBLEMAS NA M.E./ENSAIO RICE- REFAZER ENSAIO COM MESMA AMOSTRA.
RELAÇÃO ESTAB. / FLUENCIA(MIN = 230 mm) = 151mm = > REVER PROJETO - MASSA INSTÁVEL
ENSAIO EXTRAÇÃO, GRANULOMETRIA E MARSHALL

Rodovia: SPA 318/330 Coleta: USINA 02 Trecho: Concessionária Via Paulista S/A Nº:
Km Inicial: USINA: Val Rocha Eng Projeto Mistura: Asfática a Quente ( MAQ ) Data Coleta:
Km Final: Amostra: Pedreira Jardinopólis Laboratorista: EQUIPE Data Ensaio: 30/12/99
Pista: NORTE FAIXA: 9,5 -GAP GRADED Capa Rolamento Resp.pela Coleta: WELINGTON SOUZA Eng.Resp.: LEONARDO BERTELLI
CONTRATO: TIPO DE SERVIÇO: COLETA : CAMINHÃO

EXTRAÇÃO DE BETUME DA AMOSTRA


PENEIRA PESO DA AMOSTRA 0.0 g FAIXA DE TRABALHO
DESCRIÇĀO MUFA

O
ET
Pêso do cesto

OJ
PR
ASTM mm Peso acum. % retida % Passan. Min Max
Pêso do cesto + Amostra c/ Betume
1" 25 100% 100% 100% Pêso Amostra c/ Betume
3/4" 19 100% 100% 100% Pêso do Cesto + Amostra s/ Betume
1/2" 12.7 100% 100% 100% Pêso da Amostra s/ Betume
3/8" 9.5 99% 92% 100% Pêso de betume extraido
Nº 4 4.8 45% 40% 50% TEOR DE BETUME
Nº 10 2.00 24% 19% 29% Fator Correção Queima Mufa
Nº 40 0.59 10% 5% 15% TE0R DE BETUME C/CORREÇÃO
Nº 80 0.18 8% 5% 11% ENSAIO DE MASSA ESPECIFICA MÁXIMA RICE)
Nº 200 0.075 6% 4% 8% Peso da amostra
Peso do frasco+agua 25oC
Peso frasco+agua+amostra 25oC
Frasco+agua+amostra vácuo 25oC
Volume (cm3)
M.E. Teor. (Rice)
M.E.Ef. Mistura seca

EXTRAÇÃO CONFORME
DADOS DO PROJETO
Teor de projeto 5.8%
Dens. Real do CAP 1.033
M.E.SOLTA (RICE) 2.593
M.E.Ef. Mistura seca 2.859

Constante do anel 1.799 ESTABILIDADE MARSHALL RESISTENCIA À TRAÇÃO


K fluencia 0.254 CP 1 2 3 4 5 6 7
Altura
Diametro
Peso ao Ar (g) Fator
Peso ao Ar (Saturado, Sup. Seca)(g) Leitura
Peso na Água (4 minutos imerso) (g) R. T.
Vol. Do Corpo de Prova 0.00 LIMITES
Média PROJETO
Fator de correção 0.00 MÍNIMO MÁXIMO
Densidade Aparente 2.489
Densidade Teórica 0.000 2.593
% VAZIOS (MÉTODO DNER) 4.0% 3.0% 5.0%
% V. C. B. (MÉTODO SUPERPAVE)
% V. A M. (MÉTODO SUPERPAVE) 17.2% > 16,0% 18.0%
% R. B. V. 76,7,% 65.0% 80.0%
Leitura do Deflectômetro
Estabilidade Encontrada (kg)
Resistência a Tração Indireta a 25°C (Mpa) 0.6
Deformação do cp MAQ a 25°C (m.m) 7.2
OBSERVAÇÕES:

LABORATORISTA : FISCAL :
ENSAIO EXTRAÇÃO, GRANULOMETRIA E MARSHALL

Rodovia: SP- 330 Coleta: USINA - 02 Trecho: EMPREITEIRA KAPA Nº: 14 MANHÃ
Km Inicial: USINA: VAL ROCHA ENG.Projeto Mistura: 30/45 Data Coleta: 08/03/23
Km Final: Amostra: CAUQ Laboratorista: WELINGTON SOUZA Data Ensaio: 08/03/23
Pista: ANHANGUERA FAIXA 9 / 16mm Resp.pela Coleta: WELINGTON SOUZA Eng.Resp.: LEONARDO BERTELLI
CONTRATO: TIPO DE SERVIÇO:

PESO DA EXTRAÇÃO DE BETUME DA AMOSTRA


PENEIRA 1,932.30 g FAIXA DE TRABALHO
AMOSTRA DESCRIÇĀO SOXLET MUFA

E TO
Peso com Betume 1,374.90 2,024.96

OJ
PR
ASTM mm Peso acum. % retida % Passan. Min Max
Peso sem Betume 1,310.70 1,932.30
1" 25 0.00 0.0% 100% 100.0% 100% 100%
3/4" 19 0.00 0.0% 100.0% 99.8% 93% 100% Peso Betume 64.20 92.66
5/8" 16 69.60 3.6% 96% 95.5% 89% 100% % de Betume 4.67% 4.58%
1/2" 12.7 322.7 16.7% 83.3% 81.7% 75% 89% FATOR DE CORREÇĀO ROTAREX
3/8" 9.5 620.3 32.1% 67.9% 68.4% 61% 75% Teor de betume adotado 4.58%
Nº 4 4.8 1,076.3 55.7% 44.3% 45.9% 41% 51%
Nº 10 2 1,360.3 70.4% 29.6% 28.6% 24% 34% ENSAIO DE MASSA ESPECIFICA MÁXIMA RICE)
Nº 40 0.59 1,673.4 86.6% 13.4% 12.1% 7% 17% Peso da amostra 1,912.8
Nº 80 0.18 1,760.3 91.1% 8.9% 9.1% 6% 12% Peso do frasco+agua 25oC 7,072.4
Nº 200 0.075 1,793.2 92.8% 7.2% 6.5% 5% 9% Peso frasco+agua+amostra 25oC 8,991.0
Frasco+agua+amostra vácuo 25oC 8,268.9
Volume (cm3) 722.1
M.E. Teor. (Rice) 722.100
9

2
1
100%
M.E.Ef. Mistura seca -21.571

EXTRAÇÃO CONFORME
80%

DADOS DO PROJETO
Teor de projeto 4.5%
60%
Dens. Real do CAP 1.003
M.E.SOLTA (RICE) 2.651
40% M.E.Ef. Mistura seca 2.874

20%

0%
0.07 0.7 7

MIX PROJETO FAIXA DE TRABALHO


FAIXA DE TRABALHO

Constante do anel 2.060 ESTABILIDADE MARSHALL RESISTENCIA À TRAÇÃO


K fluencia 0.254 CP 1 2 3 4 5 6 7
Altura 5.94 5.91 5.87
Diametro 10.13 10.14 10.11
Peso ao Ar (g) 1,188.45 1,189.29 1,190.33 Fator 1.12 1.13 1.14
Peso ao Ar (Saturado, Sup. Seca)(g) 1,190.56 1,191.35 1,192.40 Leitura 626 620 618
Peso na Água (4 minutos imerso) (g) 723.67 723.97 723.98 R. T. 1.53 1.53 1.56
Vol. Do Corpo de Prova 466.89 467.38 468.42 0.00 LIMITES
Média PROJETO
Fator de correção 1.18 1.18 1.17 0.00 MÍNIMO MÁXIMO
Densidade Aparente 2.545 2.545 2.541 2.544 2.546
Densidade Teórica 722.100 722.100 722.100 0.000 722.100 2.651
% VAZIOS (MÉTODO SUPERPAVE) 99.65% 99.65% 99.65% 99.6% 4.0% 3.0% 5.0%
% V. C. B. (MÉTODO SUPERPAVE) 11.6% 11.6% 11.6% 11.6% 11.4%
% V. A M. (MÉTODO SUPERPAVE) 15.5% 15.5% 15.6% 15.5% 15.0% > 13,0%
% R. B. V. -543.5% -542.3% -537.7% -541.2% 74.6% 65.0% 80.0%
Leitura do Deflectômetro 626 620 618 621
Estabilidade Encontrada (kg) 1,290 1,277 1,273 1,280
Estabilidade Corrigida (kg) 1,523 1,509 1,504 1,512 1,545 > 700
Fluência, Leitura (mm) 9.92 9.97 10.19 10.03 10.0 8 16
OBSERVAÇÕES:

CONCLUSÃO DO ENSAIO:
PROBLEMAS NA M.E./ENSAIO RICE- REFAZER ENSAIO COM MESMA AMOSTRA.
RELAÇÃO ESTAB. / FLUENCIA(MIN = 230 mm) = 151mm = > REVER PROJETO - MASSA INSTÁVEL
ENSAIO EXTRAÇÃO, GRANULOMETRIA E MARSHALL

Rodovia: SP- 330 Coleta: USINA - 02 Trecho: EMPREITEIRA KAPA Nº: 15 MANHÃ
Km Inicial: USINA: VAL ROCHA ENG.Projeto Mistura: 30/45 Data Coleta: 09/03/23
Km Final: Amostra: CAUQ Laboratorista: WELINGTON SOUZA Data Ensaio: 09/03/23
Pista: ANHANGUERA FAIXA 9 / 16mm Resp.pela Coleta: WELINGTON SOUZA Eng.Resp.: LEONARDO BERTELLI
CONTRATO: TIPO DE SERVIÇO:

