Você está na página 1de 3

ESQUEMA ELÉTRICO P/ALIMENTAÇÃO DOS CLIMATIZADORES CRONOS EM 380V

VENTILAÇÃO COMERCIAL E INDUSTRIAL ALIMENTAÇÃO DIRETA DO QG SUBESTAÇÃO


SISTEMA AUTOMATICO E MANUAL

Cliente: NAVARROMED
QDC1 DISJUNTOR 60A TRIPOLAR

DISJUNTOR 10A UNIPOLAR P/BOMBAS


DISJUNTOR 40A TRIPOLAR P/MANUAL
DISJUNTOR 40A TRIPOLAR P/AUTOMATICO
CORTE TAMPA QDC1 TAMPA QDC1 QDC1 - QUADRO COMPOSTO POR
QDC 1
IGBT -01 DISJUNTOR 60A TRIPOLAR
-01 DISJUNTOR 40A TRIPOLAR P/SISTEMA AUTOMATICO
CLIMATIZADOR 04 BOMBAS 1
0
2 -01 DISJUNTOR 40A TRIPOLAR P/SISTEMA MANUAL
-01 DISJUNTOR 10A UNIPOLAR P/BOMBAS
-01 CHAVE SELETORA P/ AUTOMATICO/MANUAL
-01 INVERSOR IGBT P/04 MOTORES 3CV (5.2A CADA)
CLIMATIZADOR 01 CLIMATIZADOR 02 CLIMATIZADOR 03 IEXAUSTOR 01 BOMBAS

TAMPA EXTERNA
-04 INTERRUPTORES P/CHAVE DE PARTIDA DIRETA
-04 LED VERMELHA P/MOTORES
-01 INTERRUPTOR P/BOMBAS

CABO PP 1,0MM -4 VIAS


CABO PP 1,0MM -4 VIAS
CABO PP 1,0MM -4 VIAS
CABO PP 1,0MM -4 VIAS
-01 LED AZUL P/BOMBAS

1F 2,5MM
-PLACAS DE IDENTIFICAÇÃO

CABO PP 1,0MM -4 VIAS


CHAVE DE PARTIDA DIRETA C/FUSIVEL DE PROTEÇÃO
01 P/CADA MOTOR

1 4MM
3F 8 MM
1N 4MM

FUSIVEL DE PROTEÇÃO FUSIVEL DE PROTEÇÃO FUSIVEL DE PROTEÇÃO FUSIVEL DE PROTEÇÃO

3,0CV 3,0CV 3,0CV 3,0CV

ELABORADO POR
Mucio Nery Fabiano / Luciene Fabiano
Resp. Tecnico Layout
ESQUEMA ELÉTRICO P/ALIMENTAÇÃO DOS CLIMATIZADORES HERCULES / EXAUSTORi138 / INSULFLADOR EM 380V

VENTILAÇÃO COMERCIAL E INDUSTRIAL ALIMENTAÇÃO DIRETA DO QG SUBESTAÇÃO


SISTEMA AUTOMATICO E MANUAL

Cliente: NAVARROMED
QDC2 DISJUNTOR 100A TRIPOLAR

DISJUNTOR 40A TRIPOLAR P/DERIVAR QDC3 -EXAUSTORES

DISJUNTOR 60A TRIPOLAR


DISJUNTOR 10A TRIPOLAR P/EXAUSTOR/INSULFLADOR DISJUNTOR 10A UNIPOLAR P/BOMBAS
DISJUNTOR 40A TRIPOLAR P/MANUAL
DISJUNTOR 40A TRIPOLAR P/AUTOMATICO
CORTE TAMPA QDC2 TAMPA QDC2 QDC2 - QUADRO COMPOSTO POR
QDC 2
IGBT -01 DISJUNTOR DE 100A TRIPOLAR
-01 DISJUNTOR 60A TRIPOLAR
CLIMATIZADOR 04 EXAUSTOR 01 BOMBAS 1
0
2 -01 DISJUNTOR DE 40A P/DERIVAR QDC3
-01 DISJUNTOR 40A TRIPOLAR P/SIST. AUTOMATICO
-01 DISJUNTOR 40A TRIPOLAR P/SIST. MANUAL
-01 DISJUNTOR 10A UNIPOLAR P/BOMBAS
CLIMATIZADOR 01 CLIMATIZADOR 02 CLIMATIZADOR 03 CLIMATIZADOR 04 BOMBAS

-01 DISJUNTOR 10A TRIPOLAR P/EXAUSTOR


-01 CHAVE SELETORA P/ AUTOMATICO/MANUAL
-01 INVERSOR IGBT P/03 MOTORES 2,0CV (3,8A CADA)

TAMPA EXTERNA

CABO PP 1,0MM -4 VIAS


CABO PP 1,0MM -4 VIAS

3F 4 MM

1F 2,5MM
CABO PP 1,0MM -4 VIAS
-04 INTERRUPTORES P/CHAVE DE PARTIDA DIRETA
-04 LED VERMELHA P/MOTORES
-01 INTERRUPTOR P/BOMBAS
-01 LED AZUL P/BOMBAS
-PLACAS DE IDENTIFICAÇÃO

CABO PP 1,0MM -4 VIAS


CHAVE DE PARTIDA DIRETA C/FUSIVEL DE PROTEÇÃO
01 P/CADA MOTOR
3F 4 MM
1 4MM
3F 8 MM
1N 4MM

FUSIVEL DE PROTEÇÃO FUSIVEL DE PROTEÇÃO FUSIVEL DE PROTEÇÃO


EXAUSTOR / INSULFLADOR

2,0CV 2,0CV 2,0CV 1,5 CV

ELABORADO POR
Mucio Nery Fabiano / Luciene Fabiano
Resp. Tecnico Layout
ESQUEMA ELÉTRICO P/ALIMENTAÇÃO DOS EXAUSTORES i138 EM 380V
ALIMENTAÇÃO DERIVADA DO QDC2
VENTILAÇÃO COMERCIAL E INDUSTRIAL

Cliente: NAVARROMED
QDC3 DISJUNTOR 40A TRIPOLAR

QDC3 - QUADRO COMPOSTO POR

-01 DISJUNTOR 40A TRIPOLAR


-01 DISJUNTOR 20A TRIPOLAR

TAMPA EXTERNA
CORTE TAMPA QDC3 DISJUNTOR 20A TRIPOLAR TAMPA QDC3 -04 INTERRUPTORES P/CHAVE DE PARTIDA DIRETA
QDC 3 -04 LED VERMELHA P/MOTORES

-PLACAS DE IDENTIFICAÇÃO

EXAUSTOR 02 EXAUSTOR 03 EXAUSTOR 04 EXAUSTOR 05

EXAUSTOR 02 EXAUSTOR 03 EXAUSTOR 04 EXAUSTOR 05

1 4MM

3F 6 MM
1N 4MM

CABO PP 1,0MM -4 VIAS

CABO PP 1,0MM -4 VIAS

CABO PP 1,0MM -4 VIAS


CABO PP 1,0MM -4 VIAS
CHAVE DE PARTIDA DIRETA C/FUSIVEL DE PROTEÇÃO
01 P/CADA MOTOR

1 4MM
3F 6 MM
1N 4MM

1,5 CV 1,5 CV 1,5 CV 1,5 CV

ELABORADO POR
Mucio Nery Fabiano / Luciene Fabiano
Resp. Tecnico Layout

Você também pode gostar