PESO DA EXTRAÇÃO DE BETUME DA AMOSTRA


PENEIRA 1,553.50 g FAIXA DE TRABALHO
AMOSTRA DESCRIÇĀO SOXLET MUFA

E TO
Peso com Betume 1,372.90 1,628.78

OJ
PR
ASTM mm Peso acum. % retida % Passan. Min Max
Peso sem Betume 1,309.60 1,553.50
1" 25 0.00 0.0% 100% 100.0% 100% 100%
3/4" 19 0.00 0.0% 100.0% 99.8% 93% 100% Peso Betume 63.30 75.28
5/8" 16 65.60 4.2% 95.8% 95.5% 89% 100% % de Betume 4.61% 4.62%
1/2" 12.7 284.8 18.3% 81.7% 81.7% 75% 89% FATOR DE CORREÇĀO ROTAREX
3/8" 9.5 492.1 31.7% 68.3% 68.4% 61% 75% Teor de betume adotado 4.62%
Nº 4 4.8 813.5 52.4% 47.6% 45.9% 41% 51%
Nº 10 2 1,158.2 74.6% 25.4% 28.6% 24% 34% ENSAIO DE MASSA ESPECIFICA MÁXIMA RICE)
Nº 40 0.59 1,381.3 88.9% 11.1% 12.1% 7% 17% Peso da amostra 1,932.8
Nº 80 0.18 1,428.8 92.0% 8.0% 9.1% 6% 12% Peso do frasco+agua 25oC 7,072.1
Nº 200 0.075 1,459.6 94.0% 6.0% 6.5% 5% 9% Peso frasco+agua+amostra 25oC 9,004.9
Frasco+agua+amostra vácuo 25oC 8,274.5
Volume (cm3) 730.4
M.E. Teor. (Rice) 730.400
9

2
1
100%
M.E.Ef. Mistura seca -21.332

EXTRAÇÃO CONFORME
80%

DADOS DO PROJETO
Teor de projeto 4.5%
60%
Dens. Real do CAP 1.003
M.E.SOLTA (RICE) 2.651
40% M.E.Ef. Mistura seca 2.874

20%

0%
0.07 0.7 7

MIX PROJETO FAIXA DE TRABALHO


FAIXA DE TRABALHO

Constante do anel 2.060 ESTABILIDADE MARSHALL RESISTENCIA À TRAÇÃO


K fluencia 0.254 CP 1 2 3 4 5 6 7
Altura 5.96 6.01 5.89
Diametro 10.11 10.12 10.13
Peso ao Ar (g) 1,186.19 1,181.37 1,180.39 Fator 1.12 1.10 1.14
Peso ao Ar (Saturado, Sup. Seca)(g) 1,188.26 1,183.44 1,182.46 Leitura 635 646 619
Peso na Água (4 minutos imerso) (g) 721.67 720.57 719.21 R. T. 1.55 1.53 1.55
Vol. Do Corpo de Prova 466.59 462.87 463.25 0.00 LIMITES
Média PROJETO
Fator de correção 1.18 1.20 1.20 0.00 MÍNIMO MÁXIMO
Densidade Aparente 2.542 2.552 2.548 2.548 2.546
Densidade Teórica 730.400 730.400 730.400 0.000 730.400 2.651
% VAZIOS (MÉTODO SUPERPAVE) 99.65% 99.65% 99.65% 99.7% 4.0% 3.0% 5.0%
% V. C. B. (MÉTODO SUPERPAVE) 11.7% 11.8% 11.7% 11.7% 11.4%
% V. A M. (MÉTODO SUPERPAVE) 15.6% 15.3% 15.4% 15.5% 15.0% > 13,0%
% R. B. V. -537.5% -551.4% -545.5% -544.8% 74.6% 65.0% 80.0%
Leitura do Deflectômetro 635 646 619 633
Estabilidade Encontrada (kg) 1,308 1,331 1,275 1,305
Estabilidade Corrigida (kg) 1,547 1,574 1,508 1,543 1,545 > 700
Fluência, Leitura (mm) 9.95 9.99 10.15 10.03 10.0 8 16
OBSERVAÇÕES:

CONCLUSÃO DO ENSAIO:
PROBLEMAS NA M.E./ENSAIO RICE- REFAZER ENSAIO COM MESMA AMOSTRA.
RELAÇÃO ESTAB. / FLUENCIA(MIN = 230 mm) = 154mm = > REVER PROJETO - MASSA INSTÁVEL
ENSAIO EXTRAÇÃO, GRANULOMETRIA E MARSHALL

Rodovia: SP- 330 Coleta: USINA - 02 Trecho: EMPREITEIRA KAPA Nº: 16 MANHÃ
Km Inicial: USINA: VAL ROCHA ENG.Projeto Mistura: 30/45 Data Coleta: 10/03/23
Km Final: Amostra: CAUQ Laboratorista: WELINGTON SOUZA Data Ensaio: 10/03/23
Pista: ANHANGUERA FAIXA 9 / 16mm Resp.pela Coleta: WELINGTON SOUZA Eng.Resp.: LEONARDO BERTELLI
CONTRATO: TIPO DE SERVIÇO:

PESO DA EXTRAÇÃO DE BETUME DA AMOSTRA


PENEIRA 1,476.00 g FAIXA DE TRABALHO
AMOSTRA DESCRIÇĀO SOXLET MUFA

E TO
Peso com Betume 1,374.03 1,547.09

OJ
PR
ASTM mm Peso acum. % retida % Passan. Min Max
Peso sem Betume 1,311.67 1,476.00
1" 25 0.00 0.0% 100% 100.0% 100% 100%
3/4" 19 0.00 0.0% 100.0% 99.8% 93% 100% Peso Betume 62.36 71.09
5/8" 16 49.00 3.3% 96.7% 95.5% 89% 100% % de Betume 4.54% 4.60%
1/2" 12.7 258.3 17.5% 82.5% 81.7% 75% 89% FATOR DE CORREÇĀO ROTAREX
3/8" 9.5 438.4 29.7% 70.3% 68.4% 61% 75% Teor de betume adotado 4.60%
Nº 4 4.8 767.5 52.0% 48.0% 45.9% 41% 51%
Nº 10 2 1,048.3 71.0% 29.0% 28.6% 24% 34% ENSAIO DE MASSA ESPECIFICA MÁXIMA RICE)
Nº 40 0.59 1,289.6 87.4% 12.6% 12.1% 7% 17% Peso da amostra 1,933.9
Nº 80 0.18 1,338.6 90.7% 9.3% 9.1% 6% 12% Peso do frasco+agua 25oC 7,072.5
Nº 200 0.075 1,373.2 93.0% 7.0% 6.5% 5% 9% Peso frasco+agua+amostra 25oC 9,006.4
Frasco+agua+amostra vácuo 25oC 8,275.7
Volume (cm3) 730.7
M.E. Teor. (Rice) 730.700
9

2
1
100%
M.E.Ef. Mistura seca -21.466

EXTRAÇÃO CONFORME
80%

DADOS DO PROJETO
Teor de projeto 4.5%
60%
Dens. Real do CAP 1.003
M.E.SOLTA (RICE) 2.651
40% M.E.Ef. Mistura seca 2.874

20%

0%
0.07 0.7 7

MIX PROJETO FAIXA DE TRABALHO


FAIXA DE TRABALHO

Constante do anel 2.060 ESTABILIDADE MARSHALL RESISTENCIA À TRAÇÃO


K fluencia 0.254 CP 1 2 3 4 5 6 7
Altura 5.96 6.00 5.89
Diametro 10.14 10.15 10.12
Peso ao Ar (g) 1,185.57 1,180.47 1,179.59 Fator 1.12 1.10 1.14
Peso ao Ar (Saturado, Sup. Seca)(g) 1,187.66 1,182.54 1,181.76 Leitura 634 645 618
Peso na Água (4 minutos imerso) (g) 720.65 719.51 718.33 R. T. 1.54 1.53 1.55
Vol. Do Corpo de Prova 467.01 463.03 463.43 0.00 LIMITES
Média PROJETO
Fator de correção 1.18 1.20 1.20 0.00 MÍNIMO MÁXIMO
Densidade Aparente 2.539 2.549 2.545 2.544 2.546
Densidade Teórica 730.700 730.700 730.700 0.000 730.700 2.651
% VAZIOS (MÉTODO SUPERPAVE) 99.65% 99.65% 99.65% 99.7% 4.0% 3.0% 5.0%
% V. C. B. (MÉTODO SUPERPAVE) 11.6% 11.7% 11.7% 11.7% 11.4%
% V. A M. (MÉTODO SUPERPAVE) 15.7% 15.4% 15.5% 15.5% 15.0% > 13,0%
% R. B. V. -533.6% -548.4% -542.7% -541.6% 74.6% 65.0% 80.0%
Leitura do Deflectômetro 634 645 618 632
Estabilidade Encontrada (kg) 1,306 1,329 1,273 1,303
Estabilidade Corrigida (kg) 1,542 1,569 1,503 1,538 1,545 > 700
Fluência, Leitura (mm) 9.93 9.94 10.19 10.02 10.0 8 16
OBSERVAÇÕES:

CONCLUSÃO DO ENSAIO:
PROBLEMAS NA M.E./ENSAIO RICE- REFAZER ENSAIO COM MESMA AMOSTRA.
RELAÇÃO ESTAB. / FLUENCIA(MIN = 230 mm) = 154mm = > REVER PROJETO - MASSA INSTÁVEL
ENSAIO EXTRAÇÃO, GRANULOMETRIA E MARSHALL

Rodovia: SP- 330 Coleta: USINA - 02 Trecho: EMPREITEIRA KAPA Nº: 17 MANHÃ
Km Inicial: USINA: VAL ROCHA ENG.Projeto Mistura: 30/45 Data Coleta: 18/03/23
Km Final: Amostra: CAUQ Laboratorista: WELINGTON SOUZA Data Ensaio: 18/03/23
Pista: ANHANGUERA FAIXA 9 / 16mm Resp.pela Coleta: WELINGTON SOUZA Eng.Resp.: LEONARDO BERTELLI
CONTRATO: TIPO DE SERVIÇO:

PESO DA EXTRAÇÃO DE BETUME DA AMOSTRA


PENEIRA 1,580.70 g FAIXA DE TRABALHO
AMOSTRA DESCRIÇĀO SOXLET MUFA

E TO
Peso com Betume 1,273.70 1,656.16

OJ
PR
ASTM mm Peso acum. % retida % Passan. Min Max
Peso sem Betume 1,216.20 1,580.70
1" 25 0.00 0.0% 100% 100.0% 100% 100%
3/4" 19 0.00 0.0% 100.0% 99.8% 93% 100% Peso Betume 57.50 75.46
5/8" 16 67.30 4.3% 95.7% 95.5% 89% 100% % de Betume 4.51% 4.56%
1/2" 12.7 372.8 23.6% 76.4% 81.7% 75% 89% FATOR DE CORREÇĀO ROTAREX
3/8" 9.5 608.5 38.5% 61.5% 68.4% 61% 75% Teor de betume adotado 4.56%
Nº 4 4.8 942.6 59.6% 40.4% 45.9% 41% 51%
Nº 10 2 1,148.7 72.7% 27.3% 28.6% 24% 34% ENSAIO DE MASSA ESPECIFICA MÁXIMA RICE)
Nº 40 0.59 1,403.7 88.8% 11.2% 12.1% 7% 17% Peso da amostra 1,912.1
Nº 80 0.18 1,455.4 92.1% 7.9% 9.1% 6% 12% Peso do frasco+agua 25oC 7,073.1
Nº 200 0.075 1,484.8 93.9% 6.1% 6.5% 5% 9% Peso frasco+agua+amostra 25oC 8,985.2
Frasco+agua+amostra vácuo 25oC 8,264.6
Volume (cm3) 720.6
M.E. Teor. (Rice) 720.600
9

2
1
100%
M.E.Ef. Mistura seca -21.672

EXTRAÇÃO CONFORME
80%

DADOS DO PROJETO
Teor de projeto 4.5%
60%
Dens. Real do CAP 1.003
M.E.SOLTA (RICE) 2.651
40% M.E.Ef. Mistura seca 2.874

20%

0%
0.07 0.7 7

MIX PROJETO FAIXA DE TRABALHO


FAIXA DE TRABALHO

Constante do anel 2.060 ESTABILIDADE MARSHALL RESISTENCIA À TRAÇÃO


K fluencia 0.254 CP 1 2 3 4 5 6 7
Altura 5.96 5.98 5.89
Diametro 10.14 10.15 10.14
Peso ao Ar (g) 1,184.47 1,179.38 1,178.53 Fator 1.12 1.11 1.14
Peso ao Ar (Saturado, Sup. Seca)(g) 1,186.58 1,181.44 1,180.65 Leitura 635 640 620
Peso na Água (4 minutos imerso) (g) 720.22 718.49 717.28 R. T. 1.54 1.54 1.55
Vol. Do Corpo de Prova 466.36 462.95 463.37 0.00 LIMITES
Média PROJETO
Fator de correção 1.18 1.20 1.20 0.00 MÍNIMO MÁXIMO
Densidade Aparente 2.540 2.548 2.543 2.544 2.546
Densidade Teórica 720.600 720.600 720.600 0.000 720.600 2.651
% VAZIOS (MÉTODO SUPERPAVE) 99.65% 99.65% 99.65% 99.6% 4.0% 3.0% 5.0%
% V. C. B. (MÉTODO SUPERPAVE) 11.5% 11.6% 11.6% 11.6% 11.4%
% V. A M. (MÉTODO SUPERPAVE) 15.7% 15.4% 15.5% 15.5% 15.0% > 13,0%
% R. B. V. -536.6% -547.1% -541.4% -541.7% 74.6% 65.0% 80.0%
Leitura do Deflectômetro 635 640 620 632
Estabilidade Encontrada (kg) 1,308 1,318 1,277 1,301
Estabilidade Corrigida (kg) 1,548 1,561 1,512 1,540 1,545 > 700
Fluência, Leitura (mm) 9.90 9.97 10.11 9.99 10.0 8 16
OBSERVAÇÕES:

CONCLUSÃO DO ENSAIO:
PROBLEMAS NA M.E./ENSAIO RICE- REFAZER ENSAIO COM MESMA AMOSTRA.
RELAÇÃO ESTAB. / FLUENCIA(MIN = 230 mm) = 154mm = > REVER PROJETO - MASSA INSTÁVEL
ENSAIO EXTRAÇÃO, GRANULOMETRIA E MARSHALL

Rodovia: SP- 330 Coleta: USINA - 02 Trecho: EMPREITEIRA KAPA Nº: 18 MANHÃ
Km Inicial: USINA: VAL ROCHA ENG.Projeto Mistura: 30/45 Data Coleta: 21/03/23
Km Final: Amostra: CAUQ Laboratorista: WELINGTON SOUZA Data Ensaio: 21/03/23
Pista: ANHANGUERA FAIXA 9 / 16mm Resp.pela Coleta: WELINGTON SOUZA Eng.Resp.: LEONARDO BERTELLI
CONTRATO: TIPO DE SERVIÇO:

PESO DA EXTRAÇÃO DE BETUME DA AMOSTRA


PENEIRA 1,514.00 g FAIXA DE TRABALHO
AMOSTRA DESCRIÇĀO SOXLET MUFA

E TO
Peso com Betume 1,238.38 1,587.35

OJ
PR
ASTM mm Peso acum. % retida % Passan. Min Max
Peso sem Betume 1,181.70 1,514.00
1" 25 0.00 0.0% 100% 100.0% 100% 100%
3/4" 19 0.00 0.0% 100.0% 99.8% 93% 100% Peso Betume 56.68 73.35
5/8" 16 77.60 5.1% 94.9% 95.5% 89% 100% % de Betume 4.58% 4.62%
1/2" 12.7 221.4 14.6% 85.4% 81.7% 75% 89% FATOR DE CORREÇĀO ROTAREX
3/8" 9.5 399.3 26.4% 73.6% 68.4% 61% 75% Teor de betume adotado 4.62%
Nº 4 4.8 781.2 51.6% 48.4% 45.9% 41% 51%
Nº 10 2 1,126.4 74.4% 25.6% 28.6% 24% 34% ENSAIO DE MASSA ESPECIFICA MÁXIMA RICE)
Nº 40 0.59 1,341.4 88.6% 11.4% 12.1% 7% 17% Peso da amostra 1,905.0
Nº 80 0.18 1,356.4 89.6% 10.4% 9.1% 6% 12% Peso do frasco+agua 25oC 7,072.5
Nº 200 0.075 1,411.0 93.2% 6.8% 6.5% 5% 9% Peso frasco+agua+amostra 25oC 8,977.5
Frasco+agua+amostra vácuo 25oC 8,258.9
Volume (cm3) 718.6
M.E. Teor. (Rice) 718.600
9

2
1
100%
M.E.Ef. Mistura seca -21.347

EXTRAÇÃO CONFORME
80%

DADOS DO PROJETO
Teor de projeto 4.5%
60%
Dens. Real do CAP 1.003
M.E.SOLTA (RICE) 2.651
40% M.E.Ef. Mistura seca 2.874

20%

0%
0.07 0.7 7

MIX PROJETO FAIXA DE TRABALHO


FAIXA DE TRABALHO

Constante do anel 2.060 ESTABILIDADE MARSHALL RESISTENCIA À TRAÇÃO


K fluencia 0.254 CP 1 2 3 4 5 6 7
Altura 5.97 5.99 5.91
Diametro 10.13 10.12 10.15
Peso ao Ar (g) 1,155.58 1,158.15 1,156.86 Fator 1.12 1.11 1.13
Peso ao Ar (Saturado, Sup. Seca)(g) 1,157.35 1,160.86 1,158.10 Leitura 638 642 625
Peso na Água (4 minutos imerso) (g) 702.85 703.97 704.26 R. T. 1.55 1.54 1.54
Vol. Do Corpo de Prova 454.50 456.89 453.84 0.00 LIMITES
Média PROJETO
Fator de correção 1.24 1.23 1.24 0.00 MÍNIMO MÁXIMO
Densidade Aparente 2.543 2.535 2.549 2.542 2.546
Densidade Teórica 718.600 718.600 718.600 0.000 718.600 2.651
% VAZIOS (MÉTODO SUPERPAVE) 99.65% 99.65% 99.65% 99.6% 4.0% 3.0% 5.0%
% V. C. B. (MÉTODO SUPERPAVE) 11.7% 11.7% 11.7% 11.7% 11.4%
% V. A M. (MÉTODO SUPERPAVE) 15.6% 15.9% 15.4% 15.6% 15.0% > 13,0%
% R. B. V. -537.9% -527.7% -546.8% -537.5% 74.6% 65.0% 80.0%
Leitura do Deflectômetro 638 642 625 635
Estabilidade Encontrada (kg) 1,314 1,323 1,288 1,308
Estabilidade Corrigida (kg) 1,626 1,636 1,593 1,619 1,545 > 700
Fluência, Leitura (mm) 9.95 10.05 10.07 10.02 10.0 8 16
OBSERVAÇÕES:

CONCLUSÃO DO ENSAIO:
PROBLEMAS NA M.E./ENSAIO RICE- REFAZER ENSAIO COM MESMA AMOSTRA.
RELAÇÃO ESTAB. / FLUENCIA(MIN = 230 mm) = 161mm = > REVER PROJETO - MASSA INSTÁVEL
ENSAIO EXTRAÇÃO, GRANULOMETRIA E MARSHALL

Rodovia: SP- 330 Coleta: USINA - 02 Trecho: EMPREITEIRA KAPA Nº: 19 MANHÃ
Km Inicial: USINA: VAL ROCHA ENG.Projeto Mistura: 30/45 Data Coleta: 22/03/23
Km Final: Amostra: CAUQ Laboratorista: WELINGTON SOUZA Data Ensaio: 22/03/23
Pista: ANHANGUERA FAIXA 9 / 16mm Resp.pela Coleta: WELINGTON SOUZA Eng.Resp.: LEONARDO BERTELLI
CONTRATO: TIPO DE SERVIÇO:

PESO DA EXTRAÇÃO DE BETUME DA AMOSTRA


PENEIRA 1,476.20 g FAIXA DE TRABALHO
AMOSTRA DESCRIÇĀO SOXLET MUFA

E TO
Peso com Betume 1,209.62 1,546.12

OJ
PR
ASTM mm Peso acum. % retida % Passan. Min Max
Peso sem Betume 1,155.11 1,476.20
1" 25 0.00 0.0% 100% 100.0% 100% 100%
3/4" 19 0.00 0.0% 100.0% 99.8% 93% 100% Peso Betume 54.51 69.92
5/8" 16 70.40 4.8% 95.2% 95.5% 89% 100% % de Betume 4.51% 4.52%
1/2" 12.7 245.7 16.6% 83.4% 81.7% 75% 89% FATOR DE CORREÇĀO ROTAREX
3/8" 9.5 491.6 33.3% 66.7% 68.4% 61% 75% Teor de betume adotado 4.52%
Nº 4 4.8 795.7 53.9% 46.1% 45.9% 41% 51%
Nº 10 2 1,064.3 72.1% 27.9% 28.6% 24% 34% ENSAIO DE MASSA ESPECIFICA MÁXIMA RICE)
Nº 40 0.59 1,300.5 88.1% 11.9% 12.1% 7% 17% Peso da amostra 2,076.0
Nº 80 0.18 1,346.3 91.2% 8.8% 9.1% 6% 12% Peso do frasco+agua 25oC 7,073.3
Nº 200 0.075 1,387.6 94.0% 6.0% 6.5% 5% 9% Peso frasco+agua+amostra 25oC 9,149.3
Frasco+agua+amostra vácuo 25oC 8,366.0
Volume (cm3) 783.3
M.E. Teor. (Rice) 783.300
9

2
1
100%
M.E.Ef. Mistura seca -21.793

EXTRAÇÃO CONFORME
80%

DADOS DO PROJETO
Teor de projeto 4.5%
60%
Dens. Real do CAP 1.003
M.E.SOLTA (RICE) 2.651
40% M.E.Ef. Mistura seca 2.874

20%

0%
0.07 0.7 7

MIX PROJETO FAIXA DE TRABALHO


FAIXA DE TRABALHO

Constante do anel 2.060 ESTABILIDADE MARSHALL RESISTENCIA À TRAÇÃO


K fluencia 0.254 CP 1 2 3 4 5 6 7
Altura 5.97 5.96 5.93
Diametro 10.14 10.15 10.12
Peso ao Ar (g) 1,156.62 1,159.21 1,157.56 Fator 1.12 1.12 1.12
Peso ao Ar (Saturado, Sup. Seca)(g) 1,158.77 1,161.34 1,159.63 Leitura 636 638 628
Peso na Água (4 minutos imerso) (g) 703.72 704.67 704.87 R. T. 1.54 1.55 1.54
Vol. Do Corpo de Prova 455.05 456.67 454.76 0.00 LIMITES
Média PROJETO
Fator de correção 1.23 1.23 1.24 0.00 MÍNIMO MÁXIMO
Densidade Aparente 2.542 2.538 2.545 2.542 2.546
Densidade Teórica 783.300 783.300 783.300 0.000 783.300 2.651
% VAZIOS (MÉTODO SUPERPAVE) 99.68% 99.68% 99.68% 99.7% 4.0% 3.0% 5.0%
% V. C. B. (MÉTODO SUPERPAVE) 11.5% 11.4% 11.5% 11.5% 11.4%
% V. A M. (MÉTODO SUPERPAVE) 15.6% 15.7% 15.4% 15.6% 15.0% > 13,0%
% R. B. V. -540.6% -536.0% -545.7% -540.8% 74.6% 65.0% 80.0%
Leitura do Deflectômetro 636 638 628 634
Estabilidade Encontrada (kg) 1,310 1,314 1,294 1,306
Estabilidade Corrigida (kg) 1,618 1,623 1,597 1,613 1,545 > 700
Fluência, Leitura (mm) 9.98 10.05 10.11 10.05 10.0 8 16
OBSERVAÇÕES:

CONCLUSÃO DO ENSAIO:
PROBLEMAS NA M.E./ENSAIO RICE- REFAZER ENSAIO COM MESMA AMOSTRA.
RELAÇÃO ESTAB. / FLUENCIA(MIN = 230 mm) = 161mm = > REVER PROJETO - MASSA INSTÁVEL
ENSAIO EXTRAÇÃO, GRANULOMETRIA E MARSHALL

Rodovia: SP- 330 Coleta: USINA - 02 Trecho: EMPREITEIRA KAPA Nº: 20 MANHÃ
Km Inicial: USINA: VAL ROCHA ENG.Projeto Mistura: 30/45 Data Coleta: 23/03/23
Km Final: Amostra: CAUQ Laboratorista: WELINGTON SOUZA Data Ensaio: 23/03/23
Pista: ANHANGUERA FAIXA 9 / 16mm Resp.pela Coleta: WELINGTON SOUZA Eng.Resp.: LEONARDO BERTELLI
CONTRATO: TIPO DE SERVIÇO:

PESO DA EXTRAÇÃO DE BETUME DA AMOSTRA


PENEIRA 1,597.30 g FAIXA DE TRABALHO
AMOSTRA DESCRIÇĀO SOXLET MUFA

E TO
Peso com Betume 1,300.16 1,673.18

OJ
PR
ASTM mm Peso acum. % retida % Passan. Min Max
Peso sem Betume 1,241.50 1,597.30
1" 25 0.00 0.0% 100% 100.0% 100% 100%
3/4" 19 0.00 0.0% 100.0% 99.8% 93% 100% Peso Betume 58.66 75.88
5/8" 16 70.20 4.4% 95.6% 95.5% 89% 100% % de Betume 4.51% 4.54%
1/2" 12.7 293.2 18.4% 81.6% 81.7% 75% 89% FATOR DE CORREÇĀO ROTAREX
3/8" 9.5 419.5 26.3% 73.7% 68.4% 61% 75% Teor de betume adotado 4.54%
Nº 4 4.8 837.7 52.4% 47.6% 45.9% 41% 51%
Nº 10 2 1,143.8 71.6% 28.4% 28.6% 24% 34% ENSAIO DE MASSA ESPECIFICA MÁXIMA RICE)
Nº 40 0.59 1,394.2 87.3% 12.7% 12.1% 7% 17% Peso da amostra 1,932.9
Nº 80 0.18 1,445.4 90.5% 9.5% 9.1% 6% 12% Peso do frasco+agua 25oC 7,073.3
Nº 200 0.075 1,487.6 93.1% 6.9% 6.5% 5% 9% Peso frasco+agua+amostra 25oC 9,006.2
Frasco+agua+amostra vácuo 25oC 8,277.7
Volume (cm3) 728.5
M.E. Teor. (Rice) 728.500
9

2
1
100%
M.E.Ef. Mistura seca -21.775

EXTRAÇÃO CONFORME
80%

DADOS DO PROJETO
Teor de projeto 4.5%
60%
Dens. Real do CAP 1.003
M.E.SOLTA (RICE) 2.651
40% M.E.Ef. Mistura seca 2.874

20%

0%
0.07 0.7 7

MIX PROJETO FAIXA DE TRABALHO


FAIXA DE TRABALHO

Constante do anel 2.060 ESTABILIDADE MARSHALL RESISTENCIA À TRAÇÃO


K fluencia 0.254 CP 1 2 3 4 5 6 7
Altura 5.82 5.85 5.83
Diametro 10.12 10.13 10.11
Peso ao Ar (g) 1,149.18 1,143.24 1,168.74 Fator 1.16 1.15 1.16
Peso ao Ar (Saturado, Sup. Seca)(g) 1,150.16 1,144.73 1,171.63 Leitura 596 605 598
Peso na Água (4 minutos imerso) (g) 698.31 695.76 711.87 R. T. 1.54 1.54 1.54
Vol. Do Corpo de Prova 451.85 448.97 459.76 0.00 LIMITES
Média PROJETO
Fator de correção 1.25 1.26 1.21 0.00 MÍNIMO MÁXIMO
Densidade Aparente 2.543 2.546 2.542 2.544 2.546
Densidade Teórica 728.500 728.500 728.500 0.000 728.500 2.651
% VAZIOS (MÉTODO SUPERPAVE) 99.65% 99.65% 99.65% 99.7% 4.0% 3.0% 5.0%
% V. C. B. (MÉTODO SUPERPAVE) 11.5% 11.5% 11.5% 11.5% 11.4%
% V. A M. (MÉTODO SUPERPAVE) 15.5% 15.4% 15.6% 15.5% 15.0% > 13,0%
% R. B. V. -542.1% -546.3% -540.4% -542.9% 74.6% 65.0% 80.0%
Leitura do Deflectômetro 596 605 598 600
Estabilidade Encontrada (kg) 1,228 1,246 1,232 1,235
Estabilidade Corrigida (kg) 1,534 1,558 1,540 1,544 1,545 > 700
Fluência, Leitura (mm) 10.02 10.13 10.07 10.07 10.0 8 16
OBSERVAÇÕES:

CONCLUSÃO DO ENSAIO:
PROBLEMAS NA M.E./ENSAIO RICE- REFAZER ENSAIO COM MESMA AMOSTRA.
RELAÇÃO ESTAB. / FLUENCIA(MIN = 230 mm) = 153mm = > REVER PROJETO - MASSA INSTÁVEL
ENSAIO EXTRAÇÃO, GRANULOMETRIA E MARSHALL

Rodovia: SP- 330 Coleta: USINA - 02 Trecho: EMPREITEIRA KAPA Nº: 21 MANHÃ
Km Inicial: USINA: VAL ROCHA ENG.Projeto Mistura: 30/45 Data Coleta: 24/03/23
Km Final: Amostra: CAUQ Laboratorista: WELINGTON SOUZA Data Ensaio: 24/03/23
Pista: ANHANGUERA FAIXA 9 / 16mm Resp.pela Coleta: WELINGTON SOUZA Eng.Resp.: LEONARDO BERTELLI
CONTRATO: TIPO DE SERVIÇO:

PESO DA EXTRAÇÃO DE BETUME DA AMOSTRA


PENEIRA 1,734.00 g FAIXA DE TRABALHO
AMOSTRA DESCRIÇĀO SOXLET MUFA

E TO
Peso com Betume 1,250.63 1,817.98

OJ
PR
ASTM mm Peso acum. % retida % Passan. Min Max
Peso sem Betume 1,193.00 1,734.00
1" 25 0.00 0.0% 100% 100.0% 100% 100%
3/4" 19 0.00 0.0% 100.0% 99.8% 93% 100% Peso Betume 57.63 83.98
5/8" 16 95.60 5.5% 94.5% 95.5% 89% 100% % de Betume 4.61% 4.62%
1/2" 12.7 314.8 18.2% 81.8% 81.7% 75% 89% FATOR DE CORREÇĀO ROTAREX
3/8" 9.5 487.3 28.1% 71.9% 68.4% 61% 75% Teor de betume adotado 4.62%
Nº 4 4.8 874.6 50.4% 49.6% 45.9% 41% 51%
Nº 10 2 1,252.7 72.2% 27.8% 28.6% 24% 34% ENSAIO DE MASSA ESPECIFICA MÁXIMA RICE)
Nº 40 0.59 1,523.3 87.8% 12.2% 12.1% 7% 17% Peso da amostra 1,948.1
Nº 80 0.18 1,577.7 91.0% 9.0% 9.1% 6% 12% Peso do frasco+agua 25oC 7,074.5
Nº 200 0.075 1,610.6 92.9% 7.1% 6.5% 5% 9% Peso frasco+agua+amostra 25oC 9,022.6
Frasco+agua+amostra vácuo 25oC 8,287.2
Volume (cm3) 735.4
M.E. Teor. (Rice) 735.400
9

2
1
100%
M.E.Ef. Mistura seca -21.340

EXTRAÇÃO CONFORME
80%

DADOS DO PROJETO
Teor de projeto 4.5%
60%
Dens. Real do CAP 1.003
M.E.SOLTA (RICE) 2.651
40% M.E.Ef. Mistura seca 2.874

20%

0%
0.07 0.7 7

MIX PROJETO FAIXA DE TRABALHO


FAIXA DE TRABALHO

Constante do anel 2.060 ESTABILIDADE MARSHALL RESISTENCIA À TRAÇÃO


K fluencia 0.254 CP 1 2 3 4 5 6 7
Altura 5.86 5.87 5.85
Diametro 10.14 10.11 10.10
Peso ao Ar (g) 1,152.99 1,146.53 1,152.81 Fator 1.15 1.14 1.15
Peso ao Ar (Saturado, Sup. Seca)(g) 1,154.13 1,147.95 1,153.00 Leitura 608 610 605
Peso na Água (4 minutos imerso) (g) 701.29 696.13 699.83 R. T. 1.54 1.54 1.55
Vol. Do Corpo de Prova 452.84 451.82 453.17 0.00 LIMITES
Média PROJETO
Fator de correção 1.25 1.25 1.24 0.00 MÍNIMO MÁXIMO
Densidade Aparente 2.546 2.538 2.544 2.543 2.546
Densidade Teórica 735.400 735.400 735.400 0.000 735.400 2.651
% VAZIOS (MÉTODO SUPERPAVE) 99.65% 99.65% 99.65% 99.7% 4.0% 3.0% 5.0%
% V. C. B. (MÉTODO SUPERPAVE) 11.7% 11.7% 11.7% 11.7% 11.4%
% V. A M. (MÉTODO SUPERPAVE) 15.5% 15.8% 15.6% 15.6% 15.0% > 13,0%
% R. B. V. -542.9% -531.4% -539.8% -538.0% 74.6% 65.0% 80.0%
Leitura do Deflectômetro 608 610 605 608
Estabilidade Encontrada (kg) 1,252 1,257 1,246 1,252
Estabilidade Corrigida (kg) 1,559 1,565 1,552 1,559 1,545 > 700
Fluência, Leitura (mm) 10.22 9.89 10.12 10.08 10.0 8 16
OBSERVAÇÕES:

CONCLUSÃO DO ENSAIO:
PROBLEMAS NA M.E./ENSAIO RICE- REFAZER ENSAIO COM MESMA AMOSTRA.
RELAÇÃO ESTAB. / FLUENCIA(MIN = 230 mm) = 155mm = > REVER PROJETO - MASSA INSTÁVEL
ENSAIO EXTRAÇÃO, GRANULOMETRIA E MARSHALL

Rodovia: SP- 330 Coleta: USINA - 02 Trecho: EMPREITEIRA KAPA Nº: 22 MANHÃ
Km Inicial: USINA: VAL ROCHA ENG.Projeto Mistura: 30/45 Data Coleta: 25/03/23
Km Final: Amostra: CAUQ Laboratorista: WELINGTON SOUZA Data Ensaio: 25/03/23
Pista: ANHANGUERA FAIXA 9 / 16mm Resp.pela Coleta: WELINGTON SOUZA Eng.Resp.: LEONARDO BERTELLI
CONTRATO: TIPO DE SERVIÇO:

PESO DA EXTRAÇÃO DE BETUME DA AMOSTRA


PENEIRA 1,502.90 g FAIXA DE TRABALHO
AMOSTRA DESCRIÇĀO SOXLET MUFA

E TO
Peso com Betume 1,437.69 1,574.70

OJ
PR
ASTM mm Peso acum. % retida % Passan. Min Max
Peso sem Betume 1,373.00 1,502.90
1" 25 0.00 0.0% 100% 100.0% 100% 100%
3/4" 19 0.00 0.0% 100.0% 99.8% 93% 100% Peso Betume 64.69 71.80
5/8" 16 106.30 7.1% 92.9% 95.5% 89% 100% % de Betume 4.50% 4.56%
1/2" 12.7 337.4 22.4% 77.6% 81.7% 75% 89% FATOR DE CORREÇĀO ROTAREX
3/8" 9.5 494.5 32.9% 67.1% 68.4% 61% 75% Teor de betume adotado 4.56%
Nº 4 4.8 819.4 54.5% 45.5% 45.9% 41% 51%
Nº 10 2 1,126.1 74.9% 25.1% 28.6% 24% 34% ENSAIO DE MASSA ESPECIFICA MÁXIMA RICE)
Nº 40 0.59 1,329.7 88.5% 11.5% 12.1% 7% 17% Peso da amostra 1,991.8
Nº 80 0.18 1,370.2 91.2% 8.8% 9.1% 6% 12% Peso do frasco+agua 25oC 7,074.5
Nº 200 0.075 1,398.0 93.0% 7.0% 6.5% 5% 9% Peso frasco+agua+amostra 25oC 9,066.3
Frasco+agua+amostra vácuo 25oC 8,316.0
Volume (cm3) 750.3
M.E. Teor. (Rice) 750.320
9

2
1
100%
M.E.Ef. Mistura seca -21.629

EXTRAÇÃO CONFORME
80%

DADOS DO PROJETO
Teor de projeto 4.5%
60%
Dens. Real do CAP 1.003
M.E.SOLTA (RICE) 2.651
40% M.E.Ef. Mistura seca 2.874

20%

0%
0.07 0.7 7

MIX PROJETO FAIXA DE TRABALHO


FAIXA DE TRABALHO

Constante do anel 2.060 ESTABILIDADE MARSHALL RESISTENCIA À TRAÇÃO


K fluencia 0.254 CP 1 2 3 4 5 6 7
Altura 5.87 5.85 5.88
Diametro 10.12 10.14 10.13
Peso ao Ar (g) 1,149.88 1,155.44 1,151.61 Fator 1.14 1.15 1.14
Peso ao Ar (Saturado, Sup. Seca)(g) 1,150.82 1,156.54 1,152.73 Leitura 611 610 615
Peso na Água (4 minutos imerso) (g) 697.49 702.55 699.80 R. T. 1.54 1.55 1.54
Vol. Do Corpo de Prova 453.33 453.99 452.93 0.00 LIMITES
Média PROJETO
Fator de correção 1.24 1.24 1.24 0.00 MÍNIMO MÁXIMO
Densidade Aparente 2.537 2.545 2.543 2.541 2.546
Densidade Teórica 750.320 750.320 750.320 0.000 750.320 2.651
% VAZIOS (MÉTODO SUPERPAVE) 99.66% 99.66% 99.66% 99.7% 4.0% 3.0% 5.0%
% V. C. B. (MÉTODO SUPERPAVE) 11.5% 11.6% 11.6% 11.6% 11.4%
% V. A M. (MÉTODO SUPERPAVE) 15.8% 15.5% 15.6% 15.6% 15.0% > 13,0%
% R. B. V. -532.1% -543.7% -540.3% -538.7% 74.6% 65.0% 80.0%
Leitura do Deflectômetro 611 610 615 612
Estabilidade Encontrada (kg) 1,259 1,257 1,267 1,261
Estabilidade Corrigida (kg) 1,564 1,562 1,574 1,567 1,545 > 700
Fluência, Leitura (mm) 10.20 9.99 10.08 10.09 10.0 8 16
OBSERVAÇÕES:

CONCLUSÃO DO ENSAIO:
PROBLEMAS NA M.E./ENSAIO RICE- REFAZER ENSAIO COM MESMA AMOSTRA.
RELAÇÃO ESTAB. / FLUENCIA(MIN = 230 mm) = 155mm = > REVER PROJETO - MASSA INSTÁVEL
ENSAIO EXTRAÇÃO, GRANULOMETRIA E MARSHALL

Rodovia: SP- 330 Coleta: USINA - 02 Trecho: EMPREITEIRA KAPA Nº: 23 MANHÃ
Km Inicial: USINA: VAL ROCHA ENG.Projeto Mistura: 30/45 Data Coleta: 27/03/23
Km Final: Amostra: CAUQ Laboratorista: WELINGTON SOUZA Data Ensaio: 27/03/23
Pista: ANHANGUERA FAIXA 9 / 16mm Resp.pela Coleta: WELINGTON SOUZA Eng.Resp.: LEONARDO BERTELLI
CONTRATO: TIPO DE SERVIÇO:

PESO DA EXTRAÇÃO DE BETUME DA AMOSTRA


PENEIRA 1,383.60 g FAIXA DE TRABALHO
AMOSTRA DESCRIÇĀO SOXLET MUFA

E TO
Peso com Betume 1,341.92 1,449.79

OJ
PR
ASTM mm Peso acum. % retida % Passan. Min Max
Peso sem Betume 1,282.60 1,383.60
1" 25 0.00 0.0% 100% 100.0% 100% 100%
3/4" 19 8.40 0.6% 99.4% 99.8% 93% 100% Peso Betume 59.32 66.19
5/8" 16 21.20 1.5% 98.5% 95.5% 89% 100% % de Betume 4.42% 4.57%
1/2" 12.7 205.2 14.8% 85.2% 81.7% 75% 89% FATOR DE CORREÇĀO ROTAREX
3/8" 9.5 368.7 26.6% 73.4% 68.4% 61% 75% Teor de betume adotado 4.57%
Nº 4 4.8 691.7 50.0% 50.0% 45.9% 41% 51%
Nº 10 2 991.2 71.6% 28.4% 28.6% 24% 34% ENSAIO DE MASSA ESPECIFICA MÁXIMA RICE)
Nº 40 0.59 1,208.7 87.4% 12.6% 12.1% 7% 17% Peso da amostra 1,991.9
Nº 80 0.18 1,255.3 90.7% 9.3% 9.1% 6% 12% Peso do frasco+agua 25oC 7,074.3
Nº 200 0.075 1,292.6 93.4% 6.6% 6.5% 5% 9% Peso frasco+agua+amostra 25oC 9,066.2
Frasco+agua+amostra vácuo 25oC 8,315.8
Volume (cm3) 750.4
M.E. Teor. (Rice) 750.400
9

2
1
100%
M.E.Ef. Mistura seca -21.599

EXTRAÇÃO CONFORME
80%

DADOS DO PROJETO
Teor de projeto 4.5%
60%
Dens. Real do CAP 1.003
M.E.SOLTA (RICE) 2.651
40% M.E.Ef. Mistura seca 2.874

20%

0%
0.07 0.7 7

MIX PROJETO FAIXA DE TRABALHO


FAIXA DE TRABALHO

Constante do anel 2.060 ESTABILIDADE MARSHALL RESISTENCIA À TRAÇÃO


K fluencia 0.254 CP 1 2 3 4 5 6 7
Altura 5.85 5.88 5.87
Diametro 10.14 10.11 10.15
Peso ao Ar (g) 1,148.23 1,154.38 1,150.53 Fator 1.15 1.14 1.14
Peso ao Ar (Saturado, Sup. Seca)(g) 1,150.34 1,156.46 1,152.63 Leitura 608 612 613
Peso na Água (4 minutos imerso) (g) 698.98 702.79 699.85 R. T. 1.55 1.54 1.54
Vol. Do Corpo de Prova 451.36 453.67 452.78 0.00 LIMITES
Média PROJETO
Fator de correção 1.25 1.24 1.25 0.00 MÍNIMO MÁXIMO
Densidade Aparente 2.544 2.545 2.541 2.543 2.546
Densidade Teórica 750.400 750.400 750.400 0.000 750.400 2.651
% VAZIOS (MÉTODO SUPERPAVE) 99.66% 99.66% 99.66% 99.7% 4.0% 3.0% 5.0%
% V. C. B. (MÉTODO SUPERPAVE) 11.6% 11.6% 11.6% 11.6% 11.4%
% V. A M. (MÉTODO SUPERPAVE) 15.5% 15.5% 15.6% 15.6% 15.0% > 13,0%
% R. B. V. -541.9% -542.7% -538.0% -540.9% 74.6% 65.0% 80.0%
Leitura do Deflectômetro 608 612 613 611
Estabilidade Encontrada (kg) 1,252 1,261 1,263 1,259
Estabilidade Corrigida (kg) 1,568 1,578 1,581 1,576 1,545 > 700
Fluência, Leitura (mm) 10.18 10.06 10.01 10.08 10.0 8 16
OBSERVAÇÕES:

CONCLUSÃO DO ENSAIO:
PROBLEMAS NA M.E./ENSAIO RICE- REFAZER ENSAIO COM MESMA AMOSTRA.
RELAÇÃO ESTAB. / FLUENCIA(MIN = 230 mm) = 156mm = > REVER PROJETO - MASSA INSTÁVEL
ENSAIO EXTRAÇÃO, GRANULOMETRIA E MARSHALL

Rodovia: SP- 330 Coleta: USINA - 02 Trecho: EMPREITEIRA KAPA Nº: 24 MANHÃ
Km Inicial: USINA: VAL ROCHA ENG.Projeto Mistura: 30/45 Data Coleta: 28/03/23
Km Final: Amostra: CAUQ Laboratorista: WELINGTON SOUZA Data Ensaio: 28/03/23
Pista: ANHANGUERA FAIXA 9 / 16mm Resp.pela Coleta: WELINGTON SOUZA Eng.Resp.: LEONARDO BERTELLI
CONTRATO: TIPO DE SERVIÇO:

PESO DA EXTRAÇÃO DE BETUME DA AMOSTRA


PENEIRA 1,741.99 g FAIXA DE TRABALHO
AMOSTRA DESCRIÇĀO SOXLET MUFA

E TO
Peso com Betume 1,112.95 1,825.77

OJ
PR
ASTM mm Peso acum. % retida % Passan. Min Max
Peso sem Betume 1,062.30 1,741.99
1" 25 0.00 0.0% 100% 100.0% 100% 100%
3/4" 19 0.00 0.0% 100.0% 99.8% 93% 100% Peso Betume 50.65 83.78
5/8" 16 50.80 2.9% 97.1% 95.5% 89% 100% % de Betume 4.55% 4.59%
1/2" 12.7 313.2 18.0% 82.0% 81.7% 75% 89% FATOR DE CORREÇĀO ROTAREX
3/8" 9.5 540.7 31.0% 69.0% 68.4% 61% 75% Teor de betume adotado 4.59%
Nº 4 4.8 972.2 55.8% 44.2% 45.9% 41% 51%
Nº 10 2 1,307.8 75.1% 24.9% 28.6% 24% 34% ENSAIO DE MASSA ESPECIFICA MÁXIMA RICE)
Nº 40 0.59 1,600.5 91.9% 8.1% 12.1% 7% 17% Peso da amostra 2,048.4
Nº 80 0.18 1,622.3 93.1% 6.9% 9.1% 6% 12% Peso do frasco+agua 25oC 7,070.8
Nº 200 0.075 1,624.0 93.2% 6.8% 6.5% 5% 9% Peso frasco+agua+amostra 25oC 9,119.2
Frasco+agua+amostra vácuo 25oC 8,345.6
Volume (cm3) 773.6
M.E. Teor. (Rice) 773.600
9

2
1
100%
M.E.Ef. Mistura seca -21.461

EXTRAÇÃO CONFORME
80%

DADOS DO PROJETO
Teor de projeto 4.5%
60%
Dens. Real do CAP 1.003
M.E.SOLTA (RICE) 2.651
40% M.E.Ef. Mistura seca 2.874

20%

0%
0.07 0.7 7

MIX PROJETO FAIXA DE TRABALHO


FAIXA DE TRABALHO

Constante do anel 2.060 ESTABILIDADE MARSHALL RESISTENCIA À TRAÇÃO


K fluencia 0.254 CP 1 2 3 4 5 6 7
Altura 5.85 5.83 5.86
Diametro 10.11 10.14 10.12
Peso ao Ar (g) 1,147.19 1,153.47 1,149.61 Fator 1.15 1.16 1.15
Peso ao Ar (Saturado, Sup. Seca)(g) 1,149.28 1,155.52 1,151.74 Leitura 605 600 608
Peso na Água (4 minutos imerso) (g) 697.82 701.66 699.93 R. T. 1.54 1.54 1.55
Vol. Do Corpo de Prova 451.46 453.86 451.81 0.00 LIMITES
Média PROJETO
Fator de correção 1.25 1.24 1.25 0.00 MÍNIMO MÁXIMO
Densidade Aparente 2.541 2.541 2.544 2.542 2.546
Densidade Teórica 773.600 773.600 773.600 0.000 773.600 2.651
% VAZIOS (MÉTODO SUPERPAVE) 99.67% 99.67% 99.67% 99.7% 4.0% 3.0% 5.0%
% V. C. B. (MÉTODO SUPERPAVE) 11.6% 11.6% 11.6% 11.6% 11.4%
% V. A M. (MÉTODO SUPERPAVE) 15.6% 15.6% 15.5% 15.6% 15.0% > 13,0%
% R. B. V. -537.2% -537.8% -541.8% -538.9% 74.6% 65.0% 80.0%
Leitura do Deflectômetro 605 600 608 604
Estabilidade Encontrada (kg) 1,246 1,236 1,252 1,245
Estabilidade Corrigida (kg) 1,560 1,547 1,568 1,558 1,545 > 700
Fluência, Leitura (mm) 10.13 9.97 9.98 10.03 10.0 8 16
OBSERVAÇÕES:

CONCLUSÃO DO ENSAIO:
PROBLEMAS NA M.E./ENSAIO RICE- REFAZER ENSAIO COM MESMA AMOSTRA.
RELAÇÃO ESTAB. / FLUENCIA(MIN = 230 mm) = 155mm = > REVER PROJETO - MASSA INSTÁVEL
ENSAIO EXTRAÇÃO, GRANULOMETRIA E MARSHALL

Rodovia: SP- 330 Coleta: USINA - 02 Trecho: EMPREITEIRA KAPA Nº: 25 MANHÃ
Km Inicial: USINA: VAL ROCHA ENG.Projeto Mistura: 30/45 Data Coleta: 29/03/23
Km Final: Amostra: CAUQ Laboratorista: WELINGTON SOUZA Data Ensaio: 29/03/23
Pista: ANHANGUERA FAIXA 9 / 16mm Resp.pela Coleta: WELINGTON SOUZA Eng.Resp.: LEONARDO BERTELLI
CONTRATO: TIPO DE SERVIÇO:

PESO DA EXTRAÇÃO DE BETUME DA AMOSTRA


PENEIRA 1,755.80 g FAIXA DE TRABALHO
AMOSTRA DESCRIÇĀO SOXLET MUFA

E TO
Peso com Betume 1,495.60 1,837.84

OJ
PR
ASTM mm Peso acum. % retida % Passan. Min Max
Peso sem Betume 1,429.30 1,755.80
1" 25 0.00 0.0% 100% 100.0% 100% 100%
3/4" 19 18.70 1.1% 98.9% 99.8% 93% 100% Peso Betume 66.30 82.04
5/8" 16 142.00 8.1% 91.9% 95.5% 89% 100% % de Betume 4.43% 4.46%
1/2" 12.7 313.2 17.8% 82.2% 81.7% 75% 89% FATOR DE CORREÇĀO ROTAREX
3/8" 9.5 540.7 30.8% 69.2% 68.4% 61% 75% Teor de betume adotado 4.46%
Nº 4 4.8 972.2 55.4% 44.6% 45.9% 41% 51%
Nº 10 2 1,307.8 74.5% 25.5% 28.6% 24% 34% ENSAIO DE MASSA ESPECIFICA MÁXIMA RICE)
Nº 40 0.59 1,600.5 91.2% 8.8% 12.1% 7% 17% Peso da amostra 1,867.6
Nº 80 0.18 1,622.3 92.4% 7.6% 9.1% 6% 12% Peso do frasco+agua 25oC 7,067.5
Nº 200 0.075 1,624.0 92.5% 7.5% 6.5% 5% 9% Peso frasco+agua+amostra 25oC 8,935.1
Frasco+agua+amostra vácuo 25oC 8,230.1
Volume (cm3) 705.0
M.E. Teor. (Rice) 705.000
9

2
1
100%
M.E.Ef. Mistura seca -22.173

EXTRAÇÃO CONFORME
80%

DADOS DO PROJETO
Teor de projeto 4.5%
60%
Dens. Real do CAP 1.003
M.E.SOLTA (RICE) 2.651
40% M.E.Ef. Mistura seca 2.874

20%

0%
0.07 0.7 7

MIX PROJETO FAIXA DE TRABALHO


FAIXA DE TRABALHO

Constante do anel 2.060 ESTABILIDADE MARSHALL RESISTENCIA À TRAÇÃO


K fluencia 0.254 CP 1 2 3 4 5 6 7
Altura 5.88 5.91 5.90
Diametro 10.14 10.13 10.10
Peso ao Ar (g) 1,174.40 1,182.92 1,151.89 Fator 1.14 1.13 1.13
Peso ao Ar (Saturado, Sup. Seca)(g) 1,176.12 1,184.40 1,153.11 Leitura 615 618 620
Peso na Água (4 minutos imerso) (g) 716.26 718.80 698.86 R. T. 1.54 1.53 1.54
Vol. Do Corpo de Prova 459.86 465.60 454.25 0.00 LIMITES
Média PROJETO
Fator de correção 1.21 1.19 1.24 0.00 MÍNIMO MÁXIMO
Densidade Aparente 2.554 2.541 2.536 2.543 2.546
Densidade Teórica 705.000 705.000 705.000 0.000 705.000 2.651
% VAZIOS (MÉTODO SUPERPAVE) 99.64% 99.64% 99.64% 99.6% 4.0% 3.0% 5.0%
% V. C. B. (MÉTODO SUPERPAVE) 11.4% 11.3% 11.3% 11.3% 11.4%
% V. A M. (MÉTODO SUPERPAVE) 15.1% 15.5% 15.7% 15.5% 15.0% > 13,0%
% R. B. V. -559.5% -541.0% -534.4% -545.0% 74.6% 65.0% 80.0%
Leitura do Deflectômetro 615 618 620 618
Estabilidade Encontrada (kg) 1,267 1,273 1,277 1,272
Estabilidade Corrigida (kg) 1,536 1,544 1,549 1,543 1,545 > 700
Fluência, Leitura (mm) 10.11 9.99 9.95 10.02 10.0 8 16
OBSERVAÇÕES:

CONCLUSÃO DO ENSAIO:
PROBLEMAS NA M.E./ENSAIO RICE- REFAZER ENSAIO COM MESMA AMOSTRA.
RELAÇÃO ESTAB. / FLUENCIA(MIN = 230 mm) = 154mm = > REVER PROJETO - MASSA INSTÁVEL
ENSAIO EXTRAÇÃO, GRANULOMETRIA E MARSHALL

Rodovia: SP- 330 Coleta: USINA - 02 Trecho: EMPREITEIRA KAPA Nº: 26 MANHÃ
Km Inicial: USINA: VAL ROCHA ENG.Projeto Mistura: 30/45 Data Coleta: 30/03/23
Km Final: Amostra: CAUQ Laboratorista: WELINGTON SOUZA Data Ensaio: 30/03/23
Pista: ANHANGUERA FAIXA 9 / 16mm Resp.pela Coleta: WELINGTON SOUZA Eng.Resp.: LEONARDO BERTELLI
CONTRATO: TIPO DE SERVIÇO:

PESO DA EXTRAÇÃO DE BETUME DA AMOSTRA


PENEIRA 1,581.10 g FAIXA DE TRABALHO
AMOSTRA DESCRIÇĀO SOXLET MUFA

E TO
Peso com Betume 1,492.80 1,657.65

OJ
PR
ASTM mm Peso acum. % retida % Passan. Min Max
Peso sem Betume 1,425.35 1,581.10
1" 25 0.00 0.0% 100% 100.0% 100% 100%
3/4" 19 0.00 0.0% 100.0% 99.8% 93% 100% Peso Betume 67.45 76.55
5/8" 16 54.10 3.4% 96.6% 95.5% 89% 100% % de Betume 4.52% 4.62%
1/2" 12.7 244.9 15.5% 84.5% 81.7% 75% 89% FATOR DE CORREÇĀO ROTAREX
3/8" 9.5 497.5 31.5% 68.5% 68.4% 61% 75% Teor de betume adotado 4.62%
Nº 4 4.8 873.8 55.3% 44.7% 45.9% 41% 51%
Nº 10 2 1,144.2 72.4% 27.6% 28.6% 24% 34% ENSAIO DE MASSA ESPECIFICA MÁXIMA RICE)
Nº 40 0.59 1,386.0 87.7% 12.3% 12.1% 7% 17% Peso da amostra 1,961.8
Nº 80 0.18 1,432.8 90.6% 9.4% 9.1% 6% 12% Peso do frasco+agua 25oC 7,066.6
Nº 200 0.075 1,465.4 92.7% 7.3% 6.5% 5% 9% Peso frasco+agua+amostra 25oC 9,028.4
Frasco+agua+amostra vácuo 25oC 8,288.4
Volume (cm3) 740.0
M.E. Teor. (Rice) 740.000
9

2
1
100%
M.E.Ef. Mistura seca -21.343

EXTRAÇÃO CONFORME
80%

DADOS DO PROJETO
Teor de projeto 4.5%
60%
Dens. Real do CAP 1.003
M.E.SOLTA (RICE) 2.651
40% M.E.Ef. Mistura seca 2.874

20%

0%
0.07 0.7 7

MIX PROJETO FAIXA DE TRABALHO


FAIXA DE TRABALHO

Constante do anel 2.060 ESTABILIDADE MARSHALL RESISTENCIA À TRAÇÃO


K fluencia 0.254 CP 1 2 3 4 5 6 7
Altura 5.86 5.85 5.83
Diametro 10.13 10.10 10.12
Peso ao Ar (g) 1,196.16 1,194.08 1,145.22 Fator 1.15 1.15 1.16
Peso ao Ar (Saturado, Sup. Seca)(g) 1,198.12 1,196.28 1,147.12 Leitura 610 609 599
Peso na Água (4 minutos imerso) (g) 727.58 726.28 699.16 R. T. 1.55 1.56 1.55
Vol. Do Corpo de Prova 470.54 470.00 447.96 0.00 LIMITES
Média PROJETO
Fator de correção 1.17 1.17 1.27 0.00 MÍNIMO MÁXIMO
Densidade Aparente 2.542 2.541 2.557 2.546 2.546
Densidade Teórica 740.000 740.000 740.000 0.000 740.000 2.651
% VAZIOS (MÉTODO SUPERPAVE) 99.66% 99.66% 99.65% 99.7% 4.0% 3.0% 5.0%
% V. C. B. (MÉTODO SUPERPAVE) 11.7% 11.7% 11.8% 11.7% 11.4%
% V. A M. (MÉTODO SUPERPAVE) 15.6% 15.7% 15.2% 15.5% 15.0% > 13,0%
% R. B. V. -537.5% -535.4% -557.6% -543.5% 74.6% 65.0% 80.0%
Leitura do Deflectômetro 610 609 599 606
Estabilidade Encontrada (kg) 1,257 1,255 1,234 1,248
Estabilidade Corrigida (kg) 1,465 1,462 1,438 1,455 1,545 > 700
Fluência, Leitura (mm) 9.96 9.99 9.99 9.98 10.0 8 16
OBSERVAÇÕES:

CONCLUSÃO DO ENSAIO:
PROBLEMAS NA M.E./ENSAIO RICE- REFAZER ENSAIO COM MESMA AMOSTRA.
RELAÇÃO ESTAB. / FLUENCIA(MIN = 230 mm) = 146mm = > REVER PROJETO - MASSA INSTÁVEL
ENSAIO EXTRAÇÃO, GRANULOMETRIA E MARSHALL

Rodovia: SP- 330 Coleta: USINA - 02 Trecho: EMPREITEIRA KAPA Nº: 27 MANHÃ
Km Inicial: USINA: VAL ROCHA ENG.Projeto Mistura: 30/45 Data Coleta: 31/03/23
Km Final: Amostra: CAUQ Laboratorista: WELINGTON SOUZA Data Ensaio: 31/03/23
Pista: ANHANGUERA FAIXA 9 / 16mm Resp.pela Coleta: WELINGTON SOUZA Eng.Resp.: LEONARDO BERTELLI
CONTRATO: TIPO DE SERVIÇO:

PESO DA EXTRAÇÃO DE BETUME DA AMOSTRA


PENEIRA 1,357.00 g FAIXA DE TRABALHO
AMOSTRA DESCRIÇĀO SOXLET MUFA

E TO
Peso com Betume 1,181.15 1,422.15

OJ
PR
ASTM mm Peso acum. % retida % Passan. Min Max
Peso sem Betume 1,126.30 1,357.00
1" 25 0.00 0.0% 100% 100.0% 100% 100%
3/4" 19 19.30 1.4% 98.6% 99.8% 93% 100% Peso Betume 54.85 65.15
5/8" 16 83.10 6.1% 93.9% 95.5% 89% 100% % de Betume 4.64% 4.58%
1/2" 12.7 245.1 18.1% 81.9% 81.7% 75% 89% FATOR DE CORREÇĀO ROTAREX
3/8" 9.5 366.7 27.0% 73.0% 68.4% 61% 75% Teor de betume adotado 4.58%
Nº 4 4.8 675.5 49.8% 50.2% 45.9% 41% 51%
Nº 10 2 1,004.1 74.0% 26.0% 28.6% 24% 34% ENSAIO DE MASSA ESPECIFICA MÁXIMA RICE)
Nº 40 0.59 1,188.4 87.6% 12.4% 12.1% 7% 17% Peso da amostra 1,842.5
Nº 80 0.18 1,225.4 90.3% 9.7% 9.1% 6% 12% Peso do frasco+agua 25oC 7,067.4
Nº 200 0.075 1,271.5 93.7% 6.3% 6.5% 5% 9% Peso frasco+agua+amostra 25oC 8,909.9
Frasco+agua+amostra vácuo 25oC 8,213.4
Volume (cm3) 696.5
M.E. Teor. (Rice) 696.500
9

2
1
100%
M.E.Ef. Mistura seca -21.569

EXTRAÇÃO CONFORME
80%

DADOS DO PROJETO
Teor de projeto 4.5%
60%
Dens. Real do CAP 1.003
M.E.SOLTA (RICE) 2.651
40% M.E.Ef. Mistura seca 2.874

20%

0%
0.07 0.7 7

MIX PROJETO FAIXA DE TRABALHO


FAIXA DE TRABALHO

Constante do anel 2.060 ESTABILIDADE MARSHALL RESISTENCIA À TRAÇÃO


K fluencia 0.254 CP 1 2 3 4 5 6 7
Altura 5.89 5.89 5.83
Diametro 10.11 10.12 10.14
Peso ao Ar (g) 1,146.34 1,144.08 1,145.21 Fator 1.14 1.14 1.16
Peso ao Ar (Saturado, Sup. Seca)(g) 1,147.58 1,145.76 1,146.67 Leitura 612 615 602
Peso na Água (4 minutos imerso) (g) 699.37 697.00 698.18 R. T. 1.54 1.54 1.55
Vol. Do Corpo de Prova 448.21 448.76 448.49 0.00 LIMITES
Média PROJETO
Fator de correção 1.27 1.26 1.27 0.00 MÍNIMO MÁXIMO
Densidade Aparente 2.558 2.549 2.553 2.554 2.546
Densidade Teórica 696.500 696.500 696.500 0.000 696.500 2.651
% VAZIOS (MÉTODO SUPERPAVE) 99.63% 99.63% 99.63% 99.6% 4.0% 3.0% 5.0%
% V. C. B. (MÉTODO SUPERPAVE) 11.7% 11.6% 11.7% 11.7% 11.4%
% V. A M. (MÉTODO SUPERPAVE) 15.1% 15.4% 15.2% 15.2% 15.0% > 13,0%
% R. B. V. -560.4% -548.8% -554.5% -554.6% 74.6% 65.0% 80.0%
Leitura do Deflectômetro 612 615 602 610
Estabilidade Encontrada (kg) 1,261 1,267 1,240 1,256
Estabilidade Corrigida (kg) 1,597 1,605 1,571 1,591 1,545 > 700
Fluência, Leitura (mm) 9.92 10.06 10.09 10.02 10.0 8 16
OBSERVAÇÕES:

CONCLUSÃO DO ENSAIO:
PROBLEMAS NA M.E./ENSAIO RICE- REFAZER ENSAIO COM MESMA AMOSTRA.
RELAÇÃO ESTAB. / FLUENCIA(MIN = 230 mm) = 159mm = > REVER PROJETO - MASSA INSTÁVEL